MAURY USCG vessel records Sign in
← All vessels

CEDAR ISLAND

CEDAR ISLAND is a 1994 passenger vessel (inspected). The Coast Guard has recorded 190 inspections since 1994, most recently in July 2026, along with 130 deficiencies and 39 casualty investigations between 2006 and 2026.

Records from 1994 to 2026. Most recent: inspection, 6 July 2026.

Built
1994
Last inspected
6 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCP5499
408547
Flag
UNITED STATES
366986260
Maury page id
psix-408547

Inspections, by type

…with no type recorded46
Years with a record 31 calendar years (1994–2026)
The 190 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)207.8 ft × 38.0 ft × 12.5 ft
Registered tonnagegross 648 / net 295
ITC dimensions (L × B × D)207.8 ft × 38.0 ft × 12.5 ft
ITC tonnagegross 648 / net 295
BuilderMOSS POINT MARINE INC · ESCATAWPA, MS, UNITED STATES · built 1994
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMANNS HARBOR, NC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it499 - Displacement, Ton
648 - Convention (Subpart B), Gross Ton
295 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCP5499MMSI 366986260 · active · compulsorily equipped · granted 14 November 2024, expires 3 January 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LEXINGTON Industrial Vessel · MISLE 669860 · 29 January 2006 · activity 2576602

Inspection history · 190

6 July 2026 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8443614
25 March 2026 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8332183
20 March 2026 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8329291
18 March 2026 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8327579
22 February 2026 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8314589
22 February 2026 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8392616
16 February 2026 Administrative Inspection · Drydock Extension
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8312892
27 January 2026 Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8302334
10 December 2025 Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8280331
30 November 2025 Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8275165
30 October 2025 Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8261010
30 October 2025 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8359350
11 September 2025 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8231189
5 June 2025 Deficiency Check · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8144922
28 March 2025 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8101438
18 February 2025 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8080544
4 February 2025 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8074963
21 November 2024 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8038319
12 November 2024 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8037535
13 September 2024 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8001999
10 September 2024 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7999157
30 August 2024 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7992955
10 August 2024 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7978537
13 June 2024 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7932322
22 April 2024 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7922719
20 March 2024 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7881911
21 January 2024 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7852198
6 December 2023 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7834323
27 November 2023 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7830685
14 September 2023 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7785843
21 August 2023 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7773653
19 July 2023 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7746717
19 July 2023 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7821539
14 June 2023 COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7700651
20 March 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7654834
17 January 2023 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7622440
8 December 2022 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7606123
27 October 2022 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7580231
26 October 2022 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7584003
13 September 2022 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7557888
15 August 2022 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7534553
28 July 2022 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7517534
12 July 2022 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7504770
12 July 2022 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7504855
29 June 2022 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7490491
15 June 2022 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7478178
19 May 2022 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7455222
2 May 2022 Special
Type not classified · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7442570
14 April 2022 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7425720
20 January 2022 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7367988
27 October 2021 Re-Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7338950
22 July 2021 Deficiency Check · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7263018
28 April 2021 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7184036
6 February 2021 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7137001
4 February 2021 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7140017
1 February 2021 MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7134365
18 September 2020 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7065078
17 July 2020 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7011548
17 July 2020 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7013963
13 July 2020 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7005066
13 July 2020 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7012092
22 June 2020 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6987098
19 May 2020 COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6955740
18 March 2020 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6897289
26 February 2020 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6952604
23 February 2020 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6914240
23 February 2020 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6917396
11 December 2019 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6836309
28 November 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6864534
28 November 2019 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6867406
19 September 2019 Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6741548
15 July 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6752616
14 July 2019 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6753227
16 May 2019 MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6663932
15 November 2018 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6566354
21 October 2018 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6572049
30 September 2018 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6575361
16 August 2018 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6449649
3 June 2018 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6433056
3 June 2018 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6452190
19 April 2018 Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6373226
21 February 2018 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6358510
6 December 2017 Periodic Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6319669
18 October 2017 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6265249
20 September 2017 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6270990
17 September 2017 Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6269281
6 July 2017 Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6199328
17 May 2017 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6148193
14 December 2016 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6033369
30 August 2016 COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5987915
26 July 2016 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5952249
24 July 2016 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5959884
6 July 2016 Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5908539
6 April 2016 Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5828513
24 January 2016 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5802801
20 January 2016 Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5756953
10 October 2015 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5757174
22 September 2015 Deficiency Check · COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5725808
13 July 2015 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5183841
9 October 2014 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5002428
12 August 2014 Examination of Repairs · Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4952217
1 May 2014 Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4848300
26 March 2014 COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4794481
13 June 2012 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4343923
12 June 2012 Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4308153
1 February 2012 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4236247
19 September 2011 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4157563
12 September 2011 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4154623
19 August 2011 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4123630
