Records from 1985 to 2007. Most recent: operational control imposed, 2 July 2007.
Documentation › Certificates/Documents › Stability Letter
Issued 19 April 2007
Resolved
Provide stability letter onboard vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 19 April 2007
Resolved
Provide Senior Deckhand letter onboard vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 19 April 2007
Resolved
Provide proof of enrollement of crew members in drug testing program in accordance with 46 CFR Part 16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2007
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 19 April 2007
Resolved
Provide emergency instructions IAW 46 CFR 185.25-5.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Communications › Public Address System › Loudspeaker
Issued 19 April 2007
Resolved
Prove proper operation of Public Address System IAW 46 CFR 120.430.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 April 2007
Resolved
Provide portable light at entrance to engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 April 2007
Resolved
Prove proper operation (visual and audible) of all bilge high level alarms IAW 46 CFR 119.530.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 April 2007
Resolved
Replace electrical junction box below steering console.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 24 May 2007
Construction/Loadline › Structures › Door
Issued 19 April 2007
Resolved
Adjust watertight door between galley and fresh water space.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 24 May 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 April 2007
Resolved
Prove proper operation of emergency light located at bottom of galley ladder.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 April 2007
Resolved
Remove dead end wiring below fresh water tank.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 24 May 2007
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 19 April 2007
Resolved
Make permanent repairs to hole in watertight bulkhead between galley and fresh water tank space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2011
Resolution: June 21, 2011 This activity was reopened to clear long standing, overdue deficiency(ies) **VESSEL WAS DELETED FROM SERVICE**//s// [name withheld], Sector New York, Civilian Marine Inspector, [email withheld] <mailto:[email withheld]>,
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 19 April 2007
Resolved
Prove proper servicing of all portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Fire Fighting › Fire Pumps › Gland Sealing
Issued 19 April 2007
Resolved
Repair leak in fire/bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Fire Fighting › Nozzles › Number
Issued 19 April 2007
Resolved
Provide nozzle in way of fire station #4.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Stability › Watertight Integrity › General
Issued 19 April 2007
Resolved
Provide captive chains in way of all hatches on bow.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 24 May 2007
Documentation › Markings/Placards › Lifejacket Placard
Issued 19 April 2007
Resolved
Provide donning placards for each type of adult lifejacket provided onboard vessel.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 24 May 2007
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 19 April 2007
Resolved
Mark five child lifejackets with vessels name.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 19 April 2007
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 19 April 2007
Resolved
Replace retroreflective material on 88 adult lifejackets.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 24 May 2007
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 19 April 2007
Resolved
Provide four additional lifejackets. Vessel is restricted to carriage of 218 total persons until complete.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 24 May 2007
Accommodation/Occupational Safety › Potable Water System › General
Issued 19 April 2007
Resolved
Properly secure fresh water tanks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2011
Resolution: June 21, 2011 This activity was reopened to clear long standing, overdue deficiency(ies) **VESSEL WAS DELETED FROM SERVICE**//s// [name withheld], Sector New York, Civilian Marine Inspector, [email withheld] <mailto:[email withheld]>,
Construction/Loadline › Structures › Ventilators
Issued 19 April 2007
Resolved
Make repairs to wasted vent duct on main deck in way of boiler space.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 24 May 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 19 April 2007
Resolved
Prove proper operation of lighting in fresh water tank space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2011
Resolution: June 21, 2011 This activity was reopened to clear long standing, overdue deficiency(ies) **VESSEL WAS DELETED FROM SERVICE**//s// [name withheld], Sector New York, Civilian Marine Inspector, [email withheld] <mailto:[email withheld]>,
Engineering › Bilge Water Management System › Not Operational
Issued 19 April 2007
Resolved
Prove proper operation of bilge pump in lazerette space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Engineering › Bilge Water Management System › Piping
Issued 19 April 2007
Resolved
Repair bilge piping in fresh water tank space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2007
Documentation › Markings/Placards › Warning Signs
Issued 19 April 2007
Resolved
Mark emergency escape hatch on main deck, bow with "Emergency Escape - Keep Clear".
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 24 May 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 19 April 2007
Resolved
Prove proper operation of automatic acuation of emergency lighting at ladder to restrooms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Fire Fighting › Means of Escape › Blocked
Issued 19 April 2007
Resolved
Prove proper operation of emergency escape hatch from fresh water tank space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2007
Stability › Watertight Integrity › General
Issued 19 April 2007
Resolved
Provide watertight hatch in way of lazerette.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 24 May 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 April 2007
Resolved
Conduct man-overboard and firefighting drills in the presence of a Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2007
Documentation › Markings/Placards › Warning Signs
Issued 19 April 2007
Resolved
Mark emergency escape in engine compartment.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 24 May 2007
Engineering › Steam Boiler (auxiliary/waste heat) › Fuel Oil Burner
Issued 1 December 2005
Resolved
Provide plans for new boiler installation
Action required: 705 - Other - as specified
Due 4 January 2006
Resolved 16 March 2006
Engineering › Steam Boiler (auxiliary/waste heat) › Fuel Oil Burner
Issued 1 December 2005
Resolved
Provide specifications on old and new boiler.
Action required: 705 - Other - as specified
Due 4 January 2006
Resolved 16 March 2006
Engineering › Fuel Oil Service System › Hose
Issued 1 December 2005
Resolved
Install correct type of flex hose on new generator fuel system. Hose to meet SAE J-1942 for the use on fuel systems.
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 19 April 2006
Engineering › Thrusters › Motor
Issued 1 December 2005
Resolved
Reconnect bow thruster in E/R.
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 19 April 2006
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 1 December 2005
Resolved
Install lagging on 99 KW generator.
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 19 April 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 1 December 2005
Resolved
Reinstall receptacle IVO 99 KW generator.
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 19 April 2006
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 1 December 2005
Resolved
Provide proper support brackets for 99 KW generator jacketwater intake and discharge flex hoses.
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 19 April 2006
Engineering › Fuel Oil Service System › Piping
Issued 1 December 2005
Resolved
Repair fuel leak on boiler piping IVO RAYCOR filter located in the E/R.
Action required: 705 - Other - as specified
Due 4 January 2006
Resolved 19 April 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 1 December 2005
Resolved
Reinstall overhead light IVO 99 KW generator.
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 19 April 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 1 December 2005
Resolved
Reinstall emergency light IVO E/R main distribution panel.
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 19 April 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 1 December 2005
Resolved
Replace cracked light globe on fixture in E/R.
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 19 April 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 1 December 2005
Resolved
Install missing globe to fixture in E/R.
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 19 April 2006
Construction/Loadline › Structures › Door
Issued 1 December 2005
Resolved
Repair exterior door IWO port side mid-ship.
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 19 April 2006
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 1 December 2005
Resolved
Provide double clamps for jacket water intake flex hose on 99 KW generator IVO JABSCO pump.
