MAURY USCG vessel records Sign in
← All vessels

PINK LADY II

PINK LADY II is a 1995 passenger vessel (inspected). The Coast Guard has recorded 62 inspections since 1995, most recently in August 2025, along with 88 deficiencies and 3 casualty investigations between 2005 and 2025.

Records from 1995 to 2025. Most recent: inspection, 3 August 2025.

Built
1995
Last inspected
3 August 2025
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCS8945
423806
Flag
UNITED STATES
368138920
Maury page id
psix-423806

Inspections, by type

…with no type recorded10
Years with a record 27 calendar years (1995–2025)
The 62 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)72.0 ft × 21.0 ft × 5.0 ft
Registered tonnagegross 50 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROBERT N FISH · STUART, FL, UNITED STATES · built 1995
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBOOTHBAY HARBOR, ME
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it50 - Simplified, Gross Ton
40 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL5209MMSI 368138920 · active · compulsorily equipped · granted 26 March 2020, expires 26 March 2030
WDF9813MMSI 367509080 · cancelled · compulsorily equipped · granted 8 November 2011, cancelled 25 March 2020 · licensed under a name not among this hull’s recorded names (not shown)
WCS8945MMSI 367030210 · cancelled · voluntarily equipped · granted 5 April 2005, cancelled 20 February 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

STAR OF CORNUCOPIA Passenger (Inspected) · MISLE 468772 · 8 March 2005 · activity 2734728

Inspection history · 62

3 August 2025 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8204399
3 August 2025 Examination of Repairs
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8205468
1 May 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8126973
17 October 2024 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8020248
23 October 2023 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7815281
31 May 2023 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7701268
2 May 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7680930
12 October 2022 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7576517
20 October 2021 Deficiency Check · COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7336548
5 April 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7175882
14 October 2020 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7077558
8 June 2020 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6971012
22 October 2019 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6844713
22 May 2019 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6690904
2 May 2019 Damage Survey
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6676119
18 April 2019 Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6671302
16 October 2018 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6564466
10 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6536824
19 October 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6295103
26 April 2017 Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6133113
19 October 2016 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6000623
20 October 2015 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5231021
16 October 2014 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5006420
4 May 2009 Construction Oversight · Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3467259
16 May 2008 Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3210940
11 April 2008 Internal Structural Exam · Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3181847
19 April 2007 COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2908620
2 October 2006 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2792023
2 June 2006 Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2668339
1 December 2005 Re-Inspection · Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2619127
28 July 2005 Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2442564
22 June 2005 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2398306
8 March 2005 Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2307530
8 March 2005 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2734728
8 November 2004 Deficiency Check · In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2235206
29 June 2004 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2114081
14 May 2003 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1794323
8 May 2003 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1788931
24 April 2002 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1610375
26 July 2001 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1070721
16 July 2001 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1067095
9 May 2001 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1064826
12 June 2000 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1070953
16 May 2000 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1426408
6 August 1999 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1110780
18 May 1999 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1375849
10 May 1999 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 807830
5 May 1999 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1106637
4 May 1999 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1375848
14 December 1998 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 808223
22 September 1998 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 800867
18 June 1998 Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1442714
5 May 1997 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1434636
13 February 1997 Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1102845
2 October 1996 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 178790
3 September 1996 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1251681
7 August 1996 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1084299
1 August 1996 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1088707
2 May 1996 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1463246
9 November 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 879426
26 June 1995 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 875219
16 June 1995 Inclining Experiment · Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 875522

