Records from 2009 to 2026. Most recent: inspection, 22 June 2026.
Inspection history · 29
22 June 2026
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8407165
8 October 2025
Deficiency Check · Vessel Attendance · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8249681
29 July 2025
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8200428
14 May 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8138521
4 December 2024
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8044303
10 September 2024
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8001588
10 July 2024
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7975843
1 July 2024
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8139404
17 June 2024
Administrative Inspection · Initial Certification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7922821
24 May 2024
Equivalency · Administrative Inspection · Exemption
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7918688
14 July 2023
Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7742713
5 May 2023
Appeal
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7681815
30 December 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7614719
21 December 2022
Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7611889
22 September 2022
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7564207
21 December 2021
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7371247
9 July 2021
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7250880
19 May 2021
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7234668
4 May 2021
Annual Inspection · Damage Survey
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7189013
8 April 2021
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7196735
11 October 2020
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7080130
1 September 2020
Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7047528
21 January 2020
MARPOL Annex VI Survey · MARPOL Annex I Examination · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6893401
27 February 2019
MARPOL Annex I Examination · MTSA/ISPS Verification · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6633353
14 June 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6444287
13 July 2017
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6207948
6 April 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6118944
7 July 2016
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5932600
16 February 2016
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5816738
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 June 2026
Resolved
Each class 1 watertight door must have a quick action closing device operable from both sides of the door. The portside class 1 watertight door going into the 7P stairwell has damaged hardware rendering the door inoperable. Make repairs within 30 days and prior to any voyages beyond the boundary line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2026
Resolved 15 July 2026
Resolution: Received photographs of repair.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2026
No resolution recorded
All vessels shall have efficient guard rails or bulwarks on decks and bridges. The hand rails on the starboard and port stern corners are damaged and need repair. Additionally approximately 50 feet of hand rail on the fish loading deck is missing/damaged from the stbd bow aft. Repair and reinstall all handrail iaw 46 CFR 92.25-5.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2026 — due date passed with no resolution recorded
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 8 October 2025
Resolved
Each vessel must meet the requirements in subchapter S; Each vessel must have a stability letter...The stability letter sets forth the vessels conditions of operation. MI observed a substantial amount of water in the bilge in the vicinity of the space, 6c. Part 5 of HANNAH's stability letter states "The vessel’s bilges and voids shall be kept pumped to a minimum content at all times consistent with pollution prevention requirements." Pump bilge accumulation consistent with the requirements of the issued stability letter.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 26 May 2026
Resolved 26 May 2026
Resolution: O/o provided picture of dry and clean bilge as evidence of maintaining the requirements listed on stability letter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 October 2025
No resolution recorded
All auxiliary machinery must be designed, constructed, and installed in accordance with the provisions of this subchapter. MI observed the #6 and #9 generator sets were undergoing trouble shooting at the time of inspection. Perform functional tests with attending marine inspector during follow on inspection with SEC Western Alaska.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 October 2025
No resolution recorded
Construction of vessel shall be such as to minimize fire hazards. Two penetrations in the engine rm port side and one on the main deck centerline adjacent to the hotel need to be properly sealed. Verified during follow on inspection with SEC Western Alaska.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2026 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 8 October 2025
Resolved
Lifesaving appliances and arrangements are subject to tests and inspections described in paragraph (b) of this section during vessel boardings to ensure that the appliances and arrangements comply with applicable requirements, are in satisfactory condition, and remain fit for the service. Vessel unable to launch life saving appliances, nor conduct drills due to crew complement being onboarded upon arrival in Alaska. Tests/Drills to be completed upon arrival.
