Inspection history · 90
28 December 2025
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8287842
28 December 2025
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8290183
5 November 2025
Annual Inspection · ACP Annual Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8240985
24 September 2025
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 8240368
8 June 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8154743
23 April 2025
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8118120
22 April 2025
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8310375
11 February 2025
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8078371
11 February 2025
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8102417
27 January 2025
Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8070615
13 January 2025
ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8062797
13 July 2024
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7957438
28 June 2024
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7944281
21 April 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7899249
23 November 2023
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7828946
23 November 2023
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7838283
22 May 2023
ACP COI Oversight · Administrative Inspection · Re-Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7693932
26 March 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7657077
17 February 2023
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7638390
5 October 2022
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7572453
29 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7440659
28 April 2022
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7440159
26 October 2021
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7340312
15 October 2021
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7333418
15 October 2021
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7336578
5 October 2021
Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7313088
29 July 2021
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7271748
29 July 2021
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7277823
7 January 2021
MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7121234
9 October 2020
Administrative Inspection · ACP Annual Oversight · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7074566
9 October 2020
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7076264
26 May 2020
Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6961578
24 May 2020
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6973293
18 May 2020
ACP Additional Oversight – Risk Assessment
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6956060
6 May 2020
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6949039
3 May 2020
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6949080
3 May 2020
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6950444
12 February 2020
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6908040
23 October 2019
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6840619
21 October 2019
Annual Inspection · ACP Annual Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6838962
1 July 2019
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6733277
11 June 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6719904
4 May 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6684975
25 April 2019
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6689686
9 April 2019
ACP Additional Oversight – Risk Assessment · Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6665981
4 April 2019
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6655631
28 March 2019
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6651035
15 March 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6644416
8 March 2019
ISM Oversight · Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6674565
6 March 2019
Deficiency Check · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6637202
5 March 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6637334
5 March 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6637340
19 February 2019
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6631593
1 February 2019
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6618851
30 December 2018
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6604126
30 December 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6608067
15 December 2018
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6598451
15 December 2018
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6601052
15 December 2018
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6607957
3 December 2018
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6591025
24 November 2018
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6585804
17 November 2018
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6583784
15 November 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6587039
12 November 2018
Administrative Inspection · ISM Oversight
Administrative · Commandant (CG-5P-TI) · Activity 6584249
7 November 2018
Examination of Repairs · ISM SMC Audit · ISM Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6577660
5 November 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6579066
24 October 2018
In-Service Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6567382
24 October 2018
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6567557
16 October 2018
MTSA/ISPS Verification · Re-Inspection · ACP COI Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6542146
6 June 2018
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6435818
7 May 2018
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6409886
7 May 2018
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6411981
16 February 2018
Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6356175
19 January 2018
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6340412
4 January 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6332577
19 December 2017
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6326784
16 December 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6325852
21 November 2017
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6310972
16 November 2017
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6308309
25 October 2017
Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6294898
13 October 2017
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6287331
11 October 2017
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6285815
28 August 2017
Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6253669
13 July 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6208836
24 February 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6093947
19 September 2016
MTSA Verification · ACP Annual Oversight · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6004207
27 August 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6000427
15 August 2016
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5973682
26 February 2016
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5822447
23 January 2016
ISM Oversight
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5804287
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 December 2025
Resolved
74SOLAS20 II-1 26.1
The machinery, boilers, and other pressure vessels,
associates in piping systems and fittings shall be of a
design and construction adequate for the service for
which they are intended and shall be so installed and
protected as to reduce to a minimum any danger to
persons on board die to regard to materials used in
construction, the purpose for which the equipment is
intended, the working conditions to which it will be
subjected to and the environmental conditions on board.
Vessel reported a loss of propulsion during outbound
transit. Vessel must enact permanent repairs to the satisfaction of ABS.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 December 2025
Resolved 29 December 2025
Resolution: Injection pump was replaced and engines tested to the satisfaction of ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 April 2025
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. MI received NRC notification stating vessel's crew discovered oil in the water around the vessel upon arrival to terminal. Oil was determined to originate from a propeller blade seal failure. Provide TPO finding number and technical report from ABS attesting to proper functioning propeller blade seal
74 SOLAS (04) II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2025
Resolved 27 April 2025
Resolution: Preliminary Report provided by ABS. Findning No. 1468.0. Attached in documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 February 2025
Resolved
The applicable standards established by the ABS Marine Vessel Rules may be used as the standard for the design, construction, and testing of main and auxiliary machinery. MI received notification from vessel representative stating vessel experienced loss of propulsion due to a failed sensor on the mechanical overspeed trip mechanism for the main engine. Provide TPO finding number and technical report from ABS attesting to proper operation of the vessel.
