Documentation record
Registered dimensions (L × B × D)137.6 ft × 30.0 ft × 12.0 ft
Registered tonnagegross 98 / net 68
ITC dimensions (L × B × D)137.6 ft × 30.0 ft × 12.0 ft
ITC tonnagegross 309 / net 92
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1994
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portERATH, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 19 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it309 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
92 - Convention (Subpart B), Net Ton
68 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
13 February 2026
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8305104
4 February 2026
Administrative Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8299043
17 June 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8160634
12 June 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7934280
3 April 2024
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7883184
4 April 2023
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7662378
24 June 2022
Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7489015
23 June 2022
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7485919
7 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7407033
25 June 2021
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7235898
27 February 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6916696
20 February 2020
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6912338
27 March 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6652176
11 March 2019
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6640535
3 March 2019
Type not recorded
No type recorded · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6638183
19 March 2018
Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6374527
22 May 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6152399
22 March 2016
Internal Structural Exam · Annual Inspection · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5839189
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 12 June 2024
Resolved
A penetration in a watertight bulkhead must be made watertight. The vessel had numerous watertight bulkhead penetrations that were not watertight, port side of centerline in the engine room, between engine room and laundry room
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 27 June 2024
Resolved 12 June 2024
Resolution: Watertight firestop sealant used to fill through hull penetrations.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 June 2024
Resolved
Each life float and buoyant apparatus must be secured to the vessel by a painter and a float-free link that must be certified to meet 46 CFR 160.073. Float-free link tag was missing.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 27 June 2024
Resolved 12 June 2024
Resolution: Replaced float-free link that came with manufacturer's tag.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 June 2024
Resolved
Each ring life buoy must be of an approved type, constructed in accordance with 46 CFR 160.050. Ring life buoys shall be free from any defects materially affecting their serviceability. Vessel had two ring life buoys which had suffered damage to their water port resulting in a breach of integrity.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 June 2024
Resolved 12 June 2024
Resolution: Replaced faulty lifering buoys.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 12 June 2024
Resolved
Abandon ship, man overboard, and fire fighting drills shall be documented to include the date of the drill and training and the general description of the drill scenario and training topics. Required information didn't include required details.
Action required: 10 - Deficiency Rectified
Due 26 June 2024
Resolved 12 June 2024
Resolution: Master and Chief Mate acknowledge requirement and will begin filling out correct drill entries.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 June 2024
Resolved
Electrical equipment on a vessel must be installed so that it protects passengers crew, other persons, and the vessel from electrical hazards including fire. Vessel had several improper terminations for electrical wires under the operating station.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 June 2024
Resolved 12 June 2024
Resolution: Company electrician came onboard and retrieved unused wires and secured terminals of permanent wires.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 4 April 2023
Resolved
Irrespective of build date a vessel that operates on a coastwise or oceans route must have an interconnected fire detection system in compliance with 46CFR181.450. Vessel is not equipped with interconnected fire detection system in all required spaces.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2023
Resolved 13 February 2026
Resolution: MI observed interconnected fire detection panel operate as designed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 June 2022
Resolved
Flexible nonmetallic hose may be used fuel oil systems, subject to the following requirements: protected from mechanical damage. Port generator fuel return hose had chaffed on engine bed plate damaging inner core of hose. 46 CFR 182.720(e)(3)(ii)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2022
Resolution: Hose was replaced. Crew identified hose as a lube oil drain line versus a fuel line.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 23 June 2022
Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. One of the starboard rudder post vertical support welds were cracked. 46 CFR182.610(a)(1)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2022
Resolution: Weld was repaired.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 March 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel utilized a 2014 dated chart that contained only one correction which was dated in 2014. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2019
Resolution: New charts were provided and will be kept up to date.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 27 March 2019
Resolved
The master of the vessel shall ensure that each EPIRB be tested and documented that it was tested monthly. Vessel used a checklist that verified only registration date and battery date were satisfactory. No EPIRB tests were logged. 46 CFR 185.728(a) and 46 CFR 185.728(c).
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 March 2019
Resolution: Vessel modified onboard checklist to include testing of EPIRB.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 27 March 2019
Resolved
When a deck scuttle serves as a means of escape, it must be fitted with a quick acting release. Engine room escape scuttle had a portion of the hand release broken off. 46 CFR 177.500 (L)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2019
Resolution: Deck emergency escape handle was repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 March 2019
Resolved
Each life jacket carried on a vessel on oceans route must have an approved life jacket light. 06 life jackets lights were either dim or did not operate. 46 CFR 180.75(a)
Action required: 10 - Deficiency Rectified
Resolved 27 March 2019
Resolution: Vessel replaced batteries in all deficient lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 March 2019
Resolved
Each life jacket must be approved in accordance with 46 CFR Subchapter Q. 02 life jacket was found with a broken clip. 46 CFR 180.71(a).
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 March 2019
Resolution: Vessel had 2 additional lifejackets, of which these two were removed from the vessel and cut up.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2019
Resolved
Nonmetallic hose may be used for wet exhaust systems provided it is double clamped where practicable. The #2 main engine wet exhaust hose was not double clamped. 46 CFR 182.430(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2019
Resolved 2 April 2019
Resolution: Engine exhaust wet piping was double clamped.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 27 March 2019
Resolved
An exposed hazard must be properly protected by a cover, guard, or rail. The starboard engine room blower motor and generator room blower motor were missing guards. 46 CFR 177.960
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2019
Resolved 2 April 2019
Resolution: Wasted covers and rotating cooling fan were removed after consulting 3rd party electrical motor technician. Blower motors used in this application do not require cooling fans.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 March 2019
Resolved
Alcohol testing must be conducted on each individual directly involved in a serious marine incident within 2 hours of when it occurred. Alcohol testing equipment was not on board to allow vessel to meet 2 hour time requirement.46 CFR 4.06(a)(1)(i)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2019
Resolution: Alcohol test strips were provided.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 March 2019
Resolved
Vessel must be provided with main steering gear that is of adequate strength. Port and starboard rudder post supports were found with several weld fractures requiring repair.
46 CFR 182.610(a)(1)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2019
Resolution: Steering system weld repairs were completed.
Lifesaving › Lifefloat › Platform
Issued 22 March 2016
Resolved
Spacers missing between stacked lifefloats.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 1 April 2016
Resolution: Spacers installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 March 2016
Resolved
Water light not labeled with vessels name.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 1 April 2016
Resolution: Water light was stenciled with vessels name.
Communications › Radio Communications › VHF Radiotelephone
Issued 22 March 2016
Resolved
DSC was not installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 1 April 2016
Resolution: 3rd party Marine Electronics Tech. installed DSC capable VHF radio, wired to GPS position input source.
Lifesaving › Hand Flares › Not on Board
Issued 22 March 2016
Resolved
Missing one required hand flare.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 1 April 2016
Resolution: Vessel owner purchased new hand flare and installed aboard vessel.