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 19 April 2006
Engineering › Bilge Water Management System › Piping
Issued 1 December 2005
Resolved
Prior to carrying passengers install fixed bilge piping in void #2 where soft patch is in line fwd of bulkhead.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 April 2006
Resolved 11 May 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 1 December 2005
Resolved
Remove and properly dispose of mixture in all bilges.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 11 May 2006
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 1 December 2005
Resolved
Repair exhaust leak on port engine.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 11 May 2006
Electrical › Electric Generation Source (service) › Conductor
Issued 1 December 2005
Resolved
Remove cut electrical wire and lighting box overhead in galley.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 11 May 2006
Stability › Weathertight Integrity › General
Issued 1 December 2005
Resolved
Replace cabin window stbd side forward.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 28 June 2007
Stability › Weathertight Integrity › General
Issued 1 December 2005
Resolved
Replace cracked glass on door main deck stbd side aft
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 11 May 2006
Electrical › Electric Generation Source (service) › Switch
Issued 1 December 2005
Resolved
Label all switches in electrical panel stbd side of liquor freezer.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 19 April 2006
Stability › Watertight Integrity › General
Issued 1 December 2005
Resolved
Make E/R bulkhead stbd side watertight IWO through-hull pipe
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 12 May 2006
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 1 December 2005
Resolved
Install new non-conductive matting below switchboard in E/R.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 11 May 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 1 December 2005
Resolved
Remove garden hose in aft part of water tank space coming from center overhead.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 11 May 2006
Engineering › Steering Gear System › Chain
Issued 1 December 2005
Resolved
Repair steering cable installation so that cable rides in channel.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 28 June 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 December 2005
Resolved
Install guard for moving machinery on fire pump.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 11 May 2006
Engineering › Fuel Oil Service System › Ventilation
Issued 1 December 2005
Resolved
Install 30 x 30 mesh screens on fuel vents.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 11 May 2006
Fire Fighting › Fire Pumps › Pumpshaft
Issued 1 December 2005
Resolved
Repair excessive water leak on fire pump.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 12 May 2006
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 1 December 2005
Resolved
Install lagging on fire pump exhaust.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 11 May 2006
Electrical › Electrical Distribution System (service) › Conductor
Issued 1 December 2005
Resolved
Properly install wire nuts or remove dead end wire on port engine.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 11 May 2006
Engineering › Bilge Water Management System › Piping
Issued 1 December 2005
Resolved
Prior to carrying passengers make proper repairs to portion of leaking (hole) bilge piping located IVO galley space.
Action required: 705 - Other - as specified
Due 19 April 2006
Resolved 11 May 2006
Engineering › Bilge Water Management System › Manifold
Issued 1 December 2005
Resolved
Make bilge suction IVO forward peak operable from remote location (main deck).
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 11 May 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 1 December 2005
Resolved
Provide serviceable B-II fire extinguisher.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 11 May 2006
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 1 December 2005
Resolved
Provide current edition of Coast Pilot and Light list.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 11 May 2006
Personnel › Training › Familiarization Training
Issued 1 December 2005
Resolved
Prior to carrying passengers conduct fire and man overboard drills to the satisfaction of attending Marine Inspector.
Due 19 April 2006
Resolved 28 June 2007
Personnel › Manning/Qualifications › Qualified Individual (VRP)
Issued 1 December 2005
Resolved
Update Senior Deckhand Letter.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 11 May 2006
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 1 December 2005
Resolved
Provide valid operator license and FCC radio permit.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 11 May 2006
Engineering › Bilge Water Management System › Valve
Issued 1 December 2005
Resolved
Provide labeling (open/closed) and directional (arrow) for both fwd remote bilge valves.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 11 May 2006
Engineering › Fuel Oil Service System › Piping
Issued 1 December 2005
Resolved
Make repairs to fuel line leak IVO E/R.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2006
Resolved 12 May 2006
Fire Fighting › Fire Pumps › Impeller
Issued 1 December 2005
Resolved
Provide serviceable belt for fire pump
Action required: 705 - Other - as specified
Due 19 May 2006
Resolved 12 May 2006
Engineering › Fuel Oil Service System › Hose
Issued 1 December 2005
Resolved
Install clamps on fitting ends of fire pump fuel lines as discussed.
Action required: 705 - Other - as specified
Due 19 May 2006
Resolved 12 May 2006
Engineering › Fuel Oil Service System › Tank
Issued 1 December 2005
Resolved
While underway to conduct drills with Coast Guard vessel lost propulsion in both MDE's. Coast Guard observed water in the fuel filters and vsl rep believes this to be the cause of the engine failure. Prior to carrying passengers provide casual analysis for engine failure, steps taken to make proper repairs and conduct underway tests to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 1 June 2006
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 1 December 2005
Resolved
Make proper repairs to coolant leak from the fwd inboard side of the port MDE.
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 28 June 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 1 December 2005
Resolved
Clean E/R bilge and properly dispose of all oily / gas filled absorbent material.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 28 June 2007
Fire Fighting › Fire Pumps › Impeller
Issued 1 December 2005
Resolved
Replace flex hose on fire pump on salt water intake.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 1 June 2006
Resolution: Replaced.
Engineering › Fuel Oil Service System › Filter
Issued 1 December 2005
Resolved
Repair leaks on fuel filter (port and stbd MDE)
Due 8 June 2006
Resolved 28 June 2007
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 1 December 2005
Resolved
Properly dispose of old battery and clean up oil underneath (stbd side fwd engine room)
Due 8 June 2006
Resolved 28 June 2007
Engineering › Fuel Oil Service System › Filter
Issued 1 December 2005
Resolved
Repair leaking oil filter on stbd MDE (upper).
Due 8 June 2006
Resolved 28 June 2007
Fire Fighting › Fire Hoses › Number
Issued 1 December 2005
Resolved
Replace (01) fire hose/hydrant at engine room entrances.
Due 8 June 2006
Resolved 28 June 2007
Electrical › Electric Generation Source (service) › Power Requirement
Issued 9 September 2005
Resolved
Prove proper operation of remote shutdown for temporary generator from the pilothouse.
Action required: 705 - Other - as specified
Due 10 September 2005
Resolved 10 September 2005
Electrical › Electric Generation Source (service) › Generator
Issued 9 September 2005
Resolved
Verify the generator is proper secured (strapping).
Action required: 705 - Other - as specified
Due 10 September 2005
Resolved 10 September 2005
Stability › Watertight Integrity › General
Issued 9 September 2005
Resolved
Make generator cable penetrations watertight.
Action required: 705 - Other - as specified
Due 10 September 2005
Resolved 10 September 2005
Electrical › Electric Generation Source (service) › Generator Cable
Issued 9 September 2005
Resolved
Proper secure temporary generator cables.
