B. NO. 235

Built
1995
Last inspected
5 March 2025
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 5 March 2025
…with no type recorded36
Operational controls None recorded without a removal date
Years with a record 28 calendar years (1995–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8646850
WCY3730
422969
Flag
UNITED STATES
Maury page id
psix-422969

Documentation record

Registered dimensions (L × B × D)461.8 ft × 80.0 ft × 36.2 ft
Registered tonnagegross 8,498 / net 8,498
ITC dimensions (L × B × D)461.8 ft × 80.0 ft × 36.2 ft
ITC tonnagegross 10,845 / net 6,249
BuilderGRETNA MACHINE&IRON WORKS · HARVEY, LA, UNITED STATES · built 1995
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un, reg
DocumentationExpired · issued 30 June 2004
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8498 - Regulatory (Subpart C or D), Gross Ton
10845 - Convention (Subpart B), Gross Ton
8498 - Regulatory (Subpart C or D), Net Ton
6249 - Convention (Subpart B), Net Ton
20589 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 109 inspections, each with its date, unit and type; 126 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

WILLIAM F FALLON JR Towing Vessel · MISLE 429662 · 8 November 2017 · activity 6359151WILLIAM F FALLON JR Towing Vessel · MISLE 429662 · 26 December 2007 · activity 3123506WILLIAM F FALLON JR Towing Vessel · MISLE 429662 · 4 March 2005 · activity 2305035M/V TURQUOISE COAST Towing Vessel · MISLE 370701 · 8 January 2001 · activity 46996M/V TURQUOISE COAST Towing Vessel · MISLE 370701 · 15 December 2000 · activity 26942

Inspection history · 109

5 March 2025 Deficiency Check · Administrative Inspection
Physical examination · USCG East District (dp) · USCG East District (CGD-E) · Activity 8088596
16 September 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7313409
30 June 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7240872
15 May 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6953655
21 May 2019 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6689410
1 May 2019 Damage Survey · In-Service Inspection · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6680552
29 March 2019 Damage Survey · Permit to Proceed · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6652275
29 March 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6653879
23 July 2018 Examination of Repairs · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6488363
9 July 2018 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6473564
22 June 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6452673
18 June 2018 MTSA Verification · MARPOL Annex I Examination · MARPOL Annex II Examination · Periodic Inspection · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6407891
3 April 2018 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6384492
11 January 2018 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6336774
8 November 2017 Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6303943
8 November 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6359151
15 August 2017 In-Service Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6241852
1 June 2017 MTSA Verification · Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6156361
10 June 2016 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5903475
1 June 2016 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5894286
3 February 2015 COI Inspection · Hull Examination · Examination of Repairs · Deficiency Check · Administrative Inspection · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5063053
16 October 2014 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5008774
17 July 2014 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4931711
17 June 2014 MARPOL Annex I Examination · MTSA Verification · Periodic Inspection · MARPOL Annex VI Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4891473
4 October 2013 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4729057
13 September 2013 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4728661
25 June 2012 MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4357056
19 April 2012 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4289386
7 March 2012 Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4295261
17 February 2012 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4246627
20 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4211446
25 November 2011 Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4194646
20 January 2010 Administrative Inspection · MARPOL Annex I Examination · Internal Structural Exam · Drydock Exam · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3666705
13 July 2009 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3537522
1 July 2009 Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3518288
30 July 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3283901
9 July 2008 MARPOL Annex V Examination · MTSA Verification · Drydock Exam · Annual Inspection · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3262839
3 July 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3269584
26 December 2007 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3123506
14 August 2007 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3027685
11 July 2007 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2991464
20 June 2007 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2966932
12 March 2007 Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2886343
11 August 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2743872
26 June 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2692439
10 May 2006 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2645627
12 April 2006 COI Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2621377
15 March 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2603052
3 February 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2578888
1 December 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2544906
6 June 2005 Hull Examination · Internal Structural Exam · Cargo Tank Internal · Annual Inspection · MTSA Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2381855
14 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2309853
11 March 2005 Deficiency Check · Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2308279
4 March 2005 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2305035
29 January 2005 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2282856
17 November 2004 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2246995
24 September 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2209990
24 September 2004 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2210014
30 August 2004 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2178379
28 August 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2209200
15 July 2004 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2125134
28 May 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2080677
5 May 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2059645
5 March 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2021234
9 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1962416
10 September 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1901839
2 September 2003 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1894341
12 August 2003 Periodic Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1874960
12 August 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1877193
11 January 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1728910
7 December 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1715765
1 July 2002 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1639699
