MAURY USCG vessel records Sign in
← All vessels

SULPHUR ENTERPRISE

SULPHUR ENTERPRISE is a 1994 tank ship. The Coast Guard has recorded 204 inspections since 1994, most recently in December 2025, along with 149 deficiencies, 12 operational controls and 26 casualty investigations between 2005 and 2025.

Records from 1994 to 2025. Most recent: inspection, 28 December 2025.

Built
1994
Last inspected
28 December 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9077044 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
409027
Flag
UNITED STATES
303520000
Maury page id
psix-409027

Inspections, by type

…with no type recorded65
Years with a record 31 calendar years (1994–2025)
The 204 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)491.5 ft × 90.0 ft × 47.5 ft
Registered tonnagegross 16,771 / net 5,031
ITC dimensions (L × B × D)491.5 ft × 90.0 ft × 47.5 ft
ITC tonnagegross 16,771 / net 5,031
BuilderMCDERMOTT SHIPYARD · AMELIA, LA, UNITED STATES · built 1994
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portTAMPA, FL
Trade endorsementsCoastwise, charter, Registry
DocumentationValid · issued 10 January 2026 · expires 28 February 2027
Service, as the file records itTank Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5031 - Convention (Subpart B), Net Ton
27375 - Dead Weight, Ton
16771 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

KAKBMMSI 303520000 · active · compulsorily equipped · granted 8 February 2018, expires 8 February 2028
KAKBMMSI 303520000 · terminated · compulsorily equipped · granted 20 February 2015, cancelled 8 February 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 5

Inspection history · 204

28 December 2025 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8287842
28 December 2025 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8290183
5 November 2025 Annual Inspection · ACP Annual Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8240985
24 September 2025 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 8240368
8 June 2025 Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8154743
23 April 2025 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8118120
22 April 2025 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8310375
11 February 2025 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8078371
11 February 2025 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8102417
27 January 2025 Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8070615
13 January 2025 ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8062797
13 July 2024 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7957438
28 June 2024 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7944281
21 April 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7899249
23 November 2023 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7828946
23 November 2023 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7838283
22 May 2023 ACP COI Oversight · Administrative Inspection · Re-Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7693932
26 March 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7657077
17 February 2023 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7638390
5 October 2022 Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7572453
29 April 2022 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7440659
28 April 2022 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7440159
26 October 2021 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7340312
15 October 2021 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7333418
15 October 2021 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7336578
5 October 2021 Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7313088
29 July 2021 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7271748
29 July 2021 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7277823
7 January 2021 MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7121234
9 October 2020 Administrative Inspection · ACP Annual Oversight · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7074566
9 October 2020 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7076264
26 May 2020 Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6961578
24 May 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6973293
18 May 2020 ACP Additional Oversight – Risk Assessment
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6956060
6 May 2020 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6949039
3 May 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6949080
3 May 2020 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6950444
12 February 2020 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6908040
23 October 2019 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6840619
21 October 2019 Annual Inspection · ACP Annual Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6838962
1 July 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6733277
11 June 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6719904
4 May 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6684975
25 April 2019 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6689686
9 April 2019 ACP Additional Oversight – Risk Assessment · Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6665981
4 April 2019 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6655631
28 March 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6651035
15 March 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6644416
8 March 2019 ISM Oversight · Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6674565
6 March 2019 Deficiency Check · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6637202
5 March 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6637334
5 March 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6637340
19 February 2019 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6631593
1 February 2019 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6618851
30 December 2018 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6604126
30 December 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6608067
15 December 2018 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6598451
15 December 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6601052
15 December 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6607957
3 December 2018 Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6591025
24 November 2018 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6585804
17 November 2018 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6583784
15 November 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6587039
12 November 2018 Administrative Inspection · ISM Oversight
Administrative · Commandant (CG-5P-TI) · Activity 6584249
7 November 2018 Examination of Repairs · ISM SMC Audit · ISM Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6577660
5 November 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6579066
24 October 2018 In-Service Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6567382
24 October 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6567557
16 October 2018 MTSA/ISPS Verification · Re-Inspection · ACP COI Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6542146
6 June 2018 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6435818
7 May 2018 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6409886
7 May 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6411981
16 February 2018 Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6356175
19 January 2018 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6340412
4 January 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6332577
19 December 2017 Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6326784
16 December 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6325852
21 November 2017 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6310972
16 November 2017 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6308309
25 October 2017 Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6294898
13 October 2017 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6287331
11 October 2017 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6285815
28 August 2017 Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6253669
13 July 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6208836
24 February 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6093947
19 September 2016 MTSA Verification · ACP Annual Oversight · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6004207
27 August 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6000427
15 August 2016 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5973682
26 February 2016 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5822447
23 January 2016 ISM Oversight
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5804287
30 December 2015 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5789800
29 December 2015 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5788587
8 December 2015 Administrative Inspection · ACP Periodic Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5781616
24 August 2015 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5226069
24 August 2015 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5781504
18 August 2015 In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5219738
17 October 2014 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5007199
3 October 2014 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4998605
18 August 2014 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4966291
23 June 2014 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4897667
6 March 2014 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4811599
19 January 2012 Damage Survey · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4227449
17 January 2012 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4229758
31 August 2011 MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4132588
18 August 2011 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4119567
2 November 2010 ACP Annual Oversight
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3882760
6 September 2010 Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3845351
5 September 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3843093
5 September 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3845804
26 February 2010 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3686603
8 December 2009 ACP Annual Oversight · Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3647276
11 July 2009 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3531698
29 April 2009 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3463918
13 February 2009 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3417446
26 September 2008 ACP COI Oversight · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3296533
8 August 2008 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3292858
17 June 2008 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3239770
22 February 2008 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3151588
10 January 2008 Ballast Water Examination · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3129514
3 January 2008 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3124453
1 November 2007 Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3091338
23 October 2007 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3085195
10 October 2007 Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3087182
27 July 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3009211
5 June 2007 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2952296
1 March 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2596960
1 December 2005 Type not recorded
No type recorded · Vessel Traffic Service Houston-Galveston · USCG Heartland District (CGD-H) · Activity 2562547
3 October 2005 ACP Annual Oversight · MTSA/ISPS Verification · Ballast Water Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2504132
8 July 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2419324
21 April 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2339626
26 February 2005 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2488044
1 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2284785
15 November 2004 ACP Annual Oversight
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2241506
27 October 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2229196
10 September 2004 Underwater Inspection in lieu of Drydock
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2192675
17 August 2004 Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2168992
16 August 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2167863
14 August 2004 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2198337
20 May 2004 MTSA/ISPS Verification
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2072906
6 January 2004 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1977132
17 November 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1950207
24 October 2003 ACP COI Oversight
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1935289
11 December 2002 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1717381
7 November 2002 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1490962
22 August 2002 Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1664880
21 December 2001 ACP COI Oversight
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1477843
10 November 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1630000
23 February 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 215911
2 October 2000 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1432383
3 August 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 221419
