MAURY USCG vessel records
← All vessels

JAX-SAN JUAN BRIDGE

JAX-SAN JUAN BRIDGE is a 1984 freight barge. The Coast Guard has recorded 108 inspections since 1985, most recently in August 2026, along with 196 deficiencies, 1 operational control and 8 casualty investigations between 2004 and 2021.

Records from 1985 to 2026. Most recent: inspection, 4 August 2026.

Built
1984
Last inspected
4 August 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 4 August 2026
…with no type recorded27
Operational controls None recorded without a removal date
Years with a record 40 calendar years (1985–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

229118
Flag
UNITED STATES
Maury page id
psix-229118

Documentation record

Registered dimensions (L × B × D)699.2 ft × 104.0 ft × 20.0 ft
Registered tonnagegross 12,078 / net 10,525
ITC dimensions (L × B × D)699.2 ft × 104.0 ft × 20.0 ft
ITC tonnagegross 35,086 / net 10,525
BuilderMARINE POWER & EQUIPMENT · SEATTLE, WA, UNITED STATES · built 1984
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 15 December 2025 · expires 31 December 2026
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35086 - Convention (Subpart B), Gross Ton
12078 - Regulatory (Subpart C or D), Gross Ton
10525 - Convention (Subpart B), Net Ton
10525 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 8

Inspection history · 108

4 August 2026 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8455109
16 April 2026 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8351254
29 May 2025 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8147420
28 June 2024 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7944532
15 March 2024 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7879540
26 January 2024 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7856211
26 June 2023 Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7724234
9 May 2022 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7446911
26 April 2022 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7438368
10 December 2021 Examination of Repairs · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7361453
9 December 2021 Annual Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7365156
12 October 2021 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7330900
11 October 2021 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7336352
21 September 2021 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7316857
24 May 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7205556
13 January 2021 Drydock Extension
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7123831
9 June 2020 Annual Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6966126
27 March 2019 COI Inspection · MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6650517
8 May 2018 Annual Inspection · Internal Structural Exam · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6411946
10 April 2018 Damage Survey · In-Service Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6389038
10 April 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6392316
12 June 2017 MARPOL Annex I Examination · Annual Inspection · Administrative Inspection · MARPOL Annex VI Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6173547
2 May 2017 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6137973
22 March 2017 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6109776
18 November 2016 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6069344
31 May 2016 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5892609
18 March 2016 MARPOL Annex II Examination · Annual Inspection · MARPOL Annex VI Survey · Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5835813
6 July 2015 MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5175836
2 July 2014 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4908390
30 April 2014 Examination of Repairs · Welding Related Inspections Qualification Testing · Administrative Inspection · Damage Survey · In-Service Inspection · Deficiency Check · Plan Review (Other than "T")
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4847475
9 April 2014 Deficiency Check · COI Inspection · MARPOL Annex I Examination · Administrative Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4831599
27 September 2013 Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4724405
27 August 2013 Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4698405
6 June 2012 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4336281
12 April 2012 Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4272310
19 August 2011 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4120282
20 May 2010 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3738165
8 April 2010 Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3709888
22 January 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3668227
4 January 2010 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3658152
25 September 2009 Administrative Inspection · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3604711
24 September 2009 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3614040
9 April 2009 MARPOL Annex I Examination · MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3448061
9 March 2009 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3430091
8 January 2009 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3411823
22 October 2008 Deficiency Check · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3349461
17 July 2008 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3270684
19 June 2008 Re-Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3241576
16 April 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3192321
19 July 2007 MARPOL Annex I Examination · MTSA/ISPS Verification · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2970404
21 March 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2606631
13 February 2006 COI Inspection · Examination of Repairs · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2584488
24 January 2006 Hull Examination · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2572279
8 July 2005 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2419445
25 May 2005 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2367807
12 January 2005 Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2273392
15 September 2004 Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2198426
15 September 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2241804
15 April 2004 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2044746
23 January 2004 Internal Structural Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1992900
6 February 2003 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1740696
8 February 2002 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1485085
23 March 2001 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1061300
22 February 2001 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1059047
24 January 2001 MARPOL Annex II Examination · COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1421999
2 March 2000 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1470249
27 May 1999 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 801444
2 April 1999 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1122473
21 January 1999 COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1365002
26 June 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 97409
25 June 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 792972
19 May 1998 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1126540
19 February 1998 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1120316
5 February 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 679888
21 January 1997 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1104110
11 December 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 186547
19 July 1996 Hull Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1377727
26 February 1996 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 885126
31 January 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1193135
23 May 1995 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1182771
1 March 1995 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 856442
1 February 1995 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 832007
30 March 1994 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 856325
17 March 1994 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1165068
16 March 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 164116
16 March 1994 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1165053
15 February 1994 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 853078
25 October 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 110283
11 August 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 527541
17 March 1993 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 832093
3 March 1993 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 831921
2 March 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 174058
18 February 1993 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 835055
29 April 1992 Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1270619
5 March 1992 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1007708
19 February 1992 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 944343
4 February 1992 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 943645
19 February 1991 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 931320
27 June 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 909373
13 November 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1293997
13 September 1989 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1037418
8 August 1989 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 973514
21 July 1989 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1345254
24 December 1986 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1309003
24 April 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 445241
23 April 1986 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1307004
14 February 1986 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 439093
3 July 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 989518

Deficiency record · 196

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 October 2021 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs which affects the safety of the vessel. The survey shall be such as to ensure that the necessary repairs or renewals have been effectively made and are in all respects satisfactory. Provide survey and repair proposal for approval by Coast Guard Marine Inspectors.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 November 2021
Resolved 9 November 2021
Resolution: Temporary repair. Proposed permanent repair scheduled for 08DEC21 dry dock.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 September 2021 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2021
Resolution: Temporary repair was made, PTP was issued.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 April 2019 Resolved
Complete worklist items NLT 30JUN19.
Action required: 705 - Other - as specified
Due 30 June 2019
Resolved 6 November 2019
Resolution: Recieved notifaction that all worklist items have been repair.
