MAURY USCG vessel records Sign in
← All vessels

SEA ANGLER

SEA ANGLER is a 1933 passenger vessel (inspected). The Coast Guard has recorded 63 inspections since 1985, most recently in August 2014, along with 101 deficiencies and 2 casualty investigations between 2011 and 2015.

Records from 1985 to 2015. Most recent: casualty investigation, 5 April 2015.

Built
1933
Last inspected
17 August 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY4837
Flag
UNITED STATES
366751430 (licence lapsed)
Maury page id
psix-41922

Inspections, by type

…with no type recorded9
Years with a record 28 calendar years (1985–2014)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it46 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCY4837MMSI 366751430 · expired · compulsorily equipped · granted 6 May 2008, cancelled 25 August 2018
WCW2981MMSI not assigned · expired · compulsorily equipped · granted 12 March 1996, cancelled 13 May 2006
WAJ7753MMSI not assigned · expired · compulsorily equipped · granted 12 January 1995, cancelled 28 May 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

S S LANE VICTORY In-service – Inspected · MISLE 62650 · 27 September 2008 · activity 3335487

Inspection history · 63

17 August 2014 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4965580
14 June 2012 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4351068
7 May 2012 Annual Inspection · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4258860
18 July 2011 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4086571
14 May 2009 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3475829
13 April 2009 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3450039
27 September 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3335487
6 May 2008 Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3175598
23 April 2008 Re-Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3167128
11 April 2007 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2903081
26 April 2006 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2598595
27 September 2005 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2493185
4 May 2005 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2337777
21 May 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2072273
30 September 2003 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1916338
2 September 2003 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1900418
31 July 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1861692
27 May 2003 Construction Oversight
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1774104
30 January 2003 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1737719
3 December 2002 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1713983
13 May 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1615407
18 December 2001 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1483914
2 May 2001 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1362515
15 May 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1406721
19 May 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1369176
27 April 1999 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1470774
11 March 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 803248
13 November 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1464804
14 May 1998 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1441379
2 October 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1402528
23 September 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1371988
16 September 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1115923
18 October 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1383375
19 July 1996 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1084549
27 June 1996 Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385765
26 March 1996 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1079683
31 May 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1387793
9 March 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1390019
9 January 1995 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1168589
18 October 1994 Examination of Repairs · Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 860678
1 June 1994 Re-Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1354787
18 January 1994 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1391930
24 May 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1407155
3 June 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1354173
5 May 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1470350
29 May 1991 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 905110
13 December 1990 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 910115
1 May 1990 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1238518
22 June 1989 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 887421
21 June 1989 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 889526
12 June 1989 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1207271
14 April 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1032272
6 July 1988 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1208108
16 June 1988 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 890904
27 November 1987 Deficiency Check · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1335757
12 August 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1336394
17 June 1987 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1313959
20 June 1986 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1306781
5 June 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 989221
17 September 1985 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1296165
9 August 1985 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1290765
30 May 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 981426
25 January 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 978108

