Inspection history · 155
16 April 2025
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8113038
28 June 2024
Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination · MARPOL Annex II Examination · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7925840
6 June 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7929778
31 January 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7858537
26 July 2022
Internal Structural Exam · Administrative Inspection · Examination of Repairs · MARPOL Annex I Examination · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7510959
6 May 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7445236
16 October 2020
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7079998
18 May 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6955379
7 May 2020
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6953985
26 February 2020
In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6916293
6 December 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6869022
7 November 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6851751
17 September 2019
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6814744
3 September 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6805789
18 June 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6718671
8 January 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6606976
28 December 2018
Damage Survey · Administrative Inspection · Permit to Proceed
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6603377
23 August 2018
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6521025
1 August 2018
COI Inspection · Deficiency Check · Drydock Exam · Cargo Tank Internal · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6498028
6 July 2018
Administrative Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6469879
16 May 2018
MARPOL Annex VI Survey · MARPOL Annex I Examination · MARPOL Annex II Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6405708
6 March 2018
Annual Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6367121
5 December 2017
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6318874
28 July 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6223443
14 June 2017
Deficiency Check · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6176781
2 June 2017
Periodic Inspection · MARPOL Annex II Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6161116
30 May 2017
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6160565
11 May 2017
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6143672
11 May 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6333323
28 March 2016
Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination · MARPOL Annex II Examination · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5839718
15 December 2015
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5783598
17 July 2015
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5187449
29 June 2015
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5177913
4 June 2015
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5219182
4 April 2015
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5097631
4 March 2015
Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5074590
22 January 2015
MARPOL Annex VI Survey · MARPOL Annex I Examination · MARPOL Annex II Examination · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5056885
27 January 2014
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4789697
17 January 2014
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4784728
20 December 2013
COI Inspection · MTSA/ISPS Verification · MARPOL Annex II Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4769834
22 November 2013
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4757511
29 October 2013
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4743290
26 October 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4741504
25 October 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4741404
1 October 2012
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4454274
30 March 2012
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4275620
30 March 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4294841
5 March 2012
Internal Structural Exam · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4256766
30 November 2011
Periodic Inspection · MARPOL Annex VI Survey · MARPOL Annex II Examination · MTSA Verification · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4196839
4 October 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4160872
23 June 2011
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4060393
27 August 2010
Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3837593
19 August 2009
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3570700
2 April 2009
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3444838
5 January 2009
Permit to Proceed · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3388544
30 December 2008
Administrative Inspection · Internal Structural Exam · Examination of Repairs · MTSA/ISPS Verification · Permit to Proceed · Cargo Tank Internal · Drydock Exam · COI Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3388573
10 November 2008
Drydock Extension
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3360431
17 April 2008
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3186578
9 April 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3181839
25 March 2008
MARPOL Annex I Examination · MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3170810
17 March 2008
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3166287
13 May 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2928879
8 February 2007
Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2869575
21 November 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2830195
14 November 2006
MARPOL Annex I Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2825251
11 August 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2743878
27 July 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2727401
15 March 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2603053
6 March 2006
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2597276
3 February 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2578894
31 January 2006
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2576887
1 December 2005
MARPOL Annex I Examination · MARPOL Annex II Examination · MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2543860
1 August 2005
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2447314
14 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2309856
10 March 2005
MARPOL Annex I Examination · MARPOL Annex II Examination · MARPOL Annex V Examination · Annual Inspection · MTSA Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2307457
5 January 2005
Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2269369
1 December 2004
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2251531
3 September 2004
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2190492
28 May 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2080683
29 December 2003
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1964829
9 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1962417
9 October 2003
Internal Structural Exam · Hull Examination · MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1924638
30 July 2003
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1861432
10 March 2003
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1755167
10 February 2003
Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1742196
17 October 2002
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1692017
16 October 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1694378
25 July 2002
Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1652136
10 June 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1628829
11 December 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1077224
16 November 2001
MARPOL Annex V Examination · COI Inspection · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1401597
12 April 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 163478
18 March 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 494379
30 January 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1453859
19 December 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 32683
19 December 2000
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1417187
14 October 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 471444
21 July 2000
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1432365
27 April 2000
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 817355
18 February 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 79989
21 January 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1060839
9 December 1999
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 812320
30 November 1999
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1388951
24 November 1999
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1388950
12 June 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 508447
24 May 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 529301
27 January 1999
Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 790180
23 November 1998
Re-Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1465428
8 June 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 474795
7 December 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 455385
29 November 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 524878
20 November 1997
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1109759
13 June 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 453185
9 June 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2219
8 June 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 506211
24 May 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 526546
5 March 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 442071
29 December 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 530729
6 December 1996
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1097675
23 November 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 678095
13 October 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 488583
5 October 1996
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 451675
12 September 1996
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 469772
11 September 1996
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 478921
21 August 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 96669