Construction/Loadline › Hull › Hull Plating
Issued 11 April 2018 Resolved
Make permanent repairs to fracture found below the waterline in Void space 2, one frame aft of the forward watertight bulkhead.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 11 April 2018
Resolved 12 April 2018
Resolution: Permanent repairs have been made to the satisfaction of the attending marine inspector.
Construction/Loadline › Penetrations › Weld
Issued 11 April 2018 Resolved
Make repairs to pin hole found in watertight bulkhead in between voids 2 & 3.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 11 April 2018
Resolved 12 April 2018
Resolution: Permanent repairs have been made to the satisfaction of the attending marine inspector.
Construction/Loadline › Penetrations › Weld
Issued 10 April 2018 Resolved
Make permanent repairs to crack found on stbd side shell going into void space 3 to the satisfaction of the attending marine inspector. ILLC 66
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2018
Resolved 12 April 2018
Resolution: Permanent repairs have been made to the satisfaction of the attending marine inspector.
Electrical › Electric Generation Source (service) › Generator
Issued 23 May 2016 Resolved
Vessel rep could not demonstrate proper operation of low lube oil and overspeed shut downs on port gen-set
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 31 May 2016
Electrical › Electrical Distribution System (service) › Cable
Issued 20 June 2014 Resolved
Properly secure dead end cable hanging down ofrom 3rd deck ovherad aft, center of barge.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Engineering › Fuel Oil Service System › Valve
Issued 20 June 2014 Resolved
Renew or replace leaking F/O Supply Solenoid and Solenoid Bypass valves for port generator.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Construction/Loadline › Structures › Superstructure
Issued 20 June 2014 Resolved
Insert port side curtain 3rd window aft from bow.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Electrical › Lighting (service) › Lighting Fixture
Issued 20 June 2014 Resolved
Replace packing gland on Fr 19 1/2 stbd side light fixture.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 June 2014 Resolved
Properly secure receptacle at Fr 25 1/2 2nd deck port side.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Electrical › Electrical Distribution System (service) › Cable
Issued 11 June 2014 Resolved
Properly pack the main cable transit leading into the port generator room as to prevent the ingress of water onto the switchboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2014
Electrical › Electric Generation Source (service) › Generator
Issued 11 June 2014 Resolved
Remove all excess oil from the starboard generator and cables in the starboard generator room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2014
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 June 2014 Resolved
Provide lagging on the starboard generator exhaust from the manifold to the flex joint.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2014
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 June 2014 Resolved
Provide a distribution panel of the dead-front type, to replace the un-serviceable "Ramp Level 2 Panel" on the 2nd deck port aft side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2014
Electrical › Lighting (service) › Lighting Fixture
Issued 11 June 2014 Resolved
Ensure all light fixtures are properly mounted throughout the vessel.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Electrical › Electrical Distribution System (service) › Junction Box
Issued 11 June 2014 Resolved
Ensure all junction boxes are properly mounted throughout the vessel.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Electrical › Electrical Distribution System (service) › Cable
Issued 11 June 2014 Resolved
Provide support for all cables and wires every 24" in all vertical, horizontal and overhead locations and band all wires and cables with fire retardant material.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Electrical › Electrical Distribution System (service) › Cable
Issued 11 June 2014 Resolved
Provide chaffing or supports where cables and wires pass through snipes so as to prevent chaffing.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Electrical › Electrical Distribution System (service) › Cable
Issued 11 June 2014 Resolved
Properly pack cable glands in the following locations: 3rd deck port ramp control for lane 4 & 6, and 8 & 10, 2nd deck cables going into Refrigeration Panel R5.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Electrical › Electrical Distribution System (service) › Switchboard
Issued 11 June 2014 Resolved
Either blank off, or provide a handle for the lead select on the port switchboard.
Action required: 705 - Other - as specified
Due 17 July 2014
Resolved 19 June 2014
Electrical › Electrical Distribution System (service) › Switchboard
Issued 11 June 2014 Resolved
Properly mount the front covers of the port and starboard switchboards.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Electrical › Electrical Distribution System (service) › Switch
Issued 11 June 2014 Resolved
Properly mount Lane 8 & 10 Control Box on main deck, aft port side.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Electrical › Electrical Distribution System (service) › Junction Box
Issued 11 June 2014 Resolved
Properly mount wire into junction box at forward end of lane 7 on 2nd deck.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Electrical › Electrical Distribution System (service) › Junction Box
Issued 11 June 2014 Resolved
Ensure all conduit is properly connected to junction boxes between lanes.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 June 2014 Resolved
Properly mount the two panel boards between fr. 23 & 24, port side 2nd deck.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 June 2014 Resolved
Properly label all panel boards.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 11 June 2014 Resolved
Remove or properly install the shore power disconnect on the maindeck starboard side.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 June 2014 Resolved
Provide a blank in the L1 Panel in the starboard generator room.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 11 June 2014 Resolved
Remove the plastic drum in front of the heater in the storage room in the starboard generator room.
Action required: 705 - Other - as specified
Due 17 July 2014
Resolved 19 June 2014
Electrical › Electrical Distribution System (service) › Switchboard
Issued 4 June 2014 Resolved
Properly secure the front panels on the switchboard in the starboard generator room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2014
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 30 April 2014 Resolved
Properly label all motor controllers.
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 2 July 2014
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1-Routine Visual Inspections
Issued 9 April 2014 Resolved
As per the approved VGP the company did conduct the weekly checks
Due 27 April 2014
Resolved 2 July 2014
Construction/Loadline › Hull › Hull Plating
Issued 9 April 2014 Resolved
Insert P/S curtain 3rd window aft from bow
Due 9 May 2014
Resolved 14 April 2014
Resolution: Inserted 18x18
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 April 2014 Resolved
Secure J-box fr 38 Stbd side
Due 9 May 2014
Resolved 14 April 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 April 2014 Resolved
Replace overhead light fixture fr STBD
Due 9 May 2014
Resolved 14 April 2014
Electrical › Lighting (service) › Lighting Fixture
Issued 9 April 2014 Resolved
Secure light fixture STBD fr 7 1/2
Due 9 May 2014
Resolved 11 June 2014
Resolution: Light fixture on starboard side near frame 7 1/2 is properly secured.
