Records from 1984 to 2021. Most recent: inspection, 27 December 2021.
Inspection history · 106
27 December 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7414382
17 December 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7369932
10 May 2021
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7185561
15 March 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7157353
26 October 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7084212
19 October 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7079879
3 February 2020
Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6902001
22 September 2019
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6819718
22 September 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6834851
9 July 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6743871
8 July 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6680380
8 May 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6385387
19 January 2018
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6315920
20 March 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6084324
9 May 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5873617
8 April 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5853608
5 April 2016
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5824700
7 January 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5790726
9 June 2014
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4857954
15 May 2012
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4280545
4 May 2012
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4304223
28 February 2012
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4016309
28 February 2012
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4220009
1 March 2010
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3687958
2 December 2009
DAPI Audit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3645937
1 October 2008
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3404016
26 June 2008
MTSA Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3249005
28 May 2008
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3221406
12 May 2008
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3160352
29 February 2008
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3156025
6 February 2008
Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3139161
18 July 2007
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2999678
5 June 2007
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2952639
25 April 2006
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2623080
27 February 2006
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2592780
20 October 2005
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2522071
17 August 2005
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2465906
25 May 2005
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2355088
3 May 2005
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2348390
3 February 2005
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2286268
8 January 2005
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2299532
19 August 2004
MTSA Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2163415
28 July 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2148914
8 July 2004
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2126017
17 June 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2102876
13 February 2004
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2006124
14 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1985096
19 December 2003
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1967208
10 December 2003
Construction Oversight
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1959116
30 April 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1783804
13 March 2003
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1756872
11 June 2002
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1629123
20 April 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1607932
26 April 2001
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 772317
26 April 2001
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1366638
28 February 2001
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1366673
6 August 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 48203
23 June 2000
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 818745
1 June 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1471893
27 April 2000
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1403126
9 March 2000
Deadweight Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1412060
9 February 2000
Inclining Experiment
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1417022
3 November 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1408400
2 November 1999
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 796754
4 October 1999
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1195968
1 September 1999
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1415247
16 August 1999
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 777564
30 July 1999
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1109292
15 July 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1410136
17 June 1999
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1438857
30 March 1999
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1384211
30 April 1998
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1469847
24 March 1998
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1469846
2 May 1997
Hull Examination · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1394782
12 March 1997
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 779220
2 May 1996
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1355773
26 March 1996
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1388046
4 May 1995
Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1355252
26 May 1994
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1362992
6 April 1994
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1358397
10 June 1993
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1376989
3 May 1993
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 837349
23 March 1993
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 837552
7 May 1992
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1260269
4 May 1992
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 943109
6 March 1992
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1010238
6 May 1991
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 918421
3 April 1991
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 908856
14 May 1990
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1240246
11 May 1990
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1239609
27 April 1990
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 927275
30 March 1990
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1237749
24 May 1989
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1277314
17 May 1989
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1342794
11 January 1989
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1194867
6 January 1989
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1038602
30 November 1988
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1205894
22 July 1988
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1346494
27 June 1988
Re-Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1206568
23 March 1988
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1339455
29 May 1987
Re-Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1334651
5 February 1987
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1311439
20 June 1986
COI Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 997669
26 November 1985
Credit Drydock
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1301373
26 April 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 982346
4 October 1984
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 975781
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 October 2020
Resolved
A suitable metal marine type strainer shall be fitted in the fuel supply line in the engine compartment. A drip pan fitted with flame screens may be required under fuel strainers other than those mounted on the engine.
Portside Racor filter flame shield was unsecured from the filter. Require replacement to fit securely to the filter.
46CFR 182.20-40(b)(5)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2020
Resolved 9 November 2020
Resolution: Crew replaced Portside Racor filter flame shield.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 26 October 2020
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician once every five years. The FCC Communications Act Safety Radiotelephony Certificate expired 19Jun20. Require FCC-licensed technician inspection and issuance of new certificate. 47 CFR 80.903
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2020
Resolved 9 November 2020
Resolution: FCC-licensed technician performed inspection and issued valid FCC ommunications Act Safety Radiotelephony Certificate.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 26 October 2020
Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit. Operator does not have a valid operator permit. Required to obtain current operator permit.
47 CFR 80.155
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2020
Resolved 9 November 2020
Resolution: Vessel rep provided proof of a valid radio Operator Permit for Gary, a vessel operator.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 October 2020
Resolved
Junction boxes, connection boxes, and outlet boxes, for use in damp or wet locations shall be of watertight construction.
Junction box on portside engine room aft bulkhead was wasted. Require replacement or adequate repairs to ensure watertight.
46 CFR 183.10-20(k)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2020
Resolved 9 November 2020
Resolution: Crew repared the junction box on portside engine room aft bulkhead to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 October 2020
Resolved
A fire hose with a nozzle must be attached to each fore hydrant at all times.
Fire hose located midship was found to have a pinhole leak.Vessel replaced fire hose with new approved hose.