21 August 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 199848
8 March 1996
Hull Examination · Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1463945
25 February 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 884495
24 February 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 145728
16 February 1996
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1189522
9 February 1996
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1193702
15 January 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 176843
7 December 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 879038
20 November 1995
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1188675
28 October 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 58382
17 October 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1190835
12 October 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 879381
29 September 1995
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 383235
20 September 1995
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 874938
14 September 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 523624
14 September 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1181008
5 August 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 480100
8 May 1995
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 461084
1 April 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 85002
17 January 1995
Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1455317
10 January 1995
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 867905
5 November 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 80938
26 October 1994
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1174527
18 October 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 37973
14 August 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 508987
13 July 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 461756
15 June 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 512562
30 December 1993
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 695649
29 December 1993
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 475808
14 December 1993
Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401782
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 28 June 2024
Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter (0.5 inch) diameter and is at least 25.4 millimeters (1 inch) long. It must be located at the top of the flange face, midway between bolt holes, and in line with the bolt hole pattern. MI found no stud permanently installed on Stbd Fwd Vapor control System Connection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2024
Resolved 4 July 2024
Resolution: New stud was permanently affixed to the manifold.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 June 2024
Resolved
If twist-on type of connectors are used, the connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. MI found twist-on connectors on a battery charger in the generator room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2024
Resolved 4 July 2024
Resolution: Twist-on connectors were removed and wiring was spliced with a crimped connector.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 28 June 2024
Resolved
The construction of each luminaire (lighting fixture) for a non-hazardous location must meet ANSI/UL 1598A, or IEC 60092-306:2009. MI found two aft deck weather lights to be broken and/or full of water within the lenses.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2024
Resolved 4 July 2024
Resolution: Lights were replaced new.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 June 2024
Resolved
An electric apparatus must be designed, constructed, and installed to prevent any person from accidentally contacting energized parts. MI found distribution panels missing blank covering in place of breakers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2024
Resolved 5 July 2024
Resolution: Blanks were placed in the distribution panels, all others were verified to haveblanks in place.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 31 January 2024
Resolved
Each barge equipped with an anchor must be fitted with an operable anchoring system that includes a cable or chain, and a winch or windlass. All components of the system must be in general conformity with the standards issued by a recognized classification society. The anchor must be stowed so that it is ready for immediate use in an emergency. Vessel reported loss of anchor while located in the Mississippi River. Replace anchor and provide report from attending [name withheld] attesting to installation of new anchor and full operability of anchoring system to USCG Marine Inspector prior to departure from Sector New Orleans OCMI zone. 46 CFR 32.15-15 (e)&(f)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2024
Resolution: Received class report from RINA surveyor verifying the satisfactory installation of new anchor.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 10 April 2023
Resolved
A pressure gage shall be installed for each pump discharge, and it shall be located at a point visible with relation to the pump controls. Pressure gage not visible at pump control room.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2023
Resolved 13 April 2023
Resolution: Routed piping correctly to ensure pressure gage is visible at pump controls.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 10 April 2023
Resolved
Metallic expansion joints found to be used for alignment of misaligned pipes. Vessel representative must show manufacturer specs to ensure compliance with installation standards.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2023
Resolved 13 April 2023
Resolution: Cargo piping adjusted to slign correctly with metallic expansion joints. Completed cargo piping pressure test to satisfaction of the Coast Guard.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 10 April 2023
Resolved
A fitted single screen of corrosion-resistant wire of at least 30 by 30 mesh or two fitted screens, both of corrosion resistant wire, of at least 20 by 20 mesh spaced not less than one-half inch or more than 1 1/2 in apart. All cargo tank flame screens are the incorrect mesh material.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2023
Resolved 13 April 2023
Resolution: replaced incorrect mesh with 30 x 30 mesh inserts to the satisfaction of the inspector.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 10 April 2023
Resolved
When a barge is moored and contains no oil but is not gas free: All cargo tank hatches must be clearly marked in not less than three inch lettering "Danger-Keep Out". Danger-Keep Out lettering missing from all hatch covers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2023
Resolved 13 April 2023
Resolution: Danger-Keep Out lettering applied to all hatch covers for cargo tanks.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 10 April 2023
Resolved
Bunker delivery notes missing during IAPP Survey.
Condition: Improper/Lack of Maintenance
Action required: 702 - Prior to embarking on international voyage
Due 10 May 2023
Resolved 13 April 2023
Resolution: Bunker delivery notes available for inspector. All satisfactory
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 April 2023
Resolved
The inspection shall be such as to insure that the vessel, as regards the structure, boilers, and other pressure vessels and their appurtenances, piping, main and auxiliary machinery, electrical installations, life-saving appliances, fire-detecting and extinguishing equipment, pilot boarding equipment, and other equipment is in satisfactory condition and fit for the service for which it is intended. #4 cargo pump prime mover increases RPMs without input.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2023
Resolved 13 April 2023
Resolution: Completed run up of #4 cargo pump prime mover. No discrepancies. Completed emergency shut-off test. Satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 16 October 2020
Resolved
Vessels subject to initial and periodic surveys shall have annual surveys, within 3 months either way of the certificate's anniversary date. The annual surveys shall be made by and prove satisfactory to the assigning and issuing authority prior to executing the required annual endorsements on load line certificates or exemption certificates. The scope shall be as defined in §42.09-40 and such as to ensure that the applicable load line marks are found to be correct for the condition the vessel is then in.
Vessel’s load line certificate was issued by ABS on 09/24/2018 and did not receive its 2019 annual endorsement. Vessel must have an annual survey conducted in accordance with §42.09-40 to verify the certificate’s accuracy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2023
Resolution: RINA issued ILLC 22 MAR 23
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 16 October 2020
Resolved
The equipment shall be maintained to conform with the provisions of this Annex and no changes shall be made in the equipment, systems, fittings, arrangements or material covered by the survey.
The vessel has been surveyed in accordance with regulation 5 of Annex VI and carries an IAPP Certificate stating that it has an approved vapor collection system. The vessel’s vapor collection system has expired safety relief devices and pipe testing records. The vessel’s IAPP Certificate is invalid without a vapor collection system that is maintained and in compliance.
MARPOL Annex VI/5.5
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2023
Resolution: Vessel successfully completed cargo piping hydro test and safety relief valve testing.
14 - Pollution Prevention › 142 - MARPOL Annex II › Other (MARPOL Annex II)
Issued 16 October 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present Convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment.
Due to a lack of maintenance and company support, the vessel has outstanding deficiencies on multiple cargo and ballast operations equipment rendering their compliance with the provisions of their IPPC Certificate obsolete.
MARPOL Annex II/8.3.1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2023
Resolution: Cargo piping adjusted to slign correctly with metallic expansion joints. Completed cargo piping pressure test to satisfaction of the Coast Guard.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 16 October 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present Convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment.
