Records from 1994 to 2026. Most recent: inspection, 13 February 2026.
Inspection history · 40
13 February 2026
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8305104
4 February 2026
Administrative Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8299043
17 June 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8160634
12 June 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7934280
3 April 2024
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7883184
4 April 2023
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7662378
24 June 2022
Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7489015
23 June 2022
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7485919
7 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7407033
25 June 2021
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7235898
27 February 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6916696
20 February 2020
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6912338
27 March 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6652176
11 March 2019
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6640535
3 March 2019
Type not recorded
No type recorded · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6638183
19 March 2018
Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6374527
22 May 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6152399
22 March 2016
Internal Structural Exam · Annual Inspection · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5839189
12 March 2014
Administrative Inspection · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4814918
5 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4202158
22 March 2010
Hull Examination · Administrative Inspection · Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3700447
1 August 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3285920
7 May 2008
Administrative Inspection · Ballast Water Examination · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3200958
29 June 2007
Ballast Water Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2977709
19 June 2006
Examination of Repairs · Ballast Water Examination · Hull Examination · Re-Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2680732
5 July 2005
Ballast Water Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2415508
11 November 2004
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 2242429
9 July 2004
Examination of Repairs · Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2139392
19 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978231
24 June 2003
COI Inspection · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1825759
20 June 2002
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1639367
21 June 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401501
15 June 2000
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427845
14 June 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386524
17 June 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436092
14 July 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438620
17 July 1996
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367815
31 October 1995
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1398386
25 September 1995
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1363375
28 September 1994
COI Inspection · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466905
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 12 June 2024
Resolved
A penetration in a watertight bulkhead must be made watertight. The vessel had numerous watertight bulkhead penetrations that were not watertight, port side of centerline in the engine room, between engine room and laundry room
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 27 June 2024
Resolved 12 June 2024
Resolution: Watertight firestop sealant used to fill through hull penetrations.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 June 2024
Resolved
Each life float and buoyant apparatus must be secured to the vessel by a painter and a float-free link that must be certified to meet 46 CFR 160.073. Float-free link tag was missing.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 27 June 2024
Resolved 12 June 2024
Resolution: Replaced float-free link that came with manufacturer's tag.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 June 2024
Resolved
Each ring life buoy must be of an approved type, constructed in accordance with 46 CFR 160.050. Ring life buoys shall be free from any defects materially affecting their serviceability. Vessel had two ring life buoys which had suffered damage to their water port resulting in a breach of integrity.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 June 2024
Resolved 12 June 2024
Resolution: Replaced faulty lifering buoys.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 12 June 2024
Resolved
Abandon ship, man overboard, and fire fighting drills shall be documented to include the date of the drill and training and the general description of the drill scenario and training topics. Required information didn't include required details.
Action required: 10 - Deficiency Rectified
Due 26 June 2024
Resolved 12 June 2024
Resolution: Master and Chief Mate acknowledge requirement and will begin filling out correct drill entries.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 June 2024
Resolved
Electrical equipment on a vessel must be installed so that it protects passengers crew, other persons, and the vessel from electrical hazards including fire. Vessel had several improper terminations for electrical wires under the operating station.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 June 2024
Resolved 12 June 2024
Resolution: Company electrician came onboard and retrieved unused wires and secured terminals of permanent wires.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 4 April 2023
Resolved
Irrespective of build date a vessel that operates on a coastwise or oceans route must have an interconnected fire detection system in compliance with 46CFR181.450. Vessel is not equipped with interconnected fire detection system in all required spaces.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2023
Resolved 13 February 2026
Resolution: MI observed interconnected fire detection panel operate as designed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 June 2022
Resolved
Flexible nonmetallic hose may be used fuel oil systems, subject to the following requirements: protected from mechanical damage. Port generator fuel return hose had chaffed on engine bed plate damaging inner core of hose. 46 CFR 182.720(e)(3)(ii)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2022
Resolution: Hose was replaced. Crew identified hose as a lube oil drain line versus a fuel line.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 23 June 2022
Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. One of the starboard rudder post vertical support welds were cracked. 46 CFR182.610(a)(1)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2022
Resolution: Weld was repaired.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 March 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel utilized a 2014 dated chart that contained only one correction which was dated in 2014. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2019
Resolution: New charts were provided and will be kept up to date.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 27 March 2019
Resolved
The master of the vessel shall ensure that each EPIRB be tested and documented that it was tested monthly. Vessel used a checklist that verified only registration date and battery date were satisfactory. No EPIRB tests were logged. 46 CFR 185.728(a) and 46 CFR 185.728(c).