46 CFR 181.320
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 October 2020
Resolved 26 October 2020
Resolution: Vessel replaced worn hose with new approved replacement hose. Tested all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 October 2020
Resolved
A vessel must carry one floating waterlight.
Waterlight casing had a crack from top of bulb to halfway down, causing a leak when submerged in water.
Vessel replaced casing of waterlight.
46 CFR 180.70(d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 October 2020
Resolved 26 October 2020
Resolution: Vessel replaced waterlight casing.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 October 2020
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. The vessel has not completed a satisfactory annual inspection. Vessel cannot carry passengers until a satisfactory annual inspection is completed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2020
Resolved 26 October 2020
Resolution: Vessel's annual inspection was completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 March 2020
Resolved
MI noted substantial leak on port main engine raw water intake pump. Effect repairs to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2020
Resolved 12 March 2020
Resolution: Vessel effected satisfactory repairs.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 February 2020
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a dry dock examination and an internal structural at least once every two years. Vessel has not completed a satisfactory dry dock exam. Vessel must complete a satisfactory dry dock exam prior to carrying passengers.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2020
Resolved 16 June 2020
Resolution: Vessel completed satisfactory drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 September 2019
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limitations. Vessel reported loss of propulsion. Vessel required to prove proper operation of propulsion system to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2019
Resolved 24 September 2019
Resolution: Deficiency rectified to the satisfaction of the attending marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 September 2019
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to the passengers or crew. Deck rails must include a top rail with the minimum height required by this section, and lower courses or equivalent protection as required by this section. Vessels railing was damaged from collision with sailing vessel. Make proper repairs to railing on bow and starboard bow to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2019
Resolved 28 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 July 2019
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartments. Prove proper operation of installed bilge system to include the dewatering of the following spaces: forepeak, void #1, void #2, e/r & lazerette.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2019
Resolution: Vessel proved proper operation of bilge system.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 July 2019
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, & other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. at each inspection for certification and at every every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Remove all oil, water & other fire hazards from both port & stbd engine rooms & make available for inspection. ensure to properly dispose of oil or oily water, rages, etc.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 July 2019
Resolution: Vessel cleaned both engine rooms and made avaiable for inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 July 2019
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Once oil in both port & stbd engine room bilges are removed & cleaned & are free from fire hazard make vessel available for completion of required annual inspection to include underway operation & drills.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2019
Resolution: Vessel completed require annual inspection.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 8 July 2019
Resolved
The congress here by declares that it is the policy of the United States that there should be no discharges of oil or hazardous substances into or upon the navigable waters of the United States. Clean &/or renew bilge pumps, bilge piping & all other associated fittings, valves & overboard piping & equipment to prevent any discharge of oil or oily water mixtures overboard into the water.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 July 2019
Resolution: Vessel cleaned &/or renewed bilge components to prevent any discharge of oil or oily water in the water.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 July 2019
Resolved
Vessel's name missing on (04) children PFD's, vessel corrected this on the spot, deficiency entered into misle for tracking purpose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 July 2019
Resolution: cleared on the spot
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 July 2019
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartments. Prove proper operation of installed bilge system to include the dewatering of the following spaces: forepeak, void #1, void #2, e/r & lazerette. A dockside event may be conducted on 20 July 2019 for no more than 150 passengers. Vessel is restricted from carrying passengers at any other time.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 August 2019
Resolution: Cleared deficiency for the 1 time approved operation pier side.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 11 May 2018
Resolved
Replace 04 unserviceable childrens lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2018
Resolved 21 May 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 11 May 2018
Resolved
Replace wasted hydraulic hose on starboard main engine reduction gear shifting actuator w/ hose and fittings that meet SAE-J 1942 and SAE-J 1475.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2018
Resolved 15 May 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 May 2018
Resolved
Install machinery guard over rotating parts on forward end of port main engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 May 2018
Resolved 15 May 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Pressure Vessel › Marking and Stamping
Issued 8 May 2018
Resolved
Clean pressaure vessel data plate and verify size and MAWP of vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2018
Resolved 15 May 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Pressure Vessel › Relief Valve
Issued 8 May 2018
Resolved
Replace relief valve on pressure vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2018
Resolved 15 May 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 8 May 2018
Resolved
Service and/or replace empty portable fire extinguisher from galley bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2018
Resolved 15 May 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 19 January 2018
Resolved
#2 stbd side replace bolt and reseal fwd bulkhead lower seam.
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 26 January 2018
Resolution: Repaired
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 20 March 2017
Resolved
Ensure portable fire extiguishers are mounted permanently in accordance with vessel's COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 21 March 2017
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 20 March 2017
Resolved
Replace reflective tape on 19 adult and 12 child life jackets. Ensure life jackets are marked with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 21 March 2017
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 8 April 2016
Resolved
Remove overboard pumping capabilities of installed oily bilge water collection system in both port and stbd engine rooms. This does not include the required emergency bilge pumping system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 9 May 2016
Resolution: Vessel removed ovrboard discharge piping and capped off through side shell fitting.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 April 2016
Resolved
Make outboard rail height for forward stbd spiral staircase 39.5 inches high off each horizontal stair surface.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 9 May 2016
Resolution: Verified new handrails on staircase met the 39.5 in hieght requirement
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 April 2016
Resolved
Repair masthead light mast as identified.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 9 May 2016
Resolution: Masthead light repaired. It is now stationary.
