Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 January 2019
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9110107
418755
Flag
PANAMA
Maury page id
psix-418755

Documentation record

Tonnage as PSIX records it13739 - Convention (Subpart B), Net Ton
15181 - Dead Weight, Ton
27778 - Displacement, Ton
45796 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

12 January 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6608508
10 January 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6608819
22 July 2018 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6482259
14 January 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6334713
5 July 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6192508
19 June 2017 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6181134
19 June 2017 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6183030
1 February 2017 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6081055
4 January 2017 NPV Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6064196
6 August 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5963735
6 August 2016 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5963803
1 July 2016 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5925865
22 June 2016 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5913053
18 June 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5907938
1 April 2016 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5845248

Deficiency record · 16

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 July 2018 Resolved
Each life jacket shall have an operable light. 3 life jacket lights were found inoperable by the aft six-person life raft. 74SOLAS(97)III/32.3.1.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 July 2018
Resolved 22 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 22 July 2018 Resolved
Each personal life-saving appliance shall be rot-proof, not unduly affected by fungal attack, and be fitted with retro reflective tape. One immersion suit was found immersed in water and in a deteriorated state with retro coming off. 74SOLAS(97)III/30.2.4,.7
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2018
Resolved 24 July 2018
Resolution: Vessel provided proof of new immersion suit.See documents.
Construction/Loadline › Hull › Hull Plating
Issued 19 June 2017 Resolved
SOLAS 74(a) I/11(a) - Condition of ship and equipment shall be maintained to conform with the present regulations at all times to ensure the ship will remain fit to proceed to sea. SECMD-NCR received report that vessel struck and sank buoy #7 in Port of Baltimore.
Due 19 June 2017
Resolved 21 June 2017
Resolution: Recieved class report clearing deficiencie
Electrical › Electric Generation Source (emergency) › Panelboard
Issued 4 January 2017 Resolved
-1499 -After any survey of the ship has been completed no change shall be made in the structural arrangement covered by the survey. PSCO discovered an unauthorized installation of a deck compressor to the emergency generator panel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 1 February 2017
Resolution: Received class report testifying to proper removal of compressor. See class report in documents for more information.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 January 2017 Resolved
-0830 -All electrical cables and wires external to equipment shall be at least of a flame -retardant type and shall be so installed as not to impair their original flame-retardant properties. -PSCO found multiply areas of exposed wires and wires wrapped in electrical tape on the main diesel engine on the solenoid for the fuel oil shut-down device on generator 2 and 3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2017
Resolved 1 February 2017
Resolution: Received repair report from class testifying to proper repair of all exposed electrical hazards. See class report in documents for more information.
Engineering › Steering Gear System › Power Unit
Issued 4 January 2017 Resolved
-0936 -Hydraulic power-operated steering gear shall be provided with ... a fixed storage tank having sufficient capacity to recharge at least one power actuating system including the reservoir, where the main steering gear is required to be power-operated. -PSCO discovered that the steering gear reservior did not have sufficient hydraulic fluid to recharge primary tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2017
Resolved 4 January 2017
Resolution: Deficiency rectified on the spot.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 18 June 2016 Resolved
0715- Detection-The fire detection and alarm system shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO observed the fire detection panel displaying several faults and multiple smoke detectors failed to detect smoke and sound the alarm when tested. No Recognized Organization Condition of Class or notifications to Class Society were made.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 June 2016
Resolution: Vessel received condition of class for replacement of smoke detectors witha due date of 19JUL2016. See attached Class Report.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 18 June 2016 Resolved
2500-ISM related deficiencies-The Safety Management System shall be maintained in accordance with the provisions of the International Safety Management Code. PSCO observed the following ISM non conformities; As per the vessels SMS, It is the Masters, senior officers and the crew members responsibility to report all non-conformities to their supervisors. The fire panel has 19 faults, see narrative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 June 2016
Resolution: Reviewed and validated class report attesting to proper repair of deficiency. See attached Class Reports.
Engineering › Diesel Engine (propulsion-electric) › Cylinder
Issued 18 June 2016 Resolved
0999-Other(Safety in General)-The arrangements for the utilization and the storage of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed excessive fuel oil continuously leaking from the number three cylinder fuel oil pump puncture valve. 74 SOLAS (81 Amend) CH II-2 / 15.2 (17 a,c 10c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 June 2016
Resolution: Vessel crew replaced the puncture valve in its entirety to prevent further leaks
Engineering › Fuel Oil Service System › Piping
Issued 18 June 2016 Resolved
0999-Other(Safety in General)-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed the six inch fuel oil overflow pipe connecting the two service tanks in the engine room, see narrative
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 June 2016
Resolution: Reviewed and validated class report attesting to proper repair of deficiency. See attached Class Report.
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 18 June 2016 Resolved
0999-Other(Safety in General)-The arrangements for the utilization and the storage of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed multiple containments full of oil and oil soaked rags throughout the engine room. 74 SOLAS (81 Amend) CH II-2 / 15.2 (17 a, c)
Action required: 705 - Other - as specified
Resolved 21 June 2016
Resolution: Reviewed and validated class report attesting to proper repair of deficiency. See attached Class Report.
Accommodation/Occupational Safety › Ventilation › General
Issued 18 June 2016 Resolved
0999-Other(Safety in General)-Means shall be provided to indicate any loss of the required ventilation capacity on the navigation bridge. PSCO observed the cargo ventilation indicators on the bridge were non-operational. No Recognized Organization Condition of Class or notifications to Class Society were made. 74 SOLAS (81 Amend) CH II-2 / 37.1.6.3 (17 a,c)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 21 June 2016
Resolution: Vessel received condition of class for malfunctioning ventilating panel. Due date of 19JUL2016 for repairs. See attached Class Report.
Engineering › Steam System (auxiliary) › Piping
Issued 18 June 2016 Resolved
1499-Other(Prop. & Aux. Machinery)-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed multiple leaks and temporary repairs on the boiler system. No Recognized Organization, see narrative
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 June 2016
Resolution: Reviewed and validated class report attesting to proper repair of deficiency. See attached Class Report.
Engineering › Diesel Engine (propulsion-direct drive) › Waste Heat Recovery
Issued 18 June 2016 Resolved
1410-Propulsion main engine-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed a hot spot on the Main Engine Gas Outlet Casing. 74 SOLAS (14 Cons.) CH I/ 11(a) (17 a,c)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 21 June 2016
Resolution: Reviewed and validated class report attesting to proper repair of deficiency. See attached Class Report.
Fire Fighting › Fire Hydrants › Condition
Issued 18 June 2016 Resolved
0720-Fire fighting equipment-Fire extinguishing systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed two fire hydrants in the engine room with frozen valves and outlet caps. A hammer was needed to free the outlet caps and a large tool was needed to free the valve wheel. 74 SOLAS (14 Cons.) CH II-2/ 14.2.1.2 (10 c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 June 2016
Resolution: Vessel crew rectified the condition of the fire hydrants.
Fire Fighting › Fire Hoses › Connections
Issued 18 June 2016 Resolved
0730-Appliances(general equipment)-Hoses specified in this chapter as "fire hoses" shall together with any necessary fittings and tools be kept ready for use. PSCO observed two hose stations in the engine room without spanner wrenches. 74 SOLAS (81 Amend) CH II-2/ 4.7.1 (10 c)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 June 2016
Resolution: Vessel crew supplied spanner wrenches to proper locations.

Ownership record