Records from 2008 to 2025. Most recent: inspection, 6 May 2025.
Inspection history · 22
6 May 2025
MTSA Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8129824
4 February 2025
In-Service Inspection · Drydock Exam · Plan Review (Other than "T") · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8077234
25 July 2024
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7967003
16 January 2024
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7849707
7 July 2023
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7738624
21 March 2023
Internal Structural Exam · Administrative Inspection · Drydock Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7650929
14 February 2023
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7636650
16 January 2023
Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7630618
9 June 2022
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7471220
30 March 2021
MTSA/ISPS Verification · Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7165875
1 February 2021
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7141846
16 September 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7059114
6 August 2020
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7026488
16 June 2020
Internal Structural Exam · In-Service Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6984336
30 April 2019
Periodic Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6672853
10 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6536758
12 June 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6442184
13 February 2018
Administrative Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6355355
26 April 2017
Deficiency Check · Examination of Repairs · Annual Inspection · Damage Survey · Plan Review (Other than "T") · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6134203
6 June 2016
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5899492
25 April 2016
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5862188
6 January 2016
Hull Examination · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5804371
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2025
Resolved
At each inspection for certification and periodic inspection the marine inspector must conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as they feel necessary to check safe operation.
During annual COI inspection the STBD Drive Unit tripped off-line multiple times.
Prior to the Carriage of Scientific Personnel prove proper operation of the STBD propulsion system to the satisfaction of the attending CG Marine Inspector.
Vessel is permitted to transit directly to home port in St. Petersburg, FL to conduct repairs and inspections.
Action required: 705 - Other - as specified
Resolved 19 May 2025
Resolution: A new deficiency was issued by SEC St Petersburg.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2025
No resolution recorded
Test procedure documents must be in a step-by-step or checkoff list format. Each test instruction must specify equipment status, apparatus necessary to perform the tests, safety precautions, safety control and alarm setpoints, the procedure to be followed, and the expected test result.
The approved PSTP does not provide procedures to be followed and simulates testing. Submit updated PSTP to MSC for approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025 — due date passed with no resolution recorded
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 6 May 2025
Resolved
Each separator must be designed in accordance with the applicable requirements in subchapters F and J of this chapter.
The Oily Water Separator is not permanently connected to the electrical system. The system is temporarily plugged into the outlet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 20 May 2025
Resolution: OWS was wired into a juction box and was opeational. System not used and was lock and tagged out.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 May 2025
Resolved
Existing structure arrangements and materials previously approved will be considered satisfactory so long as they are maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection. Minor repairs and alterations may be made to the same standards as the original construction.
Structural Fire Protection insulation is missing IWO the 308 generator on STBD side. Replace missing SFP.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 20 May 2025
Resolution: Florida Marine Joinery installed SFP over the genset space.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 6 May 2025
Resolved
Each blank must conform to the design requirements of 104.5.3 of ASME B31.1 (incorporated by reference; see § 56.01-2).
The ball valves on port and starboard side were found with out a blank installed and is open to the inboard side of the ship. Install blanks on ball valves where piping is not connected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 20 May 2025
Resolution: P/S ball valves were blanked off and locked out.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 6 May 2025
Resolved
At each inspection for certification and periodic inspection, the inspector shall examine the vessel to determine that it meets the vessel design and equipment requirements for pollution prevention in 33 CFR part 155, subpart B.
The Watertight door #7 on STBD side has a hydraulic leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 2 June 2025
Resolution: Crew replaced hydraulic rams.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 July 2024
Resolved
Means shall be provided for closing all other openings to the space protected from ouside the space.
Marine Inspector identified port and stbd ventilation closures not sealing properly.
7/30/24: Temporary seals have been installed.
46 CFR 193.15-35(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 12 January 2025
Resolution: Received email with photos of the fire dampeners being fixed. All fire dampener doors had latches added to the top. This removed the gap between the doors and fixture - all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 July 2024
Resolved
Piping subject to internal head pressure from oil in the tank must be fitted with positive shutoff vlaves located at the tank.
Marine Inspector identified emergency f/o shut-off valves at the day tank not closing properly.
46 CFR 56.50-60(d)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2024
Resolution: Valve operates SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 July 2024
Resolved
Each hull of a vessel with more than one hull must have at least two means for pumping the bilges in each hull. No multi-hulled vessel may operate unless one of these means is available to pump each bilge.
Marine Inspector identified port hull bilge pump is not operational due to piping failure.
46 CFR 56.50-55(e)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2024
Resolution: Pump operates SAT.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 July 2024
Resolved
Fire detecting, manual alarm, and supervised patrol systems are not required, but if installed, the systems shall meet the applicable requirements of part 76 of Subchapter H (Passenger Vessels) of this chapter.
Marine Inspector identified fire detection panel had not been serviced. Identified trouble alarm on the panel. **Required 7 days to find a company that can service panel.**
7/30/24: Service company scheduled to attend the vessel on 12AUG24.
46 CFR 193.05-1
Action required: 705 - Other - as specified
Due 12 August 2024
Resolved 14 August 2024
Resolution: Fire detection system tested and serviced SAT.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 July 2024
Resolved
Fire detecting, manual alarm, and supervised patrol systems are not required, but if installed, the systems shall meet the applicable requirements of part 76 of Subchapter H (Passenger Vessels) of this chapter.
