AYA 215

AYA 215 is a 1999 tank barge. The Coast Guard has recorded 68 inspections since 1999, most recently in August 2018, along with 173 deficiencies — 40 with no resolution recorded —, 1 operational control and 6 casualty investigations between 2009 and 2018.

Records from 1999 to 2018. Most recent: inspection, 16 August 2018.

Built
1999
Last inspected
16 August 2018
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WCY8682
472489
Flag
UNITED STATES
Maury page id
psix-472489

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspections, by type

…with no type recorded21
…past their stated due date39
Years with a record 20 calendar years (1999–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it5357 - Convention (Subpart B), Net Ton
18765 - Dead Weight, Ton
22697 - Displacement, Ton
8721 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 2

Inspection history · 68

16 August 2018 Administrative Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6514068
26 July 2018 Damage Survey · Permit to Proceed · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6491700
25 July 2018 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6517437
12 July 2018 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6478800
8 November 2017 MTSA Verification · MARPOL Annex VI Survey · MARPOL Annex I Examination · Deficiency Check · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6299500
24 October 2017 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6294726
24 October 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6296095
24 February 2017 Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6093872
7 October 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6029547
1 September 2016 MTSA Verification · MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5986397
7 April 2016 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5902146
3 March 2016 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5826651
2 February 2016 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5806167
19 January 2016 MARPOL Annex I Examination · MTSA Verification · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5799399
13 April 2015 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5102243
12 May 2014 Internal Structural Exam · In-Service Inspection · Examination of Repairs · Drydock Exam · COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4856617
5 October 2013 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4730825
20 August 2013 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4691264
7 August 2013 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4678784
13 November 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4510055
12 July 2012 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4384887
30 June 2012 MARPOL Annex I Examination · MTSA Verification · MARPOL Annex VI Survey · Periodic Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4313748
15 May 2012 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4313633
30 April 2012 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4298725
29 July 2011 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4104328
22 July 2010 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3802898
1 February 2010 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3673406
27 April 2009 Cargo Tank Internal · Administrative Inspection · Ballast Water Examination · DAPI Audit · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3462295
10 March 2009 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3431101
16 January 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3395171
13 January 2009 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3393256
6 August 2008 MTSA/ISPS Verification · MARPOL Annex I Examination · MARPOL Annex V Examination · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3291005
31 May 2007 Deficiency Check · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2990808
23 April 2007 MARPOL Annex I Examination · MARPOL Annex V Examination · Periodic Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2913448
11 August 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2743856
6 July 2006 MARPOL Annex V Examination · MARPOL Annex II Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2703594
15 March 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2603045
3 February 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2578880
26 July 2005 MTSA Verification · MARPOL Annex V Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2440251
28 May 2005 MTSA/ISPS Verification
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2376231
20 April 2005 Type not recorded
No type recorded · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 2338546
14 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2309844
19 November 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2244336
28 May 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2080659
6 May 2004 Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2060475
19 April 2004 Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2047872
9 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1962410
19 September 2003 In-Service Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1911762
19 August 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1880605
11 June 2003 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1815184
27 May 2003 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1796723
15 April 2003 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1779040
26 July 2002 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1652577
6 May 2002 Re-Inspection · Internal Structural Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1608830
27 July 2001 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1070263
26 April 2001 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1066534
22 March 2001 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1059830
14 March 2001 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1430998
26 February 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 108771
14 December 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 54100
11 October 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 492646
29 June 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 532047
12 May 2000 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1399383
11 January 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 273597
15 July 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 481162
12 June 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 453359
2 April 1999 Construction Oversight · Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1421639
10 January 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 273572

Deficiency record · 173

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 5 January 2019 No resolution recorded
While gauging was being conducted in the #1 Port and Starboard tanks on 19DEC18, all original under deck logitudinals in those tanks were measured by hand and were in excess of 20% wastage. Crop and renew all original under deck longitudinals in the #1 Port and Starboard cargo tanks. 46CFR31.10-25
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2019 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 December 2018 No resolution recorded
Gauging conducted on the #1 Port and Starboard and #2 Starboard cargo tanks reveled multiple transverse frames and cargo bulkheads that were wasted beyond allowable tolerances. Conduct gauging on the remaining transverse frames and under deck longitudinals on the #2 Port and #3-8 P/S cargo tanks in the presence of a CG Marine Inspector to determine if the remaining steel is within allowable tolerances. 46CFR31.10-25
Action required: 17 - Rectify deficiencies prior to departure
Due 19 December 2018 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 December 2018 No resolution recorded
Provide a repair proposal addressing all under deck longitudinals, transverse frames, and cargo tank bulkheads that were found to be wasted beyond allowable tolerances for approval prior to repair work being conducted on these structural members. 46CFR31.10-25
Action required: 17 - Rectify deficiencies prior to departure
Due 19 December 2018 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 17 December 2018 No resolution recorded
After the repair proposal for deck platting was submitted to the Marine Inspector and ABS additional deck platting was called out by Coast Guard and ABS as needing to be replaced. See attachment #1 to this form and crop and renew all highlighted areas to the satisfaction of the attending marine inspector. 46CFR31.10-25
Action required: 17 - Rectify deficiencies prior to departure
Due 17 December 2018 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 17 December 2018 No resolution recorded
During inspection of the under deck framing in the #1 and #2 P&S cargo tanks, multiple transverse frames and under-deck longitudinals appeared to be substantially wasted. Conduct gauging on transverse frames and underdeck longitudinals in the presence of a CG Marine Inspector to determine if the remaining steel is within allowable tolerances. 46CFR31.10-25
Action required: 17 - Rectify deficiencies prior to departure
Due 17 December 2018 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 August 2018 No resolution recorded
Complete audio gauging on main deck to determine if remaining steel is within allowable tolerances in the presence of a CG marine inspector. 46CFR31.10-25
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2018 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 August 2018 No resolution recorded
Provide all necessary documentation for reduce scantling acceptance to Marine Safety Center. 46CFR31.10-25
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2018 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 August 2018 No resolution recorded
Correct all outstanding CG-835 deficiencies. Prior to departure.
