MAURY USCG vessel records
← All vessels

MAKANA

Built
1994
Last inspected
14 March 2025
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 March 2025
…with no type recorded3
…past their stated due date2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL7277
413226
Flag
UNITED STATES
Maury page id
psix-413226

Documentation record

Registered dimensions (L × B × D)32.0 ft × 10.1 ft × 5.0 ft
Registered tonnagegross 8 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLIGHTNIN FIBERGLASS · KILAUEA, HI, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portWAIMEA, HI
Endorsements, as the file codes themcw_un, rec
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 19 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each, 2 without one; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEIKO Passenger (Inspected) · MISLE 1583364 · 15 July 2021 · activity 7265850

Inspection history · 19

14 March 2025 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8096509
6 March 2024 Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7875706
28 February 2023 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7644570
12 July 2022 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7504319
12 July 2022 Simplified Stability Test
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7546770
9 July 2022 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7504104
21 June 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7483618
8 March 2022 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7402894
15 July 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7265850
19 May 2021 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7202108
4 December 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7106478
14 July 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7007085
9 June 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6973250
26 August 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6795521
18 March 2019 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6645402
5 June 2018 Deficiency Check · Administrative Inspection · Drydock Exam · DAPI Audit · Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6435264
25 May 2018 Type not recorded
No type recorded · Station Kauai · USCG Oceania District (CGD-O) · Activity 6424456
21 February 2017 DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6092074
29 June 2016 DAPI Audit · Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5924018

Deficiency record · 9

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 March 2025 No resolution recorded
Vessel's gas tanks are leaking fuel into it's compartment. Provide capable tanks of holding head psi of 5 psi. Prior to installation, tanks vented to the atmosphere must be hydrostatically tested to, and must withstand a pressure of 5 psi or 1 1/2 time the working pressure head to which they may be subjected in service. Prove tanks are satisfactory installed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 March 2025 No resolution recorded
Due to gas tanks leaking fuel, propulsion test were not completed. Vessel needs to complete sea trails to ensure propulsion machinery is suitable and capable of operating t constant marine loads. Prove vessel's engines are capable for the vessel service and has two means of stopping.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2025 — due date passed with no resolution recorded
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 12 July 2022 Resolved
Vessel swapped out inboard engines for outboard engines in 2017. The weight change was never calculated and OCMI is requesting a stability test. Prove vessel is stable for exposed routes within 30 days or routes will be reduced to limited coastwise.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 22 August 2022
Resolution: Vessel completed a satisfactory SST in the presence of two attending MIs.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 March 2022 Resolved
Portable fire extinguishers shall be services IAW NFPA 10. MI found both fire extinguishers unserviceable. Provide annual servicing and prove proper install.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2022
Resolved 9 March 2022
Resolution: Newv servicable fire extinguishers installed onboard vessel.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 8 March 2022 Resolved
Vessel shall have visual and audible alarm for high level in bilge areas. MI found bilge alarms not capable of alarming. Provide repairs and prove alarms work.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2022
Resolved 9 March 2022
Resolution: Bilge alarms are functioning and capable of giving an audible and visual alarm to the operation station.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 July 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 18 August 2020
Resolution: Recieved a new valid FCC Station License.
Fire Fighting › Ventilation Systems › Fans
Issued 5 June 2018 Resolved
Vessel with gasoline tanks in partially enclosed spaces are required at least one supply and one exhaust vent and a powered mechanical blower must be fitted in the exhaust ducting. The vessel currently does not have any venting for the two fuel tank compartments. Provide and install approved venting for the two fuel tank compartments.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 18 March 2019
Resolution: Powered ventillation provided for the fuel tank spaces.
Engineering › Fuel Oil Service System › Valve
Issued 5 June 2018 Resolved
46 CFR 182.455(b)(4) shut off valves must be provided in fuel lines at the tank. The vessel has two independant permanently mounted fuel tanks and no shut off valves are installed. Provide a shut off valvle at each tank.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 13 June 2018
Resolution: Proper shutoff valves were installed and tested.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 June 2018 Resolved
Each ring buoy must be marked with the vessels name. The provided ring buoy was not marked with the vessels name. Provide proper markings on the required ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 13 June 2018
Resolution: Ring buoy was properly marked.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.