02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 January 2025
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Collision bulkhead has open hole from prior penetrations. Seal open penetrations in collision bulkhead and make watertight. 46 CFR 179.320(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2025
Resolved 14 February 2025
Resolution: Vessel provided photo evidence of sealed penetrations.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 27 January 2025
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Both ER bait motor electrical wiring entering the motor terminal box were missing a cable gland and insulation protecting the wire from chaffing on the threaded penetration holes. Install cable gland and properly secure cable entrance into motor. Operation of motors are restricted until rectification of this deficiency. 46 CFR 183.220
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2025
Resolved 14 February 2025
Resolution: Vessel replaced aft motor. Installed cable glands and insulated cables.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 27 January 2025
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Replace EPRIB hydrostatic release unit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2025
Resolved 14 February 2025
Resolution: Vessel replaced EPIRB hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 January 2025
Resolved
Each ring life buoy on a vessel must:(1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Ring life buoy is worn and life line is not buoyant type. Replace ring life buoy and life line. 46 CFR 180.70
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2025
Resolved 14 February 2025
Resolution: Vessel renewed life ring and replaced life line.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 27 January 2025
Resolved
Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Two twist on connector found in bridge electrical circuitary. Remove twist on connectors and connect wiring with UL 486A type wire connector. 46 CFR 183.340(i)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2025
Resolved 14 February 2025
Resolution: Vessel removed twist on connectors. Replaced with approved type.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 January 2025
No resolution recorded
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. 11th frame Port Side Engine Room was found split with advanced decay. Vessel is to submit repair proposal for repair to attending marine inspector. Deficiency rectification is extended until dry dock 2025 completion. 46 CFR 176.700(a)
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 4 December 2023
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Tank room bulkhead has (8) holes that are not watertight between the engineroom. Seal holes to ensure watertight integrity of the engineroom and tankroom bulkhead. 46 CFR 179.320(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2023
Resolved 4 December 2023
Resolution: Vessel provided evidence showing sealing of bulkhead holes.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 October 2022
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's masthead light and anchor light were inoperable. Demonstrate proper operation of navigation lights.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2022
Resolved 26 October 2022
Resolution: Vessel replaced bulbs and demonstrated operation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 October 2022
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: (1) A pressure type connector on each conductor; (2) A solder lug on each conductor; (3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. On the port side of the engine room in way of the genrerator gauge panel, cables were found improperly terminated in a lighting fixture that was missing its cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2022
Resolved 1 November 2022
Resolution: Vessel replaced light fixture cover and globe.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 October 2022
Resolved
All cable and wire must be isntalled in accordance with 46 CFR 183.340. A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of § 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. An electrical extension cord was found installed as a permanent means of supplying power to a water heater, and was found plugged in to a power strip along with cell phone chargers. Remove extension cord. If required, provide plans for the installation of a permanent means of supplying power to the installed equipment.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2022
Resolved 3 November 2022
Resolution: Vessel removed extension cord and installed new outlet.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 October 2022
Resolved
A grease extraction hood required by 46 CFR 181.400 must meet UL 710 (incorporated by reference, see 46 CFR 175.600) or other standard specified by the Commandant. (b) A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting the applicable sections of NFPA 17 or NFPA 17A (both incorporated by reference, see 46 CFR 175.600), or other standard specified by the Commandant, and must be listed by an independent laboratory recognized by the Commandant. Provide plans within 30 days to comply with galley hood and fire suppression requirements. Until resolved, VESSEL IS LIMITED TO 49 PASSENGERS in accordance with G-MSE-4 Policy letter dated 26FEB1999 titled "Grease extraction hoods on existing vessels."
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2022
Resolved 10 February 2023
Resolution: COI amended to reflect lower passenger allowance.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 January 2022
Resolved
During a fire a device must be provided to automatically
shut down power ventilation serving the protected space
and engines that draw intake air from the protected
space prior to release of the extinguishing agent into
the space. Shutdowns were working intermittently for
fixed fire extinguishing system. Have system corrected
to meet regulations and have 3 successful successive
tests of the fixed firefighting system conducted in the
presence of an attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 28 January 2022
Resolution: Vessel explained that the SeaFire control system had to be restarted after a dischrge sut down and demonstrated the function successfully.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 January 2022
Resolved
New installations of fire protection equipment on an
existing vessel, on or after March 11, 1996, must comply
with the regulations of this part. A self priming, power
driven fire pump must be installed on each vessel of not
more than 19.8 meters (65 feet) in length that carries
more than 49 passengers. On a vessel of not more than 65
feet in length carrying more than 49 passengers, the
minimum capacity of the fire pump must be 50 gallons per
minute at a pressure of not less than 60 psi at the pump
outlet. The pump outlet must be fitted with a pressure
gauge. No gauge was located at the pump outlet. Place
satisfactory gauge at pump outlet to meet regulations
and to the satisfaction of the attending Marine
Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2022
Resolved 28 January 2022
Resolution: Verified installation of a gauge and an adequate stream through the garden hose.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 January 2022
Resolved
A vessel must comply with the applicable requirements
for any radio and Electronic Position Indicating
Radiobeacon (EPIRB) installations, as set forth in 47
CFR part 80. Vessel did not have valid EPIRB
registration on-board. Provide proof of valid EPIRB
registration to attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 15 February 2022
Resolution: Through objective evidence, vessel provided proof of valid EPIRB registration.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 January 2022
Resolved
The owner, charterer, master or managing operator shall
instruct each crew member, at least once every three
months, as to the duties that the crew member is
expected to perform in an emergency including, but not
limited to, the emergency instructions listed on the
emergency instruction placard required by 46 CFR
185.510. Each EPIRB must be tested monthly using the
integrated test circuit and output indicator, to
determine that it is operative. Vessel was not able to
show more than 01 set of logged drills and EPIRB tests.
