This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
1260 - Regulatory (Subpart C or D), Net Ton
1260 - Regulatory (Subpart C or D), Gross Ton
Maury page id
psix-40805
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
EFFECT PERMANENT REPAIRS TO APPROX 4 INCH FRACTURE #2P WING VOID AT APPROX 7 FT DRAFT, APPROX 15 FT AFT OF FORWARD BULKHEAD PRIOR TO LOADING NEXT CARGO.
Condition: Unknown
Due 14 August 1991
Resolved 14 August 1991
Construction/Loadline
Issued 14 August 1991Resolved
EFFECT PERMANENT REPAIRS TO APPROX 1 INCH FRACTURE STBD STERN CORNER WRAPPER AT 7 FT DRAFT PRIOR TO LOADING NEXT CARGO.
Condition: Unknown
Due 14 August 1991
Resolved 14 August 1991
Construction/Loadline
Issued 9 March 1988Resolved
VESSEL IS TO PROCEED TO THE UNION CARBIDE PLANT IN TAFT, LA TO DISCHARGE THE PRESENT CARGO OF ETHYL ACRYLATE AND RETURN TO TT COATINGS, HARAHAN, LA TO BE GAS FREED AND MADE AVAILABLE FOR PERMANENT REPAIRS TO TWO PINHOLE LEAKS IN WAY OF THE STERN BOX. (46CFR31.10-15)
Condition: Unknown
Due 9 March 1988
Resolved 9 March 1988
Construction/Loadline
Issued 12 May 1987Resolved
RENEW #2 STBD. VOID VENT (VENT PIPE AND GOOSENECK FITTING) AT NEXT GAS-FREEAVAILABILITY BUT NOT LATER THAN 31JUL87.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Deck/Cargo
Issued 12 May 1987Resolved
CONDUCT OR SHOW PROOF OF ANNUAL CARGO PIPING TEST PRIOR TO LOADING CARGO BUT NOT LATER THAN 15 JUL 87.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Construction/Loadline
Issued 21 April 1987Resolved
RENEW #2 STBD VOID GOOSENECK VENT AND PIPE AT NEXT GAS FREE BUT NOT LATER THAN 31 JUN 87.
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987
Deck/Cargo
Issued 21 April 1987Resolved
CONDUCT OR SHOW PROOF OF ANNUAL CARGO PIPING TEST PRIOR TO TRANSFER OF CARGO BUT NOT LATER THAN 15 MAY 87.
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987
Construction/Loadline
Issued 22 April 1985Resolved
CROPPED OUT AND RENEWED 4'X9' SECTION OF BOTTOM AT THE TRANSITIONAL KNUCKLEIN #1P VOID, ABOUT 30' AFT OF FWD BHD.
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985
Deck/Cargo
Issued 22 April 1985Resolved
REPAIR OR REMOVE NITROGEN INJECTION SYSTEM.
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985
Construction/Loadline
Issued 27 March 1985Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGED AREA AT THE PORT DECK KNUCKLE IN #2P WING VOID AND TO THE 24" DECK KNUCKLE FRACTURE ON THE PORT SIDE OF THE BOW VOID AND TO THE 18" DECK KNUCKLE FRACTURE ON THE STBD SIDE OF THE BOW VOID.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 13 October 1983Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL USL 436, CG004598.
Condition: Unknown
Due 13 October 1983
Resolved 13 October 1983
Deck/Cargo
Issued 13 October 1983Resolved
HYDROSTATICALLY TEST CARGO PIPING TO AT LEAST 1.5 TIMES MAWP AND PROVIDE EVIDENCE OF SATISFACTORY TEST TO OCMI NEW ORLEANS, LA.
Condition: Unknown
Due 13 October 1983
Resolved 13 October 1983