MAURY USCG vessel records
← All vessels

JEWEL OF THE SEAS

JEWEL OF THE SEAS is a 2004 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2016, most recently in March 2026, along with 33 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 7 March 2026.

Built
2004
Last inspected
7 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 March 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9228356
695733
Flag
BAHAMAS, THE
Maury page id
psix-695733

Documentation record

Tonnage as PSIX records it90090 - Convention (Subpart B), Gross Ton
56328 - Convention (Subpart B), Net Ton
7400 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

7 March 2026 COC-CVE Quarterly · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8314293
11 January 2026 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8294369
11 January 2026 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8345324
4 September 2025 PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8226783
28 April 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8121380
1 March 2025 PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8084415
23 September 2024 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8007973
7 September 2024 COC-CVE Annual · PSC A
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7994509
16 March 2024 PSC B · Deficiency Check · COC-CVE Quarterly
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7876636
13 October 2023 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7808244
14 September 2023 PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7790425
12 August 2023 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7766397
7 August 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7763842
24 April 2023 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7674576
1 January 2023 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7615174
6 November 2022 COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7587499
23 January 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7384423
14 November 2021 PSC A · Deficiency Check · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7348883
8 November 2021 Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 7347570
17 November 2018 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6579166
19 November 2017 Ballast Water Examination · ISPS III Exam · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6305679
4 December 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6050109
18 November 2016 ISPS III Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6041211
6 March 2016 COC-CVE Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5827712

