Inspection record

Last inspected 15 July 2025
…with no type recorded23
Operational controls None recorded without a removal date
Years with a record 29 calendar years (1991–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7217133
WDG2188
113936
Flag
UNITED STATES
Maury page id
psix-113936

Documentation record

Registered dimensions (L × B × D)89.5 ft × 28.0 ft × 14.4 ft
Registered tonnagegross 181 / net 123
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSOUTHERN SHPBLDG CORP · SLIDELL, LA, UNITED STATES · built 1972
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 10 September 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it181 - Regulatory (Subpart C or D), Gross Ton
123 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 50 inspections, each with its date, unit and type; 25 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 15 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 15

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

FREEDOM Towing Vessel · MISLE 609006 · 6 December 2024 · activity 8044458LIBERTY Towing Vessel · MISLE 623727 · 6 December 2024 · activity 8044458TORM LENE Tank Ship · MISLE 993195 · 6 December 2024 · activity 8044458JUSTICE Towing Vessel · MISLE 1044322 · 28 December 2014 · activity 5045069R.T.C. NO. 380 Tank Barge · MISLE 47041 · 11 October 2012 · activity 4465012KRAKEN Freight Barge · MISLE 509116 · 26 October 2010 · activity 3888833H. J. REINAUER Towing Vessel · MISLE 175148 · 7 December 2005 · activity 2559819MAVERICK Towing Vessel · MISLE 566161 · 7 December 2005 · activity 2559819LIBERTY Towing Vessel · MISLE 623727 · 7 December 2005 · activity 2559819B. F. T. NO. 50 Tank Barge · MISLE 47081 · 13 March 1997 · activity 56864B. F. T. NO. 50 Tank Barge · MISLE 47081 · 5 January 1996 · activity 37068HERCULES Towing Vessel · MISLE 69143 · 15 February 1995 · activity 181614JOHN REINAUER Towing Vessel · MISLE 102643 · 15 February 1995 · activity 181614H. J. REINAUER Towing Vessel · MISLE 175148 · 15 February 1995 · activity 181614PROTECTOR Towing Vessel · MISLE 122955 · 19 August 1994 · activity 73277B. F. T. NO. 50 Tank Barge · MISLE 47081 · 21 January 1994 · activity 182367CB 351 Freight Barge · MISLE 72677 · 21 January 1994 · activity 182367OSG 214 Tank Barge · MISLE 48375 · 24 February 1993 · activity 186106OSG HONOUR Towing Vessel · MISLE 135565 · 24 February 1993 · activity 186106

Inspection history · 50

15 July 2025 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8173040
6 December 2024 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8044458
25 June 2024 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7933568
20 March 2024 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7878230
22 December 2023 Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7841690
12 October 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7795775
28 July 2023 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7757834
26 September 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7566386
11 January 2022 Underwater Inspection in lieu of Drydock · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7378546
18 November 2021 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7353684
19 October 2021 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7335648
5 October 2021 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7326535
2 November 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7088266
25 April 2019 MTSA Verification · Deficiency Check · Initial Certification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6670262
27 December 2018 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6603438
26 October 2017 MTSA Verification · Industry Initiated Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6295955
27 September 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6281032
24 May 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6168657
28 December 2014 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5045069
24 April 2013 Risk-based Targeted Exam · MTSA Verification · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4569775
11 October 2012 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4465012
1 February 2012 Administration
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4235829
26 October 2010 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3888833
12 February 2010 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3679147
28 October 2009 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3626884
18 April 2009 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3466985
8 January 2009 Administration
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3390829
23 October 2008 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3350222
2 March 2007 MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3123590
6 December 2006 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2835223
23 May 2006 MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2667263
7 December 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2559819
10 March 2004 Uninspected Towing Vessel
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2022227
30 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2003954
31 October 2000 Uninspected Towing Vessel
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1054699
5 March 1999 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 426306
20 August 1998 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 795790
23 June 1998 Uninspected Towing Vessel
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1130274
15 June 1998 Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 793946
22 January 1998 Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1108379
8 January 1998 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 10674
13 March 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 56864
5 January 1996 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 37068
15 February 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 181614
8 February 1995 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 375088
19 August 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 73277
21 January 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 182367
24 February 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 186106
13 January 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 719901
21 December 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 170127

