ST MARYS CHALLENGER

Built
1906
Last inspected
1 June 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 1 June 2026
…with no type recorded49
Operational controls None recorded without a removal date
Years with a record 43 calendar years (1984–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

5009984
WDB9135
Flag
UNITED STATES
Tonnage
5136 - Regulatory (Subpart C or D), Net Ton 0 - Dead Weight, Ton 5136 - Regulatory (Subpart C or D), Gross Ton
Maury page id
psix-41704
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

PRENTISS BROWN Towing Vessel · MISLE 94641 · 24 July 2023 · activity 7762613PRENTISS BROWN Towing Vessel · MISLE 94641 · 14 April 2020 · activity 6938908

Inspection history · 185

1 June 2026 Annual Inspection · Vessel Attendance · Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam · Plan Review (Other than "T")
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8385954
5 January 2026 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8290289
22 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8191744
22 July 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8193157
9 April 2025 In-Service Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8109784
11 March 2025 Drydock Extension
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8112452
21 October 2024 Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 8022081
25 April 2024 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7901138
4 March 2024 COI Inspection · In-Service Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7875383
24 July 2023 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7762613
18 May 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7691198
16 October 2022 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7578810
23 June 2022 Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7482774
17 December 2021 Damage Survey
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7378505
24 June 2021 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7235820
15 September 2020 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7059210
30 July 2020 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7026433
29 May 2020 Drydock Exam · Annual Inspection · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6963466
15 May 2020 Examination of Repairs
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6956682
14 April 2020 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6938908
7 January 2020 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6884529
29 March 2019 COI Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6646302
15 February 2019 Internal Structural Exam · Administrative Inspection · Drydock Extension
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6626551
16 March 2018 Annual Inspection · MTSA Verification · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6374301
5 February 2018 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6563352
30 January 2018 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6370606
27 March 2017 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6112108
20 March 2017 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6108654
7 March 2017 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6101003
21 February 2017 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6091684
18 August 2016 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5976314
26 July 2016 Damage Survey
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5960887
16 June 2016 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5913300
1 April 2016 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5847993
5 June 2015 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5148282
20 April 2015 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5107013
20 April 2015 Deficiency Check
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5107108
23 March 2015 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5089335
19 March 2015 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5087241
16 March 2015 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5084561
27 August 2014 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4968140
4 August 2014 MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4943741
31 July 2014 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4940121
1 July 2014 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4906978
1 July 2014 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4908111
30 June 2014 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4905847
18 March 2014 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4818271
20 November 2013 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4758972
5 September 2013 Drydock Exam · COI Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4707178
14 August 2013 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4685090
12 August 2013 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4683515
11 August 2013 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4682637
10 June 2013 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4616013
13 December 2012 In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4502238
25 June 2012 Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4357351
9 June 2012 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4340453
31 May 2012 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4333535
28 May 2012 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4326045
9 April 2012 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4282920
23 January 2012 DAPI Audit · In-Service Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4230631
13 November 2011 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4187524
14 July 2011 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4089317
6 December 2010 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3908205
16 August 2010 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3826464
6 August 2010 Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3816597
2 August 2010 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3813092
25 June 2010 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3799948
21 May 2010 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3745892
17 May 2010 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3740184
1 April 2010 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3707869
13 April 2009 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3451783
27 March 2009 Annual Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3441506
20 March 2009 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3434926
24 February 2009 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3422858
23 February 2009 Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3423879
11 September 2008 Drydock Extension
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3322605
17 June 2008 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 3240434
13 March 2008 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3158951
13 March 2008 In-Service Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3164540
4 February 2008 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3141752
19 July 2007 In-Service Inspection · Damage Survey
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3000723
4 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2930822
19 March 2007 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2889194
8 January 2007 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2852484
13 December 2006 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2840871
28 February 2006 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2593284
15 February 2006 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2585922
10 November 2005 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2615815
19 September 2005 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2496411
16 June 2005 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2284016
12 April 2004 Periodic Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 2042159
23 February 2004 In-Service Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 2011656
23 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979680
26 June 2003 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1827738
27 December 2002 Annual Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1722984
10 December 2002 Administrative Inspection
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1716949
3 August 2002 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1657434
25 February 2002 Annual Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1488416
8 February 2002 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1485208
12 September 2001 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1072687
21 August 2001 Damage Survey · Examination of Repairs
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1426649
27 June 2001 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1068227
19 April 2001 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1401456
6 September 2000 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 450925
6 September 2000 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 822855
6 June 2000 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 230370
26 April 2000 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 820923
18 April 2000 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 823688
10 January 2000 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 154579
12 December 1999 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 463811
26 April 1999 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 773267
15 April 1999 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1082626
7 October 1998 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 801090
24 August 1998 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 75531
28 June 1998 Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1383893
16 April 1998 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1126215
23 December 1997 Drydock Extension · Examination of Repairs
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 775079
24 October 1997 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 35667
13 August 1997 Examination of Repairs
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1118863
15 May 1997 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1421340
30 April 1997 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1091741
