Inspection history · 49
4 September 2025
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8218247
5 March 2025
Examination of Repairs · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8088523
2 December 2024
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8041790
17 January 2024
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7850418
21 December 2023
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7842695
29 November 2023
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7830992
23 November 2022
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7598924
8 November 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7591266
31 October 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7586801
17 October 2022
DAPI Audit · MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7578626
22 August 2022
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7540874
8 November 2021
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7347689
19 October 2021
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7335832
15 October 2021
MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7333203
11 August 2021
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7288439
9 October 2020
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7074443
29 June 2020
Initial Certification · Administrative Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6992317
10 March 2017
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6410000
28 August 2015
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5228490
22 July 2015
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5193690
18 June 2014
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4907761
24 June 2013
DAPI Audit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4630415
28 January 2013
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4523774
17 January 2013
MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4518412
18 December 2012
Industry Initiated Exam · MTSA/ISPS Verification · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4503552
4 December 2012
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4496800
11 October 2012
Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4464765
18 July 2012
Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4383063
24 July 2009
Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3544770
25 August 2008
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3308846
11 March 2008
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3163031
22 September 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2784838
7 August 2006
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2738565
26 June 2006
MTSA Verification · Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2692382
4 August 2004
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2172319
8 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1961046
10 July 2002
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1645295
11 January 2002
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1477764
10 February 2001
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 453341
14 December 2000
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 669167
30 November 2000
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 70706
18 July 2000
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 10031
13 April 2000
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 84029
13 April 2000
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 669170
18 March 1996
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 756578
26 February 1996
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 197947
19 October 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 110106
12 May 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 181388
9 November 1993
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 32752
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 September 2025
Resolved
Machinery and electrical systems must be maintained for the safe operation of the vessel and personnel onboard. The shore power cable insulation is worn and chaffed. Replace the same.
46 CFR 143.205(c)
50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2025
Resolved 6 September 2025
Resolution: Received photgraphic evidence of completion.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 September 2025
Resolved
Two life buoys on a towing vessel of >26ft must be fitted w/ a floating water light approved under 161.010 or 161.110. the installed batteries for the water lights are not the ones approved by the manufacturer. Replace w/proper batteries
46 CFR 141.360(c)(3)
50c
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2025
Resolved 5 September 2025
Resolution: new batteries installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 4 September 2025
Resolved
A towing vessel must be maintained so that water tight integrity is not compromised. There is a ¼” hole on the PORT main deck. Make temporary repairs to the same prior to operation.
46 CFR 140.605(b)
701 c
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2025
Resolution: Received photographic evidence of completion.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 5 March 2025
Resolved
AFT section of keel plating plating appears to be buckling under the weight of the vessel on the dry dock blocking. Investigate cause and provide the local OCMI findings and develop repair plan for approval. Once approved, complete repair to affected area.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 December 2024
Resolved
A remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The valve must be operable from outside the space. The cable in way of the remote fuel shutoff parted. Make repairs and prove proper operation of the same.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2024
Resolution: Master provided satisfactory evidence of repairs and operation of the remote fuel shutoff valve.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 December 2024
Resolved
All portable fire extinguishers must be approved by the Commandant (CG-ENG). Multiple portable fire extinguisher brackets are not the correct bracket to maintain Commandant approval. Replace all portable fire extinguisher brackets as indicated by a Marine Inspector. Must be completed prior to completion of credit drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 August 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 November 2023
Resolved
Portside WTD's need to be labeled "Watertight Door Keep Closed on both sides Min 1" letters, 3 WTD's are missing markings.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2023
Resolved 17 January 2024
Resolution: All WTD's labeled keep closed.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 29 November 2023
Resolved
Forward Berthing passageway emergency lighting fixture is not operating, prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2023
Resolved 17 January 2024
Resolution: E light renewed.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 29 November 2023
Resolved
Bathroom GFCI is not functioning, prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2023
Resolved 17 January 2024
Resolution: GFCI in crew head renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 29 November 2023
Resolved
Emercency Escape WTD on starboard side is missing dogging bar.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2023
Resolved 17 January 2024
Resolution: Dogging bar provided.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 November 2023
Resolved
Two (2) forward berthing rooms are missing individual battery powered smoke detectors. Detectors must be UL 217
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2023
Resolved 17 January 2024
Resolution: Both battery powered smoke detectors renewed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 November 2023
Resolved
Forward winches have heat tape, permaninent extension cords and life vests for insulation. Submit to local OCMI plan o install permanent electrical system for Heat Tape including installing GFCI outlets at each winch.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2023
Resolved 17 January 2024
Resolution: Seperate GFCI outlets installed and extension cords removed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 29 November 2023
Resolved
Maintenance/Inspection/Drills must be provided to the OCMI showing completion for barge arresting gear.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 December 2023
Resolution: Record of drill provided
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 November 2023
Resolved
Provide records of alarm testing and required pressure vessel relief device testing to OCMI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2023
Resolved 21 December 2023
Resolution: Record of testing by Cat vendor provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for rating for watchkeeping
Issued 17 October 2022
Resolved
Crewmember filling OS requirement on COI did not have MMC on hand on board vessel. Keep MMC on hand while operating as a crewmember on board.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 October 2022
Resolution: Crewmember provided electronic copy. Crewmember will not sail on board until MMC is in hand on board vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 17 October 2022
Resolved
Immersion suites required on board have not been serviced as per 46 CFR 199.70(c).