Heat detectors above both 3408 generators found inoperative.
46 CFR 193.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2024
Resolved 14 August 2024
Resolution: Both detectors replaced and tested SAT by servicing company.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 July 2024
Resolved
The CSO or VSO must ensure an audit of the VSP is performed annually, beginning no later than one year from the initial date of approval and attache a letter ot the VSP certifying that the VSP meets the applicable requirements of this part.
Vessel had not conducted and annual audit for VSP.
33 CFR 104.415(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2024
Resolved 14 August 2024
Resolution: Audit completed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 July 2024
Resolved
Vessel security exercises must be conducted at least once each calendar year, with no more than 18 months between exercises.
No documentation provided for the last completed security exercise.
33 CFR 104.230(c)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2024
Resolved 21 April 2025
Resolution: Chief Mate e-mailed supporting documentation reflecting a security exercise was completed on 08JAN2025. Def Cleared.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 July 2024
Resolved
Each section of firehose must bge lined commercial firehose that conforms to Underwriters Laboratories, Inc. Standard 19 or Federal Specification ZZ-H-451E. Hose that bears the label of Underwriters Laboratories, Inc. as lined firehose is accepted as conforming to this requirement.
Marine Inspector identified a pihhole leak in one section of 50' fire hose. Hose replaced in kind and tested satisfactorily.
46 CFR 95.10-10(n)
Action required: 10 - Deficiency Rectified
Resolved 29 July 2024
Resolution: Hose replaced in kind and tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 July 2024
Resolved
Fire detecting, manual alarm, and supervised patrol systems are not required, but if installed, the systems shall meet the applicable requirements of part 76 of Subchapter H (Passenger Vessels) of this chapter.
Marine Inspector identified one smoke detector inoperative. Detector replaced in kind and tested satisfactorily.
46 CFR 193.05-1
Action required: 10 - Deficiency Rectified
Resolved 29 July 2024
Resolution: Detector replaced in kind and tested satisfactorily.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 July 2024
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date, except as specified in § 189.27-5. The anniversary date on the vessel's COI is 07 February 2023, vessel is overdue for its annual inspection.
46 CFR 189.27-1(a)
17C
Action required: 17 - Rectify deficiencies prior to departure
Due 25 July 2024
Resolved 29 July 2024
Resolution: Completed annual inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 May 2023
Resolved
Identified wooden plug approximately 2" in diameter in Space 4 Frame 10-12 transducer space top of compartment next to access. Provide plan proposal for repair.
Action required: 705 - Other - as specified
Due 30 June 2023
Resolved 10 July 2023
Resolution: Review plns which show the pipe is a drain pipe from the upper space to the lower. C/E installed a mechanical plug to seal off the pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 6 August 2020
Resolved
(a)All automatically or remotely controlled or monitored vital systems addressed by part 62 of this subchapter must be subjected to tests and inspections to evaluate the operation and reliability of controls, alarms, safety features, and interlocks. Test procedures must be submitted to the Coast Guard for approval.
(b) Persons designated by the owner of the vessel shall conduct all tests and the Design Verification and Periodic Safety tests shall be witnessed by the Coast Guard.
(c) Design Verification and Periodic Safety test procedure documents approved by the Coast Guard must be retained aboard the vessel.
Provide copies of of approved and completed DVTPs and PSTPs to Coast Guard Sector San Francisco.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 September 2020
Resolution: Approval letter received and uploaded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 6 August 2020
Resolved
Tests must be conducted at periodic intervals specified by the Coast Guard to confirm that vital systems and safety features continue to operate in a safe, reliable manner. Complete approved PSTP in it's entirety by end of the calendar year and provide completed copy to Coast Guard Sector San Francisco.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2020
Resolved 2 December 2020
Resolution: Received copy of completed PSTP from PE
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018
Resolved
NAME: Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 30 April 2019
Resolution: Vessel updated AIS information.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 3 November 2017
Resolved
Make permanent repairs to leaking port forward fuel tank which has been taken out of service until repairs can be made prior to credit drydock March 2018.
Action required: 705 - Other - as specified
Due 24 March 2018
Resolved 27 March 2018
Resolution: Repair completed.
Construction/Loadline › Penetrations › Pipe Flange
Issued 3 November 2017
Resolved
Make port shaft tube available for internal inspection, crop and renew if necessary with the same repair completed on the stbd side prior to credit drydock March 2018.
Action required: 705 - Other - as specified
Due 24 March 2018
Resolved 27 March 2018
Resolution: Repair completed.
Engineering › Bilge Water Management System › Piping
Issued 26 April 2017
Resolved
Submit repair proposal to crop and renew corroded sections of port/stbd aluminum ballast/bilge piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2018
Resolved 2 November 2017
Resolution: Repairs completed and tested.
Construction/Loadline › Penetrations › Pipe Flange
Issued 26 April 2017
Resolved
Submit repair proposal for corroded section of stbd stern tube and make repairs prior to carrying scientific personnel.
Action required: 705 - Other - as specified
Resolved 2 November 2017
Resolution: Repairs completed and tested.