MAURY USCG vessel records Sign in
← All vessels

CHAMPION CORNELIA

CHAMPION CORNELIA is a 1996 tank ship. The Coast Guard has recorded 68 inspections since 1996, most recently in October 2017, along with 26 deficiencies and 11 operational controls.

Records from 1996 to 2017. Most recent: inspection, 24 October 2017.

Built
1996
Last inspected
24 October 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9113147 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
438312
Flag
NORWAY
—
Maury page id
psix-438312

Inspections, by type

…with no type recorded37
Years with a record 18 calendar years (1996–2017)
The 68 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28337 - Convention (Subpart B), Gross Ton
13767 - Convention (Subpart B), Net Ton
56931 - Displacement, Ton
46632 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BERNIE BRIERE Tank Barge · MISLE 949515 · 30 December 2010 · activity 3918076FREEDOM Towing Vessel · MISLE 609006 · 5 April 2005 · activity 2328338LIBERTY Towing Vessel · MISLE 623727 · 5 April 2005 · activity 2328338LADY KIM Commercial Fishing Vessel · MISLE 160496 · 7 October 1999 · activity 3568WALLABOUT BAY Tank Barge · MISLE 277568 · 17 April 1996 · activity 504171

Inspection history · 68

24 October 2017 MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex II Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6291864
10 August 2017 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6236132
7 August 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6233323
31 July 2017 COC-CHEM & TVE Annual · Deficiency Check · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6226350
2 May 2017 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6138071
9 September 2016 ISPS III Exam · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5999018
13 June 2016 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5906294
24 May 2016 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew · PII Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5876380
9 November 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5759781
4 November 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5758962
3 November 2015 Deficiency Check · COC-CHEM Renew · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5756791
28 August 2014 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4968537
30 December 2010 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3918076
18 January 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3665592
6 June 2008 ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3228719
22 January 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3134616
13 July 2007 MARPOL Annex I Examination · MARPOL Annex V Examination · MARPOL Annex II Examination · COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2992198
4 October 2006 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2759267
11 September 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2775265
14 August 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2747909
9 August 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2741696
7 August 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2738446
12 June 2006 ISPS III Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2677619
28 March 2006 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2610897
9 December 2005 Ballast Water Examination · Random ISPS/MTSA/PSC · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2548598
14 September 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2492246
16 June 2005 MARPOL Annex I Examination · Ballast Water Examination · COC-TVE Renew · MARPOL Annex V Examination · MARPOL Annex II Examination · Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2392176
5 April 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2328338
12 January 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2274876
11 January 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2278739
10 January 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2269828
10 January 2005 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2272127
6 January 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2270055
14 July 2004 COC-CHEM Annual
Type not classified · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2132942
13 July 2004 ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2131899
29 May 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2081404
23 May 2004 MTSA/ISPS Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2075411
4 April 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2037748
22 September 2003 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1910584
25 June 2003 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1826209
20 May 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1797436
20 March 2003 Security Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1766932
18 February 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1745366
3 October 2002 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1684259
17 June 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1632028
14 June 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1632041
8 April 2002 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1602374
23 June 2001 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 291267
23 June 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1067758
10 July 2000 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 279764
10 July 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1471744
1 May 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 733191
7 October 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 3568
7 October 1999 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1397256
13 August 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 431634
22 January 1999 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 424619
14 January 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 811486
12 February 1998 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 425573
9 February 1998 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 412611
8 February 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1402605
6 February 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 400252
6 February 1997 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1107277
1 February 1997 MARPOL Annex I Examination · Letter of Compliance (Initial/Renewal)
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1102670
19 April 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 390615
17 April 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 182701
17 April 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 504171
4 April 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 389437
4 April 1996 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1080200