Deficiency record · 101

Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 8 May 2012 Resolved
Repair/replace leaking fuel piping between the port and starboard main engines IAW 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 22 May 2012
Resolved 14 June 2012
Resolution: Fuel piping in the return line overhead the main engines was tightened and covered to prevent further fuel leaks.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 8 May 2012 Resolved
Repair/replace leaking fuel line at the generator connection point IAW 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 22 May 2012
Resolved 14 June 2012
Resolution: Fuel line at the generator was tightened and secured to prevent further fuel leaks.
Construction/Loadline › Hull › Longitudinal Frame
Issued 8 May 2012 Resolved
Remove all dry rot in the main engine space and treat IAW 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 8 June 2012
Resolved 14 June 2012
Resolution: Extensive areas of dry rot were cleaned & treated or replaced with new installations (battery box).
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 May 2012 Resolved
Place metal clips on wiring in machinery space between main engines in overhead IAW 46 CFR 183.340(a)(4).
Action required: 705 - Other - as specified
Due 8 June 2012
Resolved 14 June 2012
Resolution: Overhead wiring between the main engines has been secured with metal clips.
Construction/Loadline › Hull › Side Shell
Issued 7 May 2012 Resolved
Remove rot below starboard rub rail forward of the engine intake through hull and treat damaged wood.
Action required: 705 - Other - as specified
Due 8 May 2012
Resolved 8 May 2012
Resolution: Damaged plank was removed & replaced with a new plank.
Construction/Loadline › Hull › Side Shell
Issued 7 May 2012 Resolved
Treat damaged wood near the starboard bow in area of scraped planks.
Action required: 705 - Other - as specified
Due 8 May 2012
Resolved 8 May 2012
Resolution: Damaged wood was cleaned and treated with a sealing epoxy.
Engineering › Steering Gear System › Hydraulic Hose
Issued 13 April 2009 Resolved
Repair leaking hydraulic hose in starboard steering gear ram in accordance with 46 CFR 176.814.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2009
Resolved 14 May 2009
Resolution: All leaks corrected.
Engineering › Fuel Oil Service System › Filter
Issued 13 April 2009 Resolved
Remove fuel from fuel strainer bowls and demonstrate proper operation, or replace IAW 46 CFR 182.455(b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2009
Resolved 14 May 2009
Resolution: Spilled/leaked fuel removed. Engines run to demonstrate proper function of strainers.
Engineering › Bilge Water Management System › Piping
Issued 23 April 2008 Resolved
Make vessel bilge system comply with piping requirements of 46CFR182.710. A non-metallic pedro at bilge foot is acceptable.
Action required: 705 - Other - as specified
Due 5 May 2008
Resolved 13 April 2009
Resolution: Bilge piping replaced with installation meeting regulations. Conducted satisfactory operational test.
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 September 2005 Resolved
Scrape and treat port side of chain locker and starboard side.
Action required: 705 - Other - as specified
Due 11 October 2005
Resolved 6 October 2005
Resolution: Scraped and treated.
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 September 2005 Resolved
Scrape and treat forward starboard of storage room.
Action required: 705 - Other - as specified
Due 11 October 2005
Resolved 6 October 2005
Resolution: Scraped and treated.
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 September 2005 Resolved
Scrape and treat port and starboard side in middle of hold aft of lazarette.
Action required: 705 - Other - as specified
Due 11 October 2005
Resolved 6 October 2005
Resolution: Scraped and treated.
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 September 2005 Resolved
Scrape and treat angle hair on portside aprox 1 foot from hatch and middle below hatch in lazarette.
Action required: 705 - Other - as specified
Due 11 October 2005
Resolved 6 October 2005
Resolution: Scraped and treated.
Construction/Loadline › Structures › Scuttle
Issued 27 September 2005 Resolved
Replace/repair gasket on all hatches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2005
Resolved 6 October 2005
Resolution: Repaired gaskets.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 May 2005 Resolved
