Records from 1995 to 2026. Most recent: inspection, 19 May 2026.
Inspection history · 44
19 May 2026
COI Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8375442
16 May 2025
In-Service Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8137722
28 April 2025
Internal Structural Exam · Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8121613
12 June 2024
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7933115
22 May 2023
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7693765
14 May 2023
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7709824
27 March 2023
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7657715
16 May 2022
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7451694
9 June 2021
Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7220563
18 May 2021
COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7199983
4 May 2021
Drydock Extension · Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7189190
20 August 2020
Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7037922
3 June 2019
Examination of Repairs · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6702453
24 January 2019
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6629062
22 January 2019
Damage Survey · Annual Inspection · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6613095
20 January 2019
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6637491
1 May 2018
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6402964
27 June 2017
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6188801
3 April 2017
Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6116607
19 July 2016
Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5946012
16 July 2016
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5946078
27 May 2016
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5888614
26 April 2016
Hull Examination · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5861913
10 March 2016
Type not recorded
No type recorded · Station Oak Island · USCG East District (CGD-E) · Activity 5833933
10 March 2016
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5841723
25 February 2016
Damage Survey · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5821631
20 June 2012
Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4350198
25 May 2012
DAPI Audit · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4328667
8 December 2011
Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4204482
27 July 2009
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3469866
25 June 2008
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3247519
23 June 2008
COI Inspection · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3240782
14 November 2001
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1370429
8 February 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1401402
7 January 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1446890
12 November 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1421756
8 April 1999
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 808066
9 November 1998
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1381383
9 January 1998
Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1422971
13 November 1997
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1460131
13 January 1997
Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1455430
22 December 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1189560
13 November 1995
Hull Examination · Initial Certification · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 878146
8 March 1995
Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 868792
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 May 2026
Resolved
A means to reset devices used to automatically shut down ventilation systems and engines. Manual override for pre-engineered fire system would not allow for the main engine to start. Service and show operation to the satisfaction of the MI. Prior to carrying passengers.
46 CFR 181.420(b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2026
Resolution: Verified operation
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 May 2026
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the Navigation Rules. Vessels all-around light was not functioning. Vessel is restricted to daylight operations until repaired to the satisfaction of the MI.
46 CFR 183.420
Action required: 705 - Other - as specified
Resolved 26 May 2026
Resolution: Verified operation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2026
Resolved
Fuel filters must be resistant to failure due to thermal shock. Main engine fuel filter has a small leak at seal. Repair or replace to the satisfaction of the MI.
46 CFR 182.455(b)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 26 May 2026
Resolution: Repaired
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 May 2026
Resolved
Each battery installation must be protected from falling objects. Install batteries in a proper battery box to the satisfaction of the MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 26 May 2026
Resolution: Battery boxes installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 May 2023
Resolved
Each vessel must be equipped w/ at least two operable portable battery lights; vessel is missing one light.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 22 May 2023
Resolved 22 May 2023
Resolution: Flashlight was placed onboard
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 May 2023
Resolved
A vessel must carry a first aid kit; burn gel in kit is expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 12 June 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 May 2023
Resolved
Waste receptacles must be constructed of non-combustible material w/ no openings in sides or bottom. Vessel has plastic trashcan.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 12 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2021
Resolved
Each lifering buoy must have a 60ft, buoyant, non kinking, 5/16" diameter, dark in color sythetic line attached; ring buoy lifeline is of incorrect type.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Line was replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2021
Resolved
Each ring life buoy w/ a floating waterlight must have a lanyard between 3'-6' in length; water light lanyard is deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Lanyard was replaced
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 May 2021
Resolved
Provisions shall be made by means of plugs, covers, ect. to prevent the admission of air into a space protected by fixed gas.; Closure devices are insufficient.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: New covers were procured
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 May 2021
Resolved
All vessels must have navigational lights that are in compliance w/ Inland Navigation Rules; Vessel is equipped w/ a non-compliant all around white light.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: All around light was repaired
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 August 2020
Resolved
A vessel on a Lakes, Bays, and Sounds route, and a Rivers route must carry three red hand held distress signals and three orange hand held distress signals; the vessel has only four distress signals instead of six.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 August 2020
Resolved
Each life buoy must be marked with Type II reflective material approved IAW 164.018; the reflective material is faded and no longer serviceable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 September 2020
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 20 August 2020
Resolved
The Master shall instruct each crew member as to the duties the crew member is expected to perform in an emergency and conduct drills at least once every three months; the Master has no record of drills since March 2020.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2020
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 20 August 2020
Resolved
The bilges of the vessel must be kept free of excessive accumulation of oil, trash, debris or other matters that might create a fire hazard or clog bilge system piping; The fuel tank void had several gallons of fuel in the bilge due to tank overflow.
