None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 5 January 2026
…with no type recorded41
Operational controls None recorded without a removal date
Years with a record 32 calendar years (1992–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7035547
WDE6848
Flag
UNITED STATES
Maury page id
psix-94641

Documentation record

Registered dimensions (L × B × D)113.3 ft × 31.5 ft × 18.8 ft
Registered tonnagegross 197 / net 133
ITC dimensions (L × B × D)113.3 ft × 31.5 ft × 18.8 ft
ITC tonnagegross 436 / net 130
BuilderGULFPORT SHIPBUILDING CORPORATION · PORT ARTHUR, TX, UNITED STATES · built 1967
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMUSKEGON, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 16 December 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it197 - Dead Weight, Gross Ton
197 - Regulatory (Subpart C or D), Gross Ton
436 - Convention (Subpart B), Gross Ton
133 - Regulatory (Subpart C or D), Net Ton
130 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 11

Inspection history · 79

5 January 2026 Vessel Attendance · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8290276
5 July 2025 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8175201
1 May 2025 Administrative Inspection · Annual Inspection · Drydock Extension
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8127042
31 March 2025 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8102681
7 January 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8059536
29 October 2024 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8026416
21 October 2024 Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 8022074
7 October 2024 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8015919
17 May 2024 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7914021
13 March 2024 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7878217
28 July 2023 MTSA Verification · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7753893
24 July 2023 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7762613
20 October 2022 Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7583518
15 February 2022 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7396540
3 February 2022 Plan Review (Other than "T")
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7390212
31 January 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7388123
13 October 2021 DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7331639
1 July 2021 DAPI Audit
Administrative · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7241371
1 December 2020 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7105060
29 October 2020 Damage Survey
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7086442
13 October 2020 Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7077959
28 July 2020 Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7018219
1 May 2020 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6948415
14 April 2020 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6938908
22 October 2019 Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6840024
21 October 2019 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6838891
13 June 2018 Initial Certification · MTSA Verification · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6444141
9 February 2018 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6357819
5 February 2018 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6563347
30 January 2018 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6370585
30 August 2017 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6255188
1 February 2016 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5807697
21 October 2015 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5748130
22 July 2015 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5193690
28 May 2015 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5144246
3 April 2015 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5096242
2 January 2015 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5048130
26 February 2014 Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 4806152
4 December 2013 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4763547
18 January 2013 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4518673
28 October 2011 MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4180096
10 August 2011 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4113741
28 April 2011 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3997936
24 August 2010 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3832821
6 May 2010 Industry Initiated Exam · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3732219
21 January 2010 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 3667206
1 October 2009 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 3607018
5 March 2009 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3428632
5 February 2009 Load Line/Change of Employment
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3413413
18 March 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3166596
7 March 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3161569
31 January 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2867107
4 December 2006 MTSA Verification · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2833842
29 September 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2790099
29 September 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2790100
1 April 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2705761
9 March 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2599200
6 March 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2596820
2 March 2006 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2594792
7 November 2004 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2236286
7 November 2004 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2236987
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1973051
14 February 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 164493
26 February 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 76480
6 March 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 64260
12 November 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 767960
17 October 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 203695
23 October 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 763091
19 October 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 203540
25 March 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 101922
24 January 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1106932
27 November 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1183348
21 July 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 81716
21 July 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 223219
5 July 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 50553
2 February 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 105769
2 February 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 220196
10 April 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 67808
10 February 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 89099