46 CFR 141.350(b)
46 CFR 141.235
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 October 2022
Resolution: Certificates of annual servicing provided for immersion suits.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 October 2022
Resolved
Inflatable liferaft required on board has not been annually serviced as per 46 CFR 199.190.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 October 2022
Resolution: Raft was serviced and placed onboard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 October 2022
Resolved
Fire detection system on board has not been tested and maintained as per manufactures manual. Provide proof of testing.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 October 2022
Resolution: Tech report rcvd for servicing
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 October 2022
Resolved
Provide engine and genset manufactures manuals that provide recommended fuel filter replacement intervals.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2022
Resolved 10 November 2022
Resolution: Engine and genset manufacturer manuals are on board.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 17 October 2022
Resolved
Each watertight door and watertight hatch must be marked on both sides with "WATERTIGHT DOOR/HATCH, KEEP CLOSED". Label the exterior of all watertight doors as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2022
Resolved 23 November 2022
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 October 2022
Resolved
Each escape hatch and emergency exit used as a means o escape must be marked on both sides with 2" letters, "EMERGENCY EXIT, KEEP CLEAR".
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2022
Resolved 23 November 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 October 2022
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight function properly. The watertight door in way of the emergency escape from the forward storage locker area is not watertight. Make repairs to the watertight door making it watertight.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 October 2022
Resolution: Door was renewed and gasket was chaulk tested, welds were tested by pressure washer statement provided by [name withheld] vessel rep/Tankerman.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 October 2022
Resolved
The master must ensure all watertight doors function properly. Conduct maintenance on the following watertight doors and hatches:
1. Watertight door to forward storage locker (Loose hardware and doggs).
2. Watertight door to steering space (Loose hardware and doggs).
3. Watertight hatch to steering space (Doggs not securing).
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 28 October 2022
Resolved 28 October 2022
Resolution: Vessel master provided statement attesting to repairs and photos of caulk testing. Repairs done by Calumet River Shipyard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 October 2022
Resolved
Mark all ring life buoys with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2022
Resolved 10 November 2022
Resolution: All life rings have vessel name.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 October 2022
Resolved
Replace all expired first aid kit items.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2022
Resolved 10 November 2022
Resolution: First aid kit items that were expired have been replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 October 2022
Resolved
Replace the cover for the electric heater in the pilot house.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2022
Resolved 10 November 2022
Resolution: Electric heater cover has been replaced.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 October 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 19 October 2021
Resolution: FCC Station License was renewed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 October 2021
Resolved
Great Lakes Radio Agreement is expired. Renew Great Lakes Radio Agreement.
47 CFR 80
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 22 October 2021
Resolution: GLA was renewed for 2021-2022.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 October 2021
Resolved
Anchor light is not correctly spaced from red over red not under command lights (39"). Correctly space the lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2021
Resolved 22 October 2021
Resolution: Issued in error. Further investigation will be conducted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 October 2021
Resolved
Port and starboard wing voids need dewatering, hatch edges cleaned and tested for leaks.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2021
Resolved 20 October 2021
Resolution: Voids were pumped down and hatch edges cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 October 2021
Resolved
Install light covers/diffusers for all overhead lighting throughout vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 25 October 2021
Resolution: Covers/diffusers were installed for overhead lighting.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 October 2021
Resolved
Inflatable liferaft is not stowed for automatic release. Stow liferaft set up for automatic release.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 15 October 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 October 2021
Resolved
Towing winch control box has missing cover plate. Install missing cover plate.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 15 October 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 October 2021
Resolved
Emergency lighting in engine space is not operational. Repair or replace emergency lighting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 8 November 2021
Resolution: Emergency lighting was restored to proper operation in the engine space.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 October 2021
Resolved
Starboard forward emergency WTD has wasted gasket material. Replace WTD gasket material.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 8 November 2021
Resolution: Gasket material for starboard forward emergency WTD was replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 September 2020
Resolved
Replace all expired items in the First Aid kit and add all items required for Great Lakes Route.
