Records from 1989 to 2025. Most recent: inspection, 19 May 2025.
Inspection history · 126
19 May 2025
Attraction Vessel Exam · Vessel Attendance · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8121759
7 November 2024
Attraction Vessel Exam · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8024142
16 May 2024
Deficiency Check · Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7905459
3 November 2023
Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7818356
21 April 2023
Attraction Vessel Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7667548
5 October 2022
Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7566577
23 March 2022
Attraction Vessel Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7412525
9 March 2022
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7409598
24 November 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7357343
3 November 2020
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7089290
27 November 2019
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6864130
3 October 2019
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6827833
4 September 2019
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6804138
22 August 2019
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6804799
21 August 2019
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6790838
31 July 2019
Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6761894
2 May 2019
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6867506
9 April 2019
Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6666369
28 February 2019
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6634476
31 January 2019
Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6618070
26 November 2018
Excursion Permit · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6591084
30 October 2018
Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6568351
22 October 2018
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6564723
28 September 2018
Attraction Vessel Exam · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6547781
28 September 2018
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6724688
29 August 2018
Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6526906
27 August 2018
Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6520020
13 December 2017
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6324087
11 June 2016
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5906185
11 May 2016
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5869205
26 August 2015
Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5220874
18 August 2014
Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4958945
6 June 2012
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4333942
1 May 2012
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4299579
13 January 2012
Security Plan Amendment Review - VSP
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4224613
24 August 2011
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4133140
23 July 2011
In-Service Inspection · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4093943
22 July 2011
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4094093
7 February 2011
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3942862
18 March 2009
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3438153
4 March 2009
Type not recorded
No type recorded · Commandant (CG-5P-TI) · Activity 3449924
23 February 2009
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3403938
20 February 2009
Permit to Proceed · Load Line/Change of Employment
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3422673
27 January 2009
Deficiency Check · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3401142
31 October 2008
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3353117
27 September 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3335487
26 September 2008
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3333258
27 August 2008
Examination of Repairs · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3310798
18 June 2008
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3241710
9 April 2008
Annual Inspection · Excursion Permit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3184738
25 January 2008
Type not recorded
No type recorded · Commandant (CG-5P-TI) · Activity 3136225
19 December 2007
Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3118287
5 November 2007
Drydock Extension
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3093637
12 October 2007
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3077601
5 October 2007
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3073188
18 July 2007
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2921516
28 September 2006
Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2789002
27 September 2006
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2788474
24 May 2006
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2623452
17 May 2006
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2652085
20 July 2005
Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2434206
4 May 2005
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2349057
30 November 2004
MTSA Verification · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2246005
27 November 2004
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2248722
20 September 2004
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2200625
15 September 2004
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2182089
11 September 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2193019
11 September 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2193208
16 July 2004
Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2138228
2 July 2004
Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2119014
20 May 2004
Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2073472
19 March 2004
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2027575
17 August 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1878288
17 July 2003
Excursion Permit · Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1849077
23 May 2003
Internal Structural Exam · Excursion Permit
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1797852
1 May 2003
Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1784603
18 April 2003
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1776044
16 August 2002
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1665990
25 May 2002
In-Service Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1622148
9 May 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1614939
8 May 2002
Excursion Permit · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1614191
15 May 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1399619
9 May 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1063333
11 April 2001
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1426634
18 October 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1055151
30 April 2000
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1404933
6 August 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1352065
5 August 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1110410
28 April 1999
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1447959
30 March 1999
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1372556
27 May 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 792151
6 May 1998
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 791272
22 April 1998
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1424575
17 November 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1335380
11 June 1997
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1111236
21 May 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1110173
23 April 1997
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1437232
19 March 1997
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1104729
15 April 1996
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1405893
11 July 1995
Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1192940
24 April 1995
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1183726
21 September 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 31894
20 September 1994
Excursion Permit
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 869736
20 September 1994
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 870629
19 September 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 870062
6 September 1994
Excursion Permit
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 870835
12 August 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1367148
1 June 1994
Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 861034
28 April 1994
COI Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1425420
6 December 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 852493
29 September 1993
Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1154789
22 September 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 669030
1 September 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 118984
21 July 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1154500
20 July 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 669031
24 June 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 100238
10 May 1993
Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 827179
16 March 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 841406
3 March 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 840825
17 February 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1146925
2 October 1992
Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1257989
3 September 1992
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1252232
24 August 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1456073
24 June 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1395856
5 March 1992
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 943502
9 June 1989
Uninspected Towing Vessel
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1042713
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 19 May 2025
Resolved
Existing structure previously approved will be considered satisfactory so long as it is maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection. Excessive corrosion was observed on the starboard lifeboat deck and port top most deck. Restrict passenger access to those areas. 46 CFR 92.01-90 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 18 June 2025
Resolution: Recieved evidence that passenger access was restricted to these areas.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 May 2025
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. An active lube oil leak was observed from the gravity tank creating a fire/slip hazard in ER.
