Records from 1984 to 2020. Most recent: inspection, 31 August 2020.
Inspection history · 56
31 August 2020
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7046664
3 August 2020
Administrative Inspection · Examination of Repairs · Hull Examination · Plan Review "T" Boat · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7139159
16 February 2016
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5874149
25 July 2012
Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4411663
8 May 2012
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4306433
30 November 2010
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3902151
18 October 2010
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3873004
15 April 2009
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3453443
15 April 2009
Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3453663
7 October 2008
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3356630
29 May 2008
Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3222049
15 October 2007
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3080814
26 July 2007
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3007688
18 August 2006
Periodic Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2755136
4 October 2005
Periodic Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2508154
18 April 2005
Administrative Inspection
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2336911
22 September 2004
Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2202314
26 September 2003
Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1918959
11 June 2003
Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1820502
29 August 2002
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1668401
26 July 2002
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1653465
12 December 2001
Excursion Permit
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1474704
11 April 2001
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1465025
8 October 2000
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 156698
14 August 2000
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1433710
28 July 1999
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1462003
8 September 1998
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 799531
28 July 1998
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1436109
25 June 1998
Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1472418
30 July 1997
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1117720
30 August 1996
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 936915
7 August 1996
Administrative
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1086964
31 July 1996
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1088837
31 July 1995
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 882176
29 June 1995
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 660525
22 June 1995
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 87848
13 September 1994
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1176660
2 August 1994
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1177242
6 August 1993
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1156829
27 July 1993
Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1155913
25 November 1992
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 827165
26 November 1991
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 940646
6 November 1990
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1217328
3 April 1990
Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1213954
24 October 1989
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1347929
2 December 1988
Administrative
Administrative · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 898930
8 November 1988
Administrative
Administrative · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 891308
2 November 1988
Hull Examination
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 889642
26 October 1988
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1199997
14 April 1988
Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1339909
27 October 1987
COI Inspection · Hull Examination
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1320938
1 October 1986
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1314546
25 October 1985
Credit Drydock
Administrative · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 994171
1 October 1985
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 991794
15 February 1985
Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1285267
2 October 1984
Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 974225
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 18 October 2010
Resolved
Apply draft marks to hull with contrasting color as required by 46 CFR 185.30-3.
Action required: 705 - Other - as specified
Due 6 May 2011
Resolved 31 August 2020
Resolution: Vessel is out of service with no valid COI.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 18 October 2010
Resolved
Apply name and hailing port to hull as required by 46 CFR 185.30-3.
Action required: 705 - Other - as specified
Due 25 October 2010
Resolved 29 November 2010
Resolution: Vessel name and hailing port is displayed on vessels stern.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 18 October 2010
Resolved
Provide updated charts, light list, and coast pilot as required by 46 CFR 185.20-35.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2010
Resolution: Updated Nav Pubs have been placed on board.
Fire Fighting › Firemans Outfit › Axe
Issued 18 October 2010
Resolved
Stencil fire axe with vessel name as required by 46 CFR 181.35-1.
Action required: 705 - Other - as specified
Due 25 October 2010
Resolved 18 October 2010
Resolution: Vessels name on the fire axe is not a requirement. Cleared without prejudice.
Lifesaving › Lifefloat › Painter
Issued 18 October 2010
Resolved
Replace life float painter due to aging as required by 46 CFR 185.30-25.
Action required: 705 - Other - as specified
Due 29 November 2010
Resolved 29 November 2010
Resolution: Life float painter has been replaced with new.
Stability › Watertight Integrity › General
Issued 18 October 2010
Resolved
Repair or replace #3 and #4 hatch cover hinge due to rusting as required by 46 CFR 185.30-25.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 29 November 2010
Resolution: The #3 and #4 hatch cover hinges have been repaired.
Stability › Watertight Integrity › General
Issued 18 October 2010
Resolved
Repair or replace aft #5 safety latch on hatch as required by 46 CFR 185.30-25.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 29 November 2010
Resolution: The aft #5 hatch safety latch has been repaired.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 18 October 2010
Resolved
Repair or replace steering room high level alarm as required by 46 CFR 182.25-5 by prior to operating.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2010
Resolution: The high water level alarm has been repaired.
Engineering › Steering Gear System › Hydraulic Hose
Issued 18 October 2010
Resolved
Repair hydraulic hose leak in steering compartment as required by 46 CFR 182.30.
Action required: 705 - Other - as specified
Due 28 October 2010
Resolved 29 November 2010
Resolution: Steering hydraulic leak has been repaired.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 18 October 2010
Resolved
Repair or replace oil discharge placard in engine room as required by 46 CFR 176.35-25.
