MAURY USCG vessel records Sign in
← All vessels

TREBLE CLEF

TREBLE CLEF is a 1994 passenger vessel (inspected). The Coast Guard has recorded 113 inspections since 1986, most recently in August 2016, along with 143 deficiencies.

Records from 1986 to 2016. Most recent: inspection, 3 August 2016.

Built
1994
Last inspected
3 August 2016
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA2968
409189
Flag
UNITED STATES
367753930
Maury page id
psix-409189

Inspections, by type

…with no type recorded38
Years with a record 13 calendar years (1986–2016)
The 113 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)276.4 ft × 78.0 ft × 14.0 ft
Registered tonnagegross 2,606 / net 1,882
ITC dimensions (L × B × D)276.4 ft × 78.0 ft × 14.0 ft
ITC tonnagegross 7,180 / net 2,154
BuilderBENDER SHIPYARD INC · MOBILE, AL, UNITED STATES · built 1994
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMemphis, TN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1882 - Regulatory (Subpart C or D), Net Ton
2154 - Convention (Subpart B), Net Ton
2848 - Dead Weight, Ton
2450 - Displacement, Ton
2606 - Regulatory (Subpart C or D), Gross Ton
7180 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI9963MMSI 367753930 · active · compulsorily equipped · granted 8 September 2016, expires 8 September 2026
WDA2968MMSI 366793230 · cancelled · compulsorily equipped · granted 30 November 2000, cancelled 2 November 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

OU 762 Unclassified · MISLE 52491 · 3 December 1997 · activity 99754MISS LAUREN Towing Vessel · MISLE 322374 · 3 December 1997 · activity 99754

Inspection history · 113

3 August 2016 VRP Review · Spot Check · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5961885
1 August 2016 Administrative Inspection · Spot Check · VRP Review
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5959907
6 July 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2703172
28 November 2005 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2541744
26 October 2005 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2522505
5 May 2005 Deficiency Check
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2525693
11 April 2005 Deficiency Check
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2331631
2 March 2005 COI Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2300690
28 September 2004 MTSA Verification
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2207907
30 June 2004 Re-Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2116650
7 May 2004 Construction Oversight
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2062021
16 April 2004 Deficiency Check
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2045501
1 April 2004 Deficiency Check
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2035516
4 March 2004 COI Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2013513
21 January 2004 Quarterly Examination
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1989342
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979490
8 October 2003 Quarterly Examination
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1923775
3 July 2003 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1846793
16 June 2003 Re-Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1818659
9 June 2003 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1813247
8 April 2003 Deficiency Check
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1770115
5 March 2003 COI Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1752597
8 October 2002 Quarterly Examination
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1686805
28 August 2002 Deficiency Check
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1667515
3 July 2002 Re-Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1640641
7 May 2002 Deficiency Check
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1614503
22 April 2002 Deficiency Check
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1608007
4 March 2002 COI Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1490012
12 December 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1412404
2 October 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1379583
5 September 2001 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1072330
23 July 2001 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1069287
13 July 2001 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 34992
13 July 2001 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1067896
3 July 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1403414
9 March 2001 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1067681
9 March 2001 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1469341
27 October 1998 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 803570
27 October 1998 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 808818
9 June 1998 Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 791751
28 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1392851
17 January 1998 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 59984
5 December 1997 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 780170
3 December 1997 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 99754
4 November 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1364442
3 September 1997 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1119977
6 August 1997 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428816
13 May 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 6179
8 May 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1400572
29 January 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1430340
25 November 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 874454
6 November 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1363843
8 October 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1149191
12 September 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1360626
6 August 1996 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1367876
12 July 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1095333
15 June 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 147471
7 June 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1184034
5 May 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442411
13 March 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396477
13 February 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 878464
30 January 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1445039
8 November 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1355541
6 September 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1184512
16 August 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1186500
9 August 1995 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1394355
27 July 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 883664
1 July 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 55384
23 June 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 879726
21 June 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1189801
19 June 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 878350
24 May 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1367392
10 May 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 919
6 May 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 24273
27 April 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1173760
15 April 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 165474
29 March 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1148064
16 March 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 8278
4 March 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 120946
2 March 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 855249
24 February 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 850844
23 February 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1360016
18 February 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 160184
13 February 1995 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 703749
9 February 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 849970
6 February 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 129369
6 February 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1145820
2 February 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419369
17 January 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1174021
11 January 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358645
31 December 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1177897
16 November 1994 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1450932
3 November 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 13988
2 November 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 67992
11 October 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 113478
28 September 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 138029
5 September 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 178967
4 September 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 182991
2 September 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 133171
30 August 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 186502
27 August 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 127706
24 August 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1432837
17 August 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 47762
10 August 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 103750
8 August 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 181410
7 August 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 123748
26 July 1994 Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1157007
19 July 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 17557
18 July 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 138167
13 July 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 21830
10 July 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 78860
9 July 1994 Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1448588
29 August 1986 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1247758

Deficiency record · 143

Fire Fighting › Automatic Sprinkler System › Pressure Tank
Issued 2 March 2005 Resolved
Provide Marine Chemist certificate authorizing safe entrance to void with water tanks for fire suppression system.
