Records from 1995 to 2025. Most recent: inspection, 3 August 2025.
Inspection history · 62
3 August 2025
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8204399
3 August 2025
Examination of Repairs
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8205468
1 May 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8126973
17 October 2024
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8020248
23 October 2023
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7815281
31 May 2023
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7701268
2 May 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7680930
12 October 2022
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7576517
20 October 2021
Deficiency Check · COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7336548
5 April 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7175882
14 October 2020
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7077558
8 June 2020
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6971012
22 October 2019
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6844713
22 May 2019
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6690904
2 May 2019
Damage Survey
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6676119
18 April 2019
Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6671302
16 October 2018
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6564466
10 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6536824
19 October 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6295103
26 April 2017
Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6133113
19 October 2016
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6000623
20 October 2015
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5231021
16 October 2014
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5006420
4 May 2009
Construction Oversight · Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3467259
16 May 2008
Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3210940
11 April 2008
Internal Structural Exam · Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3181847
19 April 2007
COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2908620
2 October 2006
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2792023
2 June 2006
Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2668339
1 December 2005
Re-Inspection · Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2619127
28 July 2005
Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2442564
22 June 2005
Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2398306
8 March 2005
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2307530
8 March 2005
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2734728
8 November 2004
Deficiency Check · In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2235206
29 June 2004
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2114081
14 May 2003
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1794323
8 May 2003
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1788931
24 April 2002
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1610375
26 July 2001
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1070721
16 July 2001
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1067095
9 May 2001
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1064826
12 June 2000
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1070953
16 May 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1426408
6 August 1999
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1110780
18 May 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1375849
10 May 1999
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 807830
5 May 1999
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1106637
4 May 1999
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1375848
14 December 1998
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 808223
22 September 1998
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 800867
18 June 1998
Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1442714
5 May 1997
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1434636
13 February 1997
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1102845
2 October 1996
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 178790
3 September 1996
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1251681
7 August 1996
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1084299
1 August 1996
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1088707
2 May 1996
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1463246
9 November 1995
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 879426
26 June 1995
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 875219
16 June 1995
Inclining Experiment · Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 875522
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 August 2025
Resolved
Vessel hit a ledge damaging screws, shafts and hull (keel). Make repairs to the satisfaction of the CG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2025
Resolved 4 September 2025
Resolution: Proper repairs made.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 23 October 2023
Resolved
Clean battery boxes as needed.
Due 23 November 2023
Resolved 1 May 2025
Resolution: Battery boxes cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2023
Resolved
Provide proper approved fuel hoses for stbd generator.
Due 23 November 2023
Resolved 1 May 2025
Resolution: Fuel lines replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 October 2021
Resolved
Provide means to pump forepeak.
Due 4 November 2021
Resolved 3 November 2021
Resolution: Hand held pump provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 October 2021
Resolved
Steering linkage found loose and not properly mounted to vessel.
Action required: 60 - Rectify deficiencies prior to movement
Due 21 October 2021
Resolved 22 October 2021
Resolution: Steering linkage properly bolted down.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 October 2021
Resolved
Clean dust and oil from genset windings.
Due 4 November 2021
Resolved 28 October 2021
Resolution: Gensets cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 October 2021
Resolved
Amp gauge on distribution panel not working.
Due 4 November 2021
Resolved 20 May 2022
Resolution: Gauge replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 October 2021
Resolved
Extension cord used for string lights. Remove cord. Hardwire if keeping string lights.
Due 4 November 2021
Resolved 20 May 2022
Resolution: Cords removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 October 2021
Resolved
Dead end wires forward of the house. Remove/reconnect as needed.
Due 4 November 2021
Resolved 20 May 2022
Resolution: Wires remived.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 October 2021
Resolved
DSC unable to be tested.
Due 4 November 2021
Resolved 20 May 2022
Resolution: DSC tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 October 2021
Resolved
Vessel needs new coast pilot and light list.
Due 4 November 2021
Resolved 20 May 2022
Resolution: New pubs provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 October 2021
Resolved
Genset does not have double hose clamps on cooling lines.
Due 4 November 2021
Resolved 3 November 2021
Resolution: Engine piping did not have room for double clamps
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 October 2020
Resolved
Put proper length line on ring life buoy light.
Due 14 November 2020
Resolved 21 October 2021
Resolution: Line replaced.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 14 October 2020
Resolved
Stbd side engine room damper not closing completely.
Due 14 November 2020
Resolved 3 November 2021
Resolution: Fire damper tightened up and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 October 2020
Resolved
Hole in portside generator exhaust.