Action required: 703 - Prior to bunkering operations
Due 30 June 2026
Resolved 22 June 2026
Resolution: Drills witnessed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 July 2025
No resolution recorded
There shall be at least two means of escape from areas where the crew may be quartered or normally employed. Design of deck coaming and scuppers permits emergency escape hatches from below deck spaces in the vicinity of the fish loading area (aft of midship; port and starboard) tow be submerged. Escape routes must be unobstructed. 46 CFR 92.10-5
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 July 2025
Resolved
A space used in the sorting or processing of fish in which water is used must be fitted with dewatering system capable of dewatering the space under normal conditions of list and trim at the same rate as water is introduced. The dewatering system must be interlocked with the pump(s) supplying water to the space, so that in the event of failure of the dewatering system, the water supply is inactivated. Main Deck Fish House above 6C and 7C dewatering pump was inoperable due to a ground fault. This failure resulted in the water introduced into the space to spill outside of the conveyor belt system, leading to water cascading down from upper decks within the fish house to the main deck where 6 inches of pooled water on main deck within the fish house. System not fitted with interlock to prevent water accumulation. 46 CFR 28.255 & 46 CFR 91.27–1(a)(4)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2025
Resolved 22 June 2026
Resolution: Main Deck Fish House is equipped with adequate scuppers to prevent water accumulation. See narrative for explanation.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 29 July 2025
Resolved
Each inflatable buoyant apparatus must meet the liferaft stowage requirements in § 199.130(c), being arranged for float-free launching. The arrangement must ensure that
the inflatable buoyant apparatuses, when released and inflated, are not dragged under by the sinking vessel. A hydrostatic release unit used in a float-free arrangement must be approved under approval. Vessel's IBAs are lashed down and not float free. Hydrostatic release does not cut cradle strap. 46 CFR 199.640(j)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 29 July 2025
Resolved 8 October 2025
Resolution: IBA was strapped for transit, straps not removed. Educated vessel crew to remove straps upon arrival to fishing grounds.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 29 July 2025
Resolved
Every crewmember must participate in at least one abandon-ship drill and one fire drill every month. Additionally, drills must be held before sailing when a vessel enters service for the first time, after modification of a major character, or when a new crew is engaged. Drills were conducted when crew arrived in early June, but monthly drills were not conducted until attending marine inspector came in late July. 46 CFR 199.180(c)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 29 July 2025
Resolution: Provided information to PIC in CFR about frequency of required drills.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 29 July 2025
Resolved
Every crewmember must be given instructions that include the operation and use of fire-extinguishing appliances. Cook on-board was unfamiliar with the location of designated fire-fighting appliances in the galley and the operation of the manual galley hood-extinguishing system installed. 46 CFR 199.180(g)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 July 2025
Resolution: Provided information to cook on location of fire appliances in his workplace. Communicated importance of on-board training requirements and safety orientation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2025
Resolved
Each lifejacket must be marked - In block capital letters with the name of the vessel. Lifejackets not currently marked.
46CFR199.70(b)(3)(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 29 July 2025
Resolution: Verified lifejacket markings during drills
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 May 2025
Resolved
Machinery compartments containing equipment for ammonia must be fitted with a sprinkler system providing an effective water spray and having a remote-control device located outside the compartment. Vessel has approved plans, but has nto finished installation of required equipment.
46CFR58.20-15(b)
Action required: 705 - Other - as specified
Due 30 September 2025
Resolved 11 May 2026
Resolution: Verified operation of installed sprinkler system IAW MSC approved plans.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 14 May 2025
Resolved
Lifesaving appliances and arrangements are subject to tests and inspections described in paragraph (b) of this section during vessel boardings to ensure that the appliances and arrangements comply with applicable requirements, are in satisfactory condition, and remain fit for the service. Vessel unable to launch life saving appliances, nor conduct drills due to crew complement being onboarded upon arrival in Alaska. Tests/Drills to be completed upon arrival.
