Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)93.0 ft × 36.0 ft × 17.6 ft
Registered tonnagegross 197 / net 134
ITC dimensions (L × B × D)93.0 ft × 36.0 ft × 17.6 ft
ITC tonnagegross 399 / net 119
BuilderJ M MARTINAC SHIPBUILDING CORPORATION · TACOMA, WA, UNITED STATES · built 2009
Hull materialSteel
PropulsionUnknown
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 10 September 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it399 - Convention (Subpart B), Gross Ton 197 - Regulatory (Subpart C or D), Gross Ton 119 - Convention (Subpart B), Net Ton 134 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 28 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each, 2 without one; operational controls, none recorded without a removal date; 21 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2024No resolution recorded
New installations that are not replacements in kind must comply with the requirements of subpart C of this part. Verification of compliance with the machinery and electrical design standards in this subpart is obtained by following the provisions in 46 CFR 144.135 through 144.145. Provide a verification of compliance with design standards electrical one line diagram for the installed air conditioning system in the wheelhouse. Until the system has received approval, it cannot be activated and must remain locked out/tagged out.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2024 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 8 October 2024No resolution recorded
A weight and moment history of changes to the vessel since approval of its lightweight characteristics (displacement, Longitudinal Center of Gravity (LCG) and Vertical Center of Gravity (VCG)) must be maintained. All weight modifications to the vessel (additions, removals, and relocations) including a calculation of the aggregate weight change (absolute total of all additions, removals, and relocations) must be recorded in the history, along with a description of the change(s), when and where accomplished, moment arms, etc. After each modification, the lightweight characteristics must be recalculated. Provide the aggregate weight change of the newly installed wheelhouse air conditioning system to ABS to determine any lightship characteristic changes to the currently issued stability letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2024 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 23 May 2024Resolved
Except as provided in paragraphs (d)(2) through (4) of this section, each towing vessel must carry the survival craft specified in Table 141.305 of this section, as appropriate for the towing vessel, in an aggregate capacity to accommodate the total number of individuals onboard. MI observed that one of the two inflatable bouyant apparatus' had been removed for servicing. The vessel is limited to no more than 08 persons on board until the IBA has been reinstalled on the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2024
Resolution: Operator provided objective evidence that the missing IBA has been re-installed on the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 June 2023Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. The two enclosed 110V outlets at the aft deck, mounted port and starboard to the house, are heavily corroded and ungrounded.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 20 July 2023
Resolution: Replaced both outlets.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 September 2018Resolved
Vsl is broadcasting invalid IMO #
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 October 2018
Resolution: While running a query in VIVS, all information had been updated and AIS was broadcasting the proper information.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.