Due to a lack of maintenance and company support, the vessel has expired pipe testing records and outstanding deficiencies on multiple cargo and ballast operations equipment. The vessel’s IOPP Certificate is invalid without maintained cargo piping.
MARPOL Annex I/6.4.1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2023
Resolution: Cargo piping adjusted to slign correctly with metallic expansion joints. Completed cargo piping pressure test to satisfaction of the Coast Guard. Completed IOPP Survey satisfactory.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 16 October 2020
Resolved
Cargo pump relief valves shall be tested at least once each year to determine that they function satisfactorily at the pressure at which they are set to open. The cargo discharge piping of all tank vessels shall be tested at least once each year for tightness, at the maximum working pressure.
Vessel’s cargo pump relief valves and cargo discharge piping are overdue for required annual testing. Vessel must maintain cargo handling equipment.
46 CFR 35.35-70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2023
Resolution: Vessel successfully completed cargo piping hydro test and safety relief valve testing.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 October 2020
Resolved
An inflatable liferaft or inflatable buoyant apparatus must be serviced at a facility specifically approved by the Commandant for the particular brand, and in accordance with servicing procedures meeting the requirements of part 160, subpart 160.151, of this chapter no later than the month and year on its servicing sticker.
Liferafts required by the vessel’s COI expired on 09/05/2020. Vessel must carry liferafts that have been serviced annually.
46 CFR 160.151-57(n)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2023
Resolution: Vessel is no longer permissively manned. Will be unmanned.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 October 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2023
Resolution: Received FCC radio station authorization for vessel.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 October 2020
Resolved
The owner, master, or person-in-charge of a tank vessel must ensure that portable and semi-portable extinguishers are inspected and maintained in accordance with NFPA 10 for annual maintenance and recharging of extinguishers.
All fire protection equipment certificates onboard were expired. Annual servicing must be conducted by a certified fire extinguisher servicing agency.
46 CFR 31.10-18(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2023
Resolution: Received satisfactory report of fire fighting equipment to include fire extinguishers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 October 2020
Resolved
Electric installations on vessels must ensure maintenance of services necessary for safety under normal and emergency conditions and the protection of crew and the vessel from electrical hazards.
Starboard accommodation passageway has broken exterior light switch and missing interior light bulb. Light switch must be replaced and lightbulb must be installed.
46 CFR 111.01-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2023
Resolution: Verified replaced light switch and bulb.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 16 October 2020
Resolved
A cargo tank of the tank vessel connected to a vapor collection system must be equipped with a permanent or portable cargo gauging device that is a closed type as defined in 46 CFR 151.15.10(c) that does not require opening the tank to the atmosphere during cargo transfer and allows the operator to determine the level of liquid in the tank for the full range of liquid levels in the tank.
Vessel’s closed gauging devices are not maintained to meet the complete integrity of cargo containment. Approximately half of the devices have wasted wipers rendering the sight glass inoperable to the operator. All wasted wipers in closed gauging system must be replaced.
46 CFR 39.20-3(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2023
Resolution: Verified repaired wipers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 October 2020
Resolved
The inspection shall be such as to insure that the vessel’s auxiliary machinery equipment is in satisfactory condition and fit for the service for which it is intended.
Rain stops installed at the discharge end of exhaust piping for diesel engines located on the weather deck are seized in the open condition. Protection must be provided as such to prevent the ingress of water into an internal combustion diesel engine.
46 CFR 31.10-15(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2023
Resolution: Verified installation of rain stops.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 7 May 2020
Resolved
rade A, B, or C liquids. Cargo tanks in which Grade A, B, or C liquids are to be transported
shall be fitted with either individual pressure-vacuum relief valves which shall extend to a reasonable
height above the weather deck or shall be fitted with a venting system consisting of branch vent lines
connected to a vent header which shall extend to a reasonable height above the weather deck and be
fitted with a pressure-vacuum relief valve. The vent header system, if fitted, shall be provided with
suitable connections for flushing and draining, and if desired, stop valves may be placed in the
individual branch vent lines: Provided, That each such stop valve is bypassed by a pressure-vacuum
relief valve.
#1 and #2 vacuum tanks relief valves wasted. Replace relief valves.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2020
Resolved 2 March 2023
Resolution: No longer vaccuum tanks on the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2020
Resolved
The respective piping systems installed on ships and barges shall have the necessary
pumps, valves, regulation valves, safety valves, relief valves, flanges, fittings, pressure gages, liquid
level indicators, thermometers, etc., for safe and efficient operation of the vessel.
Starboard ballast pump engine drive shaft sheared off/is missing; Port and Starboard radiators leaking on
ballast pump engines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2020
Resolved 17 March 2023
Resolution: Replaced stbd ballast pump engine drive shaft.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 7 May 2020
Resolved
A tank vessel with a capacity of 250 or more barrels that is carrying oil or hazardous material
as cargo must have— Under or around each loading manifold and each transfer connection point, a fixed container or enclosed deck area that, in all conditions of ship list or trim encountered during the loading
operation, has a capacity of at least: Four barrels if it serves one or more hoses with an inside diameter of 12 inches or more, or one or more loading arms with a nominal pipe size diameter of 12 inches or more;
Port and Starboard cargo manifold containment wasted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2020
Resolved 2 March 2023
Resolution: Verified replaced containment.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 May 2020
Resolved
Vessels contracted for prior to August 22, 2016, must meet the following requirements:
(a) Previously installed extinguishers with extinguishing capacities smaller than as required in
table 34.50-10(a) need not be replaced and may be continued in service so long as they are
maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection.
Starboard side forward flammable locker fixed fire extinguisher wasted. There is a Portable B-40 available within the vicinity of the flammable locker.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2020
Resolved 2 March 2023
Resolution: Received satisfactory report of extinguishers.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2020
Resolved
Location of ground indicators.