46 CFR 92.05-1 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 24 July 2025
Resolution: No leaks detected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 May 2025
Resolved
Existing structure, arrangements, materials, and facilities, previously accepted or approved will be considered satisfactory so long as they are maintained in a suitable condition to the satisfaction of the [name withheld] gas cylinders (propane and oxygen) were observed unsecured and stored on the stern gun deck. 46 CFR 111.75-15 16c
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 18 June 2025
Resolution: Recieved evidence propane and oxygen bottles were removed.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 19 May 2025
Resolved
Each space used by passengers or crew must be fitted with lighting that provides for a safe habitable and working environment under normal conditions. MI id'd
cargo hold #2 with non-functional lighting fixtures. 46 CFR 111.75-15 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 18 June 2025
Resolution: Recieved evidence that lighting was replaced.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 19 May 2025
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10.
Vessel was unable to provide documentation of the most recent annual servicing for onboard fire protection equipment.
46 CFR 91.25-20(a)(1) 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 18 June 2025
Resolution: Recieved evidence of annual servicing.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 November 2023
Resolved
All fire extinguishers aboard the vessel were past annual servicing date; servicing is required for all fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2023
Resolved 7 November 2023
Resolution: Vessel serviced all fire extinguishers.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 5 October 2022
Resolved
Vessels of 100 GT and over, contracted for on or after January 1, 1941 but prior to November 19, 1952, must meet the following requirements: Existing structures and arrangements previously approved will be considered satisfactory so long as they are maintained in a suitable condition to the satisfaction of the OCMI. Vessel engine room has oil dripping onto entry pway upper level from lube oil tank and under SSTGs on the lower level, which presents a slipping hazard to ship volunteer crew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 April 2023
Resolution: Oil leak secured
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 October 2022
Resolved
For inspection procedures of lifesaving equipment, see subchapter W. - Operational readiness, maintenance, and inspection of life saving equipment. Two life rings found fitted with floating water light, which was left hanging or laying on nearby brackets, and not in the manufacturers properly sized mounting cradle.
46 CFR 91.25-15 / 46 CFR 199.190
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 April 2023
Resolution: Ring buoys not required to have floating water lights. All observed ring buoys were stored properly.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 5 July 2019
Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he deems necessary to be assured of the safety and seaworthiness of the vessel.
Prior to Coast Guard inspections in the Engine room, bulk sampling must be conducted by a State licensed asbestos inspector utilizing polarized light microscopy analysis, as well as air sampling for asbestos. Results of the testing and sampling shall be provided to this office. If asbestos is identified in the samples, the hazard must be mitigated appropriately in accordance with NESHAP standards (40 CFR 61 Subpart M) and those standards found in NVIC 06-87.