Engineering › Steering Gear System › Ram Seal
Issued 8 April 2016
Resolved
Repair steering ram to eliminate hydraulic oil leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 9 May 2016
Resolution: Steering Ram repaired. The is no evidence of any leaking at the time of DFU.
Engineering › Sea-water System (primary cooling) › Piping
Issued 5 April 2016
Resolved
Replace (2) raw seawater strainers for port and starboard gensets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2016
Resolved 8 April 2016
Resolution: Raw seawater strainers replaced and connected to eliminate identified leaks.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 5 April 2016
Resolved
Replace (4) unserviceable child life jackets as ID'd.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 8 April 2016
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 5 April 2016
Resolved
Replace retroreflective tape on (4) adult life jackets as ID'd and ensure vessel name clearly displayed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 8 April 2016
Resolution: Fresh retroreflective tape placed on identified PFDs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 April 2016
Resolved
Remove all dead-end wiring in port and starboard engine rooms.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 8 April 2016
Resolution: Dead end wiring removed as specified.
Engineering › Bilge Water Management System › Valve
Issued 5 April 2016
Resolved
Provide remote actuation for bilge suction screw-down valve forward of collision bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 8 April 2016
Resolution: Bilge reach rod of sufficient length provided aboard.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 5 April 2016
Resolved
Tighten shore tie box enclosure bolts as intended by original installation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 5 April 2016
Resolution: Bolts tightened, shore tie box tightly fitted against superstructure.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 7 January 2016
Resolved
Prepare port & stbd props for inspection.
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 19 January 2016
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 January 2016
Resolved
Repair forward staircase to the satisfaction of attending MI.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 19 January 2016
Construction/Loadline › Hull › Hull Plating
Issued 7 January 2016
Resolved
Replace plank on port side as indicated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 19 January 2016
Construction/Loadline › Hull › Hull Plating
Issued 7 January 2016
Resolved
Crop and renew planking as indicated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 19 January 2016
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 January 2016
Resolved
Repair hand rail on port side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 19 January 2016
Construction/Loadline › Hull › Girder
Issued 7 January 2016
Resolved
Replace bolt in kind in potable water tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 19 January 2016
Construction/Loadline › Hull › Hull Plating
Issued 7 January 2016
Resolved
Replace bolts in kind in fuel tank compartment. (12)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 19 January 2016
Resolution: DELETED REQUIREMENT
Construction/Loadline › Hull › Hull Plating
Issued 7 January 2016
Resolved
Replace plank fastener on port side of engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 19 January 2016
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 9 June 2014
Resolved
Relabel lifejacket stowage areas for adults and children.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 30 June 2014
Resolution: Adult and childrens lfejacket stowage areas relabeled.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 9 June 2014
Resolved
Replace reflective tape on lifejackets as I.D.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 30 June 2014
Resolution: Reflective tape replaced on previusly ID''d lifejackets.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 9 June 2014
Resolved
Relabel electrical panel in engine room.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 30 June 2014
Resolution: Engine room electrical panel correctly relabeled.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 9 June 2014
Resolved
Label missing circuits on electrical panel in galley
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 30 June 2014
Resolution: All circuits correctly labeled on galley electrical panel.
Engineering › Lubricating Oil Service System › Hose
Issued 15 May 2012
Resolved
Replace as needed, with approved materials & fittings, non-metallic hoses in way of main engine starboard side.
Action required: 705 - Other - as specified
Due 30 May 2012
Resolved 27 January 2014
Resolution: Found that hoses were replaced in satisfactory condition during the hull exam.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 February 2012
Resolved
Install machinery guards on both #1 and #2 Main engines.
Action required: 705 - Other - as specified
Due 8 April 2012
Resolved 30 April 2012
Resolution: Machinery guards were installed over the shafts for the port and starboard main engine.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 October 2008
Resolved
As per the owners request (Ltr dated 01OCT2008 scanned in documents), vessel is restricted to no more than 150 passengers for the route specified on the Certificate of Inspection (COI).
Due 28 February 2009
Resolved 23 June 2010
Resolution: Received an e-mail message dated 23Jun2010 following a signed letter dated 01Oct2008 confirming vessel is permanently reducing its passenger count to 150 passengers and inspected under Subchapter T.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 12 May 2008
Resolved
Provide fixed firefighting report for range guard prior to operating galley equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2008
Resolved 15 May 2008
Resolution: Provided fixed firefighting report.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 12 May 2008
Resolved
Provide a seeal/cap or direct vent opening of the MSD tank to the outside of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2008
Resolved 28 May 2008
Resolution: Vent opening capped off.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 12 May 2008
Resolved
Repair sewage leak from forward toilet piping in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2008
Resolved 28 May 2008
Resolution: Sewage leak repaired.