23 April 1997 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1096834
18 March 1997 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1364328
2 September 1996 Examination of Repairs
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1250035
27 July 1996 Examination of Repairs
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1087151
4 June 1996 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1388037
6 April 1996 Deficiency Check · Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1082363
2 January 1996 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 487412
19 October 1995 Type not recorded
No type recorded · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 529316
11 May 1995 Deficiency Check · Examination of Repairs
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1163873
7 April 1995 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1156896
20 December 1994 Damage Survey
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1434200
19 December 1994 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 167154
2 November 1994 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 667017
8 September 1994 Examination of Repairs
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1175943
18 May 1994 Deficiency Check
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1170553
27 April 1994 Re-Inspection · Examination of Repairs
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1356588
25 April 1994 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 37764
12 April 1994 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 22359
29 March 1994 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1367054
2 November 1993 Administrative
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1156780
17 September 1993 Damage Survey · Examination of Repairs
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1146318
10 September 1993 Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1377045
9 September 1993 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 146022
24 August 1993 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 847646
26 May 1993 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1148296
11 April 1993 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 839328
22 December 1992 Hull Examination
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1432638
4 September 1992 Damage Survey
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1401638
13 March 1992 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1266496
2 October 1991 Examination of Repairs
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1253948
11 July 1991 Type not recorded
No type recorded · Commandant (CG-INV) · Activity 231443
7 April 1991 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 924954
8 March 1991 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1228140
11 April 1990 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1230183
3 April 1990 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 987685
6 March 1990 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1209385
14 April 1989 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1338015
7 April 1989 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1044319
18 March 1989 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 894702
30 December 1988 Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1037694
12 August 1988 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1207891
4 July 1988 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 895262
30 June 1988 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1208156
9 May 1988 Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1347786
12 April 1988 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1036160
20 March 1988 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 992973
20 January 1988 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1328493
11 January 1988 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1319573
29 May 1987 Administrative
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1334734
10 April 1987 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1330629
23 March 1987 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1017682
11 March 1987 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1012201
9 March 1987 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1013270
27 February 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1313129
8 April 1986 Deficiency Check
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1306001
21 March 1986 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 998055
13 February 1986 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1292531
3 June 1985 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1293683
28 March 1985 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1288646
21 March 1985 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1288616
20 March 1985 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 980502
11 March 1985 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1286620
26 December 1984 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1284886
4 January 1984 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 976110

Deficiency record · 137

11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 15 July 2026 Resolved
Identified 01 immersion suits that was wasted. Each vessel must carry immersion suits of suitable size for each person on board. Renewed with spare.
Action required: 10 - Deficiency Rectified
Resolved 15 July 2026
Resolution: Renewed with spare.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 July 2026 No resolution recorded
Existing structure previously approved will be considered satisfactory so long as it is maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection. Prior to and during winter lay-up 2026/2027, Port City Marine Services must complete all required benchmarks and repairs to the starboard side upper rivet lapped seam as outlined in the July 8, 2026 letter from MSU Sturgeon Bay. Cite: 46 CFR 92.01-90
Action required: 705 - Other - as specified
Due 1 March 2027
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 July 2026 No resolution recorded
Existing structure previously approved will be considered satisfactory so long as it is maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection. Prior to and during winter lay-up 2026/2027, Port City Marine Services must complete all required benchmarks and repairs to the port side upper rivet lapped seam as outlined in the July 8, 2026 letter from MSU Sturgeon Bay. Cite: 46 CFR 92.01-90
Action required: 705 - Other - as specified
Due 1 March 2028
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 July 2025 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual and periodic inspections within the periods specified in 91.27-1 (a) and (b) and your Certificate of Inspection must be endorsed. The annual inspection due by 20 June 2025 was not completed and the COI was not endorsed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2025
Resolved 24 July 2025
Resolution: Vessel completed annual inspection in Sturgeon Bay on 23Jul25.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 11 March 2025 Resolved
A cement patch was found on the forward starboard bulkhead of the #1 ballast tank visible from the pump roomcement. Complete permanent repair prior to approval of drydock extension.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 April 2025
Resolved 9 April 2025
Resolution: MSU Toledo verified permanent repairs were made to area where cement box was installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 March 2024 Resolved
Renew Gasket, aft main deck starboard side watertight door.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 April 2024
Resolved 20 March 2024
Resolution: Ships crew corrected twisted gasket.
01 - Certificates & Documentation › 013 - Documents › Fire safety operational booklet
Issued 4 March 2024 Resolved
Revise fire control plan to reflect proper stowage locations of Immersion suits and Type I pfd's.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2024
Resolved 25 April 2024
Resolution: Plan corrected and placed onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 March 2024 Resolved
Install non-conductive mat on back side of the main switchboard and remove cardboard boxes stored in front of back panels.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2024
Resolved 25 April 2024
Resolution: MATT Installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 March 2024 Resolved
Renew Fire Ax in upper generator space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2024
Resolved 25 April 2024
Resolution: Fire Ax provided and placed on station.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 18 May 2023 Resolved
Port engineering to provided 3rd party service reports for; Fire Extinguishers, Cat SSDG’s.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 22 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2023 Resolved
Free up and demo operation of the fwd peak tank reach rod serving the tank suction line valve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 22 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2023 Resolved
Properly dead-end electrical cable in compartment below and under the port fwd anchor windlass.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 23 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2023 Resolved
Renew broken paralleling switch on the main switchboard for the fwd generator.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 23 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2023 Resolved
Where missing, install breaker directory in several electrical panels.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 23 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2023 Resolved
Identify and label electrical disconnect switch located fwd 2nd level by the tunnel WTD.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 23 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 18 May 2023 Resolved
Remove excess cement build up on both fwd ring buoy water lights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 23 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 June 2021 Resolved
Cover broken and missing on aft port side exterior receptacle. Install new cover IAW 46 CFR 111.81-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 June 2021
Resolved 26 June 2021
Resolution: Cover renewed prior to CG MI completing the examination.