5 June 2002 Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1625999
29 November 2001 Internal Structural Exam · Examination of Repairs · Hull Examination · Damage Survey
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1433892
2 May 2001 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1384754
18 April 2001 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464369
21 February 2001 Examination of Repairs · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1057969
16 February 2001 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1058306
9 January 2001 Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1056525
8 January 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 46996
15 December 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 26942
10 October 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 283004
7 June 2000 Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1464957
2 February 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 34293
17 November 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 434859
5 October 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 514092
28 June 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1079645
21 June 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 881523
26 April 1999 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1449168
27 May 1998 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1446652
10 February 1998 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 775535
20 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 525280
12 January 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 509779
3 October 1997 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1121788
21 September 1997 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 539402
8 July 1997 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1375094
1 May 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1371786
14 February 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1110133
6 November 1996 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1170499
29 July 1996 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1457372
4 March 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 715357
26 February 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 53933
26 February 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 222307
13 November 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 875777
22 October 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 443391
18 October 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 882874
23 September 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 439707
1 June 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 451297
25 May 1995 Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1363306

Deficiency record · 126

02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 1 May 2019 Resolved
No extensive alterations involving the safety of a tank vessel either in regard to the hull or machinery shall be made without the approval of the CG. Conduct gauging of the main deck of the barge and submit the gauging report to the CG for review. [name withheld] know on a daily basis the progress of the gauging. Action - Prior to reinspection for COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency. Refer to MISLE activities
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 May 2019 Resolved
If during an internal structural structural examination, cargo tank internal examination, or underwater survey, damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the OCMI may require the vessel to be taken out of service to further assess the extent of the damage. Properly set up staging along the transverse and centerline bulkheads of all cargo tanks and make available for inspection to a CG marine inspector. Action - Prior to reinspection for COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency. Refer to MISLE activities
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 May 2019 Resolved
No extensive alterations involving the safety of a tank vessel either in regard to the hull or machinery shall be made without the approval of the CG. Properly de-scale the framing and structural members underneath all deck and machinery houses in order for the CG marine inspectors to properly inspect. Action - Prior to reinspection for COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency. Refer to MISLE activities
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 May 2019 Resolved
Vessels that operate in salt water must be inspected in accordance with the intervals set forth in table 31.10-21(a). Properly deballst and remove mud for CG marine inspectors to inspect all ballast tanks for credit ISE. Action - Prior to reinspection for COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency. Refer to MISLE activities
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 1 May 2019 Resolved
No extensive alterations involving the safety of a tank vessel either in regard to the hull or machinery shall be made without the approval of the CG. Submit a repair proposal plan, clean, and gas free ballast tank 1P due to the cargo migration found. CG will then review the repair proposal and discuss with the company representative. While repairs are being conducted, CG marine inspectors shall be present for any fit-up, back gouge, final weld inspection and NDT, prior to any coating/oaint covering the repair. Action - Prior to reinspection for COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 1 May 2019 Resolved
No extensive alterations involving the safety of a tank vessel either in regard to the hull or machinery shall be made without the approval of the CG. Submit plans pertaining to the prior alterations of the cargo tank expansion trunks including approval received, proposed palns, and final testing conducted. Action - Prior to reinspection for COI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 2 April 2019 Resolved
Gas-free all cargo tanks, voids, and rakes and setup staging at the cargo tank tops to conduct examination of additional wastage. All rust beneath deck houses must be de-scaled to allow for visual examination.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 2 April 2019 Resolved
Gas-free all cargo tanks, voids, and rakes and setup staging at the cargo tank tops to conduct examination of additional wastage. All rust beneath deck houses must be de-scaled to allow for visual examination.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency.
02 - Structural Conditions › N/A - No Subsystem › Spaces in cargo areas
Issued 29 March 2019 Resolved
Hole found on the main deck under the accommodation house located on the outboard side 4 angles back from the forward end. The hole is located above the #8 starboard cargo tank and is approximately 1 inch in diameter. Cargo spilled out of the hole and entered the water. Area must be repaired and proven satisfactory to an attending CG Marine Inspector
Action required: 30 - Ship detained
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency.
02 - Structural Conditions › N/A - No Subsystem › Spaces in cargo areas
Issued 29 March 2019 Resolved
Soft patch discovered on the main deck located above the #8 port cargo tank. Soft patch was covering a hole approximately 3/4" in diameter. Area must be repaired and proven satisfactory to an attending CG Marine Inspector.
Action required: 30 - Ship detained
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 March 2019 Resolved
Electrical junction box found below the accommodation house was damaged and exposed to cargo vapors. Must repair prior to movement.
