This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
571 - Simplified, Net Ton
328 - Displacement, Gross Ton
734 - Dead Weight, Gross Ton
571 - Simplified, Gross Ton
Maury page id
psix-41013
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
Cargo Pump Engine #1 cargo pump shaft penetration is not gas tight allowing the potential chance of hazardous vapors to enter a non-class 1 division 1 machinery space. (46 CFR 32.50-1). Cargo pump engine shaft penetration needs to be gas tight.
Due 12 June 2014
Resolved 28 May 2014
Resolution: Received a email showing the #1 Cargo Pump shaft penetration with a new installed bellow surrounding it. This is to prevent vapors from entering a Non-Class1 Division 1 space.
Lifesaving › Lifefloat › Float-free Link
Issued 24 August 2012Resolved
Vessel does not have proper weak link for LF, must provide proper float free arrangement. 07 Sept vessel ordered part and requested def due ext.
Due 28 September 2012
Resolved 19 May 2015
Resolution: This def should have been cleared back in 2012. New liferafts have been installed since then and multiple inspections have occurred which would have checked proper liferaft installation.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 September 2011Resolved
The company must have an approval from MSC of the Hazardous Area Plan to demonstrate compliance with 46 CFR 111.105.
Action required: 705 - Other - as specified
Due 16 November 2011
Resolved 16 November 2011
Resolution: Hazardous Area Plan has been approved by MSC.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 April 2010Resolved
Vessel failed to complete dry dock and ISE on time.
Action required: 705 - Other - as specified
Due 5 April 2010
Resolved 5 April 2010
Resolution: Completed dry dock and ISE.
Lifesaving › Lifefloat › Serviceable
Issued 27 March 2007Resolved
Repair lifefloat apparatus holes on underside
Condition: Improper/Lack of Maintenance
Due 26 April 2007
Resolved 23 April 2007
Resolution: New lifefloat provided.
Engineering › Fuel Oil Service System › Hose
Issued 10 January 2006Resolved
Various F/O hoses on goth generators are of improper material. Replace improper hose IAW 46CFR56.60-25(b).
Condition: Improper/Lack of Maintenance
Due 10 February 2006
Resolved 18 January 2006
Resolution: Subject hoses replaced.
Properly mark all lifesaving equipment IAW 46CFR199.640
Condition: Improper/Lack of Maintenance
Due 17 January 2006
Resolved 18 January 2006
Resolution: Lifebuoys properly marked.
Lifesaving › Lifefloat › Serviceable
Issued 10 January 2006Resolved
Lifefloat is damaged. Cover has failed in several areas. Retro reflective tape requires renewal. Missing painter and weak link. Missing boat hook. Repair/replace lifefloat and equipment.
Condition: Improper/Lack of Maintenance
Due 17 January 2006
Resolved 18 January 2006
Resolution: Lifefloat replaced, properly marked, and rigged with painter, weak link, and paddles.
Action required: 705 - Other - as specified
Resolved 15 March 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 March 2005Resolved
Repair/replace missing lagging , Generator Engine
Condition: Improper/Lack of Maintenance
Due 7 April 2005
Resolved 22 March 2005
Lifesaving › Hand Flares › Not on Board
Issued 2 March 2005Resolved
Replace expired flares with current flares. Prior to LBS voyage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 March 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 March 2005Resolved
Repair Air compressor Charger amp meter. Prior to use of the same.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 March 2005
Documentation
Issued 30 January 2001Resolved
Vsl was found operating for 53 days with an expired COI from 08Dec00 to 30Jan01. During the inspection for cert: Found Oil Record Book Part II was missing entries for cargo operations between 11Dec00 and 02Jan01; 30 days of DOI's were not on board as req by 33 CFR 155.820(d) and 156.150(f).
Condition: Unknown
Due 30 January 2001
Resolved 7 February 2001
Lifesaving
Issued 8 December 1998Resolved
remove wood from fwd rake, deck and wood shelving
Condition: Unknown
Due 15 January 1999
Resolved 15 January 1999
Engineering
Issued 8 December 1998Resolved
install guard over fanbelt pulley
Condition: Unknown
Due 15 January 1999
Resolved 15 January 1999
Electrical
Issued 1 February 1996Resolved
REPAIR EXHAUST LEAKS STBD ENG AT BOTH EXHAUST MANIFOLD CONNECTIONS.
Condition: Unknown
Due 1 February 1996
Resolved 1 February 1996
Electrical
Issued 1 February 1996Resolved
INSTALL LAGGING ON EXHAUST 671 GM ENGINE EXHAUST PIPING
Condition: Unknown
Due 1 February 1996
Resolved 1 February 1996