01 - Certificates & Documentation › 013 - Documents › Shipboard marine pollution emergency plan for NLS
Issued 26 June 2021 Resolved
COFOR onboard and presented was expired. Present valid COFOR.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 26 June 2021
Resolved 26 June 2021
Resolution: Master looked up and presented documentation reflecting the vessel had a valid COFOR
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 June 2021 Resolved
portable Fire extinguisher in teh forward control room was not services within the last year. Service fire extinguisher iaw 46 CFR 91.25-20 and or replace extinguisher with an extinguisher that has been serviced within the last year.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 June 2021
Resolved 26 June 2021
Resolution: Extinguisher replaced before CG MI's departure. C/E stated extinguisher not serviced would be sent out for servicing.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 26 June 2021 Resolved
Shackle missing from on the lower starboard main deck guardrail cable. Install an adequate shackle in order to support lower guardrail cable iaw 46 CFR 45.115(b).
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 26 June 2021
Resolved 26 June 2021
Resolution: Crewmember installed an proper fastener prior to CG MI's departure.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 June 2021 Resolved
Flat black paint, on the fwd Port and Stbd navigational lights, backing worn. Repaint both backing with flat black paint iaw 33 CFR Part 84
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 June 2021
Resolved 26 June 2021
Resolution: Crew repainted both flat black paint prior to CG MI's departure.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2020 Resolved
Electrical connections on the fwd end stbd side hyrdaulic unit needs to be terminated in a junction box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2020
Resolved 15 September 2020
Resolution: Electrical connections have been satisfactorily repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 May 2020 Resolved
Waterlight on stbd bow was inoperable. Renew waterlight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2020
Resolution: Stbd bow waterlight is operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 May 2020 Resolved
Lifebuoy on port bow has a broken waterlight bracket. Renew bracket.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2020
Resolution: Port bow waterlight bracket was renewed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 May 2020 Resolved
Make permanent repairs to holed bottom plate in #3 port ballast tank in way of temporary cement box patch.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 June 2020
Resolution: Permenent repairs made to the damaged areas.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 May 2020 Resolved
Vessel is experiencing ingress of water into #3 ballast tank from breeched bottom plate. Make tank available for inspection and complete temporary repairs to the satisfaction of the attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2020
Resolved 16 May 2020
Resolution: Temporary repairs effected employing cement box / pipe patch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 March 2019 Resolved
Make air receiver, located in forward pump room, available for internal inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2019
Resolved 14 September 2020
Resolution: Internally inspected air reciever.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 7 March 2017 Resolved
Blank off abandoned fuel line (Black Oil) in the Starboard walking tunnel and stencil no hot work.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 20 March 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 March 2017 Resolved
Renew ring bouy light bracket port forecastle and renew light lines on the port and staboard forecastle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 27 March 2017
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 26 July 2016 Resolved
Provide technician report confirming bow thruster is fully operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2016
Resolution: Technician report provided. Bow thruster pitch controls in the control board, which caused the CP propeller on the thruster to jam in the ‘hard over’ thrust position, were adjusted and system tested to confirm.
Electrical › Electric Supply System (service) › Cable
Issued 1 April 2016 Resolved
Remove all Dead end wires throughout vessel. 46 CFR 111.01-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 21 June 2016
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 1 April 2016 Resolved
Label breaker on switch board as spare. 46 CFR 111.30-15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 21 June 2016
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 1 April 2016 Resolved
Prove proper operation of WTD indicators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 21 June 2016
Stability › Watertight Integrity › General
Issued 1 April 2016 Resolved
STBD port light window needs gasket replaced. 46 CFR 171.116(f)(3)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 21 June 2016
Communications › Alarms/Indicators › General Alarm
Issued 1 April 2016 Resolved
Install placards for general/crew alarms. 46 CFR 113.25-20
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 21 June 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 1 April 2016 Resolved
Repair all existing light fixtures and reinstall all guards.
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 21 June 2016
Electrical › Electrical Distribution System (service) › Panelboard
Issued 1 April 2016 Resolved
Revise electrical one line and load analysis and submit for approval to the Marine Safety Center.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 18 August 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 April 2016 Resolved
Remove all extension cords throughout vessel which are going through Watertight bulkheads, being used as permanent wiring. Properly wire AC in control room, heaters and lighting.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 21 June 2016
Construction/Loadline › Hull › Hull Plating
Issued 5 June 2015 Resolved
Effect repairs to #5 starboard ballast tank and submit repair proposal
Action required: 705 - Other - as specified
Due 5 June 2015
Resolved 22 June 2015
Resolution: Received ABS Report. See Report
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1.1-Documentation Routine Vessel Inspection
Issued 19 March 2015 Resolved
Provide records of compliance with weekly, monthy annual, lay up routine inspections and proof of annual submittal. No records could be produced onboard for this vessel at time of attendance.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 April 2015
Resolved 20 April 2015
Electrical › Lighting (emergency) › Lighting Fixture
Issued 19 March 2015 Resolved
Install emergency light fixtures in the pump room and compressor deck to facilitate egress.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 April 2015
Resolved 20 April 2015
Resolution: New flourescents fitted with battery and ballast backup.