Action required: 30 - Ship detained
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 29 March 2019 Resolved
Repair sight glasses for the #1 port and #5 starboard cargo tanks. Request for supplies for sight glasses were previously submitted to the company via SMS deficiency report but no follow up received.
Action required: 30 - Ship detained
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 29 March 2019 Resolved
Crane motor winches were leaking oil on deck and was previously reported to the company via SMS deficiency report. No follow up conducted by the company in accordance with their approved SMS procedures.
Action required: 30 - Ship detained
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 29 March 2019 Resolved
The Captain's relieving report forms were not signed by the vessel supervisor and returned to the barge captain in accordance with company's approved SMS procedures.
Action required: 30 - Ship detained
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 March 2019 Resolved
Electrical junction box found in the wire channels had a wire attached to it. Crew was unable to determine if it was a dead end or live wire. Wire must be removed or secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 29 March 2019 Resolved
Cargo tank overfill alarms for #8 port and starboard and #1 port did not audibly sound.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency.
02 - Structural Conditions › N/A - No Subsystem › Spaces in cargo areas
Issued 29 March 2019 Resolved
Cargo tank ullages did not seat properly. Ensure all gaskets are in working order and prove to the satisfaction of an attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 29 March 2019 Resolved
SMS External audit must be completed by appropriate RO prior to clearing of detention
Action required: 30 - Ship detained
Resolved 5 March 2025
Resolution: Subject vessel has been determined to have been scrapped with 18 outstanding deficiencies. Deficiency cleared as part of MISLE data base clean up. Deficiency marked as resolved but no action was taken to rectify this deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 9 July 2018 Resolved
A Coast Guard Marine Inspector must be present for the connection of hoses to the manifold, and the start of the discharge of the current product, due to the incident that took place on 06 July 2018.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 11 July 2018
Resolution: Coast Guard team witnessed rigging & pre-discharge practices and proceeded to witness early stages of cargo discharge.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 11 January 2018 Resolved
Indicating lights were out on 120V and 480V systems, supply was not available to test the 240V system. Provide adequate ground detection for 480V, 240V, and 120V systems.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2018
Resolution: Ground detection lights were energized and tested.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 January 2018 Resolved
Inspectors had difficulty verifying electrical distribution system due to poor labeling. Provide missing nameplate on switchboard and labels on breaker panels IAW with approved drawings.
Action required: 705 - Other - as specified
Due 11 February 2018
Resolved 21 February 2018
Resolution: New labels were placed on switchboard, 240V distribution panel, and 240/120 transformer.
Electrical › Electrical Distribution System (service) › Cable
Issued 11 January 2018 Resolved
Various cables between alarms and sensors for cargo tank overfill protection had metal sheathing completely deteriorated. The sheath was also not properly terminated at the connector where the cable enters enclosure. Replace non-continuous armored cable as per IEEE Std 45.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 3 April 2018
Resolution: Sheathing replaced and satisfactory.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2018 Resolved
Masthead lights are within hazardous zone when mast is in the down position. Lights on mast are not proper rating to be in hazardous zone.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 18 June 2018
Resolution: Attending Marine Inspector witnessed the power being interupted when the mast is placed in the downward position.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 11 January 2018 Resolved
Gaskets on cargo tank guaging tubes are deteriorated and need replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2018
Resolution: Cargo gauging tube gaskets were replaced.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 15 August 2017 Resolved
2 Pin hole leaks in Vapor Control Piping. Conducted repairs (clad welding) without notifying Coast Guard or having any Coast Guard oversight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2017
Resolved 16 August 2017
Resolution: Vessel conducted proper repairs of deficiencies to the satisfaction of attending CG inspector.
Lifesaving › Rigid Liferafts › Hydrostatic Release Unit
Issued 1 June 2017 Resolved
Marine Inspector noted life raft painter was not attached to the weak link of the vessel. In addition, hydrostatic release was installed upside down.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2017
Resolved 1 June 2017
Resolution: Marine Inspector witnessed [name withheld] correct deficiency. Deficiency corrected on spot.
Lifesaving › Rocket Parachute Flares › General
Issued 1 June 2017 Resolved
Marine Inspector noted emergency flares had expired in April 2017. Prior to departure from port, dispose of expired flares and replace in-kind.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2017
Resolved 1 June 2017
Resolution: Marine Inspector was still conducting inspection when 12 emergency flares were delivered to vessel. Deficiency corrected on spot.