23 May 2000 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1049972
21 February 2000 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 815464
5 October 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 433373
5 October 1999 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 888735
26 February 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 222890
2 February 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 474467
4 October 1998 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1442761
12 August 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 141847
26 July 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 449005
24 June 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 96184
7 January 1998 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1120130
12 December 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 456567
16 October 1997 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1110499
15 October 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 96753
8 October 1997 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1394841
18 April 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 452415
12 December 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 398448
5 December 1996 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1091489
31 October 1996 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 856034
9 October 1996 Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1371585
20 September 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 508556
20 August 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1085704
28 May 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1084977
30 April 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 390739
30 April 1996 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1081288
20 March 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 495079
19 January 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1439683
27 December 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1184424
21 December 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 872346
28 November 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1191921
8 November 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1188333
29 September 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 383317
14 September 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1181005
8 September 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1363358
6 September 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 537791
20 August 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 151490
21 July 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1189599
11 July 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1398284
6 June 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 478453
22 May 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1181729
16 May 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1233025
27 April 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 863227
10 April 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1956
8 March 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 509032
14 February 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 842338
12 February 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 849199
4 January 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 857651
23 December 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422458
22 December 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 847621
19 November 1994 Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 866190
14 October 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 520706
7 October 1994 Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1179431
6 September 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 863020
31 August 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1459122

Deficiency record · 149

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 December 2025 Resolved
74SOLAS20 II-1 26.1 The machinery, boilers, and other pressure vessels, associates in piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board die to regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected to and the environmental conditions on board. Vessel reported a loss of propulsion during outbound transit. Vessel must enact permanent repairs to the satisfaction of ABS.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 December 2025
Resolved 29 December 2025
Resolution: Injection pump was replaced and engines tested to the satisfaction of ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 April 2025 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. MI received NRC notification stating vessel's crew discovered oil in the water around the vessel upon arrival to terminal. Oil was determined to originate from a propeller blade seal failure. Provide TPO finding number and technical report from ABS attesting to proper functioning propeller blade seal 74 SOLAS (04) II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2025
Resolved 27 April 2025
Resolution: Preliminary Report provided by ABS. Findning No. 1468.0. Attached in documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 February 2025 Resolved
The applicable standards established by the ABS Marine Vessel Rules may be used as the standard for the design, construction, and testing of main and auxiliary machinery. MI received notification from vessel representative stating vessel experienced loss of propulsion due to a failed sensor on the mechanical overspeed trip mechanism for the main engine. Provide TPO finding number and technical report from ABS attesting to proper operation of the vessel. 46CFR31.35-1 46CFR111.12-1 46CFR58.01-5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2025
Resolved 12 February 2025
Resolution: ABS Preliminary Report provided. Engineering crew replaced the proximity overspeed sensor. Operational test of the sensor was witnessed and considered satisfactory by attending ABS Surveryor.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 January 2025 Resolved
No repairs or alterations affecting the safety of the vessel or its machinery shall be made unless applicable requirements in this chapter are met. Vessel reported newly replaced booster relief valve(V1) failed. Notifications shall be conducted in accordance with the Alternate Compliance Program. Repairs shall be made to the satisfaction of the RO and Coast Guard. Coast Guard Marine Inspector attendance will be required prior to clearing deficiency. Repair report from tech/OEM and/or RO should discuss root cause and all corrective actions. No movement from the pier authorized unless authorized by the OCMI/COTP.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 February 2025
Resolution: CG MI attendance. See narrative and ABS report.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 January 2025 Resolved
74 SOLAS (97) II-2/15.2 In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. #1 fuel supply pump in purifier room was leaking fuel.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2025
Resolved 17 January 2025
Resolution: ABS accepted referral.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 17 January 2025 Resolved
MARPOL 73/78 1/14.2 Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation. OWS was not operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2025
Resolved 17 January 2025
Resolution: ABS accepted referral.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 17 January 2025 Resolved
74 SOLAS (04) II-1/44.2 A second source of energy shall be provided for an additional three starts within 30 minutes. Emergency generator would not start using second source.
Action required: 10 - Deficiency Rectified
Due 17 January 2025
Resolved 17 January 2025
Resolution: Seconnd source of energy was not set at correct pressure. EDG started three time once pressure was set correctly.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 July 2024 Resolved
The main steering gear and rudder stock must be operated by power when necessary to comply with paragraph (b)(2) of this section. Vessel suffered loss of steering capabilities on the starboard steering gear pump. Prove proper operation of power steering prior to departure from the Gulf Sulphur Services dock in Tampa, FL to the satisfaction of attending ABS class surveyor. 46 CFR 58.25-10(b)(3)
Action required: 17 - Rectify deficiencies prior to departure
Due 13 July 2024
Resolved 16 July 2024
Resolution: Received preliminary survey report from ABS, attesting to satisfactory operation of steering equipment and vessel procedures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 April 2024 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. CPP system controls do not operate in "follow up" mode as designed. Repair to the satisfaction of the vessel's classification society and the Coast Guard. 74SOLAS(04)II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2024
Resolved 29 April 2024
Resolution: Repairs completed SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 November 2023 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Vessel stern tube is leaking oil through the seal and into the ocean. Repair to the satisfaction of the vessel's classification society and the Coast Guard. 74 SOLAS (04) II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 November 2023
Resolution: Received class preliminary report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2023 Resolved
Except as provided in paragraph (d) of this section, this subpart applies to each self-propelled vessel that- (1) Carries oil of any kind as fuel for main propulsion; (2) Is not a tank vessel or is not certificated as a tank vessel; (3) Operates upon the navigable waters of the United States, as defined in 46 U.S.C. 2101(17a); and (4) Is 400 gross tons or more as measured under the convention measurement system in 46 U.S.C. 14302 or the regulatory measurement system of 46 U.S.C. 14502 for vessels not measured under 46 U.S.C. 14302. Vessel must activate NTVRP and notify OSRO prior to transiting. 33 CFR 155.5015
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 November 2023
Resolution: Vessel notified QI.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 5 October 2022 Resolved
A liferaft for use with an approved launching appliance shall: be provided with means for bringing the liferaft alongside the embarkation deck and holding it securely during embarkation. Marine Inspectors observed that the starboard side davit-launched liferaft cannot be brought alongside the embarkation deck due to its location relative to the installed davit, which was installed to replace an existing davit on September 2021. Additionally, the davit-launched liferaft exceeds the newly installed davit's service workload and therefore requires an approved launching appliance. This deficiency is to be rectified to the satisfaction of the vessel's Recognized Organization. 74SOLAS(97)III/38.4.1.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2022
Resolved 31 October 2022
Resolution: RO (ABS) providing oversight of complete rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 5 October 2022 Resolved
In lieu of meeting the requirements of paragraph 1.1, cargo ships may carry: (In addition to one or more lifeboats) one or more liferafts complying with the requirements of regulation 39 or 40, on each side of the ship, of such aggregate capacity as will accommodate the total number of persons on board. Marine Inspectors observed life rafts with a capacity of 25 persons, which is less than the 27 total personsallowed onboard per the Certificate of Inspection (COI). Therefore, the vessel is allowed to carry no more than 25 persons onboard. The COI will be amended to reflect this change. 74SOLAS(97)III/26.1.2.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 5 October 2022
14 - Pollution Prevention › 148 - Ballast Water › Ballast water discharge
Issued 28 April 2022 Resolved
Unless otherwise expressly provided...the master, owner, operator, agent, or person in charge of vessels employing a CG approved BWMS must meet the applicable ballast water discharge standard, found in 151.2030 of this subpart, at all times of discharge into the waters of the US. Master of vessel reported discharging of untreated ballast from aft peak tank, which is not IAW with vessels BWMP. Vessel is prohibited BW discharge of AP tank in US waters, and master must submit contingency plan to verify how the vessel is intending to comply with the BWM requirement to the satisfaction of the local COTP.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2022
Resolved 4 May 2022
Resolution: ABS accepted def and issued finding # 1396.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 October 2021 Resolved
THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. #2 GENERATOR WAS REPORTED INOPERABLE. 74SOLAS(04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2021
Resolved 19 October 2021
Resolution: Deficiency rectfied on receipt of ABS Preliminary Report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 5 October 2021 Resolved
Administrations shall require that records of daily hours of rest of seafarers be maintained in a standardized format, in the working language or languages of the ship and English, to allow monitoring and verification of compliance with the provisions of this section. The seafarers shall receive a copy of the records pertaining to them which shall be endorsed by the master or by a person authorized by the master and by the seafarers. Identified engineer officers logged import hours while vessel was in transit. Underway watch hours were corrected onscene.
