Records from 1985 to 2026. Most recent: inspection, 7 April 2026.
Inspection history · 98
7 April 2026
Damage Survey · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8344184
27 August 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8218704
9 December 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8044916
11 August 2024
Annual Inspection · Administrative Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7979097
14 September 2023
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7791505
30 March 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7663349
26 August 2022
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7544203
12 August 2021
COI Inspection · Internal Structural Exam · Administrative Inspection · Inclining Experiment · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7279117
25 October 2019
Internal Structural Exam · Drydock Exam · Plan Review "T" Boat
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7281395
23 July 2019
Annual Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6759297
6 June 2019
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6705203
9 April 2019
Drydock Extension · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6760789
16 July 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6480989
8 July 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6477039
7 July 2018
Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6472815
25 April 2017
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6132362
19 April 2017
Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6128429
13 March 2017
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6106823
13 March 2017
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6113680
12 July 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5937719
29 March 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5842841
5 October 2015
Internal Structural Exam · Drydock Extension
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5734377
2 June 2014
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4877474
19 July 2011
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4087330
16 March 2010
Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3701332
14 May 2009
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3474162
19 May 2008
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3211028
31 January 2008
Drydock Exam · Internal Structural Exam · Deficiency Check · Drydock Extension
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3139759
27 October 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3088079
26 April 2007
COI Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2916772
7 August 2006
MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2739063
22 November 2005
Deficiency Check · Plan Review "T" Boat · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2554282
26 April 2005
MARPOL Annex V Examination · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2343380
26 July 2004
Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2145173
31 March 2004
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2034492
9 June 2003
MARPOL Annex V Examination · Annual Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1812934
25 June 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1636016
20 May 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1618715
19 March 2002
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1494937
16 July 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1070735
25 May 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1395756
7 March 2001
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1060457
1 March 2001
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1058024
28 August 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 821631
16 August 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 821157
20 June 2000
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1050924
16 June 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1852442
4 May 2000
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 820970
14 April 2000
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1406670
2 March 2000
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1061233
25 February 2000
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1052724
23 September 1999
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1036591
9 September 1999
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1470995
12 May 1999
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1440129
15 May 1998
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1126446
16 October 1997
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1110339
12 May 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1100868
5 June 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 144363
24 May 1996
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1085961
13 May 1996
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1082227
13 November 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1190081
9 May 1995
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1234292
13 May 1994
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1183124
12 May 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1183044
28 September 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 844455
17 May 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 832297
29 October 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 827743
31 August 1992
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1266712
5 May 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1254862
9 July 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1247978
26 April 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249072
6 March 1991
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1238938
5 December 1990
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 907932
13 November 1990
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 926687
23 October 1990
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1222700
22 October 1990
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1216057
18 May 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1229139
20 April 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 908924
7 July 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1348615
15 May 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 894839
16 March 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1199020
29 September 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1351625
26 September 1988
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1195243
19 May 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1351187
18 April 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1341136
18 March 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1336595
10 November 1987
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1334511
6 October 1987
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1321893
18 May 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1332872
29 April 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1330200
7 April 1987
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020847
11 March 1987
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1015950
25 July 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 998439
8 July 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1292956
25 June 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 985392
17 March 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1305472
6 June 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 987655
19 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 980521
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 April 2026
Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. While moored, vessel experienced an allision with the M/V CIRCLE LINE BROOKLYN causing minor damage to the jib-boom. Make appropriate repairs to boom and its metal cap.
46 CFR 177.330
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 13 April 2026
Resolution: Received and reviewed documenting proper repairs to jib-boom and cap.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2024
Resolved
MAIN ENGINE REMOTE FUEL SHUT-OFF VALVES MUST OPERATE TO SECURE THE SUPPLY FLOW OF FUEL FROM THE STORAGE TANKS TO ENGINES. BOTH PORT & STBD FUEL SHUT-OFF PULL CABLES WERE OBSERVED TO NOT FULLY CLOSE SUPPLY VALVES. ADJUST / REPAIR / REPLACE TO [name withheld].