Lifesaving › Launching Appliances › Release Mechanism
Issued 1 June 2017 Resolved
Marine Inspector noted hydrostatic release (HRU) for EPIRB had expired in March 2017. Prior to departure from port, dispose of expired HRU and replace in-kind.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2017
Resolved 1 June 2017
Resolution: Marine Inspector was still conducting inspection when new HRU was delivered to vessel, witnessed [name withheld] install correctly. Deficiency corrected on spot.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 1 June 2017 Resolved
No. 4 starboard cargo tank high level/overfill alarm was not operational. Prior to loading cargo into No. 4 starboard cargo tank, provide tech report attesting to proper operation of high level/overfill alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2017
Resolution: Received tech report from [name withheld] attesting to correction and proper operation of high level/overfill alarm for No. 4 starboard cargo tank.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 1 June 2017 Resolved
Marine Inspector noted bracket for CO2 cylinder attached to paint locker was wasted.
Condition: Improper/Lack of Maintenance
Due 14 June 2017
Resolved 1 June 2017
Resolution: Vessel had spare bracket on board, Marine Inspector witnessed [name withheld] change bracket out. Deficiency correct on spot.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 1 June 2017 Resolved
Marine Inspector noted thermo-coupling devices had been installed in the hazardous zone to read temperature of asphalt when carried as cargo. Vessel could not provide documentation that temperature sensing equipment was intrinsically safe. Prior to using temperature sensing equipment in hazardous zone, provide documentation that equipment is intrinsically safe.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 2 June 2017
Resolution: Received manufacturer specifications that temperature sensing equipment was intrinsically safe.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 1 June 2016 Resolved
Overspeed cutout failed to actuate and shutdown the #2 SSDG
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 10 June 2016
Resolution: Rcvd Technical report, repair has been accepted.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 1 June 2016 Resolved
The #1 SSDG has a excessive exhaust leak.
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 10 June 2016
Resolution: Rcvd Technical report, repair report accepted
Deck/Cargo › Cargo Heating › General
Issued 3 February 2015 Resolved
Thermal Fluid Heater Circulation pump inoperable.
Action required: 705 - Other - as specified
Resolved 20 March 2015
Resolution: Owner replaced electronic control unit for circ pump.
Accommodation/Occupational Safety › Heating › Piping
Issued 3 February 2015 Resolved
Generators were missing lagging.
Action required: 705 - Other - as specified
Resolved 20 March 2015
Resolution: Owner replaced lagging on both generators.
Fire Fighting › Structural - Horizontal Zones › General
Issued 3 February 2015 Resolved
Loose wires with exposed end in hazardous location.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2015
Resolution: Owner replaced loose wire in a juction box.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 3 February 2015 Resolved
PV valves were not installed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2015
Resolution: Owner installed all PV valves.
Electrical › Lighting (service) › Lighting Fixture
Issued 3 February 2015 Resolved
Deck light had loose and exposed wires and was inopeable.
Action required: 705 - Other - as specified
Resolved 20 March 2015
Resolution: Owner properly installed deck light.
Engineering › Generator (propulsion/auxiliary-electric) › Overcurrent Devices Circuitry
Issued 18 June 2014 Resolved
Each generator prime mover must have an overspeed device independent of normal operating governor as well as shut down automatically upon loss of lubricating pressure, proper operation of both must be conducted in the presence of attending coast guard marine inspector.
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 17 July 2014
Documentation › Logs/Records › Oil Record Book
Issued 25 June 2012 Resolved
Improper entry. Follow instructions on proper entry into the Oil Record Book.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2012
Resolved 26 June 2012
Resolution: Tankerman instructed other crewmembers in proper log entries.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 June 2012 Resolved
Provide proper mounting for electrical junction box on stbd aft side cargo pump engine room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2012
Resolved 26 June 2012
Resolution: Junction box was properly remounted to bulkhead.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 25 June 2012 Resolved
Install adequate lagging on cargo pump room exhaust.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2012
Resolved 26 June 2012
Resolution: Lagging on exhaust was repaired satisfactorily.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 25 June 2012 Resolved
Properly paint and mark all vapor lines.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2012
Resolved 26 June 2012
Resolution: All vapor lines properly marked.
Deck/Cargo › Cargo Heating › General
Issued 25 June 2012 Resolved
Replace gaskets and repairs wasted coamings on vent closure on top of heater room prior to cargo ops.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2012
Resolved 26 June 2012
Resolution: All vents were found to be in satisfactory condition.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 25 June 2012 Resolved
Repair/replace closures to paint lockers adjacent to berthing and cargo pump engine room.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2012
Resolved 26 June 2012
Resolution: One paint locker and its contents were removed from the vessel completely and the other repaired to close properly.