Deficiency record · 88

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 August 2025 Resolved
Vessel hit a ledge damaging screws, shafts and hull (keel). Make repairs to the satisfaction of the CG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2025
Resolved 4 September 2025
Resolution: Proper repairs made.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 23 October 2023 Resolved
Clean battery boxes as needed.
Due 23 November 2023
Resolved 1 May 2025
Resolution: Battery boxes cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2023 Resolved
Provide proper approved fuel hoses for stbd generator.
Due 23 November 2023
Resolved 1 May 2025
Resolution: Fuel lines replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 October 2021 Resolved
Provide means to pump forepeak.
Due 4 November 2021
Resolved 3 November 2021
Resolution: Hand held pump provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 October 2021 Resolved
Steering linkage found loose and not properly mounted to vessel.
Action required: 60 - Rectify deficiencies prior to movement
Due 21 October 2021
Resolved 22 October 2021
Resolution: Steering linkage properly bolted down.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 October 2021 Resolved
Clean dust and oil from genset windings.
Due 4 November 2021
Resolved 28 October 2021
Resolution: Gensets cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 October 2021 Resolved
Amp gauge on distribution panel not working.
Due 4 November 2021
Resolved 20 May 2022
Resolution: Gauge replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 October 2021 Resolved
Extension cord used for string lights. Remove cord. Hardwire if keeping string lights.
Due 4 November 2021
Resolved 20 May 2022
Resolution: Cords removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 October 2021 Resolved
Dead end wires forward of the house. Remove/reconnect as needed.
Due 4 November 2021
Resolved 20 May 2022
Resolution: Wires remived.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 October 2021 Resolved
DSC unable to be tested.
Due 4 November 2021
Resolved 20 May 2022
Resolution: DSC tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 October 2021 Resolved
Vessel needs new coast pilot and light list.
Due 4 November 2021
Resolved 20 May 2022
Resolution: New pubs provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 October 2021 Resolved
Genset does not have double hose clamps on cooling lines.
Due 4 November 2021
Resolved 3 November 2021
Resolution: Engine piping did not have room for double clamps
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 October 2020 Resolved
Put proper length line on ring life buoy light.
Due 14 November 2020
Resolved 21 October 2021
Resolution: Line replaced.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 14 October 2020 Resolved
Stbd side engine room damper not closing completely.
Due 14 November 2020
Resolved 3 November 2021
Resolution: Fire damper tightened up and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 October 2020 Resolved
Hole in portside generator exhaust.
Due 14 November 2020
Resolved 21 October 2021
Resolution: Exhaust repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 October 2020 Resolved
Trice up bonding wires in ER.
Due 14 November 2020
Resolved 21 October 2021
Resolution: Wires triced up.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 October 2020 Resolved
Replace fuel fileter on STBD Generator with approved filter.
Due 14 November 2020
Resolved 21 October 2021
Resolution: Filters replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 October 2020 Resolved
Tighten up loose solenoid wires on port side generator.
Due 14 November 2020
Resolved 21 October 2021
Resolution: Wires corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 October 2020 Resolved
Repair/replace life buoys as needed.
Due 14 November 2020
Resolved 21 October 2021
Resolution: Life buoys replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 14 October 2020 Resolved
Repair/replace life floats as needed.
Due 14 November 2020
Resolved 3 November 2021
Resolution: 03 new lifefloats purchased.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 May 2019 Resolved
Vessel collided with pier due to loss of electrical power to controls. Oerator could not put vessel in reverse. Resolve elec trical issues to the satisfaction of MI and prove proper operation of controls.
