No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 October 2017
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9113147
438312
Flag
NORWAY
Maury page id
psix-438312

Documentation record

Tonnage as PSIX records it28337 - Convention (Subpart B), Gross Ton
13767 - Convention (Subpart B), Net Ton
56931 - Displacement, Ton
46632 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 8 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

24 October 2017 MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex II Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6291864
10 August 2017 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6236132
7 August 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6233323
31 July 2017 COC-CHEM & TVE Annual · Deficiency Check · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6226350
2 May 2017 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6138071
9 September 2016 ISPS III Exam · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5999018
13 June 2016 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5906294
24 May 2016 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew · PII Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5876380

Deficiency record · 6

Fire Fighting › Fixed Deck Foam System › Monitors
Issued 2 May 2017 Resolved
Every ship shall be provided with a fixed deck foam system in accordance with the requiremetns of 11.3.2 to 11.3.12. Vessel could not produce documentation attesting to the fire resistance fo FRP grating used to access/operate fire monitors. IBC Ch11/11.3.1. 40A/C
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 August 2017
Resolution: Determined through documentation and visual inspection that appropriate grating was installed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 May 2016 Resolved
01-0899 Other (accid. prevent.)-Efficient guard rails and bullworks shall be fitted to all exposed parts of the freeboard and superstructure decks. Lower rail on the port side aft guard rail is broken due to weathering and damage. ICLL 66 Reg 25.2 40ac
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 June 2016
Resolved 13 June 2016
Resolution: Lower guard rail repaired and rewelded back in place.
Deck/Cargo › Inert Gas System › Scrubber Tower
Issued 24 May 2016 Resolved
02-1899 Other(tankers)-After any survey of the ship under regulations 6,7,8,9, or 10 of this chapter has been completed, no change shall be made in the structural arrangement, machinery, equipment and other items covered by the survey, without the sanction of the administration. Multiple pinhole leaks were discovered on the scrubber tower and piping. 74SOLAS1997 Cons. I/11b 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 June 2016
Resolved 13 June 2016
Resolution: Scrubber cooling pipe line cropped out and renewed from flange to flange.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 24 May 2016 Resolved
03-2199 Other (MARPOL operational Def.)-Each device must be free of defects that would allow toxic substances to escape to the interior of the vessel. The vessel's MSD has two holes in the tank which allows fumes to be released into the engine room. 33CFR159.95(a)(1) 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 June 2016
Resolved 13 June 2016
Resolution: Marine sanitation device's sewage tank plating repaired and brought in order.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 24 May 2016 Resolved
04-1499 Other(Prop. & Aux. Machinery)-After survey of the ship...no change shall be made in the structural arrangement, machinery, equipment and other items covered by the survey, without sanction of the administration. Soft patch temporary repairs were found on the #2 cargo pump cooling line and the #2 general service pump line. 74SOLAS 1997 Cons. I/11b 40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 June 2016
Resolved 13 June 2016
Resolution: No. 2 cargo pump cooling line and the No. 2 general service pump pipings were cropped out and completely renewed.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 24 May 2016 Resolved
05-1499 Other (Prop. & Aux. Machinery)-After any survey of the ship...no change shall be made in the structural arrangement,machinery, equipment and other items covered by the survey, without the sanction of the administration. Drain valve for the incinerator fuel supply tank is leaking due to faulty seal. 74SOLAS 1997 Cons. I/11b
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 June 2016
Resolved 13 June 2016
Resolution: Drain valve repaired and gasket replaced, and door insulation castable refractories brought in order.