Ground indicators must:
(a) Be at the vessel's ship's service generator distribution switchboard for the normal power,
normal lighting, and emergency lighting systems;
(b) Be at the propulsion switchboard for propulsion systems; and (c) Be readily accessible.
Ground detection indicator middle bulb "B Phase" on main distribution panel burned out.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2020
Resolved 17 March 2023
Resolution: Vessel demonstrated successful operation of middle bulb "B Phase" on main distribution panel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2020
Resolved
The respective piping systems installed on ships and barges shall have the necessary pumps, valves, regulation valves, safety valves, relief valves, flanges, fittings, pressure gages, liquid
level indicators, thermometers, etc., for safe and efficient operation of the vessel.
Valve handle broken on starboard midship ballast tank.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2020
Resolved 17 March 2023
Resolution: Replaced valve handle.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2020
Resolved
Each shore connection box must have a bottom entrance
for the shore connection cable. The must provide
protection to the shore connection when the connection
is in use.
Starboard shore connection cover has a hole in the bottom right corner.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2020
Resolved 2 March 2023
Resolution: Verified replaced connection box.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 December 2019
Resolved
On all tank vessels, the construction or conversion of which is started on or after November 10, 1936, the cargo pumps shall be designed and installed to minimize the danger of sparking. Where cargo pump shafts pierce gastight bulkheads, stuffing boxes with readily accessible gastight glands shall be provided. Cargo pump prime movers missing stuffing boxes on four (4) shafts leading to cargo pumps. Prior to conducting cargo discharge operations, vessel must provide satisfactory evidence or install required stuffing boxes to the satisfaction of the attending marine inspector.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 January 2020
Resolved 10 April 2023
Resolution: Inspected new stuffing boxes for cargo pump shafts. All sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 9 December 2019
Resolved
The last 1.0 meter (3.3 feet) of vapor piping upstream of the vessel vapor connection and each end of a vapor hose must be Painted in the sequence of red/yellow/red. The width of the red bands must be 0.1 meter (0.33 foot) and the width of the middle yellow band must be 0.8 meter (2.64 feet) and labeled with the word “VAPOR” painted in black letters at least 50.8 millimeters (2 inches) high. Vapor piping is not painted correctly (i.e., "yellow/red/yellow," with "VAPOR" in white lettering. Painting must be conducted to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2020
Resolved 18 December 2019
Resolution: Vessel properly painted all vapor lines as required.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 6 December 2019
Resolved
The tank overfill alarm required by 46 C.F.R. 39.2007(a) / 46 C.F.R. 39.2009(a)(1), must be identified with the legend “High-level Alarm” in black letters at least 50.8 millimeters (2 inches) high on a white background. Labeling must be completed to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2020
Resolved 18 December 2019
Resolution: Vessel properly lables alarms as required.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 17 September 2019
Resolved
vessel cargo testing certificate was found out of date
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 30 September 2019
Resolution: rcvd report for testing all sat
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 September 2019
Resolved
Each item of survival equipment with an expiration date must be replaced during the annual inspection if the expiration date has passed. The two required liferafts are expired and require an annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 September 2019
Resolved 3 September 2019
Resolution: Vessel replaced two liferafts with servicable rafts.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 3 September 2019
Resolved
Objective evidence discovered during in service inspection revealed the following deficiency: The vessel failed to fully implement the requirements of the SMS as evident by def. #1. An internal audit and correcitve action within three months is required.
ISM/10
ISM Code 10
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 7 November 2019
Resolution: Company Submitted Internal audit and findings. Def has been cleared.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 28 December 2018
Resolved
Owner/operator reported that there is a possible fracture between the #5P and #6P cargo tk bulkhead. Fracture was reported approx 24" up from the #5P tk bottom outboard side. Vessel is directed to make #5P and #6P safe for entry to allow a marine inspector to conduct close up inspection of suspect areas. Inspection must be completed prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2019
Resolution: Noticed that a structural deficiency was open but had been cleared by activity 6606976.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2018
Resolved
(a) The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the following ballast water management methods:
(1) Install and operate a ballast water management system (BWMS) that has been approved by the Coast Guard under 46 CFR part 162
(2) Use only water from a U.S. public water system (PWS), as defined in 40 CFR 141.2, that meets the requirements of 40 CFR parts 141 and 143 as ballast water.
(i) Previously cleaned the ballast tanks (including removing all residual sediments) and not subsequently introduced ambient water; or
(ii) Never introduced ambient water to those tanks and supply lines.
(3) Perform complete ballast water exchange in an area 200 nautical miles from any shore prior to discharging ballast water, unless the vessel is required to employ an approved BWMS per the schedule found in §151.2035(b) of this subpart.
(4) Do not discharge ballast water into waters of the United States.
(5) Discharge to a facility onshore or to another vessel for purposes of treatment.
Operator is on-loading BW in on COPT zone and discharging in another COPT zone.