Due 14 November 2020
Resolved 21 October 2021
Resolution: Exhaust repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 October 2020
Resolved
Trice up bonding wires in ER.
Due 14 November 2020
Resolved 21 October 2021
Resolution: Wires triced up.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 October 2020
Resolved
Replace fuel fileter on STBD Generator with approved filter.
Due 14 November 2020
Resolved 21 October 2021
Resolution: Filters replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 October 2020
Resolved
Tighten up loose solenoid wires on port side generator.
Due 14 November 2020
Resolved 21 October 2021
Resolution: Wires corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 October 2020
Resolved
Repair/replace life buoys as needed.
Due 14 November 2020
Resolved 21 October 2021
Resolution: Life buoys replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 14 October 2020
Resolved
Repair/replace life floats as needed.
Due 14 November 2020
Resolved 3 November 2021
Resolution: 03 new lifefloats purchased.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 May 2019
Resolved
Vessel collided with pier due to loss of electrical power to controls. Oerator could not put vessel in reverse. Resolve elec trical issues to the satisfaction of MI and prove proper operation of controls.
Due 15 May 2019
Resolved 15 May 2019
Resolution: Batteries and battery chaarger replaced. Systems tested. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018
Resolved
The vessel is currently broadcasting (1) Improper length, (2) Zero Draft.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 October 2018
Resolved 21 October 2021
Resolution: AIS corrected.
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 May 2008
Resolved
Engine room bilge alarm inoperable
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2008
Resolved 19 May 2008
Resolution: New engine room bilge alarm installed and tested.
Lifesaving › Lifefloat › Markings
Issued 16 May 2008
Resolved
Primary lifesaving markings are faded. Remark with name of vessel primary lifesaving devices.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2008
Resolved 19 May 2008
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 16 May 2008
Resolved
Markings faded. Remark with vessel name
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2008
Resolved 19 May 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 May 2008
Resolved
Provide cover for belts/pulleys exposed on Port Main Engine
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2008
Resolved 19 May 2008
Fire Fighting › Means of Escape › Emergency Lighting
Issued 16 May 2008
Resolved
One portable light onboard, two required. Provide second portable light
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2008
Resolved 19 May 2008
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 April 2007
Resolved
Renew CG approved retroreflective material/tape on 10 child lifejackets and the adult lifejackets as pointed out by CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 7 May 2007
Lifesaving › Lifefloat › Paddle
Issued 19 April 2007
Resolved
Properly attach and mark paddles with vessel name on lifefloats as pointed out by CG Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 7 May 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 April 2007
Resolved
Clean and tighten all battery connections on starting batteries in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 7 May 2007
Engineering › Bilge Water Management System › Interface Detector
Issued 8 November 2004
Resolved
Provide a high bilge level alarm in FWD void IAW 46CFR182.530(b).
Condition: Improper/Lack of Maintenance
Due 8 December 2004
Resolved 22 February 2005
Engineering › Fuel Oil Service System › Hose
Issued 8 November 2004
Resolved
Prior to the carriage of passengers, replace fuel oil lines on both engines as discussed, IAW 46CFR182.455.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Engineering › Bilge Water Management System › Piping
Issued 8 November 2004
Resolved
Prior to the carriage of passengers, replace bilge/fire pump OVBD discharge valve.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 November 2004
Resolved
Prior to the carriage of passengers, conduct underway transfer procedure.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Fire Fighting › Fire Hydrants › Material
Issued 8 November 2004
Resolved
Prior to the carriage of passengers, provide a spanner wrench for each fire station.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 8 November 2004
Resolved
Prior to the carriage of passengers, replace missing engine mount on STBD MDE, AFT mount.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Operations/Management › Passenger Operations › Safety Orientation
Issued 8 November 2004
Resolved
Label upper deck, AFT ladder with the max passenger count of 75.
Condition: Improper/Lack of Maintenance
Due 15 November 2004
Resolved 12 November 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 November 2004
Resolved
Prior to the carriage of passengers, repair all salt water leaks on BMD's exhaust system. INSPECT EXHAUST PIPING ON BOTH MDE'S WHILE UNDER LOAD.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 November 2004
Resolved
Replace battery wing nuts with locking nuts/washers.