46 CFR 455(b)(4)
46 CFR 187.20-40(b)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2024
Resolution: Rcvd sat evidence of def correction, properly operating fuel ROV.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 August 2024
Resolved
OVERCURRENT ELECTRICAL PROTECTION COMPONENTS MUST BE OF CARTRIDGE OR BREAKER TYPE. IN-LINE BLADE (AUTOMOTIVE STYLE) FUSES ARE NOT PERMITTED. ENGINE ROOM 12V BREAKER PANEL FOR BILGE ALARMS & VHF RADIO WAS FOUND TO HAVE BLADE STYLE FUSE. REPLACE / RENEW WITH REQUIRED STYLE OVER-CURRENT PROTECTION TO USCG [name withheld] 30 DAYS.
NOTE: IF ALTERING / MODIFYING ELECTRICAL SYSTEM, NOTIFY OCMI OFFICE TO ENSURE PROPER PLAN REVIEW AND OVERSIGHT.
46 CFR 183.350
46 CFR 183.10-35 (-40)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 October 2024
Resolution: Rcvd sat evidence of proper fuse replacement.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 26 August 2022
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level alarm. MI discovered that the visual/audible alarm was located in the engine space and not at the operating space. Deficiency will be rectified prior to next drydock (June 2023)
Action required: 705 - Other - as specified
Resolved 14 September 2023
Resolution: Vessel installed a high water alarm panel at the operating station. Verified the alarms during annual inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 August 2022
Resolved
The design, material, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. MI discovered missing rigging components. Operator & crew shall visually inspect/replace all missing rigging components.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 September 2022
Resolution: Received photographs (see documents) of secured rigging components. Operator used "nyloc" lock nuts to secure all rigging components.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 August 2021
Resolved
Each floating waterlight must be attached by a lanyard.
Lanyard on port ring buoy is beginning to fray and requires replacement/repair.
46CFR180.71(d)
50C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 September 2021
Resolution: Received documentation attesting to rectification of deficiency.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 July 2019
Resolved
A VESSEL SHALL BE FITTED WITH A VISUAL AND AUDIBLE HIGH WATER ALARM IN ANY SPACE THAT IS SERVED BY A NON-WATERTIGHT HATCH. THE BILGE ALARM FOR THE MIDSHIPS BILGE DID NOT PROPERLY ILLUMINATE WEHN THE ALARM WAS ACTIVATED.
46CFR182.530(a)(3)
46CFR182.115(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 6 August 2019
Resolution: Cleared by [name withheld].
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 23 July 2019
Resolved
VESSELS AND THEIR EQUIPMENT SHALL BE MAINTAINED IN ACCORDANCE WITH GOOD MARINE PRACTICES. THE HIGH BILGE WATER ALARM FLOAT SWITCH WAS NOT SECURED IN ITS POSITION AND FREELY MOVED WITHIN THE BILGE.
46CFR176.25-50(a) "OLD T"
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 6 August 2019
Resolution: Cleared by [name withheld].
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2019
Resolved
ELECTRICAL INSTALLATIONS SHALL BE MADE IN A MANNER TO PROTECT THE CREW, PASSENGERS, AND SHIP FROM HAZARDS. THERE WAS A JUNCTION BOX AND AN OUTLET BOX THAT WERE NOT PROPERLY MOUNTED AND WERE ALLOWED TO SWING FREELY IN THE FORWARD STARBOARD PORTION OF THE MIDSHIPS VOID.
46CFR183.200
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 6 August 2019
Resolution: Cleared by [name withheld].
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 July 2019
Resolved
EACH SURVIVAL CRAFT SHALL BE MAINTAINED IN AN OPERATIONAL READY CONDITION, HAVING MAINTENANCE CONDUCTED IN ACCORDANCE WITH MANUFACRTURER'S REQUIREMENTS. VESSEL'S LIFE FLOAT HAD SEVERAL AREAS WHERE THE COATING WAS TORN, AS WELL AS MULTIPLE REPAIRS
THAT WERE PREVIOUSLY MADE. REPAIR IAW MANUFACT REQS.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 6 August 2019
Resolution: Cleared by [name withheld].
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2019
Resolved
Operator voluntarily placed vessel out of service until repair work can be completed for faulty engine block. Operator must submit engine repair/replacement proposals for review.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2022
Resolution: approved inspection recieved
Navigation › Piloting/Steering › Marine Charts
Issued 26 April 2017
Resolved
Provide updated charts.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Provided new, updated charts.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 April 2017
Resolved
Provide missing components of first-aid kit.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Provided missing components.