Action required: 705 - Other - as specified
Due 25 October 2010
Resolved 31 August 2020
Resolution: A new oil discharge placard has been placed in the engine room.
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 18 October 2010
Resolved
Replace shredded fan belt on MDE as required by 46 CFR 182.20-1.
Action required: 705 - Other - as specified
Due 25 October 2010
Resolved 29 November 2010
Resolution: New alternator belt has been installed.
Stability › Watertight Integrity › General
Issued 18 October 2010
Resolved
Replace ageing gaskets on #2, #3, #4, #5, and #6 hatch covers as required by 46 CFR 185.30-25.
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 7 April 2011
Resolution: New gasket material replaced on the #2, 3, 4,5 and 6 hatch covers.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 18 October 2010
Resolved
Install appropriate bell signaling device as required by 33 CFR 86.
Action required: 705 - Other - as specified
Due 25 October 2010
Resolved 29 November 2010
Resolution: Vessel has the proper size bell on board.
Construction/Loadline › Structures › Deck Plating
Issued 18 October 2010
Resolved
Drill stop and weld 3 inch crack on deck surface at sounding tube #2 void as required by 46 CFR 177.10 by prior to next operating season.
Action required: 705 - Other - as specified
Resolved 29 November 2010
Resolution: The crack has been properly repaired by welding.
Electrical › Lighting (service) › Lighting Fixture
Issued 26 July 2007
Resolved
Provide protective covering for light in engine room I.A.W. 46 CFR 183.410.
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 15 October 2007
Resolution: Protective covering provided.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 26 July 2007
Resolved
Provide protective cover over electrical outlet at engine room entrance I.A.W. 46 CFR 183.210.
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 15 October 2007
Resolution: Protective cover provided.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 26 July 2007
Resolved
Provide protective face plate for electrical outlet under bridge consol I.A.W. 46 CFR 183.210.
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 15 October 2007
Resolution: Protective face plate provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 July 2007
Resolved
Replace protective machinery guard over fire pump drive shaft I.A.W. 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 15 October 2007
Resolution: Protective machinery guard placed over fire pump.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 July 2007
Resolved
Replace chafing gear for electrical wires on main diesel engine I.A.W. 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 15 October 2007
Resolution: Chafing gear replaced.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 July 2007
Resolved
Install captive/locking device for rail door used to recover persons from the water when in open position I.A.W. 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 15 October 2007
Resolution: Captive/locking device installed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 26 July 2007
Resolved
Provide current copy of certificate of documentation I.A.W. 46 CFR 176.404.
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 16 August 2007
Resolution: Current copy of Certificate of Documentation provided.
Construction/Loadline › Hull › Hull Plating
Issued 26 July 2007
Resolved
Crop and renew marked wasted section of the hull, port side, engine room I.A.W. 46 CFR 176.404. Plan must be submitted and approved prior to commencement of work.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2007
Resolution: New hull plate welded in place.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 18 August 2006
Resolved
Crop out and renew deteriorated metal on #1/#2 compartments bulkhead, #2 compartment forward, stbd stanchion, and #3 compartment longitudinal stiffener where marked.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 April 2007
Resolved 13 March 2007
Lifesaving › Lifebuoys › Serviceable
Issued 22 September 2004
Resolved
Replace ring buoy main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2004
Resolved 25 November 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 September 2004
Resolved
Repair engine room bilge alarm audible alarm in pilot house.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 October 2004
Resolved 25 November 2004
Engineering › Lubricating Oil Service System › Gauge
Issued 22 September 2004
Resolved
Replace lube oil sending unit on main diesel engine, oil leak.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 October 2004
Resolved 25 November 2004
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 22 September 2004
Resolved
Repair and make operational all deck hatches, 7 total.
Condition: Improper/Lack of Maintenance
Due 25 October 2004
Resolved 25 November 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 September 2003
Resolved
Re-stencil ring buoys, vsl name.
Due 28 October 2003
Resolved 22 September 2004
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 26 September 2003
Resolved
Re-stencil child life jackets number lower stowage area.
Due 28 October 2003
Resolved 22 September 2004
Fire Fighting › Fire Pumps › Arrangement
Issued 26 September 2003
Resolved
Repair MDE engine driven fire pump guard.
Due 28 October 2003
Resolved 22 September 2004
Engineering › Bilge Water Management System › Not Operational
Issued 26 September 2003
Resolved
Repair high bilge alarm engine room.
