Records from 2005 to 2021. Most recent: inspection, 27 December 2021.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 October 2020
Resolved
A suitable metal marine type strainer shall be fitted in the fuel supply line in the engine compartment. A drip pan fitted with flame screens may be required under fuel strainers other than those mounted on the engine.
Portside Racor filter flame shield was unsecured from the filter. Require replacement to fit securely to the filter.
46CFR 182.20-40(b)(5)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2020
Resolved 9 November 2020
Resolution: Crew replaced Portside Racor filter flame shield.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 26 October 2020
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician once every five years. The FCC Communications Act Safety Radiotelephony Certificate expired 19Jun20. Require FCC-licensed technician inspection and issuance of new certificate. 47 CFR 80.903
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2020
Resolved 9 November 2020
Resolution: FCC-licensed technician performed inspection and issued valid FCC ommunications Act Safety Radiotelephony Certificate.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 26 October 2020
Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit. Operator does not have a valid operator permit. Required to obtain current operator permit.
47 CFR 80.155
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2020
Resolved 9 November 2020
Resolution: Vessel rep provided proof of a valid radio Operator Permit for Gary, a vessel operator.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 October 2020
Resolved
Junction boxes, connection boxes, and outlet boxes, for use in damp or wet locations shall be of watertight construction.
Junction box on portside engine room aft bulkhead was wasted. Require replacement or adequate repairs to ensure watertight.
46 CFR 183.10-20(k)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2020
Resolved 9 November 2020
Resolution: Crew repared the junction box on portside engine room aft bulkhead to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 October 2020
Resolved
A fire hose with a nozzle must be attached to each fore hydrant at all times.
Fire hose located midship was found to have a pinhole leak.Vessel replaced fire hose with new approved hose.
46 CFR 181.320
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 October 2020
Resolved 26 October 2020
Resolution: Vessel replaced worn hose with new approved replacement hose. Tested all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 October 2020
Resolved
A vessel must carry one floating waterlight.
Waterlight casing had a crack from top of bulb to halfway down, causing a leak when submerged in water.
Vessel replaced casing of waterlight.
46 CFR 180.70(d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 October 2020
Resolved 26 October 2020
Resolution: Vessel replaced waterlight casing.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 October 2020
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. The vessel has not completed a satisfactory annual inspection. Vessel cannot carry passengers until a satisfactory annual inspection is completed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2020
Resolved 26 October 2020
Resolution: Vessel's annual inspection was completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 March 2020
Resolved
MI noted substantial leak on port main engine raw water intake pump. Effect repairs to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2020
Resolved 12 March 2020
Resolution: Vessel effected satisfactory repairs.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 February 2020
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a dry dock examination and an internal structural at least once every two years. Vessel has not completed a satisfactory dry dock exam. Vessel must complete a satisfactory dry dock exam prior to carrying passengers.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2020
Resolved 16 June 2020
Resolution: Vessel completed satisfactory drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 September 2019
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limitations. Vessel reported loss of propulsion. Vessel required to prove proper operation of propulsion system to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2019
Resolved 24 September 2019
Resolution: Deficiency rectified to the satisfaction of the attending marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 September 2019
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to the passengers or crew. Deck rails must include a top rail with the minimum height required by this section, and lower courses or equivalent protection as required by this section. Vessels railing was damaged from collision with sailing vessel. Make proper repairs to railing on bow and starboard bow to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2019
Resolved 28 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 July 2019
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartments. Prove proper operation of installed bilge system to include the dewatering of the following spaces: forepeak, void #1, void #2, e/r & lazerette.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2019
Resolution: Vessel proved proper operation of bilge system.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 July 2019
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, & other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. at each inspection for certification and at every every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Remove all oil, water & other fire hazards from both port & stbd engine rooms & make available for inspection. ensure to properly dispose of oil or oily water, rages, etc.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 July 2019
Resolution: Vessel cleaned both engine rooms and made avaiable for inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 July 2019
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Once oil in both port & stbd engine room bilges are removed & cleaned & are free from fire hazard make vessel available for completion of required annual inspection to include underway operation & drills.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2019
Resolution: Vessel completed require annual inspection.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 8 July 2019
Resolved
The congress here by declares that it is the policy of the United States that there should be no discharges of oil or hazardous substances into or upon the navigable waters of the United States. Clean &/or renew bilge pumps, bilge piping & all other associated fittings, valves & overboard piping & equipment to prevent any discharge of oil or oily water mixtures overboard into the water.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 July 2019
Resolution: Vessel cleaned &/or renewed bilge components to prevent any discharge of oil or oily water in the water.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 July 2019
Resolved
Vessel's name missing on (04) children PFD's, vessel corrected this on the spot, deficiency entered into misle for tracking purpose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 July 2019
Resolution: cleared on the spot
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 July 2019
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartments. Prove proper operation of installed bilge system to include the dewatering of the following spaces: forepeak, void #1, void #2, e/r & lazerette. A dockside event may be conducted on 20 July 2019 for no more than 150 passengers. Vessel is restricted from carrying passengers at any other time.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 August 2019
Resolution: Cleared deficiency for the 1 time approved operation pier side.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 11 May 2018
Resolved
Replace 04 unserviceable childrens lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2018
Resolved 21 May 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 11 May 2018
Resolved
Replace wasted hydraulic hose on starboard main engine reduction gear shifting actuator w/ hose and fittings that meet SAE-J 1942 and SAE-J 1475.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2018
Resolved 15 May 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 May 2018
Resolved
Install machinery guard over rotating parts on forward end of port main engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 May 2018
Resolved 15 May 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Pressure Vessel › Marking and Stamping
Issued 8 May 2018
Resolved
Clean pressaure vessel data plate and verify size and MAWP of vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2018
Resolved 15 May 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Pressure Vessel › Relief Valve
Issued 8 May 2018
Resolved
Replace relief valve on pressure vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2018
Resolved 15 May 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 8 May 2018
Resolved
Service and/or replace empty portable fire extinguisher from galley bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2018
Resolved 15 May 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 19 January 2018
Resolved
#2 stbd side replace bolt and reseal fwd bulkhead lower seam.