Fire Fighting › Fire Bucket › Availability
Issued 26 April 2017
Resolved
Pfovide three marked fire buckets.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Fire buckets present.
Engineering › Fuel Oil Service System › Valve, Control
Issued 26 April 2017
Resolved
Mark emergency fuel cut off valves at activation point on deck.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Fuel valves marked.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 26 April 2017
Resolved
Fix/replace engine jacket temp gauge.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: New gauge installed.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 26 April 2017
Resolved
Stencil vessel name on all lifejackets.
Action required: 705 - Other - as specified
Resolved 26 April 2017
Resolution: Cleared prior to departure.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 April 2017
Resolved
Add retro-reflective material to stbd lifering.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Added tape.
Lifesaving › Lifebuoys › Serviceable
Issued 12 July 2016
Resolved
Replace ring buoy.
Condition: Damaged By Earlier Event
Due 27 July 2016
Resolved 20 October 2016
Resolution: Owner provided a new ring buoy for the vessel.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 12 July 2016
Resolved
Replace light batteries.
Condition: Damaged By Earlier Event
Due 27 July 2016
Resolved 20 October 2016
Resolution: Vessel owner purchased new batteries for the floating waterlight.
Engineering › Bilge Water Management System › Strainer
Issued 12 July 2016
Resolved
Install strainer basket for aft cabin bilge suction.
Due 13 August 2016
Resolved 20 October 2016
Resolution: Owner installed a new strainer basket for aft cabin bilge suction.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 19 July 2011
Resolved
Provide proof of compliance with DAPI program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2012
Resolution: Vessel has all proper DAPI documentation and enrollment certificates
Stability › Watertight Integrity › General
Issued 19 July 2011
Resolved
Repair in kind holes in fwd cabin space and galley (stbd side.)
Due 16 August 2011
Resolved 29 July 2011
Resolution: Holes were properly repaired.
Construction/Loadline › Hull › Weld
Issued 19 July 2011
Resolved
Replace chain port side fwd shrouds b/w chainplates and turnbuckles as discussed.
Action required: 705 - Other - as specified
Due 16 August 2011
Resolved 29 July 2011
Resolution: Chains were replaced.
Lifesaving › Lifefloat › Serviceable
Issued 19 July 2011
Resolved
Conduct repairs to life float using manufatures repair kit.
Action required: 705 - Other - as specified
Due 16 August 2011
Resolved 29 July 2011
Resolution: Satisfactory repairs were conducted.
Construction/Loadline › Structures › Superstructure
Issued 19 July 2011
Resolved
Un-stepped mast for CG visual inspection at next Dry Dock
Action required: 705 - Other - as specified
Due 31 March 2012
Resolved 30 March 2012
Resolution: Attended vessel at Tottenville Dry Dock to visually inspect both the un-stepped main mast and forward mast. The main mast port side futtocks shroud was replaced in-kind. Both masts are in satisfactory condition.
Engineering › Diesel Engine (propulsion-direct drive) › Crankshaft
Issued 19 May 2008
Resolved
Replace transmission cable. **PTCP**
Action required: 705 - Other - as specified
Resolved 20 May 2008
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 19 May 2008
Resolved
Replace lagging gear for engine exhaust in steering gear box.
Action required: 705 - Other - as specified
Due 2 June 2008
Resolved 5 June 2008
Resolution: Received fax from vessel rep that additional lagging gear has been installed and is secured with lock wire and hose clamps.
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 19 May 2008
Resolved
Provide cleat for starboard quarter side of vessel.
Action required: 705 - Other - as specified
Due 2 June 2008
Resolved 5 June 2008
Resolution: Received fax from vessel rep that a cleat was fitted to the starboard rail in the corresponding location.
Engineering › Bilge Water Management System › Pump
Issued 19 May 2008
Resolved
Provide successful operation of bilge pumps. **PTCP**
Action required: 705 - Other - as specified
Resolved 20 May 2008
Engineering › Fuel Oil Service System › Valve
Issued 19 May 2008
Resolved
Provide successful operation of port side fuel shut-off valve from outside the space. **PTCP**
Action required: 705 - Other - as specified
Resolved 20 May 2008
Fire Fighting › Fire Hoses › Connections
Issued 19 May 2008
Resolved
Provide nozzle for fire hose.