Construction/Loadline › Structures › Ventilators
Issued 28 June 2007
Resolved
Provide supply and exhaust vents for each machinery space meeting the requirements in 46 CFR 182.465.
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 13 July 2007
Resolution: Ventilation ducts added to both engine rooms.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 28 June 2007
Resolved
Provide single line electrical drawing for pre-engineered fixed fire fighting system, submit to Sector LA-LB
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 11 July 2007
Resolution: Drawings provided.
Electrical › Electrical Distribution System (emergency) › Fuse
Issued 28 June 2007
Resolved
Provide circuit protection for power sources in the fixed fire fighting system, in accordance with 46 CFR 183.
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 13 July 2007
Resolution: Circuit protection provided.
Engineering › Bilge Water Management System › Pump
Issued 5 June 2007
Resolved
Provide metallic installed bilge pump in accordance with 46 CFR 119.520. Current pump has a plastic pump housing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2007
Resolved 28 June 2007
Fire Fighting › Fire Pumps › Arrangement
Issued 5 June 2007
Resolved
Provide metallic installed fire pump meeting the requirements of 46 CFR 118.300. Current pump is plastic and only approved for pool and spa use.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2007
Resolved 28 June 2007
Construction/Loadline › Hull › Side Shell
Issued 5 June 2007
Resolved
Clean rot behind air compressor in stbd engine room and treat.
Action required: 705 - Other - as specified
Due 25 July 2007
Resolved 28 June 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 June 2007
Resolved
Provide fixed fire fighting extinguishing service report.
Action required: 705 - Other - as specified
Due 25 July 2007
Resolved 28 June 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 June 2007
Resolved
Provide ring buoy light for upper deck ring buoys. Current light is cracked and sinks. Vessel may not operate after one hour before sunset to one hour after sunrise, until cleared to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 25 July 2007
Resolved 28 June 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 25 April 2006
Resolved
Provide approved fire extinguishing system in engine room & servicing report IAW 46 CFR 118.400. The vessel may operate with passengers using a CCTV system installed in both port & starboard engine rooms monitored by a designated senior deckhand with communications to the Master, at all times while passengers are on board . The existing fixed CO2 system must be serviced and ready for operation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 May 2006
Resolved 10 May 2006
Resolution: Approved fixed fire extinguishing system installed in port and starboard engine rooms.
Operations/Management › Drills/Instruction › Not Conducted
Issued 25 April 2006
Resolved
Conduct underway drills I.A.W. 46 CFR 122.520 & 122.524.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2006
Resolved 28 April 2006
Resolution: Conducted satisfactory underway drills.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 25 April 2006
Resolved
Provide hydrostatic test of vessels air pressure tank.
Action required: 705 - Other - as specified
Due 28 May 2006
Resolved 18 July 2006
Resolution: Owner installed an approved new air pressure tank.
Engineering › Bilge Water Management System › Piping
Issued 28 February 2006
Resolved
Replace 02 bilge suction lines from manifold; 1.5 inch galvanized steel wasted.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 3 March 2006
Resolution: New bilge lines installed.
Engineering › Gasoline Engine (propulsion) › Exhaust Port (4 cycle)
Issued 28 February 2006
Resolved
Repair and remount port exhaust and double clamp STBd side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 19 April 2006
Resolution: Port exhaust remounted and double clamped.
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 February 2006
Resolved
Corrosion build-up on STBD raw water line in E/R. Conduct general maintenance.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 19 April 2006
Resolution: Proper maintenance conducted.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 28 February 2006
Resolved
Provide mettalic spacers throughout E/R; not more than 24 inch spacing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 19 April 2006
Resolution: Mettalic spacers properly installed in E/R.
Engineering › Diesel Engine (auxiliary) › Bedplate
Issued 28 February 2006
Resolved
Repair portside MDE motor mount; base rotted.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 19 April 2006
Resolution: Motor mount repaired.
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 28 February 2006
Resolved
Repair loose fastners portside E/R.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 19 April 2006
Resolution: All mettallic fastners tightened.
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 February 2006
Resolved
Close off open pipe in sea chest.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 19 April 2006
Resolution: Open pipe closed off.
Construction/Loadline › Hull › Keel Plate
Issued 28 February 2006
Resolved
Treat rot in portside keel in lazarette.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 19 April 2006
Resolution: Wood rot treated satisfactorily.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 27 February 2006
Resolved
Replace bilge screen monitor portside lazarette
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 19 April 2006
Resolution: New bilge screen installed.
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 27 February 2006
Resolved
Repair F/O leak in Port MDE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 19 April 2006
Resolution: F/O leak secured.
Construction/Loadline › Structures › Superstructure
Issued 27 February 2006
Resolved
Repair 4x4 staircase stanchion wood support; wood rotted.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 19 April 2006
Resolution: New stanchion support installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 February 2006
Resolved
Provide light fixture covers for flourescent lights in galley.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 19 April 2006
Resolution: Light fixtures installed.