Condition: Improper/Lack of Maintenance
Due 24 August 2018 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 August 2018 No resolution recorded
Prior to any repair work being conducted, submit a repair proposal addressing all gauged sections of the main deck taken from 16AUG18 to 20SEP18 that exceed maximum wastage allowance.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 October 2018 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 26 July 2018 No resolution recorded
#1 STBD cargo tank is leaking product into the STBD forepeak thru crack due to damage/deterioration IWO longitudinal bulkhead. Crop and renew prior to carrying cargo to satisfaction of attending marine inspector. PTP to be issued for transit to shipyard in Tampa, FL.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 July 2018 No resolution recorded
Fixed FF installation for port side paint locker has empty CO2 bottle attached (on single bottle installation) rendering no protection for space. Replace bottle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2018 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 July 2018 No resolution recorded
Fixed fire extinguisher installation for STBD side paint locker has broken bracket for CO2 bottle. Replace bracket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2018 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 26 July 2018 No resolution recorded
Fuel supply hoses on the #1 and #3 cargo pump prime movers are chaffed. Replace hoses.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2018 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 26 July 2018 No resolution recorded
Crank case vent (breather) leaking water on #1 cargo pump prome mover. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2018 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 July 2018 No resolution recorded
Unapproved temporary installation of electrical extension cord for both refridgerator and freezer in #1/#2 cargo pump house. Remove temporary installation, make permanent.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2018 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 July 2018 No resolution recorded
Electrical penetration thru deck for port aft mooring winch is wasted, rendering it non-watertight, renew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2018 — due date passed with no resolution recorded
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 26 July 2018 No resolution recorded
SMS has failed to ensure complaince with mandatory rules and regulations, taking into account relevant national and int'l regulations, standards, codes, guidelines when developing procedures and policies for the SMS. SMS must have documents that address vsl maintenance procedures. It appears that vsl maintenance is not being adequately addressed as evidenced by USCG annual insp (was actually in service insp) on 17Jul18, ABS annual inspection attempt and resultant worklist issued on 25Jul18 that must be addressed prior to ABS reattendance to conduct annual ispections, and deficiencies issued herein.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2018 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 July 2018 Resolved
Ship service generators #2 &#3 engine over-speed did not shutdown during testing. PRIOR to departure provide tech rep and make arrangements for Coast Guard MI attendance.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 July 2018
Resolved 19 July 2018
Resolution: CG MI in company with tech rep successfully conducted overspeed shutdowns.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 17 July 2018 No resolution recorded
Both: PORT side Cargo Header #1 cargo valve, and STBD side Cargo Header #2 cargo valve are leaking. PRIOR to cargo operations repair/replace valves to a non-leaking status.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 July 2018 No resolution recorded
OI calls for (01) BV fire extinguisher. Vessel has (02) “permanently” mounted on deck. The storage requirements for this fire fighting requires not be stored in sunlight and “may explode if heated”.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 17 July 2018 No resolution recorded
Prior to loading cargo repair/replace high level overfill devices. Every indicator pull stick onboard is extremely difficult to operate, several did not alarm as required. Most devices at tank will not seal with screw cap due to rust and wastage of threads. Inspector doubts that system would function as required in the vent of alarming situation. Tank indicators need maintenance or replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 17 July 2018 No resolution recorded
#1 & #2 Cargo Pump Prime Mover, F/O Leak at Valve and multiple L/O leaks, specifically on outboard side of engines.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 17 July 2018 Resolved
#2 TFH unapproved fuel piping arrangement and is leaking fuel at screw coupling.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018
Resolved 19 July 2018
Resolution: MI inspected fitting determined that material is iron and verified sealing surfaces within fitting assenbly. Verified firring with tech rep. as proper fittting required.Tightened fitting and operated machinery sat. piping no longer leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 July 2018 Resolved
Ship Service generator observed multiple leaks, specifically at the governor. Vessel had engines serviced but still leaking.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018
Resolved 19 July 2018
Resolution: operated machinery with tech rep. no leaks observed. All sat.