Due 28 October 2003
Resolved 22 September 2004
Construction/Loadline › Hull
Issued 11 June 2003
Resolved
Repair pin hole in hull by cropping and renew bottom plating #2 compartment port side two feet from keel. Insert to be 3/8"x18"x18". LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Due 11 July 2003
Resolved 12 June 2003
Resolution: Repairs and pressure test of hull sat.
Engineering › Steering Gear System › Rudder
Issued 11 June 2003
Resolved
Repair weld fracture on rudder skeg.
Due 11 July 2003
Resolved 11 June 2003
Electrical › Lighting (service)
Issued 26 July 2002
Resolved
INSTALL LIGHT FIXTURE GLOBES AND GUARDS THROUGHOUT VESSEL. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 August 2002
Resolved 23 August 2002
Resolution: NEW GLOBES AND GUARDS INSTALLED.
Fire Fighting › Fire Pumps
Issued 26 July 2002
Resolved
TIGHTEN OR RENEW PACKING ON FIRE PUMP. LEGACY COMPONENT DESC: Gland Sealing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2002
Resolved 5 August 2002
Fire Fighting › Fire Hoses
Issued 26 July 2002
Resolved
PROVIDE 50' LENGTH OF 1 1/2" FIRE HOSE FOR FWD FIRE STATION PRIOR TO OPERATING VESSEL. LEGACY COMPONENT DESC: Number
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2002
Resolved 5 August 2002
Resolution: New hoses installed on vsl.
Electrical › Electrical Distribution System (service)
Issued 26 July 2002
Resolved
REMOVE TEMP ELECTRICAL HEATER FROM PILOT HOUSE. LEGACY COMPONENT DESC: Wiring
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 August 2002
Resolved 23 August 2002
Resolution: HEATER REMOVED FROM PILOT HOUSE.
Electrical › Electrical Distribution System (service)
Issued 26 July 2002
Resolved
REMOVE DEAD END ELECTRICAL WIRES FROM UNDER MAIN ENGINE. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 August 2002
Resolved 5 August 2002
Resolution: Dead end electrical wires removed.
Engineering › Bilge Water Management System
Issued 26 July 2002
Resolved
REPLACE WASTED BILGE SUCTION STRAINER IN STEERING SYSTEM SPACE. LEGACY COMPONENT DESC: Strainer
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2002
Resolved 5 August 2002
Resolution: Bilge strainer replaced.
Engineering › Bilge Water Management System
Issued 26 July 2002
Resolved
REPAIR BILGE SUCTION PIPING ELBOW IN #4 COMPARTMENT. LEGACY COMPONENT DESC: Piping
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 August 2002
Resolved 23 August 2002
Resolution: BILGE SUCTION PIPING REPAIRED.
Engineering › Bilge Water Management System
Issued 26 July 2002
Resolved
PROVIDE SEPARATE INDICATION FOR (2) BILGE ALARM INDICATORS. LEGACY COMPONENT DESC: Interface Detector
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 August 2002
Resolved 23 August 2002
Resolution: SEPARATE INDICATORS FOR BILGE ALARMS INSTALLED.
Engineering › Bilge Water Management System
Issued 26 July 2002
Resolved
LABEL BILGE ALARM INDICATORS IN PILOT HOUSE. LEGACY COMPONENT DESC: Interface Detector
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 August 2002
Resolved 23 August 2002
Resolution: BILGE ALARM INDICATORS LABELED IN PILOT HOUSE.
Accommodation/Occupational Safety › Occupational Safety
Issued 26 July 2002
Resolved
RENEW ENGINE ROOM ESCAPE HATCH MARKINGS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 August 2002
Resolved 5 August 2002
Resolution: Engine room escape hatch markings replaced.
Engineering
Issued 26 July 2002
Resolved
MAKE ENGINE ROOM OVERHEAD SOFT PATCH WATER TIGHT.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 August 2002
Resolved 5 August 2002
Resolution: Engine room soft patch resealed.
Engineering › Diesel Engine (auxiliary)
Issued 26 July 2002
Resolved
INSTALL LAGGING ON GENERATOR EXHAUST PIPING IN ENGINE ROOM. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 August 2002
Resolved 23 August 2002
Resolution: NEW LAGGING INSTALLED ON EXHAUST PIPING FOR GENERATOR.
Engineering › Diesel Engine (auxiliary)
Issued 26 July 2002
Resolved
SECURE GENERATOR COOLING SYSTEM PIPING.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 August 2002
Resolved 23 August 2002
Resolution: GENERATOR COOLING SYSTEM PIPING REATTACHED TO FRAME MEMBER.