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 March 2015 Resolved
Prior to sailing, prove proper operation of the remote fuel shut off valve for the generator day tank.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2015
Resolved 23 March 2015
Electrical › Electrical Distribution System (service) › Panelboard
Issued 19 March 2015 Resolved
Submit detailed electrical plans the Coast Guard Marine Safety Center (MSC) for approval of the electrical modifications to the bow thruster distribution. (Replacement motor soft start). 46 CFR 91.45-1 and 110.01-3
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 April 2015
Resolved 20 April 2015
Resolution: received email proof of submittal.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 2 June 2014 Resolved
Ship was altered during conversion. Fire plan does not reflect current configuration. Amend fireplan and have it approved by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 1 July 2014
Communications › Internal Communications System › Sound-powered Telephone
Issued 2 June 2014 Resolved
Major conversion grandfather letter for activity 4707178 indicates an agreement between vessel owner and Sector Lake Michigan that there will be comms via sound powered phones between the tug and the barge. Establish and maintain the ability to communicate between vessels via SPP.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 1 July 2014
Deck/Cargo › Cargo Transfer (solid) › General
Issued 2 June 2014 Resolved
Vessel has approved temporary loading manual. Obtain and keep on board an approved permanent loading manual.
Action required: 705 - Other - as specified
Due 1 October 2014
Resolved 2 September 2014
Resolution: Loading manual was reviewed and approved by ABS, dated 29AUG2014. Cleared the requirement.
Stability › Unintentional Flooding › General
Issued 2 June 2014 Resolved
Vessel has a temporary stability letter. Obtain and keep on board an approved permanent stability letter
Action required: 705 - Other - as specified
Due 1 October 2014
Resolved 12 September 2014
Resolution: Per ABS letter 29AUG2014 no stability letter will be issued. In Lieu Load line Cert "This barge shall be operated in accordance with the GUIDANCE MANUAL FOR LOADING, Dwg, No. 801-05, Rev. B, bearing the ABS Americas approval stamp dated 29 August 2014.
Engineering › Steam Boiler (propulsion) › Inner Casing
Issued 11 August 2013 Resolved
Vessel experienced fire Stbd boiler casing / windbox. Prove proper operation of Stbd boiler.
Action required: 705 - Other - as specified
Due 12 August 2013
Resolved 12 August 2013
Engineering › Steam Boiler (propulsion) › Pump
Issued 3 May 2013 Resolved
Use outboard boiler feed pump for emergency purposes only until feed pump overspeed can be proven. 46 CFR 91.25-10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2013
Resolved 5 June 2013
Engineering › Steam Boiler (auxiliary/waste heat) › Tube Sheet
Issued 3 May 2013 Resolved
Effect repairs, and make mounts available for inspection on the Auxiliary boiler. See MISLE Act. 4574064 for details on casualty.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 March 2014
Resolved 18 March 2014
Resolution: Boiler removed as part of converstion project.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 3 May 2013 Resolved
Prove proper operation of all E lights throughout ship and properly mark with Red 1" E per 46 CFR 97.37-25
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2013
Resolved 14 May 2013
Stability › Unintentional Flooding › General
Issued 3 May 2013 Resolved
Effect Perminent repairs to the forward bulkhead of the aft peak tank at next drydocking.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 29 May 2014
Resolution: Aft peak removed during barge conversion.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 3 May 2013 Resolved
HB01- Provide and properly secure a 15lb portable CO2 fire extinguisher in galley.
Action required: 705 - Other - as specified
Due 3 June 2013
Resolved 14 May 2013
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 3 May 2013 Resolved
HB06- Lower and operate port side lifeboat to the satisfaction of attending marine inspector. 46 CFR 199.45(b)(2)
Action required: 705 - Other - as specified
Due 3 June 2013
Resolved 14 May 2013
Electrical › Lighting (service) › Lighting Fixture
Issued 3 May 2013 Resolved
HB05- Cover the exposed overhead light in the oiler/wipers stateroom. 46 CFR 111.75-20
Action required: 705 - Other - as specified
Due 3 June 2013
Resolved 14 May 2013
Electrical › Lighting (service) › Lighting Fixture
Issued 3 May 2013 Resolved
HB04- Repair the rack light for the upper bunk in the #2 deckhand room. 46 CFR 111.75-20
Action required: 705 - Other - as specified
Due 3 June 2013
Resolved 14 May 2013
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 May 2013 Resolved
HB03- Remove or properly terminate dead end wire in the overhead of the first engineer's stateroom. 46 CFR 111.60-17
Action required: 705 - Other - as specified
Due 3 June 2013
Resolved 14 May 2013
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 23 January 2012 Resolved
Perform operational test of lifeboat
Action required: 705 - Other - as specified
Due 15 June 2012
Resolved 31 May 2012
Resolution: Conducted Lifeboat exercise by lowinging LB to water, having crew row LB, raising lifeboat backto cradle.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 23 January 2012 Resolved
Provide new hydrostatic release for EPIRB that expires in May 2012
Action required: 705 - Other - as specified
Due 15 June 2012
Resolved 31 May 2012
Resolution: New Hydrostatic release has been installed.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 23 January 2012 Resolved
Operate No. 2 Gen set and limit paralleling to No. 1 only in an emergency or for maintenence of the No. 2 generator set. The Switchboard must be manned while generators are paralleled until such time that the proper operation of the reverse power relays proper operation can be proven.