Deficiency record · 33

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 March 2026 Resolved
OPENINGS SHALL BE PROVIDED WITH PERMANENTLY ATTACHED OF MEANS OF CLOSING WHICH SHALL BE AT LEAST AS EFFECTIVE FOR RESISTING FIRES AS THE DIVISIONS IN WHICH THEY ARE FITTED. PSCO FOUND A B-15 FIRE DOOR #FD-02-02-004 IN THE MEDICAL FOR WHICH THE LOCK HAS BEEN REMOVED, COMPROMISING THE B-15 BOUNDARY PROTECTION. 74SOLAS(2001)II-2/30.1 16AB
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2026
Resolved 7 March 2026
Resolution: Verified repairs prior to departure.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 March 2026 Resolved
FIRE DOORS IN MAIN VERTICAL ZONE BULKHEADS AND STAIRWAY ENCLOSURE SHALL SATISFY THE FOLLOWING REQUIREMENTS: THE DOORS SHALL BE SELF CLOSING AND BE CAPABLE OF CLOSING AGAINST AND ANGLE OF INCLINATION OF UP TO 35 DEGREES OPPOSING CLOSURE. PSCO FOUND MAGNETIC SELF CLOSING FIRE DOOR #FSD-10-6-002 OBSTRUCTED BY A HOUSEKEEPING CART, AND PREVENTING THE DOOR FROM CLOSING IF REMOTE OPERATED.
Action required: 10 - Deficiency Rectified
Resolved 7 March 2026
Resolution: PSCO verified correction prior to departure.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 11 January 2026 Resolved
During vessels transit to Crown Bay, vessel expierenced a loss of main power. After two minutes, power had been completely restored, allowing vessel to utilize all pods and thrusters and continue to berth and safely moor. A corrective action plan must be submitted addressing the issue that caused the vessel to lose power and a risk analysis with mitigating factors for departure of port if the issue cannot be identified and corrected. 33 CFR 160.111 (c)
Action required: 17 - Rectify deficiencies prior to departure
Due 11 January 2026
Resolved 11 January 2026
Resolution: Vessel discovered the root of the problem being a faulty vibration sensor on their number 2 gas turbine. Sensor was replaced and tested.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 September 2025 Resolved
Doorways and corridors and intermediate landings included in the means of escape shall be sized in the same manner as stairways. Shall not be less than 900 mm in clear width, the minimum clear width shall be increased by 10 mm for every one person provided in excess of 90 persons. There was a wheelchair outside cabin number 9580, blocking means of escape. 74 SOLAS 01 II-2/28.1.5.3
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2025
Resolution: The wheelchair outside the cabin number 9580 was removed by crew and corridor was cleared.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 September 2025 Resolved
For determining the appropriate fire integrity standards applied between division... (10) PSCO observed combustibles stored in AC spaces adjacent the following fire doors 10-2-009, and in AC room 6-12. 74 SOLAS 01 II-2 / 27.2.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2025
Resolved 11 September 2025
Resolution: Boxes were stored for immediate use in maintenance and removed. Fire suppression system exists to the satisfactory of DNV
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 September 2025 Resolved
Within the perimeter of such stairways enclosures, only public toilets, lockers of non-combustible material providing storage for non-hazardous safety equipment and open information counters are permitted. On numerous decks throughout the ship including the aft stairwell decks 12, 11, 10, 9, 7, 6, PSCO observed trash cans and hand sanitizers stored in stairwell enclosures. 74 SOLAS 01 II-2 / 29.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2025
Resolved 11 September 2025
Resolution: All guest elevator/staircase landings have been cleared of trash bins and hand sanitizers.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 September 2025 Resolved
The constructions of all doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that the bulkheads in which the doors are situated. Such doors and door frames shall be constructed of steel or other equivalent material. PSCO observed the following fire doors did not latch close when released to form a fire boundary: FSD-12-5-004, FSD-11-7-009, FSD-11-4-002. 74 SOLAS 01 II-2 / 30.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2025
Resolved 11 September 2025
Resolution: The fire doors FSD 12-5-004, FSD 11-7-009, and FSD 11-4-002 were adjusted, tested with satisfactory result, and latching properly
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 September 2025 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. The uniform rate of closure for sliding fire doors shall be of no more than 0.2 m/s and no less than 0.1 m/s. PSCO observed the following hinged fire doors entering the machinery space to close quicker than 10s from the beginning of movement: FSD-01-6-020 and FSD-01-6-008. 74 SOLAS 01 II-2 / 30.4.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2025
Resolved 11 September 2025
Resolution: The fire doors FSD 01-6-020 and FSD 01-6-008 were adjusted by the crew, tested and the fire doors were closing within the limits (not leess than 10s and not more than 40s)
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 September 2025 Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. Such doors and door frames shall be constructed of steel or other equivalent material. PSCO observed A-60 door FSD-00-3-003 would not prevent the passage of smoke as air was coming through with the door fully latched shut. 74 SOLAS 01 II-2 / 30.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2025
Resolved 11 September 2025
Resolution: The fire doors FSD 00-3-003 was adjusted by the crew, tested and found in order.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 September 2025 Resolved
All waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. PSCO observed plastic trash cans and plastic bags storing combustible garbage in the following locations: in the shipshape manager's office and in the galley on deck 12 adjacent to fire screen door 12-6-008. 74 SOLAS 01 II-2 / 18.5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2025