46 CFR 140.435
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 October 2020
Resolution: Photos provided.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 29 June 2020
Resolved
Add vessel name to all immersion suits on board.
46 CFR 141.350(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 October 2020
Resolution: Statement of resolution provided new suits obtained.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 June 2020
Resolved
Install B-II fire extinguisher near the flammable storage locker on the STBD main deck as required by regulation.
46 CFR 142.255 (d)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 October 2020
Resolution: Extinguisher posted outside space, photo provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 29 June 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 October 2020
Resolution: Crewman was replaced with member who is up to date.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 29 June 2020
Resolved
Vessel has one void(centerline) full of ballast water. Vessel has no ballast water plan written.
33 CFR 151.2025 (a)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 October 2020
Resolution: Water was stripped out via vac truck, Potable water was brought onboard records maintained.
Communications › Audible Communications › Bell
Issued 11 March 2008
Resolved
Fog bell required IAW 33 USC 2033 and Nav Rule #3, 33 CFR 86.05
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2008
Resolved 25 August 2008
Resolution: Fog bell installed on vessel.
Lifesaving › Lifebuoys › Immediately Available
Issued 11 March 2008
Resolved
Port lifebouy not deployable (damaged bracket unable to lift off) IAW 46 CFR 25.25-5.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2008
Resolved 11 March 2008
Resolution: Bracket has been repaired can now remove lifebuoy, corrected on spot.
Fire Fighting › Remote Fuel Shutoff › General
Issued 11 March 2008
Resolved
Remote Fuel Oil shutoff needs to be labeled with operating instructions IAW 46 CFR 27.207
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2008
Resolved 25 August 2008
Resolution: Remote fuel valves properly labeled.
Operations/Management › FireFighting › Patrol System (Special Category Spaces)
Issued 11 March 2008
Resolved
Label sight fuel glasses with "close when underway" IAW Good Marine Practice.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2008
Resolved 25 August 2008
Resolution: Fuel sight glass valves labeled.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 11 March 2008
Resolved
Provide proof EPIRB registration transfer or replacement has been properly endorsed. Vessel currently has EPIRB from M/V Margaret M on board. Transfer request was sent no documentation available at this time.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2008
Resolved 25 August 2008
Resolution: Proper epirb registration onboard.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 26 June 2006
Resolved
Vessels port side vessel name signage needs to be replaced or repaired as required under 46 CFR 67.123.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 22 September 2006
Resolution: Name signage now attached
Documentation › Markings/Placards › Official Number (US)
Issued 26 June 2006
Resolved
Official number needs to permanantly affixed and worded properly as required under 46 CFR 67.121.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 22 September 2006
Resolution: Offical number now attached
Electrical › Lighting (service) › Lighting Fixture
Issued 26 June 2006
Resolved
Light fixture guards needed in machinery space, "Good Marine Practice".
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 22 September 2006
Resolution: Guards now in place
Communications › Alarms/Indicators › General Alarm
Issued 26 June 2006
Resolved
General alarm placard need near flashing red light in machinery space as required under 46 CFR 27.201 (a)(3).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 22 September 2006
Resolution: General alarm placard now in place
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 26 June 2006
Resolved
Fire detection panel zone's not labeled as required under 46 CFR 27.203.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 22 September 2006
Resolution: Fire detection panel properly marked
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 June 2006
Resolved
Guard needs to be properly installed around fuel oil transfer pump coupling, "Good Marine Practice".
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 22 September 2006
Resolution: Guard now in place
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 June 2006
Resolved
Clean up loose and exposed wiring in wheel house, "Good Marine Practice."
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 22 September 2006
Resolution: Installed new wheel house
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 June 2006
Resolved
Repair/ Replace exposed wiring on upper amber navigation light junction box, "Good Marine Practice."
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 22 September 2006
Resolution: Wiring repaired
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 26 June 2006
Resolved
Flame screens on all fuel tank vents need to be replaced due to wear, "Good Marine Practice."
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 22 September 2006
Resolution: Flame screens cleaned
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Service
Issued 26 June 2006
Resolved
Provide proof that portable B-V dry chemical meets U.S. Coast Guard specifications and approval as required under 46 CFR 27.303.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 22 September 2006
Resolution: New B-V dry chemical on board