Action required: 705 - Other - as specified
Due 1 July 2012
Resolved 9 June 2012
Resolution: Witnessed proper operation of both relays.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 17 May 2010 Resolved
Conduct an port life boat drill.
Action required: 705 - Other - as specified
Due 17 June 2010
Resolved 25 June 2010
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 17 May 2010 Resolved
Install additional electrical recepticles in the Bridge of the vessel and remove outlet multipliers and extension cords next time the vessel is laid up for any reason.
Action required: 705 - Other - as specified
Due 1 September 2010
Resolved 25 June 2010
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 17 May 2010 Resolved
Prove proper operation of the following Unloading generator shutdowns: Overspeed, High Temp and loss of Lube Oil. An additional watchstander must be provided each time the generator is operated.
Action required: 705 - Other - as specified
Due 25 May 2010
Resolved 21 May 2010
Resolution: Overspeed, hi temp and loss of l/o operating properly.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 May 2009 Resolved
Provide a proper electrical connection for the forward sewage booster unit IAW 46 CFR 110.30-7. Currently extension cord plugs are installed to allow the power source to be used as an extension cord.
Condition: Placed in Improper Service
Due 5 June 2009
Resolved 5 May 2009
Resolution: Verified connections were permanent, that the plugs were removed and unit hardwired.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 May 2009 Resolved
Remove temporary wiring (extension cords) and install proper marine ship board cable IAW 46 CFR 111.60-1 if continued service is required at the following locations. Tunnel work bench, engine room heating boiler and engine room test cabinet.
Condition: Placed in Improper Service
Due 5 June 2009
Resolved 17 May 2010
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 4 May 2009 Resolved
Install permanent electrical receptacles for sump pumps used during the winter lay up and the conveyor tunnel as needed IAW 46 CFR 111.79-1. Currently multiple extension cords are used during winter lay up.
Condition: Improper Installation
Due 1 February 2010
Resolved 17 May 2010
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 20 March 2009 Resolved
Upon reconditioning prove proper operation/installation of the Port Generator switchboard bus bar.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 April 2009
Resolved 4 May 2009
Resolution: Verified during Annual inspection.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 20 March 2009 Resolved
Fabricate and install Fire Damper for the Forward Machinery Space Exhaust blower.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 April 2009
Resolved 4 May 2009
Resolution: Verified during Annual Inspection
Electrical › Electrical Distribution System (service) › Panelboard
Issued 20 March 2009 Resolved
Install suitable blanks in the Dunage room panel labeled Fitout/lay up 230 VAC panel.
Action required: 705 - Other - as specified
Due 23 April 2009
Resolved 13 April 2009
Engineering › Steam Boiler (propulsion) › Valve, Relief
Issued 4 February 2008 Resolved
Properly make repairs to the following valves and flanges noted during mounting inspection: Stbd boiler auxiliary feed valve seating surfaces on both flanges needed to be refaced, stbd de-super heater 4" valve needs to be refaced, stbd relief valve flange needs to be refaced. Both port boiler feed water flanges need to be refaced and port main feed water valve needs to be re-faced.
Action required: 705 - Other - as specified
Due 1 March 2008
Resolved 25 February 2008
Engineering › Steam Boiler (propulsion) › Valve, Drum Safety
Issued 19 July 2007 Resolved
Provide a substantial steam safety valve hand relieving arrangements to replace the current bailing or lock wire being used on all steam drum safety valve hand lifting levers. 46 CFR 54.15-1(c).
Condition: Improper Installation
Due 27 July 2007
Resolved 30 July 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 July 2007 Resolved
Weld an insert plate of adequate size in the #1 port ballast tank between the ballast tank bulkhead and the bow thruster space. The existing bulkhead shall be cropped until good steel is found and support framing is utilized for welding of the new insert. All fit-up and final welding is to be examined by the Coast Guard or ABS.
Condition: Unknown
Due 23 July 2007
Resolved 20 July 2007
Resolution: Final Weld inspection was performed by ABS Sturgeon Bay.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 3 April 2006 Resolved
Replace burnt out indicator light on oily water separating system in accordance with 33 CFR 155.380.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 18 April 2006
Deck/Cargo › Cargo Transfer (solid) › General
Issued 3 April 2006 Resolved
Install or fabricate a guard for the unloading auger located in the tunnel
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 18 April 2006
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 15 February 2006 Resolved
Prior to winter lay up conduct testing for automatic auxiliary boiler, boiler is not in use during the working season, in accordance with 46 CFR 61.35.
Action required: 705 - Other - as specified
Resolved 18 April 2006
Resolution: Converted to inspection note.
Lifesaving › Immersion Suits
Issued 15 April 2003 Resolved
Renew retro-reflective tape on 29 immersion suits. LEGACY COMPONENT DESC: Retro-reflective tape
Due 15 April 2003
Resolved 15 April 2003
Resolution: Corrected prior to end of inspection.
Lifesaving › Visual Distress Signals (General)
Issued 15 April 2003 Resolved
Renew waterlight lanyard. LEGACY COMPONENT DESC: Waterlight lanyard
Due 15 April 2003
Resolved 15 April 2003
Resolution: Corrected prior to end of inspection.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 15 April 2003 Resolved
Renew hydrostatic release on after liferaft.