46CFR199.45(c)(2)
705-Prior to operations
Action required: 705 - Other - as specified
Resolved 29 July 2025
Resolution: Conducted fire, abandon ship, and man-overboard drills.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 September 2024
Resolved
After any survey of the vessel made under 46 CFR 42, no change shall be made in the vessel's structure,
equipment, arrangement, or scantlings without prior
specific approval of the issuing authority. Vessel removed unauthorized portions of the bulkhead on the weather deck, affecting their watertight integrity after issuance of a temporary Load Line Certificate.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 21 May 2025
Resolution: Resolved upon issuance of permanent loadline.
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 10 September 2024
Resolved
The weather deck must have freeing ports, open rails, and scuppers, as necessary, to allow rapid clearing of water under all weather conditions. The vessel accumulates standing water in compartments on the weather deck and has no approved means of drainage.
Condition: Design Flaw
Action required: 30 - Ship detained
Resolved 21 May 2025
Resolution: Resolved upon issuance of permanent loadline
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 10 September 2024
Resolved
No person may operate an oceangoing ship of 400 gross tons and above but less than 10,000 gross tons unless it is fitted with approved 15 parts per million (ppm) oily-water separating equipment for the processing of oily mixtures from bilges, or fuel oil tank ballast and an oil residue (sludge) tank or tanks of adequate capacity to receive oil residue that cannot be dealt with otherwise. The vessel has no permanent means of retaining bilge water, there was excessive oily water in the bilge, the temporary tank on board was not utilized and is of insufficient capacity for vessel operations.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 14 May 2025
Resolution: Verified installation and operation of installed system IAW approved plans.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2024
Resolved
Electrical installations on vessels must ensure maintenance of services necessary for safety under normal conditions and the protection of crew, other persons, and the vessel from electrical hazards. The vessel has exposed electrical wiring from a previous fire in a compartment that regularly produces condensation and has standing water.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2024
Resolved 28 April 2025
Resolution: Verified new wire runs installed, conduits removes and new wires installed on wire tray.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 September 2024
Resolved
Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position. Oxygen and acetylene tanks were secured to a pillar with line, not in a rack, and in standing water.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2024
Resolved 14 May 2025
Resolution: Verified permanantly installed cylinder racks on deck, welded, above areas of standing water.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2024
Resolved
Non-conducting deck coverings, such as non-conducting mats or gratings, suitable for the specific switchboard voltage must be installed for personnel protection at the front and rear of the switchboard and must be sufficient width to suit the operating space. The switchboard in the emergency generator space did not have non-conducting deck coverings.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2024
Resolved 18 December 2024
Resolution: Non conductive matting observed in emergency generator skid.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2024
Resolved
Electric equipment must be arranged, as far as practicable, to prevent mechanical damage to the equipment from the accumulation of dust, oil vapors, steam, or dripping liquids. Condensation and/or a water leak from piping was observed actively dripping onto an energized charging appliance in the generator space.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2024
Resolved 11 December 2024
Resolution: Drip shields were installed over battery chargers.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 10 September 2024
Resolved
Piping systems shall be installed so that under no condition will the operation of safety or relief valves be impaired. The vessel removed all of the motor operated valves from the ballast system due to them being inoperable.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2024
Resolved 28 April 2025
Resolution: Ballast plan approval recevied with new valves.
