Records from 1994 to 2022. Most recent: operational control imposed, 29 November 2022.
Inspection history · 76
29 November 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7601169
2 July 2022
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7492993
27 February 2022
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7402607
20 August 2021
PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7292006
24 May 2021
Deficiency Check · Administrative Inspection · PSC A
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7200956
5 April 2021
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7168997
4 March 2021
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7150343
8 February 2021
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7137367
30 January 2021
Administrative Inspection · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7133405
22 August 2020
Administrative Inspection · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7039907
8 July 2020
PSC A
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6992624
25 May 2020
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6959936
15 November 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6853545
27 December 2018
PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6603146
28 August 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6525081
29 May 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6427241
16 April 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6392222
8 March 2018
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6363072
3 February 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6348997
3 February 2018
NPV Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6350556
26 January 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6344164
27 November 2017
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6313063
13 October 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6286987
18 September 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6269151
8 August 2017
ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6233854
10 May 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6138699
10 May 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6143085
6 March 2017
Ballast Water Examination · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6099344
12 September 2016
In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5998546
8 March 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5828257
18 September 2015
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5722305
16 September 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5721049
9 September 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5718396
28 October 2014
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5013580
4 March 2014
PII Safety Exam · Attraction Vessel Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4809591
23 July 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4388279
18 July 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4382674
23 December 2011
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4213044
1 September 2011
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4132780
6 December 2010
Random ISPS/MTSA/PSC · Administrative Inspection · NPV Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3904893
16 January 2010
Random ISPS/MTSA/PSC · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3664971
29 March 2009
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3442211
23 March 2009
Administrative Inspection · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3438564
10 October 2008
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3341658
16 April 2008
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3186834
11 September 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3055217
7 September 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3054949
28 June 2007
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2976248
25 April 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2915743
24 March 2007
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2894030
15 March 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2888471
15 March 2007
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2890640
9 August 2006
ILO-147 Exam · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2741748
1 June 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2667280
4 May 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2640613
9 April 2006
Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2623803
6 September 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2485157
21 July 2005
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2434090
7 July 2005
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2418069
16 May 2005
MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2359323
7 January 2005
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2270422
15 July 2004
ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2133995
29 April 2004
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2055376
5 March 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2018570
22 September 2003
MARPOL Annex I Examination · MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1910166
27 January 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1735742
18 January 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1734215
16 January 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1731225
3 September 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 281664
16 December 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 435855
12 November 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 422614
23 October 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 409099
16 March 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 388921
8 December 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 486625
8 December 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 833307
8 December 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1142744
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 May 2021
Resolved
07113 – Fire pumps and it's pipes – The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed without changes to the ship or persons on board. PSCO observed approximately 1 cm diameter hole in fire main located in lower deck outside the handling room – SOLAS (20) I/11
17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2021
Resolution: Vsl submitted class report from DNV issued on 27May21 attesting to repairs. See attached document.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 May 2021
Resolved
07106 – Fire dertection and alarm system – Any required automatic fire detection system shall be capable of immediate operation at all times.Inoperable smoke detector in lower deck outside the handling room. – SOLAS (97) II-2/12.1.1
17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2021
Resolution: Vsl submitted class report from DNV attesting to repairs. See attached document.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 30 January 2021
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The steering system on the freefall lifeboat was found inoperable. Upon further inspection, the crew found an issue in the shaft making the rudder hard to operate. The hydraulic oil was replaced and the hydraulic system was found to be in good condition. After detaching the hydraulic from the shaft, the crew was able to isolate the malfunction to the rotation of the shaft. This was confirmed by their inability to steer the rudder with the emergency tiller. 74SOLAS(14) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2021
Resolution: See attached Class Report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 30 January 2021
Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The steering system on the freefall lifeboat was found inoperable. Upon closer inspection of the ship's log for their lifesaving equipment, it was discovered there are no checklists with clear and adequate instructions for the monthly inspections. Recommend SMS audit within 30 days. 02 74 SOLAS (14) IX/3.1, ISM Code A/10.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2021
Resolved 26 March 2021
Resolution: USCG satisfied with ISM Shipboard Audit Report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 August 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel's #2 generator experienced a casualty while transiting inbound to the Port of Wilmington. 74SOLAS(2004) I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 22 August 2020
Resolved 28 August 2020
Resolution: Received Class Survey Attesting to the repairs. Class has no objection for vessel to continue trading.
Navigation › Collision/Grounding Avoidance › Radar
Issued 3 February 2018
Resolved
1530- Radar - All ships of 3,000 GT and upwards shall, in addition to meeting the requirements of paragraph 2.5, have: a 3GHz radar or, where considered appropriate by the Administration, a second 9GHz radar, or other means, to determine and display the range and bearing of other surface craft, obstructions, buoys, shorelines and navigational marks to assist in navigation and collision avoidance. The secondary radar screen is not functioning.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 March 2018
Communications › Radio Communications › EPIRB
Issued 23 March 2009
Resolved
Ran Unsuccessful test of EPIRB. Lamp did not ignite. Manufacturers’ statement reads for test: "One Flash in the strobe light. Any other behavior indicates a fault in the beacon". EPIRB Shall be capable of being activated manually.