1 August 2011 Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4102137
25 January 2011 COI Inspection · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3932382
8 December 2010 Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3906564
4 October 2010 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3863502
11 March 2010 MTSA Verification · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3693824
27 March 2009 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3442580
22 March 2009 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3437848
11 March 2009 COI Inspection · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3430456
7 March 2009 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3430096
28 February 2009 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3426255
14 February 2009 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3418761
15 January 2009 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3396749
17 December 2008 Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3382158
23 October 2008 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3350562
17 September 2008 Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3330762
19 July 2008 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 3275648
27 April 2008 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3196541
10 March 2008 COI Inspection · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3161413
26 October 2006 COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2891425
24 October 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2821555
16 September 2006 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2779785
8 September 2006 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2772791
16 March 2006 Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2606453
7 February 2006 Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2580563
29 January 2006 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2576602
26 January 2006 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2576130
26 October 2005 COI Inspection · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2516900
18 January 2005 COI Inspection · MTSA Verification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2276600
9 November 2004 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2259354
4 February 2004 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2002803
8 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1961087
6 February 2003 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1740703
17 October 2002 Periodic Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1693956
13 May 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1616194
13 March 2002 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1492987
17 January 2002 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1479843
21 November 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 772819
27 September 2001 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1435283
19 June 2001 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1472063
15 March 2001 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1449438
15 June 2000 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1413754
22 March 2000 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 816537
16 March 2000 COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1420265
4 November 1999 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1418621
4 August 1999 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1421735
1 July 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 72145
3 May 1999 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1390999
11 February 1999 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1471183
16 November 1998 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1430610
10 August 1998 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1131313
11 May 1998 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 791079
14 April 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 151811
11 February 1998 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1416641
17 September 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 702551
8 September 1997 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1121832
23 August 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 786070
18 August 1997 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 784405
15 August 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 213218
19 March 1997 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1407851
3 March 1997 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 774540
13 February 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 56246
10 December 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 80969
2 December 1996 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 875999
28 September 1996 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 834279
25 September 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 37334
16 September 1996 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1269642
3 June 1996 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1087513
28 May 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 118060
4 April 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 151533
7 March 1996 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1080197
7 December 1995 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 876625
9 November 1995 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 876835
29 September 1995 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 873554
13 September 1995 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1183495
8 June 1995 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 876256
16 May 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 42987
17 April 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 53508
4 April 1995 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 841623
30 January 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1150051
10 January 1995 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 862258
12 December 1994 Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1419358

Deficiency record · 130

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 February 2026 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter. It was report that the port MDE had a ruptured expansion joint causing the J/W to drain into the bilge and therefor had to secure the MDE. Conduct repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2026
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 10 December 2025 Resolved
Each hand portable fire extinguisher shall be marked with a number and the location where stowed shall be marked with a corresponding number at least 1/2 inch high. Where only one type and size of hand portable fire extinguisher is carried, the numbering may be omitted. Stations #6 & #10 were missing numbers. Replace missing numbers to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2026
Resolved 27 January 2026
Resolution: New labels installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 October 2025 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness. CG was notified with vessel loss of steering while trying to back out of terminal. Conduct repairs, test and conduct satisfactory sea trials to the satisfaction of USCG prior to carrying passengers.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2025
Resolution: Replaced O-rings on crossover valves on steering block
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 June 2025 Resolved
The lights prescribed in these rules shall have an intensity as specified in Annex I to these rules, so as to be visible at the minimum ranges. Vessels of 50 meters or more in length must have a white all around light for 3 miles. All around white light was found with one light not working and the 2nd all around light working, the off with an alarm at helm station and then flickering. Make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2025
Resolved 2 July 2025
Resolution: Replaced receptacle and plug. Test SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 November 2024 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness. CG was notified stating the port clutch was banging/thumping every time clutching in. Conduct repairs, test and conduct satisfactory sea trials to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2025
Resolution: Transmission was removed for overhaul and inspection. No failures within transmission found. Determined alignment to shaft was cause of issue. Transmission was overhauled, shipyard realigned transmission and engine to shafting. Conducted SAT sea trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 September 2024 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness. CG was notified stating the starboard clutch was banging/thumping every time clutching in going reverse. Conduct repairs, test and conduct satisfactory sea trials to the satisfaction of attend CG Marine Inspector prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2024
Resolution: Witnessed underway propulsion test following installation of new port and stbd reduction gears; all sat.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 August 2024 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness. MI was notified stating vessel was struck by lightening. Multiple electronics have been affected. Repair or replace with in-kind equipment and make available for attending MI.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 August 2024
Resolution: NCDOT Maintenance replaced equipment and tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 August 2024 Resolved