Due 15 April 2003
Resolved 15 April 2003
Resolution: Corrected prior to end of inspection.
Engineering › Pressure Vessel › Relief Valve
Issued 15 April 2003 Resolved
Repair or replace pressure relief valve on cargo engine starting air receiver.
Due 15 April 2003
Resolved 15 April 2003
Resolution: Corrected prior to end of inspection.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 15 April 2003 Resolved
Install non-conducting deck covering in front of emergency swtichboard.
Due 15 April 2003
Resolved 15 April 2003
Resolution: Corrected prior to end of inspection.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 25 February 2002 Resolved
Install 60 second time delay on engine/boiler room CO2 installation. (Existing 25 second time delay inadequate. Performance tested twice. Escape times equalled 29 and 35 seconds respectively)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 March 2002
Resolved 2 May 2002
Resolution: Cleared upon decision by D9(m) that issue would be handled procedurally
Engineering › Steam Boiler (propulsion)
Issued 25 February 2002 Resolved
Replace main oil supply pressure gauge on panel with gauge of proper range (is continually maxed out) LEGACY COMPONENT DESC: Automation Equipment
Due 26 July 2002
Resolved 25 February 2002
Stability › Watertight Integrity
Issued 25 February 2002 Resolved
Make watertight, pipe passages through forward engine room bulkhead in way of side tunnels.
Condition: Improper Installation
Due 26 July 2002
Resolved 3 August 2002
Construction/Loadline › Structures
Issued 25 February 2002 Resolved
Replace missing deadlight covers and dogs LEGACY COMPONENT DESC: Machinery Space Opening
Due 26 July 2002
Resolved 3 August 2002
Engineering › Pressure Vessel
Issued 25 February 2002 Resolved
Provide documentation proving MAWP of potable water head tank. Proper relief valve to be installed and tested, and data plate affixed once value established. Note that while operating pressure is in range of 40-50 psi, system can be exposed to 125 psi control air pressure. LEGACY COMPONENT DESC: Maximum Allowable Working Pressure
Condition: Unknown
Due 26 July 2002
Resolved 3 August 2002
Construction/Loadline › Hull
Issued 8 February 2002 Resolved
Gauge vessel shell plating in way of engine room and submit results to local OCMI office. LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 15 July 2003
Construction/Loadline
Issued 21 August 2001 Resolved
Prior to completing fit-out, 2002, conduct belt guaging on main deck extending from the aft house forward three feet, and supply results of saidguaging to the cognizant OCMI.
Condition: Unknown
Due 1 February 2002
Resolved 15 July 2003
Unknown
Issued 19 April 2001 Resolved
CROP TO GOOD STEEL AND RENEW ANCHOR WINDLASS SUPPORT/DECK BEAM, CHAIN LOCKER, CENTER SUPPORT
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Unknown
Issued 19 April 2001 Resolved
FREE ALL FIRE DAMPERS TO ENSURE PROPER CLOSURE OF DUCT. ENSURE DAMPER LEVER IS MARKED TO INDICATE OPEN AND CLOSED POSITION.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
System not recorded
Issued 19 April 2001 Resolved
INSTALL AUTOMATIC SHUTDOWN ON 500 KW CATERPILLAR GENSET AS PER 46 CFR 111.16-1(C). ENSURE GENERATOR CONTROL SPACE IS MANNED AT ALL TIMES THAT GENERATOR IS IN OPERATION UNTIL DEVICE IS INSTALLED IAW THIS REQUIREMENT.
Condition: Unknown
Due 19 April 2002
Resolved 21 July 2003
Unknown
Issued 19 April 2001 Resolved
SWING SHIP AND UPDATE VSL MAGNETIC COMPASS DEVIATION TABLE
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Unknown
Issued 19 April 2001 Resolved
DEVELOP AND MAINTAIN LIFESAVING EQUIPMENT LOG IAW 46CFR199.190
Condition: Unknown
Due 19 May 2001
Resolved 27 April 2001
Unknown
Issued 19 April 2001 Resolved
RENEW AND POST LEGIBLE COPY OF VESSEL FIRE CONTROL PLAN IAW 46CFR97.36-1
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Unknown
Issued 19 April 2001 Resolved
ADJUST VOLUME OF AUDIBLE ALARM OR MAKE VISUAL ALARM TO INDICATE ENGINE ORDER TELEGRAPH LOSS OF POWER
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Unknown
Issued 19 April 2001 Resolved
LUBRICATE ALL IMMERSION SUIT ZIPPERS SO AS EASILY CLOSED
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Electrical
Issued 18 April 2000 Resolved
MARK I.D. OF POWER AVAILABLE IN ALL CREW QUARTERS. MARK CIRCUIT BREAKER PANEL TO DETERMINE WHICH BREAKERS TO BE SECURED IN THE EVENT OF A FIRE.