Action required: 705 - Other - as specified
Due 10 September 2005
Resolved 10 September 2005
Electrical › Electric Generation Source (service) › Generator
Issued 23 August 2005
Resolved
Make permanent repairs to ship service generator. Passenger count reduced to 150 (all restricted to the main deck) until permanent repairs completed to the satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Due 15 November 2005
Resolved 24 March 2006
Resolution: Plan review completed. Plan review for new generator installation is under Activity # 2544068.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 July 2005
Resolved
Conduct MOB drill & log in logbook prior to first commercial operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2005
Resolved 20 July 2005
Resolution: Conducted MOB.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 July 2005
Resolved
Provide valid Radio Operator Permit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2005
Resolved 1 December 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 1 July 2005
Resolved
Update call sigh in AIS, emergency broadcast placard, and ship documents.
Due 14 July 2005
Resolved 20 July 2005
Resolution: Updated as required.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 1 July 2005
Resolved
Update local notice to mariners for July prior to first commercial operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2005
Resolved 4 July 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 July 2005
Resolved
Remove/terminate cable IWO port nav light.
Due 14 July 2005
Resolved 20 July 2005
Resolution: Cable removed.
Lifesaving › Lifejacket/PFD (Type II) › Storage
Issued 1 July 2005
Resolved
Remove all Type II PFDs.
Due 14 July 2005
Resolved 1 July 2005
Resolution: All Type II PFDs removed.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 1 July 2005
Resolved
Remove 7 kapok, Type I PFDs or post donning instructions.
Due 14 July 2005
Resolved 1 July 2005
Resolution: Kapok PFDs removed.
Fire Fighting › Means of Escape › Blocked
Issued 1 July 2005
Resolved
Make emergency escape hatch in galley accessible.
Due 14 July 2005
Resolved 20 July 2005
Resolution: Hatch made accessible for exit.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 July 2005
Resolved
Remove plastic tie supports for piping overhead in galley storage, replace with metal supports.
Due 14 July 2005
Resolved 20 July 2005
Resolution: Corrected as required.
Stability › Water on Deck › General
Issued 1 July 2005
Resolved
Remove standing water from boiler room void.
Due 14 July 2005
Resolved 20 July 2005
Resolution: Water removed.
Personnel › Manning/Qualifications › First Aid Certified Personnel
Issued 1 July 2005
Resolved
Provide valid first aid/CPR card.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2005
Resolved 1 December 2005
Construction/Loadline › Structures › Manhole
Issued 1 July 2005
Resolved
Provide gaskets for both (2) fwd flush deck hatches.
Due 14 July 2005
Resolved 20 July 2005
Resolution: Gaskets installed.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 1 July 2005
Resolved
Make repairs and prove proper operation of collision bulkhead bilge isolation valve.
Due 14 July 2005
Resolved 20 July 2005
Resolution: Valve cleaned, adjusted, and operationally tested.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 1 July 2005
Resolved
Provide light bulb to galley emergency lighting.
Due 14 July 2005
Resolved 27 July 2005
Resolution: Bulb installed and tested.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 1 July 2005
Resolved
Label E/R emergency escape hatch.
Due 14 July 2005
Resolved 20 July 2005
Resolution: Labeled as required.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 July 2005
Resolved
Make proper repairs to E/R light fixture stbd side aft.
Due 14 July 2005
Resolved 20 July 2005
Resolution: Light fixture repaired.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 July 2005
Resolved
Mount junction box IVO E/R P/S aft.
Due 14 July 2005
Resolved 20 July 2005
Resolution: Junction box mounted.
Fire Fighting › Combustible Materials › Insulation
Issued 1 July 2005
Resolved
Install lagging to p/S MDE expansion joint.
Due 14 July 2005
Resolved 20 July 2005
Resolution: Lagging installed.
Stability › Watertight Integrity › General
Issued 1 July 2005
Resolved
Install watertight cover IVO tank rm aft bulkhead.
Due 14 July 2005
Resolved 20 July 2005
Resolution: Cover installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 July 2005
Resolved
Provide glass covers to aft stair tower light fixtures P/S side.
Due 14 July 2005
Resolved 20 July 2005
Resolution: Covers installed.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 1 July 2005
Resolved
Install machinery guard to bilge pump.
Due 14 July 2005
Resolved 20 July 2005
Resolution: Guard installed.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 1 July 2005
Resolved
Install 30 X 30 mesh screen to fuel vents.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2005
Resolution: Screens installed.
Fire Fighting › Fire Main › Condition
Issued 1 July 2005
Resolved
Prove proper operation of fire/bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2005
Resolution: Dewatered 3 different voids.
Engineering › Bilge Water Management System › Pump
Issued 1 July 2005
Resolved
Prove proper operation of electric bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2005
Resolution: Dewatered various voids.
Engineering › Sea-water System (primary cooling) › Pump
Issued 1 July 2005
Resolved
Make proper repairs to port MDE jacket water pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2005
Resolution: Repaired as required.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 July 2005
Resolved
Conduct fire and MOB drill to the satisfaction of attending marine inspector.
Due 14 July 2005
Resolved 20 July 2005
Resolution: Witnessed satisfactory MOB.
Engineering › Bilge Water Management System › Manifold
Issued 1 July 2005
Resolved
Provide operating instructions for bilge manifolds system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2005
Resolution: Instructions posted.
Fire Fighting › Fire Main › Condition
Issued 1 July 2005
Resolved
Provide operating instructions for fire/bilge manifold system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2005
Resolution: Instructions posted.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 1 July 2005
Resolved
Prove proper operation of emergency lighting.
Due 14 July 2005
Resolved 20 July 2005
Resolution: All emergency lights tested.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 July 2005
Resolved
Replace cracked window portside main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2005
Resolved 1 December 2005
Fire Fighting › Fire Main › Condition
Issued 7 December 2004
Resolved
Ensure complete operational test of fire system is conducted prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2005
Resolved 20 July 2005
Engineering › Bilge Water Management System › Piping
Issued 7 December 2004
Resolved
Conduct an operational test of all bilge suctions prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2005
Resolved 20 July 2005
Engineering › Lubricating Oil Service System › Hose
Issued 7 December 2004
Resolved
Reattach all shaft oil lines.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2005
Resolved 20 July 2005
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 18 March 2004
Resolved
Provide FCC Safety Certificate with current call sign. LEGACY COMPONENT DESC: FCC Safety Certificate
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 15 April 2004
Resolution: Observed valid FCC Satety Certificate.
Documentation › Certificates/Documents › FCC SSL
Issued 18 March 2004
Resolved
Provide copy of permanent Marine Radio Operator permit for vsl operator [name withheld] COMPONENT DESC: Radio Operators Permit
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 13 September 2004
Resolution: Provided FCC registration web receipt. Call FCC at [phone withheld] and confirmed that license has been updated and expires 20Mar09.
Documentation › Logs/Records › Drug Test Records
Issued 18 March 2004
Resolved
Provide copy of DAPI Employer Policy LEGACY COMPONENT DESC: DAPI Employer Policy
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 15 April 2004
Resolution: Employer Policy reviewed and supervisor training noted.
