Records from 2008 to 2025. Most recent: inspection, 9 September 2025.
Inspection history · 21
9 September 2025
COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8229209
24 June 2025
Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8166567
10 June 2024
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7911671
2 February 2024
Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7861734
14 May 2023
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7709824
30 March 2023
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7659597
22 March 2023
In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7655533
29 November 2022
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7601024
23 March 2022
COI Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7416235
7 February 2022
Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7392232
4 June 2021
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7215542
15 December 2020
Hull Examination · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7111967
16 September 2020
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7059418
25 June 2020
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6986271
23 January 2020
Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6895010
21 June 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6720805
18 June 2018
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6447806
30 January 2018
Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6355231
20 March 2017
DAPI Audit · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6108164
14 July 2016
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5940168
1 March 2016
Internal Structural Exam · Drydock Exam · Hull Examination · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5829405
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 September 2025
No resolution recorded
As appropriate, for the intended voyage all vessels must carry adequate and up-to-date charts & pubs. All charts need to be updated.
Action required: 50 - Rectify deficiencies w/in 30 days
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 24 June 2025
No resolution recorded
STBD bow planks at FR4 and FR5 found rotted. Prior to haul out around October 2025, owner must submit repair plan to satisfaction of OCMI.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 June 2025
No resolution recorded
Overhead deck support FR7 in Tank space found cracked. Prior to haul out around late October 2025, owner must submit repair plan to the satisfaction of OCMI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 June 2025
No resolution recorded
Port side fuel tank inboard aft most bottom support frame found rotted in Tank space. Prior to haul out around October 2025, owner must submit repair plan to the satisfaction of OCMI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 June 2025
No resolution recorded
The bilge water levels and water intrusion in the fore-peak is excessive. This space does not have and is not required to have a bilge high level alarm or a bilge pump. A bilge high alarm must be installed in the space until repairs can be made. Prior to haul out around October 2025, owner must submit repair plan to the satisfaction of OCMI.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2025 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 June 2024
Resolved
Vessel shall install bilge high level alarms in all compartments with visual and audible alarms in the pilot house.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2024
Resolution: Deficiency cleared
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 10 June 2024
Resolved
Vessel shall ensure the fuel shut off valves are operational from outside the space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2024
Resolution: Fuel Shut off valves working properly
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 June 2024
Resolved
Vessel has an exhaust leak somewhere in it's dry exhaust
Identify/secure the source of the leak.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2024
Resolution: Exhaust leak has been fixed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 June 2024
Resolved
Demonstrate proper operation of the vessel's bilge
system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2024
Resolution: Installed electric bilge pumps tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2024
Resolved
Vessel is required 1 ring life buoy. Ensure the throw
line is at least 60' and of adequate type.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2024
Resolution: Ring buoy is properly outiffted with 60' line
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 June 2024
Resolved
Vessel's fire suppression system (pre-engineered) over-ride system is inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2024
Resolution: Witnessed satisfactory operation
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 June 2024
Resolved
Vessel's oil pressure gauge isn't working properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2024
Resolution: Deficiency cleared
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 June 2024
Resolved
Supervisory training for DAPI needs to be completed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2024
Resolution: Supervisory training is completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 10 June 2024
Resolved
All compartment hatches need to be watertight. Each of them are missing the gasket material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2024
Resolution: Tested hatch, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 April 2023
Resolved
Machinery and equipment installed on each vessel must be installed and maintained in such a manner as to afford adequate protection from causing a fire, explosion, machinery failure, and personnel injury; the main engine has an oil leak which is leaking into the cooling system as evident by the cooling water reservoir.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2023