Due 15 May 2019
Resolved 15 May 2019
Resolution: Batteries and battery chaarger replaced. Systems tested. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018 Resolved
The vessel is currently broadcasting (1) Improper length, (2) Zero Draft.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 October 2018
Resolved 21 October 2021
Resolution: AIS corrected.
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 May 2008 Resolved
Engine room bilge alarm inoperable
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2008
Resolved 19 May 2008
Resolution: New engine room bilge alarm installed and tested.
Lifesaving › Lifefloat › Markings
Issued 16 May 2008 Resolved
Primary lifesaving markings are faded. Remark with name of vessel primary lifesaving devices.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2008
Resolved 19 May 2008
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 16 May 2008 Resolved
Markings faded. Remark with vessel name
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2008
Resolved 19 May 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 May 2008 Resolved
Provide cover for belts/pulleys exposed on Port Main Engine
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2008
Resolved 19 May 2008
Fire Fighting › Means of Escape › Emergency Lighting
Issued 16 May 2008 Resolved
One portable light onboard, two required. Provide second portable light
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2008
Resolved 19 May 2008
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 April 2007 Resolved
Renew CG approved retroreflective material/tape on 10 child lifejackets and the adult lifejackets as pointed out by CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 7 May 2007
Lifesaving › Lifefloat › Paddle
Issued 19 April 2007 Resolved
Properly attach and mark paddles with vessel name on lifefloats as pointed out by CG Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 7 May 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 April 2007 Resolved
Clean and tighten all battery connections on starting batteries in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 7 May 2007
Engineering › Bilge Water Management System › Interface Detector
Issued 8 November 2004 Resolved
Provide a high bilge level alarm in FWD void IAW 46CFR182.530(b).
Condition: Improper/Lack of Maintenance
Due 8 December 2004
Resolved 22 February 2005
Engineering › Fuel Oil Service System › Hose
Issued 8 November 2004 Resolved
Prior to the carriage of passengers, replace fuel oil lines on both engines as discussed, IAW 46CFR182.455.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Engineering › Bilge Water Management System › Piping
Issued 8 November 2004 Resolved
Prior to the carriage of passengers, replace bilge/fire pump OVBD discharge valve.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 November 2004 Resolved
Prior to the carriage of passengers, conduct underway transfer procedure.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Fire Fighting › Fire Hydrants › Material
Issued 8 November 2004 Resolved
Prior to the carriage of passengers, provide a spanner wrench for each fire station.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 8 November 2004 Resolved
Prior to the carriage of passengers, replace missing engine mount on STBD MDE, AFT mount.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Operations/Management › Passenger Operations › Safety Orientation
Issued 8 November 2004 Resolved
Label upper deck, AFT ladder with the max passenger count of 75.
Condition: Improper/Lack of Maintenance
Due 15 November 2004
Resolved 12 November 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 November 2004 Resolved
Prior to the carriage of passengers, repair all salt water leaks on BMD's exhaust system. INSPECT EXHAUST PIPING ON BOTH MDE'S WHILE UNDER LOAD.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 November 2004 Resolved
Replace battery wing nuts with locking nuts/washers.
Condition: Improper/Lack of Maintenance
Due 15 November 2004
Resolved 12 November 2004
Engineering › Bilge Water Management System › Manifold
Issued 8 November 2004 Resolved
Re-label and post a diagram of the bilge manifold system.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Lifesaving › Lifefloat › Serviceable
