Records from 2007 to 2026. Most recent: inspection, 7 April 2026.
Inspection history · 21
7 April 2026
Damage Survey · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8344184
27 August 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8218704
9 December 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8044916
11 August 2024
Annual Inspection · Administrative Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7979097
14 September 2023
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7791505
30 March 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7663349
26 August 2022
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7544203
12 August 2021
COI Inspection · Internal Structural Exam · Administrative Inspection · Inclining Experiment · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7279117
25 October 2019
Internal Structural Exam · Drydock Exam · Plan Review "T" Boat
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7281395
23 July 2019
Annual Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6759297
6 June 2019
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6705203
9 April 2019
Drydock Extension · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6760789
16 July 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6480989
8 July 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6477039
7 July 2018
Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6472815
25 April 2017
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6132362
19 April 2017
Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6128429
13 March 2017
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6106823
13 March 2017
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6113680
12 July 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5937719
29 March 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5842841
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 April 2026
Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. While moored, vessel experienced an allision with the M/V CIRCLE LINE BROOKLYN causing minor damage to the jib-boom. Make appropriate repairs to boom and its metal cap.
46 CFR 177.330
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 13 April 2026
Resolution: Received and reviewed documenting proper repairs to jib-boom and cap.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2024
Resolved
MAIN ENGINE REMOTE FUEL SHUT-OFF VALVES MUST OPERATE TO SECURE THE SUPPLY FLOW OF FUEL FROM THE STORAGE TANKS TO ENGINES. BOTH PORT & STBD FUEL SHUT-OFF PULL CABLES WERE OBSERVED TO NOT FULLY CLOSE SUPPLY VALVES. ADJUST / REPAIR / REPLACE TO [name withheld].
46 CFR 455(b)(4)
46 CFR 187.20-40(b)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2024
Resolution: Rcvd sat evidence of def correction, properly operating fuel ROV.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 August 2024
Resolved
OVERCURRENT ELECTRICAL PROTECTION COMPONENTS MUST BE OF CARTRIDGE OR BREAKER TYPE. IN-LINE BLADE (AUTOMOTIVE STYLE) FUSES ARE NOT PERMITTED. ENGINE ROOM 12V BREAKER PANEL FOR BILGE ALARMS & VHF RADIO WAS FOUND TO HAVE BLADE STYLE FUSE. REPLACE / RENEW WITH REQUIRED STYLE OVER-CURRENT PROTECTION TO USCG [name withheld] 30 DAYS.
NOTE: IF ALTERING / MODIFYING ELECTRICAL SYSTEM, NOTIFY OCMI OFFICE TO ENSURE PROPER PLAN REVIEW AND OVERSIGHT.
46 CFR 183.350
46 CFR 183.10-35 (-40)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 October 2024
Resolution: Rcvd sat evidence of proper fuse replacement.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 26 August 2022
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level alarm. MI discovered that the visual/audible alarm was located in the engine space and not at the operating space. Deficiency will be rectified prior to next drydock (June 2023)
Action required: 705 - Other - as specified
Resolved 14 September 2023
Resolution: Vessel installed a high water alarm panel at the operating station. Verified the alarms during annual inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 August 2022
Resolved
The design, material, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. MI discovered missing rigging components. Operator & crew shall visually inspect/replace all missing rigging components.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 September 2022
Resolution: Received photographs (see documents) of secured rigging components. Operator used "nyloc" lock nuts to secure all rigging components.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 August 2021
Resolved
Each floating waterlight must be attached by a lanyard.
Lanyard on port ring buoy is beginning to fray and requires replacement/repair.
46CFR180.71(d)
50C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 September 2021
Resolution: Received documentation attesting to rectification of deficiency.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 July 2019
Resolved
A VESSEL SHALL BE FITTED WITH A VISUAL AND AUDIBLE HIGH WATER ALARM IN ANY SPACE THAT IS SERVED BY A NON-WATERTIGHT HATCH. THE BILGE ALARM FOR THE MIDSHIPS BILGE DID NOT PROPERLY ILLUMINATE WEHN THE ALARM WAS ACTIVATED.
46CFR182.530(a)(3)
46CFR182.115(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 6 August 2019
Resolution: Cleared by [name withheld].
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 23 July 2019
Resolved
VESSELS AND THEIR EQUIPMENT SHALL BE MAINTAINED IN ACCORDANCE WITH GOOD MARINE PRACTICES. THE HIGH BILGE WATER ALARM FLOAT SWITCH WAS NOT SECURED IN ITS POSITION AND FREELY MOVED WITHIN THE BILGE.
46CFR176.25-50(a) "OLD T"
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 6 August 2019
Resolution: Cleared by [name withheld].
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2019
Resolved
ELECTRICAL INSTALLATIONS SHALL BE MADE IN A MANNER TO PROTECT THE CREW, PASSENGERS, AND SHIP FROM HAZARDS. THERE WAS A JUNCTION BOX AND AN OUTLET BOX THAT WERE NOT PROPERLY MOUNTED AND WERE ALLOWED TO SWING FREELY IN THE FORWARD STARBOARD PORTION OF THE MIDSHIPS VOID.
46CFR183.200
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 6 August 2019
Resolution: Cleared by [name withheld].
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 July 2019
Resolved
EACH SURVIVAL CRAFT SHALL BE MAINTAINED IN AN OPERATIONAL READY CONDITION, HAVING MAINTENANCE CONDUCTED IN ACCORDANCE WITH MANUFACRTURER'S REQUIREMENTS. VESSEL'S LIFE FLOAT HAD SEVERAL AREAS WHERE THE COATING WAS TORN, AS WELL AS MULTIPLE REPAIRS
THAT WERE PREVIOUSLY MADE. REPAIR IAW MANUFACT REQS.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 6 August 2019
Resolution: Cleared by [name withheld].
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2019
Resolved
Operator voluntarily placed vessel out of service until repair work can be completed for faulty engine block. Operator must submit engine repair/replacement proposals for review.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2022
Resolution: approved inspection recieved
Navigation › Piloting/Steering › Marine Charts
Issued 26 April 2017
Resolved
Provide updated charts.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Provided new, updated charts.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 April 2017
Resolved
Provide missing components of first-aid kit.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Provided missing components.
Fire Fighting › Fire Bucket › Availability
Issued 26 April 2017
Resolved
Pfovide three marked fire buckets.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Fire buckets present.
Engineering › Fuel Oil Service System › Valve, Control
Issued 26 April 2017
Resolved
Mark emergency fuel cut off valves at activation point on deck.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Fuel valves marked.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 26 April 2017
Resolved
Fix/replace engine jacket temp gauge.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: New gauge installed.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 26 April 2017
Resolved
Stencil vessel name on all lifejackets.
Action required: 705 - Other - as specified
Resolved 26 April 2017
Resolution: Cleared prior to departure.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 April 2017
Resolved
Add retro-reflective material to stbd lifering.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Added tape.
Lifesaving › Lifebuoys › Serviceable
Issued 12 July 2016
Resolved
Replace ring buoy.
Condition: Damaged By Earlier Event
Due 27 July 2016
Resolved 20 October 2016
Resolution: Owner provided a new ring buoy for the vessel.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 12 July 2016
Resolved
Replace light batteries.
Condition: Damaged By Earlier Event
Due 27 July 2016
Resolved 20 October 2016
Resolution: Vessel owner purchased new batteries for the floating waterlight.
Engineering › Bilge Water Management System › Strainer
Issued 12 July 2016
Resolved
Install strainer basket for aft cabin bilge suction.
Due 13 August 2016
Resolved 20 October 2016