Resolved 11 September 2025
Resolution: The combustible material was removed form the indicated locations. Training conducted with galley team.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 4 September 2025 Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use. Several stairway guides were not familiar with the proper use or identification of a manual call point.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 5 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 September 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Lifeboat # 15's emergency steering was inoperable, the arrangement were in such a way that connection of the tiller was not possible. 74 SOLAS 20 III / 20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 September 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 September 2024 Resolved
Doorways and corridors and intermideiate landings included in the means of escape shall be sized in the same manner as stairways. Shall not be less than 900 mm in clear width, the minimum clear width shall be increased by 100 mm for every one person provided for in excess of 90 persons. Storage of hand sanitizer and various shipboard items on Deck 2 – MVZ 5, deck 5 – MVZ 6 and deck 3 – MVZ 1 restricted ability for egress below required minimum width of a stairway (900 mm) – 74 SOLAS (01) II-2/28.1.5.3. – Code 07120 – Action 17C.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2024
Resolution: Ship personnel removed the items blocking egress.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 September 2024 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and satirway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 seconds and no less that 10 seconds from the beginning of their movement. During testing, the following 14 hinged fire doors were not closing within the allowed time from of 10-40 seconds: 02-1-016, 03-7-017, 03-5-014, 04-5-002, 04-7-007, 04-7-005, 07-3-001, 09-6-001, 11-3-012, 11-3-006, 11-7-007, 11-7-000, 11-7-012, 13-5-011. – 74 SOLAS (01) II-2/30.4.2 – Code 07105 – Action 16ac.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2024
Resolution: Received class report attesting to adjustments to closing devices of fire doors resulting in satisfactory operational test.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 September 2024 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the prupose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. In the Solarium electrical room, a Category 10 space on Deck 11, PSCO observed storage of boxes of combustible materials which is prohibited. 74 SOLAS (01) II-2/26.2.2 – Code 07101 – Action 10c.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 7 September 2024
Resolution: Ship's personnel removed the boxes.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 September 2024 Resolved
The bulkhead deck or a deck above it shall be weather tight. All openings in the exposed weather deck shall have coamings of ample height and strength and shall be provided with efficient means for expeditiously closing them weather tight. The weather tight door (04-07-06) leading to the ship’s CO2 room was found to be missing the bottom portions of its gasket. 74 SOLAS (04) II-1/20.2 – Code 03107 – Action 10c.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 September 2024
Resolution: Ship's personnel replaced gasket.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 September 2024 Resolved
The activation of any detector or manually operated call point shall initiate a visual and audible fire signal at the control panel and indicating units. If the signals have not received attention within 2 minutes an audible alarm shall be automatically sounded throughout the crew accomodation and service spaces, control stations and machinery spaces of category A. Manual call point, 30.05.39.031 was found not operational when tested. 74 SOLAS (01) II-2/13.1.4 – Code 07106 – Action 10c.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 September 2024
Resolution: Ship's personnel repaired the manual call point. PSCO verified proper operation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 March 2024 Resolved
Fire-extinguishing appliances shall be kept in good order and be available for immediate use at all times. Vessel renewed all portable fire extinguishers on board and did not secure all extinguishers to their respective brackets rendering thme prone to movement and damage underway. 74 SOLAS (01) II-2/21
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2024
Resolved 19 March 2024
Resolution: Received multiple pictures, and a class survey statement that all portable fire extinguishers have been secured to its approved bracket. See documents for class report.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 March 2024 Resolved
Doorways and corridors and intermediate landings included in the means of escape shall be sized in the same manner as stairways. Shall not be less than 900 mm in clear width. Watertight door 02-7-01 and 01 emergency escape door from the engine room were obstructed with boxes and moving carts rendering it less than 900 mm in clear width. 74SOLAS(01)II-2/28.1.5.3 Code 10C.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 16 March 2024
Resolution: Boxes have been removed prior finishing the exam.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 September 2023 Resolved
The approximate time of closure for hinged fire doors shall be no more than 40s and no less than 10s from the beginning of their movement... FSD's 8-4-001, 7-4-07, 7-4-005, 7-7-001, and 7-7-004 closed too fast. FSD's 11-5-003, 03-7-009 failed to close. 74 SOLAS (01) II-2/30.4.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2023
Resolved 8 January 2024
Resolution: Def was never entered. During review of casework def was closed due to time elapsed since def was issued.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 January 2023 Resolved
The JEWEL OF THE SEAS failed to submit an NOA prior to departure but at least 24 hours before arriving at the port or place of destination for a voyage less than 96 hours.