Condition: Improper/Lack of Maintenance
Due 15 November 2004
Resolved 12 November 2004
Engineering › Bilge Water Management System › Manifold
Issued 8 November 2004
Resolved
Re-label and post a diagram of the bilge manifold system.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Lifesaving › Lifefloat › Serviceable
Issued 8 November 2004
Resolved
Prior to the carriage of passengers, provide 50% life floats and all associated equipment IAW 46CFR180.130.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Communications › Radio Communications › EPIRB
Issued 8 November 2004
Resolved
Prior to the carriage of passengers, replace hydrostatic release on EPIRB or prove date installed.
Condition: Unknown
Due 8 November 2004
Resolved 12 November 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 8 November 2004
Resolved
Repair electrical wire connections on lights IWO cabin top. Wires going into deck lights, are exposed.
Condition: Improper/Lack of Maintenance
Due 15 November 2004
Resolved 12 November 2004
Documentation › Certificates/Documents › FCC SSL
Issued 8 November 2004
Resolved
Provide original FCC Safety Certificate and Bridge-to-Bridge Certificate.
Condition: Improper/Lack of Maintenance
Due 8 December 2004
Resolved 12 November 2004
Navigation › Piloting/Steering › Marine Charts
Issued 8 November 2004
Resolved
Prior to the carriage of passengers , provide all required charts and nautical publications IAW 46CFR185.20-35.
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 November 2004
Resolved
Attach all deck hatches with lanyards/safety chains to deck.
Condition: Improper/Lack of Maintenance
Due 15 November 2004
Resolved 12 November 2004
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 8 November 2004
Resolved
Prior to the carriage of passengers, lock sewage OVBD discharge valve, and keep closed while with-in 3 nm from shore.
Condition: Improper Installation
Due 8 November 2004
Resolved 12 November 2004
Operations/Management › Drills/Instruction › Fire
Issued 8 November 2004
Resolved
Prior to the carriage of passengers, prove all crew members are familure with the FFFE and bilge system. (MASTER ESPECIALLY, AND BOTHE DECK HANDS.)
Condition: Improper/Lack of Maintenance
Due 8 November 2004
Resolved 12 November 2004
Construction/Loadline
Issued 16 July 2001
Resolved
FREE-UP BOTH GENERATOR SEA VALVES
Condition: Unknown
Due 17 July 2001
Resolved 17 July 2001
Engineering
Issued 16 July 2001
Resolved
RENEW AS ORIGINAL PORT MAIN ENGINE FULE OIL HOSE FROM FUEL FILTER TO ENGINEAS POINTED OUT BY MARINE INSPECTOR, DUE TO CHAFFING.
Condition: Unknown
Due 16 July 2001
Resolved 16 July 2001
Electrical
Issued 16 July 2001
Resolved
RENEW BOAT END OF SHORE-TIE CABLE
Condition: Unknown
Due 16 July 2001
Resolved 16 July 2001
Lifesaving › Buoyant Apparatus › Approval
Issued 16 July 2001
Resolved
RENEW PORT B/A HAMMER RELEASE
Condition: Unknown
Due 16 July 2001
Resolved 8 November 2004
Engineering
Issued 16 July 2001
Resolved
PLUG MAIN ENGINE FUEL OIL FILTER DRAIN VALVES
Condition: Unknown
Due 16 July 2001
Resolved 16 July 2001
Lifesaving
Issued 9 May 2001
Resolved
VESSEL IS RESTRICTED TO 80 TOTAL PERSONS PENDING ADDITON OF REQUIRED PRIMARY LIFESAVING EQUIPMENT IAW 46 CFR TABLE 180.200(C) - (67% IBA OR 100%LIFE FLOATS).
Condition: Unknown
Due 16 July 2001
Resolved 24 July 2001
Fire Fighting
Issued 16 May 2000
Resolved
PROVIDE SERVICING REPORT FOR ALL PORTABLE FIRE EXTINGUISHERS PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Lifesaving
Issued 16 May 2000
Resolved
REPLACE RETRO-REFLECTIVE MATERIAL ON LIFERINGS.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Lifesaving
Issued 16 May 2000
Resolved
REPLACE WATERLIGHT BATTERIES.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Electrical
Issued 16 May 2000
Resolved
COVER/PROTECT EXPOSED RELAYS IN BRIDGE.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Lifesaving
Issued 16 May 2000
Resolved
PRIOR TO CARRIAGE OF PASSENGERS: DEMONSTRATE ENGINE OPERATION; TEST FIXED FIREFIGHTING ALARMS; CONDUCT MAN-OVER-BOARD AND FIRE DRILLS; AND, PROVIDE ALCOHOL AND DRUG TESTING CONSORTIUM INFO TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR AND COGNIZANT OCMI.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Fire Fighting
Issued 6 August 1999
Resolved
COMPLETE INSTALLATION AND TESTING OF THE FIXED FIRE EXTINGUSHING SYSTEM.