08 - Alarms › N/A - No Subsystem › Boiler alarm
Issued 17 July 2018 No resolution recorded
TFH Alarms, on deck visual & audible alarms on top of the TFH house are inoperable. Alarms at watch station and inside TFH room do alarm as designed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 July 2018 No resolution recorded
Emergency lighting in cargo pump room inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 17 July 2018 No resolution recorded
#2 Cargo Pump Guard around fan is broken on outboard side.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 17 July 2018 No resolution recorded
#1 TFH strainer, observed leaking fluid around top canister seal & service pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 July 2018 No resolution recorded
(02) Fire Fighting outfits provided on board, seal are rotted and non functioning on one of the masks.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 17 July 2018 No resolution recorded
#2 Cargo Pump RPM gauge inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 17 July 2018 No resolution recorded
Electronic gauging/ullage system not functioning as designed, tank indicators unreadable and main tank capacity indicator at watch station not calibrated reading in error.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 17 July 2018 Resolved
TFH supply tank, tank level indicator is stuck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018
Resolved 19 July 2018
Resolution: Tech rep provided objective evidence that the sight glass is functioning as designed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 17 July 2018 No resolution recorded
Crane hydraulic hoses have no tags, could not provide any testing or installation information. Crew stated that they operate to failure then replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 17 July 2018 No resolution recorded
STBD side ballast tanks #5, #7, #8 will not pump down completely. Suction piping system may be wasted and worn.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 July 2018 No resolution recorded
Port side start battery for ballast pump not stored in provided battery box. Located on the deck not secured.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 17 July 2018 No resolution recorded
Throughout vessel there are several standard lights that are extinguished and not illuminating to include: Cargo Pump Room, Thermal Fluid Heater room, Deck lighting (including STBD side forward flood light). Several are missing covers or/and covers are broken.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 17 July 2018 No resolution recorded
Several electrical wire runs, F/O & Hydraulic piping supports on deck are deteriorated beyond function.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 17 July 2018 No resolution recorded
Fwd hold hatches are spring assisted hatches. Springs are broken and non-functioning.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 July 2018 No resolution recorded
Ballast pump amp meters inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 July 2018 No resolution recorded
Ground Detection panel in generator room has several lights that do not illuminate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 17 July 2018 No resolution recorded
Equipment not secured: 04 refrigerators on board (03) in cargo pump room, (01) at watch station/galley; clothes washer in watch station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 17 July 2018 Resolved
Vapor hose provided is wasted and worn, spiral support banding around hose is wasted and deteriorated in many areas.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018
Resolved 19 July 2018
Resolution: Vessel removed Vapor hose from service and from the vessel.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 17 July 2018 No resolution recorded
Cargo Pump relief valve tags are missing and tamper seals are deteriorated beyond function. Cargo pump relief valves were tested on 27FEB2018.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 July 2018 No resolution recorded
#1 Air compressor relief valve handle broken.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 17 July 2018 No resolution recorded
Draft marks are faded and difficult to determine while onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 13 July 2018 Resolved
MSD Tank is leaking into STBD aft void. Sink, shower, and toilets were secured to barge crew.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Due 18 July 2018
Resolved 19 July 2018
Resolution: Inspected newly installed MSD. Installation is as per manufacture specifications and approved by ABS Class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 July 2018 Resolved
#2 Thermal Fluid heater high temp limit switch malfunctioning.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 18 July 2018
Resolved 19 July 2018
Resolution: In company with tech repconducted inspected and tested all assoc. TFH alarms.
Operations/Management › Vessel Activity › Other
Issued 9 November 2017 Resolved
Vessel is prohibited movement and cargo ops until such time as satisfactory air test of insert is conducted and vessel condition is to satisfaction of attending marine inspector to include completion of periodic inspection and repair check.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 November 2017
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 November 2017 Resolved
Install rails for stovetop in galley
Action required: 705 - Other - as specified
Due 9 November 2017
Resolved 14 November 2017
Electrical › Electrical Distribution System (service) › Panelboard
Issued 8 November 2017 Resolved
Update breaker panel and replace doors on outside of accomodation space.
Action required: 705 - Other - as specified
Due 9 November 2017
Resolved 14 November 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 8 November 2017 Resolved
Replace water laden outdoor light outside #1 & #2 pumphouse.
Action required: 705 - Other - as specified
Due 8 November 2017
Resolved 9 November 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 November 2017 Resolved
Secure dead end wires on green junction box inside forepeak entrance.
Action required: 705 - Other - as specified
Due 9 November 2017
Resolved 9 November 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 8 November 2017 Resolved
Replace open light socket in forepeak.
Action required: 705 - Other - as specified
Due 9 November 2017
Resolved 9 November 2017
Electrical › Lighting (service) › Switch
Issued 8 November 2017 Resolved
Replace light switch outside accomodation space with original switch.