46CFR31.35-1
46CFR111.12-1
46CFR58.01-5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2025
Resolved 12 February 2025
Resolution: ABS Preliminary Report provided. Engineering crew replaced the proximity overspeed sensor. Operational test of the sensor was witnessed and considered satisfactory by attending ABS Surveryor.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 January 2025
Resolved
No repairs or alterations affecting the safety of the vessel or its machinery shall be made unless applicable requirements in this chapter are met. Vessel reported newly replaced booster relief valve(V1) failed. Notifications shall be conducted in accordance with the Alternate Compliance Program. Repairs shall be made to the satisfaction of the RO and Coast Guard. Coast Guard Marine Inspector attendance will be required prior to clearing deficiency. Repair report from tech/OEM
and/or RO should discuss root cause and all corrective actions. No movement from the pier authorized unless authorized by the OCMI/COTP.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 February 2025
Resolution: CG MI attendance. See narrative and ABS report.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 January 2025
Resolved
74 SOLAS (97) II-2/15.2
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. #1 fuel supply pump in purifier room was leaking fuel.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2025
Resolved 17 January 2025
Resolution: ABS accepted referral.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 17 January 2025
Resolved
MARPOL 73/78 1/14.2
Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation. OWS was not operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2025
Resolved 17 January 2025
Resolution: ABS accepted referral.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 17 January 2025
Resolved
74 SOLAS (04) II-1/44.2
A second source of energy shall be provided for an additional three starts within 30 minutes. Emergency generator would not start using second source.
Action required: 10 - Deficiency Rectified
Due 17 January 2025
Resolved 17 January 2025
Resolution: Seconnd source of energy was not set at correct pressure. EDG started three time once pressure was set correctly.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 July 2024
Resolved
The main steering gear and rudder stock must be operated by power when necessary to comply with paragraph (b)(2) of this section.
Vessel suffered loss of steering capabilities on the starboard steering gear pump. Prove proper operation of power steering prior to departure from the Gulf Sulphur Services dock in Tampa, FL to the satisfaction of attending ABS class surveyor.
46 CFR 58.25-10(b)(3)
Action required: 17 - Rectify deficiencies prior to departure
Due 13 July 2024
Resolved 16 July 2024
Resolution: Received preliminary survey report from ABS, attesting to satisfactory operation of steering equipment and vessel procedures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 April 2024
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended.
CPP system controls do not operate in "follow up" mode as designed. Repair to the satisfaction of the vessel's classification society and the Coast Guard.
74SOLAS(04)II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2024
Resolved 29 April 2024
Resolution: Repairs completed SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 November 2023
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Vessel stern tube is leaking oil through the seal and into the ocean. Repair to the satisfaction of the vessel's classification society and the Coast Guard.
74 SOLAS (04) II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 November 2023
Resolution: Received class preliminary report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2023
Resolved
Except as provided in paragraph (d) of this section, this subpart applies to each self-propelled vessel that-
(1) Carries oil of any kind as fuel for main propulsion; (2) Is not a tank vessel or is not certificated as a tank vessel; (3) Operates upon the navigable waters of the United States, as defined in 46 U.S.C. 2101(17a); and (4) Is 400 gross tons or more as measured under the convention measurement system in 46 U.S.C. 14302 or the regulatory measurement system of 46 U.S.C. 14502 for vessels not measured under 46 U.S.C. 14302. Vessel must activate NTVRP and notify OSRO prior to transiting.
33 CFR 155.5015
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 November 2023
Resolution: Vessel notified QI.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 5 October 2022
Resolved
A liferaft for use with an approved launching appliance shall: be provided with means for bringing the liferaft alongside the embarkation deck and holding it securely during embarkation.
Marine Inspectors observed that the starboard side davit-launched liferaft cannot be brought alongside the embarkation deck due to its location relative to the installed davit, which was installed to replace an existing davit on September 2021. Additionally, the davit-launched liferaft exceeds the newly installed davit's service workload and therefore requires an approved launching appliance. This deficiency is to be rectified to the satisfaction of the vessel's Recognized Organization. 74SOLAS(97)III/38.4.1.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2022
Resolved 31 October 2022
Resolution: RO (ABS) providing oversight of complete rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 5 October 2022
Resolved
In lieu of meeting the requirements of paragraph 1.1, cargo ships may carry: (In addition to one or more lifeboats) one or more liferafts complying with the requirements of regulation 39 or 40, on each side of the ship, of such aggregate capacity as will accommodate the total number of persons on board.