Due 16 March 2005
Resolved 16 March 2005
Fire Fighting › Automatic Sprinkler System › Testing Means for Pump
Issued 2 March 2005 Resolved
Provide servicing manual and/or operations manual for fire suppression sprinkler system & demonstrate proper operation of system per manuals. Manual must include line drawing of system. Provide copy of drawing to USCG. 46 CFR 71.25-30 (a)(3)
Due 31 March 2005
Resolved 29 March 2005
Resolution: Received copy of drawing & service manuals on board.
Stability › Watertight Integrity › General
Issued 2 March 2005 Resolved
Demonstrate proper operation of watertight door - door must close between 20-40 seconds. 46 CFR 170.270 (c)
Due 2 April 2005
Resolved 16 March 2005
Resolution: Op test of door satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 March 2005 Resolved
Install lagging on exhaust manifold for bow thruster engine.
Due 30 April 2005
Resolved 30 April 2005
Resolution: Lagging installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 March 2005 Resolved
Install guard on crankshaft for bow thruster engine. 46 CFR 72.40-20 & 58.01-25
Condition: Unknown
Due 2 April 2005
Resolved 11 April 2005
Resolution: Guard installed and found satisfactory.
Engineering › Fuel Oil Storage/Transfer System › Flange
Issued 2 March 2005 Resolved
Replace gasket on port & starboard fuel oil day tanks. 46 CFR 71.25-10
Due 15 April 2005
Resolved 11 April 2005
Resolution: Gasket replaced and found satisfactory.
Engineering › Compressed Air System (control) › Valve
Issued 2 March 2005 Resolved
Demonstrate proper operation of relief valve on #2 air tank. 46 CFR 54.15-10 (g)
Due 16 March 2005
Resolved 16 March 2005
Resolution: Op test satisfactory.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 2 March 2005 Resolved
Provide proper structural fire protection for starboard vertical trunk that runs wiring & non-metallic piping in the engine room. 46 CFR 72.05-10
Due 2 May 2005
Resolved 2 May 2005
Resolution: SPF in vertical trunk installed and found satifactory.
Electrical › Electrical Distribution System (service) › Fuse
Issued 2 March 2005 Resolved
Provide distribution box with isolation breakers for feeder cables to battery box in the bow thruster room. 46 CFR 111.50-3 (f)
Due 2 April 2005
Resolved 11 April 2005
Resolution: Distribution box installed and found satisfactory.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 2 March 2005 Resolved
Demonstrate proper operation of alarms/sensors for the propulsion & electrical engines. 46 CFR 58.05-10
Due 16 March 2005
Resolved 16 March 2005
Resolution: Op test satisfactory.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 2 March 2005 Resolved
Demonstrate shutdown of emergency generator with the CO2 system. 46 CFR 112.50-1
Due 16 March 2005
Resolved 16 March 2005
Resolution: Conducted operational test - shutdown worked as designed.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 2 March 2005 Resolved
Submit proposal for a well ventilated area for the batteries beneath the deck plates in the engine room. 46 CFR 111.15
Due 2 April 2005
Resolved 29 March 2005
Resolution: Proposal submitted and found satisfactory.
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 2 March 2005 Resolved
Provide documentation stating the design parameters of the switchboard. 46 CFR 111.30
Due 16 March 2005
Resolved 16 March 2005
Resolution: Plan provided.
Engineering › Pressure Vessel › Coast Guard Symbol
Issued 2 March 2005 Resolved
Conduct hydrostatic test of water tanks for fire suppression sprinkler system in the pressence of USCG. 46 CFR 54.10
Due 30 April 2005
Resolved 30 April 2005
Resolution: Hydrostatic test completed with satisfactory results.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 March 2005 Resolved
Provide test procedures for elevators from the servicing technician. 46 CFR 111.91-1
Due 16 March 2005
Resolved 16 March 2005
Lifesaving › Rescue Boat
Issued 4 March 2004 Resolved
Make permanent repairs to hull fracture in bow rescue boat. LEGACY COMPONENT DESC: Hull (rigid)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 April 2004
Resolved 16 April 2004
Resolution: Repairs to rescue boat sat.
Fire Fighting › Structural - A Class Divisions
Issued 4 March 2004 Resolved
Ensure Fire Screen Door #14 closes properly. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 1 April 2004
Resolution: Door closes properly.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 4 March 2004 Resolved
Prove proper operation of machinery space CO2 suppression time delay. LEGACY COMPONENT DESC: Operating Controls
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 1 April 2004
Resolution: Witnessed sat test.
Fire Fighting › Structural - A Class Divisions
Issued 4 March 2004 Resolved
Make repairs to door in A Class bulkhead, starboard side entry to bar on second deck. LEGACY COMPONENT DESC: Openings - Doors
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 23 April 2004
Resolution: Door latches installed.
Navigation › Piloting/Steering
Issued 4 March 2004 Resolved
Install magnetic compass LEGACY COMPONENT DESC: Magnetic Compass
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 16 March 2004
Resolution: Compass installed
Lifesaving › Rescue Boat Equipment
Issued 4 March 2004 Resolved
Label oars with the vessel name. LEGACY COMPONENT DESC: Paddle/Oar
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 16 March 2004
Resolution: Oars properly labled.