Action required: 705 - Other - as specified
Due 9 November 2017
Resolved 9 November 2017
Engineering › Diesel Engine (auxiliary) › Block
Issued 26 October 2017 Resolved
Provide technicians report to attending USCG MI providing operational readiness status of the #2 generator to the satisfaction of the MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2017
Engineering › Diesel Engine (auxiliary) › Block
Issued 26 October 2017 Resolved
Provide technicians report to attending USCG MI providing operational readiness status of the #1 & #2 Cargo Pump Primer Mover (engine) to the satisfaction of the MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2017
Deck/Cargo › Cargo Heating › General
Issued 26 October 2017 Resolved
Remove "jumpers" on Low Fuel Oil PR for both Thermal Fluid Heaters (TFHs). Provide technicians report to attending USCG MI providing operational readiness status of both TFHs and conduct testing of both TFHs to the satisfaction of the attending USCG MI and prior to Grade E Cargoes.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2017
Engineering › Diesel Engine (auxiliary) › Distributor (fuel injection)
Issued 26 October 2017 Resolved
Replace fuel impingment bowls and secure fuel leak on #3 Cargo Pump Prime Mover (engine).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2017
Engineering › Diesel Engine (auxiliary) › Valve
Issued 26 October 2017 Resolved
Secure coolant leak on #3 Cargo Pump Prime Mover (engine).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2017
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 26 October 2017 Resolved
Hydro-test cargo deck line, complete in the presence of a USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2017
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 26 October 2017 Resolved
Adjust packing and packing gland ring on Cargo Pump #1 & #3 to reduce cargo overflow during transfer or provide technicians report to the satisfaction of USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2017
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 26 October 2017 Resolved
Secure fuel leak and repair/renew fuel primer on STBD Ballast Pump.
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 9 November 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 October 2017 Resolved
Repair/renew or secure heater block on PORT Ballast pump engine.
Action required: 705 - Other - as specified
Due 9 November 2017
Resolved 8 November 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 October 2017 Resolved
Repair/renew or secure heater block on STBD Ballast pump engine.
Action required: 705 - Other - as specified
Due 9 November 2017
Resolved 8 November 2017
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 26 October 2017 Resolved
Replace temperature gauge on STBD Ballast pump.
Action required: 705 - Other - as specified
Due 9 November 2017
Resolved 8 November 2017
Construction/Loadline › Hull › Hull Plating
Issued 26 October 2017 Resolved
Provide gauging report for deck/tank-top under STBD Ballast Tank house. If necessary provide repair proposal to USCG MI.
Action required: 705 - Other - as specified
Due 9 November 2017
Resolved 14 November 2017
Construction/Loadline › Hull › Hull Plating
Issued 26 October 2017 Resolved
Provide gauging report for deck/tank-top aft of #1 & #2 Cargo Pump house. If necessary provide repair proposal to USCG MI.
Action required: 705 - Other - as specified
Due 9 November 2017
Resolved 14 November 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 October 2017 Resolved
Repair/renew or secure heater block on #1 Cargo Pump Prime Mover (engine).
Action required: 705 - Other - as specified
Due 9 November 2017
Resolved 8 November 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 October 2017 Resolved
Secure/mount heater electrical box next to #2 Cargo Pump Prime Mover (engine).
Action required: 705 - Other - as specified
Due 9 November 2017
Resolved 9 November 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 October 2017 Resolved
Repair/renew or secure heater block on #3 Cargo Pump Prime Mover (engine).
Action required: 705 - Other - as specified
Due 9 November 2017
Resolved 8 November 2017
Electrical › Electric Generation Source (service) › Generator
Issued 26 October 2017 Resolved
Provide repair proposal for alternator on house generator (#4).
Action required: 705 - Other - as specified
Due 9 November 2017
Resolved 8 November 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 26 October 2017 Resolved
Provide electrical installations plans for the overhead fixture in the head; install light IAW plans.
Action required: 705 - Other - as specified
Due 26 November 2017
Resolved 8 November 2017
Construction/Loadline › Structures › Superstructure
Issued 26 October 2017 Resolved
Provide timeline for weld repair on support bracket for cable run on deck, port side adjacent to #1&#2 Cargo Pump Room admidships.
Action required: 705 - Other - as specified
Due 26 November 2017
Resolved 9 November 2017
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 26 October 2017 Resolved
Replace shattered porthole window on inboard side of #1&#2 Pump Room Building.
Action required: 705 - Other - as specified
Due 26 November 2017
Resolved 9 November 2017
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 26 October 2017 Resolved
Replace smoke detector in crew lounge/office.
Due 26 October 2017
Resolved 26 October 2017
Lifesaving › Inflatable Liferafts › Float Free
Issued 26 October 2017 Resolved
Replace EPRIB hydrostatic release.
Due 26 October 2017
Resolved 26 October 2017
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 26 October 2017 Resolved
Remove electric deep-fat fryer from vessel or install permanent fixed fire system.
Due 26 October 2017
Resolved 26 October 2017
Communications › Alarms/Indicators › General Alarm
Issued 26 October 2017 Resolved
Remove covers and tape from both of the "HOT OIL SYSTEM ALARMS" in the galley.
Due 26 October 2017
Resolved 26 October 2017
Deck/Cargo › Towing › Towline
Issued 26 October 2017 Resolved
Remove tie-back on emergency towing cable.