Marine Inspectors observed life rafts with a capacity of 25 persons, which is less than the 27 total personsallowed onboard per the Certificate of Inspection (COI). Therefore, the vessel is allowed to carry no more than 25 persons onboard. The COI will be amended to reflect this change. 74SOLAS(97)III/26.1.2.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 5 October 2022
14 - Pollution Prevention › 148 - Ballast Water › Ballast water discharge
Issued 28 April 2022
Resolved
Unless otherwise expressly provided...the master, owner, operator, agent, or person in charge of vessels employing a CG approved BWMS must meet the applicable ballast water discharge standard, found in 151.2030 of this subpart, at all times of discharge into the waters of the US. Master of vessel reported discharging of untreated ballast from aft peak tank, which is not IAW with vessels BWMP.
Vessel is prohibited BW discharge of AP tank in US waters, and master must submit contingency plan to verify how the vessel is intending to comply with the BWM requirement to the satisfaction of the local COTP.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2022
Resolved 4 May 2022
Resolution: ABS accepted def and issued finding # 1396.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 October 2021
Resolved
THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. #2 GENERATOR WAS REPORTED INOPERABLE.
74SOLAS(04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2021
Resolved 19 October 2021
Resolution: Deficiency rectfied on receipt of ABS Preliminary Report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 5 October 2021
Resolved
Administrations shall require that records of daily hours of rest of seafarers be maintained in a standardized format, in the working language or languages of the ship and English, to allow monitoring and verification of compliance with the provisions of this section. The seafarers shall receive a copy of the records pertaining to them which shall be endorsed by the master or by a person authorized by the master and by the seafarers.
Identified engineer officers logged import hours while vessel was in transit. Underway watch hours were corrected onscene.
Action required: 10 - Deficiency Rectified
Due 5 October 2021
Resolved 5 October 2021
Resolution: Crew corrected the hours that were improperly listed - all sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 5 October 2021
Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the ORB I so that all entries in the book appropriate to that operation are completed.
Entries in Oil Record Book for sludge tank to tank transfers were entered incorrectly under code (C) 12.1. Tank to tank transfers should be entered under (C) 12.2.
Action required: 10 - Deficiency Rectified
Due 5 October 2021
Resolved 5 October 2021
Resolution: Crew made addtional entry into Oil Record Book correcting the improper entries made - all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 October 2021
Resolved
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency, for a period of 18h emergency lighting: accomodation alleyways, stairway and exits.
Identified 2 interior lights 01 deck & 1 exterior light on the 02 deck that are extinguished.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2021
Resolved 8 October 2021
Resolution: Recieved finding # for the above deficiency. After ABS clears def will upload document into documents section. 11/1/2021 ABS provided documentation clearing def.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 October 2020
Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles. Deck plating in engine room around emergency escape are missing, rendering the emergency escape inaccessible.
74SOLAS(14) II-2/13.1.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2020
Resolved 15 October 2020
Resolution: Received ABS survey report stating deck plating has been replaced and verfied to meet ABS standards. Received pictures from operator verfying replacement.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 October 2020
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual and periodic inspections within the periods specified in 31.10-17 (a) and (b) and your Certificate of Inspection must be endorsed.
Vessel's anniversary date is July 10th. The annual inspection was due by 10OCT2020 to maintain a valid Certificate of Inspection. Prior to conducting cargo operations complete an annual inspection.