Deficiency record · 25

10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 5 July 2025 Resolved
AIS must be maintained in effective operating condition, which includes the accurate input and upkeep of all AIS data fields. Vessel reported AIS on board the PRENTISS BROWN is not receiving information. Vessel is authorized to transit to Chicago to make repairs. Repairs shall be made prior to departure from Chicago.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2025
Resolved 5 July 2025
Resolution: Tech made repairs to AIS
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 May 2025 Resolved
Vessel has installed tonnage opening with watertight door in storage space aft of forepeak access. Tonnage opening is no longer maintaining a watertight boundary.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 5 May 2025
Resolution: Shims previously installed were removed and new hooks were manufactured. Installation is now flush against bulkhead.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 May 2025 Resolved
Alcohol test strips on board were expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2025
Resolved 13 May 2025
Resolution: Rcvd proof that the test strips are onboard.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 May 2025 Resolved
Emergency lighting was not present in berthing areas.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 7 May 2025
Resolution: Emergency flash lights were provided for each cabin.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 May 2025 Resolved
EPIRB battery was expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 7 May 2025
Resolution: New EPIRB installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 May 2024 Resolved
ON U.S. INSPECTED SHIPS, OILY WATER SEPARATING EQUIPMENT AND BILGE ALARMS MUST BE APPROVED. THE ROUTINE MAINTENANCE OF THE OILY WATER SEPARATING EQUIPMENT MUST BE CLEARLY DEFINED BY THE MANUFACTUR IN ASSOCIATED OPERATING MANUALS. THE OWS ON VESSEL HAS BY-PASS MODIFICATION SWITCH INSTALLED BY CREW. REMOVE UNAUTHORIZED MODIFICATION AND RESTORE OWS TO PROPER MANUFACTUR OPERATION OR TAG-OUT OWS SYSTEM, OR REMOVE OWS FROM VESSEL. OWS IS NOT TO BE OPERATED IN CURRENTLY MODIFIED STATE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 6 June 2024
Resolution: OWS modification has been removed from system and USCG witnessed proper startup operation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 May 2024 Resolved
ELECTRICAL EQUIPMENT MUST BE MARKED WITH ITS RESPECTED CURRENT AND VOLTAGE RATINGS. LABEL THE POWER PANEL IN BRIDGE STAIRWELL.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2024
Resolved 29 May 2024
Resolution: Panel has been labeled with voltage/amp ratings.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 May 2024 Resolved
INDIVIDUAL CIRCUIT BREAKERS ON DISTRIBUTION PANELS MUST BE LABELED WITH A DESCRIPTION OF LOADS THEY SERVE. PANEL 103 NEEDS BREAKER LOADS LABELED.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2024
Resolved 30 May 2024
Resolution: Individual loads on Panel 103 have been labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2024 Resolved
ELECTRICAL SYSTEMS AND EQUIPMENT MUST FUNCTION PROPERLY AND MINIMIZE SYSTEM FAILURES AND FIRE AND SHOCK HAZARDS. PORT SIDE ENGNIE ROOM PANEL BY BOILER NEEDS BLANK CIRCUIT BREAKER COVERS.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2024
Resolved 30 May 2024
Resolution: Openings inside of power panel have been covered with blank protectors.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 May 2024 Resolved
DETECTION SYSTEMS OR INDIVIDUAL DETECTORS MUST BE KEPT OPERATIONAL AT ALL TIMES WHEN CREW IS ONBOARD. PROPERLY MOUNT THE INDIVIDUAL SMOKE DETECTORS IN THE PORT AND STBD CREW BERTHING.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2024
Resolved 29 May 2024
Resolution: New individual detectors have been proberly mounted in port and starboard crew berthing.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2024 Resolved
ALL PORTABLE FIRE EXTINGUISHERS MUST BE APPROVED. PROVIDE AN APPROVED EXTINGUISHER BRACKET FOR DECK HEAD EXTINGUISHER.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 14 June 2024
Resolution: Portable extinguishers have been mounted in approved bracket types.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 May 2024 Resolved
THE FOLLOWING INFORMATION IS REQUIRED WHEN TESTING FIRE DETECTION SYSTEMS. DATES AND TESTS PERFORMED, THE NUMBER AND ANY OTHER INFORMATION ON IDENTIFICATION, THE RESULTS OF INSPECTION AND TESTS, NAME OF CREW MEMBER, SURVEYOR, OR AUDITOR MUST BE INCLUDED. PROVIDE EVIDENCE THIS INFORMATION IS RECORDED.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 29 October 2024
Resolution: Vessel is now recording fire detection maintenance/testing as per 142.240(c).
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 28 July 2023 Resolved
Found pilothouse alerter system to have been installed but was not yet hooked up or operational. Complete installation and demonstrate proper operation to attending CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2023
Resolved 26 August 2023
Resolution: Tech report received attesting to proper install & operational testing of the BNWAS system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 July 2023 Resolved
Sighted several PFEs not correctly mounted or installed with non-marine type brackets. Properly mount all PFEs with approved marine type mounting brackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2023
Resolved 26 August 2023
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 July 2023 Resolved
Witnessed LLO alarms function for the MDEs. No other other safety shutdowns were witnessed as this is usually accomplished by a third party vendor while ABS annual surveys are completed. Provide the Cognizant [name withheld] survey report & tech report once all main & aux machinery safety shutdown tests are completed.
Action required: 705 - Other - as specified
Due 8 November 2023
Resolved 17 May 2024
Resolution: Received CAT report for alarms on engines and gensets.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 October 2021 Resolved
Both Engine room bilge alarms are not working as designed. Provide tech report proving repair at next report or request extension.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 26 October 2021
Resolution: Tech report rcvd, tested all sat
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 October 2021 Resolved
Items in first aid kit are expired and kit is missing means to take blood pressure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 October 2021
Resolution: items have been replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 October 2021 Resolved
Various lights on 12v alarm panel on bridge/fly bridge are extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 October 2021
Resolution: Proof that all lights are operating rcvd.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 October 2021 Resolved
All training required by the Health and Safety plan is not being completed. Provide proof that training is established and followed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 December 2021
Resolution: Training has been implemented and commenced.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 13 October 2020 Resolved
hydraulic steering fluid Low level alarm for port steering system tank did not alarm in sufficient time. prove proper operation of port hydraulic steering fluid low level alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2020
Resolved 13 October 2021
Resolution: Alarm tested sat
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 October 2019 Resolved
Navigation light panel did not illuminate lamp indicating specific light trouble upon alarm. Crew effected repairs prior to completion of inspection.
Action required: 10 - Deficiency Rectified
Due 22 October 2020
Resolved 22 January 2020
Resolution: Lamp bulbs renewed.
Electrical › Electric Generation Source (service) › Panelboard
Issued 13 June 2018 Resolved
110 Volt breaker panel behind STBD gen was missing two breakers and no covers over the holes.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2018
Resolved 20 July 2018
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 13 June 2018 Resolved
Low L/O alarm would not sound until psi reached zero
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2018
Resolved 20 July 2018
Communications › Alarms/Indicators › High Water Alarm
Issued 13 June 2018 Resolved
High water alarm would not sound until temp reached over 225. Should be around 205 give or take a couple of degrees.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2018
Resolved 20 July 2018
Documentation › Markings/Placards › Warning Signs
Issued 13 June 2018 Resolved
General alarm placard for the engineroom was missing. Need to replace with new
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2018
Resolved 20 July 2018

Casualty record · 5

7 November 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2236286
1 April 2006Routine · role: Involved in a Marine Casualty · activity 2705761
31 January 2007Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2867107
7 March 2008Routine · role: Involved in a Marine Casualty · activity 3161569
10 August 2011Routine · role: Involved in a Marine Casualty · activity 4113741
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

MICHAELA MCALLISTER (2004–2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.