Lifesaving › Rescue Boat
Issued 4 March 2004 Resolved
Provide cover for battery box in bow rescue boat. LEGACY COMPONENT DESC: Weathertight Stowage
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 16 March 2004
Resolution: Cover for battery box provided.
Fire Fighting › Automatic Sprinkler System
Issued 4 March 2004 Resolved
Prove proper operation of sprinkler system and associated alarms. LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 16 March 2004
Resolution: Sprinkler pump operations and associated alarms tested sat.
Electrical › Lighting (emergency)
Issued 4 March 2004 Resolved
Provide temporary emergency lighting in all rest rooms and starboard side of chiller room. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 16 March 2004
Resolution: TLE installed in all noted locations.
Fire Fighting › Fire Hoses
Issued 4 March 2004 Resolved
Demonstrate ability to reach aft generator space with two fire hoses. LEGACY COMPONENT DESC: Length
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 16 March 2004
Resolution: Hose stations provided with 1.5 in 75 ft hose. Adequate to meet generator space.
Documentation › Certificates/Documents
Issued 4 March 2004 Resolved
CORF expired 21 Jan 2004 due to vessel operators internal administrative error. Insurance coverage was continuous. Vessel operators able to obtain a renewal on 03 Mar 2004. LEGACY COMPONENT DESC: Certificate of Financial Responsibility
Action required: 17 - Rectify deficiencies prior to departure
Due 4 March 2004
Resolved 4 March 2004
Resolution: Vessel operators obtained renewal. Confirmed by MSD Quad Cities with NPFC. New COFR number 850 441-17
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 16 June 2003 Resolved
Provide proper brackets for each portable fire extinguisher as needed. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2003
Resolved 16 August 2003
Resolution: Proper brackets installed
Electrical › Electrical Distribution System (service)
Issued 5 March 2003 Resolved
Provide approved cable transit from emergencty generator room to elevator shaft. LEGACY COMPONENT DESC: Distribution Panel Bus
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2003
Resolved 5 April 2003
Electrical › Electric Generation Source (emergency)
Issued 5 March 2003 Resolved
Repair ground test button on emergency generator switchboard LEGACY COMPONENT DESC: Ground Detection
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2003
Resolved 3 April 2003
Electrical › Electric Generation Source (emergency)
Issued 5 March 2003 Resolved
Repair visual overspeed alarm on emergency generator LEGACY COMPONENT DESC: Overcurrent Device
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2003
Resolved 9 April 2003
Resolution: Bulb replaced. Visual alarm functioning.
Engineering › Fuel Oil Storage/Transfer System
Issued 5 March 2003 Resolved
Repair as required soft patch on fuel line in emergency generator room LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2003
Resolved 3 April 2003
Fire Fighting › Automatic Sprinkler System
Issued 5 March 2003 Resolved
Repair as required soft patch on sprinkler line in emergency generator room LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2003
Resolved 3 April 2003
Electrical › Electric Supply System (service)
Issued 5 March 2003 Resolved
Correctly utilize Rox with on wire per hole on first deck LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 5 April 2003
Resolved 3 April 2003
Electrical › Electrical Distribution System (service)
Issued 5 March 2003 Resolved
Replace broken breaker in electrical panel in bow thruster room LEGACY COMPONENT DESC: Circuit Breaker
Action required: 705 - Other - as specified
Due 5 April 2003
Resolved 3 April 2003
Electrical › Electrical Distribution System (service)
Issued 5 March 2003 Resolved
Ensure all electrical panels are properly marked LEGACY COMPONENT DESC: Distribution Panel Bus
Action required: 705 - Other - as specified
Due 5 April 2003
Resolved 3 April 2003
Electrical › Lighting (service)
Issued 5 March 2003 Resolved
Repair ground fault cover on main lighting panel LEGACY COMPONENT DESC: Ground Detection
Action required: 705 - Other - as specified
Due 5 April 2003
Resolved 3 April 2003
Pollution Prevention/Response › Prevention Equipment
Issued 5 March 2003 Resolved
Repair bilge alarm in port Z drive LEGACY COMPONENT DESC: Bilge Monitor
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2003
Resolved 3 April 2003
Electrical › Electrical Distribution System (service)
Issued 5 March 2003 Resolved
Prove proper operation of #2 SSDG high temp alarm LEGACY COMPONENT DESC: Panelboard
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2003
Resolved 3 April 2003
Electrical › Electrical Distribution System (service)
Issued 8 October 2002 Resolved
Ensure power cabeling in port stern engine room is secured iaw 46 CFR subchapter J LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Action required: 705 - Other - as specified
Due 8 November 2002
Resolved 8 November 2002
Fire Fighting › Structural - A Class Divisions
Issued 8 October 2002 Resolved
Ensure outside port stern 2nd deck door closes properly iaw 46 cfr 72.05-25 LEGACY COMPONENT DESC: Openings - Doors
Action required: 705 - Other - as specified
Due 8 November 2002
Resolved 8 November 2002
Fire Fighting › Structural - A Class Divisions
Issued 3 July 2002 Resolved
Ensure proper operation of door latches first deck stbd stern, third deck stbd mid, and first deck port stern iaw 46CFR72.05-25 LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 28 August 2002
Fire Fighting › Means of Escape
Issued 3 July 2002 Resolved
Ensure proper operation of exit light on third deck stbd fwd IAW 46CFR77.05-1 LEGACY COMPONENT DESC: Escape Route Signs
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 28 August 2002
Fire Fighting › Structural - Horizontal Zones
Issued 3 July 2002 Resolved
Ensure proper fire protection on second deck cage rox blocks iaw 46CFR72.05-10
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 28 August 2002
Fire Fighting › Means of Escape
Issued 4 March 2002 Resolved
Engine office space emergency exit was blocked. Closure needs readjusting LEGACY COMPONENT DESC: Doorways
Condition: Unknown
Due 6 March 2002
Resolved 6 March 2002
Fire Fighting › Structural - A Class Divisions › Doors
Issued 4 March 2002 Resolved
Engine Office Space main door closure needs adjustment
Due 5 March 2002
Resolved 5 March 2002
Fire Fighting › Structural - A Class Divisions › Doors
Issued 4 March 2002 Resolved
Engine Office Space remove tie back from main door
Due 5 March 2002
Resolved 5 March 2002
Electrical › Electric Supply System (service) › Cable
Issued 4 March 2002 Resolved
#2 Void heater cabling needs to be installed with metal banding.