Action required: 10 - Deficiency Rectified
Resolved 20 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 March 2019
Resolved
Propulsion machinery must be suitable for propulsion requirements. During drills the propulsion engine died. The fuel filter appears to be contaminated. Make repairs and conduct sea trials.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2019
Resolution: Received call from O/O, the filter was changed and water drained, additionally the fuel supply line was removed and cleaned out with pressurized air. The boat was then ran for 2 hours with no additional problems.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 22 March 2019
Resolved
Commercial vsl over 5 GT must have a valid COD. Current COD was destroyed when vsl sunk. Provide a copy of current COD.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
Resolution: Operator has obtained a copy of valid COD.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2019
Resolved
Commercial vsl must have EAP information posted or readily available for crew. Post or place EAP contact number in vsl folder.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
Resolution: EAP Information has been included in the vessel folder.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 March 2019
Resolved
Flares must be stored in a portable watertight container marked "DISTRESS SIGNALS". Provide container.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
Resolution: Flares have been placed in an appropriate container.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 22 March 2019
Resolved
Provide ventilation closures for port and starboard vent louvers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
Resolution: Ventilation closures have been fabricated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 March 2019
Resolved
Provide portable hand bilge pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2019
Resolution: Portable hand pump has been placed onboard.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 January 2019
Resolved
Prior to the carriage of passengers make the vessel available for a damage survey due to damage sustained when the vessel sank at the dock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2019
Resolution: All structures have been verified in satisfactory condition.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 May 2018
Resolved
Provide the following equipment to complete the requirements for the first aid kit: 12 safety pins, 10 1/2 mL iodine applicators, and 9 3" x 18" sterile petrolatum gauze.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2018
Resolution: All required items have been placed in first aid kit.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 May 2018
Resolved
Make repairs and prove proper opertion of ancor light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2018
Resolution: Nav light tested sat.
Lifesaving › Hand Flares › Quantity
Issued 4 April 2017
Resolved
Vsl has 4 in-date red hand flares and 0 orange smoke. Provide 2 additional orange smoke or red hand flares.
Due 11 April 2017
Resolved 13 April 2017
Resolution: Vessel provided new orange smoke flares (4).
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 4 April 2017
Resolved
Vsl has 1 portable light at the operating station, 2 are required. Provide second portable light at or near engine compartment.
Due 4 May 2017
Resolved 13 April 2017
Resolution: Second portable light provided at the machinery space.
Lifesaving › Lifebuoys › Serviceable
Issued 4 April 2017
Resolved
Grab line for the ring buoy is dry-rotted. Provide new ring buoy. Ensure ring buoy is properly marked/retro.
Due 4 May 2017
Resolved 13 April 2017
Resolution: Ring buoy was replaced and retro placed on it.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 April 2017
Resolved
Lifeline for the ringbuoy is dryrotted. Replace with floating 60 ft line.
Due 4 May 2017
Resolved 13 April 2017
Resolution: Lifeline properly replaced.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 April 2017
Resolved
Ammonia inhalents in first aid kit do not have expiration date. There is no petroleum burn gauze in the first aid kit. Replace both items.
Due 4 May 2017
Resolved 13 April 2017
Resolution: Both items have been replaced with in date items.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 4 April 2017
Resolved
Provide current tide table and current table for area of operation. Vsl does not have onboard.
Due 4 May 2017
Resolved 13 April 2017
Resolution: Printed excerpts of tide/currents for operating area were placed onboard.
Electrical › Electrical Distribution System (service) › Cable
Issued 4 April 2017
Resolved
Remove or properly terminate blue wire in head.
Due 4 May 2017
Resolved 13 April 2017
Resolution: Wire removed.
Engineering › Steering Gear System › Cable
Issued 19 July 2016
Resolved
Steering failure due to broken cable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 May 2016
Resolved
The operator failed to make the vessel available for inspection to renew the Certificate of Inspection; make the vessel available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2016
Lifesaving › Lifebuoys › Serviceable
Issued 27 May 2016
Resolved
Replace the ring buoy due to the deteriorated condition of the grab lines.