Electric installations on vessels must ensure maintenance of services necessary for safety under normal and emergency conditions. Vessel lost power on #1SSDG for approximately 20 seconds during transit. Prove proper operation of #1SSDG to satisfaction of CG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2024
Resolved 10 August 2024
Resolution: CG was provided statement from master regarding shoreside maintenance. DMI spoke with shoreside maintenance and problem could not be replicated; all systems and sensors tested within normal operating parameters.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 13 June 2024 Resolved
The Type II retro-reflective material approved under approval series 164.018 must be placed on the boat to meet the arrangement requirements in IMO Resolution A.658(16). Renew retro-reflective tape on rescue boat. Tape was found missing peeling off.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 20 June 2024
Resolution: Retro-reflective tape was renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 13 June 2024 Resolved
The inspection shall be such as to insure that the vessel, as regards to life-saving appliances and other equipment is in satisfactory condition and fit for the service for which it is intended. A minor leak found on hydraulic accumulator for the rescue boat davit. Make effective repairs IAW manufacture instructions.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 20 June 2024
Resolution: The fitting was leaking at the bottom of the accumulator. The fitting was replaced and operational test conducted.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 13 June 2024 Resolved
At each annual inspection, the inspector shall examine the tank tons and bilges in the machinery spaces to see that there is no accumulation of oil which might create a fire hazard. Excessive accumulation of oil and water mixture was discovered in the bow thruster space bilges during the inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 20 June 2024
Resolution: The bilges were cleaned by the crew.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 March 2024 Resolved
The installation of all systems of a marine engineering nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter F (Marine Engineering) of this chapter. MI discovered signs of multiple coolant leaks (crystalized coolant) on main engines and ship service generators. Provide local OCMI proposed repair plan and/or findings.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2024
Resolved 20 June 2024
Resolution: Gasket replaced. Verified during recent inspection that the leak was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 January 2024 Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. Trouble shoot and determine the cause of the inoperative #2 SSDG breaker, found during morning boat checks while out of service. Provide findings in regards, make proper repairs, and conduct satisfactory operational test to the satisfaction of the Coast Guard.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 January 2024
Resolved 21 January 2024
Resolution: Faulty breaker was renewed and tested by the crew.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 November 2023 Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. Trouble shoot and determine the cause of the starboard engines, clutch noise that was noted during mooring at Cedar Island, make proper repairs to the satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 November 2023
Resolved 27 November 2023
Resolution: Changed out and retorqued three coupling bolts on the output shaft of reduction gear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 September 2023 Resolved
Bilge system must be capable of pumping from any watertiht compartement. Vsl #1 port void bilge suction is inop. Vsl Must provide bilge pumping capabilities iaw this part.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 September 2023
Resolution: NCDOT Maintenance dept broke check valve loose test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 August 2023 Resolved
BILGE PIPING MUST BE CAPAPLE OF PUMPING FROM AND DRAINING ANY WATERTIGHT COMPARTMENT. VSL SELF REPORTED A 1/4" HOLE IN THE SUCTION SIDE OF THE MAIN BILGE SYSTEM. VSL MUST PROVIDE PIPING CAPABLE OF PUMPING AND DRAINING WATER FROM ANY WATERTIGHT COMPARTMENT IAW THIS PART. 46 CFR 56.50-50
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2023
Resolution: Bilge piping repaired in Mann's Harbor inspected by Nags Harbor MI. Tested to 50 psi. Reinstalled by NCDOT maint div in Ocracoke, NC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 July 2023 Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. Crew reported a loss of electrical power on the vessels #1 SSDG, while in service. Trouble shoot, make proper repairs, and report findings to the satisfaction of the local marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2023
Resolved 19 July 2023
Resolution: Identified defective voltage regulator on SSDG. The part was replaced in-kind and tested satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2022 Resolved
Operating generators must provide continuous and uninterrupted source of power for the ship's service load under normal operational conditions. Master reported no voltage on #2 service generator rendering inoperable. Make permanent repairs to the satisfaction of the attending Marine Inspector. Vessel authorized one time transit to Cedar Island Terminal with no passengers for repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 December 2022
Resolved 8 December 2022
Resolution: NCDOT C/I Maintenace replaced motor end of #2SSDG, Tested system, all SAT
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 13 September 2022 Resolved
PASSENGER VESSELS OVER 500GT MUST CARRY ON EACH SIDE OF THE VESSEL AT LEAST ONE RESCUE BOAT. VSL HAS ONLY ONE RESCUE BOAT INSTALLED. VSL MUST PROVIDE SECOND RESUCE BOAT OR AN APPROVED EXEMPTION LETTER FROM THE OCMI. 46 CFR 199.202
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 4 October 2022
Resolution: Rcvd approval letter from PDH
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 28 July 2022 Resolved
The hull, structual bulkheads, decks, and deck houses shall be constructed of steel or other equivalent metal construction of appropriate scantlings. Vessel has temp repair on bulkhead in EDG space. Permanent repairs must be conducted to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2022
Resolved 15 May 2023
Resolution: Extended to NLT completion of credit drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 July 2022 Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. The crew reported a loss of electrical power on the #2 ships diesel generator, while underway enroute with passengers and vehicles to Ocracoke. Trouble shoot and make proper repairs to the satisfaction of the Coast Guard.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 12 July 2022
Resolved 12 July 2022
Resolution: The company carried out troubleshooting to the satisfaction of the Coast Guard. See AN 7504770 for further details.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 12 July 2022 Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. The crew reported the vessel's emergency diesel generator subsequently did not take the vessel's electrical load as design, upon loss of the normal electrical load.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 12 July 2022
Resolved 12 July 2022
Resolution: The company carried out troubleshooting to the satisfaction of the Coast Guard. See AN 7504770 for further details.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 June 2022 Resolved
Each self propelled vessel must have both main and auxiliary steering gear, except when the main steering gear includes two or more identical power units. Master reported the #2 steering system kicked out to 0 degrees when they passed 35 degrees to port. Make permanent repairs to steering system. Provide technician's report of findings and repair. Prove proper operation of steering system to USCG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 29 June 2022
Resolved 29 June 2022
Resolution: Technician found the camshaft in the steering feedback box for the #2 system was out of sync 180 degrees. After adjusting, satisfactory operational tests were conducted. No further issues.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 15 June 2022 Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. During morning checks the crew discovered the vessel's emergency diesel generator was not taking the ships electrical load as designed. Trouble shoot and determine the cause, make proper repairs to the satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2022
Resolved 15 June 2022
Resolution: Replaced starter relay. Satisfactorily tested egen.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 May 2022 Resolved
All installations shall be of marine type engines suitable for the intended service, design, and constructed in conformance with the requirements of this subchapter. A fuel leak was detected on starboard main engine fuel filter housing appox. 1/2" cracked weld was cause of casualty. Make effective repairs and prove proper operation to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2022
Resolved 19 May 2022
Resolution: Company provided objective evidence the fuel filter housing was replaced in-kind and operationally tested to the satisfaction of the Coast Guard. See AN7455222
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 January 2022 Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he/she deems necessary to be assured of the safety of the vessel. Perform operational tests of the fixed fire extinguishing systems IAW table 46 CFR 71.25-22(a)(2) in the presence of the attending Marine Inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2022
Resolved 4 February 2022