Action required: 10 - Deficiency Rectified
Due 5 October 2021
Resolved 5 October 2021
Resolution: Crew corrected the hours that were improperly listed - all sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 5 October 2021 Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the ORB I so that all entries in the book appropriate to that operation are completed. Entries in Oil Record Book for sludge tank to tank transfers were entered incorrectly under code (C) 12.1. Tank to tank transfers should be entered under (C) 12.2.
Action required: 10 - Deficiency Rectified
Due 5 October 2021
Resolved 5 October 2021
Resolution: Crew made addtional entry into Oil Record Book correcting the improper entries made - all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 October 2021 Resolved
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency, for a period of 18h emergency lighting: accomodation alleyways, stairway and exits. Identified 2 interior lights 01 deck & 1 exterior light on the 02 deck that are extinguished.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2021
Resolved 8 October 2021
Resolution: Recieved finding # for the above deficiency. After ABS clears def will upload document into documents section. 11/1/2021 ABS provided documentation clearing def.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 October 2020 Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles. Deck plating in engine room around emergency escape are missing, rendering the emergency escape inaccessible. 74SOLAS(14) II-2/13.1.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2020
Resolved 15 October 2020
Resolution: Received ABS survey report stating deck plating has been replaced and verfied to meet ABS standards. Received pictures from operator verfying replacement.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 October 2020 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual and periodic inspections within the periods specified in 31.10-17 (a) and (b) and your Certificate of Inspection must be endorsed. Vessel's anniversary date is July 10th. The annual inspection was due by 10OCT2020 to maintain a valid Certificate of Inspection. Prior to conducting cargo operations complete an annual inspection. 46 CFR 31.10-17a
Action required: 705 - Other - as specified
Due 10 October 2020
Resolved 14 October 2020
Resolution: Completed Annual Inspection as required.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 25 April 2019 Resolved
Any ship of 10,000 Gt and above shall be fitted with oil filtering equipment complying with par. 7 of this reg. After reviewing the ORB and speaking with the C/E it was discovered that the OWS has been inpoperable since March 15, 2019. Class (ABS) issued the IOPP but had rcvd no notification of the OWS being inoperable prior to this inspection. Make permanent repairs of the OWS and prove proper working condition.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2019
Resolved 29 April 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 April 2019 Resolved
The main inlets and outlets of all ventilation systems shall be capable of closing from outside the spaces being ventilated. Bow thruster room ventilation closure inoperable in the open position. Make permanenet repairs and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2019
Resolved 29 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 April 2019 Resolved
Fire doors in main vertical zone bulkheads shall be self closing and be capable of self closing with an angle of inclination of up to 35 degrees. Cargo control room door not fully closing when released. Adjust door and prove proper closure. SOLAS CH. II-2 Reg. 9.4.1.1.4.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 25 April 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 April 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Port main deck weather tight door showed day light through gasket when closed. Make neccessary adjusts to ensure weather tight integrity of the door.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 25 April 2019
08 - Alarms › N/A - No Subsystem › General alarm
Issued 25 April 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Upon activation of the general alarm system it was observed that in the pump room the general alarm only produced a visual alarm and no audible. Repair or replace alarm and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 29 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 25 April 2019 Resolved
Maintenance, testing and inspections of life saving appliances shall be carried out based on the guidelines of the organization and in a manner having due regard to ensuring reliability of such appliances. During inspection it was observed that the retro tape on the rescue boat was severly worn and in poor condition, also the fwd painter line for the rescue boat was sun damaged and frayed and in extremely poor condition. Replace as neccessary.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 29 April 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 9 November 2018 Resolved
After 1 July 2002 all vessels shall comply with the International Safety Management (ISM) Code as amended. Preliminary assessment of the vessel’s Safety Management System (SMS). Interviews with the Master, Chief Engineer, Port Engineer [name withheld] (DPA), along with review of previous internal and external audits provide objective evidence that a SMS has not been fully implemented. Essential elements of the code have not been fully addressed or implemented, additionally non-conformity corrective actions required by the Recognized Organization (RO) in external audits conducted on 28 Dec 2017 and 10 Apr 2018 have not been completed. An external audit, attended by the Coast Guard, is required prior to release from detention.
Action required: 30 - Ship detained
Due 23 November 2018
Resolved 14 November 2018
Resolution: Deficiency cleared
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 9 November 2018 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements, which may be established by the company. Clear grounds as a result of the vessel having suffered multiple equipment failures, onboard fires & propulsion losses identified in either the below deficiencies or previous vessel history led to an expanded ISM exam revealing the vessel/company did not document and report non-conformities in accordance with the requirements of the ISM Code, and failed to follow procedures for implementing corrective action.
Action required: 30 - Ship detained
Due 23 November 2018
Resolved 14 November 2018
Resolution: Def cleared
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 9 November 2018 Resolved
The Company should identify equipment and technical systems the sudden operational failure of which may result in hazardous situations. The SMS should provide for specific measures aimed at promoting the reliability of such equipment or system. These measures should include the regular testing of stand-by arrangements and equipment or technical systems that are not in continuous use. The master and DPA stated there was not a list of equipment or technical systems identified as required by the Code. This non-conformity was previously identified by the RO in external audits conducted 28 Dec 2017 and 25 Jan 2018.
Action required: 30 - Ship detained
Due 23 November 2018
Resolved 14 November 2018
Resolution: def cleared
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 9 November 2018 Resolved
The Company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. The various tasks should be defined and assigned to qualified personnel. Shipboard and company personnel stated that since the requirements of ISM Code, Part A, Clause 10.3 had not been complied with, procedures to address those technical systems and equipment have not yet been established.
Action required: 30 - Ship detained
Due 23 November 2018
Resolved 14 November 2018
Resolution: def cleared
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 9 November 2018 Resolved
Companies should include procedures ensuring non-conformities, accidents and hazardous situations are reported to the Company, investigated and analyzed with the objective of improving safety and pollution prevention. Since issuance of the vessel’s SMC in Jan 2018 and despite multiple equipment failures, an onboard fire and casualties only two “Event Reports” have been submitted by the vessel. One personnel casualty dated 24 Oct 2018 and one non-conformity dated 28 Oct 2018.
Action required: 30 - Ship detained
Due 23 November 2018
Resolved 14 November 2018
Resolution: def cleared
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 9 November 2018 Resolved
Personnel carrying out audits should be independent of the areas being audited. The internal audit conducted on the vessel 15-16 Sep 2017 and internal audits conducted on two other company vessels were independently completed by the DPA. These audits included “Findings” that should have been identified as non-conformities, for example; “FMS has not fully been integrated”, “SMS required Crewmember sign-on sheet (MPM Form 3.01) was fond missing from the SMS documentation and not in use” and “SCBAs were reported as not operational, no records of inspection could be found. It was reported by the crew that SCBAs had not worked properly for months."