Documentation › Logs/Records › Drug Test Records
Issued 18 March 2004
Resolved
Conduct and Log annual supervisory training. LEGACY COMPONENT DESC: DAPI Supervisot Training
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 15 April 2004
Resolution: Employer Policy reviewed and supervisor training noted.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 18 March 2004
Resolved
Provide current edit of Navigation Rules of the Road publication. LEGACY COMPONENT DESC: Rules of teh Road M16672.2E
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 15 April 2004
Resolution: Nav Rules provided.
Stability › Weathertight Integrity › General
Issued 18 March 2004
Resolved
Repair cracked windows (6 total) on main deck cabin area. LEGACY COMPONENT DESC: Windows
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 13 September 2004
Resolution: Replaced all cracked windows.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 18 March 2004
Resolved
Make E/R aft bulkhead watertight. LEGACY COMPONENT DESC: E/R Aft Bulkhead
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 13 September 2004
Resolution: Installed 5200 to make bulkhead watertight.
Engineering › Compressed Air System (control) › Compressor
Issued 18 March 2004
Resolved
Make repairs to head gasket leak on aft air compressor LEGACY COMPONENT DESC: Head Gasket
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 15 April 2004
Resolution: Operationally tested air compressor, all sat.
Fire Fighting › Fire Pumps › Pressure
Issued 18 March 2004
Resolved
Prove proper operation of fire pump. Vsl restricted from carrying passengers until cleared.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 15 April 2004
Resolution: Witnessed satisfactory operation of fire pump with over 50 PSI, solid stream of water, and no leaks in fire main piping.
Engineering › Fuel Oil Service System › Filter
Issued 18 March 2004
Resolved
Make repairs to Raycor fuel leaks located underneath inpengment bowls. LEGACY COMPONENT DESC: Raycor Filters
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 15 April 2004
Resolution: Bowls clean and dry.
Engineering › Sea-water System (primary cooling) › Valve
Issued 18 March 2004
Resolved
Make repairs to port MDE Sea Valve water leak. LEGACY COMPONENT DESC: Sea Valves
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 15 April 2004
Resolution: Operationally tested MDE sea valve, no leak; all sat.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 18 March 2004
Resolved
Make repairs to port MDE exhaust leak. LEGACY COMPONENT DESC: Exhaust
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 13 September 2004
Resolution: Conducted satisfactory operational test, all sat, negative exhaust leak.
Engineering › Generator (propulsion-electric) › Cable
Issued 18 March 2004
Resolved
Install lagging on aft (99kw) generator near ladderwell. LEGACY COMPONENT DESC: Lagging
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 17 September 2004
Resolution: Lagging installed.
Accommodation/Occupational Safety › Potable Water System › General
Issued 18 March 2004
Resolved
Make repairs to leak on potable water tank piping in Galley storage room. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 15 April 2004
Resolution: Operationally tested, all sat.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 18 March 2004
Resolved
Provide K-POC donning placard. LEGACY COMPONENT DESC: Donning Placard
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 13 September 2004
Resolution: Kapoc PFDs removed and replaced with foam PFDs.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 March 2004
Resolved
Provide 60 ft bouyant lifeline for ring buoy.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 15 April 2004
Resolution: Line installed.
Lifesaving › Visual Distress Signals (General) › Condition
Issued 18 March 2004
Resolved
Provide waterlight for life ring buoy. LEGACY COMPONENT DESC: Waterlight
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 15 April 2004
Resolution: Waterlight installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 March 2004
Resolved
Provide 3-6 ft Bouyant line for lifering bouy waterlight
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 15 April 2004
Resolution: Line installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 March 2004
Resolved
Provide Coast Guard approved or equivalent first aid kit. LEGACY COMPONENT DESC: First Aid Kit
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 15 April 2004
Resolution: CG first aid kit provided.
Fire Fighting › Ventilation Systems › Ducts
Issued 18 March 2004
Resolved
Install flame screen (30X30) mesh on fuel system vent piping. LEGACY COMPONENT DESC: Flame screen
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 13 September 2004
Resolution: Flame screen installed.
Fire Fighting › Fire Main › Condition
Issued 18 March 2004
Resolved
Prove proper operation of fire main system.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 15 April 2004
Resolution: Witnessed satisfactory operation of fire pump with over 50 PSI, solid stream of water, and no leaks in fire main piping.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 18 March 2004
Resolved
Make repairs to Boiler room bilge high level alarm. LEGACY COMPONENT DESC: High level alarms
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 15 April 2004
Resolution: Wiring repaired on boiler room bilge high level alarm and operationally tested, all sat.
Construction/Loadline › Structures › End Bulkhead
Issued 18 March 2004
Resolved
Re-Install access plate to Tank Room Aft bulkhead. LEGACY COMPONENT DESC: Bulkhead
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 15 April 2004
Resolution: Access plate installed.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 18 March 2004
Resolved
Provide information on recently purchased wooden chairs (96) in conjunction with open CG-835 on fire load plan. LEGACY COMPONENT DESC: Fire Load PLan
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 8 December 2004
Resolution: Received faxed copy of 1954 stability test which accounted for 360 wood chairs. Vessel currently has less than 100 wood chairs.
Navigation › Collision/Grounding Avoidance
Issued 2 April 2003
Resolved
Sand Matte behind Nav Lights or paint flat black. LEGACY COMPONENT DESC: Navigation Lights
Due 17 April 2003
Resolved 17 April 2003
Resolution: Area sanded
Navigation › Collision/Grounding Avoidance
Issued 2 April 2003
Resolved
Make Nav Lights weathertight. LEGACY COMPONENT DESC: Navigation Lights
Due 17 April 2003
Resolved 17 April 2003
Resolution: Inside lights were cleaned and cap was cleaned to make it weather tight.
Electrical › Electric Supply System (service)
Issued 2 April 2003
Resolved
Address exposed wire to search light in pilot house. LEGACY COMPONENT DESC: Cable
Due 17 April 2003
Resolved 17 April 2003
Resolution: Wire was replaced and made permanent and given a seperate circuit.
Engineering › Bilge Water Management System
Issued 2 April 2003
Resolved
Label bilge pump location indicator in wheel house. LEGACY COMPONENT DESC: Interface Detector
Due 17 April 2003
Resolved 17 April 2003
Resolution: All indicator''''s were properly labeled.
Communications › Internal Communications System
Issued 2 April 2003
Resolved
Ensure public address system is working throughout the vessel.
Due 17 April 2003
Resolved 17 April 2003
Resolution: System properly working
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 2 April 2003
Resolved
Secure furniture to bulkhead, second deck admidships.
Due 17 April 2003
Resolved 17 April 2003
Resolution: Cabinet was secured to bulkhead.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 April 2003
Resolved
Address broken e-lighting IWO staicase second deck level.