Resolution: Witnessed satisfactory operational test on all fixed fire fighting systems onboard. Time delay popped off at 31 seconds.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 20 January 2022 Resolved
The installation of all systems of a marine engineering nature with details with details of installation shall be in accordance with the requirements of sub-chapter F. The starboard generator lube oil hose IVO gauge is wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 4 February 2022
Resolution: Lube oil hose for stbd generator was renewed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 January 2022 Resolved
It shall be the duty of the owner , master or person in charge to see that the vessel's firefighting equipment is maintained. #19 portable CO2 in the engine room has worn out hose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 4 February 2022
Resolution: Hose for #19 CO2 was replaced with new.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 20 January 2022 Resolved
Each credentialed crewmember must become familiar with the relevant characteristics of the vessel's fire fighting systems. Chief engineer was not familiar with the engine room fixed fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 January 2022
Resolved 20 January 2022
Resolution: Fixed fire extiguisheing systems traing was conducted with Chief Engineer. Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 January 2022 Resolved
Bilge pumping plant must be capable of pumping from any watertight compartment. During operational test of the engine room, bilge suction crossover valve was found open.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 20 January 2022
Resolved 20 January 2022
Resolution: The crossover valve was closed and the system was found fully operational after test was conducted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 November 2021 Resolved
Vessels contracted for prior to January 18, 2017, must meet the following requirements: (1) Previously installed extinguishers with extinguishing capacities smaller than are required in Table 76.50-10(a) of this subpart need not be replaced and may be continued in service so long as they are maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection; and (2) All new equipment and installations must meet the applicable requirements in this subpart for new vessels. During an expanded examination, the attending inspector discovered eleven (11) fire-extinguishers, that were manufactured after the applicable date and did not have previous identification IAW the vessel Certificate of Inspection. These fire extinguishers do not meet the new classification system required by regulation. Provide change out plan and or renew the fire-extinguishers on board to comply with the regulations of table 76.50-10(a) and to the satisfaction of the Coast Guard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2021
Resolved 2 November 2021
Resolution: All CO2 extingusihers in question that were installed with a manufacture date after the applicable date of 18 Jan 2017 were replaced. The new list was submitted and verified by the attending Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 October 2021 Resolved
All emergency lights shall be marked with a letter "E" at least 1/2 inch high. All emergency light on upper passenger deck are fade or painted over.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 27 October 2021
Resolution: All emergency light properly re-labeled with "E" letters 1/2 inch.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 27 October 2021 Resolved
In all ventilation systems dampeners provided be served by the systems for shutting off the passage of air in the event of fire. Ventilation shutdown switch for bow thruster space was found rigged in closed position.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 October 2021
Resolution: Rig removed and added proper shims to properly close switch.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 July 2021 Resolved
Before vessel leaves port and at all times during the voyage each life saving appliance must be in working order and ready for immediate use. During spot check M/I noted a wasted life ring buoy and two float lights with defective batteries not being maintain properly by crew.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 July 2021
Resolved 22 July 2021
Resolution: The crew replaced two ring buoys, properly marked, and two float light batteries to the satisfaction of the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 28 April 2021 Resolved
Rescue boat davit hydraulic reservoir small drop of fluid at the spot weld. ID cause. MI observed for 90 mins and could not duplicate.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 12 May 2021
Resolution: Reservoir was replaced with spare and tested.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 28 April 2021 Resolved
Passenger compartment to galley ladder handrail loose.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 28 April 2021
Resolution: Hardware tightened.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 28 April 2021 Resolved
Bowthruster lagging improperly installed. Causing a burn/fire haz.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 10 May 2021
Resolution: Lagging was properly installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 28 April 2021 Resolved
Properly install tank room overhead hatch gasket.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 10 May 2021
Resolution: Gasket was properly re-attached.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 April 2021 Resolved
Reinstall spot light cover gasket.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 28 April 2021
Resolution: Gasket properly installed
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 February 2021 Resolved
Fixed firefighting system (CO2 bottles and local actuation) for bow thruster is located within the bow thruster space. Provide evidence of prior USCG approval or modify arrangement to ensure bottles are not located inside space iaw 46 CFR 76.15-20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2021
Resolved 4 February 2021
Resolution: Verified approved plans that allowed CO2 bottles to be located in the bow thruster space.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 February 2021 Resolved
Actuation for engine room fixed firefighting is located within engineering space. Provide evidence of prior USCG approval or modify arrangement to ensure remote actuation is not located inside space iaw 46 CFR 76.15-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2021
Resolved 8 February 2021
Resolution: Approved drawings allowed CO2 bottles within the engineering spaces. Verified that the remote acuation is located outside the space.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 1 February 2021 Resolved
Ensure all portable fire extinguishers are in approved locations in accordance with 46 CFR 76.50-10 TABLE and provide evidence of servicing of semi-portable extinguisher iaw 46 CFR 76.50-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2021
Resolved 9 February 2021
Resolution: Reviewed fire control plan was approved and MI's verified fire extinguishers against table. Verified semi-portable was properly serviced.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 1 February 2021 Resolved
Update fire control plan as needed iaw 46 CFR 71.65-5(d)(6)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2021
Resolved 8 February 2021
Resolution: Verified approved fire control plan.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 1 February 2021 Resolved
Install low lube oil alarm for bow thruster and provide associated audible/visual alarm is installed in the engineering booth iaw 46 CFR 62.35-50 and 46 CFR 62.25-30(b)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2021
Resolved 3 March 2021
Resolution: Low lube oil alarm for bow thruster installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 February 2021 Resolved
Submit updated electrical plans to MSC for approval for newly installed wiring/alarms on bridge from engine room, aft steering to control booth, and bow thruster to engineering booth iaw 46 CFR 70.65-10 and 46 CFR 71.55-1.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2021
Resolved 3 March 2021
Resolution: Plans submitted to the MSC
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 1 February 2021 Resolved
Replace/repair broken watertight door indicator iaw 46 CFR 170.270(e).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 February 2021
Resolved 11 February 2021
Resolution: Replaced watertight door indicated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 July 2020 Resolved
Master reported high compression on the starboard engine. A requirement was issued to determine cause and report findings to the coast guard inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 July 2020
Resolved 18 July 2020
Resolution: Filters were changed which had caused restriction and high crankcase pressure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 July 2020 Resolved
Captain reported oil leaking from the starboard main engine block to Coast Guard. All repairs are to be made to the satisfaction of the attending Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2020
Resolution: Maintenance crew found #7 cylinder was scorched, piston head cracked,and outboard turbo charger near #7 cylinder in early stages of bearing failure. Maintenance crew replaced cylinder, piston, head, injector, oil jet, and both turbo chargers. All tests SA
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 4 June 2020 Resolved
The vessels chief engineer license did not meet the conditions of the manning per the COI. License presented - stated in limitations motor propelled for less than 500 GT, vessel is greater than 500. Provide prove of proper manning within 90 days, per CPREV's direction.