Pollution Prevention/Response › Prevention Equipment › Emergency Control Systems (tank barges)
Issued 25 June 2012 Resolved
Replace broken emergency shutdown pull cable on cargo pump engine.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2012
Resolved 26 June 2012
Resolution: Pull cable completely replaced and tested. Cargo pump engine shutdown IAW regulations.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 25 June 2012 Resolved
Repair and prove propper operation of all high level and overfill alarms prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2012
Resolution: All high level and overfill alarms were tested and were found satisfactory.
Construction/Loadline › Hull › Bracket
Issued 8 March 2012 Resolved
Crop and renew fractured bracket in the No. 2P void, adjacent to the cargo tank.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 April 2012
Resolved 19 April 2012
Resolution: Verified satisfactory repairs.
Construction/Loadline › Hull › Transverse Frame
Issued 8 March 2012 Resolved
Repair the pin-hole leak in the port forepeak, adjacent to the forward bulkhead, inboard side, on the No. 1P cargo tank.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 April 2012
Resolved 19 April 2012
Resolution: Verified satisfactory repairs. Witnessed satisfactory air test of weldment.
Electrical › Electrical Distribution System (service) › Cable
Issued 8 March 2012 Resolved
Cable installed in the No. 7P void needs to have chaffing gear installed in the vicinity of where the cable jacket has started to fray at the packing gland; adequate supports need to be installed for entire length of cable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 April 2012
Resolved 19 April 2012
Resolution: Verified satisfactory repairs.
Construction/Loadline › Hull › Stringer
Issued 8 March 2012 Resolved
Crop and renew wasted stringer in the No. 8S void (2nd longitudinal stringer, inboard of the bilge knuckle).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2012
Resolved 19 April 2012
Resolution: Verified satisfactory repairs.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 March 2012 Resolved
Replace or renew wasted ladder rungs in the No. 7S void (aft).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2012
Resolved 19 April 2012
Resolution: Verified satisfactory repairs.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 March 2012 Resolved
Remove/descale all loose accumulated corrosion scale in the port forepeak, under the WTH., to the extent necessary to determine a thorough examination of this area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2012
Resolved 19 April 2012
Resolution: Verified satisfactory repairs.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 1 July 2009 Resolved
Liferaft hydrostatic release unit has expired. Remove and replace the liferaft hydrostatic release unit IAW 46 CFR 199.190 (h).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2009
Resolution: Removed and replaced the liferaft hydrostatic release unit IAW 46 CFR 199.190 (h).
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 20 June 2007 Resolved
Provide working indicator for the position of all non-rising stem cargo valves to include stenciling the "Open" and "Closed" position.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 14 August 2007
Resolution: New valve indicators were installed.
Construction/Loadline › Hull › Transverse Frame
Issued 12 March 2007 Resolved
Crop and Renew transverse bulkhead 24"x18" IVO 1st + 2nd bulkhead fwd of ladder 4 frames from bottom #3 Stbd Wing Void.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2007
Construction/Loadline › Hull › Weld
Issued 12 March 2007 Resolved
Weld Cargo leak IVO center line in Bow Rake
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2007
Construction/Loadline › Hull › Transverse Frame
Issued 12 March 2007 Resolved
Weld Pin Hole leak IVO frame 4,5,6 in #6 Port void at cargo tank.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 March 2007
Construction/Loadline › Hull › Bracket
Issued 12 March 2007 Resolved
Gauge and weld tripped bracket in #2 stbd void 4 frames fwd of ladder 5' up from bottom.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2007
Construction/Loadline › Hull › Bracket
Issued 12 March 2007 Resolved
Gouge and weld tripped bracket Fwd end of # 4 Stbd void 3' up from bottom
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2007
Construction/Loadline › Hull › Stiffener
Issued 12 March 2007 Resolved
Gauge and Weld Trip Bracket at Frame 44 in #5 Stbd void 4th frame down from deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2007
Construction/Loadline › Hull › Weld
Issued 12 March 2007 Resolved
Gauge and Weld broken weld in #1 port Void 4th bay fwd of ladder transverse bulkhead inboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 March 2007
Construction/Loadline › Hull › Weld
Issued 12 March 2007 Resolved
Gauge and Weld fractured weld in #1 Stbd void aft bay transverse bulkhead inboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2007
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 11 May 2006 Resolved
Replace or remove electronic cargo tank gauging system. Any system, whether required or not, must be working properly to prevent accidents from occurring.
Due 26 July 2006
Resolved 26 June 2006
Resolution: Received fax confirmation from [name withheld], Bouchard and General Marine Electric that all Bergan Radar System (closed electronic gauging system) has been removed.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 12 April 2006 Resolved
Prove proper operation of closed gauging system prior to carriage of cargo requiring vapor control.