Due 17 April 2003
Resolved 17 April 2003
Resolution: E-lighting replaced.
Electrical › Electric Supply System (service) › Cable
Issued 2 April 2003
Resolved
Remove old DC cable IWO switchboard in engine room.
Due 17 April 2003
Resolved 17 April 2003
Resolution: Cables removed.
Fire Fighting › Combustible Materials
Issued 2 April 2003
Resolved
Rmove plastic barrel in engine room and replace with metal barrel with lid
Due 17 April 2003
Resolved 17 April 2003
Resolution: Metal barrel put in service
Fire Fighting › Combustible Materials
Issued 2 April 2003
Resolved
Remove items stored behind switchboard in engine room.
Due 17 April 2003
Resolved 17 April 2003
Resolution: Area cleared out behind switchboard.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 2 April 2003
Resolved
Install a non-conductive handrail on main distribution panel.
Due 24 April 2003
Resolved 2 April 2003
Fire Fighting › Remote Fuel Shutoff
Issued 2 April 2003
Resolved
Install a flame impingment guard around emergency fuel shut offs.
Due 17 April 2003
Resolved 17 April 2003
Resolution: Guards installed.
Fire Fighting › Combustible Materials
Issued 2 April 2003
Resolved
Remove alcohol and flamable items IWO of boiler.
Due 17 April 2003
Resolved 17 April 2003
Resolution: Items removed from boiler area.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 2 April 2003
Resolved
Address life jackets with retro tape as needed.
Due 17 April 2003
Resolved 17 April 2003
Resolution: Retro tape added.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 2 April 2003
Resolved
Seperate child life jackets from adult PFD.
Due 17 April 2003
Resolved 17 April 2003
Resolution: PFD''s labeled and stored seperately.
Navigation › Piloting/Steering › Marine Charts
Issued 2 April 2003
Resolved
Obtain up to date chart of operating area.
Due 17 April 2003
Resolved 17 April 2003
Resolution: Charts updated.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 2 April 2003
Resolved
Show proper documentation of drug and alcohol program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2003
Resolution: Contact available.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 2 April 2003
Resolved
Submit fire load plan to MSC for approval IAW NVIC 9-97 LEGACY COMPONENT DESC: Furniture/Furnishings
Due 2 June 2003
Resolved 8 December 2004
Resolution: Received faxed copy of 1954 stability test which accounted for 360 wood chairs. Vessel currently has 87 wood chairs.
Accommodation/Occupational Safety › Occupational Safety
Issued 2 April 2003
Resolved
Insert deck plating behind distribution panel to prevent personal injury
Due 17 April 2003
Resolved 17 April 2003
Resolution: Plating inserted.
Construction/Loadline › Structures › Superstructure
Issued 2 April 2003
Resolved
Replace broken window port side.
Due 23 April 2003
Resolved 23 April 2003
Resolution: Window replaced.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 2 April 2003
Resolved
Designate in writing senior deck hand per NVIC 1-91
Due 23 April 2003
Resolved 23 April 2003
Resolution: Issue addressed.
Engineering › Sea-water System (primary cooling) › Hose
Issued 2 April 2003
Resolved
Address leak on port MDE raw water hose
Due 23 April 2003
Resolved 23 April 2003
Resolution: Hose replaced.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 2 April 2003
Resolved
Address leak to fire pump and show proper operation to attending M.I.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2003
Resolution: Packing gland replaced leak addressed fire pump tested.
Accommodation/Occupational Safety › Occupational Safety
Issued 2 April 2003
Resolved
Place chain guard on lazarette void.
Due 23 April 2003
Resolved 23 April 2003
Resolution: Chain guard added.
Accommodation/Occupational Safety › Occupational Safety
Issued 2 April 2003
Resolved
Complete building of embarkation ladder
Due 23 April 2003
Resolved 23 April 2003
Resolution: Ladder completed
Fire Fighting › Fire Pumps
Issued 2 April 2003
Resolved
Install operable gauge on fire pump. LEGACY COMPONENT DESC: Pressure
Due 22 May 2003
Resolved 22 May 2003
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 April 2003
Resolved
Conduct drills to the satisfaction of attending M.I.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2003
Resolution: Satisfactory MOB and Fire drill conducted.
Engineering › Diesel Engine (auxiliary)
Issued 28 March 2002
Resolved
Replace generator oil temperature and pressure gauges. LEGACY COMPONENT DESC: Gauges
Condition: Improper/Lack of Maintenance
Due 10 April 2002
Resolved 12 April 2002
Resolution: Generator oil temperature and pressure gauges cleaned and readable ([name withheld]).
Accommodation/Occupational Safety › Occupational Safety
Issued 28 March 2002
Resolved
Post hearing conservation placard at entrance to engine room. LEGACY COMPONENT DESC: Hearing conservation
Condition: Unknown
Due 10 April 2002
Resolved 12 April 2002
Resolution: Observed hearing conservation placard at entrance to engine room ([name withheld]).
Engineering › Thrusters
Issued 28 March 2002
Resolved
Install shaft guards on sewage discharge pump and generator/thruster. LEGACY COMPONENT DESC: Shaft
Condition: Unknown
Due 10 April 2002
Resolved 12 April 2002
Resolution: Observed new guards on sewage discharge pump and thruster generator ([name withheld]).
Lifesaving › Embarkation Appliances/Stations
Issued 28 March 2002
Resolved
Post emergency instructions for crew & passengers. LEGACY COMPONENT DESC: Designated Location
Condition: Unknown
Due 12 April 2002
Resolved 12 April 2002
Resolution: Emergency instructions aboard vessel and will be posted on main deck and in wheelhouse ([name withheld]).
Navigation
Issued 28 March 2002
Resolved
Provide updated Coast Pilot, distress flares and first aid kit medications. LEGACY COMPONENT DESC: Coast Pilot
Condition: Improper/Lack of Maintenance
Due 10 April 2002
Resolved 28 March 2002
Resolution: All expired articles replaced with new.
Lifesaving
Issued 28 March 2002
Resolved
Provide USCG with record of quarterly crew training and drills. LEGACY COMPONENT DESC: Logs/Training
Condition: Unknown
Due 28 June 2002
Resolved 17 April 2003
Resolution: 835 written 2 APR 03 to conduct drills
Electrical
Issued 26 April 2001
Resolved
Remove extention cords and properly hard wire recepticles where needed. (Galley fan, Heater and Refer thermostat)
Condition: Unknown
Due 15 May 2001
Resolved 19 July 2001
Accommodation/Occupational Safety
Issued 26 April 2001
Resolved
Propose measures to repair potable water tank or provide alternative.
Condition: Unknown
Due 15 May 2001
Resolved 19 July 2001
Engineering
Issued 26 April 2001
Resolved
Remove oil from E/R bildges. Maintain cleanliness. Propose preventive measures to do so via fax.
