Construction/Loadline › Hull › Bottom Plating
Issued 28 April 2017
Resolved
Hole found in port battery box and hull plating below. Vessel to replace battery box and crop and renew bottom plating prior to completion of credit dry dock.
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 5 May 2017
Resolution: Vessel completed insert and replaced battery box.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 April 2017
Resolved
Lifejackets found with deteriorated floatation. Show adequate numbers of lifejackets that are serviceable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2017
Resolved 3 May 2017
Resolution: Vessel identified and replaced deteriorating PFDs.
Fire Fighting › Fire Pumps › Power Source
Issued 18 April 2017
Resolved
Show proper operation of fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2017
Resolved 18 April 2017
Resolution: Corrected on the spot.
Lifesaving › Lifefloat › Serviceable
Issued 18 April 2017
No resolution recorded
Repair or replace damaged lifefloats. Until repaired, vessel is not permitted to carry passengers beyond 3 NM from shore.
Action required: 705 - Other - as specified
Due 18 April 2017 — due date passed with no resolution recorded
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 18 April 2017
Resolved
Provide calibrated and current alcohol testing device.
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 3 May 2017
Resolution: Provided.
Communications › Radio Communications › VHF Radiotelephone
Issued 18 April 2017
Resolved
Provide FCC Safety Radiotelephony, Bridge to Bridge, and EPIRB registration certificates with current call sign and MMSI number.
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 3 May 2017
Resolution: Provided and updated in MISLE.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 18 April 2017
Resolved
Provide current tide and current tables.
Action required: 705 - Other - as specified
Due 2 May 2017
Resolved 28 April 2017
Resolution: Vessel provided current publications.
Engineering › Steering Gear System › Linkage
Issued 18 April 2017
Resolved
Replace starboard rudder tiller cross link pin prior to drydock completion/credit.
Action required: 705 - Other - as specified
Resolved 3 May 2017
Resolution: Vessel provided new pin.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 April 2017
Resolved
Replace missing engine room lighting globe cages.
Action required: 705 - Other - as specified
Due 2 May 2017
Resolved 5 May 2017
Resolution: Vessel replaced lighting globes.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 April 2017
Resolved
Repair or replace port main diesel engine raw water piping inboard prior to drydock completion/credit.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 3 May 2017
Resolution: Vessel replaced raw water piping.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 18 April 2017
Resolved
Provide exhaust lagging on starboard engine room exhaust prior to drydock completion/credit.
Action required: 705 - Other - as specified
Resolved 3 May 2017
Resolution: Vessel provided new lagging.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 18 April 2017
Resolved
Provide structural fire protection on port fuel tank prior to drydock completion/credit.
Action required: 705 - Other - as specified
Resolved 28 April 2017
Resolution: SFP provided.
Construction/Loadline › Structures › Superstructure
Issued 18 April 2017
Resolved
Repair cracks in bulkhead/gunwhale and railing in way of port side forward embarkation area prior to drydock completion/credit.
Action required: 705 - Other - as specified
Resolved 28 April 2017
Resolution: Cracks welded.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 30 March 2017
Resolved
Replace fallen insulation in steering compartment.
Action required: 705 - Other - as specified
Resolved 28 April 2017
Resolution: SFP replaced.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 30 March 2017
Resolved
Provide insulation on underside of engine access hatches in steering compartment.
Action required: 705 - Other - as specified
Resolved 28 April 2017
Resolution: SFP integrated into engine hatches.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 30 March 2017
Resolved
Replace or clean carbon-covered insulation in steering compartment.
Action required: 705 - Other - as specified
Resolved 3 May 2017
Resolution: SFP replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 March 2017
Resolved
Provide machinery guard at aft end of port generator.
Action required: 705 - Other - as specified
Resolved 28 April 2017
Resolution: Guard replaced.
Construction/Loadline › Penetrations › Gasket
Issued 30 March 2017
Resolved
Replace hatch gaskets as necessary and ensure readiness for chalk-testing.
Action required: 705 - Other - as specified
Resolved 3 May 2017
Resolution: Gasket repaired.
Engineering › Bilge Water Management System › Piping
Issued 30 March 2017
Resolved
Show integrity of bilge piping on starboard pipe at the aft bulkhead penetration of the fuel tank compartment.
Action required: 705 - Other - as specified
Resolved 28 April 2017
Resolution: Bilge piping disasembled. Nipple was slightly wasted but serviceable.
Construction/Loadline › Hull › Transverse Frame
Issued 30 March 2017
Resolved
Provide repair proposal for cracks in way of aft frame on port side of compartment 2.
Action required: 705 - Other - as specified
Resolved 28 April 2017
Resolution: Welded satisfactorily.
Construction/Loadline › Hull › Stiffener
Issued 30 March 2017
Resolved
Provide repair proposal for crack in deck stiffener on fwd stbd compartment 2.
Action required: 705 - Other - as specified
Resolved 1 May 2017
Resolution: Vessel properly repaired crack.
Construction/Loadline › Hull › Side Shell
Issued 30 March 2017
Resolved
Provide repair proposal for crack in fillet weld in way of forepeak connection of transverse swash bulkhead to hull on starboard side.
Action required: 705 - Other - as specified
Resolved 1 May 2017
Resolution: Vessel properly repaired crack.
Electrical › Electric Supply System (service) › Cable
Issued 15 March 2016
Resolved
Battery cable chaffed with worn insulation and exposed hot wiring in aft engine room. Replace as original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Resolution: Inslatted new cable.
Engineering › Sea-water System (primary cooling) › Valve
Issued 15 March 2016
Resolved
Prove operation of frozen cooling water valve serviceing port generator in aft engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Electrical › Electrical Distribution System (service) › Cable
Issued 15 March 2016
Resolved
Provide support brackets for power cable to port side generator in aft engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 15 March 2016
Resolved
Make repairs to holed exhaust piping starboard side aft engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Stability › Watertight Integrity › General
Issued 15 March 2016
Resolved
Crop and renew wasted and holed watertight hatch to aft engine room under ladder to upper deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Resolution: Operator installed new hatch.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 March 2016
Resolved
Aft engine room bilge pump wiring is spliced using a wire nut, replace with but-connector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 March 2016
Resolved
Install cap on exposed battery cell, starboard side aft engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Electrical › Electrical Distribution System (service) › Panelboard
Issued 15 March 2016
Resolved
Make repairs to wasted electrical distribution panel in forward engine room and label all breakers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Electrical › Electric Supply System (service) › Battery Conductor
Issued 15 March 2016
Resolved
Replace chaffed battery cable starboard side forward engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Construction/Loadline › Penetrations › Pipe Flange
Issued 15 March 2016
Resolved
Remove flex hose outboard of valves throughout forward engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 15 March 2016
Resolved
Provide indicator to mark sewage tank at 3/4 level.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Engineering › Bilge Water Management System › Piping
Issued 15 March 2016
Resolved
Repair holes in bilge piping, forward engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Fire Fighting › Fire Main › Condition
Issued 15 March 2016
Resolved
Repaire hole in fire main piping, starboard side, forward engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Engineering › Bilge Water Management System › Piping
Issued 15 March 2016
Resolved
Crop and renew wasted bilge pipe in fuel tank compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016