Electrical › Electric Generation Source (service) › Generator
Issued 9 April 2014 Resolved
Clean STBD gen set windings, Install lagging, repair oil leak & Replace fire ext
Due 27 April 2014
Resolved 14 April 2014
Resolution: Cleaned space
Electrical › Lighting (service) › Lighting Fixture
Issued 9 April 2014 Resolved
Replace Guard on light in spill kit space
Due 27 April 2014
Resolved 14 April 2014
Electrical › Lighting (service) › Lighting Fixture
Issued 9 April 2014 Resolved
Repair exit light Port Gen Room
Due 27 April 2014
Resolved 14 April 2014
Electrical › Lighting (service) › Lighting Fixture
Issued 9 April 2014 Resolved
Secure Light Fixture Fr 37 port
Due 27 April 2014
Resolved 14 April 2014
Electrical › Lighting (service) › Lighting Fixture
Issued 9 April 2014 Resolved
Secure receptacle Fr 25 1/2 port side Deck 2
Due 27 April 2014
Resolved 14 April 2014
Lifesaving › Buoyant Apparatus › Serviceable
Issued 9 April 2014 Resolved
Replace life ring buoy Fwd bow
Due 27 April 2014
Resolved 14 April 2014
Construction/Loadline › Hull › Hull Plating
Issued 9 April 2014 Resolved
G/W crack in side shell Fr31 1/2 STBD side main deck
Due 9 May 2014
Resolved 14 April 2014
Deck/Cargo › Holds/Tanks › Ullage
Issued 9 April 2014 Resolved
Repair or Replace ladder to car deck upper on second deck
Due 27 April 2014
Resolved 14 April 2014
Construction/Loadline › Hull › Girder
Issued 27 August 2013 Resolved
Void 3 Center tank: Repair fractured weld in way of frame 15, port diagonal and transverse underdeck girder. Repair fracture in way of center line girder frame 17. Repair fracture in way of frame 15 starboard diagonal and transverse underdeck girder.
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 28 May 2014
Resolution: Repairs were made, and NDT testing was completed satisfactorily.
Construction/Loadline › Hull › Girder
Issued 27 August 2013 Resolved
Void # 3 Port: descale bottom and associated stiffeners to 3 inches above waterline.
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 27 August 2013
Construction/Loadline › Hull › Girder
Issued 27 August 2013 Resolved
Void # 4 Center: Repair fracture in way of frame 19 overhead centerline girder. Crop and renew the centerline vertical keel in way of frame 21-22 a minimum length of 20"x18"x6".
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 5 May 2014
Resolution: Repairs were made, and NDT testing was completed satisfactorily.
Construction/Loadline › Hull › Girder
Issued 27 August 2013 Resolved
Void # 6 Center: Repair fractured girder at bottom transverse in way of frame 28 port long bulkhead. Repair fractured weld in way of frame 30 centerline vertical keel.
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 23 May 2016
Construction/Loadline › Structures › Manhole
Issued 27 August 2013 Resolved
Void # 6 Port: Secure unstable ladder.
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 23 May 2016
Electrical › Lighting (service) › Conductor
Issued 12 April 2012 Resolved
Cover battery boxes located in port aux machinery space.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2012
Resolved 6 June 2012
Resolution: Provided digital photos.
Construction/Loadline › Hull › Stiffener
Issued 12 April 2012 Resolved
Cover battery boxes located in port aux machinery space.
Due 6 June 2012
Resolved 6 June 2012
Construction/Loadline › Hull › Bracket
Issued 12 April 2012 Resolved
Crop and renew vertical support beam, third deck, fr. 11, lane 4
Due 6 June 2012
Resolved 6 June 2012
Construction/Loadline › Hull › Bracket
Issued 12 April 2012 Resolved
Crop and renew vertical support beam, second deck, between fr. 5/7
Due 6 June 2012
Resolved 6 June 2012
Construction/Loadline › Hull › Bracket
Issued 12 April 2012 Resolved
Crop and renew side shell IWO fr. 34 window
Due 6 June 2012
Resolved 6 June 2012
Construction/Loadline › Hull › Bracket
Issued 12 April 2012 Resolved
Crop and renew vertical support beam, second deck, fr. 19/20, lane 5/7
Due 6 June 2012
Resolved 6 June 2012
Construction/Loadline › Hull › Weld
Issued 12 April 2012 Resolved
Crop and renew weld IWO trailer stand, first deck, 11B
Due 6 June 2012
Resolved 6 June 2012
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 April 2012 Resolved
Repair or replace EXIT light in port and stbd side aux machinery space.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2012
Resolved 6 June 2012
Resolution: Provided digital photos.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 8 April 2010 Resolved
Crop and renew the main vertical stanchion in way of FR. 38, Lane 7.
Action required: 705 - Other - as specified
Due 20 May 2010
Resolved 20 May 2010
Resolution: New stantion installed.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 8 April 2010 Resolved
Insert the main vertical stanchions in way of FR. 19, between lanes 5 and 7, and FR. 34 between lanes 5 and 7, on the Second Deck.
Action required: 705 - Other - as specified
Due 20 May 2010
Resolved 20 May 2010
Resolution: Statntions inserted.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 April 2010 Resolved
Reattach the junction box in way of FR. 25, port and starboard side, outboard at the fashion plate, and the light switch box in the port generator room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2010
Resolved 20 May 2010
Resolution: Secured.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 April 2010 Resolved
Renew the light fixture in way of FR. 37, lane 9, with one suitable for Class I, Div. 2 location.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2010
Resolved 20 May 2010
Resolution: Renewed with a proper light fixture.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 8 April 2010 Resolved
Correct the SOPEP to include the current local contact telephone numbers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 May 2010
Resolved 20 May 2010
Resolution: Pen and ink corrections.