Condition: Unknown
Due 6 August 1999
Resolved 9 August 1999
Fire Fighting
Issued 10 May 1999
Resolved
AT NEXT CG INSPECTION, EXAMINE INSTALLATION AND TESTING OF G-MSC APPROVED FIXED CO2 FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Fire Fighting
Issued 4 May 1999
Resolved
REPAIR/REPLACE #2 FIRE STATION VALVE HYDRANT ON MAIN DECK AFT ON STARBOARD SIDE AND PROVE PROPER OPERATION PRIOR TO LOADING PASSENGERS.
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Documentation
Issued 4 May 1999
Resolved
PROVIDE PROOF VESSEL MASTER HAS ATTENDED EAP TRAINING (SUPERVISORY)
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Lifesaving
Issued 4 May 1999
Resolved
INSTALL FULL MACHINERY GUARD AROUND DRIVE BELT ON STARBOARD GENERATOR
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Electrical
Issued 4 May 1999
Resolved
TERMINATE DEAD END WIRES ON AFT BULKHEAD OF ENGINE ROOM IN ENCLOSURE OR REMOVE FROM VESSEL
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Documentation
Issued 4 May 1999
Resolved
PROVIDE GARBAGE LOG ENTRIES
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Lifesaving
Issued 18 June 1998
Resolved
Provide non-combustible or metal trash containers on board the vessel.
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Electrical
Issued 18 June 1998
Resolved
Make repairs to salt water leaks to the main generator.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Fire Fighting
Issued 18 June 1998
Resolved
Provide documentation for the inspection of the portable fire extinguishers.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Lifesaving
Issued 18 June 1998
Resolved
Replace 18' lanyards for survival craft with 3/8" ultraviolet lanyards.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Lifesaving
Issued 18 June 1998
Resolved
Replace 3-6' lanyard on ring buoy with ultraviolet lanyard.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Documentation
Issued 18 June 1998
Resolved
Post Stability letter.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Documentation
Issued 18 June 1998
Resolved
Post Certificate of Inspection.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Engineering
Issued 18 June 1998
Resolved
Have Detroit Diesel technicians provide a written vertification on M.D.E.'srepairs and write their comments on testing the vessel forward and astern.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Navigation
Issued 18 June 1998
Resolved
Update charts and publications.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Documentation
Issued 18 June 1998
Resolved
PROVIDE LOGS FOR CREW TRAINING, EMERGENCY DRILLS, AND MONTHLY EPIRB TEST.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Lifesaving
Issued 18 June 1998
Resolved
Provide the hydrostatic release date on the EPIRB.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Documentation
Issued 1 August 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Lifesaving
Issued 1 August 1996
Resolved
PROVIDE 60 FEET OF 3/8 INCH TAG LINE FOR RING BUOY.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Fire Fighting
Issued 1 August 1996
Resolved
PROVIDE 1 ADDITIONAL BII FIRE EXTINGUISHER PRIOR TO THE CARRAGE OF PASSENGERS, CURRENTLY MISSING ONE BII FROM THAT REQUIRED BY COI.
Condition: Unknown
Due 1 August 1996
Resolved 2 August 1996
Lifesaving
Issued 1 August 1996
Resolved
STENCIL VESSEL'S FLARE BOX.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Fire Fighting
Issued 1 August 1996
Resolved
PROVIDE MARINE BRACKETS FOR 3 PORTABLE FIRE EXTINGUISHERS WHICH CURRENTLY HAVE NO BRACKETS.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Electrical
Issued 16 June 1995
Resolved
PROVIDE PROPER ELECTRICAL COVERS THROUGH-OUT VESSEL.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Electrical
Issued 16 June 1995
Resolved
PROPERLY DEAD END ALL LOOSE WIRING THROUGH-OUT VESSEL.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Navigation
Issued 16 June 1995
Resolved
PROVIDE NAV. PUBS AND CHARTS IAW LOCAL [name withheld].
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Navigation
Issued 16 June 1995
Resolved
PROVIDE COMPASS DEVIATION CARD.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Documentation
Issued 16 June 1995
Resolved
PROVIDE FCC SAFETY CERT.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Documentation
Issued 16 June 1995
Resolved
POST COPY OF STABILITY LTR.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995