46 CFR 31.10-17a
Action required: 705 - Other - as specified
Due 10 October 2020
Resolved 14 October 2020
Resolution: Completed Annual Inspection as required.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 25 April 2019
Resolved
Any ship of 10,000 Gt and above shall be fitted with oil filtering equipment complying with par. 7 of this reg. After reviewing the ORB and speaking with the C/E it was discovered that the OWS has been inpoperable since March 15, 2019. Class (ABS) issued the IOPP but had rcvd no notification of the OWS being inoperable prior to this inspection. Make permanent repairs of the OWS and prove proper working condition.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2019
Resolved 29 April 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 April 2019
Resolved
The main inlets and outlets of all ventilation systems shall be capable of closing from outside the spaces being ventilated. Bow thruster room ventilation closure inoperable in the open position. Make permanenet repairs and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2019
Resolved 29 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 April 2019
Resolved
Fire doors in main vertical zone bulkheads shall be self closing and be capable of self closing with an angle of inclination of up to 35 degrees. Cargo control room door not fully closing when released. Adjust door and prove proper closure. SOLAS CH. II-2 Reg. 9.4.1.1.4.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 25 April 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 April 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Port main deck weather tight door showed day light through gasket when closed. Make neccessary adjusts to ensure weather tight integrity of the door.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 25 April 2019
08 - Alarms › N/A - No Subsystem › General alarm
Issued 25 April 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Upon activation of the general alarm system it was observed that in the pump room the general alarm only produced a visual alarm and no audible. Repair or replace alarm and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 29 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 25 April 2019
Resolved
Maintenance, testing and inspections of life saving appliances shall be carried out based on the guidelines of the organization and in a manner having due regard to ensuring reliability of such appliances. During inspection it was observed that the retro tape on the rescue boat was severly worn and in poor condition, also the fwd painter line for the rescue boat was sun damaged and frayed and in extremely poor condition. Replace as neccessary.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 29 April 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 9 November 2018
Resolved
After 1 July 2002 all vessels shall comply with the International Safety Management (ISM) Code as amended. Preliminary assessment of the vessel’s Safety Management System (SMS).
Interviews with the Master, Chief Engineer, Port Engineer [name withheld] (DPA), along with review of previous internal and external audits provide objective evidence that a SMS has not been fully implemented. Essential elements of the code have not been fully addressed or implemented, additionally non-conformity corrective actions required by the Recognized Organization (RO) in external audits conducted on 28 Dec 2017 and 10 Apr 2018 have not been completed. An external audit, attended by the Coast Guard, is required prior to release from detention.
Action required: 30 - Ship detained
Due 23 November 2018
Resolved 14 November 2018
Resolution: Deficiency cleared
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 9 November 2018
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements, which may be established by the company.
Clear grounds as a result of the vessel having suffered multiple equipment failures, onboard fires & propulsion losses identified in either the below deficiencies or previous vessel history led to an expanded ISM exam revealing the vessel/company did not document and report non-conformities in accordance with the requirements of the ISM Code, and failed to follow procedures for implementing corrective action.
Action required: 30 - Ship detained
Due 23 November 2018
Resolved 14 November 2018
Resolution: Def cleared
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 9 November 2018
Resolved
The Company should identify equipment and technical systems the sudden operational failure of which may result in hazardous situations. The SMS should provide for specific measures aimed at promoting the reliability of such equipment or system. These measures should include the regular testing of stand-by arrangements and equipment or technical systems that are not in continuous use.
The master and DPA stated there was not a list of equipment or technical systems identified as required by the Code. This non-conformity was previously identified by the RO in external audits conducted 28 Dec 2017 and 25 Jan 2018.
Action required: 30 - Ship detained
Due 23 November 2018
Resolved 14 November 2018
Resolution: def cleared
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 9 November 2018
Resolved
The Company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. The various tasks should be defined and assigned to qualified personnel.
Shipboard and company personnel stated that since the requirements of ISM Code, Part A, Clause 10.3 had not been complied with, procedures to address those technical systems and equipment have not yet been established.
Action required: 30 - Ship detained
Due 23 November 2018
Resolved 14 November 2018
Resolution: def cleared
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 9 November 2018
Resolved
Companies should include procedures ensuring non-conformities, accidents and hazardous situations are reported to the Company, investigated and analyzed with the objective of improving safety and pollution prevention.
Since issuance of the vessel’s SMC in Jan 2018 and despite multiple equipment failures, an onboard fire and casualties only two “Event Reports” have been submitted by the vessel. One personnel casualty dated 24 Oct 2018 and one non-conformity dated 28 Oct 2018.
Action required: 30 - Ship detained
Due 23 November 2018
Resolved 14 November 2018
Resolution: def cleared
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 9 November 2018
Resolved
Personnel carrying out audits should be independent of the areas being audited.
The internal audit conducted on the vessel 15-16 Sep 2017 and internal audits conducted on two other company vessels were independently completed by the DPA. These audits included “Findings” that should have been identified as non-conformities, for example; “FMS has not fully been integrated”, “SMS required Crewmember sign-on sheet (MPM Form 3.01) was fond missing from the SMS documentation and not in use” and “SCBAs were reported as not operational, no records of inspection could be found. It was reported by the crew that SCBAs had not worked properly for months."
