Records from 1992 to 2026. Most recent: inspection, 19 March 2026.
Inspection history · 63
19 March 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8329011
19 March 2026
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8358210
2 March 2026
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8312689
22 May 2025
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8141169
1 May 2023
MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7676872
14 April 2023
ISM Oversight · TPO Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7670358
3 February 2023
Deficiency Check · Initial Certification · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7630621
14 July 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7506679
6 May 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7445234
10 December 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7366248
27 July 2020
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7017630
9 June 2020
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6972207
26 February 2020
Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6916063
9 February 2020
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6905488
8 February 2020
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6908048
5 September 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6532634
26 July 2018
In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6492091
25 July 2018
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6517437
13 July 2017
Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6205776
11 May 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6333323
3 August 2015
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5214790
1 July 2015
Damage Survey · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5169715
29 June 2015
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5168350
29 June 2015
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5177913
4 June 2015
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5219182
30 April 2015
MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5114266
24 April 2015
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5110143
21 November 2013
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4756688
26 October 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4741504
25 October 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4741404
13 December 2012
Industry Initiated Exam · MTSA Verification · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4501423
17 April 2012
Type not recorded
No type recorded · USCGC CLEAT (WYTL 65615) · USCG East District (CGD-E) · Activity 4289412
30 March 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4294841
3 February 2012
Administration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4237547
8 April 2010
Administration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3711786
14 May 2009
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3475034
8 January 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2853151
8 January 2007
Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2853567
29 December 2006
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2847734
11 August 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2743925
7 April 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2627048
26 February 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2593394
3 February 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2578810
11 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2308265
27 May 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2079898
9 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1962312
18 November 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1950609
22 November 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1709287
28 October 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1697009
20 November 2001
Type not recorded
No type recorded · USCGC ADAK (WPB 1333) · USCG Northeast District (CGD-NE) · Activity 1523964
8 November 2001
Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1382431
13 October 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 98823
8 January 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 46996
15 December 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 26942
29 June 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 75384
7 October 1996
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 396205
5 May 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 200943
5 May 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 757587
1 April 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 85002
15 June 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 367789
10 January 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 154015
14 January 1993
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 355697
28 May 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 118241
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 March 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Sector New Orleans Duty Marine Inspector received notification that the M/V TURQUOISE COAST's starboard propeller became disconnected while underway due to unknown cause, resulting in loss of propulsion from their starboard engine.
Vessel restricted from departing Belle Chasse Launch River Mile 75 until a transit plan is submitted to [email withheld] and approved by Coast Guard Sector New Orleans.
31MAR2026: Amended deficiency:
Vessel is authorized one time transit to Poland Ave for lightering operations. Upon completion of lightering operations, vessel is authorized one time lightship transit to National Maintenance and Repair for vessel repairs. Both transits are to be conducted with tug assist as outlined in submitted transit plan. Vessel is restricted from all other movement until a TPO report attesting to complete and satisfactory repairs is submitted to and reviewed by Coast Guard Sector New Orleans.
Action required: 60 - Rectify deficiencies prior to movement
Due 20 March 2026
Resolved 4 May 2026
Resolution: Received, reviewed, and accepted the submitted RINA Class Report attesting to the re-fitting of the starboard tailshaft
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 22 May 2025
Resolved
An owner or operator of a U.S. flag vessel, which is subject to the International Convention for Safety of Life at Sea, 1974, (SOLAS), must be in compliance with the applicable requirements of SOLAS Chapter XI-1, SOLAS Chapter XI-2 and the ISPS Code, part A. Ship Security Alert System cannot be tested without sending an alert.
Vessel restricted to domestic voyages only.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 September 2025
Resolution: Tech cleared with report.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 July 2020
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 50% of the vessels that has not obtained a valid COI. The vessel shall be
made available for a Coast Guard COI inspection within 90 Days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the
vessel may no long be permitted to operate.
Action required: 60 - Rectify deficiencies prior to movement
Due 27 October 2020
Resolved 10 December 2021
Resolution: Vessel was sold in October 2021. Vessel is currently under the owner/operator Dann Marine Towing, LC which is currently in compliance with the 2021 issued COI target percentage of 75%.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 July 2018
Resolved
Fire extinguisher in galley is not CG approved. Remove extinguisher and replace with CG approved fire extinguisher.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2018
Resolved 5 September 2018
Resolution: New extinguisher is CG approved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 July 2018
Resolved
Vsl is not able to conduct main engine high cooling water temp alarm. Provide means to conduct test to the satisfaction of attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2018
Resolved 5 September 2018
Resolution: Conducted satisfactory testing of MDE High temp alarms
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 July 2018
Resolved
The starboard main engine has excessive exhaust leaks at multiple locations. Conduct repairs and test in the presence of CG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2018
Resolved 5 September 2018
Resolution: Conducted operational test of MDE. No exhaust leaks were found.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 8 January 2007
Resolved
Faulty control amplifier causing electrical shutdown of steering system.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 January 2007
Resolved 9 January 2007
Resolution: Third party technician replaced faulty control amplifier.