Action required: 705 - Other - as specified
Resolved 23 March 2022
Resolution: Air sampling showed no particles, bulk sample proved not friable. Vessel implemented a asbestos op plan and has encapsulated all disturbed areas.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 28 September 2018
Resolved
Provide a fire control plan.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2018
Resolved 31 October 2018
Resolution: Evacuation and emergency plans added to SMS
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 September 2018
Resolved
Provide a list of amounts, types and stowage of flammable liquids.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2018
Resolved 31 October 2018
Resolution: List created and being maintained.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 September 2018
Resolved
Provide rail courses on railing on the folksal aft rail port and stbd inboard of the ladders to the main deck.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2018
Resolved 31 October 2018
Resolution: Nets added to areas of concern
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 September 2018
Resolved
Prove annual testing or servicing of all portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2018
Resolved 31 October 2018
Resolution: Serviced by High Seas Trading 10/12/18
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 September 2018
Resolved
Prove proper operation of all fire and smoke detectors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2018
Resolved 31 October 2018
Resolution: List of all detectors created, inop detectors replaced, will go on quarterly testing schedule.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 11 May 2016
Resolved
Provide Portable Fire Extinguisher Service Certificate.
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 24 June 2016
Resolution: Portable Fire Extinguishers were serviced.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 11 May 2016
Resolved
Provide Cargo Boom Service/Inspection Report for Booms # 5,6,9,10,11, and 12.
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 24 June 2016
Resolution: Nondestructive testing was done by Tucker's Technical of San Pedro, ca.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 26 August 2015
Resolved
PROVIDE EMERGENCY OPERATION PLAN FOR ATTRACTION VESSEL.
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 4 September 2015
Resolution: PLAN WAS PROVIDED.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 August 2015
Resolved
PROVIDE FIXED CO2 SYSTEM SERVICE REPORT.
Action required: 705 - Other - as specified
Due 26 October 2015
Resolved 11 May 2016
Engineering › Steam Boiler (propulsion) › Firewall Tube
Issued 23 July 2011
Resolved
Repair Stbd propulsion boiler.
Action required: 705 - Other - as specified
Due 26 August 2011
Resolved 11 April 2012
Resolution: Completed hydro of 125% and operational testing of the boiler.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 7 February 2011
Resolved
Repair/Replace Port cargo boom DC motor foward of the house main deck. Port Cargo Boom restricted from use until proper replacement/repairs are made.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 September 2011
Resolved 18 July 2012
Resolution: Replaced.
Lifesaving › Lifeboat › Hull
Issued 18 March 2009
Resolved
Repair or replace the #1 port motor lifeboat due to holes in the hull. The boat must be removed from the davits, taken ashore or loaded on deck, and stripped for inspection by an attending marine inspector prior to commencing repairs.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2009
Resolved 6 July 2009
Resolution: Lifeboat replaced and inspected. Weight test to be conducted.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 18 March 2009
Resolved
Provide a properly installed and operating Marine Sanitation Device per 33 CFR 159 for the sanitation device and 46 CFR 56 for the piping systems.
Action required: 705 - Other - as specified
Due 18 June 2009
Resolved 24 June 2009
Resolution: Omnipure Tech rep verified MSD was operating IAW manufactures guidelines.
Construction/Loadline › Penetrations › Pipe Flange
Issued 18 March 2009
Resolved
Provide a properly installed overboard connection for the sewage overboard shore connection on the starboard side.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2009
Resolved 1 June 2009
Resolution: Provided.
Engineering › Feedwater/Condensate Water System › Condensor
Issued 6 March 2009
Resolved
Make permanent repairs to main condenser overboard pipe from condenser to overboard valve. Submit repair proposal to Cognizant OCMI prior to commencing work. A One-way voyage from San Diego to Long Beach in authorized.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2009
Resolution: New condenser overboard installed and tested.
Lifesaving › Launching Appliances › Winch
Issued 6 March 2009
Resolved
Make permanent repairs to wasted lifeboat winch foundations on Port & Stbd boat decks. Replace deck as necessary to good metal. Welders shall be USCG, ABS, or AWS certified to the satisfaction of the cognizant OCMI. A stationary static overload test iaw 46 CFR 160.032-5(b)(2), at 2.2 times the working load shall verify repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2009
Resolution: Davit weight tested conducted IAW 46 CFR 160.032-5(b)(2)
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 6 March 2009
Resolved
Remove mud/sludge from Cargo Hold # 1 Bilge Well. Propose cleaning schedule to be completed NLT 06MAR10.
