Records from 1997 to 2026. Most recent: inspection, 8 April 2026.
Inspection history · 51
8 April 2026
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8313563
30 March 2026
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8313559
27 February 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8081558
16 October 2024
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8019658
14 March 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7878933
8 March 2024
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7876045
14 August 2023
Damage Survey
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7768782
13 August 2023
Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7769298
17 May 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7690799
1 June 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7465179
8 March 2022
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7407802
21 December 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7371288
14 October 2021
In-Service Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7332381
29 April 2021
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7185333
17 March 2020
Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6927862
15 March 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6643395
3 March 2019
Damage Survey
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6635924
3 March 2019
Type not recorded
No type recorded · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6638183
22 March 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6376991
20 March 2018
Hull Examination · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6374966
13 July 2017
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6207437
21 April 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5859682
19 April 2016
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5857826
5 July 2012
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4368803
17 February 2012
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4246818
16 February 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4253718
30 September 2011
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4157894
10 July 2008
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3264291
1 July 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3253687
4 June 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3226930
10 March 2008
Damage Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3161545
5 March 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3160093
18 June 2007
Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2966197
14 June 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2961708
12 September 2006
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2776785
23 June 2005
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2399943
16 June 2005
Hull Examination · MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2392537
10 January 2005
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2272207
9 January 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2274971
21 July 2004
Damage Survey · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2140365
29 August 2003
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1890852
27 June 2003
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1828151
3 January 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1727967
8 August 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1658607
27 February 2002
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1651344
29 June 2001
Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1432549
8 June 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1420327
16 June 1999
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1375807
15 July 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1388576
18 June 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 108516
11 June 1997
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364197
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 27 February 2025
Resolved
Fuel lines must be annealed tubing of copper, copper nickel or copper-nickel-copper having minimum wall thickness of .9mm.
Fuel line on #4 MDE is missing mount and is showing chafing. Correct and notify OCMI.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 28 February 2025
Resolved 28 February 2025
Resolution: vessel replaced lines
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 27 February 2025
Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel in compliance with 177.970 of 46CFR. Temp that exceeds 150 degrees Fahrenheit must be insulated where necessary to prevent injury.
Lagging on MDE(all) missing in sections. Repair notify OCMI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2025
Resolved 10 March 2025
Resolution: Vessel repaired insulation on MDEs, no more exposed areas.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 17 May 2023
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR Part 80. The VHF radio's DSC capability was inoperable at time of inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 22 May 2023
Resolution: DSC Programmed and tested.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 May 2023
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessels mast head light was inoperable at time of inspection.
**Correct prior to nighttime voyage or restricted visibility. Correct no later than 14 days.**
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 22 May 2023
Resolution: Light replaced.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 17 May 2023
Resolved
On a vessel of more than 65 feet in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members [name withheld] system not audible in crew accommodation area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 22 May 2023
Resolution: PA Fixed
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 May 2023
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 52 inches high: “EMERGENCY EXIT, KEEP CLEAR". FWD Main Deck escape hatch not labeled outside.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 22 May 2023
Resolution: Labeled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 17 May 2023
Resolved
Each vessel must comply with the Type II subdivision and damage stability requirements. Vessels E/R and Rudder Room hinged watertight doors not fully watertight at time of inspections.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 22 May 2023
Resolution: Made watertight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 April 2021
Resolved
Watertight doors shall be designed to withstand 10 ft head of water. Watertight doors to the generator and rudder compartment were not watertight. 46 CFR 170.270
Action required: 10 - Deficiency Rectified
Due 29 April 2021
Resolved 29 April 2021
Resolution: watertight doors were adjusted and made watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 April 2021
Resolved
Bilge pipe suction shall have a strainer at least 3 times the pipe diameter. Rudder compartment bilge piping missing strainer. 46 CFR 182.510 (b)
Action required: 10 - Deficiency Rectified
Due 29 April 2021
Resolved 29 April 2021
Resolution: strainer was installed into rudder room bilge piping
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 March 2020
Resolved
Nonmetallic flexible hoses must be in accordance with SAE J1942 and may be used in lube oil, fuel oil, and fluid power systems only where flexibility is required and in lengths not exceeding 30". MI noted several nonmetallic flexible hoses on #1 and #2 main diesel engines that were deteroriated and unserviceable. Owner shall replace the identified hoses below with satisfactory SAE J1942 or equivalent nonmetallic flexible hoses.