Action required: 30 - Ship detained
Due 23 November 2018
Resolved 14 November 2018
Resolution: Def cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 November 2018 Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least two generating sets. Vessel Captain reported generator #3 is down for repair, generator #2 intermittently fails to hold the electrical load, and generator #1 is operational but is emitting excessive white smoke. Make permanent repairs and prove proper operation and reliability to the satisfaction of the attending ACP ACS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2018
Resolved 13 November 2018
Resolution: Deficiency was accepted by class and rectified
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 9 November 2018 Resolved
The electrical power available shall be sufficient to supply all those services that are essential for the safety in an emergency, due regard being paid to such services as may have to be operated simultaneously. Vessel Captain reported the emergency generator has failed to pick up the emergency load during vessel blackouts. Make permanent repairs and prove proper operation and reliability to the satisfaction of the attending ACP ACS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2018
Resolved 13 November 2018
Resolution: Deficiency was accepted and rectified by class
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 November 2018 Resolved
The main steering gear shall be so arranged that in the event of loss of steering capability due to a single failure in any part of one of the power actuating systems of the main steering gear, excluding the tiller, quadrant or components service the same purpose, or seizure of the rudder actuators, steering capability shall be regained in not more than 45 s after the loss of one power actuating system. Vessel Captain reported the vessel is experiencing issues with the automatic switching between steering pumps. Make permanent repairs and prove proper operation and reliability to the satisfaction of the attending ACP ACS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2018
Resolved 13 November 2018
Resolution: Deficiency was accepted and rectified by class
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 24 October 2018 Resolved
The vessel's main storage fuel tank, settling tank and day tank have been contaminated with bad fuel causing fuel system to clog and prevent MDE and SSDGs to run properly. Remove contaminated fuel, clean all tanks and restore fuel supply system to satisfactory condition. Provide class report attesting to the proper operation of the fuel supply system.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2018
Resolved 28 October 2018
Resolution: All vsl diesel fuel tanks have been emptied, cleaned and refilled. MI witnessed a two hour operational test of the MDE's and SSDG's fuel supply system, to include separators, buster&service pumps. All systems ran within sat parameters. Class rpt attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 October 2018 Resolved
The vessel has a new/updated Automation system installed. PSTPs need to be updated and approved to reflect new system. Also, until ABS issues final approval and the OCMI witnesses proper operation of the system, PUMS is not authorized.
Action required: 705 - Other - as specified
Resolved 12 February 2020
Resolution: Vessel does not wish to pursue PUMS and PUMS endorsement has been removed from COI.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 16 October 2018 Resolved
Vessel's SMS requires the use of a Fleet Management Software (FMS)(i.e NSE). Vessel is currently using excel spreadsheets as thier preventitive maintenance system which is contrary to the RO approved SMS.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 March 2019
Resolution: Vessel has fully implemented their FMS (NSE). Recieved from ABS a full term SMC and audit report.
Construction/Loadline › Structures › Door
Issued 8 January 2018 Resolved
The knife edge leading into the CO2 room is wasted and no longer capable of maintaining a weather tight seal. Make repairs to the satisfaction of the attending ACP ACS. (reissued from Act # 6326784)
Action required: 705 - Other - as specified
Resolved 28 March 2018
Resolution: Knife edge repaired SAT.
Documentation › Logs/Records › Oil Record Book
Issued 8 January 2018 Resolved
Every ship of 400 GT and above other than an oil tanker shall be provided with an Oil Record Book (ORB) Part 1 (Machinery space operations). The ORB shall be in the form specified in appendix III of MARPOL Annex I. The vessel is maintaining ORB CG-4602A (Rev.01-07). Rev 11-16 is the current version of ORB CG-4602A, which complies with MARPOL. Provide correct version of ORB to the satisfaction of the attending ACP ACS. (reissued from Act # 6326784)
Due 20 January 2018
Resolved 22 March 2018
Resolution: Provided ship with revised ORBs.
Communications › Public Address System › Loudspeaker
Issued 8 January 2018 Resolved
The general emergency alarm system shall be supplemented by either a public address system or other suitable means of communication capable of broadcasting messages into all spaces where crew members are normally present. the installed system is not fully functional. Make repairs and demonstrate functionality to the satisfaction of the attending ACP ACS. (reissued from Act # 6326784)
Action required: 705 - Other - as specified
Due 20 January 2018
Resolved 2 July 2019
Resolution: Rcv'd and accepted Class Report. cleared. Def # 1286 from ABS report.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 4 January 2018 Resolved
Master, chief engineers, chief mates, and second (1st A/E) engineers on chemical tankers shall hold a certificate in advanced training for chemical tanker cargo operations. The chief engineer's MMC is not endorsed as required. Provide onboard as required in compliance with the minimum safe manning document to the satisfaction of the USCG.(reissued from Act # 6326784)
Action required: 10 - Deficiency Rectified
Due 20 January 2018
Resolved 26 April 2018
Resolution: All crew's licenses and endorsements SAT.
Lifesaving › Lifeboat › Propeller
Issued 20 December 2017 Resolved
Before ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. Upon examination, the freefall lifeboat rudder found cracked through at the lower post and in three locations on the rudder skeg. make temp repairs to the satisfaction of the USCG or ACP ACS prior to departure from port.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 December 2017
Resolution: Satisfied attending USCG inspector
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 20 December 2017 Resolved
After Jan 1, 2017 all persons employed or engaged on board vessels to which STCW applies must hold a medical certificate valid for 2 years. Three crew members (AB, DEU, Steward) found on board with expired medical certificates. Provide on board prior to sailing in compliance with the minimum safe manning document to the satisfaction fot the USCG.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 December 2017
Resolution: Vessel met safe manning requirements by providing alternate crew members with applicable certificates.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 20 December 2017 Resolved
On board a seagoing vessel, no person may assign a shipboard duty or responsibility to any person who is assigned a responsibility on the muster list unless the person can produce evidence of having recieved appropriate approved STCW basic training. One crew member (DEU) found on board could not produce evidence of completing approved STCW basic training. Provide on board prior to sailing in compliance with the minimum safe manning document to the satisfaction fot the USCG.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 January 2018
Resolution: Training certificate was produced.
Deck/Cargo › Cargo Stowage › General
Issued 20 December 2017 Resolved
The Detcon Model 10 fixed gas detection system is not functioning as designed and not capable of detecting H2S. Make repairs and prove proper operation to the satisfaction of the attending ACP ACS. IBC Code Ch. 17
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 December 2017
Resolution: Provided satisfactory class report and technician's report attesting to the replacement of malfunctioning fixed gas detection system sensors and functionality of the system.
Construction/Loadline › Structures › Door
Issued 20 December 2017 Resolved
The knife edge leading into the CO2 room is wasted and no longer capable of maintaining a weathertight seal. Make repairs to the satisfaction of the attending ACP ACS.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 January 2018
Resolution: Corrected to USCG satisfaction.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 20 December 2017 Resolved
Any STCW Certificate must be kept available in its original form on board the ship on which the holder is serving. The original certificates for one AB/RFPNW were not available on board, copies were presented for inspection. Provide original certificates (MMC/TWIC/Medical Certificate) on board as required in compliance with the minimum safe manning to the satisfaction of the USCG. STCW Reg. I/2.11
Condition: Improper/Lack of Maintenance
Due 27 December 2017
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 20 December 2017 Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with the effective means for its operation and control. The RPM gauges for the #2 and 3 SSDGs were not operable and the #1 could not be verified. Make repairs and prove operation to the satisfaction of the attending ACP ACS. 74 SOLAS (1997 Cons.) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 January 2018
Resolved 8 January 2018
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 20 December 2017 Resolved
The machinery shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to hot surfaces and other hazards. Evidence of an exhaust leak noted from the main engine air box. Make repairs to the satisfaction of the attending ACP ACS. 74 SOLAS (1997 Cons.) II-1/26.1
Condition: Improper/Lack of Maintenance
Due 3 January 2108
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Engineering › Sea-water System (primary cooling) › Pump
Issued 20 December 2017 Resolved
The machinery shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts. Safety guards for moving parts associated with the raw water cooling pumps and EDG missing. Install to the satisfaction of the attending ACP ACS. 74 SOLAS (1997 Cons.) II-1/31.1
Condition: Improper/Lack of Maintenance
Due 3 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 20 December 2017 Resolved
Masters, chief engineers, chief mates, and second (1st A/E) engineers on chemical tankers shall hold a certificate in advanced training for chemical tanker cargo operations. The chief engineer's MMC is not endorsed as required. Provide on board as required in compliance with the minimum safe manning document to the satisfaction of the USCG. STCW Reg. V/1-1.5
Due 20 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 December 2017 Resolved
Upon application for any Certificate of Documentation (COD), the owner of a vessel must designate a hailing port to be marked upon the vessel. The current COD, issued 20 July 2017, reflects a hailing port of Tampa, FL. The stern has been marked Mobile, AL. The stern is to be marked to confirm with the hailing port in accordance with 46 CFR 67.123 to the satisfaction of the USCG. 46 CFR 67.119
Condition: Improper/Lack of Maintenance
Due 3 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Documentation › Certificates/Documents › International Certificate of Fitness (IBC Code)
Issued 20 December 2017 Resolved
International certificates shall be drawn up in a form corresponding to the model given in the respective Convention. Convention certificates reflect the Port of Registry as Mobile, AL. Vessels registration has been updated for Tampa, FL. Provide revised Convention certificates on board to the satisfaction of the USCG. 74 SOLAS (2014 Cons.) I/15 All Ships MARPOL I/9; VI/8; LLC, IAFSC, etc.