Due 26 October 2017
Resolved 26 October 2017
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 24 October 2017 Resolved
Provide repair proposal to attending MI for #2 Cargo Pump prior to repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2017
Operations/Management › Pollution › Removal Methods/Procedures
Issued 24 October 2017 Resolved
Clean all cargo and cargo residues to satisfaction of USCG MI prior to cargo operation or leaving Sector Hampton Roads/ Vessel Movement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2017
Engineering › Fuel Oil Service System › Piping
Issued 24 October 2017 Resolved
Repair fuel line to STBD Ballast Water Pump to mitgate active fuel leak prior to cargo operations and to the satisfaction of attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2017
Engineering › Diesel Engine (auxiliary) › Block
Issued 24 October 2017 Resolved
Provide technicians report to attending MI providing operational readiness status of #1 Generator to satisifaction of UCCG [name withheld] exhaust/oil leaks, etc. Unit in disrepair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2017
Engineering › Diesel Engine (auxiliary) › Block
Issued 24 October 2017 Resolved
Provide technicians report to attending MI providing operational readiness status of #3 Cargo Pump Engine to satisifaction of UCCG [name withheld] exhaust/oil leaks, etc. Unit in disrepair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2017
Construction/Loadline › Structures › Deck Plating
Issued 7 March 2017 Resolved
On Port aft void, renew washed out weld where marked at bottom, approx 2 frames forward from ladder. 46 CFR 31.10-21
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 22 March 2017
Resolution: Area was cleaned and rewelded as needed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 March 2017 Resolved
Port FWD void, ladder is dangerous and unsafe, replace as original. 46 CFR 32.02-15
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 22 March 2017
Resolution: Ladder in space was replaced as required.
Engineering › Bilge Water Management System › Valve
Issued 7 March 2017 Resolved
In Number 6 stbd ballast tank, the packing gland is leaking and needs to be renewed or replaced to stop leak. 46 CFR 56.20-9
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 22 March 2017
Resolution: The packing gland was adjusted as needed to prevent it from leaking any further.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 March 2017 Resolved
In number 5 port ballast tank, the railing needs to be re-welded on first landing after first ladder down, the broken weld is causing railing to shift and become dangerous.46 CFR 32.02-15
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 22 March 2017
Resolution: The area was repaired as necessary to resolve the issue.
Construction/Loadline › Markings › Load Line Mark
Issued 1 September 2016 Resolved
Load line mark was faded, directed vessel to re-paint
Due 1 September 2016
Resolved 1 September 2016
Fire Fighting › Portable Foam Applicators › General
Issued 1 September 2016 Resolved
Bottle was wasted at cap
Due 1 September 2016
Resolved 1 September 2016
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 September 2016 Resolved
lifelines on both lifebuoys were wasted
Due 1 September 2016
Resolved 1 September 2016
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 1 September 2016 Resolved
Combustible Gas Indictor calibration bottle was expired
Due 1 September 2016
Resolved 1 September 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 September 2016 Resolved
Loosing wiring inside the hazardous location
Due 1 September 2016
Resolved 1 September 2016
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 1 September 2016 Resolved
#1 cargo pump exhaust muffler is wasted and actively leaking. Restricted cargo operation on #1 cargo pump.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2016
Resolved 1 September 2016
Resolution: Replaced damaged muffler at Port of Port Arthur.
Electrical › Electric Generation Source (service) › Generator
Issued 19 January 2016 Resolved
Generators onboard must be operable. When starting the #2 generator sparks began and alternator was found to be bad. Prior to operation generator must be ran and tested in the presence of a marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 February 2016
Resolution: Generator was started and run without incident. No sparkink was present.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 19 January 2016 Resolved
Each generator prime mover must have an overspeed device independent of governor. Satisfactory tests must be conducted on the #3 and #4 generators in presence of marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2016
Resolved 2 February 2016
Resolution: Tested overspeed on #3 generator, all sat. Collected tech report for repair and testing of #4 generator five days prior.
Electrical › Electric Generation Source (service) › Generator
Issued 19 January 2016 Resolved
Generators onboard must be properly maintained. #4 throttle control does not function as intended. Must be repaired and tested in presence of marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2016
Resolved 2 February 2016
Resolution: Throttle tested without incident.
Deck/Cargo › Cargo Heating › General
Issued 19 January 2016 Resolved
When conducting visual inspection of thermal fluid heater, found it to be leaking fuel. Prior to operation of thermal fluid heater must repair to the satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 February 2016
Resolution: Fuel pump to heater was started and fuel system was pressurized. No evidence of leakage.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 12 May 2014 Resolved
Crew Accomadation space escape hatch gasket damaged.
Action required: 705 - Other - as specified
Resolved 24 October 2014
Resolution: Owner replaced Gasket.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 12 May 2014 Resolved
Audible alarm for cargo high level/overfill inoberable.
Action required: 705 - Other - as specified
Resolved 24 October 2014
Resolution: Owner repaired audible alarm.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 12 May 2014 Resolved
MIS report not on board.
Action required: 705 - Other - as specified
Resolved 24 October 2014
Resolution: Owner requested a copy from consortium. Owner received a copy of MIS report via email.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 5 October 2013 Resolved
While attempting to anchor, vessel lost anchor and 4.5 shots of anchor chain due to failure of anchoring lowering cable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2013
Resolution: Vessel replaced anchor and cable to the satisfaction of the attending class society and provided proof to marine inspector.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 August 2013 Resolved
Replace Emergency Lighting bulbs in accomodation spaces and prove proper operation of emregency lighting.
Action required: 705 - Other - as specified
Due 21 August 2013
Resolved 20 August 2013
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 7 August 2013 Resolved
Prove proper installation of inflatable liferaft.
Action required: 705 - Other - as specified
Due 21 August 2013
Resolved 20 August 2013
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 7 August 2013 Resolved
Paint Vapor Control Line Red/Yellow/Red in accordance with 46 CFR 39-20-1.