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 10 September 2024
Resolved
Vessels of 500 gross tons or more on an international voyage, must be provided with at least one international shore connection complying with ASTM F 1121. The international shore connection on deck was missing appropriate hardware components.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2024
Resolved 21 May 2025
Resolution: Shoreside connection installed IAW approved plans and oily water holding system.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 10 September 2024
Resolved
Alterations or repairs of machinery or piping systems shall be done under the cognizance of the Officer in Charge, Marine Inspection and in accordance with applicable regulations. The water recirculation piping system is actively leaking and has been temporarily repaired with electrical tape.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2024
Resolved 28 April 2025
Resolution: Previously cleared by SMI
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 19 August 2024
Resolved
The ring, lines and letter shall be painted in white or yellow on a dark ground or in black on a light ground. They shall also be permanently marked on the sides of the vessels to the satisfaction of the assigning authority. Load line is not permanently marked on vsl.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2024
Resolved 21 May 2025
Resolution: Resolved upon issuance of permanent loadline.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 17 June 2024
Resolved
Each vessel subject to load line requirements shall carry on board a valid certificate attesting to compliance with such requirements. Vessel did not have approved final load line certificate and corresponding stability documentation on board. 46 CFR 42.09-1(b)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 17 June 2024
Resolved 19 August 2024
Resolution: Vessel has received short term load line and final stability documentation for both load line and manned fish tender operations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2024
Resolved
All applicable electrical plans under 46 CFR 110.25-1 must be submitted for Coast Guard review, addressing all outstanding comments when returned. Vessel has resubmitted revised plans as per MSC correspondence E2-2401833, but has not received approved plans. Once plans are approved, address outstanding comments to the satisfaction of OCMI (if applicable). 46 CFR 110.25-1
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 17 June 2024
Resolved 24 June 2025
Resolution: Recevied electrical approval from MSC. MI previously walked electrical installation IAW submitted plans.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 June 2024
Resolved
Flexible non metallic hoses and fittings shall conform to SAE J1942 and J1475 specifications. Vessel generators (C18) are using non-compliant hoses for their generator cooling return systems. (02) generators are using 3" hoses that are marked w/J-1942, but not fully tested/approved to the standard. (06) generators are using non-J1942 hoses designed for turbocharger aftercooling. 46 CFR 56.60-25(b)
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 17 June 2024
Resolved 28 April 2025
Resolution: Verified correct hoses installed on 06 gensets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2024
Resolved
Each cable installation must meet IEEE 45.8-2016 if not constructed to IEC 60092-353. Such installations should provide support by means of metallic banding to prevent undue sag, but in no case should exceed the distance between frames or 610 mm (24 in.), whichever is less. Locations throughout the vessel are not provided with metallic banding spaced 24 inches apart, which in some areas permitted sagging of cable installations. 46 CFR 111.60-5(a)
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Due 17 June 2024
Resolved 11 December 2024
Resolution: Steel bands are installed throughout vessel
08 - Alarms › N/A - No Subsystem › General alarm
Issued 17 June 2024
Resolved
All general alarm bells shall be identified by red lettering at least 1/2 inch high: “GENERAL ALARM—WHEN BELL RINGS GO TO YOUR STATION.” General alarm speakers are not identified with required signage. 46 CFR 97.37-7
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2024
Resolved 28 April 2025
Resolution: Verifeid posted signage in areas having general alarm bells.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 June 2024
Resolved
There shall be at least two means of escape from areas where the crew may be quartered or normally employed. 5P, 7P, and 7S vertical emergency escape ladders were unable to be opened because they were either blocked on deck (5P or 7P) or was stuck closed (7S). 46 CFR 92.10-5
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 17 June 2024
Resolved 17 June 2024
Resolution: Removed items blocking exit and opened all vertical exits.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 21 December 2021
Resolved
Coamings and hatchway covers to exposed hatchways on decks above the superstructure deck shall comply with the requirements of the assigning authority. 11 Hatch covers were found to be missing a stud or multiple studs, preventing it from being completely secured to the deck and watertight. Grind and repair as original.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 21 January 2022
Resolved 31 December 2021
Resolution: Repaired studs on manhole covers.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 4 May 2021
Resolved
Inset observed on Port side, just aft amidships, FR 36-37, approx 10'x8'x8".
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 July 2021
Resolved 9 July 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 4 May 2021
Resolved
Void space covers on deck missing studs and broken gaskets, impairing water tight envelope.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 15 July 2021
Resolved 9 July 2021
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 27 February 2019
Resolved
Vessel IOPP expired.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2019
Resolved 23 March 2019
Resolution: Issued IOPP.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 27 February 2019
Resolved
Original COD was not onboard the vessel.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2019
Resolved 22 April 2019
Resolution: Verified new COD.