Electrical › Lighting (service) › Outlet Box
Issued 27 February 2006
Resolved
Secure junction boxes in overhead - galley.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 19 April 2006
Resolution: Junction box secured.
Construction/Loadline › Structures › Superstructure
Issued 27 February 2006
Resolved
Repair portside rails forward; base rotted.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 19 April 2006
Resolution: Base repaired and secured.
Construction/Loadline › Structures › Superstructure
Issued 27 February 2006
Resolved
Repair portside aft stanchion; base block rotted.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 19 April 2006
Resolution: Base block repaired.
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 February 2006
Resolved
Conduct appropriate checkride.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 3 March 2006
Resolution: Conducted checkride.
Fire Fighting › Ventilation Systems › Ducts
Issued 25 May 2005
Resolved
Provide adequate ventilation closure for engine room prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2005
Resolved 26 May 2005
Resolution: Repaired ventilation closure and is now operating properly.
Fire Fighting › Remote Fuel Shutoff › General
Issued 25 May 2005
Resolved
Repair/Replace starboard fuel shut-off valve so that it is working properly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2005
Resolved 26 May 2005
Resolution: Repaired starboard fuel shut-off valve.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 May 2005
Resolved
Provide explosion proof covers for three light fixtures in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2005
Resolved 17 August 2005
Resolution: Provided explosion proof light covers.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 May 2005
Resolved
Ensure all wiring is secured with metal clamps every 24" throughout vessel.
Action required: 705 - Other - as specified
Due 27 June 2005
Resolved 17 August 2005
Resolution: Provided metal clamps every 24" throughout vessel.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 25 May 2005
Resolved
Provide Fire Control Plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2005
Resolved 17 August 2005
Resolution: Provided Fire Control Plan.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 25 May 2005
Resolved
Provide emergency evacuation plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2005
Resolved 17 August 2005
Resolution: Provided emergency evacuation plan.
Construction/Loadline › Structures › Machinery Space Opening
Issued 25 May 2005
Resolved
Plug open fitting on port side engine room.
Action required: 705 - Other - as specified
Due 27 June 2005
Resolved 17 August 2005
Resolution: Plugged open fitting on port side of engine room.
Engineering › Fuel Oil Service System › Gauge
Issued 25 May 2005
Resolved
Provide adequate fuel tank sounding device.
Action required: 705 - Other - as specified
Due 27 June 2005
Resolved 17 August 2005
Resolution: Provided fuel tank sounding device.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 25 May 2005
Resolved
Provide radio operator's certificate.
Action required: 705 - Other - as specified
Due 27 June 2005
Resolved 23 June 2005
Resolution: Provided raio operator''s certificate.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 May 2005
Resolved
Repair/Replace detiorated electrical lights forward of rescue platform.
Action required: 705 - Other - as specified
Due 27 June 2005
Resolved 17 August 2005
Resolution: Repaired detioriated electrical lights.
Lifesaving › Lifejacket/PFD (Type II)
Issued 19 December 2003
Resolved
VESSEL REMOVED LIFEJACKETS
Due 30 December 2003
Resolved 22 December 2003
Resolution: ALL LIFEJACKETS RESTORED BACK ON VESSEL.
Lifesaving › Lifejacket/PFD (Type I)
Issued 8 May 2003
Resolved
Provide 32 adult PFD's. Passenger count limited to 234 adults and 32 children. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2003
Resolved 20 May 2003
Resolution: [name withheld] informed me that he witnessed a receipt for 32 PFD''''s on 5/19/2003. See notes in narrative.
Documentation › Safety/Response Plans/Programs
Issued 8 May 2003
Resolved
Provide Fire control plan IAW 116.530. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 June 2003
Resolved 9 March 2004
Operations/Management › Vessel Safety Management
Issued 8 May 2003
Resolved
Provide emergency evacuation plan IAW 116.520. LEGACY COMPONENT DESC: Emergency Preparedness
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 June 2003
Resolved 9 March 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 6 May 2003
Resolved
Label engineroom CO2 pull handle LEGACY COMPONENT DESC: Operating Controls
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2003
Resolved 8 May 2003
Resolution: labeled sufficiently
Fire Fighting › Remote Fuel Shutoff
Issued 6 May 2003
Resolved
Repair Emergency fuel shut-off valve pulley system. Port valve does not fully close.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2003
Resolution: System repaired and functuonal.
Fire Fighting › Grease Extraction Hood
Issued 6 May 2003
Resolved
Provide service/maintenance report. LEGACY COMPONENT DESC: Installed Range Guard
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2003
Resolved 8 May 2003
Resolution: Provided servicing invoice. See additional notes in narrative.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 6 May 2003
Resolved
Provide replacement for unusable/molded/outdated light list.