Issued 8 November 2004 Resolved
Prior to the carriage of passengers, provide 50% life floats and all associated equipment IAW 46CFR180.130.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Communications › Radio Communications › EPIRB
Issued 8 November 2004 Resolved
Prior to the carriage of passengers, replace hydrostatic release on EPIRB or prove date installed.
Condition: Unknown
Due 8 November 2004
Resolved 12 November 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 8 November 2004 Resolved
Repair electrical wire connections on lights IWO cabin top. Wires going into deck lights, are exposed.
Condition: Improper/Lack of Maintenance
Due 15 November 2004
Resolved 12 November 2004
Documentation › Certificates/Documents › FCC SSL
Issued 8 November 2004 Resolved
Provide original FCC Safety Certificate and Bridge-to-Bridge Certificate.
Condition: Improper/Lack of Maintenance
Due 8 December 2004
Resolved 12 November 2004
Navigation › Piloting/Steering › Marine Charts
Issued 8 November 2004 Resolved
Prior to the carriage of passengers , provide all required charts and nautical publications IAW 46CFR185.20-35.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 November 2004 Resolved
Attach all deck hatches with lanyards/safety chains to deck.
Condition: Improper/Lack of Maintenance
Due 15 November 2004
Resolved 12 November 2004
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 8 November 2004 Resolved
Prior to the carriage of passengers, lock sewage OVBD discharge valve, and keep closed while with-in 3 nm from shore.
Condition: Improper Installation
Due 8 November 2004
Resolved 12 November 2004
Operations/Management › Drills/Instruction › Fire
Issued 8 November 2004 Resolved
Prior to the carriage of passengers, prove all crew members are familure with the FFFE and bilge system. (MASTER ESPECIALLY, AND BOTHE DECK HANDS.)
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Construction/Loadline
Issued 16 July 2001 Resolved
FREE-UP BOTH GENERATOR SEA VALVES
Condition: Unknown
Due 17 July 2001
Resolved 17 July 2001
Engineering
Issued 16 July 2001 Resolved
RENEW AS ORIGINAL PORT MAIN ENGINE FULE OIL HOSE FROM FUEL FILTER TO ENGINEAS POINTED OUT BY MARINE INSPECTOR, DUE TO CHAFFING.
Condition: Unknown
Due 16 July 2001
Resolved 16 July 2001
Electrical
Issued 16 July 2001 Resolved
RENEW BOAT END OF SHORE-TIE CABLE
Condition: Unknown
Due 16 July 2001
Resolved 16 July 2001
Lifesaving › Buoyant Apparatus › Approval
Issued 16 July 2001 Resolved
RENEW PORT B/A HAMMER RELEASE
Condition: Unknown
Due 16 July 2001
Resolved 8 November 2004
Engineering
Issued 16 July 2001 Resolved
PLUG MAIN ENGINE FUEL OIL FILTER DRAIN VALVES
Condition: Unknown
Due 16 July 2001
Resolved 16 July 2001
Lifesaving
Issued 9 May 2001 Resolved
VESSEL IS RESTRICTED TO 80 TOTAL PERSONS PENDING ADDITON OF REQUIRED PRIMARY LIFESAVING EQUIPMENT IAW 46 CFR TABLE 180.200(C) - (67% IBA OR 100%LIFE FLOATS).
Condition: Unknown
Due 16 July 2001
Resolved 24 July 2001
Fire Fighting
Issued 16 May 2000 Resolved
PROVIDE SERVICING REPORT FOR ALL PORTABLE FIRE EXTINGUISHERS PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Lifesaving
Issued 16 May 2000 Resolved
REPLACE RETRO-REFLECTIVE MATERIAL ON LIFERINGS.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Lifesaving
Issued 16 May 2000 Resolved
REPLACE WATERLIGHT BATTERIES.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Electrical
Issued 16 May 2000 Resolved
COVER/PROTECT EXPOSED RELAYS IN BRIDGE.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Lifesaving
Issued 16 May 2000 Resolved
PRIOR TO CARRIAGE OF PASSENGERS: DEMONSTRATE ENGINE OPERATION; TEST FIXED FIREFIGHTING ALARMS; CONDUCT MAN-OVER-BOARD AND FIRE DRILLS; AND, PROVIDE ALCOHOL AND DRUG TESTING CONSORTIUM INFO TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR AND COGNIZANT OCMI.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Fire Fighting
Issued 6 August 1999 Resolved
COMPLETE INSTALLATION AND TESTING OF THE FIXED FIRE EXTINGUSHING SYSTEM.
Condition: Unknown
Due 6 August 1999
Resolved 9 August 1999
Fire Fighting
Issued 10 May 1999 Resolved
AT NEXT CG INSPECTION, EXAMINE INSTALLATION AND TESTING OF G-MSC APPROVED FIXED CO2 FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Fire Fighting
Issued 4 May 1999 Resolved
REPAIR/REPLACE #2 FIRE STATION VALVE HYDRANT ON MAIN DECK AFT ON STARBOARD SIDE AND PROVE PROPER OPERATION PRIOR TO LOADING PASSENGERS.
