Records from 1997 to 2015. Most recent: inspection, 17 October 2015.
Inspection history · 35
17 October 2015
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5744819
8 September 2015
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5233476
30 December 2009
COC-CHEM Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3656818
5 May 2009
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3467925
10 April 2009
MARPOL Annex II Examination · COC-TVE Annual · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3449823
31 July 2008
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3285134
13 May 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3200022
13 May 2008
ISPS I Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3205255
28 December 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3121759
13 December 2007
MARPOL Annex I Examination · MARPOL Annex II Examination · MARPOL Annex V Examination · COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3114728
3 December 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3108970
14 September 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3057508
20 May 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2935193
3 January 2006
ISPS III Exam · COC-TVE Renew
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2560008
16 November 2004
COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2242348
15 November 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2246823
8 April 2003
Security Inspection
Physical examination · USCGC MANTA (WPB 87320) · USCG Heartland District (CGD-H) · Activity 1770595
25 February 2003
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1750158
16 October 2002
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1691131
7 September 2002
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1673999
5 August 2002
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1658308
3 October 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 294359
3 August 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 292531
3 August 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1406991
20 July 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 280123
20 July 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1412150
28 June 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 103706
24 December 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 436054
8 November 1999
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 801945
30 July 1999
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 431170
30 July 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 776932
29 June 1998
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 417479
29 June 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1129034
13 June 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 453185
13 June 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 775264
Fire Fighting › Means of Escape › Doorways
Issued 8 September 2015
Resolved
0999 - Safety - The purpose of this regulation is to provide means of escape so that persons on board can escape safely. The PSCO observed the door handle assembly loose and partially inoperative to the steering gear and engine control room. 74 SOLAS (04) II-2 Reg. 13.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 16 October 2015
Resolution: PSC NOLA received a Corrective Action Plan/Report from Thome Ship Management PTE LTD satisfying the requirement.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 8 September 2015
Resolved
0999 - Safety - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. The PSCO observed several zip ties on smoke detectors and putty around heat sensors in the engine room. 74 SOLAS (04) I/11 (a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 16 October 2015
Resolution: PSC NOLA received a Corrective Action Plan/Report from Thome Ship Management PTE LTD satisfying the requirement.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 8 September 2015
Resolved
0999 - Safety - Each vapor connection flange must have a permanetly attached 0.5 inch diameter stud. Vessels starboard aft flange was missing the required stud. Stud must be installed prior to the utilization of the starboard aft vapor connection. 46 CFR 39.2003 6 (e)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2015
Resolved 16 October 2015
Resolution: PSC NOLA received a Corrective Action Plan/Report from Thome Ship Management PTE LTD satisfying the requirement.
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 8 September 2015
Resolved
0999 - Safety - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed missing lagging on the #1 generators exhaust turbo exhaust. 74 SOLAS (04) i/11 (A)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 September 2015
Resolved 9 September 2015
Resolution: Crew installed exhaust lagging on the turbo charger exhaust piping.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 30 December 2009
Resolved
1899: Vessels vapor control piping at manifold header must be painted banded red/yellow/red. Vessels piping is incorrectly painted yellow on all vapor manifolds. 46CFR39.20(d)(1).
Action required: 15 - Rectify deficiencies by next port
Resolved 30 May 2010
Construction/Loadline › Hull › Hull Plating
Issued 10 April 2009
Resolved
2 insets on port side of hull located approx. 2-4 feet above load waterline in vicinity of frame 91 (vertically beneath forward end of port side gangeway) that may be impacting ships structural members and weakening hull plating. Class surveyor to attend vessel and attest to strucural integrity of hull in way of insets w/in 30 days. SOLAS I-11
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 May 2009
Resolved 22 April 2009
Resolution: From Llyoyd''s Register: Visually examined internal structure of ballast tank 15P in area of 02 indentations in Port Side shell plating at Frame 91 and found no damage to internal structure. Structure is considered satisfactory.
Deck/Cargo › Cargo Heating › General
Issued 13 December 2007
Resolved
Observed several steam leaks on the cargo heating system, including the steam line heating pipe with small hole for the #2 starboard cargo tank and a flange at the main heating supply for the #4 port cargo tank. Several additional leaks were observed and documented by the [name withheld] all steam leaks as notated on deck to the satisfaction of Class prior to return to U.S. Waters.
Action required: 705 - Other - as specified
Due 20 December 2007
Resolved 13 May 2008
Resolution: Upon completion of a joint USCG Security Boarding/ ISPS Exam USCG PSCE received a copy of the Class Document clearing the Cargo Steam Heating Pipe was corrected.
Navigation › Piloting/Steering › Gyro Compass
Issued 7 September 2002
Resolved
Recieved report from the Master of the vessel stating the gyro compass was not operating properly. Vessel requested and received a LOD for entry into San Juan, PR
Condition: Unknown
Due 7 September 2002
Resolved 10 September 2002
Deck/Cargo
Issued 20 July 2000
Resolved
INOPERABLE EYEWASH STATION ON PORT BEAM. TO BE REPAIRED, TO SATISFACTION OF USCG (VIA FAX), PRIOR TO 20AUG00.
Condition: Unknown
Due 20 July 2000
Resolved 9 August 2000
Lifesaving
Issued 30 July 1999
Resolved
Replace expired eyewash.
Condition: Unknown
Due 30 July 1999
Resolved 2 August 1999
Lifesaving
Issued 30 July 1999
Resolved
Provide proper lighting for emergency escape from engine room.
Condition: Unknown
Due 30 July 1999
Resolved 2 August 1999
Lifesaving
Issued 30 July 1999
Resolved
Make painter line attachment correct for port side liferaft.
Condition: Unknown
Due 30 July 1999
Resolved 2 August 1999
Engineering
Issued 30 July 1999
Resolved
Renew the overflow sightglass in the vicinity of I.G.S. control panel in the machinery space.
Condition: Unknown
Due 8 November 1999
Resolved 8 November 1999
Electrical
Issued 30 July 1999
Resolved
Provide proper operation of the emergency diesel generator fuel shut off valve.
Condition: Unknown
Due 30 July 1999
Resolved 2 August 1999