Remenants of old steel bulkheads (replaced by wood adjacent to steel) wasting away. Wasted steel falling into bildges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 18 May 2005
Resolution: Vessel removed wasted area of bulkhead.
Deck/Cargo › Cargo Refrigeration › General
Issued 4 May 2005 Resolved
refrigerators are loose.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 18 May 2005
Resolution: Refrigerator secured.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 4 May 2005 Resolved
Radio certificate expired.
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 5 May 2005
Resolution: Issued new certificate.
Electrical › Electrical Distribution System (service)
Issued 31 July 2003 Resolved
Replace the switch for the engine oil pump motor located between the main engines. The switch must be rated for switching service and also have a ground conductor properly connected. LEGACY COMPONENT DESC: Switch
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 2 September 2003
Resolution: Switch replaced.
Electrical › Electrical Distribution System (service)
Issued 31 July 2003 Resolved
Replace the portable electric cable installed from the shore tie plug to the generator switch box with a cable rated for permanent shipboard installation. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 2 September 2003
Resolution: Permanently installed with conduit pipe.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 31 July 2003 Resolved
Provide guards around the front pulleys on both main engines.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 2 September 2003
Resolution: Guards installed.
Engineering › Fuel Oil Service System
Issued 31 July 2003 Resolved
Properly label both fuel shutoff valves. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 2 September 2003
Resolution: Valves labeled.
Engineering › Bilge Water Management System
Issued 31 July 2003 Resolved
Install a stop valve at the overboard fitting for the forward storage hold submersible electric bilge pump overboard discharge on the port side. LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 2 September 2003
Resolution: Valve installed.
Lifesaving › Lifejacket/PFD (Type I)
Issued 31 July 2003 Resolved
Renew 10 adult type I lifejackets. LEGACY COMPONENT DESC: Condition
Action required: 705 - Other - as specified
Due 31 August 2003
Resolved 31 July 2003
Resolution: 10 Adult lifejackets were rejected. New ones were provided during the inspection.
Electrical › Electrical Distribution System (service)
Issued 31 July 2003 Resolved
Replace the switch for the engine oil pump motor located between the main engines. The switch must be properly rated and also have a ground conductor properly connected. LEGACY COMPONENT DESC: Switch
Action required: 705 - Other - as specified
Resolved 2 September 2003
Resolution: switch installed.
Electrical › Electrical Distribution System (service)
Issued 31 July 2003 Resolved
Replace the portable electric cable installed from the shore tie plug to the generator switch box with a cable rated for permanent shipboard installation. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Resolved 2 September 2003
Resolution: Cable installed.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 31 July 2003 Resolved
Provide guards around the front pulleys of both main engines.
Action required: 705 - Other - as specified
Resolved 2 September 2003
Resolution: guards installed.
Engineering › Fuel Oil Service System
Issued 31 July 2003 Resolved
Properly label both fuel shutoff valves. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Resolved 2 September 2003
Resolution: valves labeled.
Engineering › Bilge Water Management System
Issued 31 July 2003 Resolved
Install a stop valve at the overboard fitting for the forward storage hold submersible electric bilge pump overboard discharge on the port side. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Resolved 2 September 2003
Resolution: valve installed.
Engineering › Bilge Water Management System
Issued 27 May 2003 Resolved
Make high bilge alarms in fwd two compartments operable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2003
Resolved 30 May 2003
Resolution: All bilge alarms operating properly.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 27 May 2003 Resolved
Provide service report for fixed and portable fire fighting equipment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2003
Resolved 30 May 2003
Resolution: Service report provided.
