MAURY USCG vessel records
← All vessels

CHIPPEWA

Built
1962
Last inspected
13 January 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 January 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI6606
Flag
UNITED STATES
Maury page id
psix-44309

Documentation record

Registered dimensions (L × B × D)84.4 ft × 29.8 ft × 5.2 ft
Registered tonnagegross 81 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPAASCH MARINE SERVICE · ERIE, PA, UNITED STATES · built 1962
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMACKINAC ISLAND, MI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 20 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Regulatory (Subpart C or D), Gross Ton
55 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 23 inspections, each with its date, unit and type; 34 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

13 January 2025 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8062866
31 August 2023 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7781540
13 June 2022 COI Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7460367
13 October 2021 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7331620
23 August 2021 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7296041
2 August 2021 Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7289067
17 September 2020 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7062746
3 July 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6997943
1 June 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6965129
5 September 2019 MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6807140
14 November 2018 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6580576
24 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6547436
19 September 2018 MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6544512
17 October 2017 Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6290990
5 September 2017 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6260221
17 July 2017 COI Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6211892
25 May 2017 Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6158333
28 April 2017 Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6148112
13 April 2017 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6123986
25 January 2017 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6077040
25 November 2016 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6050188
11 October 2016 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6022076
29 September 2016 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6016161

Deficiency record · 34

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 June 2022 Resolved
4 adult PFDs rejected, must be replaced.
Action required: 10 - Deficiency Rectified
Due 22 June 2022
Resolved 22 June 2022
Resolution: Replaced same day with new, properly marked PFDs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 June 2022 Resolved
Engine room intake ventilation fan inop, must be reapired/replaced & secured at the breaker, locked/tagged out until completed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 31 August 2023
Resolution: Vessel COI deactivated. Per Inspection Activity 7781540: Once vessel repairs & upgrades are completed to include an inclining experiment an inspection for certification and new full term COI will be issued.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 22 June 2022 Resolved
Engine room deck plates loose (outboard port MDE & #1 genset), not safe for foot traffic, temp hardware installed to make safe. Permanent repairs required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 31 August 2023
Resolution: Vessel COI deactivated. Per Inspection Activity 7781540: Once vessel repairs & upgrades are completed to include an inclining experiment an inspection for certification and new full term COI will be issued.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 June 2022 Resolved
GPS requires update.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 31 August 2023
Resolution: Vessel COI deactivated. Per Inspection Activity 7781540: Once vessel repairs & upgrades are completed to include an inclining experiment an inspection for certification and new full term COI will be issued.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 22 June 2022 Resolved
Main deck sprinkler system newly installed diffuser heads are not compatible with system, must be replaced with acceptable diffusers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 31 August 2023
Resolution: Vessel COI deactivated. Per Inspection Activity 7781540: Once vessel repairs & upgrades are completed to include an inclining experiment an inspection for certification and new full term COI will be issued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 June 2022 Resolved
Pilothouse main engine oil pressure gauges are faulty/inaccurate, must be repaired/replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 31 August 2023
Resolution: Vessel COI deactivated. Per Inspection Activity 7781540: Once vessel repairs & upgrades are completed to include an inclining experiment an inspection for certification and new full term COI will be issued.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 June 2022 Resolved
Rescue davit line is deteriorated, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 31 August 2023
Resolution: Vessel COI deactivated. Per Inspection Activity 7781540: Once vessel repairs & upgrades are completed to include an inclining experiment an inspection for certification and new full term COI will be issued.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 June 2022 Resolved
Main deck fire station shut-off valve leaks excessively, must be repaired/replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 31 August 2023
Resolution: Vessel COI deactivated. Per Inspection Activity 7781540: Once vessel repairs & upgrades are completed to include an inclining experiment an inspection for certification and new full term COI will be issued.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 13 June 2022 Resolved
Forward corner pilothouse windows impeding visibility, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 31 August 2023
Resolution: Vessel COI deactivated. Per Inspection Activity 7781540: Once vessel repairs & upgrades are completed to include an inclining experiment an inspection for certification and new full term COI will be issued.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 June 2022 Resolved
Excessive corrosion sighted in multiple voids and areas of the main deck. Must be de-scaled and made available for close inspection during up-coming hull exam.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2022
Resolved 31 August 2023
Resolution: Vessel COI deactivated. Per Inspection Activity 7781540: Once vessel repairs & upgrades are completed to include an inclining experiment an inspection for certification and new full term COI will be issued.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 2 August 2021 Resolved
5 main deck bench seats are a hazard to passengers, require repair. Make inaccessible to passengers until properly repaired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2021
Resolved 22 June 2022
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 August 2021 Resolved