Resolved 4 May 2023
Resolution: Oil Cooler replaced and cooling system flushed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2023
Resolved
Fuses must be of the cartridge type only and UL listed; the fuse block under the operating console is of the blade type.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 4 May 2023
Resolution: Fuse block replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 April 2023
Resolved
An adult life jacket must be provide for each person carried on board the vessel; five life jackets have been condemned due to their deteriorated condition. The vessel is restricted to the carriage of no more than 50 persons, 48 of which may be passengers, until corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 4 May 2023
Resolution: Life jackets replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 March 2022
Resolved
46 CFR 180.71- A life jacket must be provided for each person the vessel is authorized to carry as indicated on the COI; seven life jackets were condemned due to being in a deteriorated condition. The vessel is restricted to 48 total persons until rectified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 5 April 2022
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 June 2021
Resolved
Vesselâs fire plug on STBD side is
missing valve handle; install valve handle
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2021
Resolved 21 June 2021
Resolution: Vessel now has handle attached to fire station via wire to prevent tampering by pax.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 June 2021
Resolved
Spaces aft of collision bulkhead must have
bilge alarm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2021
Resolved 21 June 2021
Resolution: New bilge alarm was installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2021
Resolved
battery connections must be of terminal
type; battery charger is connected by
means of spring connectors.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2021
Resolved 21 June 2021
Resolution: Battery cahrge was removed
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 25 June 2020
Resolved
Propulsion machinery shall be suitable in design, type and condition for the hull in which it is installed without exceeding design limitations; the shaft stuffing box hose is worn and no longer serviceable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2020
Resolution: Replaced in kind.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 25 June 2020
Resolved
A vessel of at least 26 feet in length must be provided with a visual and audible alarm, at the operating station, which indicates high water level in required spaces; the bilge alarm in the forward void is not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2020
Resolution: Replaced the float switch.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 June 2020
Resolved
A vessel must carry a first aid kit, approval number 160.041, or a kit with an equivalent contents; some items in the existing kit are expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2020
Resolved 15 September 2020
Resolution: Replaced with new kit.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 June 2020
Resolved
Twist on type connectors may not be used for facilitating a conductor splice unless installed IAW 183.340 (i) (1); the float switch for the fuel tank bilge alarm is installed with twist on connectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 15 September 2020
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 June 2018
Resolved
Replace 60 ft lifeline on lifebuoy with UV resistant line.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 July 2018
Resolution: Line properly replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 18 June 2018
Resolved
Install lagging to dry exhaust on all interior bare portions.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 July 2018
Resolution: Exhaust lagging has been installed and secured.
Fire Fighting › Fire Pumps › Suction Valve
Issued 18 June 2018
Resolved
Make repairs to remote rod for fire pump suction selection valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 July 2018
Resolution: Repairs to reach rod have been made and tested.
Lifesaving › Lifebuoys › Serviceable
Issued 18 June 2018
Resolved
Make repairs to lifebuoy grabline.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 July 2018
Resolution: Permenant whipping has been applied to grab line.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 28 March 2017
Resolved
Vsl has 50 serviceable type I PFD's. Provide 05 additional adult PFD's. Passenger count limited to 48 with 2 crew.
Due 28 March 2017
Resolved 28 March 2017
Resolution: Prior to departure from second vsl inspection 5 serviceable Type I PFD were provided and labeled in the MI's presence.
Operations/Management › Drills/Instruction › Fire
Issued 28 March 2017
Resolved
Provide documentation of monthly fire extinguisher checks.
Due 28 April 2017
Resolved 15 June 2017
Resolution: Monthly fire extinguisher maintenance is now being recorded in log book.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 28 March 2017
Resolved
Provide 2nd portable light at operating station.
Due 28 April 2017
Resolved 15 June 2017
Resolution: Verified two operating portable lights onboard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 July 2016
Resolved
Provide the proper quantity of aspirin for the first aid kit.
Due 28 July 2016
Resolved 26 August 2016
Engineering › Bilge Water Management System › Pump
Issued 14 July 2016
Resolved
Provide the vessel with a hand bilge pump capable of pumping 5 GPM.
Due 28 July 2016
Resolved 26 August 2016
Engineering › Pressure Vessel › Marking and Stamping
Issued 14 July 2016
Resolved
Provide proof that the air receiver is ASME certified.
Due 14 August 2016
Resolved 15 June 2017