Action required: 705 - Other - as specified
Due 2 June 2008
Resolved 5 June 2008
Resolution: Received fax from vessel rep that a fire nozzle was purchased and is installed.
Deck/Cargo › Holds/Tanks › Hatch
Issued 31 January 2008
Resolved
Provide for proper closure of fwd emergency hatch.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 19 May 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 31 January 2008
Resolved
Replace fwd cable IWO port side deck raining (attachments).
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 19 May 2008
Construction/Loadline › Structures › Trunk
Issued 31 January 2008
Resolved
Provide for mast survey inspection. Provide copy to USCG.
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 19 May 2008
Navigation › Piloting/Steering › Magnetic Compass
Issued 26 April 2007
Resolved
Prove proper operation of magnetic compass light. Vessel is restricted to daylight operation only until complete.
Action required: 705 - Other - as specified
Due 26 May 2007
Resolved 1 May 2007
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 26 April 2007
Resolved
Make repairs to five adult life jackets as indicated by Marine Inspector. Vessel is restricted to the carriage of 45 passengers and 4 crew for a total of 49 total persons until complete.
Action required: 705 - Other - as specified
Due 26 May 2007
Resolved 1 May 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 April 2007
Resolved
Remove dead end wiring coiled on overhead in amidships space.
Action required: 705 - Other - as specified
Due 26 May 2007
Resolved 1 May 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 April 2007
Resolved
Secure all wiring in amidships space with metallic clips every 24 inches.
Action required: 705 - Other - as specified
Due 26 May 2007
Resolved 1 May 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 26 April 2007
Resolved
Permanently mount junction boxes located in amedships space, port side.
Action required: 705 - Other - as specified
Due 26 May 2007
Resolved 1 May 2007
Lifesaving › Lifefloat › Serviceable
Issued 7 August 2006
Resolved
Make repairs to tears/holes in life float in accordance with manufacturer's instructions.
Action required: 705 - Other - as specified
Due 14 August 2006
Resolved 7 August 2006
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 7 August 2006
Resolved
Make permanent repair to broken gear cable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 September 2006
Resolution: Gear cable replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 August 2006
Resolved
Place wire splices in forward compartment in an enclosure.
Action required: 705 - Other - as specified
Due 14 August 2006
Resolved 18 September 2006
Resolution: Splices were placed in junction boxes.
Stability › Watertight Integrity › General
Issued 7 August 2006
Resolved
Install a lanyard/securing device on forepeak hatch.
Action required: 705 - Other - as specified
Due 14 August 2006
Resolved 18 September 2006
Resolution: Lanyard installed on hatch.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 26 April 2005
Resolved
Replace line on waterlight lanyard.
Due 3 May 2005
Resolved 10 May 2005
Resolution: Viewed new line on waterlight lanyard.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 26 April 2005
Resolved
Properly stow/separate adult and child lifejackets.
Due 3 May 2005
Resolved 10 May 2005
Resolution: Child and adult lifejackets were seperated and properly stowed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 April 2005
Resolved
Replace/update first aid kit with a Coast Guard approved model, or a kit with equivalent contents.
Due 3 May 2005
Resolved 10 May 2005
Resolution: First aid kit was updated with equivalent contents.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 26 July 2004
Resolved
Provide procedures for leaving passenger count ashore as required by 46 CFR 185.504.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2004
Resolved 26 July 2004
Resolution: Received e-mail copy of procedures for leaving passenger count ashore meeting 46 CFR 185.504.
Documentation › Certificates/Documents › FCC SSL
Issued 26 July 2004
Resolved
Provide documentation of FCC Marine Radio Operator Permit. Vsl is resticted to less than 1000 ft from shore until corrected.
Due 21 August 2004
Resolved 21 August 2004
Resolution: Received fax copy of valid FCC Marine Radio Operator Permit.
Electrical › Lighting (service) › Outlet Box
Issued 26 July 2004
Resolved
Install electrical wiring IVO of galley inside a junction box.
Due 9 August 2004
Resolved 6 August 2004
Resolution: Done
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 26 July 2004
Resolved
Provide proof of annual service for the fixed fire extinguishing system
Due 9 August 2004
Resolved 6 August 2004
Resolution: Received copy of servicing report.