Deficiency record · 25

05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 15 July 2025 Resolved
Towing vessels must meet the communications requirements of 33 CFR part 26 and 33 CFR 164.72, as applicable. MI observed that the DSC radio was not connected to GPS, meaning no position is transmitted when using the DSC function.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2025
Resolution: MI witnessed GPS connected to DSC radio
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 July 2025 Resolved
The hose must be a lined commercial fire hose 15 meters (50 feet) in length, at least 40 millimeters (1.5 inches) in diameter. MI observed the hose in the engineroom had a bulge. Operator destroyed the hose and replaced with a new one.
Action required: 10 - Deficiency Rectified
Resolved 15 July 2025
Resolution: Operator replaced the damaged hose with a new one.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2025 Resolved
Each lifejacket must be marked: In block capital letters with the name of the vessel. MI observed 04 PFDs were not marked with the vessel's name. Operator labeled the PFD's prior to end of the inspection.
Action required: 10 - Deficiency Rectified
Resolved 15 July 2025
Resolution: Operator labeled the PFDs prior to end of the inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 October 2023 Resolved
Rules in this subpart (Rules 20–31) (§§ 83.20 through 83.31) shall be complied with in all weathers. MI observed that navigation lights indicating towing arrangements were inop. Until corrected, vessel is restricted to daytime towing operations.
Action required: 705 - Other - as specified
Resolved 4 November 2024
Resolution: Operator repaired nav lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2023 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. MI observed no guards on the exposed shafts of both the lube oil supply pump and the capstain hydraulic pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2023
Resolved 14 November 2023
Resolution: MI observed machinery guards installed on the two pumps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 October 2023 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. MI observed that the AMP and KWH meters on the port generator were inop.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2023
Resolved 14 November 2023
Resolution: MI observed the generator panel was equipped with a multifunction display that displayed AMPs and KWHs.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 September 2022 Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. No smoke detectors present in any of the berthing spaces.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2022
Resolved 4 November 2022
Resolution: Compliant alarms installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 5 October 2021 Resolved
The load line marks placed on a vessel shall be attested to by a valid load line certificate. The issuing authority shall not deliver any required load line certificate to the vessel until after its surveyor has ascertained that the correct placement of the marks on the vessel's sides has been confirmed. The load line certificate shows a mark for WMA (Winter North Atlantic) but it was not marked on the sides of the vessel. Correct prior to dry dock credit.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 18 November 2021
Resolution: Vessel submitted photos showing corrected loadline affixed to vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2020 Resolved
Vessel owners must pay inspections fees required by 46CFR Part 2 before inspection services are provided. Vessel inspections are currently in collection status.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 11 November 2020
Resolution: Verified user fees were paid in MISLE.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 November 2020 Resolved
Each towing vessel on a coastwise route must carry a Category 1, 406 MHz satellite EPIRB. Vessels EPIRB is not onboard, vessel is restricted to Lakes, Bays and Sounds Route no more than 3 NM from shore until EPIRB is back on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 11 November 2020
Resolution: Received email with pictures of installed EPIRB.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 November 2020 Resolved
The fire detection system control panel must draw power from two sources. The panel currently has a no battery power fault on all 3 zones.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 18 November 2020
Resolution: Received picture of installation of new batteries for fire detection panel with no alarm faults.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 November 2020 Resolved
All lifesaving equipment must be properly maintained and ready for use at all times. The upper deck life buoys on port and starboard side grab lines are deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 4 November 2020
Resolution: Operator sent pictures of newly installed grab lines on the life buoys.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 November 2020 Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit. The eye wash liquid and medication in the first aid cabinet are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 4 November 2020
Resolution: Operator sent pictures of new medication and eye wash liquid.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 November 2020 Resolved
Pressure vessels must have the MAWP indicated and be visible to the crew. The nameplate for the 04 pressure vessels in the engine room were painted over and could not see MAWP.
Action required: 10 - Deficiency Rectified
Due 2 November 2020
Resolved 2 November 2020
Resolution: Crew grinded off paint from nameplates while onboard.
Documentation › Certificates/Documents
Issued 10 March 2004 Resolved
Obtain annual survey and endorsement for ABS Load Line Certificate. LEGACY COMPONENT DESC: International Load Line Certificate
Action required: 705 - Other - as specified
Due 3 April 2004
Resolved 10 March 2004
Resolution: BT&T has scheduled annual survey w/ABS Surveyor. Until satisfactory completion, the tug will not be operated seaward of the Boundary Line. Cleared def.
Lifesaving
Issued 5 March 1999 Resolved
3 life rings are missing reflective tape.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Lifesaving
Issued 5 March 1999 Resolved
The name of the tug was not properly marked on 4 life rings.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Accommodation/Occupational Safety
Issued 15 June 1998 Resolved
Ensure marine sanitation device has placard posted and a copy of the operating proceedures is onboard as required.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Lifesaving
Issued 15 June 1998 Resolved
Replace lagging on port and starboard generators as required.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Fire Fighting
Issued 15 June 1998 Resolved
Ensoure all fire extinguishers have been serviced annually as required.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Navigation
Issued 15 June 1998 Resolved
Install lights enabling the vessel to display Restricted In Ability To Manuever as required.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Navigation
Issued 15 June 1998 Resolved
Provide evidence that chart corrections are being made.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Lifesaving
Issued 15 June 1998 Resolved
Remove debris on top of float free liferaft.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Navigation
Issued 15 June 1998 Resolved
Ensure all navigation lights meet UL 1104 standards.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Lifesaving
Issued 15 June 1998 Resolved
Remove old liferaft instructions and replace with instructions for liferaftthat is currently onboard.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998