Condition: Improper/Lack of Maintenance
Due 6 March 2010
Resolved 21 April 2010
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 6 March 2009
Resolved
Remove mud/sludge from Forward Engine Room Cofferdam. Propose cleaning schedule to be completed NLT 06MAR10.
Action required: 705 - Other - as specified
Due 6 March 2010
Resolved 21 April 2010
Construction/Loadline › Hull › Side Shell
Issued 6 March 2009
Resolved
Conduct expansive UT grid for side shell plate thickness in way of Stbd G Strake 9-10 and Port G Strake 8-9 ( Five plates beneath Sheer)
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 5 June 2009
Resolution: Received final report, see activity for summary
Construction/Loadline › Hull › Hull Plating
Issued 6 March 2009
Resolved
Submit final gauging report prior to receiving credit for hull exam.
Action required: 705 - Other - as specified
Resolved 5 June 2009
Resolution: Received final report, see documenation for details
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 23 February 2009
Resolved
Remove rust/scale/flakes from Aft Engine Room Cofferdam. Propose cleaning schedule to be completed NLT 06MAR10.
Action required: 705 - Other - as specified
Due 6 March 2010
Resolved 21 April 2010
Electrical › Electric Generation Source (service) › Panelboard
Issued 31 October 2008
Resolved
Provide a single line electrical diagrams for approval of the auxiliary generator system located in the forecastle. The two auxiliary generators may not be energerized until the electrical systems associated with the auxiliary generators are are approved.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 30 January 2009
Resolution: Provide and approved by MSC.
Engineering › Steam Boiler (propulsion) › Generating tube
Issued 27 August 2008
Resolved
Make the waterside available for inspection by an attending USCG marine inspector after satisfactory hydro-test.
Action required: 705 - Other - as specified
Due 30 November 2008
Resolved 31 October 2008
Resolution: Completed waterside inspection of the starboard main propulsion boiler - all satisfactory.
Engineering › Steam Boiler (propulsion) › Generating tube
Issued 27 August 2008
Resolved
Hydrotest the starboard propulsion boiler to 125% MAWP or as required by 46 CFR 61.05-10 following repairs to leaking tubes.
Action required: 705 - Other - as specified
Due 27 September 2008
Resolved 22 October 2008
Resolution: Conducted satisfactory hydrostatic test to 525 psi. This was 100% MAWP. Boiler may be derated due to age, condition and needs to the vessel.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 21 May 2008
Resolved
Provide a valid Safety Radio Certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2008
Resolved 3 July 2008
Documentation › Certificates/Documents › FCC SSL
Issued 21 May 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2008
Resolved 3 July 2008
Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 21 May 2008
Resolved
Provide two self-activating smoke signals for lifebuoys on port and stbd bridge wings as required by 46 CFR 199.70(a)(1)(v).
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2008
Resolved 3 July 2008
Navigation › Piloting/Steering › Marine Charts
Issued 21 May 2008
Resolved
Provide updated charts for area of operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2008
Resolved 3 July 2008
Engineering › Steam Boiler (propulsion) › Piping
Issued 9 April 2008
Resolved
Repair hole in the main condensor overboard pipe located port side, lower level, upsteam of the flexible joint at the overboard discharge skin valve. This must be completed prior to vessel getting underway under her own power. A temporary repair, approved by an attending marine inspector, may be acceptable if the pipe is be replaced at next scheduled drydocking in October 2008.
Action required: 705 - Other - as specified
Due 9 May 2008
Resolved 9 April 2008
Fire Fighting › Fire Main › Condition
Issued 9 April 2008
Resolved
Repair wasted and holed fire main to aft peak ballast tank supply pipe located at the steam fire pump in the lower level, port side. This must be repaired prior to the vessel getting underway under her own power.
