Records from 2003 to 2026. Most recent: inspection, 18 February 2026.
Documentation record
Registered dimensions (L × B × D)87.4 ft × 32.0 ft × 13.9 ft
Registered tonnagegross 148 / net 31
ITC dimensions (L × B × D)87.4 ft × 32.0 ft × 13.9 ft
ITC tonnagegross 235 / net 70
BuilderWASHBURN & DOUGHTY ASSOCIATES INC · EAST BOOTHBAY, ME, UNITED STATES · built 2003
Hull materialSteel
PropulsionDiesel Outdrive
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 September 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it31 - Regulatory (Subpart C or D), Net Ton
70 - Convention (Subpart B), Net Ton
148 - Regulatory (Subpart C or D), Gross Ton
235 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 37
18 February 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8311286
28 January 2025
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8071116
6 December 2024
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8044458
15 February 2024
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7866398
16 January 2024
Administrative Inspection · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7849630
19 July 2023
Underwater Inspection in lieu of Drydock · Administrative Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7744709
14 June 2023
Drydock Extension
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7712945
21 March 2023
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7634458
15 March 2022
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7408780
9 June 2021
Internal Structural Exam · Underwater Inspection in lieu of Drydock · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7226186
6 May 2021
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7205669
24 March 2021
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7162463
13 March 2020
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7012394
18 June 2019
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6723630
12 April 2019
Excursion Permit
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6661303
17 October 2018
Deficiency Check · Initial Certification · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6561624
6 September 2017
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6262327
25 January 2017
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6077736
26 November 2016
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6048660
7 March 2015
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5080631
15 March 2013
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4552849
7 December 2012
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4498174
7 December 2012
Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4498241
3 February 2011
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3940407
6 March 2009
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3432103
8 January 2009
Administration
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3390825
3 June 2008
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3227900
11 February 2008
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3149789
23 May 2006
Uninspected Other · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2667222
13 January 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2567093
7 December 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2559819
5 April 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2328338
7 November 2004
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2236286
28 June 2004
Uninspected Other
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2113398
26 February 2004
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2024996
30 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2003951
13 June 2003
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1816354
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 February 2026
Resolved
Each towing vessel must perform the tests of all "other essential systems" (emergency dewatering systems), at least once every 3 months. The tests required by this section must be recorded in accordance with 46 CFR 140. Vessel crew was not ready to test the emergency dewatering system and there were no records presented to show evidence of required 3 months testing.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2026
Resolved 17 April 2026
Resolution: Witnessed satisfactory test of bilge pumping system.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 18 February 2026
No resolution recorded
No Certificate of Documentation issued under this part will be deemed valid for operation of the vessel until the vessel is marked in accordance with 46 CFR Subchapter G. The hailing port must be marked on some clearly visible exterior part of the stern of the vessel. The hailing port marked on the stern of the vessel (Boston) does not match the hailing port on the vessel's Certificate of Documentation (New York). Deficiency to be rectified prio to next credit hull exam due to restraints on hotwork needed to effect repairs.
Condition: Improper Installation
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 February 2026
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Liferaft hydrostatic unit was expired.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2026
Resolved 17 April 2026
Resolution: Hyrostatic release unit replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 February 2026
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Aft main deck life buoy grab line was dryrotted and wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2026
Resolved 17 April 2026
Resolution: Life buoy grab line replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 February 2026
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Port side main deck life buoy water light batteries were expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2026
Resolved 17 April 2026
Resolution: Life buoy water light batteries replaced. Tested light, satisfactory.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 February 2026
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires that is installed, tested, and maintained in accordance with the manufacturer's design manual. Testing equipment, in accordance the manufacturer's design manual, was not available on board to test the fire-detection system.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2026
Resolved 17 April 2026
Resolution: Tested heat detector in engine room with heat gun in accordance with manufacturer's design manual.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 February 2026
Resolved
Emergency lighting must be provided for all internal crew working and living areas. The emergency light in the engine room IVO exit stair failed to operate under an emergency condition test.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2026
Resolved 17 April 2026
Resolution: Emergency light fixed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 February 2026
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. First aid kit had expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2026
Resolved 17 April 2026
Resolution: Inspected first aid kit and found all items not past their expiration date.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 January 2024
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Remote shutoff for port aft day tank found with broken connection from the pull cable to valve handle after testing. 46 CFR 143.260(b) - 17 c
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2024
Resolved 22 January 2024
Resolution: Corrected on the spot: crew was able to replace connection from pull handle to valve, tested all sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 March 2021
Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications. Electronic and paper charts are not updated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2021
Resolved 20 April 2021
Resolution: Charts updated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 March 2021
Resolved
A towing vessel 79 feet or more in length must carry four life buoys. One of the four life buoys is not in serviceable condition.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2021
Resolved 20 April 2021
Resolution: life buoys replaced.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 March 2021
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217. Vessel does not have smoke detection in berthing spaces.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2021
Resolved 20 April 2021
Resolution: Smoke detection installed in berthing areas.