Engineering › Fuel Oil Service System › Hose
Issued 8 April 2010 Resolved
Renew the deteriorated fuel oil hoses on the port and starboard generator prime movers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2010
Resolved 20 May 2010
Resolution: New proper type hose assemblies installed.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 8 April 2010 Resolved
Properly seal the electrical box in way of the fuel solenoid for the #2 generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2010
Resolved 20 May 2010
Resolution: Properly mounted.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 April 2010 Resolved
Provide proof of USCG or ABS plan approval for the recently installed lighting fixture spot lights, until such time as approved drawings are provided, the lighting system is to be secured when HAZMAT cargo is being loaded / unloaded / or on board the vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 May 2010
Resolved 19 August 2011
Resolution: ABS APPROVED ELECTRICAL SYSTEM.
Electrical › Lighting (service) › Outlet Box
Issued 9 April 2009 Resolved
The cover of the electrical box, frame 45, lane 6-8, is missing. Provide cover.
Action required: 705 - Other - as specified
Due 9 May 2009
Resolved 7 May 2009
Resolution: Cover replaced
Construction/Loadline › Hull › Stiffener
Issued 9 April 2009 Resolved
Crop and renew main vertical stanchion at frame 19 between lanes 5 and 7 to good metal.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 May 2009
Resolved 7 May 2009
Resolution: Area renewed
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 9 April 2009 Resolved
Ramp pin on loading ramp for lane 5 is wasted. Crop and renew pin on 3rd deck
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 May 2009
Resolved 7 May 2009
Resolution: Loading ramp was replaced
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 9 April 2009 Resolved
Ramp bracket on starboard outboard side of 3rd deck is wasted. Crop and renew
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 May 2009
Resolved 7 May 2009
Resolution: Ramp pin bracket was replaced
Deck/Cargo › Cargo Stowage › General
Issued 9 April 2009 Resolved
Starboard most outboard pulley/sheeve bracket on 3rd deck is wasted. Crop and renew.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 May 2009
Resolved 7 May 2009
Resolution: Pulley and bracket were replaced
Construction/Loadline › Hull › Stiffener
Issued 9 April 2009 Resolved
Crop and renew bottom of vertical stanchion at frame 50 between lanes 5-7 on 2nd deck
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 May 2009
Resolved 7 May 2009
Resolution: Area renewed
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 April 2009 Resolved
Main deck, frame 17, STARBOARD side hand rail is crack. Properly repair hand rail.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 May 2009
Resolved 7 May 2009
Resolution: Crack was welded
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 April 2009 Resolved
Exhaust piping is exposed on the 2nd deck car deck, PORT side. Provide protective lagging.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 May 2009
Resolved 7 May 2009
Resolution: Protective cage installed
Construction/Loadline › Hull › Stiffener
Issued 7 April 2009 Resolved
Support stanchions are fractured and/or wasted. Repair/replace the following on the MAIN DECK: - frame 14, lane 8-6 - frame 16, lane 8-6 - frame 16, lane 5-7 - frame 19, lane 5 - frame 33, lane 5-7 - frame 33, lane 5-7, diagonal - frame 35, lane 5-7, diagonal - frame 35, lane 1-3, diagonal - frame 46, lane 5-7 - frame 48, lane 5-7
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 May 2009
Resolved 7 May 2009
Resolution: Areas repaired with collars and new metal
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 7 April 2009 Resolved
the operating capability of the 1 and 2 ballast pump breaker panels and the STARBOARD side of the MAIN deck is in question due to wear. Demonstrate proper operation of the the panels and pumps.
Action required: 705 - Other - as specified
Due 9 May 2009
Resolved 7 May 2009
Resolution: Proper operation verified
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 April 2009 Resolved
There is a section of missing hand rail on the SECOND deck car deck, amidships near the ladder. Provide railing for the entire length.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 May 2009
Resolved 7 May 2009
Resolution: Handrail installed
Electrical › Electrical Distribution System (service) › Cable
Issued 7 April 2009 Resolved
The cable run and light on the MAIN deck, frame 25, lane 8-6 is broken. Repair the damaged electrical components.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 7 May 2009
Resolution: Cable run and junction boxes were renewed.
Electrical › Electric Generation Source (service) › Generator
Issued 7 April 2009 Resolved
Operation of both the PORT and STARBOARD generators could not be verified. Successfully demonstrate all operating functions including emergency shut-down PRIOR TO DEPARTURE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 9 May 2009
Resolved 10 April 2009
Resolution: The attending ABS inspector verified the proper operation of both generators.
Construction/Loadline › Hull › Stiffener
Issued 7 April 2009 Resolved
Support stanchions are fractured and/or wasted. Repair/replace the following on the SECOND DECK: - frame 50, lane 5-7 - frame 20, lane 5-7
Action required: 705 - Other - as specified
Due 9 May 2009
Resolved 7 May 2009
Resolution: Area repaired with collars and new metal
Construction/Loadline › Structures › Door
Issued 7 April 2009 Resolved
The watertight door to the bow deck on the SECOND deck FORWARD is wasted. provide and properly install new door. 5/7/09 timeline extended. Door is on order
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 January 2010
Resolved 14 January 2010
Resolution: WTD was properly replaced and tested
Documentation › Markings/Placards › Warning Signs
Issued 7 April 2009 Resolved
Remote emergency fuel shutoff valve on the tow bit deck is missing. Provide label that indicates on/off position.
Action required: 705 - Other - as specified
Due 9 May 2009
Resolved 7 May 2009
Resolution: Shut offs labeled
Construction/Loadline › Structures › Manhole
Issued 13 February 2009 Resolved
Replace all studs on manhole covers as needed throughout the vessels.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 12 March 2009
Resolution: New studs installed as needed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 February 2009 Resolved
Renew the bottom hand rail on the upper deck, fwd, port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 12 March 2009
Resolution: Hand rail repaired satisfactory.
Deck/Cargo › Cargo Stowage › General
Issued 13 February 2009 Resolved
Renew or replace all wasted D-rings on the upper deck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 12 March 2009
Resolution: Removed all wasted D-rings. All Sat.
Electrical › Electrical Distribution System (service) › Cable
Issued 13 February 2009 Resolved
Properly hardwire the batteries in the port generator room.
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 12 March 2009
Resolution: Battery charger and battery wiring renewed. All Sat.