Action required: 705 - Other - as specified
Due 4 August 2020
Resolved 18 June 2020
Resolution: The OCMI by direction, rescinded the requirement until further final detemination can be made.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 4 June 2020 Resolved
Upon arrival to vessel all doors and windows were observed open due to A/C inoprative. After checking engineering logs A/C has been having problems since Dec 2019 and currently isnt working due to compressor issue.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2020
Resolved 30 July 2020
Resolution: New compressor installed and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 June 2020 Resolved
Rescue boat port bow gel coat cracks in several areas above rub rail. Sand and repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 June 2020
Resolution: Gel coat now repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 4 June 2020 Resolved
Rescue boat davit hydro tank spacers wasted and must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 June 2020
Resolution: Spacers replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 4 June 2020 Resolved
MIs noted hole in the E-Gen aft bulkhead due to corrsion. Temp repair will be made until dry-dock dated 31 Jul 2020.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 June 2020
Resolution: E-Gen bulkhead corrosion now repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 June 2020 Resolved
#11 main deck fire ext. missing safety pin.
Action required: 10 - Deficiency Rectified
Resolved 4 June 2020
Resolution: New pin installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 4 June 2020 Resolved
Bow thruster thur hull auto valve leaking sea water into vessel when operating. Vessel must correct prior to passengers this may require dry-dock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2020
Resolution: Bow thruster butterfly valve now replaced, all associated piping tested and found sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 June 2020 Resolved
DUplex sea strainer for A/C untit from seachest not functioning properly causing the valve to leak by. Replace valve with new.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 June 2020
Resolution: Valve was overhauled at the shipyard, now working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 June 2020 Resolved
Steering rams leaking port and stbd. MIs noted drip pans and rags under steering rams. This will be correccted in the 31Jul dry-dock
Action required: 705 - Other - as specified
Resolved 29 June 2020
Resolution: Steering ram overhauled/replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 June 2020 Resolved
E-gen vent screen not properly installed/ pushed in.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 June 2020
Resolution: E-gen screen now repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 4 June 2020 Resolved
Hot water heater wasted. Replaced water heater and mounts.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 June 2020
Resolution: Hot water heater now replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 4 June 2020 Resolved
Potable water head tank wasted at bottom and mounts.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 June 2020
Resolution: Shipyard repaired wasted area/valve.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 June 2020 Resolved
Water tight doors to a/c room and main deck to bow thruster room losse dogs were noted. Tighten and rechaulk test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2020
Resolution: Chalk tested doors, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 18 March 2020 Resolved
Rescue boat would not start. Problem found, adjust netural so vessel will start.
Action required: 10 - Deficiency Rectified
Resolved 18 March 2020
Resolution: Adjusted safety switch and linkage tested SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 18 March 2020 Resolved
Crew passage way hall lighting lights were 100% out. Install new light bulbs.
Action required: 10 - Deficiency Rectified
Resolved 18 March 2020
Resolution: New light bulbs installed and tested SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 March 2020 Resolved
Life jacket stowage boxes upper deck found to have broken hinges and rivots.