Condition: Improper/Lack of Maintenance
Due 8 June 2003
Resolved 8 May 2003
Resolution: provided.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 May 2003
Resolved
Provide electrical housekeeping under the bridge helm. Area is very dirty with trash, oily residue from multiple leaks (addressed elsewhere in this activity), and needs general re-organization of the wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 8 May 2003
Resolution: Area cleaned up, re-organized, and (apparently) leaks repaired. Although a rough addition of amperage draw from the recepticle/circuit under the helm showed within respectable limit, master Jason was advised of too many devices powered from this circuit
Engineering › Steering Gear System
Issued 6 May 2003
Resolved
Repair leak on helm steering pump and clean oily residue. The leak is spilling down onto many wiring bundles under the helm. LEGACY COMPONENT DESC: Hand Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 8 May 2003
Resolution: Leak appears to be repaired.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 6 May 2003
Resolved
Repair oil leak at helm main engine oil pressure gauge and clean oily residue. The leak is spilling down onto many wiring bundles under the helm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 8 May 2003
Resolution: leak appears to be repaired.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 6 May 2003
Resolved
Replace retro on 13 Adult life jackets. Replace retro and clean/lubricate snaps on 7 Child life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 8 May 2003
Resolution: All life jackets repaired.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 6 May 2003
Resolved
Provide portable lighting at entrance to enginerooms.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 8 May 2003
Resolution: Flashlight installed.
Engineering › Gasoline Engine (auxiliary) › Exhaust Piping (4 cycle)
Issued 6 May 2003
Resolved
Properly secure STBD generator exhaust/water lift.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 8 May 2003
Resolution: lift bolted down properly.
Engineering › Fuel Oil Service System › Piping
Issued 6 May 2003
Resolved
Provide 2 hoseclamps on STBD generator fuel supply hose.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 8 May 2003
Resolution: Repaired
Engineering › Generator (propulsion-electric)
Issued 6 May 2003
Resolved
Provide new hose on STBD generator valve cover exhaust. LEGACY COMPONENT DESC: Crankcase ventilator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 8 May 2003
Resolution: New hose installed.
Construction/Loadline › Hull
Issued 6 May 2003
Resolved
Repair and re-attach bonding wire to main r/w suction valve. LEGACY COMPONENT DESC: Bonding system
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 8 May 2003
Resolution: Bonding strap attached.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 6 May 2003
Resolved
Provide double hose clamp on PORT m/e r/w suction. LEGACY COMPONENT DESC: Raw water cooling
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 8 May 2003
Resolution: Repaired.
Engineering › Fuel Oil Service System › Pump
Issued 6 May 2003
Resolved
Repair fuel leak at main f/o priming pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 8 May 2003
Resolution: Repaired.
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 6 May 2003
Resolved
Provide cover for STBD generator batteries.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 8 May 2003
Resolution: Cover installed.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 6 May 2003
Resolved
Renew PORT generator r/w suction hose and clamps. LEGACY COMPONENT DESC: R/W cooling
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 8 May 2003
Resolution: Hose and clamps replaced.
Electrical › Electric Generation Source (service) › Switch
Issued 6 May 2003
Resolved
Replace starting battery parallel (knife) switch.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 8 May 2003
Resolution: Switch replaced.
Stability › Watertight Integrity
Issued 13 March 2003
Resolved
Completely remove water from bilges and make vessel available for check ride NLT 04APR03. LEGACY COMPONENT DESC: leaking seams
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2003
Resolved 4 April 2003
Resolution: Conducted check ride, discovered seems in lazarette where repairs and re-caulking were attempted, was leaking and seeping water into space. Vessel was allowed to sail via permission from OCMI.
Accommodation/Occupational Safety
Issued 13 March 2003
Resolved
Insects noted in #2 cmpartment port side. LEGACY COMPONENT DESC: Insects in voids and other spaces below deck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2003
Resolved 4 April 2003
Resolution: Owner contracted Acurid Comercial Services to identify insects and control infestation. Insect were identified as Lice (Psocids) from seagulls. See hard copy for contract.
Construction/Loadline
Issued 13 March 2003
Resolved
Remove bottom paint to bare wood and side paint to 1ft above chine during next drydocking. *This was not conducted due to time constraints for this drydock. It appears necessary to remove all the old paint in order to properly apply a new sound coat. Painting over old paint not acceptable. LEGACY COMPONENT DESC: bottom and side paint
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 9 March 2004
Resolution: Advised Carl/Randy this requirement was lifted, Randy opted to sandblast anyway and apply
Construction/Loadline › Structures
Issued 13 March 2003
Resolved
Renew underdeck brackets on bow overhang. Discovered non marine grade hardware to support and secure the bow overhang. LEGACY COMPONENT DESC: Underdeck bracket on bow
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 April 2003
Resolved 4 April 2003
Resolution: replaced with new non marine grade hardware to support and secure the bow overhang.
