MAURY USCG vessel records
← All vessels

ADVENTURESS

ADVENTURESS is a 1913 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 2016, most recently in October 2025, along with 12 deficiencies and 3 casualty investigations between 2008 and 2025.

Records from 2008 to 2025. Most recent: inspection, 1 October 2025.

Built
1913
Last inspected
1 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 October 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ8518
Flag
UNITED STATES
Maury page id
psix-41729

Documentation record

Registered dimensions (L × B × D)85.5 ft × 21.4 ft × 9.8 ft
Registered tonnagegross 82 / net 73
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRICE BROTHERS · EAST BOOTHBAY, ME, UNITED STATES · built 1913
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 22 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Regulatory (Subpart C or D), Gross Ton
73 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

32 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; 3 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 32

1 October 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8245080
1 August 2025 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8199950
1 August 2025 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8218021
18 March 2025 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8100247
6 January 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8059075
16 September 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8001884
9 May 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7910054
1 December 2023 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7833464
20 November 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7828350
11 October 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7810367
28 February 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7656566
20 December 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7612361
6 December 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7605234
21 September 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7563927
17 August 2022 Plan Review "T" Boat
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7596727
20 July 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7512293
18 March 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7414343
30 September 2021 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7317278
10 February 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7140115
27 October 2020 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7085452
20 October 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7083945
3 January 2020 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6882467
4 October 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6824946
11 September 2019 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6809168
11 September 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6533406
20 July 2018 Drydock Exam · Internal Structural Exam · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6564670
2 May 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6404231
24 January 2018 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6343307
6 October 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6282641
3 April 2017 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6132516
27 September 2016 COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6006278
1 June 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5894044

Deficiency record · 12

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 August 2025 Resolved
The owner or builder shall submit for approval by the Officer in Charge of Marine Inspections, of the inspection zone where the vessel is to be inspected, at least one copy of each of the following plans: (6) Electrical installation. The vessel was unable to produce a line diagram with adequate detail. 46 CFR 177.05-1(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2025
Resolved 1 October 2025
Resolution: Ship's master provided line diagram of electrical installation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 August 2025 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will results in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment and reasonable safe from electrical shock from personnel. Vsl experienced smoke emanating from E/R causing loss of AC power. 46CFR183.01-5
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2025
Resolution: Vessel replaced Inverters
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 September 2024 Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. One life ring (Port side aft) damaged and needs to be replaced. 46CFR189.70(aq)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2024
Resolved 19 September 2024
Resolution: Life ring and line replaced.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 September 2021 Resolved
No smoke detector in Capt and Crew Cabin. Provide proof of installation prior to the carriage of overnight passengers. 46 CFR 181.405(c)
Action required: 705 - Other - as specified
Resolved 4 October 2021
Resolution: Installed detectors in Capt and Crew cabin.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 30 September 2021 Resolved
Not able to test Bilge suction in Engine Room and Focsle. Need proof of operation. 46 CFR 176.804(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2021
Resolution: Recieved videos proving bilge suction operation.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 10 October 2017 Resolved
Fire extinguisher number 8 under main companion way latter indicates recharge necessary. Replace, recharge, or permanently remove extinguisher. 46 CFR
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 11 April 2018
Resolution: Fire extinguisher replaced
Engineering › Fuel Oil Service System › Hose
Issued 10 October 2017 Resolved
Fuel supply and return lines on auxilary generator are single hose clamped. Provide double hose clamps on both ends of hoses. 46 CFR 182.720(e)(3)(v)(B)
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 11 April 2018
Resolution: hoses properly clamped following engine replacement
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 10 October 2017 Resolved
Aft ring buoy found with improper battery and o-ring gasket in water light. Replace with approved water light battery and gasket. 46 CFR 180.70(d)(1)
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 11 April 2018
Resolution: Entire waterlight replaced
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 September 2016 Resolved
Focsle lifevest storage was not marked. Label focsle lifevest storage container with number of lifevests inside.
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 20 October 2016
Resolution: Added stowage label.
Documentation › Certificates/Documents › Permit, Other
Issued 27 September 2016 Resolved
Master did not have marine radio operator permit. Provide proof of marine radio operator permit.
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 20 October 2016
Resolution: Provided proof of permit to Marine Inspector
Engineering › Fuel Oil Service System › Hose
Issued 27 September 2016 Resolved
Serveral fuel hoses are over 30 inches long and are not SAE J1942 hoses, with J1475 fittings. Install required hoses.
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 3 April 2017
Resolution: All required fuel hoses replaced, all sat.
Construction/Loadline › Structures › Deck Plating
Issued 27 September 2016 Resolved
Lazarette hatch on deck is nto watertight (flush with deck). Install water tight hatch.
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 3 April 2017
Resolution: Replaced hatch with watertight hatch, conducted chalk test. All sat.

Casualty record · 3

23 June 2008Routine · role: Involved in a Marine Casualty · activity 3252646
9 May 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7910054
1 August 2025Routine · role: Involved in a Marine Casualty · activity 8218021
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.