Engineering › Steering Gear System
Issued 27 May 2003 Resolved
Re-pack rudder post. Excessive leakage. No room for tightenning. LEGACY COMPONENT DESC: Rudder Stock
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2003
Resolved 30 May 2003
Resolution: Rudder post repacked, excessive leak stopped
Engineering › Diesel Engine (propulsion-direct drive)
Issued 27 May 2003 Resolved
Provide insulation for exhaust piping from engines through wood exhaust stacks. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2003
Resolved 30 May 2003
Resolution: Insulation provided.
Engineering › Fuel Oil Storage/Transfer System
Issued 27 May 2003 Resolved
Provide bonding wire/strap for fuel tank fills. LEGACY COMPONENT DESC: Tank
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2003
Resolved 30 May 2003
Resolution: Fuel fill pipe adequately bonded.
Engineering › Fuel Oil Storage/Transfer System
Issued 27 May 2003 Resolved
Install emergency reach rod for fuel supply valve from starboard fuel tank. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2003
Resolved 30 May 2003
Resolution: Reach rod installed.
Engineering › Fuel Oil Storage/Transfer System
Issued 27 May 2003 Resolved
Install plug for fuel tank drain line. LEGACY COMPONENT DESC: Tank
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2003
Resolved 30 May 2003
Resolution: Plug installed.
Engineering › Fuel Oil Service System
Issued 27 May 2003 Resolved
Provide metallic piping for fuel system to engines. No hoses in access of 30". LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2003
Resolved 30 May 2003
Resolution: Fuel system adequately piped.
Construction/Loadline › Penetrations
Issued 27 May 2003 Resolved
Make engineroom fume tight, especially around dry exhaust system where it leaves engineroom to exhaust stack.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2003
Resolved 30 May 2003
Resolution: Engineroom made fume tight.
Accommodation/Occupational Safety › Ventilation
Issued 27 May 2003 Resolved
Provide emergency closure devices for natural ventilation system to engineroom.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2003
Resolved 30 May 2003
Resolution: Adequate closures provided.
Stability › Watertight Integrity
Issued 13 May 2002 Resolved
Provide metallic shutoff valve(s) in accordance with 46 CFR 182.720(a)(1) on all penetrations through watertight bulkheads (collision and engine room) made by forward bait tank piping.
Due 30 May 2002
Resolved 20 May 2002
Resolution: Shutoff valves placed on both sides of engine room to sonar space bulkhead and sonar space to forward chain locker (collision) bulkhead.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 May 2002 Resolved
Second page of COI not posted.
Due 13 May 2002
Resolved 13 May 2002
Resolution: Both pages of COI displayed before inspection complete.
Navigation
Issued 13 May 2002 Resolved
No tide tables onboard. LEGACY COMPONENT DESC: Tide tables
Due 13 May 2002
Resolved 13 May 2002
Resolution: Copy of tide tables onboard before inspection complete.
Lifesaving
Issued 13 May 2002 Resolved
Aft, port side lifejacket storage box marked with incorrect number for amount of jackets stowed.
Due 13 May 2002
Resolved 13 May 2002
Resolution: Corrected before inspection complete.
Engineering
Issued 13 May 2002 Resolved
Repair or replace inoperable bilge high level alarm in the sonar room as per 46 CFR 182.530.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2002
Resolution: Alarm replaced and operating properly.
Fire Fighting
Issued 19 May 1999 Resolved
Provide and post operating instructions for the fixed C02 system.
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999
Construction/Loadline
Issued 19 May 1999 Resolved
Provide metallic piping for bilge pump.
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999
Fire Fighting
Issued 27 April 1999 Resolved
Make fixed fire fighting system available for inspection and testing by a marine inspector.
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999
Engineering
Issued 2 October 1997 Resolved
Replace the cowling for both stacks.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Documentation
Issued 23 September 1997 Resolved
Provide proof of paying the 96 user fee of $750.00.
Condition: Unknown
Due 23 September 1997
Resolved 23 September 1997
Documentation
Issued 23 September 1997 Resolved
Get the crew into the drug testing program.
Condition: Unknown
Due 23 September 1997
Resolved 23 September 1997