Deck/Cargo › Cargo Stowage › General
Issued 30 October 2008 Resolved
Crop and renew deck plate on car decks in lanes 4 and 6 between frames 14 and 21 on second deck.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2008
Resolution: Installed new car decks. All Sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 October 2008 Resolved
Repair broken electrical conduit and enclose all wires on main deck between lanes 1 and 3.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2008
Resolution: Installed new conduit. All Sat.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 30 October 2008 Resolved
Repair broken light fixture and junction box (hot wire exposed) between frames 27 and 28 between lanes 1 and3.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2008
Resolution: New junction box installed. All Sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 June 2008 Resolved
Several wire hangers are wasted throughout the vessel. Properly hang all electrical wiring: On the main deck on the stbd side at frames 38-39, the overhead stbd side between frames 38-39, overhead port side from frames 34to 38. Second deck overhead at frame 37 lane 8, frames 25 to 26 port side shell, frames 19 to 21 lane 8 overhead, frames 2 and 5 transverse wire runs on port side of vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2008
Resolved 18 July 2008
Resolution: New hangers installed as needed. All Sat.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Crankcase
Issued 19 June 2008 Resolved
Port inboard generator has excessive oil leaks, clean up oil, troubleshoot and repair oil leak/leaks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2008
Resolved 18 July 2008
Resolution: Oil cleaned up on and around generator, ran engine no excessive leaks found. All Sat.
Construction/Loadline › Hull › Stiffener
Issued 19 June 2008 Resolved
Crop and renew vertical stanchions: Onthe main deck; at frame 20 between lanes 6&8, frame 37 between lanes 2&4.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2008
Resolved 18 July 2008
Resolution: Stanchions inserted. All Sat.
Construction/Loadline › Hull › Stiffener
Issued 19 June 2008 Resolved
Crop and renew diagonal and vertical stanchions on the second deck: at frame 33 between lanes 6 and 8, at frame 21 between frames 6 and 8.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2008
Resolved 18 July 2008
Resolution: Stanchions inserted. All Sat.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 June 2008 Resolved
Remove or properly reattach all loose safety/handrail cables throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2008
Resolved 18 July 2008
Resolution: All cables removed from vessel. All Sat.
Construction/Loadline › Structures › Deck Plating
Issued 19 June 2008 Resolved
Crop and renew wasted deck on car panel between frames 21 to 22 at lane 6.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2008
Resolved 18 July 2008
Resolution: Doublers installed as needed. All Sat.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 19 June 2008 Resolved
Replace wasted drain plug for fuel station containment on second deck bow.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2008
Resolved 18 July 2008
Resolution: New plug installled. All Sat.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 June 2008 Resolved
Third deck port side ladder needs new hand rail and safety chain.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2008
Resolved 18 July 2008
Resolution: Hand rail rewelded in place, new chain installed. All Sat.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 June 2008 Resolved
Repair hand rail on third deck forward centerline.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 July 2008
Resolved 18 July 2008
Resolution: Hand rail rewelded as needed. All Sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 June 2008 Resolved
Port nav light not working, troubleshoot and repair.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2008
Resolution: Rotation assembly was stuck, satisfactory repair made.
Construction/Loadline › Hull › Hull Plating
Issued 19 July 2007 Resolved
Repair cracks in the side curtain near windows on the port and stbd side to be completed at next dry dock.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 January 2011
Resolved 20 May 2010
Resolution: Side curtain fractures repaired.
Construction/Loadline › Hull › Stiffener
Issued 19 July 2007 Resolved
Crop and renew 2nd longitudinal stiffener at frame 46 to good metal on the main deck, port side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 16 August 2007
Resolution: Longitudinal stiffener replaced, picture of repair in vessel''s file - statement of repair included in vessel activity.
Construction/Loadline › Structures › Superstructure
Issued 19 July 2007 Resolved
Inspect all vertical and diagonal stanchions for cracks and wastage. Make repairs as needed, including those identified by marine inspectors.
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 16 August 2007
Resolution: All repairs made to those stanchions identified by USCG MI''s, pictures of repairs included in vessel''s file - statement of repairs attached to activity.
Construction/Loadline › Hull › Stiffener
Issued 19 July 2007 Resolved
Replace missing longitudinal stiffeners between frames 6 and 7 on the port side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 16 August 2007
Resolution: Missing longitudinal replaced, pictures of repair placed in vessel''s file - statement of repairs attached to activity.
Engineering › Diesel Engine (auxiliary) › Block
Issued 19 July 2007 Resolved
Remove all oil and clean generator on the port side, investigate potential oil leak or exhaust leak. Demonstrate proper operation of engine.
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 2 August 2007
Resolution: Engine was cleaned, ran engine did not find any excessive leaks. All Sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 July 2007 Resolved
Properly mount exit sign and blue light in port side generator room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 16 August 2007
Resolution: New exit signs placed in both port and stbd generator rooms, blue light removed and system disabled - statement of completed repairs attached to activity.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 19 July 2007 Resolved
Investigate potential ground on phases A&B in the stbd generator room distribution panel.
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 2 August 2007
Resolution: Ground cleared, all sat.
Construction/Loadline › Structures › Superstructure
Issued 19 July 2007 Resolved
Crop and renew to good metal the overhead long structure member at frame 38 on the main deck in lane 7&5.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 16 August 2007
Resolution: All repairs made, pictures of repairs placed in vessel''s file - statement of repairs attached to activity.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 July 2007 Resolved
Replace cover on the J-Box at frame 26 on the 2nd deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 2 August 2007
Resolution: New cover installed, all sat.
Construction/Loadline › Structures › Superstructure
Issued 19 July 2007 Resolved
Crop and renew gusset on the vertical support at frame 37 on the 2nd deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 2 August 2007
Resolution: Gusset was renew as required, all sat.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 19 July 2007 Resolved
Replace safety cables on 2nd and 3rd car deck levels and ensure all safety chains are placed around ladders.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 16 August 2007
Resolution: New safety cables run along all car decks and safety chains placed around all ladders - statement of repairs attached to activity.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 July 2007 Resolved
Secure J-Box in the overhead at frame 26 in lane 7.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 2 August 2007
Resolution: Junction box properly secured, all sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 July 2007 Resolved
Repair or replace light fixture and bracket on the 2nd deck at frame 33 in lane 7.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 2 August 2007
Resolution: New light fixture installed. All Sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 July 2007 Resolved
Replace light fixture on the car deck on the 2nd deck at frame 18.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 2 August 2007
Resolution: New light fixture installed, all sat.