Electrical › Lighting (service) › Lighting Fixture
Issued 26 July 2004
Resolved
Properly install/secure light fixture in pilot house IWO port bunk.
Due 9 August 2004
Resolved 6 August 2004
Resolution: Done.
Documentation › Markings/Placards
Issued 9 June 2003
Resolved
Install vessel's name on port and starboard bow as required by 46 CFR 67.123(a). LEGACY COMPONENT DESC: Vessel name
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 16 June 2003
Resolution: Captain sent digital photos of correction as requested.
Fire Fighting › Emergency Fire Pumps
Issued 9 June 2003
Resolved
Address small leak on P.T.O. fire pump. LEGACY COMPONENT DESC: Leak
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 16 June 2003
Resolution: Captain sent digital photos of correction as requested. A heli-coil was inserted in housing and a replacement screw fastened face plate to specs as designed. Leak secured.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 June 2003
Resolved
Address stray current on electrical bow in fwd work space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 16 June 2003
Resolution: Stray current was from shore tie. A floating ground allowed an inductive connection between ground and hot leads. No remaining stray current detected..
Engineering › Bilge Water Management System › Hose
Issued 9 June 2003
Resolved
Double clamp vital system hoses (raw water).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 16 June 2003
Resolution: Received e-mail statement from the vessel''s Master claiming that additional clamps have been placed on the raw water cooling hoses for the MDE.
Electrical › Electric Generation Source (emergency)
Issued 9 June 2003
Resolved
Provide & install covers for batteries. LEGACY COMPONENT DESC: Battery Covers
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 16 June 2003
Resolution: Vessel''s Master provided an e-mail statement indicating that the battery covers were located and reinstalled as required.
Navigation › Piloting/Steering
Issued 19 March 2002
Resolved
Provide vessel with Coast Guard or equivalent Light List. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Unknown
Due 16 May 2002
Resolved 20 May 2002
Resolution: CG light list provided.
Accommodation/Occupational Safety › Medical/First Aid
Issued 19 March 2002
Resolved
Replace expired medications and provide eye wash for first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 16 May 2002
Resolved 20 May 2002
Resolution: Expired meds replaced and eye wash provided.
Unknown
Issued 25 May 2001
Resolved
Repair glass in port window on port side CAPT cabin.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Navigation
Issued 25 May 2001
Resolved
Nav light on port side is not operating. Prove proper operation.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Navigation
Issued 25 May 2001
Resolved
Replace broken emergency steering cable.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Lifesaving
Issued 25 May 2001
Resolved
Provide 2 paddles for Life Float.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Documentation
Issued 25 May 2001
Resolved
Provide Employee policy for drug/alcohol program and supervisor 60 minute training.
Condition: Unknown
Due 10 June 2001
Resolved 9 July 2001
Engineering
Issued 25 May 2001
Resolved
Repair exhaust water jacket leak prior to carrying passengers.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Engineering
Issued 28 August 2000
Resolved
INSTALL FLAME IMPINGEMENT BOWL ON RACOR FUEL FILTER.
Condition: Unknown
Due 28 August 2000
Resolved 28 August 2000
Lifesaving
Issued 20 June 2000
Resolved
PROVIDE PASSENGER COUNT TO DOCKSIDE PERSONNEL FOR EACH VOYAGE.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Lifesaving
Issued 20 June 2000
Resolved
ATTACH RING BUOY WATERLIGHT TO RING BUOY WITH A METAL CLIP.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Fire Fighting
Issued 20 June 2000
Resolved
EITHER MEET 46 CFR 181.400(B)(5) BY PROVIDING ADEQUATE AMOUNT OF CO2 W/ APPLICATOR GOING DIRECTLY TO ENGINEROOM & ENCLOSING DECK ABOVE ENGINEROOM, OR SUBMIT PLANS TO INSTALL PROPER FIXED FIREFIGHTING SYSTEM FOR VOLUME OF ENGINE & ACCOMS SPACE.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Lifesaving
Issued 20 June 2000
Resolved
PROVIDE WIRE SPLINT FOR FIRST AID KIT.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Accommodation/Occupational Safety
Issued 20 June 2000
Resolved
RESOLVE OUTSTANDING MSD PLAN APPROVAL ISSUES.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Documentation
Issued 20 June 2000
Resolved
LOG CREW TRAINING & SURVIVAL CRAFT INSPECTIONS.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Accommodation/Occupational Safety
Issued 4 May 2000
Resolved
SHOW PROPER OPERATION OF NEWLY INSTALLED MSD HOLDING TANK TO COAST GUARD MARINE INSPECTOR IN ACCORDANCE WITH PLAN REVIEW LETTER DATED 18 AUGUST 2000.
