Records from 1994 to 2017. Most recent: inspection, 6 September 2017.
Inspection history · 26
6 September 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6261276
13 December 2016
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6057127
9 May 2012
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4305835
12 March 2010
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3694183
26 March 2009
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3440541
12 March 2009
Deficiency Check · COI Inspection · MTSA/ISPS Verification · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3432131
6 October 2008
Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3342368
28 May 2008
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3220089
12 June 2007
Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2958101
26 October 2006
Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2808491
15 June 2006
Annual Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2680640
2 June 2005
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2384023
6 April 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2038539
25 March 2004
Construction Oversight · MARPOL Annex I Examination · Initial Certification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2030903
28 October 2002
MARPOL Annex I Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1696989
29 March 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 816442
14 October 1999
MARPOL Annex I Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 788341
3 March 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 799387
31 July 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1130511
3 March 1998
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1120174
4 February 1998
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1445307
1 February 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1121801
11 December 1996
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 186547
2 December 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449983
21 February 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1193228
28 December 1994
Hull Examination · Initial Certification · Construction Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355074
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 9 May 2012
Resolved
Generator on upper deck that powers deck equipment does not have fire extinguisher immediately available.
Due 8 June 2012
Resolved 11 May 2012
Resolution: Installed B-II extinguisher
Construction/Loadline › Structures › Scuttle
Issued 9 May 2012
Resolved
Escape scuttle hatch cover from machinery space needs to have the assist spring tension adjusted. Hatch is difficult to open.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2012
Resolution: cleaned and reset tension spring
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 May 2012
Resolved
PFD storage bin outside the upper level control booth has holes in the bottom sides and has standing water in the bottom..
Due 8 June 2012
Resolved 11 May 2012
Resolution: Repaired holes and remounted bin.
Engineering › Pressure Vessel › Relief Valve
Issued 12 March 2009
Resolved
Valves need to be bench tested/replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2009
Resolved 25 March 2009
Resolution: Inspected
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 12 March 2009
Resolved
Fuel oil/lube oil tank sight glasses need to be glass.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 April 2009
Resolved 25 March 2009
Resolution: Replaced
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 28 May 2008
Resolved
Renew operating controls box on E/R entry bulkhead.
Condition: Improper/Lack of Maintenance
Due 13 June 2008
Resolved 5 June 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 28 May 2008
Resolved
Mount extinguisher on aft deck near paint locker.
Due 13 June 2008
Resolved 5 June 2008
Communications › Radio Communications › VHF Radiotelephone
Issued 28 May 2008
Resolved
Provide backup batteries for liferaft radios.
Due 13 June 2008
Resolved 5 June 2008
Lifesaving › Inflatable Liferafts › Servicing
Issued 28 May 2008
Resolved
Provide maintenance certificate for life rafts.
Due 13 June 2008
Resolved 5 June 2008
Operations/Management › Drills/Instruction › Abandon Ship
Issued 12 June 2007
Resolved
Provide Abandoning ship liferaft deployment instructions.
Due 12 July 2007
Resolved 29 June 2007
Resolution: Provided
Personnel › Certificates/Documents/Licenses › MMD, Lifeboatman
Issued 12 June 2007
Resolved
Provide 3 certified lifeboatmen for vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2007
Resolution: Members with endorsements provided and verified; SAT.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 12 June 2007
Resolved
Stow all portable fire extinguishers properly.
Due 12 July 2007
Resolved 29 June 2007
Resolution: Completed.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 12 June 2007
Resolved
Install IMO stickers for emergency egress.
Due 12 July 2007
Resolved 29 June 2007
Resolution: IMO decals indicated egress routes in place.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 12 June 2007
Resolved
Label all emergency lighting with proper decal.
Due 12 July 2007
Resolved 29 June 2007
Resolution: Completed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 June 2007
Resolved
Remove all excess wiring from state rooms.
Due 12 July 2007
Resolved 29 June 2007
Resolution: Removed.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 12 June 2007
Resolved
Provide First Aid Kit sufficient for amount of personnel authorized by COI.
Due 12 July 2007
Resolved 29 June 2007
Resolution: Large First Aid kit provided.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 12 June 2007
Resolved
Provide sufficient amount of fire and safety plans throughout vessel for on board personnel.
Due 12 July 2007
Resolved 29 June 2007
Resolution: Abundant plans (showing egress routes) now in place.
Fire Fighting › Means of Escape › Blocked
Issued 12 June 2007
Resolved
Repair rusted and broken escape hatch for engine room.
Due 12 July 2007
Resolved 29 June 2007
Resolution: Completed; operates freely as intended.
Stability › Watertight Integrity › General
Issued 12 June 2007
Resolved
Stencil watertight door with proper markings to remain closed except for transit.
Due 12 July 2007
Resolved 29 June 2007
Resolution: WTD stenciled.
Stability › Watertight Integrity › General
Issued 12 June 2007
Resolved
Install rubber gasket on watertight door.
Due 12 July 2007
Resolved 29 June 2007
Resolution: New door gaskets installed and tested sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 June 2007
Resolved
Install bilge alarms in engine room, adequate for any list of vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2007
Resolution: Bilge alarm (loud hailer on main deck) installed.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 June 2007
Resolved
Service OWS and provide verifying documentation.
Due 12 July 2007
Resolved 29 June 2007
Resolution: Green Marine serviced, tested and provided invoice for OWS. SAT.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 12 June 2007
Resolved
Cap open pipes and valves on oil sludge tank.
Due 12 July 2007
Resolved 29 June 2007
Resolution: Pipe caps porvided.
Electrical › Electric Generation Source (service) › Generator
Issued 12 June 2007
Resolved
Provide certificate from generator manufacturer of proper reverse power relay and testing protocol.
Due 12 July 2007
Resolved 29 June 2007
Resolution: Reviewed email and technical info on genset / main board. Determined that board was designed to provide automatic trip out of generator upon parallel operation. Time delay of less than a second after parallel is competed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 12 June 2007
Resolved
Install warning light in engine room for operation of Fixed CO2 system.
Due 12 July 2007
Resolved 29 June 2007
Resolution: Completed.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 June 2007
Resolved
Provide operation manual for OWS.
Due 12 July 2007
Resolved 29 June 2007
Resolution: Manual attached to OWS. SAT
Fire Fighting › Fire Hoses › Condition
Issued 12 June 2007
Resolved
Provide missing spanners wrenches for fire stations.
Due 12 July 2007
Resolved 29 June 2007
Resolution: Completed.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 12 June 2007
Resolved
Provide oil transfer procedures.
Due 12 July 2007
Resolved 29 June 2007
Resolution: Oil transfer procedures available but they were lacking piping diagram / valve placement. Discussed with superintendent and he assured me that the procedures would be updated to include these items.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 12 June 2007
Resolved
Provide Periodic Test Procedures.
Due 12 July 2007
Resolved 29 June 2007
Resolution: Procedures provided, however they are incomplete. I discussed what was needed on test procedures and the difference between test "procedures" and test "results". The barge superintendent assured me this item would be corrected immediately.
Construction/Loadline
Issued 4 February 1998
Resolved
Damage noted IWO #3S and #4S fender casings and longitudinal rails. Noted extreme steel stress & cracked welds along vertical seam of fender casing. Required to crop and renew all damaged material by 04MAR98.
Condition: Unknown
Due 4 February 1998
Resolved 4 February 1998