33 CFR 151.2025
Action required: 10 - Deficiency Rectified
Resolved 21 September 2018
Resolution: Spoke with vessel rep and explained that the vessel could no longer ballast this way.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 6 July 2018
Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society. Raised tank top on cargo tanks 1S, 2S, 4P, 6S, 7P, 7S, 8P, and 8S have several bolts and the surrounding steel that is severely wasted. Renew as original to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2018
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 6 July 2018
Resolved
The valves shall be of substantial construction and first class workmanship and shall be free from imperfections which may affect its serviceability. The flame screen on the P/V on the forward part of the barge was found to have a hole and needs replacing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2018
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 July 2018
Resolved
Each cable entering a box of fitting must be protected from abrasion and must meet the following: (a) each opening through which a conductor enters must be closed. Multiple cable runs along the cargo deck found to have
wasted tubing and packing for alarm panels.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 July 2018
Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and the name of the port and a self-igniting light. Ring lifebuoy located on the bow was found improperly marked with an inoperable light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 September 2018
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 6 July 2018
Resolved
In meeting these requirements the Company should ensure that: .2 any non-conformity is reported, with its possible cause, if known; .3 appropriate corrective action is taken
As noted in deficiency one (1) on 06 Jul 2018 CG-835V (MISLE Activity 6469879) regarding the substandard material condition of the cargo hatches (1P, 2S, 4P, 6S, 7P, 7S, 8P, and 8S), the company failed to meet the requirements of ISM Code 10.2.2 and 10.2.3. Objective evidence in the company's failure to identify additional substandard material condition from crew inspections of the barge cargo area was noted in the lack of the ship's maintenance log entries and failure of taking appropriate corrective actions by the ship's crew or company to address the eight (8) severely wasted cargo hatches identified by the attending Coast Guard Marine Inspectors. Further evidence was noted from the Coast Guard Inspection on 05 Dec 2017 conducted by MSU Texas City. During the 05 Dec 2017 inspection, numerous cargo hatch deficiencies were identified, as noted in MISLE activity 6318874 deficiencies number four (4) and five (5). Deficiencies 4 and 5 were rectified three months later by Sector Miami on 08 MAR 2018 (MISLE
Activity 6367121). During the span of those 3 to 4
months from DEC 2017 to MAR 2018, the ships crew and
company did not reasonable suspect or identified the substandard condition of the remaining cargo hatches as the company only replaced the four cargo hatches (1P, 2P, 5S, and 6P) that were identified from the 05 DEC 2017 Coast Guard inspection. As noted in 10.3 the company should identify equipment and technical
systems of the sudden operational failure of which may
result in hazardous situations. The safety management system should provide for specific measures aimed at
promoting the reliability of such equipment or systems these measures should include the regular testing of standby arrangements and equipment or technical systems that not in continues use. The substandard condition of the wasted cargo hatches clearly presented a hazardous situation on board the B.NO. 240 in not being able to maintain vapor tightness.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2018
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 5 December 2017
Resolved
Each outlet or junction box must be securely attached to its mounting and be affixed so as to maintain its designated degree of protection. Stbd manifold high level alarm connection into junction box is lose due to a missing nut. Replace nut, tighten down and secure to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2017
Resolved 5 December 2017
Resolution: outlet to overfill alarm hubble was repaired and satisfactorily tested. All sat. See attached tech report for details.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 5 December 2017
Resolved
Section 4.5 Part B of the Bouchard Safety Management Manual (2017 edition) prescribes the safe working practices for entry into restricted access spaces. The aft peak port space has been identified as a restricted access space and is regularly accessed for storage. There is no objective evidence to indicate that these safe work practices have been implemented prior to entry. Prior to entry, company is to provide documentation and implementation of safe working practice.
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 23 August 2018
Resolution: Received SMS Analysis and corrective action plan. Cleared deficiency.
Construction/Loadline › Markings › Load Line Mark
Issued 5 December 2017
Resolved
The ring, lines and letters shall be painted in white, yellow on a dark ground or in black on a light ground. They shall also be permanently marked on the sides of the vessels to the satisfaction of the assigning authority. The marks shall be plainly visible and, if necessary, special arrangements shall be made for this purpose. Both port and stbd load lines are faded and hard to read. Repaint in contrasting colors to the satisfaction of the attending Maring Inspector.
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 8 March 2018
Resolution: Already an open deficiency for this item from Setor NOLA on 6/2/2017, with a due date of July 2018. Vessel will be correcting deficiency in dry dock in April.
Construction/Loadline › Structures › Manhole
Issued 5 December 2017
Resolved
Cargo tank venting is to be be carried out in accordance with the provisions within 46 CFR 32.55-25. Cargo tank top hatches 1S, 2P & 2S were venting. Tighten hatches to prevent further venting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2017
Resolved 5 December 2017
Resolution: Crewmember tightened each manhole.
Construction/Loadline › Penetrations › Weld
Issued 5 December 2017
Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and teting of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society. Raised tank top on cargo tanks 1P, 2P, 5S and 6P have several bolts and the surrounding steel that is severely wasted. Renew as original to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 8 March 2018
Resolution: Renewed as original. Cleared deficiency.
Construction/Loadline › Structures › Door
Issued 5 December 2017
Resolved
The boundary bulkheads and decks separating the accommodations and control stations from cargo and machinery spaces and from galleys, main pantries and storerooms other than small service lockers shall be of "A" Class Construction. The foward "A" Class bulkhead for the galley is holed and wasted in way of the door frame. Make repairs to restore continuous boundary to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 8 March 2018
Resolution: Repairs made to continous boundary. Deficiency cleared to satisfaction of RO/RSO.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 5 December 2017
Resolved
The posted fire control plan is no longer legible. Revise and post per the current onboard arrangements to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 8 March 2018
Resolution: Fire plan revised and posted. Cleared deficiency.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 28 July 2017
Resolved
Vessel lost anchor while anchored mm66 LMR. Provide Class report attesting to anchoring arrangement post new anchor installation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2017
Resolution: Received Class report from ABS attesting anchor arrangement with new anchor installed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 June 2017
Resolved
Vessel must have internal structural exam conducted by coast guard at intervals set forth in 46 CFR 31.10-21. Vessel was due for ISE on 07MAR2017. ISE must be conducted prior to departure from New Orleans.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 June 2017
Resolved 5 June 2017
Resolution: Resolved to satisfaction of attending Coast Guard Marine Inspector
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 June 2017
Resolved
Vessel must undergo periodic inspection within 3 months before or after COI's anniversary date. Vessel was due for periodic no later than 30MAR2017. 46CFR31.10-17(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 June 2017
Resolved 2 June 2017
Resolution: Resolved to satisfaction of attending Coast Guard Marine Inspector
Documentation › Certificates/Documents › NLS Certificate
Issued 2 June 2017
Resolved
Vessel cannot carry NLS on an international route until issued valid NLS certificate and cargo record book. MARPOL II/9.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 7 June 2017
Resolution: Survey completed to the saisfaction of attending Marine Inspector.