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000
Engineering
Issued 18 April 2000 Resolved
ENSURE ALL PORTABLE F/O TRANSFER HOSES ARE HYDROSTATICLY TESTED PRIOR TO USE AND MARK AS REQUIRED.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Lifesaving
Issued 18 April 2000 Resolved
PROVIDE MEANS OF DISEMBARKING INTO THE FWD LIFERAFT. LADDER SHALL BE APPROVED AND DESIGNED AS PER 46 CFR 199.110
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Construction/Loadline
Issued 18 April 2000 Resolved
MAKE PERMANENT REPAIRS TO WASTED KICK TUBE IN WAY OF THE STBD 01 DECK OUTSIDE OF "E" GENERATOR SPACE.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Engineering
Issued 18 April 2000 Resolved
SUBMIT DRAWINGS FOR USCG/ABS APPROVAL OF NEW AUX HEATING BOILER BOILERS PIPING, SAFETY, ALARMS AND OPERATING SHALL BE INSPECTED BY A USCG MARINE INSPECTOR PRIOR TO PLACING IN SERVICE.
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000
Lifesaving
Issued 15 April 1999 Resolved
ENSURE ALL PFDS, RING BUOYS, IMMERSION SUITS, LIFE BOAT,LIFE RAFT ARE MARKED TO REFLECT VESSEL'S NAME CHANGE.
Condition: Unknown
Due 30 June 1999
Resolved 30 June 1999
Construction/Loadline
Issued 15 April 1999 Resolved
MAKE PROPER NAME CHANGE IN WAY OF VESSEL'S BOW AND STERN.
Condition: Unknown
Due 30 June 1999
Resolved 30 June 1999
Navigation
Issued 16 April 1998 Resolved
PROVIDE VESSEL WITH A LINE-THROWING APPLIANCE AS APPROVED UNDER SERIES 160.040 OR 160.031. REF 46 CFR 108.597.
Condition: Unknown
Due 16 July 1998
Resolved 30 June 1998
Construction/Loadline
Issued 23 December 1997 Resolved
Vee and reweld fracture (from both sides) in way of the watertight bulkheadbetween the #2P and #3P ballast tanks.
Condition: Unknown
Due 24 February 1998
Resolved 24 February 1998
Construction/Loadline
Issued 18 March 1997 Resolved
Crop and renew deteriorated deck plating located in the chain locker compartment port side, fwd and aft of chain boxes.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Lifesaving
Issued 18 March 1997 Resolved
Renew wire ropes on both lifeboat falls.
Condition: Unknown
Due 18 September 1997
Resolved 2 September 1997
Navigation
Issued 18 March 1997 Resolved
Provide a hand lead line.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Electrical
Issued 18 March 1997 Resolved
Provide a weather tight cover for the rescue boat battery charger outlet.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Lifesaving
Issued 18 March 1997 Resolved
Conduct a weight test on the lifeboat.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Lifesaving
Issued 18 March 1997 Resolved
Conduct a life boat drill.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Documentation
Issued 18 March 1997 Resolved
Provide a current magnetic compass deviation card.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Engineering
Issued 6 April 1996 Resolved
CONDUCT A 1-1/2 x THE MAWP, HYDROSTATIC TEST ON VESSEL'S PORTABLE FUEL OIL TRANSFER HOSE. HOSE SHALL BE TESTED PRIOR TO USE.
Condition: Unknown
Due 30 April 1996
Resolved 13 June 1996
Lifesaving
Issued 6 April 1996 Resolved
REPLACE THE OUT DATED HYDROSTATIC RELEASING DEVICE ON THE NO.1 LIFERAFT.
Condition: Unknown
Due 30 April 1996
Resolved 13 June 1996
Engineering
Issued 7 April 1995 Resolved
PREPAIR THE AUX BOILER FOR A WATER/FIRE SIDE INSPECTION, OPEN MOUNTS FOR QUAD ANNUAL INSPECTION, CONDUCT A HYDROSTATIC TEST AT 1-1/4 TIMES THE MAWP,SET AND SEAL THE FWD AND AFT DRUM SAFETY VALVES.
Condition: Unknown
Due 7 April 1995
Resolved 7 April 1995
Construction/Loadline
Issued 20 December 1994 Resolved
MAKE PERMANENT REPAIRS TO BULWARK PORT SIDE AFT IAW CLASS (ABS) RECOMMENDATION DTD 20DEC94.
Condition: Unknown
Due 20 December 1994
Resolved 20 December 1994
Lifesaving
Issued 20 December 1994 Resolved
MAKE PERMANENT REPAIRS IWO ANGLE STANCHIONS SUPPORTING PORT L/B DECK IAW CLASS (ABS) RECOMMENDATION DTD 20DEC94. (COPY OF RECOMMENDATION ON FILE W/DETMS)
Condition: Unknown
Due 20 December 1994
Resolved 20 December 1994
Lifesaving
Issued 27 April 1994 Resolved
CONDUCT BOAT DRILL OF PORT AND STBD LIFEBOATS. EXERCISE CREW AT OARS/POWER TO THE SATISFACTION OF THE ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Engineering
Issued 11 April 1993 Resolved
CONDUCT ANNUAL HYDRO OF VESSELS OIL TRANSFER HOSE AT 1.5 TIMES THE M.A.W.P PRIOR TO THE NEXT TRANSFER, I.A.W. 33CFR156.170.
Condition: Unknown
Due 11 April 1993
Resolved 11 April 1993
Documentation
Issued 11 April 1993 Resolved
AMEND OIL TRANSFER PROCEDURE TO REFLECT CURRENT COAST GUARD REGULATIONS.
Condition: Unknown
Due 11 April 1993
Resolved 11 April 1993
Engineering
Issued 11 April 1993 Resolved
PROVE SATISFACTORY OPERATION OF THE OIL/WATER SEPARATOR ALARM AND SHUT DOWNIN WAY OF THE ENGINE ROOM.