Deficiency record · 26

Fire Fighting › Fixed Deck Foam System › Monitors
Issued 2 May 2017 Resolved
Every ship shall be provided with a fixed deck foam system in accordance with the requiremetns of 11.3.2 to 11.3.12. Vessel could not produce documentation attesting to the fire resistance fo FRP grating used to access/operate fire monitors. IBC Ch11/11.3.1. 40A/C
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 August 2017
Resolution: Determined through documentation and visual inspection that appropriate grating was installed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 May 2016 Resolved
01-0899 Other (accid. prevent.)-Efficient guard rails and bullworks shall be fitted to all exposed parts of the freeboard and superstructure decks. Lower rail on the port side aft guard rail is broken due to weathering and damage. ICLL 66 Reg 25.2 40ac
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 June 2016
Resolved 13 June 2016
Resolution: Lower guard rail repaired and rewelded back in place.
Deck/Cargo › Inert Gas System › Scrubber Tower
Issued 24 May 2016 Resolved
02-1899 Other(tankers)-After any survey of the ship under regulations 6,7,8,9, or 10 of this chapter has been completed, no change shall be made in the structural arrangement, machinery, equipment and other items covered by the survey, without the sanction of the administration. Multiple pinhole leaks were discovered on the scrubber tower and piping. 74SOLAS1997 Cons. I/11b 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 June 2016
Resolved 13 June 2016
Resolution: Scrubber cooling pipe line cropped out and renewed from flange to flange.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 24 May 2016 Resolved
03-2199 Other (MARPOL operational Def.)-Each device must be free of defects that would allow toxic substances to escape to the interior of the vessel. The vessel's MSD has two holes in the tank which allows fumes to be released into the engine room. 33CFR159.95(a)(1) 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 June 2016
Resolved 13 June 2016
Resolution: Marine sanitation device's sewage tank plating repaired and brought in order.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 24 May 2016 Resolved
04-1499 Other(Prop. & Aux. Machinery)-After survey of the ship...no change shall be made in the structural arrangement, machinery, equipment and other items covered by the survey, without sanction of the administration. Soft patch temporary repairs were found on the #2 cargo pump cooling line and the #2 general service pump line. 74SOLAS 1997 Cons. I/11b 40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 June 2016
Resolved 13 June 2016
Resolution: No. 2 cargo pump cooling line and the No. 2 general service pump pipings were cropped out and completely renewed.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 24 May 2016 Resolved
05-1499 Other (Prop. & Aux. Machinery)-After any survey of the ship...no change shall be made in the structural arrangement,machinery, equipment and other items covered by the survey, without the sanction of the administration. Drain valve for the incinerator fuel supply tank is leaking due to faulty seal. 74SOLAS 1997 Cons. I/11b
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 June 2016
Resolved 13 June 2016
Resolution: Drain valve repaired and gasket replaced, and door insulation castable refractories brought in order.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 8 November 2015 Resolved
1050 The inert gas system referred to in the chapter II-2 of the convention shall be designed, constructed and tested to the satisfaction of the Admin. It stall be so designed and operated as to render and maintain the atmosphere of the cargo tanks, non-flammable at all times, except when such tanks are required to be gas free. Deficiency is continued in narrative.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 November 2015
Resolved 17 November 2015
Resolution: Issue was given condition of class as per class report submitted 17NOV15
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 November 2015 Resolved
1499 The machinery, boilers and other pressures vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Examiners found several patches throughout the ship. There are 06 patches throughout the OWS and the gate valve overboard is wasted. There are patches on the sewage line.. Deiciency continued on narrative.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 November 2015
Resolved 10 November 2015
Resolution: Issue was given condition of class as per class report submitted 10NOV15.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 6 November 2015 Resolved
1499The machinery, boilers and other pressure vsl associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. There are signs of wastage throughout the incinerator. There are cracks on the top corners of the door and frame is bent in the upper level. In addition there are fire bricks installed..Deficiency continued in narrative
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 November 2015
Resolved 10 November 2015
Resolution: Issue was given condition of class as per class report submitted 10NOV15
Operations/Management › Drills/Instruction › Fire
Issued 4 November 2015 Resolved
2020 Drills shall, as far as practicable be conducted as if there were an actual emergency. During the first drill, fire team was unable to access the accomodation area from outside the sapce due to doors being locked. The ships Master or crew does not have keys on board to unlock each door of the main deck. Deficiency continued in narrative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 8 November 2015
Resolution: Coast Guard Inspector attended vessel and witnessed crew conduct a sastisfactory fire drill.
Fire Fighting › Combustible Materials › Insulation
Issued 4 November 2015 Resolved