Provide last 4 logged drills and EPIRB tests to the
attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 28 January 2022
Resolution: Vessel provided completed logs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 January 2022
Resolved
Each floating waterlight must be approved in accordance
with § 161.010 in subchapter Q of 46 CFR. Waterlight
housing was cracked at battery housing. Repair/replace
waterlight to manufacturer specifications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 28 January 2022
Resolution: Vessel purchased and installed new water light.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 January 2022
Resolved
A vessel must carry either a first-aid kit approved
under approval series 160.041 or a kit with equivalent
contents and instructions. Items in kit were expired/
missing. Make kit in compliance with regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 28 January 2022
Resolution: Vessel provided new kit.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 24 June 2021
Resolved
Vessel reported once thay were back in the water that they were taking on water in lazz. Vessel starboard garboard seam needs to be dried and re-caulked. Notify MI for inspection of repair.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 July 2021
Resolution: Yard conducted repair to seam. Garboard seam has been caulked and appaers to be watertight. Vessel is to conduct sea trial for credit DD.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 May 2021
Resolved
Vessel experiencing ingress of water in lazarette in way of garboard plank and keelson, approximately two frames aft of the forward bulkhead. Diver noted missing caulking and applied splash zone to exterior as a temporary repair. Prior to carrying passengers, provide proposal for permanent repairs. Upon approval, complete repairs to the satisfaction of attending USCG marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2021
Resolution: Repairs to garboard seam complete.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 May 2021
Resolved
Port side upper plank in lazarette missing caulking. Recaulk to the satisfaction of attending USCG marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2021
Resolution: Recaulk of upper plank complete.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 May 2021
Resolved
Watertight bulkhead between lazarette and tank space leaking in way of shaft log structure. Provide repair proposal and complete repairs to the satisfaction of attending USCG marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2021
Resolution: Vessel applied epoxy to area in question. Repairs to bulkhead complete. No water ingress undeway noted.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 April 2021
Resolved
Provide a maintenance plan for galley flat top & re-route ventilation to the outside of the vessel.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 20 April 2021
Resolution: Plan provided and new exhaust fan installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 April 2021
Resolved
Provide a valid weak link for aft BA's.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 20 April 2021
Resolution: Weak link provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 April 2021
Resolved
Provide a proper mast head light and day shapes.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 20 April 2021
Resolution: Lights and day shapes provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 April 2021
Resolved
Replace light cover in salon.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 20 April 2021
Resolution: New lights installed.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 6 April 2021
Resolved
Conduct a Simplified Stability Test (SST) prior to operating with passengers.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 12 April 2021
Resolved 27 April 2021
Resolution: SST conducted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 April 2021
Resolved
Repair/Replace hertz meter on switchboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 27 April 2021
Resolution: Vessel installed new hertz meter.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 April 2021
Resolved
Provide covers for batteries.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 20 April 2021
Resolution: Covers provided.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 6 April 2021
Resolved
Prove proper operation of emergency steering.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2021
Resolution: Vessel demonstrated emergency steering.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 February 2021
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date of the COI. Vessel exceeded 3 month interval on 30SEP2020. Vessel is required to complete a satisfactory annual inspection prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2021
Resolved 27 April 2021
Resolution: All requirements of the annual inspection were met.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 5 February 2020
Resolved
The use of twist-on type wire nuts is permitted under the following condition: Connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. The light above passenger seatingarea is missing a cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2020
Resolved 18 February 2020
Resolution: Wires and twist on nuts are stowed inside a junction box.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 5 February 2020
Resolved
Each table lamp, desk lamp, floor lamp, or similar equipment must be secured in place so that it cannot be displaced by the roll or pitch of the vessel. Lighting fisture above passeger seating area is missing a cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2020
Resolved 18 February 2020
Resolution: Light was removed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 February 2020
Resolved
A vessel must carry one floating waterlight with a lanyard of 3ft and a lifeline. Life ring on bridge has inoperable waterlight and deteriorated lifeline and lanyard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2020
Resolved 18 February 2020
Resolution: New battery for light installed along with new line. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 5 February 2020
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
Guards are missing on the generator and main engine rotating belts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2020
Resolved 18 February 2020
Resolution: Vessel already had manufactured guards that were removed. They reinstalled guards. all sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 5 February 2020
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with duties.