Electrical › Electrical Distribution System (service) › Cable
Issued 19 July 2007 Resolved
Re-secure wiring in the over head at frames 36and 35 in lane 7
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 16 August 2007
Resolution: All wiring secured - statement of repairs attached to activity.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 July 2007 Resolved
Resecure the cover over the wiring on each generator and the l3 lighting panel in the stbd generator room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 2 August 2007
Resolution: Cover properly secured. all sat.
Engineering › Compressed Air System (start air) › Valve
Issued 19 July 2007 Resolved
Demonstrate proper operation of the relief valves on both air receiver.
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 2 August 2007
Resolution: Relief valves tested, all sat.
Construction/Loadline › Structures › Superstructure
Issued 19 July 2007 Resolved
Repair or replace stanchions: main deck at frames 15 in lane 3, frame 17 in lane 4, frame 31 in lanes 5 & 7, frame 32, frame 39 in lanes 5 & 7. 2nd deck: frame 50 in lane 1 & 4--6 & 8, frame 17 in lanes 6 & 8.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2007
Resolution: All stanchions were repaired.
Construction/Loadline › Hull › Hull Plating
Issued 14 April 2006 Resolved
Crop and renew insert IWO lane 4-6 curbing from frame 35-36. Contact a Marine Inspector prior to final weld out to check fit up.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 28 April 2006
Construction/Loadline › Hull › Hull Plating
Issued 14 April 2006 Resolved
Insert car lane No 1 at Frame 41with a minimum 18"x 18".
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 28 April 2006
Construction/Loadline › Hull › Side Shell
Issued 24 January 2006 Resolved
Numerous fractures through out vessel . See narrative for locations, resolutions.
Condition: Design Flaw
Due 31 March 2006
Resolved 14 April 2006
Construction/Loadline › Hull › Stiffener
Issued 25 May 2005 Resolved
Main deck, crop and renew diagonal support pipes at the following locations: FR 36 Lane 8-6, FR 50 LN 5-7, FR 18 LN 8-6, FR 18 LN 4-2, FR 32 LN 5-7.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 June 2005
Resolved 8 July 2005
Construction/Loadline › Hull › Stiffener
Issued 25 May 2005 Resolved
Main deck, crop and renew vertical support pipes at the following locations: FR 49 Lane 5-7, FR 49 LN 2-4, FR 49 LN 1-3.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 June 2005
Resolved 8 July 2005
Construction/Loadline › Hull › Stiffener
Issued 25 May 2005 Resolved
Second deck, crop and renew diagonal support pipes at the following locations: FR 17 Lane 5-7, FR 19 LN 5-7, FR 34 LN 1-3,. In addition weld top of vertical support at FR 16-LN 1-3.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 June 2005
Resolved 8 July 2005
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 25 May 2005 Resolved
Make permanent repairs to the fuel oil storage tank Vent pipe located on the foscle. Repairs to be completed at next dry docking.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 14 April 2006
Construction/Loadline › Hull › Side Shell
Issued 15 September 2004 Resolved
Make permanent repair in lieu of temporary repair (doubler) to vertical crack in the forward rake side shell. Renew damaged internals in way of inset between transverse frame 2 and 3 center forward rake.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 January 2005
Resolved 12 January 2005
Resolution: Witnessed repair [name withheld]
Construction/Loadline › Hull › Side Shell
Issued 15 September 2004 Resolved
Make permanent repair to the side shell inset and damaged bulkhead (forward rake) portside approximately 11 feet above the water line. This requirement to be completed to the satisfaction of a US Coast Guard Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 January 2005
Resolved 12 January 2005
Resolution: Witnessed repair [name withheld]
Engineering
Issued 24 January 2001 Resolved
Do not operate #2 generator until oil leak is located and corrected.
Condition: Unknown
Due 24 January 2001
Resolved 24 January 2001
Engineering
Issued 24 January 2001 Resolved
Prove proper operation of overspeed shutdown on #2 generator.
Condition: Unknown
Due 24 January 2001
Resolved 24 January 2001
Unknown
Issued 24 January 2001 Resolved
Repaint name and hailing port on the stern.
Condition: Unknown
Due 24 January 2001
Resolved 24 January 2001
Electrical
Issued 24 January 2001 Resolved
Install missing covers on overhead lights in both port and stbd machinery space.
Condition: Unknown
Due 24 January 2001
Resolved 24 January 2001
Accommodation/Occupational Safety
Issued 24 January 2001 Resolved
Make repairs on broken railings on the bow and top deck.
Condition: Unknown
Due 24 January 2001
Resolved 24 January 2001
Construction/Loadline
Issued 24 January 2001 Resolved
Crop and renew to good metal, second deck support stanchion iwo frame 48 above port longitudinal bulkhead.
Condition: Unknown
Due 24 January 2001
Resolved 24 January 2001
Construction/Loadline
Issued 21 January 1999 Resolved
CROP AND RENEW UPSET SECTION OF MAIN DECK LOCATED AT PORT SIDESHELL BETWEENFRAMES 53 & 54.
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Electrical
Issued 21 January 1999 Resolved
LABEL CIRCUITS ON ELECTRICAL PANEL BOX INSIDE COVERS.
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Electrical
Issued 21 January 1999 Resolved
SEAL UNUSED ELECTRICAL PANEL STUFFING TUBES 2ND DECK PORT SIDE MIDBODY AREA.
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Lifesaving
Issued 21 January 1999 Resolved
REPAIR BROKEN AND BENT UPPER DECK PORT FORWARD LADDER HAND RAIL.
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Construction/Loadline
Issued 21 January 1999 Resolved
CROP AND RENEW DISTORTED LOWER BRACKET AND FRACTURED VERTICAL FRAMES LOCATED AT AFT STARBOARD CORNER OF VESSEL IN WAY OF #18 STARBOARD RAKE.