Due 5 March 2002
Resolved 5 March 2002
Fire Fighting › Structural Fire Protection - General
Issued 4 March 2002 Resolved
#2 Void, reinstall mineral wool LEGACY COMPONENT DESC: Structural Bulkhead Construction
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 6 March 2002
Fire Fighting › Ventilation Systems
Issued 4 March 2002 Resolved
Make permanent repairs to elevator equipment room ventilation. LEGACY COMPONENT DESC: Fans
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 22 April 2002
Fire Fighting › Structural - A Class Divisions
Issued 4 March 2002 Resolved
Repair FSD #10 & 11, 8 & 9 (needs to close properly) LEGACY COMPONENT DESC: Openings - Fire Doors
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 6 March 2002
Electrical › Lighting (emergency)
Issued 4 March 2002 Resolved
Office space on 4th deck has insufficient emergency lighting LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 7 May 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 4 March 2002 Resolved
Instal machinery guard on paddle wheel over belt/pulley, also on bow thruster mover.
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 22 April 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 4 March 2002 Resolved
Submit Vital Autmation Test procedures for approval.
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 22 April 2002
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 4 March 2002 Resolved
Mount electrical recepticals throughout the vessel.
Due 4 March 2002
Resolved 5 March 2002
Electrical › Electric Supply System (service) › Cable
Issued 4 March 2002 Resolved
Secure loose cable in EOS
Due 4 March 2002
Resolved 5 March 2002
Fire Fighting › Structural - Main Vertical Zones
Issued 4 March 2002 Resolved
Make proper electrical penetrations in all A/C electrical rooms throughout vessel.
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 7 May 2002
Electrical › Electric Generation Source (emergency)
Issued 4 March 2002 Resolved
Demonstrate full shutdown of emergency generator after activation of overspreed and low oil pressure trips. LEGACY COMPONENT DESC: Generator
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 22 April 2002
Electrical › Electric Generation Source (service)
Issued 4 March 2002 Resolved
Repair/Replace #3 Generator oil pressure guage. LEGACY COMPONENT DESC: Generator
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 22 April 2002
Electrical › Electric Generation Source (service)
Issued 4 March 2002 Resolved
Make repairs to #2 Generator starter LEGACY COMPONENT DESC: Generator
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 22 April 2002
Electrical › Electrical Distribution System (service)
Issued 4 March 2002 Resolved
Place deadend cabling in junction box in sprinkler void, and in void #6 LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 4 March 2002
Resolved 6 March 2002
Lifesaving › Lifebuoys
Issued 4 March 2002 Resolved
Label all ring life buoy stations LEGACY COMPONENT DESC: Stowage
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 22 April 2002
Operations/Management › FireFighting
Issued 4 March 2002 Resolved
Ensure fire control plan is accurate
Action required: 705 - Other - as specified
Due 4 March 2002
Resolved 6 March 2002
Electrical › Electrical Distribution System (service)
Issued 4 March 2002 Resolved
Remove dead end cable in bow thruster room LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 6 March 2002
Fire Fighting › Structural - A Class Divisions
Issued 4 March 2002 Resolved
Ensure doors to crew spaces shut properly. LEGACY COMPONENT DESC: Openings - Doors
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 22 April 2002
Fire Fighting › Ventilation Systems
Issued 4 March 2002 Resolved
Repair power ventilation shutdown system. LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Due 6 April 2002
Resolved 7 May 2002
Construction/Loadline
Issued 12 December 2001 Resolved
Provide proper piping installation for the main deck port side air handeling room IAW NVIC 9-97.
Condition: Unknown
Due 4 March 2002
Resolved 4 March 2002
Resolution: Corrected
Fire Fighting
Issued 2 October 2001 Resolved
Re-install cable transit in deck in main deck portside A/C room.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Navigation
Issued 23 July 2001 Resolved
Failure of follow up steering controller. Vessel to remain moored at dock until repairs completed.
Condition: Unknown
Due 6 August 2001
Resolved 6 August 2001
Electrical
Issued 3 July 2001 Resolved
Install blank in cutout in main switchboard.