Last fire drill was conducted and looged September 2nd, 2019.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 February 2020
Resolved 5 February 2020
Resolution: Conducted a fire drill in the galley underway with Marine Inspector onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 September 2019
Resolved
At each initial & subsequent inspection for certification & reinspection the MI shall examine & test the main & auxiliary steering apparatus to the extent necessary to determine that its condition ia satisfactory & that it is fit for the service intended. Current condition of hydraulic steering ram for single screwed vessel is extremely deteriorated & determined to be unfit for service. Vessel to renew &/or replace as indicated prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 October 2019
Resolution: Vessel renewed hydraulic ram.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 31 October 2018
Resolved
FWD BILGE ALARM VISUAL AND AUDIBLE INDICATORS WERE INOPERABLE. PROVIDE OPERABLE BILGE ALARM INDICATORS AT THE OPERATING STATION.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2018
Resolution: OPERATOR SATISFACTORILY EFFECTED REPAIRS TO FWD COMPARTMENT BILGE ALARM.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 7 November 2017
Resolved
Conduct annual servicing of fixed fire-fighting system in the presence of a Coast Guard Marine Inspector. 46CFR176.810(b)(2).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 14 November 2017
Resolution: Vessel conduct annual servicing of fixed fire-fighting system.
Lifesaving › Lifefloat › Float-free Link
Issued 7 November 2017
Resolved
Attach float-free link to vessel deck. 46CFR 180.137(c)(1).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 December 2017
Resolved 5 December 2017
Resolution: Vessel properly attached float-free link to vessel deck.
Lifesaving › Buoyant Apparatus › Marking
Issued 7 November 2017
Resolved
Make buoyant apparatus' orange in color. 46CFR180.200, 46CFR160.010
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2017
Resolved 5 December 2017
Resolution: Vessel cleaned and made the buoyant apparatus' orange in color.
Lifesaving › Buoyant Apparatus › Marking
Issued 7 November 2017
Resolved
Mark buoyant apparatus' and life float paddles with appropriate markings. 46CFR185.604(e)/(g).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2017
Resolved 5 December 2017
Resolution: Vessel properly marked the buoyant apparatus' and life float paddles with required items.
Construction/Loadline › Hull › Transverse Frame
Issued 13 September 2017
Resolved
Crop and renew areas as indicated by MI (two frames and floor frame) in forepeak.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2017
Resolved 18 September 2017
Resolution: Operator made satisfactory repairs.
Construction/Loadline › Hull › Transverse Frame
Issued 13 September 2017
Resolved
Crop and renew areas as indicated by MI (three frames) forward void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 September 2017
Resolution: Operator made satisfactory repairs.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 December 2016
Resolved
Life ring did not have ships name written on it.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2016
Resolved 20 December 2016
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 20 December 2016
Resolved
Found 13 Kapok type adult lifejackets to be unserviceable.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 December 2016
Resolved 20 December 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 December 2016
Resolved
Discovered all batteries in engine room space were installed with wing nuts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2016
Resolved 20 December 2016
Engineering › Bilge Water Management System › Piping
Issued 20 December 2016
Resolved
While trying to take suction from the fwd void vessel discovered a large hole in the bilge piping for that space.
Action required: 705 - Other - as specified
Due 20 December 2016
Resolved 20 December 2016
Stability › Watertight Integrity › General
Issued 1 February 2016
Resolved
Make hatch cover water tight for lazarette
Action required: 705 - Other - as specified
Due 3 March 2016
Resolved 4 March 2016
Resolution: O-ring in hatch renewed.
Communications › Public Address System › Loudspeaker
Issued 1 February 2016
Resolved
PA system in passenger compartment is not audible/operable. Provide proof of operating PA system.
Action required: 705 - Other - as specified
Due 3 March 2016
Resolved 4 March 2016
Resolution: PA system operational.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 February 2016
Resolved
Provide proof of updated supplies in first aid kit that meets 46CFR160.041 approval.
Action required: 705 - Other - as specified
Due 3 March 2016
Resolved 4 March 2016
Resolution: First aid kit on board