Records from 2008 to 2025. Most recent: operational control imposed, 6 November 2025.
Inspection history · 24
6 November 2025
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8265366
4 November 2025
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8262696
6 December 2024
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8044458
5 June 2024
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7927305
7 May 2022
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7441103
26 January 2021
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7130784
9 March 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6923302
19 August 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6790635
25 March 2019
Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6648403
23 June 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6453102
13 April 2018
COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6390924
16 February 2018
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6356333
5 April 2017
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6118061
19 April 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5857555
10 September 2015
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5717885
6 September 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5236491
23 March 2014
Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4821262
23 December 2011
COC-CHEM Annual · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4213139
29 December 2010
ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3917362
2 September 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3840641
27 March 2009
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3441352
20 March 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3437382
29 December 2008
MARPOL Annex V Examination · ISPS I Exam · PII Safety Exam · Ballast Water Examination · COC-TVE Renew · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3385762
22 December 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3383845
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 January 2021
Resolved
17ac The condition of the ship and its equipment shall be monitored to comform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The jacket water cooling line is leaking and appears to have been leaking for an extended period of time.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 January 2021
Resolved 3 February 2021
Resolution: Vessel submitted class report clearing deficiencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 January 2021
Resolved
The condition of the ship and its equipment shall be monitored to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Insulation is worn and wasted around several fuel lines.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 January 2021
Resolved 3 February 2021
Resolution: Vessel submitted class report clearing deficiencies.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 23 December 2011
Resolved
Deck seal is leaking water at supply line to deck seal and at low water indicating sensor. Provide class report attesting to the leaks and repair. SOLAS II-2 REG 4.5.5
40a
Action required: 705 - Other - as specified
Due 6 January 2012
Resolved 23 December 2011
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 23 December 2011
Resolved
Deck coaming has vertical cracks at welds that may propagate to the deck. Class to attend vessel to provide repair proposal to arrest further cracking of coaming that could compromise the deck. Portside aft of frame 140. Starboard aft of frame 140; fwd of frame 110 and fwd of frame 105. SOLAS II-2 Reg 4.5.5
17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2011
Resolution: Recieved class report.
Navigation › Piloting/Steering › Gyro Compass
Issued 30 August 2010
Resolved
Malfunctioning secondary gyrocompass.
Action required: 705 - Other - as specified
Resolved 2 September 2010
Resolution: The supporting liquid in the gyrocompass was strained and reinstalled into the unit. After turning the sphere back on again, the unit was functioning normally and rendered fully ready for service, as per tech report.