Accommodation/Occupational Safety
Issued 24 May 1993 Resolved
Provide galley portholes with gaskets and missing dogs.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Engineering
Issued 24 May 1993 Resolved
Provide valve handles for port and starboard main engine cooling water suctions.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Engineering
Issued 24 May 1993 Resolved
Renew fractured starboard main engine raw water filter bowl.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Fire Fighting
Issued 24 May 1993 Resolved
Provide mounting bracket for engineroom CO2, BII fire extinguisher.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Accommodation/Occupational Safety
Issued 24 May 1993 Resolved
Provide valve handle for bow bait tank inlet valve.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Accommodation/Occupational Safety
Issued 24 May 1993 Resolved
Provide valve handle for forepeak bilge suction valve.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Electrical
Issued 24 May 1993 Resolved
Properly wire galley outlets, remove circuit multiplier.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Engineering
Issued 24 May 1993 Resolved
Repair and prove proper operation of port and starboard main engine tachometers.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Lifesaving
Issued 24 May 1993 Resolved
Provide vessel with six (06) adult and one (01) childs P.F.D. Vessel is restricted to a total of sixty-nine (69) passengers on board until corrected.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Engineering
Issued 3 June 1992 Resolved
Repair emergency fuel shut offs so as to make more accessible. Provide heat shields for deck openings.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Lifesaving
Issued 3 June 1992 Resolved
Provide vessel with ten (10) additional USCG approved type I adult life preservers. Vessel may only carry sixty-five (65) persons on board until this requirement is satisfied.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Navigation
Issued 3 June 1992 Resolved
Repair and prove proper operation of anchor light. Vessel is not to operate until this requirement is satisfied.
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Accommodation/Occupational Safety
Issued 3 June 1992 Resolved
Repair first window starboard side passenger compartment.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Construction/Loadline
Issued 29 May 1991 Resolved
FREE-UP BAIT TANK OVERBOARD AND SINK DISCHARGE SEA VALVES IN FOREPEAK.
Condition: Unknown
Due 29 May 1991
Resolved 29 May 1991
Electrical
Issued 29 May 1991 Resolved
PROVIDE GUARDS FOR GLASS LIGHT GLOBES IN ENGINE COMPARTMENT.
Condition: Unknown
Due 29 May 1991
Resolved 29 May 1991
Lifesaving
Issued 29 May 1991 Resolved
RENEW ALL WATERLIGHT BATTERIES.
Condition: Unknown
Due 29 May 1991
Resolved 29 May 1991
Lifesaving
Issued 29 May 1991 Resolved
PROVIDE 9 ADULT LIFE JACKETS IN ADDITION TO THOSE ABOARD PRIOR TO CARRIAGE OF OVER 66 PEOPLE TOTAL.
Condition: Unknown
Due 29 May 1991
Resolved 29 May 1991
Construction/Loadline
Issued 13 December 1990 Resolved
Make transverse bulkheads for engine room watertight at penetrations.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Electrical
Issued 1 May 1990 Resolved
PROPERLY SUPPORT ELECTRICAL WIRING THROUGHOUT VESSEL IN ACCORDANCE WITH IEEE-45.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Electrical
Issued 1 May 1990 Resolved
PROPERLY HARD-WIRE REFRIGERATOR.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Lifesaving
Issued 1 May 1990 Resolved
PROVIDE VESSEL WITH FOUR (04) ADDITIONAL ADULT P.F.D.'S. TOTAL PERSONS ON BOARD IS REDUCED TO SEVENTY-ONE (71) UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Accommodation/Occupational Safety
Issued 1 May 1990 Resolved
RENEW FORWARD PORTLIGHT GLASS.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Accommodation/Occupational Safety
Issued 1 May 1990 Resolved
RENEW STARBOARD AFTER PASSENGER SALON WINDOW.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Engineering
Issued 1 May 1990 Resolved
SUPPORT PORT FUEL LINE TO CLEAR EMERGENCY FUEL SHUTOFF.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Navigation
Issued 12 June 1989 Resolved
REPAIR STEERING GEAR STOP ON PORT SIDE.
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Lifesaving
Issued 12 June 1989 Resolved
RENEW WHITE GRAB LINES TO 3 LIFE FLOATS.
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Fire Fighting
Issued 16 June 1988 Resolved