Documentation › Certificates/Documents › IOPP Certificate
Issued 2 June 2017
Resolved
Vessel cannot carry oil on an international route until valid IOPP certificate is issued.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 7 June 2017
Resolution: Survey completed to the saisfaction of attending Marine Inspector.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 2 June 2017
Resolved
Vessel cannot operate commercially on an international voyage until a valid IAPP is issued. MARPOL VI/2.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 7 June 2017
Resolution: Survey completed to the saisfaction of attending Marine Inspector.
Lifesaving › Lifebuoys › Serviceable
Issued 2 June 2017
Resolved
Vessel is required to have 10 serviceable life rings. 03 life rings have deteriorated wax plugs. Replace. 46CFR199.271
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 5 June 2017
Resolution: Replaced to satisfaction of attending Coast Guard Marine Inspector.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 June 2017
Resolved
Port side, #3 ballast tank, bay #1, fwd intermediate blkhd, where intermediate blkhd meets the side shell approx. 7' of the bottom shell, as indicated on board. Blkhd and longitudinal are distorted beyond acceptable criteria. Crop and renew to good undisturbed metal. Repairs shall be to the satisfaction of attending CG Marine Inspector prior to departure. 46CFR30.01-10
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 June 2017
Resolved 16 June 2017
Construction/Loadline › Penetrations › Weld
Issued 2 June 2017
Resolved
Repair welds as indicated onboard and noted below prior to departure:
See CG-835 05JUN2017.pdf
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 June 2017
Resolved 16 June 2017
Construction/Loadline › Hull › Bottom Plating
Issued 2 June 2017
Resolved
STBD side, bow void at bottom of entry ladder, conduct temporary repairs as authorized by attending Coast Guard Inspector. 46CFR30.01-10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 16 June 2017
Construction/Loadline › Structures › Manhole
Issued 2 June 2017
Resolved
Replace gaskets for all ballast tank deck hatches prior to departure. 46CFR30.01-10
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 June 2017
Resolved 7 June 2017
Resolution: Repairs conducted to the satisfaction of attending Marine Inspector.
Construction/Loadline › Markings › Load Line Mark
Issued 2 June 2017
Resolved
Paint load lines and draft marks at next dry dock. 46CFR42.13-40
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2018
Resolved 12 September 2022
Resolution: Verified Satisfactory Load Line and Draft Marks.
Engineering › Pressure Vessel › Relief Valve
Issued 28 March 2016
Resolved
Failed to provide evidence that pressure vessel relief valve relieves at set pressure less than pressure vessel MAWP. Provide evidence that pressure vessel relief valve relieves at set pressure to satisfaction of OCMI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2016
Resolved 2 June 2017
Resolution: Documentation provided to satisfaction of attending Marine Inspector.
Pollution Prevention/Response › Response Equipment › Containers
Issued 1 October 2012
Resolved
Vessel did not produce any spill kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2013
Documentation › Logs/Records › Logbook (official)
Issued 1 October 2012
Resolved
Vessel rep did not produce proof of Benzene Monitoring Program.
Due 18 January 2013
Resolved 12 January 2013
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 October 2012
Resolved
Navigation lights were taped over and unable to be seen burning brightly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 January 2013
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 1 October 2012
Resolved
Hydrostatic release units were not installed on either liferaft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2013
Lifesaving › Inflatable Liferafts › Markings
Issued 1 October 2012
Resolved
Liferaft launching instructions were not posted.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2013
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 1 October 2012
Resolved
Vessel is missing 02 Type I lifejackets.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2012
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 October 2012
Resolved
Vessel did not have guard over 06 rotating prime movers in pump rooms and generator rooms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2013
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 1 October 2012
Resolved
Vapor Control line was not properly painted.
Condition: Improper Installation
Due 18 January 2013
Resolved 12 January 2013
Lifesaving › Inflatable Liferafts › Not on Board
Issued 1 October 2012
Resolved
Vessel needs a liferaft installed on its forward part due to length requirements.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2013
Lifesaving › Lifebuoys › Quantity
Issued 1 October 2012
Resolved
Vessel has 02 lifebuoys installed but needs 10 total lifebuoys.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2013
Deck/Cargo › Ballast › Vents
Issued 5 March 2012
Resolved
Repair or replace all (16) void space gooseneck hatches. Make temp repair to hatches and permanent repairs set for dry dock in AUG 2012.
Action required: 705 - Other - as specified
Due 15 August 2012
Resolved 12 January 2013
Resolution: Repaired/replaced all void space gooseneck hatches.
Deck/Cargo › Ballast › Vents
Issued 5 March 2012
Resolved
Affect temporary repairs for void space gooseneck hatches to ensure weather tightness.
Action required: 705 - Other - as specified
Due 16 March 2012
Resolved 16 March 2012
Resolution: Witnessed satisfactory temporary repairs to the hatches.
Construction/Loadline › Hull › Hull Plating
Issued 5 March 2012
Resolved
Provide tech report for impress current protection system providing proof that system is operating properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2012
Resolved 20 March 2012
Resolution: Cleared the def. on board the vessel''s paperwork. Did not receive tech. report as vessel needed 4-5 days for proper calibration of system.
Construction/Loadline › Hull › Hull Plating
Issued 5 March 2012
Resolved
During dry-dock inspection, Several washed out welds were discovered on the hull under the forward part of both the S/P Void # 1 as well as the underside of the forward rake. The washed out welds also continue up the turn of the bilges to the side shell and also at the bow. Pick up welds as marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2012
Resolved 20 March 2012
Resolution: Observed satisfactory pick ups welds on bow.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 27 August 2010
Resolved
# 2 STBD wing tank, crop and renew inset at swash bulkhead bay # 3 iwo side shell long 8 - 12
Action required: 705 - Other - as specified
Due 11 October 2010
Resolved 13 October 2010
Resolution: Insert was fitted and completion of repairs was certified by attending ABS Surveyor.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 27 August 2010
Resolved
# 2 STBD wing tank, crop and renew inset at swash bulkhead bay # 6 iwo side shell long 8 - 11.
Action required: 705 - Other - as specified
Due 11 October 2010
Resolved 13 October 2010
Resolution: Insert was fitted and completion of repairs was certified by attending ABS Surveyor.