Engineering
Issued 11 April 2001
Resolved
DOUBLE CLAMP ALL COOLING HOSES IN ENGINE ROOM PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 12 April 2001
Resolved 30 April 2001
Documentation
Issued 11 April 2001
Resolved
POST THE STABILITY LETTER IN THE PILOT HOUSE PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 12 April 2001
Resolved 30 April 2001
Construction/Loadline
Issued 11 April 2001
Resolved
MARK HULL WITH DRAFT AND LOADING MARKS PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 12 April 2001
Resolved 30 April 2001
Electrical
Issued 11 April 2001
Resolved
PROVIDE PORTABLE EMERGENCY LIGHTS AT THE ENTERNACE TO THE ENGINE ROOM AT INTHE PILOT HOUSE.
Condition: Unknown
Due 12 April 2001
Resolved 30 April 2001
Navigation
Issued 11 April 2001
Resolved
PROVIDE A COPY OF THE INLAND NAVIGATION RULES PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 12 April 2001
Resolved 30 April 2001
Lifesaving
Issued 11 April 2001
Resolved
CONDUCT AND LOG A MAN-OVERBOARD, ABANDON SHIP AND FIRE DRILL PRIOR TO CARRYING PASSENGERS AND PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Engineering
Issued 11 April 2001
Resolved
DOUBLE NUT AND TIGHTEN THE SHAFT PACKING GLAND PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 12 April 2001
Resolved 30 April 2001
Fire Fighting
Issued 11 April 2001
Resolved
PROVIDE A 50 FOOT SECTION OF 1.5 INCH FIRE HOSE PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 12 April 2001
Resolved 30 April 2001
Documentation
Issued 11 April 2001
Resolved
PROVIDE A COPY OF USER FEE PAYMENT PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 12 April 2001
Resolved 30 April 2001
Navigation
Issued 11 April 2001
Resolved
PROVE PROPER OPERATION OF THE EMERGENCY TILLER PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 12 April 2001
Resolved 30 April 2001
Documentation
Issued 11 April 2001
Resolved
PROVIDE BRIDGE, TRAINING AND EQUIPMENT INSPECTION LOGS PRIOR TO THE COMPLAINCE DATE.
Condition: Unknown
Due 12 April 2001
Resolved 30 April 2001
Navigation
Issued 11 April 2001
Resolved
REPAIR STARBOARD NAVIGATION LIGHT PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 12 April 2001
Resolved 30 April 2001
Lifesaving
Issued 11 April 2001
Resolved
PROVIDE A HOLDER FOR THE LIFE FLOAT SEA PAINTER PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 12 April 2001
Resolved 30 April 2001
Accommodation/Occupational Safety
Issued 11 April 2001
Resolved
PROVIDE FOR REVIEW AND APPROVAL INSTALLATION OF THE MAIN DECK FORWARD CLOSING GATE PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 12 April 2001
Resolved 30 April 2001
Lifesaving
Issued 14 August 2000
Resolved
REPLACE OUTDATED BURN OINTMENT IN FIRST AID KIT BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 21 August 2000
Resolved 26 September 2000
Fire Fighting
Issued 14 August 2000
Resolved
CONDUCT CREW TRAINING FOR EMERGENCY CONDITIONS AND PROVIDE DOCUMENTATION TOOCMI BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 21 August 2000
Resolved 26 September 2000
Lifesaving
Issued 14 August 2000
Resolved
MAKE CREW AVAILABLE FOR EMERGENCY FIRE AND MAN OVERBOARD DRILLS BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 21 August 2000
Resolved 26 September 2000
Accommodation/Occupational Safety
Issued 14 August 2000
Resolved
LABEL ENGINEROOM ESCAPES "EMERGENCY EXCAPE, KEEP CLEAR" INSIDE AND OUTSIDE THE ENGINEROOM BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 21 August 2000
Resolved 15 August 2000
Engineering
Issued 14 August 2000
Resolved
INSULATE MAIN ENGINE EXHAUST TURBOCHARGER AND FLEX COUPLING BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 21 August 2000
Resolved 26 September 2000
Electrical
Issued 14 August 2000
Resolved
REMMOVE DEAD END WIRING FROM OLD GENERATOR SYSTEM BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 21 August 2000
Resolved 26 September 2000
Construction/Loadline
Issued 14 August 2000
Resolved
REPAINT VESSEL NAME AND HAILING PORT ON STERN BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 21 August 2000
Resolved 26 September 2000
Electrical
Issued 14 August 2000
Resolved
CLEAN AND TIGHTEN TERMINALS ON MAIN BATTERIES BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 21 August 2000
Resolved 26 September 2000
Documentation
Issued 28 July 1999
Resolved
POST STABILITY LETTER PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Lifesaving
Issued 28 July 1999
Resolved
PROVIDE FIRST AID KIT PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Construction/Loadline