Condition: Unknown
Due 9 July 2001
Resolved 12 July 2001
Accommodation/Occupational Safety
Issued 28 January 1998 Resolved
PROVIDE APPROVED SHIPBOARD AND SHORESIDE EMERGENCY EVACUATION PLAN(S) PRIORTO EMBARKING ANY PASSENGERS.
Condition: Unknown
Due 28 January 1998
Resolved 28 January 1998
Construction/Loadline
Issued 5 December 1997 Resolved
Make proper repairs to damage to rub rail at frame 49 port side. Notifiy this office prior to doing any welding ro burning with passengers onboard.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Fire Fighting
Issued 6 August 1997 Resolved
INSTALL AND TEST SMOKE DETECTORS WITHIN ELEVATOR SHAFTS.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Electrical
Issued 29 January 1997 Resolved
INSTALL AND PROVE PROPER OPERATION OF LOSS OF LUBE OIL SHUTDOWN ON EMERGENCY GENERATOR.
Condition: Unknown
Due 29 January 1997
Resolved 29 January 1997
Lifesaving
Issued 29 January 1997 Resolved
INSTALL PROPER 12 VOLT MARINE BOW AND STERN LIGHTS ON BOTH RESCUE BOATS.
Condition: Unknown
Due 29 January 1997
Resolved 29 January 1997
Lifesaving
Issued 29 January 1997 Resolved
PROVIDE ANTI-EXPOSURE (MUSTANG) SUITS FOR ALL RESCUE BOAT PERSONNEL (4).
Condition: Unknown
Due 29 January 1997
Resolved 29 January 1997
Electrical
Issued 6 August 1996 Resolved
PROVE PROPER OPERATION OF TEMPERATURE ALARMS & SHUTDOWNS ON #3 GENERATOR.
Condition: Unknown
Due 6 August 1996
Resolved 6 August 1996
Electrical
Issued 6 August 1996 Resolved
INSTALL VISUAL ALARM INDICATORS FOR TEMPERATURE ALARM/SHUTDOWN FOR #3 GENERATOR IN CONTROL BOOTH.
Condition: Unknown
Due 6 August 1996
Resolved 6 August 1996
Fire Fighting
Issued 6 August 1996 Resolved
REPLACE A-15 DOORS TO CREDIT OFFICE AND BEVERAGE LOCKER. WIRE GLASS INSERTS GREATER THAN 100 SQUARE INCHES. MUST BE LESS THAN 100 SQUARE INCHES.
Condition: Unknown
Due 6 August 1996
Resolved 6 August 1996
Lifesaving
Issued 6 August 1996 Resolved
MODIFY VENTILLATION IN EMERG. GEN. ROOM TO ALLOW EASIER OPENING OF EXIT DOORS IN EVENT OF CO2 DISCHARGE. AT ALL TIMES SPACE IS OCCUPIED DURING GENERATOR OPERATION, PERSONNEL MUST BE STATIONED OUTSIDE SPACE TO SHUTDOWN GENERATOR TO ALLOW PERSONNEL TO ESCAPE.
Condition: Unknown
Due 6 August 1996
Resolved 6 August 1996
Fire Fighting
Issued 6 August 1996 Resolved
CORRECT AEVADS MESSAGING AND ZONING. CURRENT ARRANGEMENT IS INCORRECT IN STAIR TOWERS AND EXTERIOR DECKS.
Condition: Unknown
Due 6 August 1996
Resolved 6 August 1996
Electrical
Issued 5 May 1996 Resolved
Remove all tape across any circuit breaker and properly label breaker usage, electrical lighting panel 8P203.
Condition: Unknown
Due 8 June 1996
Resolved 25 June 1996
Electrical
Issued 5 May 1996 Resolved
Properly label all breakers: electrical panel P206 HVAC_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 June 1996
Resolved 25 June 1996
Fire Fighting
Issued 13 March 1996 Resolved
REMOVE THERMAL INSULATION FROM OVERHEAD OF MAIN ENGINE ROOM AND PROPERLY INSULATE TO A-60 STANDARDS.
Condition: Unknown
Due 13 March 1996
Resolved 13 March 1996
Fire Fighting
Issued 13 March 1996 Resolved
ENSURE PIPE PENETRATIONS THROUGH "A" CLASS BULKHEADS & DECKS ARE INSULATED TO SAME STANDARD IAW NVIC 6-80 FOR 12" BACK. (SEE MINS FOR LOCATIONS)
Condition: Unknown
Due 13 March 1996
Resolved 13 March 1996
Fire Fighting
Issued 13 March 1996 Resolved
INSULATE BULKHEADS OF SODA DISPENSING ROOM TO A-60 IAW FIRE BULKHEAD DESIGNATION PLAN.
Condition: Unknown
Due 13 March 1996
Resolved 13 March 1996
Electrical
Issued 13 March 1996 Resolved
REPLACE PLASTIC WIRE TIES ON VERTICAL WIRE RUN IN PIPE/ELECTRICAL CHASE ON PORT SIDE HURRICANE DECK.
Condition: Unknown
Due 13 March 1996
Resolved 13 March 1996
Fire Fighting
Issued 13 March 1996 Resolved
OVERHEAD OF PIPE/ELECTRICAL CHASE ON PORT SIDE UPPER DECK HAS MISSING/LOOSEA-60 INSULATION.