Communications › Radio Communications › EPIRB
Issued 25 March 2008
Resolved
Provide Registration sticker for EPIRB.
Action required: 705 - Other - as specified
Due 26 April 2008
Resolved 9 April 2008
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 25 March 2008
Resolved
Prove operation of audible alarm for high level alarm. Prior to loading cargo.
Action required: 705 - Other - as specified
Resolved 26 March 2008
Construction/Loadline › Structures › Deck Plating
Issued 31 January 2006
Resolved
Provide an ABS class report attesting to the proper repair and testing of the insert IWO the holed area (due to constant chafing) near the base (at the deck) of the anchor wire hawse pipe.
Due 1 February 2006
Resolved 1 February 2006
Resolution: ABS Report
Engineering › Fuel Oil Service System › Hose
Issued 1 December 2005
Resolved
Replace three fuel hoses on generator engine #1 as discussed.
Condition: Improper/Lack of Maintenance
Due 1 January 2006
Resolved 6 January 2006
Resolution: Three new hoses were placed on generator engine #1
Engineering › Fuel Oil Service System › Hose
Issued 1 December 2005
Resolved
Replace two fuel hoses on generator engine #2 as discussed.
Condition: Improper/Lack of Maintenance
Due 1 January 2006
Resolved 6 January 2006
Resolution: Two new hoses were placed on generator engine #2
Deck/Cargo › Holds/Tanks
Issued 29 December 2003
Resolved
High level and overfill cargo tank alarms were inoperable. LEGACY COMPONENT DESC: Liquid Level Gaging
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 December 2003
Electrical › Electric Supply System (service)
Issued 16 December 2003
Resolved
Ammeter gauge on the main generator swichboard is inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2004
Resolution: Confirmed via email.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 16 December 2003
Resolved
High level and overfill cargo visible alarms are not labeled.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 December 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 16 December 2003
Resolved
Functional test of API plug is needed. LEGACY COMPONENT DESC: Emergency Shut-down
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 December 2003
Deck/Cargo › Vapor Control Systems
Issued 16 December 2003
Resolved
Starboard side aft VCS manifold missing top dead center stud.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 December 2003
Resolved 16 December 2003
Resolution: Corrected upon conclusion of inspection.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 16 December 2003
Resolved
Two of the barges three B-V fire extinguishers have expired hydrostatic testing dates (COI states one B-V is required).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 December 2003
Construction/Loadline › Hull
Issued 30 July 2003
Resolved
NY01: Double side #3 stbd. C/R damage IWO swosh bulkhead #4, Bay 4, SSL #5, #6, #7. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Due 30 September 2003
Resolved 7 November 2003
Resolution: C/R effected area.
Construction/Loadline › Hull
Issued 30 July 2003
Resolved
NY02: Double side #3 stbd. C/R damage to swosh bulkhead IWO SSL #2, #3, #4 from bottom- bay 6 & 7. LEGACY COMPONENT DESC: Hull Plating
Due 30 September 2003
Resolved 7 November 2003
Construction/Loadline › Hull
Issued 30 July 2003
Resolved
NY03: Double side #5 stbd. C/R damage to Bay 6 IWO SSL #4, #5, #6 & swosh bulkhead. LEGACY COMPONENT DESC: Hull Plating
Due 30 September 2003
Resolved 7 November 2003
Pollution Prevention/Response › Response Equipment
Issued 10 February 2003
Resolved
Vessel missing non-sparking tools as required by 33 CFR 155.215 (b)(2). LEGACY COMPONENT DESC: Non-sparking Hand Scoops/Shovels/Buckets
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 10 March 2003
Resolution: Vessel has non-sparking tools as required per 33 CFR 155.215 (b)(2).
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 10 February 2003
Resolved
Smoke detector missing parts and disassembled. LEGACY COMPONENT DESC: Smoke detection
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 10 February 2003
Resolution: Corrected on scene.
Pollution Prevention/Response › Prevention Equipment
Issued 10 February 2003
Resolved
Deck winch leaking hydraulic fluid. LEGACY COMPONENT DESC: Hydraulic leak (Deck winch)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 10 February 2003
Resolution: Corrected onscene
Accommodation/Occupational Safety › Occupational Safety
Issued 10 February 2003
Resolved
Benzene warning signs are painted over and unreadable. LEGACY COMPONENT DESC: Warning signs
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 10 March 2003
Resolution: New Bezene warning signs replaced the old signs.
Electrical › Electric Generation Source (service)
Issued 25 July 2002
Resolved
REPAIR/DEMONSTRATE PROPER OPS OF #2 GENERATOR, TO SAT OF ATTENDING INSPECTOR. PRIOR TO OPERATION. LEGACY COMPONENT DESC: Generator
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 August 2002
Resolved 10 February 2003
Resolution: Genset working properly.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 25 July 2002
Resolved
EXPENDED. LEGACY COMPONENT DESC: Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 August 2002
Resolved 2 August 2002
Electrical
Issued 16 November 2001
Resolved
Isolate/clear full phase AC ground on switchboard.
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Deck/Cargo
Issued 16 November 2001
Resolved
Repair/replace oil pressure gauges on #1 and #2 cargo pump engines.
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Construction/Loadline
Issued 19 December 2000
Resolved
Conduct 2 hr sounding checks of suspect areas; report findings to [name withheld] prior to departing Albany; Maintain 2 hour checks during transit to NYC shipyard. Vsl not to depart SY until satisfactory damage survey conducted by USCG marine inspector and/or ABS surveyor.