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 26 January 2018
Resolution: Repaired
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 20 March 2017
Resolved
Ensure portable fire extiguishers are mounted permanently in accordance with vessel's COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 21 March 2017
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 20 March 2017
Resolved
Replace reflective tape on 19 adult and 12 child life jackets. Ensure life jackets are marked with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 21 March 2017
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 8 April 2016
Resolved
Remove overboard pumping capabilities of installed oily bilge water collection system in both port and stbd engine rooms. This does not include the required emergency bilge pumping system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 9 May 2016
Resolution: Vessel removed ovrboard discharge piping and capped off through side shell fitting.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 April 2016
Resolved
Make outboard rail height for forward stbd spiral staircase 39.5 inches high off each horizontal stair surface.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 9 May 2016
Resolution: Verified new handrails on staircase met the 39.5 in hieght requirement
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 April 2016
Resolved
Repair masthead light mast as identified.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 9 May 2016
Resolution: Masthead light repaired. It is now stationary.
Engineering › Steering Gear System › Ram Seal
Issued 8 April 2016
Resolved
Repair steering ram to eliminate hydraulic oil leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 9 May 2016
Resolution: Steering Ram repaired. The is no evidence of any leaking at the time of DFU.
Engineering › Sea-water System (primary cooling) › Piping
Issued 5 April 2016
Resolved
Replace (2) raw seawater strainers for port and starboard gensets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2016
Resolved 8 April 2016
Resolution: Raw seawater strainers replaced and connected to eliminate identified leaks.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 5 April 2016
Resolved
Replace (4) unserviceable child life jackets as ID'd.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 8 April 2016
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 5 April 2016
Resolved
Replace retroreflective tape on (4) adult life jackets as ID'd and ensure vessel name clearly displayed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 8 April 2016
Resolution: Fresh retroreflective tape placed on identified PFDs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 April 2016
Resolved
Remove all dead-end wiring in port and starboard engine rooms.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 8 April 2016
Resolution: Dead end wiring removed as specified.
Engineering › Bilge Water Management System › Valve
Issued 5 April 2016
Resolved
Provide remote actuation for bilge suction screw-down valve forward of collision bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 8 April 2016
Resolution: Bilge reach rod of sufficient length provided aboard.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 5 April 2016
Resolved
Tighten shore tie box enclosure bolts as intended by original installation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 5 April 2016
Resolution: Bolts tightened, shore tie box tightly fitted against superstructure.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 7 January 2016
Resolved
Prepare port & stbd props for inspection.
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 19 January 2016
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 January 2016
Resolved
Repair forward staircase to the satisfaction of attending MI.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 19 January 2016
Construction/Loadline › Hull › Hull Plating
Issued 7 January 2016
Resolved
Replace plank on port side as indicated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 19 January 2016
Construction/Loadline › Hull › Hull Plating
Issued 7 January 2016
Resolved
Crop and renew planking as indicated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 19 January 2016
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 January 2016
Resolved
Repair hand rail on port side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 19 January 2016
Construction/Loadline › Hull › Girder
Issued 7 January 2016
Resolved
Replace bolt in kind in potable water tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 19 January 2016
Construction/Loadline › Hull › Hull Plating
Issued 7 January 2016
Resolved
Replace bolts in kind in fuel tank compartment. (12)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 19 January 2016
Resolution: DELETED REQUIREMENT
Construction/Loadline › Hull › Hull Plating
Issued 7 January 2016
Resolved
Replace plank fastener on port side of engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 19 January 2016