Action required: 705 - Other - as specified
Due 21 August 2013
Resolved 20 August 2013
Deck/Cargo › Holds/Tanks › Ullage
Issued 7 August 2013 Resolved
Remove temperature gauge wire from cargo tank hatch covers and prove vapor tightness to the cargo tanks.
Action required: 705 - Other - as specified
Due 7 September 2013
Resolved 20 August 2013
Engineering › Fuel Oil Service System › Gauge
Issued 7 August 2013 Resolved
Replace inoperable temperature gauges on #1 and #3 prime mover.
Due 21 August 2013
Resolved 20 August 2013
Lifesaving › Hand Flares › Storage
Issued 7 August 2013 Resolved
Label storage container and location of distress signals. Distress signals were in unmarked storage container inside the SOPEP locker.
Due 21 August 2013
Resolved 7 August 2013
Resolution: Labeled and moved distress signals inside to accomodation space.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 7 August 2013 Resolved
Show proof of enrollment for drug testing policy for all personnel onboard and last random test.
Due 21 August 2013
Resolved 20 August 2013
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 7 August 2013 Resolved
Show proof of enrollment in benzene montioring program in accordance with 46 cfr 197.540
Due 21 August 2013
Resolved 20 August 2013
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 7 August 2013 Resolved
Replace worn and corroded fire extinguisher brackets on pumproom and prime mover locations.
Due 6 September 2013
Resolved 20 August 2013
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 30 June 2012 Resolved
Install new MSD system tank. System is on board vsl and needs to be installed to satisfaction of USCG.
Condition: Damaged By Earlier Event
Due 30 July 2012
Resolved 2 July 2012
Resolution: Installed new MSD system on vsl.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 27 June 2012 Resolved
Repair/Replace MSD system to ensure proper operation.
Due 27 July 2012
Resolved 30 June 2012
Resolution: All Sat
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 27 June 2012 Resolved
Vsl Stbd aft side Vapor line manifold needs to have a 12 O'Clock position and be painted
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2012
Resolved 30 June 2012
Resolution: All, Sat
Documentation › Certificates/Documents › IOPP Certificate
Issued 17 June 2012 Resolved
Vsl need to have IOPP & IAPP survey. Route is restricted to Oceans not on an International Voyage.
Due 30 July 2012
Resolved 2 July 2012
Resolution: Survey Completed. All Sat
Documentation › Logs/Records › Bunker Delivery Notes/Samples
Issued 17 May 2012 Resolved
Vessel is not retaining bunker samples or bunker notes onboard in proper format.
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Documentation › Logs/Records › Bunker Delivery Notes/Samples
Issued 17 May 2012 Resolved
Bunker samples not taken using proper procedures IAW MEPC.182(59)
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Documentation › Logs/Records › Oil Record Book
Issued 17 May 2012 Resolved
Oil Record Book I entries improperly inputted. Correct IAW MEPC.1/Circ.736/Rev.2
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 30 June 2012
Resolution: ALL Sat
Documentation › Logs/Records › Bunker Delivery Notes/Samples
Issued 17 May 2012 Resolved
Bunker sample labels do not contain all required information. Some samples missing. MARPOL Annex VI, Appendix V
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 17 May 2012 Resolved
Relocate Liferaft in proper place and install accordingly, with Hydrostatic Release Unit
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 17 May 2012 Resolved
Remove and disassemble for inspection all P/V valves. Prove operational.
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 17 May 2012 Resolved
All High and Overfill alarms are inoperative. Repair or replace in kind.
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Deck/Cargo › Cargo Heating › General
Issued 17 May 2012 Resolved
Repair exhaust leaks from vessel on both Thermal Fluid Heaters.
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Deck/Cargo › Ballast › Piping
Issued 17 May 2012 Resolved
Repair wasted ballast piping as per ABS requirements.
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Deck/Cargo › Cargo Heating › General
Issued 17 May 2012 Resolved
Repair leaking thermal fluid valve IVO aft outboard Cargo Pump.
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat.
Construction/Loadline › Hull › Hull Plating
Issued 17 May 2012 Resolved
Provide gauging report for decking IVO Ballast Pump Room.
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 17 May 2012 Resolved
Repair aft outboard cargo pump shaft seal.
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Construction/Loadline › Structures › Deck Plating
Issued 17 May 2012 Resolved
Provide gauging reading for cargo pump room decking.
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 May 2012 Resolved
Re-weld broken hand rail support IVO outboard ballast pump room.
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Construction/Loadline › Markings › Load Line Mark
Issued 17 May 2012 Resolved
Paint deck-line a contrasting color IAW ICLL
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Construction/Loadline › Structures › Door
Issued 17 May 2012 Resolved
Replace gasket on stbd wtd to accommodation space.
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Documentation › Logs/Records › Oil Record Book
Issued 17 May 2012 Resolved
Fix missing signatures in Oil Record Book Part II.
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 17 May 2012 Resolved
Gauge or repair various epoxy/JB Weld patches on vapor line.
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Electrical › Electrical Distribution System (service) › Junction Box
Issued 17 May 2012 Resolved
Properly mount junction box leading to port side cargo pump block heaters.