Due 10 June 2016
Resolved 9 June 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 May 2016
Resolved
Provide aspirin for the fist aid kit due to expiration.
Due 10 June 2016
Resolved 9 June 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 May 2016
Resolved
The stern light is inoperative, repair as necessary.
Due 10 June 2016
Resolved 9 June 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 May 2016
Resolved
The anchor light is not visible from 360 degrees due to advertisement signs, relocate the anchor light as necessary.
Due 10 June 2016
Resolved 9 June 2016
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 27 May 2016
Resolved
Provide proof of background check for the new Master, [name withheld].
Due 10 June 2016
Resolved 9 June 2016
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 27 May 2016
Resolved
Provide proof of an updated employee list due to new employees.
Due 10 June 2016
Resolved 9 June 2016
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 5 May 2016
Resolved
Install flame screen in the fuel tank vent.
Due 5 June 2016
Resolved 27 May 2016
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 February 2016
Resolved
Make repairs to the damaged handrail on the bow of the vessel, to the satisfaction of an attending USCG Marine Inspector. The bow shall be restricted to passengers until this deficiency is satisfactorily corrected.
Action required: 705 - Other - as specified
Due 25 March 2016
Resolved 11 March 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 May 2012
Resolved
Prior to operating at night provide new battery for waterlight.
Action required: 705 - Other - as specified
Due 22 June 2012
Resolved 20 June 2012
Engineering › Bilge Water Management System › Valve
Issued 25 May 2012
Resolved
Install positive shut-off valves at bilge pump hull penetrations (4).
Action required: 705 - Other - as specified
Due 22 June 2012
Resolved 25 May 2012
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 May 2012
Resolved
Properly label PFD stowage with type and qty.
Action required: 705 - Other - as specified
Due 22 June 2012
Resolved 20 June 2012
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 May 2012
Resolved
Properly display/mount COI, Stab. ltr, Emer. Procedures and donning placards.
Action required: 705 - Other - as specified
Due 22 June 2012
Resolved 20 June 2012
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 May 2012
Resolved
Repair visual indicator on fwd bilge alarm.
Action required: 705 - Other - as specified
Due 22 June 2012
Resolved 20 June 2012
Engineering › Bilge Water Management System › Not Operational
Issued 27 July 2009
Resolved
Ensure all bilge high level alarms are operational IAW 46 CFR 182.530.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2009
Resolved 29 July 2009
Resolution: Bilge high water alarm system working properly, verified by [name withheld] of [name withheld] Marina.
Construction/Loadline › Structures › Manhole
Issued 27 July 2009
Resolved
Provide captive chain and ensure engine room hatch is water tight IAW 46 CFR 179.360.
Action required: 705 - Other - as specified
Due 27 August 2009
Resolved 26 August 2009
Resolution: Vessel rep provided signed statement verifying repair work was completed.
Documentation › Certificates/Documents › FCC SSL
Issued 27 July 2009
Resolved
Provide FCC Safety and Station License IAW 47 CFR 80. Vessel restricted to 1,000 feet from shore.
Action required: 705 - Other - as specified
Due 27 August 2009
Resolved 26 August 2009
Resolution: Vessel rep provided application form verifying FCC licenses are in process.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 July 2009
Resolved
Remove all stray wires and properly mount all wires.
Action required: 705 - Other - as specified
Due 27 August 2009
Resolved 26 August 2009
Resolution: Vessel rep provided signed statement verifying repair work was completed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 June 2008
Resolved
Provide valid vessel documentation prior to any vessel operations. 46 CFR 67.7 & 67.9
Condition: Unknown
Due 15 August 2008
Resolved 27 July 2009
Resolution: COD provided
Construction/Loadline › Hull › Bottom Plating
Issued 14 November 2001
Resolved
Make repairs to hull in areas that show exposed fiberglass, several areas on bow port and starboard. Almost the entire length of the bottom of the keel. Repairs must be inspected by a Coast Guard inspector prior to going into the water.
Condition: Unknown
Due 1 January 2002
Resolved 14 July 2008
Navigation
Issued 8 February 2001
Resolved
PROVIDE NAV CHARTS OF OPERATIONAL AREA.