Condition: Invalid
Due 3 January 2018
Resolved 11 January 2018
Resolution: Signed [name withheld] provided by ABS.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 20 December 2017 Resolved
Every ship to which chapter I applies shall be issued with a Continuous Synopsis Record (CSR) which shall contain the identification of the Company (as defined in regulation IX/1) the ISM SMC and DOC list the Company ID number as 5951433, whereas the CSR lists 5951671. Revise and provide on board to the satisfaction of the USCG 74 SOLAS (2014 Cons.) XI-1/5
Condition: Improper/Lack of Maintenance
Due 3 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Documentation › Logs/Records › Oil Record Book
Issued 20 December 2017 Resolved
Every ship of 400 GT and above other than an oil tanker shall be provided with an Oil Record Book (ORB) Part 1 (Machinery space operations). The ORB shall be in the form specified in appendix III of MARPOL Annex I. The vessel is maintaining ORB CG-4602A (Rev.01-07). Rev 11-16 is the current version of ORB CG-4602A, which complies with MARPOL. Provide correct version of ORB to the satisfaction of the attending ACP ACS. MARPOL Annex I/17.1
Condition: Invalid
Due 20 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Communications › Public Address System › Loudspeaker
Issued 20 December 2017 Resolved
The general emergency alarm system shall be supplemented by either a public address system or other suitable means of communication capable of broadcasting messages into all spaces where crew members are normally present. The installed system is not fully functional. Make repairs and demonstrate functionality to the satisfaction of the attending ACS ACS. 74 SOLAS (1997 Cons.) III/4.2
Condition: Improper/Lack of Maintenance
Due 20 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 20 December 2017 Resolved
The 11 April 1995 Stability Letter, cited by the Intl. Load Line Certificate (ILLC), references the ABS approved "Sulphur Enterprise Loading Manual" dated 16 March 1995. This manual could not be located on board. Provide on board or update Stability Letter and ILLC to the satisfaction of the attending ACP ACS. ILL 66 Art. 16
Condition: Improper/Lack of Maintenance
Due 20 January 2018
Resolved 27 March 2018
Resolution: Deficiency rectified as stated on SAFENET: Full Rectification: It was verified the vessel has marked the life-saving equipment storage with symbols in accordance with Resolution A.760(18).
Lifesaving › Lifebuoys › Stowage
Issued 20 December 2017 Resolved
Containers, brackets, racks, and other similar stowage locations for life-saving equipment shall be marked with symbols in accordance with Resolution A.760(18), as amended, indicating the devices stowed in that location for that purpose. If more than one device is stowed in a location, the number of devices shall also be indicated. Mark the stowage locations for life-saving equipment as required to the satisfaction of the attending ACP ACS. 74 SOLAS (2014 Cons.) III/20/10 All Ships
Condition: Improper/Lack of Maintenance
Due 30 January 2018
Resolved 27 March 2018
Resolution: Full Rectification It was verified the vessel has marked the life-saving equipment storage with symbols in accordance with Resolution A.760(18).
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 December 2017 Resolved
Each lifebuoy shall be marked in block capitals with the port of registry of the ship on which it is carried. Mark all life-saving equipment required to be marked with the port of registry to the satisfaction of the attending ACP ACS. 74 SOLAS (1997 Cons.) II/7.1.4
Condition: Improper/Lack of Maintenance
Due 3 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 20 December 2017 Resolved
The lifeboat's stbd. side aft water spray fixture was found inoperable. Make repairs and prove operation of all water spray fixturs to the satisfaction of the attending ACP ACS. 74 SOLAS (2014 Cons.) III/20.2 All ships
Condition: Improper/Lack of Maintenance
Due 3 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 20 December 2017 Resolved
The port side hydraulic ram and associated control piping for the lifeboat davit found with evidence of hydraulic leakages. Make repairs and prove operation to the satisfaction of the attending ACP ACS. 74 SOLAS (2014 Cons.) III.20.2 All ships
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 January 2018
Resolved 25 April 2018
Resolution: Hydraulic rams operational test SAT. No apparant leak.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 20 December 2017 Resolved
Make permanent repairs to the lifeboat rudder, skeg and bearing in accordance with the manufacturer, to the satisfaction of the attending ACP ACS. 74 SOLAS (2014 Cons.) III 20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 February 2018
Resolved 24 April 2018
Resolution: Satisfactory repairs made to vessel's skeg, rudder and bearing.
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 20 December 2017 Resolved
Stbd. side aft mooring chaulk found cracked. Make repairs to the satisfaction of the attending ACP ACS. Repair scheduled to be conducted at drydock. 74 SOLAS (2014. Cons.) I/11
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 March 2018
Resolved 25 April 2018
Resolution: Chaulk replaced in kind. All SAT.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 20 December 2017 Resolved
The Class A boundary between the emergency generator space and the CO2 room found hole and temporarily repairs with epoxy and a doubler. Make permanent repairs to restore integrity of the boundary to the satisfaction of the attending ACP ACS. Repair schedualed to be done at drydock. 74 SOLAS (2014 Cons.) II-2/44.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 March 2018
Resolved 24 April 2018
Resolution: Repaired with insert; SAT. Tested SAT.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 20 December 2017 Resolved
The company should ensure that each ship is manned with qualified, certificated and medically-fit seafarers in accordance with national and international requirements. Section 1.01 of the Savage Marine Management Company Vessel Procedures Manual (VPM)specifies the administrative procedure for crewmember sign-on, including the completion of form VPM F-1.01 (Crew Credentials Checklist). On board verification of crew credentials found the following: - 03 had expired medical certificates prior to signing-on - 01 did not have STCW basic training - 01 did not have endorsement for the required advanced training for chemical tanker cargo operations; - 01 did not have original certificates on board No records of form VPM F-1.01 were available for review on board. Following investigation and analysis, Company to provide documentation of corrective action attesting to the implementation of Section 1.01 of the company VPM. The Recognized Organization (ABS) is to attest to the verification of corrective action and conformance to ISM Code A/6.2 74 SOLAS (2014 Cons.) IX/3.1 All Ships // ISM Code Part A/6.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 January 2018
Resolved 26 April 2018
Resolution: Crew's licenses and endorsements SAT.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 16 December 2017 Resolved
Repair/replace low sea chest remote reach rod system. Machinery space to remain manned in accordance with minimally attended machinery space standards with live wach at all times until ACCU notation is restored by the vessel's ACS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Engineering › Steering Gear System › Pump
Issued 16 November 2017 Resolved
Port steering gear is experencing intermittent alarms causing changeover to stbd steering pump.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 November 2017
Resolution: Revieved satisfactory class report form ABS attesting to the porper opertaion of the port steering gear.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 11 October 2017 Resolved
Provide short term SMS addendum for H2S training and monitoring procedures prior to arrival in Galveston TX. Submit procedures to [name withheld] and MSU Texas City for approval. Cargo operations may not commence until approval.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2017
Resolved 13 October 2017
Resolution: Reviewed risk assessment and contingency plan in regards to inoperable H2S sensor. All submitted documentation found satisfactory.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 20 September 2016 Resolved
Voyage Data Recorder was found and reported to be inoperable. Vessel is restricted to domestic voyages only. SOLAS CH V Reg. 20
Action required: 705 - Other - as specified
Due 27 September 2016
Resolved 28 September 2016
Resolution: Power Distribution Unit replaced.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 23 January 2016 Resolved
Provide liferaft capable of being launched by davit and all necessary arrangements. IAW SOLAS 97 Reg. III / 26.1.2.2
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 February 2016
Resolved 25 February 2016
Resolution: USCG approved davit launch life raft installed with associated launching equipment.