Construction/Loadline › Hull
Issued 13 March 2003
Resolved
Make permanent repairs to insert on stbd side 11 plank from stern. Discovered an old throughhull carriage style bolt that wasted away and caused galvanic corrosion to the surrounding wood resulting in an 1 inch hole. item temporaly repaired with a 4inch plug/insert. till next drydock. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2004
Resolved 25 March 2004
Resolution: Lead patch installed on waterside, butt block installed on dryside.
Construction/Loadline › Hull › Bottom Plating
Issued 13 March 2003
Resolved
Provide repair proposal for areas of damaged wood around metal through bolts in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2003
Resolved 4 April 2003
Resolution: Provided repair proposal.
Stability
Issued 13 March 2003
Resolved
re-mount foam in lazarette. Foam used for stability purposes only was removed for drydock exam access purpose only. LEGACY COMPONENT DESC: foam in lazarette
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 April 2003
Resolved 4 April 2003
Resolution: replaced foam.
Stability
Issued 13 March 2003
Resolved
Ensure bilges are kept debris free. LEGACY COMPONENT DESC: bilges/spaces
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2003
Resolved 4 April 2003
Resolution: bilges appeared debris free during check.
Lifesaving › Lifejacket/PFD (Type I)
Issued 11 June 2002
Resolved
Renew 16 adult lifejackets. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Due 18 June 2002
Resolved 16 October 2002
Construction/Loadline › Penetrations
Issued 11 June 2002
Resolved
Pipe penetrations between engineroom and lazerette need to be sealed and abandon pipe penetration stbd side engineroom
must be removed and sealed to ensure engineroom is gas tight.
Condition: Unknown
Due 11 July 2002
Resolved 11 June 2002
Navigation
Issued 28 February 2001
Resolved
Repair (blast to near-white metal & grind thin edges) and coat rudders and reweld exposed seams on aft end of rudders.
Condition: Unknown
Due 26 November 2001
Resolved 26 November 2001
Construction/Loadline
Issued 28 February 2001
Resolved
Replace "L" brackets on port skeg.
Condition: Unknown
Due 26 November 2001
Resolved 26 November 2001
Unknown
Issued 28 February 2001
Resolved
Conduct a corrosion survey with a qualified marine surveyor or qualified individual.
Condition: Unknown
Due 26 November 2001
Resolved 26 November 2001
Construction/Loadline
Issued 3 November 1999
Resolved
Provide visual indicators at the operating station that indicate when any automatic bilge pump is operating. Any installed automatic bilge pump may not be energized until an indicator system is installed. This item must becorrected to the satisfaction of an attending marine inspector.
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Lifesaving
Issued 17 June 1999
Resolved
Renew five Adult Life Jackets. Totals persons reduced to 194 until item is cleared.
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Fire Fighting
Issued 17 June 1999
Resolved
Renew Guage on Fire Man System. Test System for proper operation. IAW 46CFR118.300
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Lifesaving
Issued 17 June 1999
Resolved
Resecure Hand Rails on after stairs, forward stairs and forward main deck rail. All rails appeared to be loose.
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Electrical
Issued 17 June 1999
Resolved
Lable Engine Room Circuit Breakers. IAW 46CFR123.380
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Lifesaving
Issued 17 June 1999
Resolved
First Aid Kit needs to updated IAW 46CFR 121.710
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Fire Fighting
Issued 17 June 1999
Resolved
Remove non-ferrous piping in fire main system, replace with Ferrous piping IAW 46CFR56.60, 46CFR118.310 & 46CFR119 part G.
Condition: Unknown
Due 1 July 1999
Resolved 30 June 1999
Engineering
Issued 17 June 1999
Resolved
Make repairs to fuel oil shut off valve, which allows supply valve on tank to closed 100% via remote shut down cable IAW 46CFR119.455
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Lifesaving
Issued 17 June 1999
Resolved
Install Flooding Alarms IAW 46CFR119.530
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Electrical
Issued 17 June 1999
Resolved
Repair water pump on ship service generator, pump is leaking excessive water.
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Lifesaving
Issued 2 May 1997
Resolved
Provide proper first aid kit. Complete no later than 9 May 97._x001C_
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Deck/Cargo
Issued 2 May 1997
Resolved
Renew anchor line. Complete no later than 9 May 97 and before operating with passengers._x001C_
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Fire Fighting
Issued 2 May 1997
Resolved
Repair heat detector in STB engine room. Complete no later than 5 May 97
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Fire Fighting
Issued 2 May 1997
Resolved
Make the following repair to the engine room fixed system (CO2): a. Install shut downs for main engines & generators that shut off all engines upon discharge of CO2. b. Post operating instructions for system. Complete no later than 2 Jul 97._x001C_
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Electrical
Issued 3 May 1993
Resolved
PROVIDE METAL CABLE SUPPORTS FOR WIRING IN THE ENGINEROOM AND ELECTRICAL ROOM, EVERY TWO FEET AS SPECIFIED IN IEEE STANDARD 45, SECTION 20.5.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Navigation
Issued 3 May 1993
Resolved
PROVE OPERATION OF ANCHOR LIGHT.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Accommodation/Occupational Safety
Issued 4 May 1992
Resolved
PROVIDE WRITTEN WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 8 May 1992
Resolved 8 May 1992
Construction/Loadline
Issued 4 May 1992
Resolved
PROVIDE PROPER LABELING TO ALL BILGE MANIFOLD VALVES.