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 11 May 2006
Resolution: Amended this CG-835.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 12 April 2006 Resolved
Ensure audible alarms for tank high level and overfill are able to be heard by tankerman at all locations on deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2006
Resolution: Tests done with cargo pumps running. Alarms could not be heard. Alarms can be heard with pumps off, which would be normal ops when loading and when required to utilized.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 12 April 2006 Resolved
Provide cargo gear certificate or test records for both deck cranes rated at 6,000 pounds
Due 12 May 2006
Resolved 11 May 2006
Resolution: Company has downgraded the SWL of both cranes to 3,000 lbs. Cranes are stenciled with the new SWL and have been weight tested to 1.5x the new SWL.
Communications › Radio Communications › EPIRB
Issued 12 April 2006 Resolved
Replace broken antena for 406 EPIRB, vessel restricted to 3NM as a permissively manned barge.
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 11 May 2006
Resolution: New EPIRB and hydrostatic release have been installed.
Deck/Cargo › Cargo Heating › General
Issued 12 April 2006 Resolved
Make proper repairs to #1 Thermal Fluid Heater, inop blower motor.
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 11 May 2006
Resolution: New blower has been installed and tested. Also checked the following random safties :Low Fuel, Low Combustion Air Pressure, and Flameout. All sat.
Deck/Cargo › Cargo Heating › General
Issued 12 April 2006 Resolved
Replace broken sight glass on #2 Thermal Fluid Heater.
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 11 May 2006
Resolution: Renewed sight glass.
Engineering › Generator (propulsion-electric) › Breaker Circuitry
Issued 12 April 2006 Resolved
#3 Generator inop, tagged out during inspection. prove proper operation and conduct tests prior to placing in service.
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 11 May 2006
Resolution: Tested sat.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 12 April 2006 Resolved
6 person life raft hydrostatic release expired. vessel restricted to unmanned transits until replaced.
Action required: 705 - Other - as specified
Resolved 11 May 2006
Resolution: New hydrostatic release installed.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 6 June 2005 Resolved
Provide sign in vicinity of visual high level and overfill indicators which reads "HIGH LEVEL ALARM" and TANK OVERFILL ALARM" respectively as required by 46 CFR 39.20-7 (c) and (d).
Due 26 June 2006
Resolved 26 June 2006
Resolution: Corrected, received confirmation from [name withheld], Bouchard transportation. Faxed correction report.
Construction/Loadline › Markings › Load Line Mark
Issued 15 July 2004 Resolved
Permanently affix and re-paint faded loadline.
Due 15 August 2004
Resolved 30 August 2004
Deck/Cargo › Cargo Stowage › General
Issued 15 July 2004 Resolved
Replace corroded stern void vent.
Due 15 August 2004
Resolved 30 August 2004
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 15 July 2004 Resolved
Mark all cargo tank valve indicators with "open" and "closed".
Due 15 August 2004
Resolved 16 July 2004
Deck/Cargo › Holds/Tanks › Hatch
Issued 15 July 2004 Resolved
Mark all voids with "Danger - Keep Out".
Due 15 August 2004
Resolved 16 July 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 15 July 2004 Resolved
Replace all mufflers (for cargo pumps) as original.
Due 15 August 2004
Resolved 30 August 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 July 2004 Resolved
Renew hand rail courses stbd side by the house.
Due 15 August 2004
Resolved 30 August 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 15 July 2004 Resolved
Renew corroded cover on #8S cargo tank gauging system junction box enclosure.
Due 15 August 2004
Resolved 30 August 2004
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 15 July 2004 Resolved
Re-stencil vapor control pipes, stbd side, with "vapor".
Due 15 August 2004
Resolved 16 July 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Bolts
Issued 15 July 2004 Resolved
Replace broken wingnut and bolt on #2S cargo tank view port.
Due 15 August 2004
Resolved 30 August 2004
Deck/Cargo › Mooring/Anchoring › Clutch
Issued 15 July 2004 Resolved
Replace missing hydraulic control handle for anchor windlass.
Due 15 August 2004
Resolved 30 August 2004
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 15 July 2004 Resolved
Place all flammable materials in paint lock or remove from barge.
Due 15 August 2004
Resolved 16 July 2004
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 15 July 2004 Resolved
Remove all open containers from paint locker.
Due 15 August 2004
Resolved 16 July 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 15 July 2004 Resolved
Replace starter on #3 cargo pump and prove proper operation.