Condition: Unknown
Due 13 March 1996
Resolved 13 March 1996
Fire Fighting
Issued 13 March 1996 Resolved
REVISE FIRE BULKHEAD DESIGNATION PLAN TO SHOW STORAGE ROOM ON PORT SIDE OF MAIN DECK DELI.
Condition: Unknown
Due 13 April 1996
Resolved 1 April 1996
Fire Fighting
Issued 13 March 1996 Resolved
INSULATE PORT SECTION OF FWD BULKHEAD OF SURVEILANCE ROOM TO A-60 STANDARDSIAW FIRE BULKHEAD DESIGNATION PLAN.
Condition: Unknown
Due 13 March 1996
Resolved 13 March 1996
Fire Fighting
Issued 30 January 1996 Resolved
Install 1 1/4 inch buttons on pins holding A-60 insulation.
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996
Electrical
Issued 30 January 1996 Resolved
Secure two wires in surveillance space in overhead to keep wires off of drop ceiling.
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996
Electrical
Issued 30 January 1996 Resolved
Prove proper operation of emergency generator low lube oil alarm.
Condition: Unknown
Due 30 January 1996
Resolved 30 January 1996
Fire Fighting
Issued 30 January 1996 Resolved
Provide tamper switches on backup fire pump's water supply in accordance with NVIC 10-93 if applicable.
Condition: Unknown
Due 30 January 1996
Resolved 30 January 1996
Fire Fighting
Issued 30 January 1996 Resolved
Prove proper capacity of backup sprinkler pump (fire pump) in accordance with NVIC 10-93 if applicable.
Condition: Unknown
Due 30 January 1996
Resolved 30 January 1996
Electrical
Issued 30 January 1996 Resolved
Properly terminate dead end wire in surveillance space located along recording equipment.
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996
Electrical
Issued 30 January 1996 Resolved
Provide A-0 through A-60 integrity throughout the vessel. (Nylon stuffing nuts)
Condition: Unknown
Due 30 January 1996
Resolved 30 January 1996
Fire Fighting
Issued 30 January 1996 Resolved
Install proper A-60 packing to beverage line penetrations in soda room leaving huricane deck to Texas deck.
Condition: Unknown
Due 30 January 1996
Resolved 30 January 1996
Fire Fighting
Issued 30 January 1996 Resolved
Install A-60 insulation returns on all pipes on A-60 bulkhead in surveillance space.
Condition: Unknown
Due 30 January 1996
Resolved 30 January 1996
Lifesaving
Issued 9 August 1995 Resolved
PROVIDE AND INSTALL DATA PLATE ON BOTH RESCUE BOATS IAW 46 CFR 160.056-6.
Condition: Unknown
Due 8 September 1995
Resolved 22 August 1995
Accommodation/Occupational Safety
Issued 9 August 1995 Resolved
PROVE HOT PLATES IN DELI MEET UL 197 AND THE MARINE SUPPLEMENT IAW _x001C_ 46 CFR 111.77-3.
Condition: Unknown
Due 8 September 1995
Resolved 6 September 1995
Fire Fighting
Issued 24 May 1995 Resolved
PROVIDE MEANS FOR AUTOMATIC START-UP OF BACK-UP SPRINKLER PUMP IN CASE OF FAILURE OF PRIMARY SPRINKLER PUMP IAW NFPA 13 & NVIC 10-93.
Condition: Unknown
Due 24 May 1995
Resolved 24 May 1995
Fire Fighting
Issued 24 May 1995 Resolved
INSTALL FIRE DEPT. CONNECTIONS ON BOTH SIDES OF VESSEL FOR SPRRINKLER SYSTEM IAW NVIC 10-93 & NFPA 13, INCLUDING INTERNATIONAL SHORE CONNECTION.
Condition: Unknown
Due 24 May 1995
Resolved 24 May 1995
Fire Fighting
Issued 24 May 1995 Resolved
PROVIDE MEANS FOR REMOTE OPERATION OF SECONDARY FIRE PUMP IN THE EVENT ACCESS BLOCKED BY ENGINE ROOM FIRE.
Condition: Unknown
Due 24 May 1995
Resolved 24 May 1995
Fire Fighting
Issued 24 May 1995 Resolved
PROVIDE INSPECTION, TESTING & MAINTENANCE LOG FOR SPRINKLER SYSTEM IAW NFPA25 AND 46 CFR 76.25-35(j).
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Accommodation/Occupational Safety
Issued 24 May 1995 Resolved
REPAIR MOTORIZED CONTROL VALVES TO CHILLER UNITS.
Condition: Unknown
Due 24 May 1995
Resolved 24 May 1995
Engineering
Issued 27 April 1995 Resolved
PROVE PROPULSION IS INSTALLED IN ACCORDANCE WITH APPROVED PLANS.
Condition: Unknown
Due 27 April 1995
Resolved 27 April 1995
Electrical
Issued 23 February 1995 Resolved
PROVIDE INSTRUCTIONS AND PROCEDURES TO SECURE POWER TO SHIPS MAIN SWITCHBOARD FROM SHORE BREAKERS.
Condition: Unknown
Due 2 March 1995
Resolved 20 March 1995
Lifesaving
Issued 23 February 1995 Resolved
INSTALL AND PROVE PROPER OPERATION OF POWER OPERATED WINCHES FOR BOTH RESCUE BOATS.