74 SOLAS 2004 Consolidated IV/8.3.5
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2009
Resolution: Received the service report and reciept that the vessel purchased and registered a new EPIRB to replace the one onboard that was not working properly.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 10 October 2008
Resolved
0699 - Life saving appliance - Found 14 food rations not to be airtight, vessel needs 10 food rations to be in compliance with the code. Fax Receipt of food rations to Sector Delaware Bay. SOLAS 74 CONS ED 2004 CH III Reg 13.4 (LSA CH IV 4.1.5.1.18)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2008
Resolution: Received Fax of purchase of (10) Lifeboat Rations
Personnel › Training › Cargo Safety
Issued 15 March 2007
Resolved
ALL CREW ARE REQUIRED TO BE TRAINED IN ENCLOSED SPACE PROCEDURES AND DEMONSTRATE PROPER PROCEDURES FOR ENTERING A CONFINED SPACE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 20 March 2007
Resolution: WITNESS SATISFACTORY ENCLOSED PROCEDURE IAW REVISED PROCEDURES. CLASS AND REP FROM FLAG WERE IN ATTENDANCE.
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 15 March 2007
Resolved
A VISUAL INSPECTION OF THE #1 CARGO HOLD IDENTIFIED A FAILED RUPTURE DISK IN THE #1 CARGO HOLD OVERFLOW TANK WHICH IS COMMON TO THE NITROGEN PIPING SYSTEM. PRIOR TO DEPARTURE, VERIFY THE PROPER OPERATION OF THE NITROGEN PIPING SYSTEM IN CARGO HOLD #1 INCLUDING A PRESSURE TEST AND OPERATION OF ALL SAFETY VALVES.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 19 March 2007
Resolution: WITNESSED SATISFACTORY PRESSURE TESTING OF #1 CARGO HOLD NITROGEN PIPING SYSTEM AND DETERMINED THAT NO OTHER LEAKS WERE IN THE SYSTEM.
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 15 March 2007
Resolved
PRIOR TO DISCHARGE AT THE NEXT PORT, THE SHIP SHALL CONDUCT A PRESSURE TEST TO ENSURE THAT THE NITROGEN PIPING SYSTEM IN CARGO HOLDS 2,3, AND 4 HAS NOT BEEN COMPROMISED AND A SAFETY CHECK OF ALL SAFETY VALVES RELATED TO THOSE SPACES.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2007
Resolved 24 March 2007
Resolution: Attended vessel at Wilmington Marine Terminal, Wilmington DE, reviewed class (GL) survey report. Report indicates all associated piping and safety valves have been pressure tested to 140 millibar, all sat.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 15 March 2007
Resolved
OXYGEN SENSORS WERE ONLY PROVIDED IN THE BOTTOM OF CARGO HOLDS. WITH THE POTENTIAL FOR NITROGEN GAS TO BE EMITTED THROUGH RUPTURE DISCS IT IS RECOMMENDED THAT THE FLAG DETERMINE IF ADDITIONAL OXYGEN SENSORS SHOULD BE PLACED IN THE UPPER PORTION OF THE CARGO HOLDS.
Action required: 705 - Other - as specified
Due 20 June 2007
Resolved 28 June 2007
Resolution: OXYGEN SENSORS ON ORDER, WILL BE PLACED IN CORRECT LOCATION OF HOLD UPON RECIPT
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 15 March 2007
Resolved
CLASS SHALL VERIFY A SATISFACTORY TESTING OF THE OVER-FLOW ALARM TESTING AT THE EARLIEST CONVENIENCE IF THE ALARM CANNOT BE TESTED SAFELY AT THE NEXT LOADING/DISCHARGING PORT AND DOCUMENTATION OF THE TEST SHALL BE PROVIDED TO SECTOR ST. PETERSBURG.
Action required: 705 - Other - as specified
Resolved 28 June 2007
Resolution: CLASS VERIFIED TESTING OF ALARM. ALARM WILL BE TESTED PRIOR TO PORT.
Deck/Cargo › Cargo Refrigeration › General
Issued 15 March 2007
Resolved
NO PROCEDURES OR DOCUMENTATION WERE PROVIDED TO: DOCUMENT AND MAINTAIN RECORDS OF HIGH LEVEL ALARMS, REPORT POTENTIAL HAZARDOUS SITUATIONS DURING LOADING/UNLOADING, AND/OR TAKE APPROPRIATE CORRECTIVE ACTIONS. IT IS STRONGLY RECOMMENDED THAT THE SMS BE AUDITED AND UPDATED TO PROVIDE DETAILED PROCEDURES.
Action required: 705 - Other - as specified
Due 20 June 2007
Resolved 28 June 2007
Resolution: AUDIT WAS PERFORMED, RECORD OF TEST HAVE BEEN PROVIDED.