Condition: Unknown
Due 15 May 2001
Resolved 19 July 2001
Lifesaving
Issued 26 April 2000
Resolved
Mount lifejacket donning placards port and stbd of bar, and outside lifejacket lockers forward, as discussed.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Lifesaving
Issued 26 April 2000
Resolved
Repair lifejacket locker latches on fwd lockers.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Lifesaving
Issued 26 April 2000
Resolved
Provide retro tape (type II) on aft ring buoy.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Engineering
Issued 26 April 2000
Resolved
Install machinery belt guards on stbd generator and air compressor.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Construction/Loadline
Issued 26 April 2000
Resolved
Install/replace missing bell suction w/screen or strainer on bilge suction line in comp #9.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Construction/Loadline
Issued 26 April 2000
Resolved
Make repairs to comply with bilge suction requirements in comp #1 iaw 46CFR119.510: Either pipe bilge suction to bottom of compartment with proper bell mouth and strainer, OR seal watertight bulkhead and provide appropriate hand pump.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Electrical
Issued 26 April 2000
Resolved
Install clip/closure device for distribution panel in galley.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Electrical
Issued 26 April 2000
Resolved
Provide portable lighting (flashlight) in wheelhouse.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Lifesaving
Issued 26 April 2000
Resolved
Repair/replace fwd port ring buoy, including retro tape.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Documentation
Issued 26 April 2000
Resolved
Provide and post in wheelhouse Emergency Instruction List iaw 46CFR122.510.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Documentation
Issued 16 April 1999
Resolved
PROVIDE A COPY OF 46 CFR PARTS 114 THRU 124
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Documentation
Issued 16 April 1999
Resolved
PROVIDE A SENIOR DECK HAND LETTER
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Navigation
Issued 16 April 1999
Resolved
PROVIDE A DAY SHAPE (BALL) FOR ANCHORING
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Lifesaving
Issued 16 April 1999
Resolved
SEPERATE CHILD LIFE JACKETS FROM ADULTS IN FWD STORAGE BIN OF MAIN DECK.
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Electrical
Issued 16 April 1999
Resolved
FWD GALLEY COMPARTMENT: REPLACE BROKEN OUTLET ABOVE SMALL WHITE FREEZER
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Electrical
Issued 16 April 1999
Resolved
ENGINE ROOM: JUNCTION BOX LOCATED ON OVERHEAD STBD SIDE ABOVE AIR COMPRESSOR NEEDS A BLANK INSTALLED ON THE AFT SIDE OF BOX. NEED TO REMOVE DEAD ENDED WIRE RUNNING THROUGH 1/2" CONDUIT FWD TO BEHIND POWER PANEL BOARD
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Electrical
Issued 16 April 1999
Resolved
ENGINE ROOM: REMOVE (2) DEAD ENDED WIRES LOCATED ON THE PORT SIDE OF CENTER LINE BEHIND POWER PANNEL BOARD
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Electrical
Issued 16 April 1999
Resolved
ENGINE ROOM: INSTALL A BLANK ON TOP OF YELLOW GENERATOR (UNDER LADDER) WERE CABLE WAS REMOVED FROM BREAKER CONTROL BOX
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Electrical
Issued 16 April 1999
Resolved
INSTALL ELECTICAL GRADE MATTING IN FRONT OF MAIN POWER PANNEL BOARD
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Electrical
Issued 16 April 1999
Resolved
ENGINE ROOM: INSTALL GLOBES AND LIGHTS IN ENGINE ROOM LIGHTS OR REMOVE LIGHT FIXTURES AND WIRES, (2) TOTAL
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Construction/Loadline
Issued 16 April 1999
Resolved
AFT VOID (FWD OF LAZ): REPLACE MISSING BILGE LINE STRAINER
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Construction/Loadline
Issued 16 April 1999
Resolved
WATER TANK VOID: INSTALL A CAP ON THE 2" PIPE LOCATED ON THE FWD BULKHEAD,PORT SIDE. PIPE IS NOT CONNECTED TO ANYTHING AND HAS AN OLD UNION FITTING ON IT, OPEN TO THE SPACE.
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Accommodation/Occupational Safety
Issued 16 April 1999
Resolved
FWD GALLEY COMPARTMENT: SECURE HOT WATER HEATER WITH A BAND/BRACKET
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Construction/Loadline
Issued 25 November 1998
Resolved
Mechanically clean to bare metal rivets port/stbd side as marked for further evaluation by CG MI.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Construction/Loadline
Issued 25 November 1998
Resolved
Renew / repair flush deck scuttle stbd side galley stores and prove proper operation.
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Construction/Loadline
Issued 25 November 1998
Resolved
Conduct detailed gauging of lazarette to determine good metal. Gaugings areto be conducted in the presence of a CG MI and provide a report.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Construction/Loadline
Issued 25 November 1998
Resolved
C/R lazarette hull plating to good metal where wastage is below .281" or provide written calculations by a naval architect attesting to reduced scantlings IAW referenced alternative standards. Proposal subject to OCMI approval.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Construction/Loadline
Issued 25 November 1998
Resolved
As per calc's using ABS Steel Hull Vsls on Rivers & Intercoastal Service 3/7.15.1, C/R lazarette hull plating as marked. Provide weld quals & procedures. CG MI to witness fit up, root pass and final pass at a minimum.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Accommodation/Occupational Safety
Issued 25 November 1998
Resolved
ROPE OFF AREA FOR SAFETY ZONE AROUND BROKEN WINDOWS PORT AND STARBOARD SIDEUNTIL REPAIRS ARE AFFECTED.
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Navigation
Issued 25 November 1998
Resolved
Double nut steering turnbuckles, have all bolts facing down, put thimbles on cable connections, remove cable at quadrant for inspection and renew/align outboard sheaves in lazarette.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 25 November 1998
Resolved
Open and blue fit all sea valves. To be witnessed by CG MI.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 25 November 1998
Resolved
Submit repair proposal for wasted rivets above rudder as marked.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Electrical
Issued 25 November 1998
Resolved
Install covers stbd bilge system wiring conduit.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 25 November 1998
Resolved
Remove caulking behind lazarette transverse frames #3 and 4 for inspection by CG MI.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 25 November 1998
Resolved
Clean to good metal, lazarette bays 1-2 from CVK outboard past #3 rivet backing strap, port and stbd sides. CG MI to inspect area prior to any other work or recoating.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 25 November 1998
Resolved
Remove PVC piping from bilge system in bow thruster space and renew with ferrous piping.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 25 November 1998
Resolved
Make bow thruster supply and return hydraulic lines watertight at bulkhead penetration.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Electrical
Issued 25 November 1998
Resolved
Hardwire furnace and remove extension cord.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Lifesaving
Issued 25 November 1998
Resolved
Remove plywood from overhead or insulate with an approved non-combustible material above furnace. Insulate flue pipe.