Condition: Unknown
Due 8 March 2001
Resolved 13 March 2001
Documentation
Issued 8 February 2001
Resolved
PROVIDE DECK LOGBOOK FOR CREW DRILLS AND EMERGENCY EQUIPMENT CHECKS.
Condition: Unknown
Due 8 March 2001
Resolved 13 March 2001
Documentation
Issued 8 February 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 March 2001
Resolved 13 March 2001
Navigation
Issued 8 February 2001
Resolved
PROVIDE TIDE AND CURRENT TABLES OF OPERATIONAL AREA.
Condition: Unknown
Due 8 March 2001
Resolved 13 March 2001
Documentation
Issued 8 February 2001
Resolved
LOG MAN-OVERBOARD DRILL.
Condition: Unknown
Due 8 March 2001
Resolved 13 March 2001
Documentation
Issued 8 February 2001
Resolved
UP-DATE CREW EMERGENCY PROCEDURES FOR MAN-OVERBOARD.
Condition: Unknown
Due 8 March 2001
Resolved 13 March 2001
Electrical
Issued 8 February 2001
Resolved
REPLACE GROUND WIRE TO PORT BATT.
Condition: Unknown
Due 8 March 2001
Resolved 13 March 2001
Construction/Loadline › Hull › Hull Plating
Issued 8 February 2001
Resolved
REPAIR JELL COAT DAMAGE TO PORT AND STBD SIDES AND TO STBD TRANSOM.
Condition: Unknown
Due 30 November 2001
Resolved 14 July 2008
Lifesaving
Issued 9 November 1998
Resolved
REPLACE BATTERIES IN FLOAT LIGHT ON RING BUOY AND PROVIDE RECEIPTS.
Condition: Unknown
Due 10 November 1998
Resolved 8 March 1999
Construction/Loadline
Issued 9 November 1998
Resolved
INSTALL BILGE ALARM IN FWD COMPARTMENT CONTAINING FUEL TANK.
Condition: Unknown
Due 19 November 1998
Resolved 8 March 1999
Lifesaving
Issued 9 November 1998
Resolved
MOUNT EMERGENCY CHECK OFF LIST IN LOCATION TO BE SEEN BY PASSENGERS AND CREW.
Condition: Unknown
Due 19 November 1998
Resolved 8 March 1999
Documentation
Issued 9 January 1998
Resolved
POST EMERGENCY (CHECKOFF) INSTRUCTIONS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 February 1998
Resolved 5 February 1998
Navigation
Issued 9 January 1998
Resolved
DEMONSTRATE PROPER OPERATION OF STERN AND ANCHOR LIGHTS, PRIOR TO OPERATINGWITH PASSENGERS.
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Engineering
Issued 9 January 1998
Resolved
MAKE PERMANENT REPAIRS AND PROPERLY INSTALL FUEL GAUGE.
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Lifesaving
Issued 9 January 1998
Resolved
PROVIDE SAFETY CHAINS OR EQUIVALENT TO SECURE BOW HANDRAIL OPENING.
Condition: Unknown
Due 1 February 1998
Resolved 5 February 1998
Lifesaving
Issued 9 January 1998
Resolved
PROVIDE EMERGENCY LIGHTING (FLASHLIGHTS), PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Lifesaving
Issued 9 January 1998
Resolved
PROVIDE AND POST LIFEJACKET DONNING INSTRUCTIONS.
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Documentation
Issued 9 January 1998
Resolved
PROVIDE PROOF OF COMPLIANCE WITH DRUG TESTING REGULATIONS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Documentation
Issued 9 January 1998
Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Lifesaving
Issued 9 January 1998
Resolved
PROVIDE 3 CG APPROVED FLARES, PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Lifesaving
Issued 13 January 1997
Resolved
PROVIDE WATERLIGHT WITH 3 TO 6 FOOT LANYARD WITH A HALYARD CLIP ATTACHED.
Condition: Unknown
Due 28 January 1997
Resolved 29 January 1997
Fire Fighting
Issued 13 January 1997
Resolved
PROVIDE 3 EACH, 2.5 GALLON FIRE BUCKETS WITH AN ATTACHED LANYARD.
Condition: Unknown
Due 28 January 1997
Resolved 29 January 1997
Lifesaving
Issued 13 January 1997
Resolved
PROVIDE REFLECTIVE TAPE ON RING BUOY.
Condition: Unknown
Due 28 January 1997
Resolved 29 January 1997