Action required: 10 - Deficiency Rectified
Resolved 18 March 2020
Resolution: New rivots installed and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 19 June 2019 Resolved
The rescue boat davit pin retaining clips on craddle were wasted and damaged.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 19 June 2019
Resolved 19 June 2019
Resolution: Crew changed out all clips with new hardware to the satisfaction of the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 19 June 2019 Resolved
The rescue boat port and starboard side life lines are worn and wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2019
Resolved 27 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 19 June 2019 Resolved
The galley and crew berthing has loose tiles which are damaged and creating a slip and tripping hazard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 27 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 19 June 2019 Resolved
The ladder well stairs has loose ladder treads.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 27 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2019 Resolved
The bow entrance to passenger compartment overhead emergency light has water and filled with insect.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 27 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 June 2019 Resolved
The main deck life ring buoy line is not properly installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 27 June 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 June 2019 Resolved
The fire pump has metal shaving in the bilge area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2019
Resolved 27 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 June 2019 Resolved
Both MDE's and SSDG's resilant mounts for gauges are damaged.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2019
Resolved 27 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 June 2019 Resolved
The port side main engine shaft seal cooling pump is inoperative.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 19 June 2019
Resolved 19 June 2019
Resolution: Crew trouble shoot the pump and proved proper operation to satisfaction of the attending inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 19 June 2019 Resolved
The pilot house air handler has an unusal noise vibration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2019
Resolved 27 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 June 2019 Resolved
Both MDE's have damaged gauges (on local box)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2019
Resolved 27 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 June 2019 Resolved
The #1 SSDG gauge panel has two open hole in the panel.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 27 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 June 2019 Resolved
The #1 SSDG overspeed and emergency stop is inoperative.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2019
Resolved 19 June 2019
Resolution: Crew trouble shot and proved proper operation to the satisfaction of the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 19 June 2019 Resolved
Conduct satisfactory sea trials and drills.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2019
Resolved 27 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 June 2019 Resolved
The MDE port shaft seal cooling gauge is inoperative.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 19 June 2019
Resolved 27 June 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 June 2019 Resolved
The aft stern light is not displaying the proper arc (lens is shifted) Prior to night operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2019
Resolved 27 June 2019
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 15 November 2018 Resolved
Unclog condensate drain lines IWO crew quarters
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2018
Resolved 13 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 August 2018 Resolved
Repair erratic shaft tach operation P&S
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2018
Resolved 17 August 2018
Resolution: Report from NCDOT both tachs repaired.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 3 June 2018 Resolved
STBD shaft leaking approx. 2 GPM due to shaft seal and fwd to aft movement of shaft.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 July 2018
Resolved 5 June 2018
Resolution: Used coupling installed on output shaft of marine gear. Shaft aligned. MI verified.
Fire Fighting › Fire Main › Condition
Issued 17 September 2017 Resolved
The discharge side of Fire Pump #2 has a pin hole leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2017
Resolved 19 October 2017
Resolution: Pipe cropped and renew. All test SAT.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 19 July 2017 Resolved
Found an exhaust leak on the #2 MDE IWO the exhaust silencer flange. Renew the exhaust gasket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 17 April 2018
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 19 July 2017 Resolved
Unable to test/ verify the low lube oil alarms on #1 MDE, #2 MDE, and the Bow Thruster. Install fittings to facilitate test.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2021
Resolution: Test sat
Engineering › Fuel Oil Service System › Filter
Issued 15 March 2017 Resolved
Verify proper operation of fuel filter/separator differential pressure guages (MSD space fuel unit). Verify proper operation of fuel check valve (before the primary racors) IWO #1 generator. The above requirements are due to the #1 generator becoming airbound due to clogged remote primary fuel filters.
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 19 July 2017
Resolution: Verified proper operation of the fuel system and installation of new differential pressure gauges on the fuel filter/separator located in the MSD space.
Construction/Loadline › Hull › Weld
Issued 24 January 2016 Resolved
Attending Inspectors noted fractured weldment IWO port quarter main deck stanchion along with buckled bulwark(s).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 16 August 2016
Resolution: resolved
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 19 October 2015 Resolved
Provide the vessel with Periodic Safety Test Procedures (PSTPs) for the control and monitoring systems associated with 46 CFR Part 62 in accordance with 46 CFR 61.40.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 10 August 2021
Resolution: See MISLE Activity 7134365 and MSC PTSP approval letter Serial No. E2-2100409 dated February 23, 2021.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 19 October 2015 Resolved
Verify proper operation of required low lube oil pressure alarm and shutdown on both main diesel engines.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 19 July 2017
Resolution: As per CVC's letter (Serial No. 1199) vessel is not required to have lube oil shutdowns.
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 October 2015 Resolved
Install a bilge alarm system in accordance with 46 CFR Part 62 (Table 62.35-50) no later than the next drydock.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 29 September 2016
Resolved 19 July 2017
Resolution: Following an appeal by NCDOT, CVC determined vessel was not required to install a bilge alarm system.
Engineering › Freshwater Generation System › Heating Tube
Issued 18 June 2014 Resolved
Renew electric hot water heater IWO STBD Auxiliary Machine Space (bottom of hot water tank wasted)
Action required: 705 - Other - as specified
Due 18 June 2014
Resolved 30 June 2014
Resolution: It was determined that the outer shell of the water heater tank was waisted and not the inner tank it self. Wasted area of water heater tank was cleaned and painted. Deficiency corrected to the satisfaction of the Marine Inspectors.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 26 March 2014 Resolved
Attending inspector noted that the emergency steering instructions located in the engine room were faded/unreadable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 24 September 2014
Fire Fighting › Remote Fuel Shutoff › General
Issued 26 March 2014 Resolved
Attending inspectors noted that the emergency fuel shutoff valve for the emergency diesel generator was not fitted with positive stops.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 24 September 2014
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 26 March 2014 Resolved
Attending inspectors noted that the portable CO2 extinguisher @ Station #5 was severely wasted and in need of replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 24 September 2014
Lifesaving › Lifebuoys › Serviceable
Issued 26 March 2014 Resolved
Attending inspectors noted that the ring life buoy was damaged IWO becket holes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 24 September 2014
Lifesaving › Rescue Boat Equipment › Painter
Issued 26 March 2014 Resolved
Attending inspectors noted that the painter line and stern line (steel rings) were in need of repair/replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 24 September 2014
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 June 2012 Resolved
Repair STBD side light due to broken lens.
Action required: 705 - Other - as specified
Due 25 June 2012
Resolved 26 September 2012
Resolution: Attending inspectors verified condition and operation of navigation light lens.
Stability › Intact Righting Energy › General
Issued 12 June 2012 Resolved
Provide updated stability letter and post. Vsl added fixed balllast FWD and AFT.