1. #2 Fuel Pressure Hose
2. #1 Reduction gear hydraulic hoses
3. #2 Reduction gear hydraulic hoses
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2020
Resolved 24 March 2020
Resolution: Resolved to satifaction of MI.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 March 2019
Resolved
Vessel sustained damage to the bow and forepeak; bow is
inset approximately 2.5'; forepeak ruptured at the peak
of bow; proceed to dock for repairs via protected waters
route only.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 April 2019
Resolved 15 March 2019
Resolution: Repairs were completed to the satisfaction of the attending marine inspector, NDT was completed to all watertight compartments involved.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 March 2019
Resolved
Whistle dB does not comply with audibility requirements
of the Inland Navigation Rules correct prior to
operating in restricted visibility.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2019
Resolved 15 March 2019
Resolution: Ship's whistle was repaired to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 3 March 2019
Resolved
The rescue platform was crushed by the bow bulwarks. Repair and replace prior to departure from repair facility.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 April 2019
Resolved 15 March 2019
Resolution: Rescue platform was repaired to the satisfaction of the attending marine inspector.
Engineering › Diesel Engine (propulsion-electric) › Emergency shutdown
Issued 13 July 2017
Resolved
EMERGENCY STOP FOR #2 MDE NOT FUNCTIONING.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 July 2017
Resolution: REPLACED #2 MDE EMERGENCY STOP SOLENOID WITH NEW UNIT.
Engineering › Diesel Engine (auxiliary) › Diesel Engine Relating to Air Pollution Control
Issued 13 July 2017
Resolved
PORT AND STBD GENERATOR EXHAUST SUPPORT HANGERS BROKEN. REPLACE WITH NEW METAL.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 July 2017
Resolution: NEW METAL WELDED HANGERS PLACED ON PORT AND STBD HANGERS.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 13 July 2017
Resolved
EXHAUST LEAK THROUGH CRACK ON PORT GENERATOR.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 July 2017
Resolution: CRACK WELDED AND SEALED FROM LEAKING.
Navigation › Piloting/Steering › Notices to Navigation
Issued 13 July 2017
Resolved
CHART CORRECTIONS NOT BEING UPDATED.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 July 2017
Resolution: MASTER PROVIDED CURRENT CHARTS AND CROSS CHECKED CURRENT NOTICE TO MARINERS UPDATES.
Documentation › Certificates/Documents › Stability Letter
Issued 5 July 2012
Resolved
Vessel is not in compliance with Assumed Average Weight Per Person (AAWPP) standards in accordance with Marine Safety Bulletin 001-11.
Action required: 705 - Other - as specified
Resolved 17 September 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 10 March 2008
Resolved
Recharge fixed CO2 system
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2008
Resolution: System recharged and checked by service tech.
Engineering › Diesel Engine (propulsion-direct drive) › Blower, Centrifugal
Issued 10 March 2008
Resolved
Determine cause of engine fire
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2008
Resolution: Broken shaft resulting in L/O spraying on exhaust manifold caused fire.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 10 March 2008
Resolved
Prove proper operation of Port & Stbd I/B main engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2008
Resolution: During SIP inspection witnessed proper operation of port & stbd inboard main engines ahead and astern. All gauges on the bridge were operational. Marine Systems, Inc service report scanned in documentation.
Construction/Loadline › Hull › Stiffener
Issued 27 June 2003
Resolved
Provide at next drydock two (2) each hull plate stiffiners just out board of vessel keel port/stbd in fwd ballast tank.
Action required: 705 - Other - as specified
Due 24 July 2005
Resolved 17 June 2005
Resolution: Installed (2) each hull plate stiffeners just outboard of vessel keel port/stbd in fwd ballast tank. Inspected to the satisfaction of the attending marine inspector.
Navigation
Issued 27 June 2003
Resolved
Provide rudder angle indicator as required by 46 CFR 182.610.
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 29 August 2003
Resolution: Witnessed operation of the rudder angle indicator.
Navigation
Issued 27 June 2003
Resolved
Provide steering motor run indicator lights at steering station as required by 46 CFR 182.610.
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 29 August 2003
Resolution: Witnessed operation of newly installed indicator lights for the steering system.
Navigation
Issued 27 June 2003
Resolved
Provide means to center and steady rudders as required by 46 CFR 182.610.
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 29 August 2003
Resolution: Witnessed installed chains provided to center rudders in an emergency.
Engineering
Issued 27 June 2003
Resolved
Demonstrate proper operation of generator overspeeds.
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 29 August 2003
Resolution: Witnessed operation of generator overspeeds.
Documentation
Issued 11 June 1997
Resolved
PROVIDE ONBOARD A VALID FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997