Condition: Unknown
Due 21 December 2000
Resolved 21 December 2000
Lifesaving
Issued 19 December 2000
Resolved
Submit form CG-2692 to [name withheld] regarding grounding ivo CIBRO Docks inAlbany, N.Y. within 5 days.
Condition: Unknown
Due 24 December 2000
Resolved 23 January 2001
Electrical
Issued 24 November 1999
Resolved
INSTALL BLANKS ON CIRCUIT BREAKER IN GENERATOR ROOM.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Electrical
Issued 24 November 1999
Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL SHUTDOWN ON #1 GENERATOR.
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Deck/Cargo
Issued 24 November 1999
Resolved
PROVE PROPER OPERATION OF STBD INBOARD CARGO PUMP ENGINE AND REMOTE SHUTDOWN.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Accommodation/Occupational Safety
Issued 24 November 1999
Resolved
SECURE WASHER/DRYER IN STBD CARGO PUMP ENGINE ROOM.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Engineering
Issued 24 November 1999
Resolved
INSTALL FLAME BOWL UNDER RAYCOR FUEL FILTER ON STBD OUTBOARD CARGO PUMP ENGINE.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Electrical
Issued 24 November 1999
Resolved
INSTALL BLANKS ON CIRCUIT BREAKER IN STBD CARGO PUMP ENGINE ROOM.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Construction/Loadline
Issued 24 November 1999
Resolved
REPLACE GASKET ON AFT RAKE HATCH COVER.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Electrical
Issued 24 November 1999
Resolved
PROVE PROPER OPERATION OF OVERSPEED SHUTDOWN AND LOW LUBE OIL SHUTDOWN ON #2 GENERATOR.
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Deck/Cargo
Issued 24 November 1999
Resolved
PROVE PROPER OPERATION OF API PLUG CONNECTION.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Lifesaving
Issued 24 November 1999
Resolved
COVER OPEN PAINT AND SOLVENT CONTAINERS IN PAINT LOCKER.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Accommodation/Occupational Safety
Issued 24 November 1999
Resolved
REPAIR BROKEN LIFELINE STBD AMIDSHIPS.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Lifesaving
Issued 20 November 1997
Resolved
REMOVE AT LEAST 2 STANCHIONS FROM LIFERAFT CRADLE.
Condition: Unknown
Due 20 December 1997
Resolved 2 December 1997
Fire Fighting
Issued 20 November 1997
Resolved
PROVIDE AND PROPERLY STOW 2 ADDITIONAL B II FIRE EXTINGUISHERS ON DECK.
Condition: Unknown
Due 20 December 1997
Resolved 2 December 1997
Lifesaving
Issued 20 November 1997
Resolved
PROPERLY INSTALL REFLECTIVE TAPE ON ALL LIFERINGS.
Condition: Unknown
Due 20 December 1997
Resolved 2 December 1997
Lifesaving
Issued 6 December 1996
Resolved
INSTALL BENZENE WARNING SIGN IN ACCORDANCE WITH 46 CFR 197.
Condition: Unknown
Due 20 December 1996
Resolved 7 February 1997
Lifesaving
Issued 6 December 1996
Resolved
PAINT BENZENE REGULATED AREA IN ACCORDANCE WITH 46 CFR 197.
Condition: Unknown
Due 20 December 1996
Resolved 7 February 1997
Construction/Loadline
Issued 8 March 1996
Resolved
#2 PORT AND STARBOARD VOID SPACES HAVE BUCKLED FRAMES. #2 PORT FRAME #19 ATSIDE SHELL CONNECTION, AND #2 STARBOARD FRAME #18 AT SIDE SHELL CONNECTION.
Condition: Unknown
Due 8 March 1996
Resolved 14 March 1996
Construction/Loadline
Issued 25 February 1996
Resolved
MAKE PERMANENT REPAIRS TO DAMAGE IN STBD WING VOIDS #3 AND #4, FROM FRAME 25 THRU FR 33, IAW A COAST GUARD APPROVED REPAIR PROPOSAL TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 25 February 1996
Resolved 25 February 1996
Electrical
Issued 20 November 1995
Resolved
PROVIDE PROPER OPERATION OF THE OVERSPEED TRIP DEVICES ON TWO GENERATORS.
Condition: Unknown
Due 11 February 1996
Resolved 22 February 1996
Documentation
Issued 20 November 1995
Resolved
PROVIDE COFR WITH PROPER BARGE NAME.
Condition: Unknown
Due 11 February 1996
Resolved 22 February 1996
Deck/Cargo
Issued 14 September 1995
Resolved
DETERMINE CAUSE OF EXCESSIVE LEAKAGE ON CARGO PUMPS # 2, 3, 4. MAKE PERMANENT REPAIRS AND PROVE PROPER OPERATION OF CARGO PUMPS # 2, 3, 4 PRIORTO OPERATING.
Condition: Unknown
Due 16 September 1995
Resolved 15 September 1995
Documentation
Issued 14 September 1995
Resolved
PROVIDE ALL NECESSARY INFORMATION TO PROVE COMPLIANCE WITH THE BENZENE REGULATIONS.
Condition: Unknown
Due 14 September 1995
Resolved 14 September 1995
Construction/Loadline
Issued 17 January 1995
Resolved
SIDE SHELL HOLED. INTERNALS DAMAGED INCLUDING TWISTED SIDE LONGS, BENT GUSSETS, AND BUCKLED BULKHEAD INWAY OF FORWARD RAKE BULKHEAD PORT SIDE. MAKE PERMANENT REPAIRS, IN LIEU OF TEMPORARY WELD REPAIR, TO DAMAGED SIDE SHELL AND INTERNALS.
Condition: Unknown
Due 17 January 1995
Resolved 17 January 1995