Condition: Unknown
Due 8 May 1992
Resolved 8 May 1992
Navigation
Issued 11 May 1990
Resolved
PROVIDE A BLACK BALL DAY SHAPE.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Fire Fighting
Issued 11 May 1990
Resolved
PROVIDE AN ELECTRIC FIRE PUMP WITH SUFFICIENT CAPACITY TO PROVIDE A SATISFACTORY WATER PRESSURE FOR THE FIRE MAIN STATION ON THE SECOND DECK.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Documentation
Issued 11 May 1990
Resolved
PROVIDE A CURRENT VESSEL DOCUMENT.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Unknown
Issued 11 May 1990
Resolved
DISPLAY PAGES OF THE CERTIFICATE OF INSPECTION SEPARATELY UNDER GLASS OR OTHER SUITABLE TRANSPARENT MATERIAL IN A CONSPICUOUS LOCATION.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Unknown
Issued 11 May 1990
Resolved
DISPLAY THE VESSEL'S STABILITY LETTER UNDER GLASS OR SUITABLE TRANSPARENT MATERIAL IN A CONSPICUOUS LOCATION.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Construction/Loadline
Issued 30 March 1990
Resolved
MAKE BULKHEAD BETWEEN THE ENGINEROOM AND STEERING GEAR COMPARTMENT WATER- TIGHT BY PLUGGING HOLES SIZES RANGE FROM 2" TO 12" WITH A MATERIAL EQUIVA- LENT TO THE BULKHEAD.
Condition: Unknown
Due 30 March 1990
Resolved 30 March 1990
Navigation
Issued 17 May 1989
Resolved
PROVIDE 6 RED AND 6 ORANGE HAND HELD FLARES.
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Fire Fighting
Issued 17 May 1989
Resolved
INSTALL A PRESSURE GAUGE ON THE DISCHARGE LINE OF THE FIRE PUMP.
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Engineering
Issued 17 May 1989
Resolved
INSTALL PROTECTIVE COVER FOR THE ROTATING DRIVESHAFT COUPLING OF THE PORT AND STARBOARD MAIN PROPULSION ENGINES.
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Navigation
Issued 17 May 1989
Resolved
SECURE LOOSE BOLT AND NUT CONNECTING MANUAL HYDRAULIC ROD TO MAIN STEERINGSYSTEM.
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Electrical
Issued 6 January 1989
Resolved
REPAIR ELECTRICAL WIRING SPLICES ON 110V/12V STEP DOWN TRANSFORMER FOR LOW POWER LIGHTS WITH METAL CRIMP CONNECTORS OR SOLDERED PERMANENTLY.
Condition: Unknown
Due 6 January 1989
Resolved 6 January 1989
Engineering
Issued 6 January 1989
Resolved
REPAIR BROKEN BILGE PICK-UP TUBE AND STRAINER IN STARBOARD SIDE SEWAGE HOLDING TANK COMPARTMENT.
Condition: Unknown
Due 6 January 1989
Resolved 6 January 1989
Engineering
Issued 6 January 1989
Resolved
CLEAN OIL OUT IN THE ENGINEROOM BILGES.
Condition: Unknown
Due 6 January 1989
Resolved 6 January 1989
Navigation
Issued 27 June 1988
Resolved
PROVIDE CURRENT SUBCHAPTER "T".
Condition: Unknown
Due 27 June 1988
Resolved 27 June 1988
Fire Fighting
Issued 27 June 1988
Resolved
LABEL PORTABLE FIRE EXTINGUISHER BOXES AS TO CONTENTS.
Condition: Unknown
Due 27 June 1988
Resolved 27 June 1988
Lifesaving
Issued 27 June 1988
Resolved
PROVIDE LIFE PRESERVER DONNING INFORMATION PLACARD.
Condition: Unknown
Due 27 June 1988
Resolved 27 June 1988
Lifesaving
Issued 27 June 1988
Resolved
PROVIDE FOUR ADULT AND ONE CHILD LIFE PRESERVER.
Condition: Unknown
Due 27 June 1988
Resolved 27 June 1988
Fire Fighting
Issued 27 June 1988
Resolved
PROVIDE TWO CG APPROVED FIRE HOSES.
Condition: Unknown
Due 27 June 1988
Resolved 27 June 1988
Engineering
Issued 29 May 1987
Resolved
PROVE LIFTING PRESSURE,SEATING PRESSURE OF RELIEF VALVE ON AIR TANK.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Fire Fighting
Issued 29 May 1987
Resolved
SERVICE ALL PORTABLE AND FIXED FIRE EXTINGUISHERS.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Lifesaving
Issued 29 May 1987
Resolved
PROVIDE 6 CG APPROVED ADULT PFD.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987