Records from 1985 to 2016. Most recent: inspection, 30 November 2016.
Inspection history · 39
30 November 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6049742
19 May 2015
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5129464
9 May 2014
COI Inspection · MTSA Verification · Internal Structural Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4854018
24 August 2012
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4420676
26 September 2011
COI Inspection · Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4160618
6 January 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3922030
5 April 2010
Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3709187
13 January 2010
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3663074
22 December 2009
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3654122
8 April 2009
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3448199
4 March 2008
Cargo Tank Internal · Internal Structural Exam · DAPI Audit · Periodic Inspection · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3157933
27 March 2007
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2895799
11 August 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2743883
15 March 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2603059
3 February 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2578901
10 January 2006
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2563916
14 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2309860
2 March 2005
Deficiency Check · MTSA Verification · Cargo Tank Internal · Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2302368
26 May 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2079167
26 April 2004
Periodic Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2052916
9 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1962420
6 March 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1753467
4 March 2003
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1754982
27 January 2003
Annual Inspection · Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1735680
1 February 2002
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1482526
14 February 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 715353
30 January 2001
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1449416
9 February 2000
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1470547
16 April 1999
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 790277
8 December 1998
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 808174
8 January 1998
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 779081
8 January 1998
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1114461
18 December 1996
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1097316
25 April 1996
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1081092
10 April 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 452711
1 February 1996
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1182899
1 September 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 874270
3 January 1995
Hull Examination · COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 963108
25 November 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 995007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 9 May 2014
Resolved
Cargo Pump Engine #1 cargo pump shaft penetration is not gas tight allowing the potential chance of hazardous vapors to enter a non-class 1 division 1 machinery space. (46 CFR 32.50-1). Cargo pump engine shaft penetration needs to be gas tight.
Due 12 June 2014
Resolved 28 May 2014
Resolution: Received a email showing the #1 Cargo Pump shaft penetration with a new installed bellow surrounding it. This is to prevent vapors from entering a Non-Class1 Division 1 space.
Lifesaving › Lifefloat › Float-free Link
Issued 24 August 2012
Resolved
Vessel does not have proper weak link for LF, must provide proper float free arrangement. 07 Sept vessel ordered part and requested def due ext.
Due 28 September 2012
Resolved 19 May 2015
Resolution: This def should have been cleared back in 2012. New liferafts have been installed since then and multiple inspections have occurred which would have checked proper liferaft installation.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 September 2011
Resolved
The company must have an approval from MSC of the Hazardous Area Plan to demonstrate compliance with 46 CFR 111.105.
Action required: 705 - Other - as specified
Due 16 November 2011
Resolved 16 November 2011
Resolution: Hazardous Area Plan has been approved by MSC.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 April 2010
Resolved
Vessel failed to complete dry dock and ISE on time.
Action required: 705 - Other - as specified
Due 5 April 2010
Resolved 5 April 2010
Resolution: Completed dry dock and ISE.
Lifesaving › Lifefloat › Serviceable
Issued 27 March 2007
Resolved
Repair lifefloat apparatus holes on underside
Condition: Improper/Lack of Maintenance
Due 26 April 2007
Resolved 23 April 2007
Resolution: New lifefloat provided.
Engineering › Fuel Oil Service System › Hose
Issued 10 January 2006
Resolved
Various F/O hoses on goth generators are of improper material. Replace improper hose IAW 46CFR56.60-25(b).
Condition: Improper/Lack of Maintenance
Due 10 February 2006
Resolved 18 January 2006
Resolution: Subject hoses replaced.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 10 January 2006
Resolved
Various engine installations have non-jacketed exhaust piping without proper insulation, Properly insulate exhaust systems IAW 46CFR58.10-5(d).
Condition: Improper/Lack of Maintenance
Due 10 February 2006
Resolved 3 February 2006
Resolution: Vessel properly installed insulation as required.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 January 2006
Resolved
Properly mark all lifesaving equipment IAW 46CFR199.640
Condition: Improper/Lack of Maintenance
Due 17 January 2006
Resolved 18 January 2006
Resolution: Lifebuoys properly marked.
Lifesaving › Lifefloat › Serviceable
Issued 10 January 2006
Resolved
Lifefloat is damaged. Cover has failed in several areas. Retro reflective tape requires renewal. Missing painter and weak link. Missing boat hook. Repair/replace lifefloat and equipment.
Condition: Improper/Lack of Maintenance
Due 17 January 2006
Resolved 18 January 2006
Resolution: Lifefloat replaced, properly marked, and rigged with painter, weak link, and paddles.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 March 2005
Resolved
Repair floodlight prior to night cargo ops
Action required: 705 - Other - as specified
Resolved 15 March 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 March 2005
Resolved
Repair/replace missing lagging , Generator Engine
Condition: Improper/Lack of Maintenance
Due 7 April 2005
Resolved 22 March 2005
Lifesaving › Hand Flares › Not on Board
Issued 2 March 2005
Resolved
Replace expired flares with current flares. Prior to LBS voyage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 March 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 March 2005
Resolved
Repair Air compressor Charger amp meter. Prior to use of the same.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 March 2005
Documentation
Issued 30 January 2001
Resolved
Vsl was found operating for 53 days with an expired COI from 08Dec00 to 30Jan01. During the inspection for cert: Found Oil Record Book Part II was missing entries for cargo operations between 11Dec00 and 02Jan01; 30 days of DOI's were not on board as req by 33 CFR 155.820(d) and 156.150(f).
Condition: Unknown
Due 30 January 2001
Resolved 7 February 2001
Lifesaving
Issued 8 December 1998
Resolved
remove wood from fwd rake, deck and wood shelving
Condition: Unknown
Due 15 January 1999
Resolved 15 January 1999
Engineering
Issued 8 December 1998
Resolved
install guard over fanbelt pulley
Condition: Unknown
Due 15 January 1999
Resolved 15 January 1999
Electrical
Issued 1 February 1996
Resolved
REPAIR EXHAUST LEAKS STBD ENG AT BOTH EXHAUST MANIFOLD CONNECTIONS.
Condition: Unknown
Due 1 February 1996
Resolved 1 February 1996
Electrical
Issued 1 February 1996
Resolved
INSTALL LAGGING ON EXHAUST 671 GM ENGINE EXHAUST PIPING
Condition: Unknown
Due 1 February 1996
Resolved 1 February 1996