Condition: Unknown
Due 23 March 1995
Resolved 20 March 1995
Engineering
Issued 23 February 1995 Resolved
PROVE OPERATION OF ENGINE LOW OIL PRESSURE FAILURE SWITCHES ON ALL DIESEL ENGINES.
Condition: Unknown
Due 23 February 1995
Resolved 23 February 1995
Engineering
Issued 23 February 1995 Resolved
INSTALL A REMOTE FUEL SHUTOFF VALVE FOR NEW DIESEL ENGINE INSTALLATION.
Condition: Unknown
Due 23 March 1995
Resolved 20 March 1995
Electrical
Issued 23 February 1995 Resolved
LABEL SPRINKLER PUMP POWER SUPPLY PANEL(EMERGENCY & NORMAL SOURCE)
Condition: Unknown
Due 2 March 1995
Resolved 20 March 1995
Electrical
Issued 23 February 1995 Resolved
PROVE OPERATION OF ALL GENERATOR OVERSPEED DEVICES.
Condition: Unknown
Due 23 February 1995
Resolved 23 February 1995
Fire Fighting
Issued 17 January 1995 Resolved
Maintain the original approved integrity of all structural fire protection boundries(decks and bulkheads) penetrated by new wiring and any other penetrations made to facilitate gaming equipment movement. Make same available to a Coast Guard Marine Inspector.
Condition: Unknown
Due 17 January 1995
Resolved 17 January 1995
Documentation
Issued 17 January 1995 Resolved
Submit full calculations for fire load, stability, and the modified Emergency Egress Proceedures to the Commanding Officer, Marine Safety Center, 400 Seventh Street S.W., Washington, D.C. 20590 for review and approval.
Condition: Unknown
Due 17 January 1995
Resolved 17 January 1995
Engineering
Issued 11 January 1995 Resolved
INSTALL INSULATION TO EXHAUST PIPING & MUFFLER UNITS INSIDE #3 S/S DIESEL GENERATOR ENCLOSURE SPACE.
Condition: Unknown
Due 10 February 1995
Resolved 13 February 1995
Construction/Loadline
Issued 11 January 1995 Resolved
MODIFICATIONS TO VESSEL'S GAMING ARRANGEMENT AND THE CONSTRUCTION OF "B" CLASS BULKHEADS WITHIN THE P/S STAIRTOWERS HAS NOT BEEN SUBMITTED OR APPROVED. REMOVE BULKHEADS AND PROVIDE APPROVAL FROM MSC FOR ALL OTHER MODIFICATIONS.
Condition: Unknown
Due 10 February 1995
Resolved 10 February 1995
Lifesaving
Issued 11 January 1995 Resolved
INSTALL DECK PLATE INSIDE #3 S/S DIESEL ENCLOSURE SPACE TO REMOVE TRIP HAZARD.
Condition: Unknown
Due 10 February 1995
Resolved 13 February 1995
Engineering
Issued 11 January 1995 Resolved
INSTALL CONTAINMENT DRIP PANS UNDER FUEL FILTERS (RACOR) SYSTEM TO #3 S/S DIESEL GENERATOR & EMERGENCY DIESEL GENERATOR. INSTALL CONTAINMENT DRIP PANS UNDER #1 & #2 S/S DIESEL GENERATORS FUEL FILTERS (RACORS) IN THE ENGINE ROOM.
Condition: Unknown
Due 10 February 1995
Resolved 13 February 1995
Fire Fighting
Issued 11 January 1995 Resolved
INSTALL A VENTILLATION CLOSURE PLATE TO SHUTOFF AIR FLOW FROM SPACE IN THE EVENT CO2 SYSTEM IS OPERATED. CLOSURE SHOULD CLOSE WITH LOUVERS AND FAN SHOULD STOP.
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Lifesaving
Issued 11 January 1995 Resolved
ENTRANCE/EXIT DOOR TO #3 S/S DIESEL ENCLOSURE SHOULD NOT LOCK PERSONNEL INSIDE. MAKE LOCK MECHANISM WORK WHERE PERSONNEL CAN EXIT FROM INSIDE SPACE.
Condition: Unknown
Due 10 February 1995
Resolved 13 February 1995
Engineering
Issued 11 January 1995 Resolved
LABEL #3 S/S GENERATOR FUEL OIL TANK WITH REQUIRED SAFETY MARKINGS.
Condition: Unknown
Due 10 February 1995
Resolved 10 February 1995
Engineering
Issued 11 January 1995 Resolved
REPAIR & PROVE PROPER OPERATION OF HYDRAULIC PUMPS FOR PADDLEWHEEL PROPULSION SYSTEM.
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Deck/Cargo
Issued 11 January 1995 Resolved
CORRECT UNSAT MOORING ARRANGEMENT TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 February 1995
Resolved 13 February 1995
Lifesaving
Issued 16 November 1994 Resolved
MODIFY APPROVED UNDERWAY/SHORSIDE EEP IN ACCORDANCE WITH USCG COMMENTS THISVISIT.
Condition: Unknown
Due 30 November 1994
Resolved 21 February 1995
Electrical
Issued 16 November 1994 Resolved
PROVIDE APPROVED ELECTRICAL MATTING FOR EMERGENCY GENERATOR IN ACCORDANCE WITH 46 CFR 111.30.