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 March 2019
Resolution: Vessel modified onboard checklist to include testing of EPIRB.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 27 March 2019
Resolved
When a deck scuttle serves as a means of escape, it must be fitted with a quick acting release. Engine room escape scuttle had a portion of the hand release broken off. 46 CFR 177.500 (L)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2019
Resolution: Deck emergency escape handle was repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 March 2019
Resolved
Each life jacket carried on a vessel on oceans route must have an approved life jacket light. 06 life jackets lights were either dim or did not operate. 46 CFR 180.75(a)
Action required: 10 - Deficiency Rectified
Resolved 27 March 2019
Resolution: Vessel replaced batteries in all deficient lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 March 2019
Resolved
Each life jacket must be approved in accordance with 46 CFR Subchapter Q. 02 life jacket was found with a broken clip. 46 CFR 180.71(a).
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 March 2019
Resolution: Vessel had 2 additional lifejackets, of which these two were removed from the vessel and cut up.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2019
Resolved
Nonmetallic hose may be used for wet exhaust systems provided it is double clamped where practicable. The #2 main engine wet exhaust hose was not double clamped. 46 CFR 182.430(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2019
Resolved 2 April 2019
Resolution: Engine exhaust wet piping was double clamped.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 27 March 2019
Resolved
An exposed hazard must be properly protected by a cover, guard, or rail. The starboard engine room blower motor and generator room blower motor were missing guards. 46 CFR 177.960
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2019
Resolved 2 April 2019
Resolution: Wasted covers and rotating cooling fan were removed after consulting 3rd party electrical motor technician. Blower motors used in this application do not require cooling fans.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 March 2019
Resolved
Alcohol testing must be conducted on each individual directly involved in a serious marine incident within 2 hours of when it occurred. Alcohol testing equipment was not on board to allow vessel to meet 2 hour time requirement.46 CFR 4.06(a)(1)(i)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2019
Resolution: Alcohol test strips were provided.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 March 2019
Resolved
Vessel must be provided with main steering gear that is of adequate strength. Port and starboard rudder post supports were found with several weld fractures requiring repair.
46 CFR 182.610(a)(1)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2019
Resolution: Steering system weld repairs were completed.
Lifesaving › Lifefloat › Platform
Issued 22 March 2016
Resolved
Spacers missing between stacked lifefloats.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 1 April 2016
Resolution: Spacers installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 March 2016
Resolved
Water light not labeled with vessels name.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 1 April 2016
Resolution: Water light was stenciled with vessels name.
Communications › Radio Communications › VHF Radiotelephone
Issued 22 March 2016
Resolved
DSC was not installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 1 April 2016
Resolution: 3rd party Marine Electronics Tech. installed DSC capable VHF radio, wired to GPS position input source.
Lifesaving › Hand Flares › Not on Board
Issued 22 March 2016
Resolved
Missing one required hand flare.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 1 April 2016
Resolution: Vessel owner purchased new hand flare and installed aboard vessel.
Navigation
Issued 25 September 1995
Resolved
PROVIDE COMPASS DEVIATION TABLE FOR COMPASS.
Condition: Unknown
Due 25 October 1995
Resolved 25 October 1995
Construction/Loadline
Issued 25 September 1995
Resolved
COMPLETE CONTINUOUS WELDS ON BOTH PORT AND STARBOARD AFT BITTS IN STEERING COMPARTMENT.
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Engineering
Issued 25 September 1995
Resolved
PROVE PROPER OPERATION OF MAIN ENGINE(S) ALARMS AND SHUTDOWNS. PROVIDE DOCUMENTATION FROM MANUFACTURER STATING COMPLIANCE WITH REGULATIONS.
Condition: Unknown
Due 24 October 1995
Resolved 30 November 1995