Personnel › Certificates/Documents/Licenses › License, First Assistant Engineer
Issued 23 January 2016 Resolved
Provide onboard first assistant engineer with tankerman endorsement. IAW 46 CFR 15.860(f)(2)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2016
Resolution: Received report from Captain attesting to new First Assistant hire, arrived on board, license checked to verify proper endorsement. All sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 29 December 2015 Resolved
Exhaust gases have been detected in the main engines jacket cooling water system.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 29 December 2015
Resolved 31 December 2015
Resolution: Repairs made to the satisfaction of ABS and USCG Duty [name withheld] narrative 5789800
Documentation › Logs/Records › Oil Record Book
Issued 8 December 2015 Resolved
Oil Record book entries were not made for the collection of Leaking fuel from generator flat that was poured into the sludge tank. Additionnaly ORB entries were not made reflecting OWS being taken out of service. 33CFR151.25
Action required: 705 - Other - as specified
Due 8 December 2015
Resolved 8 December 2015
Resolution: Vessel master and Chief Engineer were trained on the proper way to maintaine a ORB. Corrected on the spot.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 8 December 2015 Resolved
The Fire Control plan in the area of the Generator Flat and the Purifer room in incorrect. Make corrections to door locations and bulkhead boundries to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2016
Resolved 8 February 2016
Resolution: Corrected to the satisfaction of Class.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 8 December 2015 Resolved
The Automation Test Procedures(ATP's) developed in support of the periodcically unattended machinery space (PUMS) are outdated. Update the ATP's to reflect current conditions and equipment. Submit updated ATP's and schedule full test of ATP's with cognizant OCMI for approval.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 17 August 2016
Resolution: ATP reviewed, approved and procedures stamped.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 8 December 2015 Resolved
The sewage pump discharge piping is temporarly repaired with soft patches. The MSD inlet pipe is also temporarly repaired with a soft patch. Make a repair proposal to local OCMI by 08Jan2016. Update: Repair proposal/extension req received; new due date of 17Feb2016 given.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 February 2016
Resolved 11 February 2016
Resolution: Received and accepted class report (T3080899)listing holed inlet and discharge sewage piping has been renewed. Approximately 9-feet of 3-inch schedule 80 seamless steel pipe, tested for tightness, found no apparent leaks.
Engineering › Fuel Oil Service System › Piping
Issued 8 December 2015 Resolved
All 3 SSDG's have their fuel leak detection alarms bye-passed by allowing fuel to leak directly past the alarm's activation float switch and into a 5 gallon bucket. Make repairs to the SSDG's fuel system and provide tech report attesting to the proper operation of the system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 December 2015
Resolved 9 December 2015
Resolution: Vessel had Wartzilla mech replace multiple fuel injectors, lines, and fuel pumps. Class attended and attested to the repairs.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 24 August 2015 Resolved
Fractured component on the supply side pulse dampner on the main diesel engine fuel manifold.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2015
Resolution: Fuel supply dampner was removed and sent ashore for permanent repairs and reinstalled. Repairs done by certified welders using approved procedures. After completiion, all repairs were nondestructively examined and found to be satisfactory.
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 March 2014 Resolved
S-Band radar inoperable. Repair radar and verify operation in the presence of a Marine Inspector, IAW 33 CFR 164.37.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 March 2014
Resolution: Loose wire in magnetron was resoldered, radar is now functional.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 8 December 2009 Resolved
Self closing fire door, STBD galley, found missing. Install approved door in accordance with structural fire protection requirements. Update fire control plan.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 January 2010
Resolved 12 January 2010
Resolution: ABS Surveyors report verified item was completed satisfactorily.
Lifesaving › Inflatable Liferafts › Float Free
Issued 8 December 2009 Resolved
Two life rafts stowed beneath gangway storage. Relocate life rafts or gangway stowage arrangement to ensure float free arrangement. Update fire control plan. Until item 2 (this item) complete, relocate brow. A crane is used to lift brow from STBD quarter main deck to aft 02 structure, the brow stows above the life rafts blocking float free arrangement.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 January 2010
Resolved 12 January 2010
Resolution: ABS Surveyors report verified item was completed satisfactorily.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 8 December 2009 Resolved
CO2 diffusers blocked by I-beam in purifier room. Relocate I-beam or provide approved modification arrangement for fixed fire control system.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 January 2010
Resolved 12 January 2010
Resolution: ABS Surveyors report verified item was completed satisfactorily.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 8 December 2009 Resolved
Port Galley door tied open, unable to self close. Ensure all galley doors are capable of self closing. When untied, the door close mechanism has no spring tension to self close, door swings freely.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 January 2010
Resolved 12 January 2010
Resolution: ABS Surveyors report verified item was completed satisfactorily.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 8 December 2009 Resolved
Certificate of Documentation was found expired 30 NOV 2009. Company failed to renew the vessel's COD. An examination of the bridge log proved that vessel had operated for 7 days without a valid COD. Vessel provided a copy of a valid Certificate of Documentation before being allowed to sail again.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 December 2009
Resolved 8 December 2009
Resolution: National Documentation center contacted and new Certificate of documentation provided by ships company office.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 8 December 2009 Resolved
Rubber matting in front of main SWBD and group 3 starter panel in poor condition and of inadequate length. Replace with proper rubber matting.
Action required: 705 - Other - as specified
Due 7 January 2010
Resolved 12 January 2010
Resolution: ABS Surveyors report verified item was completed satisfactorily.
Engineering › Shafting/Propeller Arrangements › Intermediate Shaft
Issued 11 July 2009 Resolved
Rear main seal worn causing oil leak.
Action required: 705 - Other - as specified
Due 25 July 2009
Resolved 17 July 2009
Resolution: ABS cleared vessel
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 11 July 2009 Resolved
Two pipes on top had rotted out and had some type of puddy keeping them from leaking. A couple more pipes on top were getting ready to break off and start leaking. Aft tank plating had a bad spot about 8 square inches that was almost rotted all the way through.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2009
Resolved 14 July 2009
Resolution: ABS cleared vessel
Fire Fighting › Structural - B Class Divisions › Doors
Issued 26 September 2008 Resolved
Repair closures and latches on boundary doors to 01 Deck stairwell and officers laundry.