Condition: Unknown
Due 11 April 1993
Resolved 11 April 1993
Engineering
Issued 2 October 1991 Resolved
Prior to next operating season, renew port boiler chemical feed line _x001C_ nipple as original. Nipple is to be a threaded connection.
Condition: Unknown
Due 2 October 1991
Resolved 2 October 1991
Construction/Loadline
Issued 3 April 1990 Resolved
REPAIR OR REPLACE LEAKING RIVITS IN FORWARD PEAK APPROXIMATLY 10 ON THE STARBOARD AND FOUR ON THE PORT IN WAY OF FIRST FRAME. THE ABOVE REPAIR TO COMPLETED IN NO CASE LATER THAN 16 APRIL 1990.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Electrical
Issued 6 March 1990 Resolved
LABEL SWITCHES IN MAIN LIGHT PANEL BOX, FWD PASSAGEWAY.
Condition: Unknown
Due 6 March 1990
Resolved 6 March 1990
Construction/Loadline
Issued 6 March 1990 Resolved
RENEW ALL PORT HOLE GASKETS ON BOTH PORT AND STBD SIDE OF MACHINERY SPACE.
Condition: Unknown
Due 6 March 1990
Resolved 6 March 1990
Electrical
Issued 6 March 1990 Resolved
REPLACE ALL BURNED OUT LIGHT BULBS IN WAY OF TUNNELS AND MACHINERY SPACE
Condition: Unknown
Due 6 March 1990
Resolved 6 March 1990
Fire Fighting
Issued 18 March 1989 Resolved
SERVICE 35# CO2 BOTTLE FOR PAINT LOCKER
Condition: Unknown
Due 18 March 1989
Resolved 18 March 1989
Lifesaving
Issued 18 March 1989 Resolved
CONDUCT BOAT DRILL, EXCERCISING HANDS IN LAUNCHING AND RETRIEVAL OF VESSELS LIFEBOAT.
Condition: Unknown
Due 18 March 1989
Resolved 18 March 1989
Electrical
Issued 18 March 1989 Resolved
REINSTALL & TEST OPERATION OF AFT STBD E/R VENT FAN MOTOR TO THE SATISFACTION OF THE ATTENDING USCG INSPECTOR & COGNIZANT OCMI, PRIOR TO DEPARTURE AT NEXT MILWAUKEE PORT CALL OR NOT LATER THAN 01APR89.
Condition: Unknown
Due 18 March 1989
Resolved 18 March 1989
Construction/Loadline
Issued 4 July 1988 Resolved
MAKE PERMANENT REPAIRS TO STB ANCHOR BOX TO SATISFACTION OF COGNIZANT OCMI.REPAIRS TO BE COMPLETED PRIOR TO 31 DEC 1988.
Condition: Unknown
Due 4 July 1988
Resolved 4 July 1988
Fire Fighting
Issued 20 March 1988 Resolved
CONVERT FIRE MAIN SYSTEM AND HOSES FROM 11 THREAD PER INCH TO NATIONAL STANDARD OF 9 THREADS PER INCH.
Condition: Unknown
Due 20 March 1988
Resolved 20 March 1988
Fire Fighting
Issued 20 March 1988 Resolved
SERVICE 100# CO2 FIXED REEL F/E LOCATED ON DUST COLLECTION PLATFORM.
Condition: Unknown
Due 20 March 1988
Resolved 20 March 1988
Fire Fighting
Issued 20 March 1988 Resolved
RENEW AND PROVE RELIEF VALVE ON THE STEAM RECIP. FIRE PUMP.
Condition: Unknown
Due 20 March 1988
Resolved 20 March 1988
Engineering
Issued 20 March 1988 Resolved
WRAP EXPOSED ASBESTOS LAGGING IN THE E/R AND BOILER ROOM.
Condition: Unknown
Due 20 March 1988
Resolved 20 March 1988
Engineering
Issued 11 March 1987 Resolved
CONDUCT FIRESIDE, WATERSIDE, MOUNTINGS REMOVED AND 1 1/4 HYDRO ON AUX BOILER BY 1 APRIL 1987. AUX BOILER IS NOT TO BE USED AFTER THIS DATE UNTIL ABOVE REQ IS COMPLETED IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 11 March 1987
Resolved 11 March 1987
Construction/Loadline
Issued 11 March 1987 Resolved
MAKE WATERTIGHT ALL OPENINGS ON THE MAIN DECK ABOVE THE FOREPEAK TANK. THE ABOVE REQUIREMENT TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI WITHIN 30 DAYS.
Condition: Unknown
Due 11 March 1987
Resolved 11 March 1987
Deck/Cargo
Issued 21 March 1986 Resolved
MAKE REPAIRS TO CRACKED MANIFOLD ON WINDLASS ROOM WINCH. RAPAIRS TO BE COMPLETED WITHIN 30 DAYS.
Condition: Unknown
Due 21 March 1986
Resolved 21 March 1986
Engineering
Issued 21 March 1985 Resolved
INSTALL AND TEST A 1" RELIEF VALVE ON EACH NEW WATER CONDITIONING TANK. INSTALLATION AND TESTING TO BE TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR AND ACCOMPLISHED PRIOR TO 04 APRIL 1985.
Condition: Unknown
Due 21 March 1985
Resolved 21 March 1985