Action required: 705 - Other - as specified
Due 9 May 2008
Resolved 9 July 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 9 April 2008
Resolved
Provide a mounting bracket for the BII portable fire extinguisher in the emergency diesel generator room.
Action required: 705 - Other - as specified
Due 9 May 2008
Resolved 9 July 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 9 April 2008
Resolved
Provide a portable B-CII fire extinguisher in the IC Battery Room located above the emergency diesel generator room.
Action required: 705 - Other - as specified
Due 9 May 2008
Resolved 9 July 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 April 2008
Resolved
Provide battery hold downs for the IC and Emergency Diesel batteries in the IC Battery Room located above the emergency diesel generator room.
Action required: 705 - Other - as specified
Due 9 May 2008
Resolved 18 June 2008
Resolution: Provided.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 9 April 2008
Resolved
Provide insulating lagging for the emergency diesel exhaust pipe.
Action required: 705 - Other - as specified
Due 9 May 2008
Resolved 18 June 2008
Resolution: Provided.
Engineering › Steam System (auxiliary) › Piping
Issued 9 April 2008
Resolved
Repair leaking plug fitting on the bilge sea-suction seachest steam blow-out line located on the port side lower level of the engine room.
Action required: 705 - Other - as specified
Due 9 May 2008
Resolved 9 July 2008
Engineering › Steam Boiler (propulsion) › Valve, Superheater Safety
Issued 9 April 2008
Resolved
Adjust the starboard boiler superheater steam safety hand relieving gear so that it works effectively.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 3 July 2008
Electrical › Electrical Distribution System (service) › Switchboard
Issued 9 April 2008
Resolved
Remove the miscelaneous gear from behind the turbine generator switchboard.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 18 June 2008
Resolution: Removed.
Stability › Intact Righting Energy › General
Issued 9 April 2008
Resolved
Repair wasted aft peak ballast tank supply piping in way of the steam fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2008
Resolved 18 June 2008
Resolution: Repaired.
Accommodation/Occupational Safety › Ventilation › General
Issued 9 April 2008
Resolved
Open the sealed air vent on the CO2 storage room.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 9 July 2008
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 9 April 2008
Resolved
Properly support the refrigerant piping from the freezer compressor units located in the engine room reefer deck level.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 18 June 2008
Resolution: Properly supported.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 April 2008
Resolved
Provide globe and guards for all incandescant lights in the engineroom.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 18 June 2008
Resolution: Provided.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 9 April 2008
Resolved
Provide permanently installed, properly sized and type cable for all flourescent lights located in the engine room and workshop spaces forward of the engineroom.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 18 June 2008
Resolution: Provided.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 9 April 2008
Resolved
Provide suitable guards for all flourscent lamps with bare bulbs located in the engine room and workshops forward of the engine room.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 18 June 2008
Resolution: Provided.
Engineering › Bilge Water Management System › Piping
Issued 9 April 2008
Resolved
Replace the PVC piping from the auxiliary bilge pump to the overboard connection with steel pipe. This may be completed at next schedule drydock.
Action required: 705 - Other - as specified
Due 31 January 2009
Resolved 27 January 2009
Resolution: Replaced PVC piping from the auxilary bilge pump to the overboard connection with steel pipe.
Construction/Loadline › Structures › Trunk
Issued 9 April 2008
Resolved
Repair the cracked exhaust stack supports located at the top of the exhaust stack. This item may be completed at the next drydock.
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 22 October 2008
Fire Fighting › Fire Main › Condition
Issued 9 April 2008
Resolved
Crop and renew the wasted steam fire pump vertical support. This may be completed at next drydock.
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 22 October 2008
Engineering › Fuel Oil Service System › Piping
Issued 9 April 2008
Resolved
Properly mount the cushioning pipe for the fuel oil service pump located lower level port side forward.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 18 June 2008
Resolution: Mounted correctly.