Action required: 705 - Other - as specified
Due 3 October 2008
Resolved 2 October 2008
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 January 2008 Resolved
Replace or repair automatic closure on on garbage room fire door.
Condition: Improper/Lack of Maintenance
Due 20 January 2008
Resolved 29 February 2008
Fire Fighting › Ventilation Systems › Fans
Issued 10 January 2008 Resolved
Provide proper exhaust fan for purifier room.
Condition: Damaged By Earlier Event
Due 20 January 2008
Resolved 29 February 2008
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 10 January 2008 Resolved
Provide exhaust duct and lint trap for laundary dryer located in the engine room.
Condition: Improper Installation
Due 20 January 2008
Resolved 29 February 2008
Fire Fighting › Ventilation Systems › Ducts
Issued 10 January 2008 Resolved
Repair or renew deteriorated ventillation duct plenum IWO starboard engine room main duct forward branch.
Condition: Improper/Lack of Maintenance
Due 10 February 2008
Resolved 29 February 2008
Engineering › Steering Gear System › Rudder
Issued 10 January 2008 Resolved
Provide ABS approved repair proposal for fractures IWO rudder horn where brackets attach to the horn.
Condition: Design Flaw
Due 10 February 2008
Resolved 29 February 2008
Deck/Cargo › Cargo Heating › General
Issued 1 November 2007 Resolved
Renew metallic flex hose on thermal fluid heating system on fwd manifold. Test system once replaced to normal working pressure ensuring all leaks are secured.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 December 2007
Resolved 5 November 2007
Resolution: Hose was replaced and system was tested sat.
Deck/Cargo › Cargo Heating › General
Issued 1 November 2007 Resolved
Provide specifications on replacement parts and ABS report that confirms new fittings are acceptable for system on the vsl.
Action required: 705 - Other - as specified
Due 1 December 2007
Resolved 5 November 2007
Resolution: Received letter from ABS that confirms new fittings for system.
Navigation › Collision/Grounding Avoidance › Radar
Issued 16 August 2004 Resolved
Received fax from LMS Shimpmanagement, Inc. requesting inbound LOD for inoperable radar. Prior to departure once in port, send tech report to OCMI to verify proper operation of radar. See narrative.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2004
Resolution: Recieved fax from tech attesting that radar display has been repaired.
Documentation › Logs/Records
Issued 7 November 2002 Resolved
2. IDENTIFY MAINTENENCE FOR RECOVERY BOAT FALL RENEWAL AND TESTING PER COMPANY MAINTENENCE REQUIREMENTS AND SAFETY MANAGEMENT SYSTEM. LEGACY COMPONENT DESC: Transfer Equipment Test/Inspection Records
Condition: Improper/Lack of Maintenance
Due 7 December 2002
Resolved 15 December 2002
Resolution: CLEARED BY ABS TAMPA.
Operations/Management › Drills/Instruction
Issued 7 November 2002 Resolved
3. PROVIDE ACCURATE MAN OVER BOARD EMERGENCY BILLET POSITION FOR RESCUE BOAT MANNING AND OPS, TO PROVIDE TRAINING FOR CREW IN NEW PROCEDURES, AND PROVIDE MSO TAMPA A COPY OF NEW PROCEDURES WITH COMPLETED TRAINING DOCUMENTATION. LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Placed in Improper Service
Due 7 December 2002
Resolved 15 December 2002
Resolution: CLEARED BY ABS TAMPA.
Documentation › Safety Management System
Issued 7 November 2002 Resolved
4. IDENTIFY USE /REQUIREMENT OF TWO (2) EMMERSION SUITS ON SOLAS FORM E. LEGACY COMPONENT DESC: Critical Equipment/Systems ID Procedures
Condition: Unknown
Due 7 December 2002
Resolved 15 December 2002
Resolution: CLEARED BY ABS TAMPA.
Documentation › Safety Management System
Issued 7 November 2002 Resolved
5. PROVIDE CG WITH NON-CONFORMITY FOR ITEMS 2 AND 3 TO MSO TAMPA WITH ITEMS 2-4 TO BE ADDRESSED BY ABS PER ACP. LEGACY COMPONENT DESC: Critical Equipment/Systems ID Procedures
Condition: Unknown
Due 7 December 2002
Resolved 15 December 2002
Resolution: CLEARED BY ABS TAMPA.
Operations/Management › Drug and Alcohol Testing
Issued 7 November 2002 Resolved
1.PROVIDE A COPY OF A CURRENT DRUG TESTING PROGRAM OPERATED BY THE MARINE EMPLOYER (IF ENROLLED IN A CONSORTIUM PROVIDE PROOF OF CONTRACT DATES). LEGACY COMPONENT DESC: Proof of Enrollment
Action required: 705 - Other - as specified
Due 7 December 2002
Resolved 11 December 2002
Resolution: RCV''D COPY OF AMERICAN MARITIME SAFETY DRUG CONSORTIUM CONTRACT GOOD FROM DEC 2002-2003.
Fire Fighting
Issued 8 October 1997 Resolved
PROVE PROPER OPERATION OF TIME DELAYS AS STAMPED ON BOTTLES (30 SEC) IN PRESENCE OF USCG INSPECTORS (CORRECT PRIOR TO 08NOV97)
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
Fire Fighting
Issued 9 October 1996 Resolved
DEMONSTRATE OPERATION OF EMERGENCY FIRE PUMP PHNEUMATIC DISCHARGE VALVE UNDER EMERGENCY GENERATOR OPS. CURRENTLY, DISCHARGE VALVE DOES NOT OPERATE ON VESSEL'S EMERGENCY POWER.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Fire Fighting
Issued 9 October 1996 Resolved
PROVIDE UPDATED FIRE CONTROL PLAN(S) SHOWING THE FOLLOWING REVISIONS (MUST BE APPROVED BY CG MSC): PROPOSED RELOCATION OF MAIN DECK FIRE HOSE STAS TO THE TOP OF THE CATWALK, 3 B-II & BV PORTABLE FIRE EXT IN GENERATOR COMPART,IDENTIFY FIRE DOORS, LOCATION OF SAFETY GEAR/EQUIP LOCKERS (BOW).
Condition: Unknown
Due 13 December 1996
Resolved 13 December 1996
Electrical
Issued 9 October 1996 Resolved
DEMONSTRATE EXTERIOR EMERGENCY LIGHTING AND AFT LIFERAFT EMBARKATION STATION LIGHTING P & S.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Engineering
Issued 9 October 1996 Resolved
PROVE PROPER OPERATION OF SAFETY RELIEF VALVE FOR VARIOUS FUEL VALVES.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Fire Fighting
Issued 9 October 1996 Resolved
LABEL ALL FIRE DAMPERS FOR COMPARTMENT SERVED.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Construction/Loadline
Issued 9 October 1996 Resolved
PROVIDE MARPOL STANDARD DISCHARGE CONNECTION.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Engineering
Issued 9 October 1996 Resolved
PROVIDE APPROVED ASME DATA PLATE FOR #171345 SHIP'S SERVICE AIR RECEIVER.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Fire Fighting
Issued 9 October 1996 Resolved
DEMONSTRATE ALL HEAT SENSOR ALARMS THROUGHOUT VESSEL FOR AN INSPECTOR.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Documentation
Issued 9 October 1996 Resolved
PROVIDE PROOF OF ANNUAL REVIEW OF VESSEL'S SOPEP.