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Electrical
Issued 21 January 1999 Resolved
RENEW DETERIORATED PUSH BUTTONS ON MAIN DECK FRESH AND SEA WATER BALLAST CONTROLLER PANELS.
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Lifesaving
Issued 21 January 1999 Resolved
REPLACE SIX AFT SECTIONS OF UPPER DECK RAIL IN WAY OF STARBOARD SIDE.
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Construction/Loadline
Issued 21 January 1999 Resolved
CROP AND RENEW UPSET SECTION OF OUTBOARD VERTICAL DEEP WEB FRAME IN WAY OF #10 PORT TANK.
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Electrical
Issued 21 January 1999 Resolved
REMOVE DEAD END WIRING LOCATED ON 2ND DECK STERN OVERHEAD AND PORT SIDE FRAME 15.
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Electrical
Issued 21 January 1999 Resolved
REPLACE MISSING LABELS ON MAIN DECK ELECTRICAL CONTROLLERS MAIN DECK AFT STARBOARD SIDE AND 2ND DECK AFT STARBOARD SIDE CONTROLLERS.
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Electrical
Issued 19 February 1998 Resolved
REPAIR/RENEW RESET BUTTON ON RAMP CONTROL BOX, MAIN DECK, PORT/QUARTER.
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Electrical
Issued 19 February 1998 Resolved
INSTALL BLANKS IN OPENINGS IN BREAKER PANEL FOR LIGHTING PANEL L1.
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Construction/Loadline
Issued 19 February 1998 Resolved
REPAIR FRACTURE AT FRAME 34, STBD SIDE AT SIDE SHELL OPENING ABOVE MAIN DECK.
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Electrical
Issued 19 February 1998 Resolved
RENEW CONDUIT, STBD MAIN DECK, BETWEEN FRAMES 17 AND 18.
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Documentation
Issued 19 February 1998 Resolved
PROVIDE COD REFLECTING NEW OWNER NAME._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 May 1998
Resolved 9 March 1998
Electrical
Issued 19 February 1998 Resolved
RENEW ALL DETERIORATED KICKTUBES FOR RAMP WINCHES ON 3RD DECK.
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Engineering
Issued 19 February 1998 Resolved
PROVE OPERATION OF OVERSPEED TRIP ON #1 SSG.
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Electrical
Issued 19 February 1998 Resolved
RENEW BREAKER BOX, MAIN DECK, PORT QUARTER.
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Electrical
Issued 19 February 1998 Resolved
RENEW CONSUIT, PORT SIDE MAIN DECK, BETWEEN FRAMES 34 AND 35.
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Documentation
Issued 21 January 1997 Resolved
PROVIDE CURRENT LOADLINE CERTIFICATE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 February 1997
Resolved 3 March 1997
Construction/Loadline
Issued 31 January 1996 Resolved
IN #4 PORT VOID: D) crop/renew sidelongs in 2nd frame from aft at 10,12, 14,16 foot levels; fair or insert sideshell as necessary._x001C_ E) crop/renew sidelongs in forward frame bay at 10,12,14 foot levels; fair or insert sideshell as necessary.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
In #1 PORT VOID:_x001C_ Vee & weld fracture on number 2 inboard vertical channel to lower side longitudinal.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
IN #7 STBD VOID:_x001C_ Reweld 2nd from top sidelong to side shell plating in way of Bay 3.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
IN #3 PORT VOID: A) in forward frame bay outboard, crop/renew corner gussets at 6,10,12 fooot levels; crop/renew sidelongs at 10,12,14 foot levels, fair or insert sideshell as necessary. B) at forward sideshell vertical renew truss bracket.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
IN #4 PORT VOID: A) renew truss brackets at #1,2,3 vertical sideshell stiffners. B) crop/renew outboard corner brackets at 6 & 8 foot levels at aft bulkhead. C) crop/renew sidelongs in aft frame bay, 6,8,10 foot levels; fair or insert sideshell as necessary.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
In #1 PORT VOID:_x001C_ Vee & weld fractured welds on 4th from bottom side long in Bay 2.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
Make salt water ballast and fresh water heeling tanks available for internal examination.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
IN #2 STBD VOID: at frame 12 crop/renew sidelong at 14 foot level, fair orinsert sideshell as necessary.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
IN #3 STBD VOID: fractured weld at inboard vertical & lower sidelong, frame 16.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
IN #2 PORT VOID: C) center frame bottom transverse & sideshell vertical tripped, crop/renew lower 11 feet of vertical & outboard 5 feet of bottom transverse, renew truss bracket. D) bulkhead 14 outboard, renew corner gussets at 6,8,10 foot levels.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
IN #2 CENTER VOID: fractured weld in bracket at after truss diagonal and CVK, grind & reweld.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
IN #1 CENTER VOID: fracture at joint of forward bottom transverse & CVK, port side. grind & reweld.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
IN #2 PORT VOID: A) forward bulkhead outboard creased at sideshell betweensidelongs at 6 & 12 foot levels; crop/insert bulkhead, sideshell & sidelongs. B) forward sideshell vertical tripped, crop/renew @ lower 10 feet; renew truss bracket.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
IN #1 STBD VOID: at aft bulkhead outboard renew lower 2 corner gussets; fair or insert sidelong connection at 10 foot level.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
IN #3 CENTER VOID: A) bulkhead #18 & CVK, fractured weld in truss bracketto truss connection._x001C_ B) Frame #17 & CVK, fractured weld in truss bracket & truss connection.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
IN #7 STBD VOID: frame #31, inboard vertical & lower sidelong, fractured weld.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
IN #8 STBD VOID: fractured welds at inboard sidelong (lower) & verticals at frames 35,36,37.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
In #1 PORT VOID:_x001C_ Crop & renew aft outboard bulkhead in way of 4 lower side frames & 2 buckled brackets.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
In #1 PORT VOID: _x001C_ renew crushed section of forward side vertical channel at lower 3 side frames in bay 2.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
IN #3 PORT VOID: C) center bottom transverse & sideshell vertical tripped;crop/renew to good metal, renew truss bracket. D) aft transverse & sideshell vertical tripped, crop/renew to good metal, renew truss bracket. E) aft bulkhead outboard, renew corner gussets at 6,8,10 foot levels.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996 Resolved
IN #3 PORT VOID: F) aft frame bay- crop/renew sidelongs at 8,10,12,14 footlevels, fair or insert sideshell as necessary.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Electrical
Issued 1 February 1995 Resolved
Provide proper covers and securing devices for all electrical connections and wires for three installed generators.