Action required: 30 - Ship detained
Due 23 November 2018
Resolved 14 November 2018
Resolution: Def cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 November 2018
Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least two generating sets. Vessel Captain reported generator #3 is down for repair, generator #2 intermittently fails to hold the electrical load, and generator #1 is operational but is emitting excessive white smoke. Make permanent repairs and prove proper operation and reliability to the satisfaction of the attending ACP ACS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2018
Resolved 13 November 2018
Resolution: Deficiency was accepted by class and rectified
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 9 November 2018
Resolved
The electrical power available shall be sufficient to supply all those services that are essential for the safety in an emergency, due regard being paid to such services as may have to be operated simultaneously. Vessel Captain reported the emergency generator has failed to pick up the emergency load during vessel blackouts. Make permanent repairs and prove proper operation and reliability to the satisfaction of the attending ACP ACS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2018
Resolved 13 November 2018
Resolution: Deficiency was accepted and rectified by class
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 November 2018
Resolved
The main steering gear shall be so arranged that in the event of loss of steering capability due to a single failure in any part of one of the power actuating systems of the main steering gear, excluding the tiller, quadrant or components service the same purpose, or seizure of the rudder actuators, steering capability shall be regained in not more than 45 s after the loss of one power actuating system. Vessel Captain reported the vessel is experiencing issues with the automatic switching between steering pumps. Make permanent repairs and prove proper operation and reliability to the satisfaction of the attending ACP ACS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2018
Resolved 13 November 2018
Resolution: Deficiency was accepted and rectified by class
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 24 October 2018
Resolved
The vessel's main storage fuel tank, settling tank and day tank have been contaminated with bad fuel causing fuel system to clog and prevent MDE and SSDGs to run properly. Remove contaminated fuel, clean all tanks and restore fuel supply system to satisfactory condition. Provide class report attesting to the proper operation of the fuel supply system.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2018
Resolved 28 October 2018
Resolution: All vsl diesel fuel tanks have been emptied, cleaned and refilled. MI witnessed a two hour operational test of the MDE's and SSDG's fuel supply system, to include separators, buster&service pumps. All systems ran within sat parameters. Class rpt attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 October 2018
Resolved
The vessel has a new/updated Automation system installed. PSTPs need to be updated and approved to reflect new system. Also, until ABS issues final approval and the OCMI witnesses proper operation of the system, PUMS is not authorized.
Action required: 705 - Other - as specified
Resolved 12 February 2020
Resolution: Vessel does not wish to pursue PUMS and PUMS endorsement has been removed from COI.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 16 October 2018
Resolved
Vessel's SMS requires the use of a Fleet Management Software (FMS)(i.e NSE). Vessel is currently using excel spreadsheets as thier preventitive maintenance system which is contrary to the RO approved SMS.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 March 2019
Resolution: Vessel has fully implemented their FMS (NSE). Recieved from ABS a full term SMC and audit report.
Construction/Loadline › Structures › Door
Issued 8 January 2018
Resolved
The knife edge leading into the CO2 room is wasted and no longer capable of maintaining a weather tight seal. Make repairs to the satisfaction of the attending ACP ACS. (reissued from Act # 6326784)
Action required: 705 - Other - as specified
Resolved 28 March 2018
Resolution: Knife edge repaired SAT.
Documentation › Logs/Records › Oil Record Book
Issued 8 January 2018
Resolved
Every ship of 400 GT and above other than an oil tanker shall be provided with an Oil Record Book (ORB) Part 1 (Machinery space operations). The ORB shall be in the form specified in appendix III of MARPOL Annex I. The vessel is maintaining ORB CG-4602A (Rev.01-07). Rev 11-16 is the current version of ORB CG-4602A, which complies with MARPOL. Provide correct version of ORB to the satisfaction of the attending ACP ACS. (reissued from Act # 6326784)
Due 20 January 2018
Resolved 22 March 2018
Resolution: Provided ship with revised ORBs.
Communications › Public Address System › Loudspeaker
Issued 8 January 2018
Resolved
The general emergency alarm system shall be supplemented by either a public address system or other suitable means of communication capable of broadcasting messages into all spaces where crew members are normally present. the installed system is not fully functional. Make repairs and demonstrate functionality to the satisfaction of the attending ACP ACS. (reissued from Act # 6326784)
Action required: 705 - Other - as specified
Due 20 January 2018
Resolved 2 July 2019
Resolution: Rcv'd and accepted Class Report. cleared. Def # 1286 from ABS report.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 4 January 2018
Resolved
Master, chief engineers, chief mates, and second (1st A/E) engineers on chemical tankers shall hold a certificate in advanced training for chemical tanker cargo operations. The chief engineer's MMC is not endorsed as required. Provide onboard as required in compliance with the minimum safe manning document to the satisfaction of the USCG.(reissued from Act # 6326784)
Action required: 10 - Deficiency Rectified
Due 20 January 2018
Resolved 26 April 2018
Resolution: All crew's licenses and endorsements SAT.