Condition: Unknown
Due 18 November 1996
Resolved 18 November 1996
Fire Fighting
Issued 9 October 1996 Resolved
DEMONSTRATE REPEATER PANEL FOR FIRE DETECTION SYSTEM IN ENGINEROOM.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Deck/Cargo
Issued 9 October 1996 Resolved
MAKE PERMANENT REPAIRS TO BOW THRUSTER VENT DUCTING.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Unknown
Issued 9 October 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 November 1996
Resolved 18 November 1996
Deck/Cargo
Issued 9 October 1996 Resolved
REPLACE MISSING DECK GRATING AT ANCHOR WINDLASSES.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Electrical
Issued 9 October 1996 Resolved
LABEL EMERGENCY LIGHTING WITH MISSING "E".
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Fire Fighting
Issued 9 October 1996 Resolved
DEMONSTRATE OPERATION/SERVICING OF ALL FIRE EXTINGUISHING SYSTEMS_x001C_ (FIXED CO2).
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Engineering
Issued 19 January 1996 Resolved
Modify main engine local control station to permit emergency operation without the use of hand tools.
Condition: Unknown
Due 25 January 1996
Resolved 19 January 1996
Fire Fighting
Issued 19 January 1996 Resolved
Repair inoperable general alarm bells on main/cargo deck._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Engineering
Issued 8 November 1995 Resolved
Submit thermal fluid heater test procedures to USCG for review.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Fire Fighting
Issued 8 September 1995 Resolved
Have fixed fire extinguishing system for galley range hood serviced & provide a servicing report.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Deck/Cargo
Issued 8 September 1995 Resolved
Provide written test procedures for the thermal fluid heater per. 46CFR61.30 & prove operational test of heater per operational procedures.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Electrical
Issued 8 September 1995 Resolved
Emergency gen. switch board 480 VAC is showing ground- investigate & repairas necessary to correct ground.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Electrical
Issued 8 September 1995 Resolved
#3 SSG elec. start button wiring improperly/poorly attached.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Electrical
Issued 8 September 1995 Resolved
#2 SSG elec. start button wiring improperly/poorly attached.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Accommodation/Occupational Safety
Issued 8 September 1995 Resolved
Lower eng. room escape trunk cluttered with gear adrift- clear same.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Construction/Loadline
Issued 8 September 1995 Resolved
Weld hole in blkhd between main eng. room & generator room.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Electrical
Issued 8 September 1995 Resolved
Repair & prove proper operation of ground detection lights on 240VAC panel P201.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Lifesaving
Issued 8 September 1995 Resolved
Replace the two impulse-projected rocket type line throwing apparatus that have no manufacturers date or expiration date of the rockets.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Navigation
Issued 8 September 1995 Resolved
Provide maneuvering information for load conditions on bridge.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Lifesaving
Issued 8 September 1995 Resolved
Replace expired hydrostatic release for port side 406 EPIRB.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Engineering
Issued 8 September 1995 Resolved
Prove proper shut down of HFO-V-24 HFO service tank outlet valve when emergency machinery shut down switch is opened.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Accommodation/Occupational Safety
Issued 8 September 1995 Resolved
Secure storage lockers in eng. control room.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Electrical
Issued 8 September 1995 Resolved
Remove ship's record storage boxes & personnel items stored in elec. room on main deck under stair well.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Engineering
Issued 8 September 1995 Resolved
Prove proper operation of relief valve on UPV #173226 (Manchester) in eng. room, valve did not lift Repair/replace as necessary.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Engineering
Issued 8 September 1995 Resolved
Prove proper operation of relief valve on UPV #59902 (Steel Fab)) in eng. room, tanks 59902 & 59903 are plumbed in series. 59903 lifts first - repair/isolate as necessary.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Lifesaving
Issued 8 September 1995 Resolved
Clean corrosion on general alarm bells located on the weatherdeck & test all alarms after cleaning.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Lifesaving
Issued 8 September 1995 Resolved
Prove proper operation of general alarm bells located on the lifeboat stanchioon port side, pipe tunnel port side just forward of the house, & the bell located on the lifeboat deck at the centerline.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Lifesaving
Issued 8 September 1995 Resolved
Provide waterproof containers for flares in lifeboat.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Navigation
Issued 8 September 1995 Resolved
Add warning statement to bottom of maneuvering sheet.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Construction/Loadline
Issued 8 September 1995 Resolved
Repair inoperable windshield wipers on bridge in front of control station.
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Navigation
Issued 8 September 1995 Resolved
Provide a table of speeds that the bow thruster is effective at and post onbridge.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Lifesaving
Issued 8 September 1995 Resolved
Replace or repaint faded general alarm placards throughout vessel.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Lifesaving
Issued 8 September 1995 Resolved
Remove all flammable/aerosols from aft steering & eng. storage room(ENG AA)to an approved storage container/space per 46CFR35.30-40.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Lifesaving
Issued 19 November 1994 Resolved
Make permanent repairs to lifeboat where cracked near aft keel.
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Lifesaving
Issued 7 October 1994 Resolved
FREE FALL LIFEBOAT SEATING CHANGES AND TESTING TO BE COMPLETED TO THE SATISFACTION OF G-MVI-3.
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994
Construction/Loadline
Issued 7 October 1994 Resolved
VESSEL IS NOT TO CARRY CARGO UNTIL BALLAST/STABILITY ISSUES ARE RESOLVED TOTHE SATISFACTION OF THE USCG MARINE SAFETY CENTER.
Condition: Unknown
Due 8 November 1994
Resolved 8 November 1994
Documentation
Issued 7 October 1994 Resolved
VESSEL MAY NOT OPERATE BEYOND 150 MILES FROM SHORE OR ON AN INTERNATIONAL VOYAGE UNTIL A COPY OF A VALID FCC RADIOTELEGRAPHY CERRTIFICATE TO MSO MORGAN CITY.
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994

Casualty record · 26

26 February 2005Routine · role: Involved in a Marine Casualty · activity 2488044
5 September 2010Routine · role: Involved in a Marine Casualty · activity 3845804
17 January 2012Routine · role: Involved in a Marine Casualty · activity 4229758
11 August 2012Routine · role: Involved in a Marine Casualty · activity 4412755
24 September 2012Routine · role: Involved in a Marine Casualty · activity 4448976
1 November 2013Routine · role: Involved in a Marine Casualty · 1 injured · activity 4766998
24 August 2015Routine · role: Involved in a Marine Casualty · activity 5781504
27 August 2016Routine · role: Involved in a Marine Casualty · 1 injured · activity 6000427
13 July 2017Routine · role: Involved in a Marine Casualty · activity 6208836
7 May 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 6411981
24 October 2018Routine · role: Involved in a Marine Casualty · activity 6567557
5 November 2018Routine · role: Involved in a Marine Casualty · activity 6579066
15 November 2018Routine · role: Involved in a Marine Casualty · activity 6587039
15 December 2018Routine · role: Involved in a Marine Casualty · activity 6601052
15 December 2018Routine · role: Involved in a Marine Casualty · activity 6607957
30 December 2018Routine · role: Involved in a Marine Casualty · activity 6608067
5 March 2019Routine · role: Involved in a Marine Casualty · activity 6637334
5 March 2019Routine · role: Involved in a Marine Casualty · activity 6637340
4 May 2019Routine · role: Involved in a Marine Casualty · activity 6684975
11 June 2019Routine · role: Involved in a Marine Casualty · activity 6719904
29 July 2021Routine · role: Involved in a Marine Casualty · activity 7277823
15 October 2021Routine · role: Involved in a Marine Casualty · activity 7336578
23 November 2023Routine · role: Involved in a Marine Casualty · activity 7838283
11 February 2025Routine · role: Involved in a Marine Casualty · activity 8102417
22 April 2025Routine · role: Involved in a Marine Casualty · activity 8310375
28 December 2025Routine · role: Involved in a Marine Casualty · activity 8290183
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.