Inspection history · 61
27 January 2014
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4789693
23 May 2005
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2365761
22 February 2005
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2297009
16 February 2005
Administrative Inspection · Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2293590
29 January 2005
Permit to Proceed · Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2283573
29 January 2005
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2296832
8 December 2004
Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2255800
10 October 2004
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2217761
23 June 2004
In-Service Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2153503
22 March 2004
Periodic Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2028889
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1973562
4 September 2003
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1896366
2 September 2003
Permit to Proceed
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1895019
23 August 2003
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1896091
19 February 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1746073
7 August 2002
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1657997
16 May 2002
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1616928
15 March 2002
Internal Structural Exam · Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1493885
25 November 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1491697
28 June 2001
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1067369
14 February 2001
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1417215
7 February 2000
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1046523
22 March 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 30540
18 March 1999
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1120351
2 April 1998
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1122711
4 April 1997
COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1097025
9 January 1996
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 881826
8 March 1995
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 859500
15 February 1995
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1154460
14 July 1994
Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 869822
5 January 1994
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 850345
5 March 1993
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 834371
8 December 1992
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 471352
20 August 1992
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1254326
24 February 1992
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 690341
28 January 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1268117
27 January 1992
Re-Inspection · Deficiency Check · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1314483
9 December 1991
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 487509
19 July 1991
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1251772
21 June 1991
Permit to Proceed
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1245282
1 April 1991
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 905105
1 April 1991
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1212606
13 March 1991
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 493924
2 April 1990
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 907052
25 January 1990
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 491364
28 March 1989
COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 893312
27 May 1988
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 462747
23 May 1988
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1043839
18 May 1988
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1350533
8 October 1987
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 514233
2 June 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1336298
4 April 1987
COI Inspection · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1023334
5 September 1986
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 516283
24 March 1986
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 499064
14 March 1986
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1302171
3 June 1985
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 490311
29 April 1985
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 981509
18 April 1985
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 980176
29 November 1984
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 449240
31 May 1984
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 537734
15 March 1984
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1280335
Stability › Unintentional Flooding › General
Issued 29 January 2005
Resolved
Monitor starboard #4 void and control flooding as required to maintain water free condition. If condition changes report to [name withheld] offload, and prior to reloading or departing [name withheld] zone, make barge available for internal exam of Stbd #4 void, and submit for approval written repair proposal.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 26 September 2016
Resolution: Vessel Inactive
Construction/Loadline › Hull › Hull Plating
Issued 10 October 2004
Resolved
Vessel rep reported a 1 inch fracture between the 4 and 5 foot draft mark. Fracture has been shingled and reduced the water ingress to 0. vessel was autorized to transit to Pitt Penn docks Craton PA to discharge present cargo. Vessel in returning to this area for rerpairs. GS
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 December 2004
Resolution: Permanent repairs conducted, all sat.
Construction/Loadline › Hull
Issued 23 August 2003
Resolved
Damage: 1/4 inch puncture on starboard bilge knuckle at the stern void. Requirements: 1. Post standby pumps IVO stern void throughout transit and 2. No cargo operations are permitted (after offloading) until permanent repairs had been made and witnessed by a CG Marine Inspector LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 September 2003
Resolved 17 September 2003
Resolution: Conducted visual inspection of all repair welds and witnessed airtest while in dry dock. All sat, vessel cleared to sail.
Construction/Loadline › Hull › Bottom Plating
Issued 7 August 2002
Resolved
Repair stbd transition knuckle area of wastage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2002
Resolution: 7'' x 5''6" x 1/2" knuckle insert.
Construction/Loadline › Hull › Bottom Plating
Issued 16 May 2002
Resolved
Stern bottom plating wasted / holed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2002
Resolution: 12'' x 33'' x 3/8" stern bottom plate insert.
4''6" x 5'' x 3/8" bottom plate insert #4 wing void
3'' x 4'' x 1/2" stbd knuckle insert #4 wing void
Deck/Cargo
Issued 15 February 1995
Resolved
MAKE VAPOR COLLECTION PIPING ACCESSIBLE TO BE INTERNALLY EXAMINED.
Condition: Unknown
Due 15 February 1995
Resolved 15 February 1995
Deck/Cargo
Issued 19 July 1991
Resolved
VAPOR RECOVERY OPERATIONS SHALL NOT BE CONDUCTED UNTIL THE VAPOR RECOVERY SYSTEM HAS BEEN APPROVED BY USCG (G-MSC) IAW 46 CFR 39.10.13 AND THE COI HAS BEEN AMENDED TO AUTHORIZE VAPOR RECOVERY OPERATIONS.
Condition: Unknown
Due 19 July 1991
Resolved 19 July 1991
Construction/Loadline
Issued 18 May 1988
Resolved
REPAINT VESSEL DRAFTMARKS AND HOMEPORT AND NAME ON HULL.
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Construction/Loadline
Issued 14 March 1986
Resolved
PRESENT EXTERIOR HULL FOR COAST GUARD INSPECTION PRIOR TO NEXT CARGO LOADING.
Condition: Unknown
Due 14 March 1986
Resolved 14 March 1986
Construction/Loadline
Issued 18 April 1985
Resolved
INSTALL COAST GUARD APPROVED FLAME SCREENS ON ALL WING VOID GOOSENECK VENT PIPES
Condition: Unknown
Due 18 April 1985
Resolved 18 April 1985