RIVER DRIVER

RIVER DRIVER is a 1985 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2004, most recently in June 2019, along with 25 deficiencies and 1 casualty investigation in 2011.

Records from 2004 to 2019. Most recent: inspection, 21 June 2019.

Built
1985
Last inspected
21 June 2019
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDR3116
506640
Flag
UNITED STATES
367169880, 368486460
Maury page id
psix-506640

Inspections, by type

…with no type recorded2
Years with a record 10 calendar years (2004–2019)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.2 ft × 12.0 ft × 5.2 ft
Registered tonnagegross 16 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLARD MARINE INC · ANAHEIM, CA, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBUCKSPORT, ME
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 9 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Gross Ton
13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDR3116MMSI 368486460 · active · compulsorily equipped · granted 14 July 2026, expires 14 July 2036
WDD6221MMSI 367169880 · active · voluntarily equipped · granted 14 December 2016, expires 1 March 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

NELLIE BLY Passenger (Inspected) · MISLE 43754 · 27 July 2011 · activity 4103943

Inspection history · 13

21 June 2019 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6720809
18 June 2018 Deficiency Check · Annual Inspection · ACP Periodic Oversight
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6447809
20 March 2017 DAPI Audit · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6108267
14 July 2016 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5940173
15 July 2015 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5184942
27 July 2011 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 4103943
12 July 2011 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 4078611
21 December 2009 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3654500
8 July 2009 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3528717
30 March 2009 Simplified Stability Test
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3444768
16 July 2008 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3270082
26 March 2007 COI Inspection · Simplified Stability Test
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2896225
1 June 2004 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2085203

Deficiency record · 25

Engineering › Fuel Oil Service System › Hose
Issued 18 June 2018 Resolved
Two fuel hoses on the main engine are deteriorated; replace the hoses in question.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2018
Resolved 24 July 2018
Resolution: Operator changed all four fuel hose in the area.
Engineering › Bilge Water Management System › Hose
Issued 18 June 2018 Resolved
The discharge hose on the engine compartment bilge pump is deteriorated; replace the hose in question.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2018
Resolved 24 July 2018
Resolution: The discharge hose was replaced with appropriate marine grade water hose.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 28 March 2017 Resolved
Provide second portable light at the operating station.
Due 28 April 2017
Resolved 15 June 2017
Resolution: Two portable lights tested onboard.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 28 March 2017 Resolved
Provide record of monthly portable fire extinguisher checks.
Due 28 April 2017
Resolved 15 June 2017
Resolution: Fire extinguisher maintenance is now being recorded monthly.
Lifesaving › Lifebuoys › Approval
Issued 12 July 2011 Resolved
Install reflective tape on ring buoy
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2011
Resolution: New tape installed
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 12 July 2011 Resolved
Replace expired items in first aid kit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2011
Resolved 19 July 2011
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 12 July 2011 Resolved
Provide proof of portable fire extinguishing annual servicing
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2011
Resolution: Received servicing report from [name withheld]
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 12 July 2011 Resolved
Provide proof of fixed fire extinguishing annual servicing
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2011
Resolution: Received servicing report from [name withheld]
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 12 July 2011 Resolved
Replace two broken circuit breaker switches in distribution panel
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 July 2011
Resolved 16 April 2012
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 12 July 2011 Resolved
Remove all combustible waste receptacles
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 July 2011
Resolved 16 April 2012
Engineering › Freshwater System (injector cooling) › Hose
Issued 8 July 2009 Resolved
Install two Hose Clamps on each connection for exhaust cooling hose.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 31 July 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 July 2009 Resolved
Install Lock Washers or Lock Nuts on Battery Connections.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 31 July 2009
Documentation › Certificates/Documents › Stability Letter
Issued 30 March 2009 Resolved
Vessel Stability Test results indicates that the vessel has satisfactory stability for the carriage of 33 total persons (31 passengers and 2 crew) vice 44 currently listed on Certificate Of Inspection (COI). As such the vessel's COI will be amended to reflect the new results. Till such time, the vessel is to carry no more than 31 passengers and 2 crew members.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2009
Resolved 15 April 2009
Resolution: New Stability Letter and COI issued.
Fire Fighting › Combustible Materials › Insulation
Issued 21 August 2008 Resolved
Provide proof that the subject vessel is constructed with fire retardant resin as required by 46 CFR 177.410 (b) or install USCG (164.009) approved non-combustible panels in the machinery space in accordance with 46 CFR 177.410 (c) (4).
Action required: 705 - Other - as specified
Due 7 November 2008
Resolved 30 March 2009
Resolution: Non-combustible panels were installed on the forward and aft bulkheads as well as the overhead of the engine room.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 July 2008 Resolved
Repair the anchor light.
Action required: 705 - Other - as specified
Due 16 August 2008
Resolved 21 August 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 16 July 2008 Resolved
Conduct annual servicing of the fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 August 2008
Resolved 25 July 2008
Engineering › Fuel Oil Service System › Filter
Issued 16 July 2008 Resolved
Provide flame bowls for the RACOR fuel filters.
Action required: 705 - Other - as specified
Due 16 August 2008
Resolved 21 August 2008
Engineering › Fuel Oil Service System › Filter
Issued 16 July 2008 Resolved
Provide metal petcocks or plugs for the RACOR fuel filters.
Action required: 705 - Other - as specified
Due 16 August 2008
Resolved 21 August 2008
Fire Fighting › Fire Bucket › Availability
Issued 16 July 2008 Resolved
Provide the vessel with three fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 August 2008
Resolved 25 July 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 July 2008 Resolved
Provide the vessel with a USCG (160.041) approved first aid kit the existing kit is not an approved type.
Action required: 705 - Other - as specified
Due 16 August 2008
Resolved 21 August 2008
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 16 July 2008 Resolved
Provide proof of EAP and post information as required.
Action required: 705 - Other - as specified
Due 16 August 2008
Resolved 21 August 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 26 March 2007 Resolved
Install one B-I portable fire extinguisher at operating station.
Condition: Unknown
Due 4 May 2007
Resolved 16 July 2008
Construction/Loadline › Structures › Scuttle
Issued 26 March 2007 Resolved
Attach to the hatch frame a securing device or caprtive chains to prevent its loss.
Condition: Unknown
Due 4 April 2007
Resolved 16 July 2008
Personnel › Training › First Aid/CPR
Issued 26 March 2007 Resolved
Provide proof of first aid/CPR for 50% of crew.
Condition: Unknown
Due 4 May 2007
Resolved 16 July 2008
Construction/Loadline › Structures › Door
Issued 26 March 2007 Resolved
install latching to handrail safety gates on main-deck.
Condition: Unknown
Due 4 May 2007
Resolved 16 July 2008

Casualty record · 1

27 July 2011Routine · role: Transiting Vicinity of Primary Subject · activity 4103943
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

JOHN KNOX (2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.