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Engineering
Issued 14 April 2000
Resolved
Prove proper operation of main diesel engine and reduction gear installation.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Construction/Loadline
Issued 14 April 2000
Resolved
Repair/renew port side fwd cabin portlight.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Construction/Loadline
Issued 14 April 2000
Resolved
Have rigging repairs inspected by a USCG Marine Inspector.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Accommodation/Occupational Safety
Issued 14 April 2000
Resolved
Submit plans for installation approval of MSD holding tank.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Accommodation/Occupational Safety
Issued 14 April 2000
Resolved
Prove proper installation of MSD.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Engineering
Issued 14 April 2000
Resolved
Install lagging on exhaust pipe IWO steering gear.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Construction/Loadline
Issued 14 April 2000
Resolved
Repair/renew stbd aft portlight on stbd fwd cabin.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Fire Fighting
Issued 14 April 2000
Resolved
Remove all wood paneling IWO wood buring stove, and install metal flashing IWO stove area.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Engineering
Issued 2 March 2000
Resolved
COMPLETE AS-BUILT VERIFICATION OF FUEL TANK DRAIN MODIFICAITON, IAW ACTNY PR-010031.
Condition: Unknown
Due 2 March 2000
Resolved 2 March 2000
Engineering
Issued 25 February 2000
Resolved
SHOW PROPER INSTALLATION AND OPERATION OF NEW PROPULSION ENGINE
Condition: Unknown
Due 25 February 2000
Resolved 25 February 2000
Documentation
Issued 12 May 1999
Resolved
Submit plans for review and approval for the installation of fixed fire fighting systems in the machinery space iaw 46 CFR 181.115(b) and 46 CFR 181.400. Vessel is not to operate with passengers for hire after 01 Jul 99unless plans are submitted.
Condition: Unknown
Due 1 July 1999
Resolved 2 August 1999
Fire Fighting
Issued 12 May 1999
Resolved
INSTALL AN ADDITIONAL B-II PORTABLE FIRE EXTINGUISHER FOR THE ENGINE ENCLOSURE IN ACCORDANCE WITH 46 CFR 181.400(b)(5)(i) through (iii), AND RELOCATE EXISTING B-II EXTINGUISHER AT THE EXIT FROM THE ENGINE/CREW BERTHING COMPARTMENT.
Condition: Unknown
Due 12 May 1999
Resolved 12 May 1999
Fire Fighting
Issued 12 May 1999
Resolved
Install fixed fire fighting systems in vessels machinery space iaw USCG approved plans. Vessel is not to operate with passengers for hire after 01Aug 99 unless the required fixed fire fighting systems have been installed and operated to the satisfaction of an attending marine inspector.
Condition: Unknown
Due 1 August 1999
Resolved 2 August 1999
Lifesaving
Issued 15 May 1998
Resolved
Provide weak link for bouyant apparatus and properly install.
Condition: Unknown
Due 15 May 1998
Resolved 15 May 1998
Construction/Loadline
Issued 16 October 1997
Resolved
Provide copy of audiogauging report.
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Engineering
Issued 16 October 1997
Resolved
Install and prove proper operation, (no leaks) of engine exhaust jacket cooler.
Condition: Unknown
Due 10 February 1998
Resolved 10 February 1998
Engineering
Issued 16 October 1997
Resolved
Clean port and starboard fuel tanks where fuel is showing. Call Coast Guard inspector to reexamine in 2 months.