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Documentation
Issued 4 May 1999 Resolved
PROVIDE PROOF VESSEL MASTER HAS ATTENDED EAP TRAINING (SUPERVISORY)
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Lifesaving
Issued 4 May 1999 Resolved
INSTALL FULL MACHINERY GUARD AROUND DRIVE BELT ON STARBOARD GENERATOR
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Electrical
Issued 4 May 1999 Resolved
TERMINATE DEAD END WIRES ON AFT BULKHEAD OF ENGINE ROOM IN ENCLOSURE OR REMOVE FROM VESSEL
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Documentation
Issued 4 May 1999 Resolved
PROVIDE GARBAGE LOG ENTRIES
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Lifesaving
Issued 18 June 1998 Resolved
Provide non-combustible or metal trash containers on board the vessel.
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Electrical
Issued 18 June 1998 Resolved
Make repairs to salt water leaks to the main generator.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Fire Fighting
Issued 18 June 1998 Resolved
Provide documentation for the inspection of the portable fire extinguishers.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Lifesaving
Issued 18 June 1998 Resolved
Replace 18' lanyards for survival craft with 3/8" ultraviolet lanyards.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Lifesaving
Issued 18 June 1998 Resolved
Replace 3-6' lanyard on ring buoy with ultraviolet lanyard.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Documentation
Issued 18 June 1998 Resolved
Post Stability letter.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Documentation
Issued 18 June 1998 Resolved
Post Certificate of Inspection.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Engineering
Issued 18 June 1998 Resolved
Have Detroit Diesel technicians provide a written vertification on M.D.E.'srepairs and write their comments on testing the vessel forward and astern.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Navigation
Issued 18 June 1998 Resolved
Update charts and publications.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Documentation
Issued 18 June 1998 Resolved
PROVIDE LOGS FOR CREW TRAINING, EMERGENCY DRILLS, AND MONTHLY EPIRB TEST.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Lifesaving
Issued 18 June 1998 Resolved
Provide the hydrostatic release date on the EPIRB.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Documentation
Issued 1 August 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Lifesaving
Issued 1 August 1996 Resolved
PROVIDE 60 FEET OF 3/8 INCH TAG LINE FOR RING BUOY.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Fire Fighting
Issued 1 August 1996 Resolved
PROVIDE 1 ADDITIONAL BII FIRE EXTINGUISHER PRIOR TO THE CARRAGE OF PASSENGERS, CURRENTLY MISSING ONE BII FROM THAT REQUIRED BY COI.
Condition: Unknown
Due 1 August 1996
Resolved 2 August 1996
Lifesaving
Issued 1 August 1996 Resolved
STENCIL VESSEL'S FLARE BOX.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Fire Fighting
Issued 1 August 1996 Resolved
PROVIDE MARINE BRACKETS FOR 3 PORTABLE FIRE EXTINGUISHERS WHICH CURRENTLY HAVE NO BRACKETS.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Electrical
Issued 16 June 1995 Resolved
PROVIDE PROPER ELECTRICAL COVERS THROUGH-OUT VESSEL.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Electrical
Issued 16 June 1995 Resolved
PROPERLY DEAD END ALL LOOSE WIRING THROUGH-OUT VESSEL.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Navigation
Issued 16 June 1995 Resolved
PROVIDE NAV. PUBS AND CHARTS IAW LOCAL [name withheld].
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Navigation
Issued 16 June 1995 Resolved
PROVIDE COMPASS DEVIATION CARD.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Documentation
Issued 16 June 1995 Resolved
PROVIDE FCC SAFETY CERT.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Documentation
Issued 16 June 1995 Resolved
POST COPY OF STABILITY LTR.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995

Casualty record · 3

8 March 2005Routine · role: Involved in a Marine Casualty · activity 2734728
22 May 2019Routine · role: Involved in a Marine Casualty · activity 6690904
3 August 2025Routine · role: Involved in a Marine Casualty · activity 8204399
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record