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Navigation
Issued 25 November 1998
Resolved
Provide plan for rudder modifications subject to OCMI approval.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Engineering
Issued 25 November 1998
Resolved
Double clamp E/R generator overboard hose stbd side and before muffler. Remove kink in hose.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 25 November 1998
Resolved
Renew generator sea chest valve stbd side.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Engineering
Issued 25 November 1998
Resolved
Install radiator cap on AC generator.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 25 November 1998
Resolved
Weld 2 drilled holes as marked in aft bulkhead of water tank space.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Accommodation/Occupational Safety
Issued 25 November 1998
Resolved
Renew salon stbd exit door broken glass w/ safety glass.
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Engineering
Issued 25 November 1998
Resolved
Repair leaking furnace outlet piping "T".
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Accommodation/Occupational Safety
Issued 25 November 1998
Resolved
Renew or repair stbd water tank top where seam is cracked.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 25 November 1998
Resolved
Provide current gauging report, proof of original hull plate thickness and past gauging report from 1990.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 25 November 1998
Resolved
The 2 bilge suction valve reach rods in the bow thruster space must be readily accessible from the main deck.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Construction/Loadline
Issued 25 November 1998
Resolved
Gauge the wind/water strakes IWO 7 & 8 ft draft, both sides entire vsl length. Min 2 shots per plate as indicated.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 25 November 1998
Resolved
Gauge hull plating IWO props and bow thruster as indicated.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Electrical
Issued 6 August 1998
Resolved
ISOLATE ALL ELECTRICAL CIRCUITS IWO DAMAGE. DO NOT REENERGIZE CIRCUITS UNTIL TESTED BY A COMPETENT PERSON.
Condition: Unknown
Due 20 August 1998
Resolved 24 August 1998
Unknown
Issued 6 August 1998
Resolved
VESSEL IS NOT TO OPERATE WITH PASSENGERS ON BOARD UNTIL ALL REPAIRS TO THE VESSEL HAVE BEEN MADE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 20 August 1998
Resolved 24 August 1998
Construction/Loadline
Issued 6 August 1998
Resolved
SUBMIT REPAIR PROPOSAL FOR ALL DAMAGE SUSTAINED TO [name withheld].
Condition: Unknown
Due 20 August 1998
Resolved 24 August 1998
Fire Fighting
Issued 12 May 1998
Resolved
PROVIDE DOCUMENTATION FOR SERVICING OF PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 19 May 1998
Resolved 21 May 1998
Lifesaving
Issued 12 May 1998
Resolved
CONDUCT AND LOG A MAN OVERBOARD DRILL TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 19 May 1998
Resolved 21 May 1998
Documentation
Issued 12 May 1998
Resolved
PROVIDE PROOF OF FCC OPERATOR'S LICENSE AND SAFETY CERTIFICATE
Condition: Unknown
Due 19 May 1998
Resolved 21 May 1998
Unknown
Issued 29 April 1996
Resolved
MAKE PERMANENT REPAIR TO DRIPPING HEATING PIPE IN FALLEY IWO ENGINE ROOM BULKHEAD.
Condition: Unknown
Due 1 June 1996
Resolved 3 June 1996
Lifesaving
Issued 29 April 1996
Resolved
PROVIDE EVIDENCE OF SUPERVISOR AND EMPLOYEE TRAINING. VESSEL EMPLOYER IS NOT TO OPERATE AFTER 29MAY96.
Condition: Unknown
Due 29 May 1996
Resolved 3 June 1996
Engineering
Issued 29 April 1996
Resolved
PROVIDE FLAME IMPINGEMENT PROTECTION FOR RACOR FUEL FILTER ON AUX AC GENERATOR.
Condition: Unknown
Due 12 May 1996
Resolved 3 June 1996
Fire Fighting
Issued 4 May 1994
Resolved
PROVIDE [name withheld] A COPY DELIVERY RECEIPT OF 2-15 LBS CO2 UL APPROVED FOR MARINE USE FIRE EXTINQUISHER. THIS REQUIREMENT CAN BE CLEARED VIA FAX. [phone withheld].
Condition: Unknown
Due 24 May 1994
Resolved 24 May 1994
Documentation
Issued 29 June 1993
Resolved
PROVIDE PROOF OF ENROLLMENT IN CHEMICAL TESTING PROGRAM PURSUANT TO 46 CFR 16.260. THIS REQUIREMENT NEEDS TO BE COMPLETED NOT LATER THAN 17MAY93.
Condition: Unknown
Due 12 August 1993
Resolved 12 August 1993
Construction/Loadline
Issued 13 November 1992
Resolved
CROP AND RENEW THE FOLLOWING IN THE FORWARD VOID:_x001C_ PORT SIDE LONGITUDINAL BETWEEN FRAME 2 AND 5._x001C_ #2 HULL FRAME IN WAY OF DECK BEAM AND FLOOR._x001C_ #3 HULL FRAME IN WAY OF DECK BEAM.
Condition: Unknown
Due 13 November 1992
Resolved 13 November 1992
Construction/Loadline
Issued 13 November 1992
Resolved
REPAIR LEAK IN MAIN DECK HATCH TO FORWARD VOID AND HATCH RIM AND DECK UNION.
Condition: Unknown
Due 13 November 1992
Resolved 13 November 1992
Documentation
Issued 18 June 1992
Resolved
PROVIDE APPROVED STABILITY CALCULATIONS TO INCLUDE CANOPY ON UPPER DECK, TOLOCAL [name withheld] ARCHITECT INFORMATION, CANOPY MAY BE INSTALLED UNTIL COMPLETION OF THIS REQUIREMENT.
Condition: Unknown
Due 18 June 1992
Resolved 18 June 1992
Construction/Loadline
Issued 22 November 1990
Resolved
PROVIDE CONSTRUCTION DETAILS IN RESPECT TO RIVETING; THE TYPE OF RIVETS, MATERIAL AND SIZE USED FOR ORIGINAL CONSTRUCTION AND SUBSEQUENT ALTERATIONS
Condition: Unknown
Due 22 November 1990
Resolved 22 November 1990
Construction/Loadline
Issued 22 November 1990
Resolved
PROVIDE REPORT OF HULL THICKNESS GAUGING CONDUCTED 22NOV90 ACCOMPANIED WITHSCANTLINGS OF ORIGINAL CONSTRUCTION.
Condition: Unknown
Due 22 November 1990
Resolved 22 November 1990
Electrical
Issued 14 September 1990
Resolved
PROVIDE ELECTRICAL/WIRING PLANS FOR RECENT RENOVATION AND PROPOSED WORK.
Condition: Unknown
Due 14 September 1990
Resolved 14 September 1990
Accommodation/Occupational Safety
Issued 14 September 1990
Resolved
MAKE OPERABLE FROM BOTH INSIDE AND OUTSIDE EMERGENCY ESCAPE HATCHES IN GALLEY; ALSO LABEL THEM.