Condition: Unknown
Due 10 February 1998
Resolved 10 February 1998
Lifesaving
Issued 13 May 1996
Resolved
DISTRESS SIGNAL BOX MUST BE BRIGHTLY COLORED AND PROPERLY MARKED
Condition: Unknown
Due 20 May 1996
Resolved 24 May 1996
Lifesaving
Issued 13 May 1996
Resolved
LIFEJACKET STORAGE BOXES MUST BE SECURED TO THE DECK
Condition: Unknown
Due 20 May 1996
Resolved 24 May 1996
Lifesaving
Issued 13 May 1996
Resolved
PLACE RETRO-REFLECTIVE TAPE ON BOTH RING BUOYS
Condition: Unknown
Due 20 May 1996
Resolved 24 May 1996
Engineering
Issued 13 May 1996
Resolved
REPLACE FLAME SCREEN ON FUEL VENT
Condition: Unknown
Due 20 May 1996
Resolved 24 May 1996
Lifesaving
Issued 13 May 1996
Resolved
PASSENGER CARRYING CAPACITY REDUCED TO 54 UNTIL 3 ADDITIONAL LIFEJACKETS ARE OBTAINED.
Condition: Unknown
Due 20 May 1996
Resolved 24 May 1996
Lifesaving
Issued 13 May 1996
Resolved
DONNING INSTRUCTIONS FOR EACH TYPE LIFEJACKET USED ON BOARD MUST BE POSTED
Condition: Unknown
Due 20 May 1996
Resolved 24 May 1996
Construction/Loadline
Issued 6 March 1991
Resolved
PROVIDE AS "RE-BUILT" SCANTLINGS FOR REVIEW AND COMPARISON WITH PREVIOUS HULL GAUGING REPORT TO DETERMINE ACCEPTABILITY OF STERN AREA BOTTOM AND SIDE PLATING. INSERT OR RENEW PLATING AS NEEDED .
Condition: Unknown
Due 6 March 1991
Resolved 6 March 1991
Fire Fighting
Issued 20 April 1990
Resolved
REPLACE OR REPAIR INSULATION LOCATED BEHIND GALLEY WOOD STOVE.
Condition: Unknown
Due 20 April 1990
Resolved 20 April 1990
Deck/Cargo
Issued 20 April 1990
Resolved
INSTALL FLAME SCREEN'S FOR P&S F/O VENT LINE AND 1" VENT F/O LINE LOCATED JUST FORWARD OF ENGINE ROOM HOUSE ON MAIN DECK.
Condition: Unknown
Due 20 April 1990
Resolved 20 April 1990
Construction/Loadline
Issued 20 April 1990
Resolved
MAKE WATERTIGHT; COLLISION BULKHEAD AND FORWARD ENGINE ROOM BULKHEAD, IN WAY OF WIRE RUNS.
Condition: Unknown
Due 20 April 1990
Resolved 20 April 1990
Lifesaving
Issued 15 May 1989
Resolved
REPLACE GRAB LINES ON ALL 3 LIFE RINGS.
Condition: Unknown
Due 15 May 1989
Resolved 15 May 1989
Electrical
Issued 15 May 1989
Resolved
PROPERLY MOUNT SWITCH FOR CENTERBOARD PIN WELL BILGE PUMP.
Condition: Unknown
Due 15 May 1989
Resolved 15 May 1989
Lifesaving
Issued 15 May 1989
Resolved
REPLACE 18 PERSON BOUYANT APPARATUS, PAINTER AND WEAK LINK WITH USCG APPROVED BOUYANT APPARATUS AND WEAK LINK AND PROPER PAINTER.
Condition: Unknown
Due 15 May 1989
Resolved 15 May 1989
Engineering
Issued 18 March 1988
Resolved
INSTALL HIGH AND LOW VENTILATION DUCTS IN ENGINE COMPARTMENT IN ACCORDANCE WITH 46 CFR 182.20-45.