Condition: Unknown
Due 16 November 1994
Resolved 16 November 1994
Fire Fighting
Issued 16 November 1994 Resolved
REMOVE JOINER BULKHEADS INSTALLED IN FOYER/LANDING AREA ON THE P/S SIDES ONHURRICANE DECK IN THE STAIR TOWERS; OR OBTAIN APPROVAL FROM MSC.
Condition: Unknown
Due 16 November 1994
Resolved 16 November 1994
Electrical
Issued 16 November 1994 Resolved
PROVIDE DETAILED PLAN OF ACTION W/REGARD TO INSTALLATION OF 3RD GENERATOR IAW 46 CFR 71.65-10(a).
Condition: Unknown
Due 16 November 1994
Resolved 16 November 1994
Fire Fighting
Issued 16 November 1994 Resolved
INSTALL PROPER A-60 FIRE STOP IN AFT ELEVATOR MACHINERY ROOM HOLD LEVEL.
Condition: Unknown
Due 21 February 1995
Resolved 21 February 1995
Fire Fighting
Issued 16 November 1994 Resolved
ADJUST AND PROVE PROPER OPERATION OF ALL FIRE SCREEN DOORS AND ASSOCIATED HARDWARE.
Condition: Unknown
Due 21 February 1995
Resolved 21 February 1995
Documentation
Issued 24 August 1994 Resolved
Prior to installing a third generator on the main deck, port side aft, provide the Marine Safety Center with a weight estimate and calculation of adjusted light ship characteristics to account for the installation of the generator. (Issued per MSO NOLA CID ltr dtd 11 Oct 94)
Condition: Unknown
Due 9 December 1994
Resolved 10 February 1995
Documentation
Issued 24 August 1994 Resolved
PROVIDE TO THE SATISFACTION OF THE OCMI AN UPDATED DRAWING OF THE FIRE CONTROL PLAN IAW 46CFR 71.65-5(D).
Condition: Unknown
Due 24 September 1994
Resolved 28 October 1994
Documentation
Issued 24 August 1994 Resolved
PROVIDE "VESSEL SPECIFIC" INSTRUCTIONS FOR SPRINKLER SYSTEM AND AMEND MANUAL TO INCLUDE OPERATION, TESTING, MAINTENANCE, AND RESET INSTRUCTIONS, PER 46CFR76.25-35(J)
Condition: Unknown
Due 24 September 1994
Resolved 28 October 1994
Fire Fighting
Issued 24 August 1994 Resolved
REPLACE LOW VELOCITY WATER FOR NOZZLES WITH TYPE REQUIRED BY 46CFR 162.027-2(C).
Condition: Unknown
Due 26 August 1994
Resolved 30 September 1994
Documentation
Issued 24 August 1994 Resolved
Upon review and acceptance of the vessel's damage stability by the Marine Safety Center, install and prove proper operation of the 650 KW generator set in accordance with approved plans. (Requirement issued iaw MSO NOLA ltrdtd 11Oct94)
Condition: Unknown
Due 9 December 1994
Resolved 10 February 1995
Fire Fighting
Issued 24 August 1994 Resolved
PROVIDE VALVE HANDLE/WRENCH FOR GATE VALVE INSTALLED IN SHORESIDE FIREMAIN SUPPLY LINE.
Condition: Unknown
Due 26 August 1994
Resolved 30 September 1994
Construction/Loadline
Issued 9 July 1994 Resolved
PROVIDE MANUFACTURES INSTALLATION SPECIFICATION FOR CLASS 3 WATERTIGHT DOORIN CREW HOLD AREA WITH REGARD TO INSTALLATION OF REMOTE HAND OPERATION.
Condition: Unknown
Due 9 July 1994
Resolved 9 July 1994
Documentation
Issued 9 July 1994 Resolved
Prove propulsion is installed in accordance with approved plans.
Condition: Unknown
Due 9 July 1994
Resolved 9 July 1994
Documentation
Issued 9 July 1994 Resolved
PROVIDE PLANS FOR INSTALLATION OF THIRD GENERATOR.
Condition: Unknown
Due 9 September 1994
Resolved 28 October 1994
Documentation
Issued 9 July 1994 Resolved
Provide approved plans for installed propulsion.
Condition: Unknown
Due 28 February 1995
Resolved 26 September 1994
Navigation
Issued 9 July 1994 Resolved
SATISFY LIMITED BRIDGE VISIBILITY ISSUE PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 9 July 1994
Resolved 9 July 1994
Documentation
Issued 9 July 1994 Resolved
Prove proper operation of reverse power relays and sat. installation of third generator in accordance with approved plans. Status of all plans regarding installation of the third generator are per [name withheld] ltr dtd 02Jun94 regarding the 3rd generator.
Condition: Unknown
Due 9 September 1994
Resolved 28 October 1994
Documentation
Issued 9 July 1994 Resolved
Provide certificate of documentation on board.
Condition: Unknown
Due 9 August 1994
Resolved 26 September 1994
Engineering
Issued 9 July 1994 Resolved
Conduct full sea trials prior to getting underway
Condition: Unknown
Due 9 July 1994
Resolved 9 July 1994

Ownership record