Lifesaving › Lifeboat › Propeller
Issued 20 December 2017
Resolved
Before ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. Upon examination, the freefall lifeboat rudder found cracked through at the lower post and in three locations on the rudder skeg. make temp repairs to the satisfaction of the USCG or ACP ACS prior to departure from port.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 December 2017
Resolution: Satisfied attending USCG inspector
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 20 December 2017
Resolved
After Jan 1, 2017 all persons employed or engaged on board vessels to which STCW applies must hold a medical certificate valid for 2 years. Three crew members (AB, DEU, Steward) found on board with expired medical certificates. Provide on board prior to sailing in compliance with the minimum safe manning document to the satisfaction fot the USCG.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 December 2017
Resolution: Vessel met safe manning requirements by providing alternate crew members with applicable certificates.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 20 December 2017
Resolved
On board a seagoing vessel, no person may assign a shipboard duty or responsibility to any person who is assigned a responsibility on the muster list unless the person can produce evidence of having recieved appropriate approved STCW basic training. One crew member (DEU) found on board could not produce evidence of completing approved STCW basic training. Provide on board prior to sailing in compliance with the minimum safe manning document to the satisfaction fot the USCG.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 January 2018
Resolution: Training certificate was produced.
Deck/Cargo › Cargo Stowage › General
Issued 20 December 2017
Resolved
The Detcon Model 10 fixed gas detection system is not functioning as designed and not capable of detecting H2S. Make repairs and prove proper operation to the satisfaction of the attending ACP ACS. IBC Code Ch. 17
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 December 2017
Resolution: Provided satisfactory class report and technician's report attesting to the replacement of malfunctioning fixed gas detection system sensors and functionality of the system.
Construction/Loadline › Structures › Door
Issued 20 December 2017
Resolved
The knife edge leading into the CO2 room is wasted and no longer capable of maintaining a weathertight seal. Make repairs to the satisfaction of the attending ACP ACS.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 January 2018
Resolution: Corrected to USCG satisfaction.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 20 December 2017
Resolved
Any STCW Certificate must be kept available in its original form on board the ship on which the holder is serving. The original certificates for one AB/RFPNW were not available on board, copies were presented for inspection. Provide original certificates (MMC/TWIC/Medical Certificate) on board as required in compliance with the minimum safe manning to the satisfaction of the USCG.
STCW Reg. I/2.11
Condition: Improper/Lack of Maintenance
Due 27 December 2017
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 20 December 2017
Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with the effective means for its operation and control. The RPM gauges for the #2 and 3 SSDGs were not operable and the #1 could not be verified. Make repairs and prove operation to the satisfaction of the attending ACP ACS.
74 SOLAS (1997 Cons.) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 January 2018
Resolved 8 January 2018
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 20 December 2017
Resolved
The machinery shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to hot surfaces and other hazards. Evidence of an exhaust leak noted from the main engine air box. Make repairs to the satisfaction of the attending ACP ACS.
74 SOLAS (1997 Cons.) II-1/26.1
Condition: Improper/Lack of Maintenance
Due 3 January 2108
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Engineering › Sea-water System (primary cooling) › Pump
Issued 20 December 2017
Resolved
The machinery shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts. Safety guards for moving parts associated with the raw water cooling pumps and EDG missing. Install to the satisfaction of the attending ACP ACS.
74 SOLAS (1997 Cons.) II-1/31.1
Condition: Improper/Lack of Maintenance
Due 3 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 20 December 2017
Resolved
Masters, chief engineers, chief mates, and second (1st A/E) engineers on chemical tankers shall hold a certificate in advanced training for chemical tanker cargo operations. The chief engineer's MMC is not endorsed as required. Provide on board as required in compliance with the minimum safe manning document to the satisfaction of the USCG.
STCW Reg. V/1-1.5
Due 20 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 December 2017
Resolved
Upon application for any Certificate of Documentation (COD), the owner of a vessel must designate a hailing port to be marked upon the vessel. The current COD, issued 20 July 2017, reflects a hailing port of Tampa, FL. The stern has been marked Mobile, AL. The stern is to be marked to confirm with the hailing port in accordance with 46 CFR 67.123 to the satisfaction of the USCG.
