Inspection history · 57
1 July 2026
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8420737
11 June 2026
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8401297
1 June 2026
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8381985
21 March 2026
PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8329647
9 March 2026
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8322965
2 March 2026
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8324406
10 February 2026
ISPS Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8308056
23 December 2025
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8286862
21 November 2025
ISPS Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8272111
12 October 2025
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8249573
7 April 2025
PSC A
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8103134
26 March 2025
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8092806
18 November 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8036637
16 July 2024
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7959588
9 July 2024
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7950062
12 April 2024
PSC A
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7890862
24 December 2023
PSC A
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7841353
4 December 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7833318
13 October 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7808023
11 July 2023
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7739481
6 July 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7734643
20 June 2023
PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7718655
19 November 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7597140
15 November 2022
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7594643
20 October 2022
PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7578778
13 October 2022
PSC B · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7576452
11 October 2022
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7574950
29 July 2022
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7519448
26 July 2022
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7517168
22 July 2022
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7513711
15 July 2022
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7507309
21 April 2022
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7433190
27 November 2021
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7358499
19 November 2021
PSC B · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7353777
5 May 2021
PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7189744
16 December 2020
PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7112668
5 August 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7024725
15 June 2020
PSC A
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6977152
20 May 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6956450
17 December 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6875696
26 November 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6861414
22 May 2019
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6688347
18 December 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6598743
3 December 2018
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6591012
26 October 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6575962
11 June 2018
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6436932
10 November 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6304643
4 November 2017
Administrative Inspection · PII Safety Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6300280
27 September 2017
ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6274694
20 September 2017
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6266732
2 May 2017
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6136290
21 April 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6127533
27 March 2017
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6113510
29 September 2016
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6011305
5 April 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5847810
28 March 2016
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5840000
22 February 2016
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5819746
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 1 June 2026
Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be working order and ready for immediate use. Vessel self reported starboard side life boat to be inoperable.
74SOLAS(20)III/20.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2026
Resolved 2 July 2026
Resolution: Vessel made satisfactory repair of stbd lifeboat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 22 March 2026
Resolved
Before the ship leaves port and at all times durring the voyage, all life-saving appliances shall be in working order and ready for immediate use. #1 starboard lifeboat found inoperable due to stern tube failure.
Action required: 10 - Deficiency Rectified
Due 22 March 2026
Resolved 22 March 2026
Resolution: Recieved findings report # 1442.0 and stort term CSSE cert for the starboard lifeboat. Repairs are scheaduled for 04APR2026 in Mobile, AL.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 9 July 2024
Resolved
Guard rails fitted on freeboard decks shal have at least three courses.
03 separate courses on freeboard deck railings wasted and separated from stantions.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 July 2024
Resolution: Upon review of ABS Class Report, all repairs have been found to be satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 July 2024
Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be insured.
PSCO discovered light improperly installed into fixed wiring without class approval.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 July 2024
Resolution: Light was removed from fixed wiring system.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 October 2022
Resolved
03107- Watertight doors or ramps of satisfactory construction may be fitted to internally subdivide large cargo spaces, provided that the administration is satisfied that such doors or ramps are essential. PSCO observed watertight door between cargo hold 2 and 3 did not close fully.
74 SOLAS (04) II-1/25-9.4-17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2022
Resolution: Upon review of the Class survey, vessel has been cleared of the deficiency
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 13 October 2022
Resolved
07130- Such penetrations shall be suitably isolated by extension of the insulation of the same level of the division. PSCO observed high voltage electrical cables for newly installed ballast water treatment system penetrating a class A boundary into the ECR without proper insulation.
74 SOLAS (04) II-2/9.3.1- 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2022
Resolution: Upon review of the Class survey, vessel has been cleared of the deficiency
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 October 2022
Resolved
07105- Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. PSCO observed escape trunk in machinery space had an inadequate self closing door.
74SOLAS(97) II-2/47.1-10c
Action required: 10 - Deficiency Rectified
Resolved 13 October 2022
02 - Structural Conditions › N/A - No Subsystem › Spaces in cargo areas
Issued 13 October 2022
Resolved
02125- The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in respects shall remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed over 40 cracks from 1 inch to 6 feet long throughout cargo tunnel. In addition, a large amount of wastage was found on support structures, cargo hold stiffeners and on top of conveyor belt.
74SOLAS(04) I/11(a)-40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 October 2022
Resolution: Upon review of the Class survey, vessel has been cleared of the deficiency
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 November 2021
Resolved
In a ship in which fuel is used, the arrangements for storage, distribution and utilization of the fuel shall be such as to ensure the safety of ship and persons on board. PSCO observed leak in the bunker line.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 November 2021
Resolution: Sector Charleston received class report attesting to the repairs
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 November 2019
Resolved
THE FUNCTION OF THE DETECTION SYSTEM SHALL BE PERIODICALLY TESTED BY MEANS OF EQUIPMENT PRODUCING HOT AIR AT THE APPROPRIATE TEMPERATURE. DURING THE EXAM, PSCO WITNESSED CREW TESTING HEAT DETECTORS WITH A HEAT GUN IN WHICH CREW COULD NOT PROVE WAS THE APPROPRIATE TEMPERATURE FOR HEAT DETECTORS INSTALLED ON VESSEL.
16ac
74SOLAS(97CONS)CH II-2/13.1.13
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 December 2019
Resolved 17 December 2019
Resolution: The Operating Company has provided with the vessel with a apparatus, SOLO heat detector tester, for testing of the heat detectors.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 22 May 2019
Resolved
11107 - Rescue boat shall be stowed in a state of continuous readiness for launching in not more than 5 minutes. Rescue boat would not start. Battery replaced and had 3 successful starts. (SOLAS 74 Ch. III Reg 14.1)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 22 May 2019
Resolution: Battery was replaced.
Fire Fighting › Fire Main › Condition
Issued 4 November 2017
Resolved
0730 - Appliances (General Equipment) - Maintenance, testing and inspections shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. Three soft patches were observed on vessels fire main in the main engineering space. 74 SOLAS 14 CONS CH II-2/ Reg 14.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 November 2017
Resolution: Received vessel class reports. See documents
Construction/Loadline › Hull › Side Shell
Issued 28 March 2016
Resolved
1299-Other (LoadLines)-Repairs should meet the requirements of a new shop to the satisfaction of the Administration. Two area on the port side of the hull seem to have repairs no in accordance to class rules ICLL Article 10
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 5 April 2016
Resolution: Class
Recommended repairs be done at next dry dock in 2018 and Flag concurs