Issued 28 July 1999
Resolved
REPAIR LEAK IN BILGE PIPING CONNECTION AT BULKHEAD, INSIDE # 5 COMPARTMENT PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Documentation
Issued 28 July 1999
Resolved
LOG DRILLS, TRAINING AND EQUIPMENT INSPECTION IN BRIDGE LOG PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Navigation
Issued 28 July 1999
Resolved
REPAINT PORT AND STBD NAVIGATION LIGHT SIDE SHIELDS BLACK MATTE, CLEAN LENSES, AND REMOUNT WIRING ON STBD NAVIGATION LIGHT PRIOR TO THE COMPLIANCEDATE.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Documentation
Issued 28 July 1999
Resolved
DEVELOP ANMD POST ON MAIN DECK A PASSENGER SAFETY ORIENTATION CARD AS REQUIRED BY 46 CFR 185.506 PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Lifesaving
Issued 28 July 1999
Resolved
POST LIFEJACKET DONNING PLACARD ON MAIN DECK AND INSIDE DECK HOUSE PRIOR TOTHE COMPLIANCE DATE.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Lifesaving
Issued 28 July 1999
Resolved
REPLACE OR REPAIR LIFERING ON STARBOARD SIDE MAIN DECK PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Lifesaving
Issued 28 July 1999
Resolved
MARK VESSEL NAME ON PILOT HOUSE LIFE RING AND PROVIDE MOUNT FOR WATERLIGHT PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Fire Fighting
Issued 28 July 1998
Resolved
Replace or service hand portable fire extinguisher in passenger compartment.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Fire Fighting
Issued 28 July 1998
Resolved
Replace fire axe on board the vessel.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Lifesaving
Issued 28 July 1998
Resolved
Install retroreflective tape on Ring Life-Buoys.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Lifesaving
Issued 28 July 1998
Resolved
Remove and/or replace nine adult CORK Lifejackets by 01MAR98.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Lifesaving
Issued 31 July 1996
Resolved
Place retro-reflective material on ring buoys.
Condition: Unknown
Due 31 July 1996
Resolved 31 July 1996
Unknown
Issued 31 July 1996
Resolved
Install VHF placard IAW 46 CFR 121.506.
Condition: Unknown
Due 31 July 1996
Resolved 31 July 1996
Construction/Loadline
Issued 2 August 1994
Resolved
Replace flexible pipe in bilge line through void #3 with steel pipe.
Condition: Unknown
Due 2 September 1994
Resolved 16 August 1994
Navigation
Issued 2 August 1994
Resolved
Replace hydraulic hose from engine room to steering compartment with steel pipe.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Fire Fighting
Issued 2 August 1994
Resolved
Provide 1 additional B-II portable fire extinguisher for the engine room, for a total of 6 portable extinguishers on the vessel.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Construction/Loadline
Issued 2 November 1988
Resolved
REPAIR 2" FRACTURE IN BOTTOM PLATE, #3 VOID STARBOARD, BETWEEN FWD BKHD & 1ST TRAN. FR., UNDER OUTBOARD LONG.
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Fire Fighting
Issued 26 October 1988
Resolved
REPLACE VALVE ON FIRE STATION, STARBOARD SIDE
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Lifesaving
Issued 26 October 1988
Resolved
STENCIL LIFE JACKET LOCKERS WITH NUMBER AND SIZE OF LIFE JACKETS INSIDE
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Electrical
Issued 26 October 1988
Resolved
REPLACE MISSING GLOBES AND GUARDS IN PASSENGER LOUNGE.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Electrical
Issued 26 October 1988
Resolved
REPLACE MISSING GLOBES AND GUARDS ON DECK LIGHTS.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Electrical
Issued 26 October 1988
Resolved
PROVIDE GUARDS FOR LIGHTS IN PILOT HOUSE.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Lifesaving
Issued 26 October 1988
Resolved
REPLACE LIFE RING-MAIN DECK PORT SIDE.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Lifesaving
Issued 26 October 1988
Resolved
STENCIL VESSEL NAME ON LIFE RINGS
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Lifesaving
Issued 26 October 1988
Resolved
REPLACE LINE BETWEEN LIFE RING AND FLOAT LIGHT ON PILOT HOUSE DECK.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Fire Fighting
Issued 26 October 1988
Resolved
REPLACE FIRE HOSE, STARBOARD SIDE, MAIN DECK.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Lifesaving
Issued 26 October 1988
Resolved
PROVIDE ONE ADDITIONAL ADULT LIFE JACKET.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988