Condition: Unknown
Due 1 February 1995
Resolved 1 February 1995
Electrical
Issued 1 February 1995 Resolved
Provide proper securing devices for installed wire runs throughout vessel.
Condition: Unknown
Due 1 February 1995
Resolved 1 February 1995
Electrical
Issued 1 February 1995 Resolved
Prove proper operation of installed lighting throughout vessel.
Condition: Unknown
Due 1 February 1995
Resolved 1 February 1995
Construction/Loadline
Issued 16 March 1994 Resolved
In 1S repair following: A)fracture in way of #1 sidelong at forward deep web inboard. B)crop/insert in way of #2,3 sidelongs at forward vertical stiffner outboard. C)crop/insert in way of #2 sidelong at center vertical stiffner outboard.
Condition: Unknown
Due 31 March 1994
Resolved 30 March 1994
Construction/Loadline
Issued 16 March 1994 Resolved
In 2S repair fracture in way of #3 sidelong at forward deep web outboard.
Condition: Unknown
Due 31 March 1994
Resolved 18 March 1994
Construction/Loadline
Issued 16 March 1994 Resolved
Prior to departing Jacksonville, make temporary repairs to CVK fracture in 10C ballast tank to the satisfaction of attending Marine Inspector.
Condition: Unknown
Due 17 March 1994
Resolved 18 March 1994
Construction/Loadline
Issued 16 March 1994 Resolved
Make permanant repair to CVK fracture in 10C ballast tank in a manner acceptable to Class Society. USCG to examine repair & complete class 1 fracture report.
Condition: Unknown
Due 31 March 1994
Resolved 18 March 1994
Construction/Loadline
Issued 16 March 1994 Resolved
Make fresh water ballast tanks 9P & 9S available for internal examination.
Condition: Unknown
Due 31 March 1994
Resolved 22 March 1994
Construction/Loadline
Issued 16 March 1994 Resolved
In 3P make following repair: A)crop/renew 5 feet of aft transverse deep weboutbd. B)Crop/insert in way of #2,3 sidelongs at aft vertical stiffner. C) crop/insert in way of #2,3 sidelongs at center vertical stiffner. D)crop/ insert in way of #6,7 sidelongs at center vertical stiffner.
Condition: Unknown
Due 31 March 1994
Resolved 30 March 1994
Construction/Loadline
Issued 16 March 1994 Resolved
In 6S repair fracture at #1 inboard sidelong, center deep web.
Condition: Unknown
Due 31 March 1994
Resolved 18 March 1994
Construction/Loadline
Issued 16 March 1994 Resolved
In 5S repair fractures in way of #3,4 sidelongs at forward deep web outboard.
Condition: Unknown
Due 31 March 1994
Resolved 18 March 1994
Construction/Loadline
Issued 3 March 1993 Resolved
REPAIR PORT AFT CORNER WRAPPER AND ASSOCIATED DAMAGED INTERNAL MEMBERS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Engineering
Issued 3 March 1993 Resolved
REPAIR AS NEEDED DIESEL ENGINE EXHAUST STACKS ON DECK TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Accommodation/Occupational Safety
Issued 3 March 1993 Resolved
REPAIR DAMAGED GUARD RAIL ON PORT AFT QUARTER TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Accommodation/Occupational Safety
Issued 3 March 1993 Resolved
REPAIR DAMAGED GUARD RAIL ON PORT FWD DECK TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Lifesaving
Issued 18 February 1993 Resolved
prove proper operation of relief valve on air receiver, port engineroom.
Condition: Unknown
Due 18 February 1993
Resolved 18 February 1993
Accommodation/Occupational Safety
Issued 18 February 1993 Resolved
Make permanant repair to upper hand rail, upper deck port side.
Condition: Unknown
Due 18 February 1993
Resolved 18 February 1993
Deck/Cargo
Issued 18 February 1993 Resolved
Make permanant repair to damaged motor controller & stancion, upper deck port side aft.
Condition: Unknown
Due 18 February 1993
Resolved 18 February 1993
Electrical
Issued 18 February 1993 Resolved
Prove overspeed trip on port outboard generator.
Condition: Unknown
Due 18 February 1993
Resolved 18 February 1993
Engineering
Issued 4 February 1992 Resolved
PROVE PROPER OPERATION OF #2 & 3 S/S GENERATOR ENGINE SAFETY ALARMS AND SHUTDOWNS.
Condition: Unknown
Due 4 March 1992
Resolved 5 March 1992
Accommodation/Occupational Safety
Issued 4 February 1992 Resolved
PROPERLY MARK REMOTE MANUAL GENERATOR FUEL OIL SHUTDOWN HANDLES.
Condition: Unknown
Due 4 March 1992
Resolved 5 March 1992
Construction/Loadline
Issued 21 July 1989 Resolved
WELDS IN THE WIND AND WATER AREA TO BE REINSPECTED.
Condition: Unknown
Due 21 July 1989
Resolved 21 July 1989

Casualty record · 8

15 September 2004Routine · role: Involved in a Marine Casualty · activity 2241804
16 April 2008Routine · role: Involved in a Marine Casualty · activity 3192321
8 January 2009Routine · role: Involved in a Marine Casualty · activity 3411823
22 January 2010Routine · role: Transiting Vicinity of Primary Subject · activity 3668227
24 February 2013Significant Marine Casualty · role: Transiting Vicinity of Primary Subject · serious marine incident, as classified · 1 dead · activity 4541256
18 November 2016Routine · role: Involved in a Marine Casualty · activity 6069344
10 April 2018Routine · role: Subject to Coast Guard Operational Control · activity 6392316
11 October 2021Routine · role: Involved in a Marine Casualty · activity 7336352
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.