Vessel is 23 adult PFDs short. corrected prior to completing inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2021
Resolved 2 August 2021
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 2 August 2021 Resolved
5 BA's need refurbishment (paint & retro-reflective tape).
Action required: 705 - Other - as specified
Due 2 November 2021
Resolved 23 August 2021
Resolution: completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 August 2021 Resolved
Stbd MDE has oil leak, exhaust leak and loose exhaust lagging at turbo, repairs required. MDE & genset exhaust blanketing on second deck has deteriorated and come loose, clean the area around the exhaust tubes and re-apply blanketing. Non-approved fuel lines installed on genset, replace with approved fuel line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2021
Resolved 23 August 2021
Resolution: repaired/corrected.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 September 2019 Resolved
Replace missing stern light and adjust Nav Light configuration IAW Inland Navigation Rules. 46 CFR 120.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 1 June 2020
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 September 2019 Resolved
Replace missing flashlight at operating station. 46 CFR 120.430
Action required: 10 - Deficiency Rectified
Due 5 September 2019
Resolved 5 September 2019
Resolution: Corrected
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 September 2019 Resolved
Repair cracks on port and starboard rubrails. 46 CFR 115.802(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 3 July 2020
Resolution: Craxks repaired.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 September 2019 Resolved
Replace exhaust lagging on maindeck. 46 CFR 116.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 3 July 2020
Resolution: Corrected.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 5 September 2019 Resolved
Calibrate port tachometer to function correctly. 46 CFR 119.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2019
Resolved 3 July 2020
Resolution: Removed tach.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 24 September 2018 Resolved
The vessel is currently broadcasting (1) Improper MMSI Number, (2) Improper Call Sign, (3) Zero Draft.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 October 2018
Resolved 15 July 2019
Resolution: Verified information is updated.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 19 September 2018 Resolved
Openings in weather deck must be watertight. Access scuttle to forepeak is not watertight, no gasket or securing devices are provided. Make access scuttle to forepeak watertight prior to operating in 2019 and before 31MAY2019.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2019
Resolved 5 September 2019
Resolution: corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 19 September 2018 Resolved
Openings in weather deck must be watertight. Access hatch to lazarette is not watertight, no gasket or securing devices are provided. Make hatch to lazarette watertight prior to operating in 2019 and before 31MAY2019.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2019
Resolved 5 September 2019
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 September 2018 Resolved
Bilge Suctions must have a strainer with an open area at least 3 times the open are of the suction piping. Suction strainer in void#3 is wasted, must be replaced before 19OCT2018 to satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2018
Resolved 17 January 2019
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 19 September 2018 Resolved
Exposed hazards must be properly protected. Rotating machinery at front of port propulsion engine is exposed. Install proper guard as to prevent entanglement, to the satisfaction of the attending marine inspector, before 19OCT2018.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2018
Resolved 14 November 2018
Resolution: Guards installed around rotating machinery.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 September 2018 Resolved
A pressure gauge is required at the fire pump discharge. The engine-driven fire pump has no pressure guage. Install a pressure gauge in the fire pump discharge piping as to indicate discharge pressure for either fire pumps and demonstrate proper function of same to the satisfaction of the attending marine inspector, before 19OCT2018.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2018
Resolved 14 November 2018
Resolution: Pressure gauge installed in the fire pump discharge piping.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 September 2018 Resolved
EPIRB must automatically float free and activate. Hydrostatic Release Unit is expired and must be replaced, to the satisfaction of the attending marine inspector, prior to operating more than 3 miles from land and before 19OCT2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 October 2018
Resolved 17 January 2019
Resolution: corrected.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 19 September 2018 Resolved
Station Bill must be provided on vessel having more than 4 crewmembers including master. Vessel has only Emergency Instruction Placards. Develop and post Station Bills at the operating station and in crew areas, to the satifaction of the attending marine inspector, and before 19OCT2018.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2018
Resolved 17 January 2019
Resolution: rescinded.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 19 September 2018 Resolved
Penetrations in watertight bulkheads must have a means to make them watertight. Open-ended 2" pipe penetrating aft bulkhead in 4th void space inboard of outboard deck stringer must be made watertight, prior to 19OCT2018 to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2018
Resolved 21 September 2018
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Block
Issued 10 August 2017 Resolved
Repair oil leak from forward ship service generator drive engine and prove proper operation.
Condition: Improper/Lack of Maintenance
Due 10 September 2017
Resolved 5 September 2017
Fire Fighting › Fire Pumps › Pressure
Issued 10 August 2017 Resolved
Replace and demonstrate proper operation of fire pump discharge pressure gauge.
Condition: Improper/Lack of Maintenance
Due 17 August 2017
Resolved 15 August 2017
Construction/Loadline › Structures › Superstructure
Issued 20 June 2017 Resolved
Repair wastage on lower portions of the bulkheads in both heads and stbd head bulwarks forward corner.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 10 August 2017
Construction/Loadline › Hull › Weld
Issued 28 April 2017 Resolved
O/O noticed pinhole in weld and inset stbd side of fuel tank compartment.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 25 May 2017
Resolution: Sighted proper permanent repairs.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 29 September 2016 Resolved
Post emergency procedures at operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 11 October 2016
Resolution: EP's posted in wheelhouse.
Engineering › Steering Gear System › Linkage
Issued 29 September 2016 Resolved
Tighten all steering couplings and gears.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 11 October 2016
Resolution: Witnessed proper operation of steering gears and linkage, all sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.