MAURY USCG vessel records Sign in
← All vessels

RANGER 85

RANGER 85 is a 1944 passenger vessel (inspected). The Coast Guard has recorded 90 inspections since 1985, most recently in August 2026, along with 131 deficiencies, 2 operational controls and 1 casualty investigation in 2013.

Records from 1985 to 2026. Most recent: inspection, 13 August 2026.

Built
1944
Last inspected
13 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ3240
Flag
UNITED STATES
367044250
Maury page id
psix-42469

Inspections, by type

…with no type recorded6
Years with a record 39 calendar years (1985–2026)
The 90 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)82.5 ft × 20.3 ft × 10.1 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFELLOWS AND STEWART INC · TERMINAL ISLAND, CA, UNITED STATES · built 1944
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 11 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM7790MMSI 367044250 · active · compulsorily equipped · granted 4 February 2022, expires 4 February 2032
WDJ3240MMSI 367044250 · cancelled · compulsorily equipped · granted 22 December 2016, cancelled 27 January 2022
WDC5643MMSI 367044250 · expired · compulsorily equipped · granted 24 May 2005, cancelled 25 July 2015
WB8701MMSI not assigned · expired · compulsorily equipped · granted 16 February 1994, cancelled 25 April 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CRYSTALINER Commercial Fishing Vessel · MISLE 201394 · 19 May 2014 · activity 4947541CORAL SEA Passenger (Inspected) · MISLE 44041 · 24 August 2006 · activity 2758623

Inspection history · 90

13 August 2026 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8463774
2 April 2025 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8104215
26 November 2024 Administrative Inspection · In-Service Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8039726
10 September 2024 Damage Survey · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8002172
5 April 2024 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7890572
27 March 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7883634
22 December 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7841822
9 March 2023 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7638397
28 December 2022 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7613963
28 November 2022 Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7597964
11 November 2022 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7589479
6 December 2021 Deficiency Check · Damage Survey · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7362073
2 September 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7302412
23 July 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7254151
11 February 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7135165
30 November 2020 Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7098748
11 March 2020 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6916084
10 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6834198
11 January 2019 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6604975
4 December 2018 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6591427
13 February 2018 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6352713
29 November 2017 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6315080
21 December 2016 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6061122
1 December 2016 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6048884
25 May 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5884664
24 June 2014 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4898159
19 May 2014 Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4862792
19 May 2014 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4947541
28 February 2012 DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4245173
19 January 2011 Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3928993
2 February 2010 Internal Structural Exam · Drydock Extension
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3674133
1 May 2008 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3195948
22 February 2008 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3151752
18 January 2008 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3132726
26 October 2007 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3087809
12 January 2007 COI Inspection · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2854688
24 August 2006 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2758623
21 April 2006 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2630260
3 June 2005 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2383020
27 April 2005 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2344838
18 February 2005 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2295400
27 May 2004 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2079793
4 December 2003 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1959508
20 August 2003 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1881787
16 May 2003 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1804198
29 April 2003 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1783177
11 March 2002 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1493237
20 June 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1467302
26 February 2001 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1058921
31 October 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1408618
24 October 2000 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1365999
11 July 2000 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 819657
21 June 2000 Deficiency Check · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1412134
16 March 1999 COI Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1441469
15 March 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 788715
20 October 1998 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 806822
27 May 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1381253
29 April 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1388525
13 May 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1441223
1 October 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1439782
13 March 1996 COI Inspection · Drydock Extension
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1363537
30 March 1995 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1144961
15 March 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1177069
20 October 1994 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 862941
20 September 1994 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1180015
1 April 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 858927
16 March 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 854392
1 June 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 840829
28 May 1993 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 839421
17 April 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 21247
18 March 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1149915
24 March 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1254978
19 March 1992 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1011046
14 December 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 948284
21 March 1991 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1219324
23 January 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 904817
12 December 1990 Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 931261
4 June 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 908436
6 April 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1225607
22 March 1990 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1233808
30 June 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 897458
22 June 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1205817
22 March 1989 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1209306
26 August 1988 Excursion Permit
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1346703
24 March 1988 Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1298548
18 March 1987 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1017523
3 March 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1007271
27 February 1986 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1303672
13 February 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 994473
8 February 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 979105