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Deck/Cargo › Cargo Heating › General
Issued 17 May 2012 Resolved
Demonstrate proper operation of both thermo fluid heaters and safety shutdowns.
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 17 May 2012 Resolved
Provide means to drain or remove discharged oil from containment area. 33CFR155.320(a)(2)
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 17 May 2012 Resolved
Remove or repair exposed witing on cargo deck. (Temperature sensor wiring)
Action required: 705 - Other - as specified
Resolved 2 February 2016
Resolution: Toured entire cargo deck, all stray wiring appeared to be secured satisfactorily.
Construction/Loadline › Hull › Stiffener
Issued 17 May 2012 Resolved
Repair/re-weld outboard stanchion in cargo pump room. (duct taped)
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 May 2012 Resolved
Repair/address 57 items on "B No. 215 Repair List" provided by vessel.
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 May 2012 Resolved
Satisfactorily complete all ABS requirements.
Action required: 705 - Other - as specified
Resolved 30 June 2012
Resolution: All Sat
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 17 May 2012 Resolved
Vsl' no longer uses the catholic protection system. Must be locked out and tagged out.
Condition: Improper/Lack of Maintenance
Due 30 July 2012
Resolved 30 June 2012
Resolution: Al Sat
Communications › Radio Communications › EPIRB
Issued 29 July 2011 Resolved
EPIRB registration pass due date, re-register EPIRB to bring up to date.
Due 14 August 2011
Resolved 18 August 2011
Resolution: Vsl provided proof of a valid EPIRB registration.
Communications › Radio Communications › Cellular Telephone Capability
Issued 29 July 2011 Resolved
The accommodation space antenna is missing stuffing tubes, repair or replace.
Due 14 August 2011
Resolved 15 August 2011
Resolution: Visually inspected stuffing tube.
Lifesaving › Inflatable Liferafts › Markings
Issued 29 July 2011 Resolved
Life markings on accommodation space missing, replace with new placard.
Due 14 August 2011
Resolved 14 August 2011
Resolution: Visually inspect life raft marking.
Deck/Cargo › Holds/Tanks › Coaming
Issued 29 July 2011 Resolved
Pump house WTD's missing or wasted gaskets, repair or replace.
Due 31 October 2011
Resolved 31 October 2011
Resolution: Attended vessel, visually inspected all water tight doors. All doors are repaired satisfactory.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 29 July 2011 Resolved
Portable fire extinguisher is blocked and cannot operate properly. Remove excess paint from locker.
Due 14 August 2011
Resolved 14 August 2011
Resolution: Visually inspected paint locker. All sat
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 29 July 2011 Resolved
Cargo pipe P/V is not operational, repair or replace in-kind.
Due 30 August 2011
Resolved 15 August 2011
Resolution: Vsl replaced the handle on the vacuum side of the P/V valve and demonstrated the assembly works properly.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 29 July 2011 Resolved
Emergency shutdown placard for cargo pumps needs to be replaced.
Due 14 August 2011
Resolved 14 August 2011
Resolution: Visually inspected Emergency Shutdown placard. All Sat
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 29 July 2011 Resolved
Barge Captain is not keeping ballast transfer records IAW ballast water management plan.
Due 14 August 2011
Resolved 14 August 2011
Resolution: Ballast reports were provided. During annual inspection the ballast transfer records were kept onboard the tug and were not available to the MI.
Deck/Cargo › Holds/Tanks › Coaming
Issued 29 July 2011 Resolved
All hatches needs to be surveyed, some hatches are missing gaskets, some are wasted, and some need to be resurfaced. Repair or replace.
Due 31 October 2011
Resolved 31 October 2011
Resolution: Received ABS report # NY2056377 dated 31OCT2011. Report stated all cargo hatches and ballast hatches were replaced (1-8 P/S cargo tanks & 1-8 P/S ballast tanks) and tested to rule requirements. All were found in satisfactory condition.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 29 July 2011 Resolved
Provide evidence of drill exercises for the VRP.
Due 14 August 2011
Resolved 14 October 2011
Resolution: Documentation was provided for the VRP exercises.
Engineering › Fuel Oil Service System › Tank
Issued 29 July 2011 Resolved
Fuel line for day tank repair or replace.
Due 14 August 2011
Resolved 14 August 2011
Resolution: Fuel fill line was replaced and hydroed at 225 PSI for 30 min. All Sat.
Deck/Cargo › Ballast › Valves
Issued 29 July 2011 Resolved
All valve indicators need to be surveyed, repair or replace in-kind.
Due 31 October 2011
Resolved 31 October 2011
Resolution: Attended vessel, visually inspected all valve indicators. All valve indicators were repaired satisfactory.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 13 January 2009 Resolved
1. Complete no later than 14Feb09: Make transfer procedures compliant with the loading and discharge rates noted in Item #1 of 12Jan09 approval letter.
Action required: 705 - Other - as specified
Due 14 February 2009
Resolved 15 January 2009
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 13 January 2009 Resolved
2. To be completed prior to 14Feb09: Tables and graphs noted in item #4 of the 12Jan09 Approval letter did not match the graphs and tables in the transfer procedures.