Due 15 August 2004
Resolved 16 July 2004
Electrical › Electric Generation Source (service) › Generator
Issued 15 July 2004 Resolved
Prove proper operation of generators and shutdowns.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 2 September 2003 Resolved
Install fixed firefighting system on deck paint lockers.
Due 1 October 2003
Resolved 16 October 2003
Resolution: Corrected.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 12 August 2003 Resolved
Place onboard vessel a current DAPI Enrollment certificate.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 August 2003
Resolved 12 August 2003
Resolution: Corrected
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 12 August 2003 Resolved
Repair slight leak in cargo pipeline, port side, inboard pump at the swival flange. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 17 November 2003
Pollution Prevention/Response › Prevention Equipment
Issued 12 August 2003 Resolved
Place a plug in the wave break starboard side bow. LEGACY COMPONENT DESC: Coamings
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 2 September 2003
Resolution: Plugs placed in wave break starboard side bow.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 12 August 2003 Resolved
Place piping diagram with location of all valves and overspill device located in the diagram.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 August 2003
Resolved 12 August 2003
Resolution: Corrected
Deck/Cargo › Mooring/Anchoring
Issued 12 August 2003 Resolved
Re-install level wind on the anchor windless. LEGACY COMPONENT DESC: Winch
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 November 2003
Resolved 17 November 2003
Deck/Cargo › Mooring/Anchoring
Issued 12 August 2003 Resolved
Repair the brake on the port side stern capstan. LEGACY COMPONENT DESC: Capstan
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 November 2003
Resolved 17 November 2003
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 12 August 2003 Resolved
Conduct annual class survey before next cargo operation.
Action required: 705 - Other - as specified
Due 15 August 2003
Resolved 15 August 2003
Resolution: Corrected.
Deck/Cargo › Cargo Heating
Issued 5 June 2002 Resolved
Demonstrate proper operation of visual indicators (lamps) for thermal fluid heater panels 1 & 2. LEGACY COMPONENT DESC: Thermal fluid heater control panels
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2002
Resolved 7 December 2002
Resolution: Witnessed satisfactory operation of visual indicators for TFH expansion tank level.
Electrical › Lighting (service)
Issued 5 June 2002 Resolved
Re-attach lighting fixtures & conduit (external) for accomodation house. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2002
Resolved 7 December 2002
Resolution: Lighting fixtures and conduit secured.
Deck/Cargo › Cargo Heating
Issued 5 June 2002 Resolved
Repair leaking & OOC cargo tank temperature gauges for #7 & #5 port cargo tanks. LEGACY COMPONENT DESC: Cargo hold temperature gauges
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2002
Resolved 7 December 2002
Resolution: Temperature gauges removed and sending pipes capped. Observed no leaking.
Electrical › Electric Generation Source (service)
Issued 5 June 2002 Resolved
Demonstrate proper operation of #4 (house) generator. LEGACY COMPONENT DESC: Generator
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2002
Resolved 7 December 2002
Resolution: Witnessed satisfactory operation.
Documentation › Logs/Records
Issued 5 June 2002 Resolved
Maintain Oil Record Book Part 1. LEGACY COMPONENT DESC: Oil Record Book
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 1 July 2002
Engineering
Issued 18 April 2001 Resolved
REPAIR/REPLACE LUBE-OIL SWITCH #1 GENERATOR.
Condition: Unknown
Due 18 April 2001
Resolved 18 April 2001
Engineering
Issued 18 April 2001 Resolved
REMOVE PETCOCK ON SECONDARY FUEL FILTER ON #1, 2 AND 3 GENERATORS AND REPLACE WITH PLUG.
Condition: Unknown
Due 18 April 2001
Resolved 18 April 2001
Engineering
Issued 18 April 2001 Resolved
REPAIR/REPLACE EXHAUST MANIFOLD GASKETS ON #2 GENERATOR.
Condition: Unknown
Due 18 April 2001
Resolved 18 April 2001
Engineering
Issued 18 April 2001 Resolved
INSERT PLUGS IN PRIMARY FUEL STRAINERS ON #2 GENERATOR.
Condition: Unknown
Due 18 April 2001
Resolved 18 April 2001
Accommodation/Occupational Safety
Issued 18 April 2001 Resolved
ALL ELECTRICAL EQUIPMENT IN GALLEY MUST BE PROPERLY GROUNDED AND SECURED.
Condition: Unknown
Due 18 April 2001
Resolved 18 April 2001
Electrical
Issued 18 April 2001 Resolved
REPLACE BATTERY ON HOUSE GENERATOR.