Lifesaving › Lifeboat › Inherent Buoyancy
Issued 18 July 2007
Resolved
Repair #3 air floatation tank in the #2 lifeboat. The number of other persons in the crew is reduced by 37 until the #2 lifeboat is repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 18 July 2007
Lifesaving › Lifeboat › Handholds/Handrails
Issued 18 July 2007
Resolved
Repair the #2 lifeboat outside hull grab rail on the starboard side of the boat. The number of other persons in the crew is reduced by 37 until the #2 lifeboat is repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 18 July 2007
Lifesaving › Lifeboat › Handholds/Handrails
Issued 18 July 2007
Resolved
Repair the #4 lifeboat grab rail where it is connected to the boat hull, port side forward.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 18 July 2007
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 9 May 2007
Resolved
Repair #3 lifeboat brake. During wet brake test brake did not stop boat. To be completed by 12 July 2007 to the satisfaction of the attending marine inspector. 46CFR 199.199. Vessel may not carry any persons in addition to crew and other persons in addition to crew is reduced to 11.
Action required: 705 - Other - as specified
Due 12 July 2007
Resolved 2 July 2007
Electrical › Electrical Distribution System (service) › Switchboard
Issued 24 May 2006
Resolved
Replace missing handrails behind switchboard per 46 CFR 50.20-35(a) and Subchapter J as this is a personnel hazard.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2006
Resolution: Corrected during the examination.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 24 May 2006
Resolved
Repair portside AC generator exhaust leak per 46 CFR 58.10-5(d)
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 May 2006
Resolved
Provide guards on rotating machinery on both AC Generators and in the steering gear room per 46 CFR 58.01-20.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2006
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 24 May 2006
Resolved
Repair leaking fuel line on port AC generator per 46 CFR 56.50-70(b).
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 24 May 2006
Resolved
Provide directions for emergency generator CO2 system per 46 CFR Subchapters I and H.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2006
Engineering › Steam Turbine (propulsion) › Expansion Joint
Issued 1 October 2004
Resolved
Renew main condenser inboard expansion joint at circ pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 January 2005
Resolved 4 May 2005
Resolution: Verified that a new expansion joint was installed.
Fire Fighting › Fire Main › Condition
Issued 1 October 2004
Resolved
Renew fire pump inlet expansion joint and elbow piping between sea sea valve and expansion joint
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 January 2005
Resolved 4 May 2005
Resolution: Verified that a new expansion joint had been installed.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 1 October 2004
Resolved
Verify operation of stern tube salt water emergency cooling to shaft journal.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 January 2005
Resolved 4 May 2005
Resolution: Conducted a satisfactory test of the shaft bearing cooling water system.
Documentation › Certificates/Documents › Coastwise Load Line Certificate
Issued 1 October 2004
Resolved
Complete Coastwise Loadline Renewal
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 December 2004
Resolved 15 November 2004
Resolution: Received Loadline Certificate from ABS.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 20 September 2004
Resolved
Withdraw tailshaft so that an inspection can be completed on the aftermost bearing and seal journal areas of the shaft.
This item must be completed before credit is given for drydock IAW OCMI letter 16711/050-04 dated Aug 17, 2004.
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 22 September 2004
Resolution: Tailshaft removed and examined. Shaft journal cleaned and examined. All SAT.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 16 August 2002
Resolved
Issued requirement for vessel to review, amend and submit SOPEP for approval to COMDT and provide copy of approval letter to OCMI within 60 days. VESSEL IS PERMITTED TO SAIL WITH PASSENGERS ONLY DURING THE PREVIOUSLY SCHEDULED 17/18AUG AND 14/15SEP TRIPS.
LEGACY COMPONENT DESC: SOPEP
Due 16 October 2002
Resolved 16 October 2002
Engineering
Issued 15 May 2001
Resolved
Identify cause of fuel oil leak in aftermost section of shaft alley. Submitrepair proposal to congnizant OCMI.
Condition: Unknown
Due 25 May 2001
Resolved 29 April 2002
Resolution: Cleared outstanding requirement from MSO San Diego inspection.
Fire Fighting
Issued 30 April 2000
Resolved
SUBMIT PLANS FOR FWD GENERATOR CO2 SYSTEM. AND CONDUCT OPERATIONAL INSPECTION BY QUALIFIED 3RD PARTY VENDOR.