Action required: 705 - Other - as specified
Due 13 June 2012
Resolved 26 September 2012
Resolution: Attending inspectors verified vessels stability letter.
Engineering › Bilge Water Management System › Pump
Issued 12 June 2012 Resolved
Bolt down the #2 A/C raw water cooling pump.
Action required: 705 - Other - as specified
Due 15 June 2012
Resolved 26 September 2012
Resolution: Attending inspectors verified repairs made to #2 A/C R/W cooling pump.
Lifesaving › Rescue Boat › Construction
Issued 12 June 2012 Resolved
Repair damaged FRP IWO STBD chine (holed) due to contact with cradle ladder. Make temp repairs then send out to a servicing facility.
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 3 January 2013
Resolution: Attending inspectors verified repairs made to vessels rescue boat.
Communications › Radio Communications › VHF Radiotelephone
Issued 25 January 2011 Resolved
Repair port VHF radio (not transmitting clearly).
Due 30 March 2011
Resolved 29 June 2011
Engineering › Compressed Air System (start air) › Valve
Issued 25 January 2011 Resolved
Bench test relief valve IWO #2 compressor. The R/V appears to be relieving @ 220vs 250 psi.
Action required: 705 - Other - as specified
Due 30 March 2011
Resolved 29 June 2011
Stability › Intact Stability (when using lifting gear) › General
Issued 22 December 2010 Resolved
Vessel crew had unlawfully pumped ballast water into the foward and aft voids. In order to have a better ride which is a direct violation of the Stability letter.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 December 2010
Resolved 22 December 2010
Resolution: Vessel crew pumped out voids in the prescense of a Coast Guard Marine Inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 8 December 2010 Resolved
Local shut down on the Port side Main enigne was inop
Due 1 January 2011
Resolved 16 March 2011
Fire Fighting › Ventilation Systems › Operating Controls
Issued 8 December 2010 Resolved
Auto shutdown on the the Ventilation for the Emergency Diesel generator was inop.
Due 1 January 2011
Resolved 16 March 2011
Engineering › Bilge Water Management System › Piping
Issued 19 July 2008 Resolved
Make permanent repairs to holed no. 2 bilge suction pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2008
Resolved 17 December 2008
Resolution: Permanent repairs were made.
Fire Fighting › Fire Pumps › Pressure
Issued 16 March 2007 Resolved
Install relief valve on fire pump IAW 46 CFR 76.10-5(d) or prove under shutoff conditions that the fire pump is not capable of developing a pressure exceeding 125 psi.
Action required: 705 - Other - as specified
Due 31 March 2007
Resolved 21 March 2007
Resolution: NCDOT Ferry Division verfied through the manufacturer that the fire pump in the shutoff condition would operate properly up to 160 psi. No relief valve required.
Engineering › Non-conventional Propulsion/Steering › Motor Controller/Frequency Converter (Azipod)
Issued 16 March 2007 Resolved
Replace port MDE mother board.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2007
Resolved 17 March 2007
Resolution: NCDOT installed a new mother board on the port MDE, all sat.
Electrical › Electric Generation Source (emergency)
Issued 9 February 2004 Resolved
DEMONSTRATE PROPER OPERATION OF PRIMER MOVER LUBE OIL SHUTDOWN.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2004
Resolution: ADJUSTED SENSOR AND SATISFACTORILY DEMONSTRATED.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 9 February 2004 Resolved
DEMONSTRATE PROPER OPERATION OF STBD MPDE OVERSPEED TRIP.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2004
Resolution: REPLACED WORN GEAR, ADJUSTED AND SATISFACTORILY DEMONSTRATED.
Lifesaving
Issued 21 November 2001 Resolved
WEAK LINKS MISSING FROM ALL FIVE (5) IBS's.
Condition: Unknown
Due 5 December 2001
Resolved 5 December 2001
Fire Fighting
Issued 7 December 1995 Resolved
PRIOR TO THE VESSEL OPERATING WITH PASSENGERS, DEMONSTRATE PROPER OPERATIONOF FIXED CO2 SYSTEM TIME DELAY.
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Engineering
Issued 7 December 1995 Resolved
REPAIR/REPLACE PRESSURE RELIEF VALVE ON #1 AIR RECEIVER DUE TO INABILITY TOSELF-SEAT.
Condition: Unknown
Due 7 December 1995
Resolved 8 December 1995
Navigation
Issued 7 December 1995 Resolved
PROVIDE DEVIATION TABLE AND ILLUMINATION FOR MAGNETIC COMPASS OR REMOVE MAGNETIC COMPASS FROM VESSEL.
Condition: Unknown
Due 8 December 1995
Resolved 8 December 1995
Fire Fighting
Issued 9 November 1995 Resolved
INSTALL AUX FIRE PUMP VENT LINE IN ACCORDANCE WITH U. S. COAST GUARD APPROVED PLANS.
Condition: Unknown
Due 16 November 1995
Resolved 16 November 1995
Fire Fighting
Issued 13 September 1995 Resolved
PROVIDE WRITTEN DETAILS OF MODIFICATION TO AUXILIARY FIRE PUMP LOCATED IN BOW THRUSTER ROOM WHERE PUMP/SEA CHEST VENT LINES INSTALLED. REQUIREMENT TO BE COMPLETED NLT 30SEP95.