Navigation › Collision/Grounding Avoidance › Radar
Issued 4 May 2006
Resolved
INOP RADAR
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2006
Navigation › Collision/Grounding Avoidance › Radar
Issued 6 September 2005
Resolved
Sector Delaware Bay issued LOD 41-05 to M/V Sol Do Brasil for an inoperable radar. LOD was valid for one transit of the Delaware River to Wilmington Marine Terminal.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2005
Resolved 6 September 2005
Resolution: Sector Delaware Bay rescinded LOD 41-05 to M/V SOL DO BRASIL for inoperable radar, after receiving tech report that the radar had been inspected, tested, and was operating properly to the satisfaction of the repair tech.
Operations/Management › Pollution › Control of Garbage
Issued 21 July 2005
Resolved
Vessel's crew not segregating trash in accordance with waste managment plan. 33CFR151.63(b)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2005
Resolution: Vessel''s crew segregated trash and was verified by USCG.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 16 May 2005
Resolved
Provide gratings or other non slip surface to the steering gear spaces to prevent accidents/slippage.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 July 2005
Resolution: Received Class Report attesting repairs.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Crankcase
Issued 16 May 2005
Resolved
Identify source of excessive oil leak above the main engine portside covers at the scavenge air unit and conduct repairs to stop the leak.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 July 2005
Resolution: Received Class report attesting to repairs.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 May 2005
Resolved
Make the operating stand for the #1 steering gear pump available for safe and convenient use. Currently there are two 55 gallon drums directly in front of this operating station.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 July 2005
Resolution: Received Class report attesting to repairs.
Lifesaving › Lifeboat › Propeller Shaft
Issued 16 May 2005
Resolved
Repair the propeller shaft for the stern launched lifeboat. The shaft is bent causing the propeller to hit the propeller shroud.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 July 2005
Resolution: Received Class report attesting to repairs and sat results.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 16 May 2005
Resolved
Clean and re-attach all plugs for the fuel oil fixed containment on main deck. Fuel oil containment plugs threads are painted over.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 July 2005
Resolution: Received Class report attesting to proper repairs.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 7 January 2005
Resolved
Echo depth sounding recorder not operating as required by 33 CFR 164.35(h).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2005
Resolution: Received technicians report from Maritime Electronics, Co. attesting to proper function of echo depth sounding recorder.
Fire Fighting › Combustible Materials
Issued 5 March 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2004
Resolved 5 March 2004
Resolution: RECEIVED CLASS REPORT FROM GL ATTESTING TO WASTE OIL REMOVAL FROM STEERING GEAR ROOM. DEFICIENCY CLEARED.
Deck/Cargo › Mooring/Anchoring
Issued 5 March 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2004
Resolved 5 March 2004
Resolution: RECEIVED CLASS REPORT ATTESTING ABOVE DEFICIENCY TO BE CORRECTED AT NEXT VESSEL DRYDOCK. DEFICIENCY CLEARED.
Deck/Cargo › Mooring/Anchoring
Issued 5 March 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2004
Resolved 5 March 2004
Resolution: RECEIVED CLASS REPORT FROM GL ATTESTING THAT DEFIENCY TO BE ADDRESSED AT NEXT VESSEL DRYDOCK. DEFICIENCY CLEARED.
Electrical › Electric Generation Source (emergency)
Issued 5 March 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2004
Resolved 5 March 2004
Resolution: RECEIVED CLASS REPORT FROM GL ATTESTING TO SATISFACTORY REPPAIR OF EMERGENCY GENERATOR. DEFICIENCY CLEARED.
Pollution Prevention/Response › Prevention Equipment
Issued 5 March 2004
Resolved
VESSEL HAS NO MECHANICAL MEANS OF SECURING DECK DRAINS DURING U.S. BUNKERING, A VIOLATION OF 33 CFR 156.120(o). CORRECT WITHIN 30 DAYS OR PRIOR TO NEXT U.S. BUNKERING OPERATIONS. LEGACY COMPONENT DESC: Drains/Scuppers (means of closure)
Condition: Placed in Improper Service
Action required: 703 - Prior to bunkering operations
Due 5 April 2004
Resolved 29 April 2004
Resolution: MSO PHILADELPHIA OBSERVED THE VESSELS NEW SCUPPERS WITH A MECHANICAL MEANS TO SECURE DECK DRAINS.
Lifesaving › Lifeboat Equipment
Issued 16 January 2003
Resolved
04 food rations in lifeboat were wasted and must be replaced with new. Solas 74/78, Ch. III, Reg. 41.8.12. Correct within 30 days to meet full capacity of lifeboat. LEGACY COMPONENT DESC: Food Ration
Condition: Unknown
Due 16 February 2003
Resolved 21 January 2003
Resolution: Received a faxed copy of a receipt for purchase of 04 food rations to replace those that were wasted.
Communications › Radio Communications
Issued 16 January 2003
Resolved
INMARSAT Ship Earth Station is inoperable. Solas 74/78, Ch. IV, Reg. 7.1.5. Correct Prior to departure from port. LEGACY COMPONENT DESC: Satellite Communications Capability
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2003