Condition: Unknown
Due 14 September 1990
Resolved 14 September 1990
Electrical
Issued 14 September 1990
Resolved
REPLACE GLOBES, ADD COVERS FOR ENGINE ROOM LIGHTS.
Condition: Unknown
Due 14 September 1990
Resolved 14 September 1990
Electrical
Issued 14 September 1990
Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING.
Condition: Unknown
Due 14 September 1990
Resolved 14 September 1990
Engineering
Issued 14 September 1990
Resolved
PROPERLY LABEL BILGE VALVES IN ENGINE ROOM.
Condition: Unknown
Due 14 September 1990
Resolved 14 September 1990
Lifesaving
Issued 14 September 1990
Resolved
PROVIDE PROPER SET (2) OF PADDLES FOR RESCUE BOAT.
Condition: Unknown
Due 14 September 1990
Resolved 14 September 1990
Fire Fighting
Issued 14 September 1990
Resolved
PROVIDE PROPER OPERATION OF MAIN FIRE PUMP.
Condition: Unknown
Due 14 September 1990
Resolved 14 September 1990
Fire Fighting
Issued 14 September 1990
Resolved
PROPERLY MOUNT ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 14 September 1990
Resolved 14 September 1990
Fire Fighting
Issued 14 September 1990
Resolved
SERVICE PORTABLE FIRE EXTINGUISHERS AND PROVIDE COPY OF SERVICING REPORT.
Condition: Unknown
Due 14 September 1990
Resolved 14 September 1990
Navigation
Issued 14 September 1990
Resolved
REPLACE THE FOLLOWING NAVIGATION LIGHTS WITH THOSE OF AN APPROVED TYPE FORWARD MASTHEAD, PORT AND STARBOARD SIDELIGHTS, AND ALL-AROUND ANCHOR LIGHT. RELOCATE AS NECESSARY.
Condition: Unknown
Due 14 September 1990
Resolved 14 September 1990
Accommodation/Occupational Safety
Issued 14 September 1990
Resolved
PROPERLY LABEL ENGINE ROOM ESCAPES.
Condition: Unknown
Due 14 September 1990
Resolved 14 September 1990
Accommodation/Occupational Safety
Issued 14 September 1990
Resolved
PROVIDE HANDRAIL FOR ENGINEROOM STAIRCASE.
Condition: Unknown
Due 14 September 1990
Resolved 14 September 1990
Electrical
Issued 14 September 1990
Resolved
PROVIDE COVER FOR BATTERY BOX IN PILOT HOUSE.
Condition: Unknown
Due 14 September 1990
Resolved 14 September 1990
Documentation
Issued 14 September 1990
Resolved
PROVIDE PROOF OF MASTER'S LICENSE.
Condition: Unknown
Due 14 September 1990
Resolved 14 September 1990
Accommodation/Occupational Safety
Issued 14 September 1990
Resolved
PROVIDE DOCUMENTATION ON THE COMPOSITION AND FLAME SPREAD RATING ON THE MAIN AND UPPER DECK CARPETING AND ANY BACKING MATERIAL USED, INCLUDING ANY ADHESIVES.
Condition: Unknown
Due 14 September 1990
Resolved 14 September 1990
Navigation
Issued 21 February 1990
Resolved
PROVIDE BLACK BALL DAY SHAPE.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Navigation
Issued 21 February 1990
Resolved
INSTALL ALARM SYSTEM IN PILOT HOUSE FOR MAIN ENGINES.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Electrical
Issued 21 February 1990
Resolved
REMOVE PORTABLE ELECTRICAL WIRE.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Navigation
Issued 21 February 1990
Resolved
INSTALL ANCHOR LIGHT.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Engineering
Issued 27 April 1989
Resolved
INSTALL PROTECTIVE COVER TO THE ROTATING COUPLING OF THE ELECTRIC BILGE PUMP.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Fire Fighting
Issued 27 April 1989
Resolved
SERVICE EIGHT(8) HAND PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Engineering
Issued 27 April 1989
Resolved
REPAIR INOPERABLE ELECTRIC BILGE PUMP.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Accommodation/Occupational Safety
Issued 27 April 1989
Resolved
REPAIR LOOSE DRAIN LINE HOSE TO MSD HOLDING TANK.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Engineering
Issued 27 April 1989
Resolved
HYDROTEST AIR RECEIVERS TO 1-1/4 TIMES THE MAXIMUM ALLOWABLE WORKING PRESSURE.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Unknown
Issued 27 April 1989
Resolved
REPLACE ELECTRIC HOT WATER HEATER CONTROL COVER.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Construction/Loadline
Issued 2 May 1988
Resolved
REPLACE BROKEN GLASS IN DOOR ON UPPER DECK.
Condition: Unknown
Due 2 May 1988
Resolved 2 May 1988
Lifesaving
Issued 2 May 1988
Resolved
PROVIDE NEW HAND HELD FLARES AND SMOKE.
Condition: Unknown
Due 2 May 1988
Resolved 2 May 1988
Lifesaving
Issued 2 May 1988
Resolved
REPLACE GRAB LINES ON TWO LIFE RINGS.
Condition: Unknown
Due 2 May 1988
Resolved 2 May 1988
Lifesaving
Issued 2 May 1988
Resolved
PROVIDE ONE ADULT LIFE PRESERVER.
Condition: Unknown
Due 2 May 1988
Resolved 2 May 1988
Engineering
Issued 2 May 1988
Resolved
INSTALL A RELIEF VALVE ON STARBOARD AIR RECIEVER.
Condition: Unknown
Due 2 May 1988
Resolved 2 May 1988
Fire Fighting
Issued 2 May 1988
Resolved
REPLACE FORWARD FIRE HOSE ON UPPER DECK.
Condition: Unknown
Due 2 May 1988
Resolved 2 May 1988
Lifesaving
Issued 2 May 1988
Resolved
LABEL LIFE JACKET STOWAGE ON UPPER DECK.
Condition: Unknown
Due 2 May 1988
Resolved 2 May 1988
Lifesaving
Issued 2 May 1988
Resolved
REPLACE REFLECTIVE TAPE ON THREE ADULT LIFE PRESERVERS.
Condition: Unknown
Due 2 May 1988
Resolved 2 May 1988
Unknown
Issued 8 January 1987
Resolved
PROVIDE LOW LUBE OIL AND HIGH TEMPERATURE ALARMS FOR MAIN ENGINES.
Condition: Unknown
Due 8 January 1987
Resolved 8 January 1987
Unknown
Issued 8 January 1987
Resolved
PROVIDE PROPER LINING FOR BATTERY BOX IN ENGINE ROOM.
Condition: Unknown
Due 8 January 1987
Resolved 8 January 1987
Fire Fighting
Issued 6 March 1985
Resolved
REPAIR GAUGE TO VESSEL'S FIRE PUMP.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Fire Fighting
Issued 6 March 1985
Resolved
HAVE SEMI-PORTABLE SYSTEM IN THE ENGINE ROOM SERVICED.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985