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Engineering
Issued 4 April 1995 Resolved
PROVE PROPER OPERATION OF BOTH MDE OVERSPEED TRIPS.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Electrical
Issued 4 April 1995 Resolved
PROVE PROPER OPERATION OF THE LUBE OIL SHUTDOWN AND HIGH TEMP ALARM FOR BOTH SSG'S.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Accommodation/Occupational Safety
Issued 4 April 1995 Resolved
IDENTIFY AND MARK VENT CLOSURES FOR THE MSD AND BOW THRUSTER SPACES.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Engineering
Issued 4 April 1995 Resolved
REPAIR FAULTY CHECK VALVE FOR #1 SHIPS AIR COMPRESSOR.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Navigation
Issued 4 April 1995 Resolved
REPAIR LEAKING STEERING DIRECTION CONTROL VALVE IN #1 SYSTEM.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Engineering
Issued 4 April 1995 Resolved
PROVE PROPER OPERATION OF THE CONTROL AIR LOW PRESSURE ALARM.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Lifesaving
Issued 12 December 1994 Resolved
CONDUCT REQUIRED DRILLS. 46CFR78.17-50
Condition: Unknown
Due 7 April 1995
Resolved 7 April 1995
Construction/Loadline
Issued 12 December 1994 Resolved
PROVIDE APPROVED DRAWING NC 240-0061, BILGE PIPING (RETURNED FOR REVISION)
Condition: Unknown
Due 11 January 1995
Resolved 10 February 1995
Navigation
Issued 12 December 1994 Resolved
RESOLVE OUTSTANDING MSC LETTER COMMENT CONCERNING CAST IRON DIRECTIONAL CONTROL. GMSC-2 LETTER E1-9400676 DTD 15APR94.
Condition: Unknown
Due 7 April 1995
Resolved 7 April 1995
Navigation
Issued 12 December 1994 Resolved
DEMONSTRATE SATISFACTORY OPERATION OF REMOTE/PORTABLE STEERING UNIT.
Condition: Unknown
Due 11 January 1995
Resolved 6 January 1995
Fire Fighting
Issued 12 December 1994 Resolved
PROVIDE REQUIRED DOCUMENTS (STATION BILL). 46CFR78.13-1
Condition: Unknown
Due 7 April 1995
Resolved 7 April 1995
Lifesaving
Issued 12 December 1994 Resolved
PROVIDE APPROVED/ACCEPTED RESCUE BOAT. 46CFR75.10-5(e)(1) and (2).
Condition: Unknown
Due 7 April 1995
Resolved 7 April 1995
Navigation
Issued 12 December 1994 Resolved
PROVIDE ONBOARD AN OPERATIONS MANUAL CONTAINING "PERIODIC SAFETY TEST PROCEDURE. 46CFR61.40-6.
Condition: Unknown
Due 7 April 1995
Resolved 7 April 1995

Casualty record · 39

26 January 2006Routine · role: Involved in a Marine Casualty · activity 2576130
29 January 2006Routine · role: Involved in a Marine Casualty · activity 2576602
8 September 2006Routine · role: Involved in a Marine Casualty · activity 2772791
16 September 2006Routine · role: Involved in a Marine Casualty · activity 2779785
27 April 2008Routine · role: Involved in a Marine Casualty · activity 3196541
23 October 2008Routine · role: Involved in a Marine Casualty · activity 3350562
15 January 2009Routine · role: Involved in a Marine Casualty · activity 3396749
14 February 2009Routine · role: Involved in a Marine Casualty · activity 3418761
28 February 2009Routine · role: Involved in a Marine Casualty · activity 3426255
7 March 2009Routine · role: Involved in a Marine Casualty · activity 3430096
22 March 2009Routine · role: Involved in a Marine Casualty · activity 3437848
27 March 2009Routine · role: Involved in a Marine Casualty · activity 3442580
14 July 2010Routine · role: Involved in a Marine Casualty · activity 3795406
15 March 2011Routine · role: Involved in a Marine Casualty · activity 3966750
19 March 2011Routine · role: Involved in a Marine Casualty · activity 3968384
21 May 2011Routine · role: Involved in a Marine Casualty · activity 4022676
19 August 2011Routine · role: Involved in a Marine Casualty · activity 4123630
12 September 2011Routine · role: Involved in a Marine Casualty · activity 4154623
13 June 2012Routine · role: Involved in a Marine Casualty · activity 4343923
18 October 2012Routine · role: Involved in a Marine Casualty · activity 4466885
2 January 2013Routine · role: Involved in a Marine Casualty · activity 4511877
18 February 2013Routine · role: Involved in a Marine Casualty · activity 4539647
10 April 2013Routine · role: Involved in a Marine Casualty · activity 4569061
8 June 2013Routine · role: Involved in a Marine Casualty · activity 4620975
9 September 2013Routine · role: Involved in a Marine Casualty · activity 4712066
24 July 2016Routine · role: Involved in a Marine Casualty · activity 5959884
3 June 2018Routine · role: Involved in a Marine Casualty · activity 6452190
30 September 2018Routine · role: Involved in a Marine Casualty · activity 6575361
21 October 2018Routine · role: Involved in a Marine Casualty · activity 6572049
14 July 2019Routine · role: Involved in a Marine Casualty · activity 6753227
28 November 2019Routine · role: Involved in a Marine Casualty · activity 6867406
23 February 2020Routine · role: Involved in a Marine Casualty · activity 6917396
26 February 2020Routine · role: Involved in a Marine Casualty · activity 6952604
13 July 2020Routine · role: Involved in a Marine Casualty · activity 7012092
17 July 2020Routine · role: Involved in a Marine Casualty · activity 7013963
12 July 2022Routine · role: Involved in a Marine Casualty · activity 7504855
19 July 2023Routine · role: Involved in a Marine Casualty · activity 7821539
30 October 2025Routine · role: Involved in a Marine Casualty · activity 8359350
22 February 2026Routine · role: Involved in a Marine Casualty · activity 8392616
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.