Condition: Unknown
Due 18 March 1988
Resolved 18 March 1988
Engineering
Issued 7 April 1987
Resolved
RENEW FLEXIBLE HOSES FOR PRIMARY BILGE SYSTEM WITH RIGID NON-METALLIC OR METALLIC PIPING.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Engineering
Issued 7 April 1987
Resolved
REPLACE IMPROPER (SOFT CORRUGATED ) DISCHARGE HOSE FOR AUTOMATIC BILGE PUMPIN ENGINE COMPARTMENT.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Engineering
Issued 7 April 1987
Resolved
INSTALL INDICATION FOR AUTOMATIC BILGE PUMP VISIBLE AT OPERATOR'S STATION.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Engineering
Issued 7 April 1987
Resolved
INSTALL HIGH AND LOW VENTILATION DUCTS IN ENGINE COMPARTMENT IN ACCORDANCE WITH 46 CFR 182.20-45.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Engineering
Issued 7 April 1987
Resolved
INSTALL CHECK VALVE AT INTAKE TO AFT BILGE IN FORWARD CABIN AND CLEAN AREASAROUND STRAINER.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Accommodation/Occupational Safety
Issued 7 April 1987
Resolved
PROVIDE APPROVED PLANS FOR SEWAGE HOLDING TANK INSTALLED ON THE VESSEL.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Lifesaving
Issued 25 June 1986
Resolved
PROVIDE A USCG APPROVED WATERLIGHT FOR VESSEL'S BUOYANT APPARATUS, AND PROVE PROPER OPERATION OF SAME,IN ACCORDANCE WITH 46 CFR 180.15-1.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Navigation
Issued 25 June 1986
Resolved
REPLACE OR REPAIR VESSEL'S MASTHEAD LIGHT, PRESENTLY HELD TOGETHER WITH ELECTRICAL TAPE(FOREMAST).
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Electrical
Issued 25 June 1986
Resolved
REMOVE SPLICE IN WIRING OF AUTOMATIC BILGE PUMP LOCATED UNDER FORWARD END OF MAIN ENGINE WHERE SPLICE IS AT OR BELOW NORMAL BILGE WATER LEVEL.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Navigation
Issued 25 June 1986
Resolved
PROPERLY SECURE ELECTRICAL WIRING TO THE VESSEL'S MASTHEAD LIGHT AND RADIO ANTENNA PRESENTLY ATTACHED TO SHROUDS WITH ELECTRICAL TAPE.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Fire Fighting
Issued 25 June 1986
Resolved
PROPERLY SECURE, WITH APPROPRIATE BRACKETS, THE PORTABLE FIRE EXTINGUISHERSAT THE FOLLOWING LOCATIONS: 1)ENGINE ROOM STARBOARD SIDE; 2)BASE OF MAIN- MAST.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Engineering
Issued 25 June 1986
Resolved
PROPERLY SECURE MECHANICAL LUBE OIL PRESSURE GUAGE ON VESSEL'S MAIN ENGINE.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Electrical
Issued 25 June 1986
Resolved
PROVIDE A PERMANENT SHORE TIE CONNECTION RECEPTACLE FOR INCOMING 110 VOLT AC IN ACCORDANCE WITH 46 CFR 183.10-50.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Electrical
Issued 25 June 1986
Resolved
PROVIDE SUITABLE GLOBES AND GUARDS WHERE MISSING ON LIGHT FIXTURES AT THE FOLLOWING LOCATIONS: ENGINE ROOM LAZARETTE;ACCOMMODATIONS AFT PORT SIDE; ACCOMMODATIONS AMIDSHIPS PORT SIDE;FORWARD BULKHEAD AT GALLEY.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Engineering
Issued 25 June 1986
Resolved
PROVE PROPER OPERATION OF REMOTE F/O SHUT-OFF STARBOARD, PRESENTLY NOT CLOSING COMPLETELY.(IE FULL 90 DEGREE SHUT-OFF)
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Electrical
Issued 25 June 1986
Resolved
REMOVE OR INSTALL IN A JUNCTION BOX "DEAD WIRES" AT THE FOLLOWING LOCATIONSA)WIRING ASSOCIATED W/DEPTH FINDER LOCATED PORT FWD IN E/R;B)WIRING TO MAINENGINE ELECTRICL L/O PRESURE SWITCH LOCATED FWD BHD OF E/R;C)3-WIRE CONDUC-TOR LOCATED UNDER COMPASS SHELF;D)LOOSE CABLE LOCATED OVER BERTH PORT ACCOM
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Electrical
Issued 25 June 1986
Resolved
ENSURE THAT SPLICING IS IN ACCORDANCE WITH 46 CFR 183.05-50(B) AT THE FOLLOWING LOCATIONS:A)WIRING ASSOCIATED WITH VESSEL'S RADIO EQUIPMENT WHERESPLICED-E/R PORT SIDE;B)IN WAY OF SPLICES MADE IN WIRING TO VESSEL'S NON- REQUIRED AUTOMATIC BILGE PUMPS.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986