Condition: Unknown
Due 31 December 2000
Resolved 8 May 2002
Electrical
Issued 30 April 2000
Resolved
PROVIDE GUARD AROUND EXPOSED ROTATING ENDS OF THE #1 & #2 SSTG'S.
Condition: Unknown
Due 30 November 2000
Resolved 8 May 2002
Lifesaving
Issued 30 April 2000
Resolved
RENEW LIFEBOAT FALLS.
Condition: Unknown
Due 31 March 2001
Resolved 8 May 2002
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 28 April 1999
Resolved
PULL TAILSHAFT FOR INSPECTION AT NEXT SCHEDULED DRYDOCK.
Condition: Unknown
Due 30 March 2004
Resolved 22 September 2004
Resolution: Shaft removed & inspected, SAT
Engineering
Issued 28 April 1999
Resolved
PROVIDE OCMI WITH A PROPOSED SCHEDULE TO MAKE INTEGRAL FUEL TANKS AVAILABLEFOR INSPECTION.
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Engineering
Issued 28 April 1999
Resolved
RENEW FAULTY FORWARD DRUM SAFETY ON PORT BOILER.
Condition: Unknown
Due 28 April 1999
Resolved 24 May 1999
Fire Fighting
Issued 27 May 1998
Resolved
PROVIDE PROOF OF TESTING OF THE FIXED C02 ALARMS.
Condition: Unknown
Due 26 June 1998
Resolved 7 August 1998
Documentation
Issued 22 April 1998
Resolved
PROVIDE A VALID SAFETY RADIO TELEPHONE/TELEGRAPH CERTIFICATE.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Fire Fighting
Issued 22 April 1998
Resolved
COMPLETE SERVICING OF FIXED CO2 SYSTEM AS PER USCG, NPFA, AND MANUFACTURE STANDARDS. _x001C_
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Lifesaving
Issued 22 April 1998
Resolved
Label emergency escape hatch from shaft alley so that it is visible when standing in shaft alley.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Lifesaving
Issued 22 April 1998
Resolved
PROVIDE ONE ADDITIONAL LIFERAFT FOR THE VESSEL.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Engineering
Issued 22 April 1998
Resolved
Demonstrate operation of hand relieving gear for both boiler steam safety valves on the port propulsion boiler. This must be done before operating vessel underway.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Electrical
Issued 22 April 1998
Resolved
Prove proper operation of low lube oil pressure shut down for #1 S/S steam turbine generator. This item must be completed before operating vessel underway.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Engineering
Issued 22 April 1998
Resolved
Demonstrate proper operation of starboard boiler superheater steam safety valve hand relieving gear. This must be completed before vessel operates underway.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Electrical
Issued 22 April 1998
Resolved
Demonstrate proper operation of emergency diesel generator under load. This must be completed before vessel operates underway.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Lifesaving
Issued 22 April 1998
Resolved
PROVIDE LIGHTS FOR ALL IMMERSION SUITS AND ALL LIFE JACKETS REQUIRING LIGHTS.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Documentation
Issued 23 April 1997
Resolved
Provide Shipboard Oil Pollution Emergency Plan (SOPEP) per 33CFR151.09 and 33CFR151.25 prior to getting vessel underway but not later than 31MAY97.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Engineering
Issued 23 April 1997
Resolved
MAKE DC HEATER AND SHIP SERVICE AIR FLASK AVAILABLE FOR INTERNAL EXAM.
Condition: Unknown
Due 23 May 1997
Resolved 21 May 1997
Lifesaving
Issued 23 April 1997
Resolved
Conduct lifeboat weight test in presence of USCG Marine Inspector prior to getting vessel underway but not later than 31MAY97.
Condition: Unknown
Due 31 May 1997
Resolved 7 May 1997
Engineering
Issued 23 April 1997
Resolved
Remove damaged material and repair brick in way of bottom five tubes after side port boiler furnace to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Lifesaving
Issued 23 April 1997
Resolved
Provide general alarm that is audible in all spaces normally accessible to passengers and crew prior to getting vessel underway but not later than 31MAY97.