1420 The arrangements for the storage, distribution and utilization of flammable oil shall be such as to ensure the safety of the ship and persons onboard. During the PSC examination, oil soaked lagging and excessive oil leaks were found throughout the engine room in the vicinity of the fuel oil service tanks, fuel oil and lube oil purifiers and throughout... Deficiency continued on narrative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 8 November 2015
Resolution: Coat Guard Inspector witnessed replaced lagging on board the vessel and excessive oil leaks were cleared.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 4 November 2015 Resolved
The Oil Record Book Part I shall be completed on each occasion, on a tank to tank basis if appropriate, whenever any of the following machinery space operations take place: ballasting or cleaning of oil fuel tanks, discharge of dirty ballast or cleaning water from oil fuel tanks, collection and disposal of oil residues, discharge overboard or disposal otherwise of bilge water which has accumulate
Action required: 705 - Other - as specified
Due 16 November 2015
Resolved 10 November 2015
Resolution: Issue was given condition of class as per class report submitted 10NOV15
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 22 January 2008 Resolved
Received a report from the vessel that main engine was malfunctioning (attaining not more than half speed).
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2008
Resolution: Received a report from class attesting to the repairs made to the main engine cylinder head #2.
Communications › Internal Communications System › Engine Order Telegraph System
Issued 11 September 2006 Resolved
Provide satisfactory technician's report attesting to proper operation of EOT.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2006
Resolution: Received technician''s report.
Documentation › Manuals/Policy Documentation › Tank Vessel Loading Information
Issued 12 June 2006 Resolved
Vessel does not have approval letter for the Inert Gas System. Vessel is required to obtain Flag State approval for the inert Gas System and send it to the Coast Guard prior to entering U.S Waters and transfering cargo. Rectify defieciencies to the satisfaction of class prior to next U.S port. Solas 74 (amended) Ch II-2 Reg 62.1
Action required: 15 - Rectify deficiencies by next port
Resolved 14 August 2006
Resolution: Cleared by class (DNV) report.
Lifesaving › Launching Appliances › Winch
Issued 12 June 2006 Resolved
Vessel's rescue boat cannot recover with in 5 minutes. Repair winch to rescue boat to the satisfaction of class prior to next U.S. port after sailing foreign. Solas 74/78 (2004) Ch III Reg 17.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 August 2006
Resolution: Cleared by class (DNV) report.
Lifesaving › Launching Appliances › Winch
Issued 12 June 2006 Resolved
ENTERED BY MISSTAKE.
Due 12 June 2006
Resolved 12 June 2006
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 9 December 2005 Resolved
Provide for tech report attesting to readiness status of vessels fixed combustible gas indicator unit (vimex). Found unit indicating high level alarms in all areas that were sampled, even though unit was showing 0% LEL readings at times. To the satisfaction of vessels administration.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 December 2005
Resolution: Rceivied faxed confirmation from vsls marine superintendent [name withheld], that def heas been corrected and a non-conformity was sent to company rep.
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 January 2005 Resolved
Starboard side (secondary) radar screen was not functioning properly. The top of the screen was distorted and could possibly result in overlooking contacts in certain areas.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2005
Deck/Cargo › Inert Gas System
Issued 3 October 2002 Resolved
IGS non-return valve and possibly deck main isolation valve not operating properly. Cargo vapors were observed coming from vent between deck seal and non-return valve. Overhaul/repair valve(s) prior to loading next cargo requiring inert gas.
Action required: 705 - Other - as specified
Due 18 October 2002
Resolved 9 October 2002
Resolution: Both valves repaired. Proper documentation recvd from Class. JJD
Deck/Cargo › Inert Gas System
Issued 3 October 2002 Resolved
Vent/valve (#47) on IGS drawings does not match physical placement of same. Correct drawing.
Action required: 705 - Other - as specified
Due 18 October 2002
Resolved 9 October 2002
Resolution: Valve moved to proper location & now matches drawing. Proper documentation recvd from Class. JJD
Navigation › Collision/Grounding Avoidance
Issued 17 June 2002 Resolved
Vsl was issued a Letter of Deviation to enter the Port of Corpus Christi with an inoperable echo depth recording device (33 CFR 164.35(i)). LEGACY COMPONENT DESC: Echo-sounding Device Recorder
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2002
Resolution: Received tech report stating device is operable.
Navigation
Issued 23 June 2001 Resolved
THE PRIMARY RADAR DOES NOT OPERATE PROPERLY._x001C_
Condition: Unknown
Due 24 June 2001
Resolved 26 June 2001
Documentation
Issued 23 June 2001 Resolved
SEVERAL DISCREPANCIES WERE FOUND WITH THE ACCURACY AND CORRECTNESS OF THE FOLLOWING: IOPP CERTIFICATE, CERTIFICATE OF FITNESS, P & A MANUAL, IOPP NLSCERT. DIFFERENCES BETWEEN EACH ITEM ARE ASSOCIATED WITH AUTHORIZED CARGOESFOR CARRIAGE. SEE PSNS FOR DETAILS.
Condition: Unknown
Due 25 June 2001
Resolved 5 July 2001
Navigation
Issued 1 February 1997 Resolved
Repair and prove proper operation of gyro compass repeater in after steering compartment prior to departure. If unable to repair, request ltr of deviation and make repairs at next US port call.
Condition: Unknown
Due 1 February 1997
Resolved 1 February 1997
Deck/Cargo
Issued 1 February 1997 Resolved
Make pumproom available for inspection by CG inspector at next US port callby having space certified safe for workers by a certified marine chemist.
Condition: Unknown
Due 1 February 1997
Resolved 1 February 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.