46 CFR 67.119
Condition: Improper/Lack of Maintenance
Due 3 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Documentation › Certificates/Documents › International Certificate of Fitness (IBC Code)
Issued 20 December 2017
Resolved
International certificates shall be drawn up in a form corresponding to the model given in the respective Convention. Convention certificates reflect the Port of Registry as Mobile, AL. Vessels registration has been updated for Tampa, FL. Provide revised Convention certificates on board to the satisfaction of the USCG.
74 SOLAS (2014 Cons.) I/15 All Ships MARPOL I/9; VI/8; LLC, IAFSC, etc.
Condition: Invalid
Due 3 January 2018
Resolved 11 January 2018
Resolution: Signed [name withheld] provided by ABS.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 20 December 2017
Resolved
Every ship to which chapter I applies shall be issued with a Continuous Synopsis Record (CSR) which shall contain the identification of the Company (as defined in regulation IX/1) the ISM SMC and DOC list the Company ID number as 5951433, whereas the CSR lists 5951671. Revise and provide on board to the satisfaction of the USCG
74 SOLAS (2014 Cons.) XI-1/5
Condition: Improper/Lack of Maintenance
Due 3 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Documentation › Logs/Records › Oil Record Book
Issued 20 December 2017
Resolved
Every ship of 400 GT and above other than an oil tanker shall be provided with an Oil Record Book (ORB) Part 1 (Machinery space operations). The ORB shall be in the form specified in appendix III of MARPOL Annex I. The vessel is maintaining ORB CG-4602A (Rev.01-07). Rev 11-16 is the current version of ORB CG-4602A, which complies with MARPOL. Provide correct version of ORB to the satisfaction of the attending ACP ACS.
MARPOL Annex I/17.1
Condition: Invalid
Due 20 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Communications › Public Address System › Loudspeaker
Issued 20 December 2017
Resolved
The general emergency alarm system shall be supplemented by either a public address system or other suitable means of communication capable of broadcasting messages into all spaces where crew members are normally present. The installed system is not fully functional. Make repairs and demonstrate functionality to the satisfaction of the attending ACS ACS.
74 SOLAS (1997 Cons.) III/4.2
Condition: Improper/Lack of Maintenance
Due 20 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 20 December 2017
Resolved
The 11 April 1995 Stability Letter, cited by the Intl. Load Line Certificate (ILLC), references the ABS approved "Sulphur Enterprise Loading Manual" dated 16 March 1995. This manual could not be located on board. Provide on board or update Stability Letter and ILLC to the satisfaction of the attending ACP ACS.
ILL 66 Art. 16
Condition: Improper/Lack of Maintenance
Due 20 January 2018
Resolved 27 March 2018
Resolution: Deficiency rectified as stated on SAFENET: Full Rectification: It was verified the vessel has marked the life-saving equipment storage with symbols in
accordance with Resolution A.760(18).
Lifesaving › Lifebuoys › Stowage
Issued 20 December 2017
Resolved
Containers, brackets, racks, and other similar stowage locations for life-saving equipment shall be marked with symbols in accordance with Resolution A.760(18), as amended, indicating the devices stowed in that location for that purpose. If more than one device is stowed in a location, the number of devices shall also be indicated. Mark the stowage locations for life-saving equipment as required to the satisfaction of the attending ACP ACS.
74 SOLAS (2014 Cons.) III/20/10 All Ships
Condition: Improper/Lack of Maintenance
Due 30 January 2018
Resolved 27 March 2018
Resolution: Full Rectification It was verified the vessel has marked the life-saving equipment storage with symbols in
accordance with Resolution A.760(18).
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 December 2017
Resolved
Each lifebuoy shall be marked in block capitals with the port of registry of the ship on which it is carried. Mark all life-saving equipment required to be marked with the port of registry to the satisfaction of the attending ACP ACS.
74 SOLAS (1997 Cons.) II/7.1.4
Condition: Improper/Lack of Maintenance
Due 3 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 20 December 2017
Resolved
The lifeboat's stbd. side aft water spray fixture was found inoperable. Make repairs and prove operation of all water spray fixturs to the satisfaction of the attending ACP ACS.
74 SOLAS (2014 Cons.) III/20.2 All ships
Condition: Improper/Lack of Maintenance
Due 3 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 20 December 2017
Resolved
The port side hydraulic ram and associated control piping for the lifeboat davit found with evidence of hydraulic leakages. Make repairs and prove operation to the satisfaction of the attending ACP ACS.