Condition: Unknown
Due 18 April 2001
Resolved 18 April 2001
Electrical
Issued 18 April 2001 Resolved
PROVE LUBE OIL SHUTDOWN, HIGH WATER TEMP AND OVERSPEED ON HOUSE GENERATOR.
Condition: Unknown
Due 18 April 2001
Resolved 18 April 2001
Electrical
Issued 18 April 2001 Resolved
SECURE GAUGE PANEL ON #2 GENERATOR.
Condition: Unknown
Due 18 April 2001
Resolved 18 April 2001
Electrical
Issued 18 April 2001 Resolved
PROVE LUBE OIL SHUT DOWN ON #2 GENERATOR.
Condition: Unknown
Due 18 April 2001
Resolved 18 April 2001
Electrical
Issued 18 April 2001 Resolved
REPAIR/PROVE HIGH WATER TEMP GAUGE ON #3 GENERATOR.
Condition: Unknown
Due 18 April 2001
Resolved 18 April 2001
Electrical
Issued 18 April 2001 Resolved
PROVE LUBE OIL SHUTDOWN ON #3 GENERATOR.
Condition: Unknown
Due 18 April 2001
Resolved 18 April 2001
Deck/Cargo
Issued 18 April 2001 Resolved
#3 PUMP LEAKING EXCESSIVE OIL. PUMP IS TO BE SHUTDOWN AND NOT USED FOR ANY CARGO OPERATIONS UNTIL IT IS INSPECTED BY CLASS (ABS) OR A CG INSPECTOR.
Condition: Unknown
Due 18 April 2001
Resolved 18 April 2001
Construction/Loadline
Issued 16 February 2001 Resolved
VESSEL AUTHORIZED TO TRANSIT FROM BONNET CARRE ANCHORAGE TO HALTER REPAIR FACILITY IN THE INDUSTRIAL CANAL (WHEN WEATHER SUBSIDES) TO COMPLETE REPAIRS TO HULL DAMAGE ON PORT BOW.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Unknown
Issued 16 February 2001 Resolved
VESSEL NOT AUTHORIZED TO LOAD CARGO UNTIL THE STABILITY AND TRIM BOOKLET, REFERENCED IN THE COI, IS PRODUCED.
Condition: Unknown
Due 16 February 2001
Resolved 16 February 2001
Electrical
Issued 26 April 1999 Resolved
PROVE PROPER OPERATION OF ALL PAINTED OVER EXPLOSION PROOF FITTINGS.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Construction/Loadline
Issued 26 April 1999 Resolved
LUBE AND FREE UP ACOMMODATION SPACE EMERGENCY ESCAPE HATCH, FORWARD RAKE HATCH AND VENTILATION HATCH CLOSURES.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Lifesaving
Issued 26 April 1999 Resolved
PROVIDE PROOF OF NOAA EPIRB REGISTRATION, HYDROSTATIC RELEASE REPLACEMENT AND BATTERY INSTALLATION DATE.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Deck/Cargo
Issued 26 April 1999 Resolved
STENCIL DO NOT ENTER ON TANK TOPS.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Deck/Cargo
Issued 26 April 1999 Resolved
PROVE PROPER OPERATION OF NO 2 PORT HIGH LEVEL/OVERFILL ALARMS.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Lifesaving
Issued 26 April 1999 Resolved
PROVIDE PROPER PAINT LOCKER AND ASSOCIATED FIRE PROTECTION.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Electrical
Issued 26 April 1999 Resolved
CLEAR ELECTRICAL GROUNDS IWO PANEL LP1.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Engineering
Issued 26 April 1999 Resolved
STENCIL EMERGENCY FUEL SHUT OFFS FOR THERMAL FLUID HEATERS.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Deck/Cargo
Issued 3 October 1997 Resolved
Submit to Marine Safety Center, Washington D.C. for approval plans outlining proposed changes to the fluid tank for the thermal fluid heater system. After approval have changes inspected by local OCMI.
Condition: Unknown
Due 3 October 1997
Resolved 3 October 1997
Engineering
Issued 1 May 1997 Resolved
Demostrate proper operation of low lube oil pressure switches for all generators.
Condition: Unknown
Due 1 May 1997
Resolved 1 May 1997
Deck/Cargo
Issued 1 May 1997 Resolved
Make permanent repairs to fracture in fluid tank for thermal fluid heater._x001C_Fracture in way of forward inboard portion of tank.
Condition: Unknown
Due 1 May 1997
Resolved 1 May 1997
Deck/Cargo
Issued 1 May 1997 Resolved
Demonstrate proper operation of low level switch for fluid thermal heater prior to usage.
Condition: Unknown
Due 15 June 1997
Resolved 6 May 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.