Action required: 10 - Deficiency Rectified
Due 1 January 2023
Resolved 9 January 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 6 November 2022 Resolved
11101 - Life Saving Appliances - Passenger ships engaged on international voyages which are not short voyages shall carry a totally enclosed lifeboat complying with the requirements of section 4.6. PSCO observed a broken glass panel in the aft portion of Lifeboat #10. 74 SOLAS (20) III/21, 10c 74 SOLAS 20 III/21
Action required: 10 - Deficiency Rectified
Due 6 November 2022
Resolved 6 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 November 2021 Resolved
ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO INSTALLED AS NOT TO CAUSE INJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER. PSCO FOUND SWITCHBOARD DOORS FOR CORAL THEATER BEHIND B-04-2-054 DO NOT CLOSE AND SWING FREELY OR REMAIN IN THE OPEN POSITION. SOLAS(04) II-1/45.1.3 16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 November 2021
Resolution: RECIEVED CLASS REPORT ATTESTING TO THE REPAIR OF THE LATCHING MECHANISM OF SWITCHBOAD DOORS.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 November 2018 Resolved
The purpose of means of escape is to provide means for persons onboard to safely and swiftly escape to the life boats and life raft embarkation deck. Escape routes shall be maintained in a safe condition and free of obstacles. While conducting the walkthrough of accommodation spaces PSCOs identified the door between he crew mess and crew bar aft was sealed with masking tape on either side as a means to prevent the passage of smoke. Additionally, a football table was found blocking the escape route at the kids disco "Fuel"
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 17 November 2018
Resolution: The vessel removed the masking tape and football table.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 November 2018 Resolved
Each electrical circuit shall be protected against overload. The computer room on Deck 7 was noted having 4 electrical power strips that were continuously connected to each other.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 17 November 2018
Resolution: The vessel disconnected the power strips from one another.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 November 2018 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. Structural fire protection, including fire resistant divisions, and protection of openings and penetrations. The vessel's crew drilled holes through the bulk head in the smoke extraction fan room on Deck 17. Without reinstalling structural fire protection, leaving a section of the bulkhead un-insolated.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 17 November 2018
Resolution: The vessel replaced structural fire protection.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 November 2016 Resolved
The construction of doors in “A” class divisions shall provide resistance to fire as well as to the passage of smoke and flame. PSCO found the following doors which would not close: B-05-02-008, B-05-02-005, FD-04-1-013, and FD-06-7-001. The following hose ports would not close on the following fire screen doors: FD-11-7-010, FD-11-4-001, FD-06-6-007, and FD-06-6-006. SOLAS (2001) II-2/9.4.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2016
Resolved 4 December 2016
Resolution: Received class report and verified on board that all doors and hose ports will now close.
Construction/Loadline › Structures › Door
Issued 18 November 2016 Resolved
All access openings in bulkheads shall be fitted with doors of steel and weathertight when closed. PSCO found Deck five (5) port side aft door to galley could not be closed. ICLL 1966 Annex I Reg 12(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 18 November 2016
Fire Fighting › Means of Escape › Blocked
Issued 18 November 2016 Resolved
Escape routes shall be maintained in a safe condition and clear of obstacles. PSCO found the forward escape exit in the Concierge lounge (D13, MVZ 5) blocked by a table and chairs. SOLAS (2001)/ 28.1.1.2
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 18 November 2016
Fire Fighting › Means of Escape › Blocked
Issued 18 November 2016 Resolved
Escape routes shall be maintained in a safe condition and clear of obstacles. PSCO found (D11, MVZ 2) in the spa area that the doors at frames 242 and 252 in both the mens and the womens shower rooms were fitted with locks that created a dead end corridor. SOLAS (2001) II-2/28
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 18 November 2016
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 18 November 2016 Resolved
In addition to complying with the specific provisions for fire integrity of all the bulkheads and decks of passenger ships the minimum fire integrity of all bulkheads and decks shall be prescribed in the table 26.1 and 26.2. PSCO found art that was being stored in the golf simulator space on deck 12 which is listed as a category 7 space on the Fire Control plan vice category 13.SOLAS(2001)II-2/26
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 December 2016
Resolved 4 December 2016
Resolution: Received class report and went onboard to verify that the space had been emptied.
Fire Fighting › Fire Hoses › Connections
Issued 18 November 2016 Resolved
Fire hoses in interior locations in passenger ships carrying more than 36 passengers shall be connected to the hydrant at all times. PSCO found five (5) hoses not connected at various locations throughout the vessel. SOLAS (2001) II-2/7.1
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 18 November 2016
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 18 November 2016 Resolved
All waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. PSCO found in the Crew Galley, Main Galley, and Garbage Room multiple plastic waste receptacles used for cloth towels, wooden hangers, and dry paper trash. SOLAS (2001)II-2/18.5
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 18 November 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.