Condition: Unknown
Due 31 May 1997
Resolved 21 May 1997
Engineering
Issued 23 April 1997
Resolved
Provide insulation or spray shielding on flanged joints of fuel oil supply pipes in way of starboard boiler front.
Condition: Unknown
Due 23 May 1997
Resolved 21 May 1997
Documentation
Issued 23 April 1997
Resolved
Provide Certificate of Financial Responsibility (Water Pollution) prior to getting vessel underway but not later than 31MAY97.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Engineering
Issued 23 April 1997
Resolved
MAKE PORT AND STARBOARD BOILER AVAILABLE FOR FIRE/WATERSIDE EXAM.
Condition: Unknown
Due 23 May 1997
Resolved 21 May 1997
Documentation
Issued 23 April 1997
Resolved
Provide proof of enrollment in an acceptable drug testing program with a description of random testing procedures used by program prior to getting vessel underway but not later than 31MAY97.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Documentation
Issued 15 April 1996
Resolved
Provide Oil Transfer Procedures.
Condition: Unknown
Due 29 April 1996
Resolved 17 April 1996
Fire Fighting
Issued 24 April 1995
Resolved
PROVE THE PROPER OPERATION OF THE AFT FIRE PUMP AND THE RELIEF VALVE.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Electrical
Issued 24 April 1995
Resolved
PROVE THE PROPER OPERATION OF THE EMERGENCY GENERATOR LOW LUBE OIL ALARM AND TRIP.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Engineering
Issued 28 April 1994
Resolved
PROVIDE FIXED HARD PIPING PROPERLY INSTALLED ON THE OILY WATER SEPARATOR._x001C_ UNTIL CORRECTED ALL OILY WATER SHALL BE RETAINED ON BOARD FOR DISCHARGE TO A SHORE RECEPTION FACILITY.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Documentation
Issued 28 April 1994
Resolved
PROPERLY POST ALL DOCUMENTS ISSUED THAT ARE REQUIRED TO BE POSTED.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Navigation
Issued 28 April 1994
Resolved
CORRECT ALL CHARTS AND NAVIGATION PUBLICATIONS FOR THE ROUTE INTENDED.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Lifesaving
Issued 28 April 1994
Resolved
PROPERLY SECURE FOR SEA ALL LOOSE GEARS IN CARGO HOLDS, CREW WORK AND ACCOMODATION SPACES.
Condition: Unknown
Due 24 May 1994
Resolved 24 May 1994
Accommodation/Occupational Safety
Issued 28 April 1994
Resolved
PROPERLY INSTALL AND PROVE THE PROPER OPERATION OF THE COAST GUARD APPROVEDMARINE SANITATION DEVICE SYSTEM(MSD).
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Construction/Loadline
Issued 28 April 1994
Resolved
PROVIDE METALLIC SHUT-OFF VALVE AS CLOSE AS POSSIBLE TO THE BULKHEAD ON 8" PLASTIC PIPING PENETRATING THE MAIN TRANVERSE WATERTIGHT BULKHEAD AT FRAME 95._x001C_
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Electrical
Issued 28 April 1994
Resolved
PROVE THE PROPER OPERATION OF THE EMRGENCY GENERATOR LOW LUBE OIL ALARM & SHUTDOWN AND HIGH TEMPERATURE JACKET COOLING WATER ALARM PRIOR TO DEPARTURE.
Condition: Unknown
Due 24 May 1994
Resolved 24 May 1994
Electrical
Issued 28 April 1994
Resolved
PROVIDE A CURRENT ONE-LINE ELEMENTARY WIRING DIAGRAM THAT INCLUDE ALL THE MODIFICATION AND ADDITION OF VARIOUS NEW EQUIPMENT ON BOARD.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Electrical
Issued 28 April 1994
Resolved
PROPERLY LABEL THE LAUNDRY ROOM CIRCUIT.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994