PROVIDE NOZZLE FOR FIRE HOSE.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Engineering
Issued 16 June 1988 Resolved
REPAIR STBD TACHOMETER ON BRIDGE.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Electrical
Issued 16 June 1988 Resolved
PROVIDE PROTECTIVE GUARD FOR GENERATOR.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Engineering
Issued 16 June 1988 Resolved
STENCIL EMERGENCY FUEL SHUT-OFF.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Construction/Loadline
Issued 27 November 1987 Resolved
FOLLOWING PLANKS REPLACED: FWD 40FT STBD GARBOARD STRAKE ENTIRE PORT GARBOARD STRAKE, 12FT OF FWD STBD SHEER STRAKE 10FT OF 4TH PLANK DOWN STBD SIDE AT AFT BLKHD ENGINE ROOM.
Condition: Unknown
Due 27 November 1987
Resolved 27 November 1987
Navigation
Issued 12 August 1987 Resolved
OVERHAUL AND GAGE STEERING LINKS IN STEERING ROOM AT NEXT DRYDOCK.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Lifesaving
Issued 12 August 1987 Resolved
INSTALL PROPER SIZED WEAK LINK ON LIFEFLOATS.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Engineering
Issued 12 August 1987 Resolved
INSTALL FLAME SCREENS ON BOTH FUEL TANK VENTS.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Lifesaving
Issued 12 August 1987 Resolved
PROVIDE TWO (02) ADULT LIFEJACKETS, WITH LIGHTS. PASSENGERS LIMITED TO 67 UNTIL PROVIDED AND TOTAL PERSONS ABOARD LIMITED TO 73.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Lifesaving
Issued 17 June 1987 Resolved
PROVIDE 10 ADULT LIFEJACKETS WITH LIGHTS. PASSENGERS LIMITED TO 59 UNTIL COMPLETED.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Construction/Loadline
Issued 17 June 1987 Resolved
CLEAN & TREAT INTERNAL HULL IN AREA OUTBOARD OF FUEL TANKS.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Engineering
Issued 17 June 1987 Resolved
INSTALL GUARDS ON FWD END OF MAIN ENGINES BEFORE OPERATION.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Unknown
Issued 17 June 1987 Resolved
INSTALL "CREW ONLY" SIGN ON LADDER TO PILOT HOUSE.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Construction/Loadline
Issued 17 June 1987 Resolved
PLUG BOLT HOLE IN FOREPEAK BULKHEAD BEFORE OPERATION.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Navigation
Issued 17 June 1987 Resolved
OVERHAUL & GAUGE STEERING LINKAGE IN STEERING ROOM AT NEXT DRYDOCK.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Electrical
Issued 17 June 1987 Resolved
WEDGE ALL BATTERIES.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Electrical
Issued 17 June 1987 Resolved
INSTALL BLANK OR CIRCUIT BREAKER IN GALLEY PANEL BOARD.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Lifesaving
Issued 17 June 1987 Resolved
TAG LINE LIFE FLOATS TO EACH OTHER PRIOR TO OPS.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Engineering
Issued 17 June 1987 Resolved
RENEW & DOUBLE CLAMP SALT WATER COOLING HOSE IN SHAFT HOLD.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Fire Fighting
Issued 20 June 1986 Resolved
PROVIDE HOSE RACK FOR FIRE HOSE AND STENCILE FIRE STATION.
Condition: Unknown
Due 20 June 1986
Resolved 20 June 1986
Engineering
Issued 9 August 1985 Resolved
DEMONSTRATE BILGE ALARMS IN BOW COMPARTMENT.
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Construction/Loadline
Issued 9 August 1985 Resolved
REPLACE #2 FRAME, PORT, FROM FORWARD BULKHEAD, BOW COMPARTMENT.
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Construction/Loadline
Issued 9 August 1985 Resolved
REPLACE #8 FRAME STARBOARD, #6,7,8 FRAMES PORT, FROM FORWARD BULKHEAD IN ENGINE ROOM.
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Construction/Loadline
Issued 9 August 1985 Resolved
REPLACE #3 FRAME FROM FORWARD BULKHEAD PORT IN SHAFT COMPARTMENT.
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Documentation
Issued 9 August 1985 Resolved
RENEW DOCUMENT OF VESSEL.
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Construction/Loadline
Issued 25 January 1985 Resolved
MAKE PERMANENT REPAIR TO ROTTED FRAMES IN ENGINEROOM: PORT #1; STBD #4; #4 COMPARTMENT STBD #2,3,4; PORT #1,5; LAZARETTE PORT #3. FRAMES MUST BE REPLACED IN THEIR ENTIRETY, FROM DECK TO KEEL. WITH ORIGNINAL TYPE WOOD OR BETTER.
Condition: Unknown
Due 25 January 1985
Resolved 25 January 1985

Casualty record · 2

22 June 2011Routine · role: Involved in a Marine Casualty · activity 4054808
5 April 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 5780962
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.