Action required: 705 - Other - as specified
Due 14 February 2009
Resolved 15 January 2009
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 13 January 2009 Resolved
3. To be completed prior to 14Feb09: Provide approved Hazardous locations plan for the vessel. ABS Has a record of an approved plan being completed, but their copies are currentlu in INDIA being copied and the local shipyard plas were lost during Katrina. Upon ABS concurance with this I will clear this deficiency.
Action required: 705 - Other - as specified
Due 14 February 2009
Resolved 21 January 2009
Resolution: Received hazardous location plan from ABS.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 13 January 2009 Resolved
All PV Valves located on the cargo tanks must be replaced and or tested and properly tagged.
Action required: 705 - Other - as specified
Due 14 February 2009
Resolved 10 March 2009
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 13 January 2009 Resolved
High velosicty pv valve located on the Vapor header can not be opened manually, make repairs to same.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2009
Resolved 15 January 2009
Resolution: Witnessed satisfacotry operation of high velocity PV valve.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 23 April 2007 Resolved
All cargo piping and cargo transfer hoses must have the annual hydrostatic testing completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2007
Resolved 26 April 2007
Resolution: Received documentation for hydrostatic testing of cargo piping, transfer hoses, relief valves, and cargo pump gauges.
Construction/Loadline › Hull › Longitudinal Frame
Issued 23 April 2007 Resolved
Port #8 DB Tank, Bay 7, SSL #4, 5, & 6 (from the top) must be C/R as discussed.
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 21 June 2007
Construction/Loadline › Hull › Transverse Frame
Issued 23 April 2007 Resolved
C/R #1 & 2 horizontal swash bulkhead as marked IWO side shell.
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 21 June 2007
Construction/Loadline › Hull › Side Shell
Issued 23 April 2007 Resolved
C/R side shell IWO #1 swash bulkhead as marked.
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 21 June 2007
Construction/Loadline › Hull › Side Shell
Issued 23 April 2007 Resolved
C/R sideshell between #2 & 3 horizontal swash bulkhead as marked.
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 21 June 2007
Deck/Cargo › Ballast › Piping
Issued 23 April 2007 Resolved
#7 Stbd DB - make permanent repairs to holes in ballast piping as discussed.
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 21 June 2007
Engineering › Diesel Engine (auxiliary)
Issued 27 May 2003 Resolved
REPLACE OIL PRESSURE SENCING UNITS FOR #2 CARGO PUMP PRIME MOVER AND #1 GENERATOR. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 June 2003
Resolved 12 June 2003
Resolution: Sensors were replaced. Ran both engines. No leaks were noted.
Deck/Cargo › Holds/Tanks
Issued 27 May 2003 Resolved
REPLACE AS ORIGINAL THE SOUNDING TUBE FOR DIESEL FUEL TANK LOCATED ON THE STBD SIDE MAIN DECK. LEGACY COMPONENT DESC: Liquid Level Gaging
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 June 2003
Resolved 12 June 2003
Electrical
Issued 14 March 2001 Resolved
TEST LOW LUBE OIL PRESSURE AND OVERSPEED TRIPS FOR #3 GENERATOR PRIOR TO OPERATION.
Condition: Unknown
Due 14 March 2001
Resolved 14 March 2001
Lifesaving
Issued 14 March 2001 Resolved
PROVIDE A LINE THROWING APPERATUS IAW 46 CFR 199.170.
Condition: Unknown
Due 14 March 2001
Resolved 14 March 2001
Lifesaving
Issued 14 March 2001 Resolved
PROVIDE HYDROSTATIC RELEASE FOR EPIRB IAW 46 CFR 199.510.
Condition: Unknown
Due 14 March 2001
Resolved 14 March 2001
Engineering
Issued 14 March 2001 Resolved
REPAIR/ REPLACE DAMAGED AND FALLEN DOWN CHOKE RING COMBUSITON TILES FOR BOTH FOR AND AFT THERMAL FLUID HEATERS PRIOR TO OPERATION.
Condition: Unknown
Due 14 March 2001
Resolved 14 March 2001
Electrical
Issued 14 March 2001 Resolved
REPAIR LOW LUBE OIL TRIP FOR #2 GENERATOR PRIOR TO OPERATION.
Condition: Unknown
Due 14 March 2001
Resolved 14 March 2001
Navigation
Issued 12 May 2000 Resolved
CORRECT AFT NAVIGATION LIGHTING TO SHOW PROPER CHARACTERISTICS IAW COLREGS.
Condition: Unknown
Due 12 May 2000
Resolved 24 May 2000
Deck/Cargo
Issued 12 May 2000 Resolved
PROVE PROPER OPERATION AND TESTING OF #2 THERMAL FLUID HEATER PRIOR TO USE.
Condition: Unknown
Due 12 May 2000
Resolved 24 May 2000

Casualty record · 6

17 November 2009Routine · role: Involved in a Marine Investigation (non-casualty) · 1 injured · activity 3639677
12 July 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4384887
13 November 2012Routine · role: Involved in a Marine Casualty · activity 4510055
3 March 2016Routine · role: Involved in a Marine Casualty · activity 5826651
7 April 2016Routine · role: Involved in a Marine Casualty · activity 5902146
25 July 2018Routine · role: Involved in a Marine Casualty · activity 6517437
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

B. NO. 215 (2009–2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.