74 SOLAS (2014 Cons.) III.20.2 All ships
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 January 2018
Resolved 25 April 2018
Resolution: Hydraulic rams operational test SAT. No apparant leak.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 20 December 2017
Resolved
Make permanent repairs to the lifeboat rudder, skeg and bearing in accordance with the manufacturer, to the satisfaction of the attending ACP ACS.
74 SOLAS (2014 Cons.) III 20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 February 2018
Resolved 24 April 2018
Resolution: Satisfactory repairs made to vessel's skeg, rudder and bearing.
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 20 December 2017
Resolved
Stbd. side aft mooring chaulk found cracked. Make repairs to the satisfaction of the attending ACP ACS. Repair scheduled to be conducted at drydock.
74 SOLAS (2014. Cons.) I/11
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 March 2018
Resolved 25 April 2018
Resolution: Chaulk replaced in kind. All SAT.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 20 December 2017
Resolved
The Class A boundary between the emergency generator space and the CO2 room found hole and temporarily repairs with epoxy and a doubler. Make permanent repairs to restore integrity of the boundary to the satisfaction of the attending ACP ACS. Repair schedualed to be done at drydock.
74 SOLAS (2014 Cons.) II-2/44.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 March 2018
Resolved 24 April 2018
Resolution: Repaired with insert; SAT. Tested SAT.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 20 December 2017
Resolved
The company should ensure that each ship is manned with qualified, certificated and medically-fit seafarers in accordance with national and international requirements. Section 1.01 of the Savage Marine Management Company Vessel Procedures Manual (VPM)specifies the administrative procedure for crewmember sign-on, including the completion of form VPM F-1.01 (Crew Credentials Checklist). On board verification of crew credentials found the following:
- 03 had expired medical certificates prior to signing-on
- 01 did not have STCW basic training
- 01 did not have endorsement for the required advanced training for chemical tanker cargo operations;
- 01 did not have original certificates on board
No records of form VPM F-1.01 were available for review on board. Following investigation and analysis, Company to provide documentation of corrective action attesting to the implementation of Section 1.01 of the company VPM. The Recognized Organization (ABS) is to attest to the verification of corrective action and conformance to ISM Code A/6.2
74 SOLAS (2014 Cons.) IX/3.1 All Ships // ISM Code Part A/6.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 January 2018
Resolved 26 April 2018
Resolution: Crew's licenses and endorsements SAT.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 16 December 2017
Resolved
Repair/replace low sea chest remote reach rod system. Machinery space to remain manned in accordance with minimally attended machinery space standards with live wach at all times until ACCU notation is restored by the vessel's ACS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2018
Resolved 8 January 2018
Resolution: Deficiency verified corrected by ABS iaw NVIC 02-95 and approved by the CID.
Engineering › Steering Gear System › Pump
Issued 16 November 2017
Resolved
Port steering gear is experencing intermittent alarms causing changeover to stbd steering pump.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 November 2017
Resolution: Revieved satisfactory class report form ABS attesting to the porper opertaion of the port steering gear.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 11 October 2017
Resolved
Provide short term SMS addendum for H2S training and monitoring procedures prior to arrival in Galveston TX. Submit procedures to [name withheld] and MSU Texas City for approval. Cargo operations may not commence until approval.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2017
Resolved 13 October 2017
Resolution: Reviewed risk assessment and contingency plan in regards to inoperable H2S sensor. All submitted documentation found satisfactory.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 20 September 2016
Resolved
Voyage Data Recorder was found and reported to be inoperable. Vessel is restricted to domestic voyages only. SOLAS CH V Reg. 20
Action required: 705 - Other - as specified
Due 27 September 2016
Resolved 28 September 2016
Resolution: Power Distribution Unit replaced.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 23 January 2016
Resolved
Provide liferaft capable of being launched by davit and all necessary arrangements. IAW SOLAS 97 Reg. III / 26.1.2.2
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 February 2016
Resolved 25 February 2016
Resolution: USCG approved davit launch life raft installed with associated launching equipment.
Personnel › Certificates/Documents/Licenses › License, First Assistant Engineer
Issued 23 January 2016
Resolved
Provide onboard first assistant engineer with tankerman endorsement. IAW 46 CFR 15.860(f)(2)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2016
Resolution: Received report from Captain attesting to new First Assistant hire, arrived on board, license checked to verify proper endorsement. All sat.