Deficiency record · 131

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 September 2024 Resolved
Vessel rep reported to SSD that the vessel impacted a rouge wave and caused damage to the stbd forward Bulwark. No water ingress was reported, the vessel ended the voyage and safely returned to San Diego. Verbal no sail was issued to vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2024
Resolution: Vessel made temporary repairs as approved by Sector San Diego.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 March 2024 Resolved
On vessels described by 46 CFR 175.110(d) of this chapter, a passenger safety bill must be posted by the master in each cabin or stateroom, and in passenger accommodation spaces. Vessel did not have the passenger safety bill posted in passenger accommodation spaces. Post passenger safety bill to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 3 April 2024
Resolution: Vessel posted Passenger Safety Bill.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 March 2024 Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: (1) Spaces storing carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.”. (2)Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” The reference to wintergreen scent may be omitted for carbon dioxide systems not required to have odorizing units and not equipped with such units. Vessel was missing required CO2 warning signs. Install CO2 warning signs for aft compartment and machinery space entrance to satisfaction of attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 3 April 2024
Resolution: Vessel posted CO2 warning signs outside of machinery space and CO2 storage room.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 March 2023 Resolved
Emergency egress training for each member of the crew, to occur for all members of the crew - (i) At least monthly while such members are employed on board the vessels; and (ii) Each time a crew member joins the crew of such vessel. Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information. (1) Date of the training; and (2) General description of the training topics. Egress training records were not available. Conduct and log monthly egress training.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 27 March 2023
Resolution: Vessel provided log of training and drill.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2023 Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. An electrical receptacle was found behind the forward berthing stairs unmounted and hanging by the cables. Properly mount electrical receptacle and install cable supports.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 31 March 2023
Resolution: Vessel re-mounted electrical receptical.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 December 2022 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel did not install an interconnected fire detection system by 27DEC2022. Vessel is restricted to a LIMITED COASTWISE route and is prohibited from allowing passengers to utilize overnight accomodations until it's compliance with the interconnected fire detection requirements of 46 CFR 181.405 have been verified by a USCG marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 31 March 2023
Resolution: Vessel installed interconnected fire detection and roving watch monitoring devices which were satisfactorily tested.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 28 November 2022 Resolved
All passenger accommodations must be arranged and equipped to provide for the safety of the passengers in consideration of the route, modes of operation, and speed of the vessel. The deck in the forward passenger bunk room was found to be constructed of general plywood and with areas of severe delamination, warping and soft areas due to chronic moisture damage. Owner plans to replace after dry dock but prior to using the space for passenger accomodation. Replace floor to the satisfaction of the attending marine inspector prior to using for passengers but no later than 01APR2023.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 April 2023
Resolved 9 March 2023
Resolution: Vessel replaced decking.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 November 2022 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended in this section. Portable 2-A fire extignuisher located in the forward passenger berthing area was found with a depleted charge. Service or replace fire extinguisher.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2022
Resolved 28 November 2022
Resolution: Vessel had fire extinguisher serviced.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 November 2022 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. One deckhand had taken his preemployment test but had not received results at the time of inspection. Vessel was manned above the minimum required by the COI. Provide documentation of negative test prior to employment in a safety sensitive position.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2022
Resolved 28 November 2022
Resolution: Vessel provided updated covered crew list showing full compliance for the identified crew member.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 January 2022 Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. The carbon dioxide fixed fire suppression system activation pressure switch did not shut down either generator located in the engine room. Install and demonstrate operation of engine shut downs.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 5 April 2022
Resolution: Vessel installed and tested engine shut downs.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 12 January 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2022
Resolved 25 February 2022
Resolution: Vessel provided current FCC certificates.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 12 January 2022 Resolved
Except when in the judgment of the cognizant OCMI the operation of a vessel does not present one of the hazards listed, the emergency instruction placard should contain at least the applicable portions of the “Emergency Instructions” listed in § 185.512. The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Vessel's emergency instructions were not vessel specific. Provide vessel specific emergency instructions.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2022
Resolved 28 January 2022
Resolution: Vessel provided revised emergency instructions.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 January 2022 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Records of tests and inspections required by 46 CFR 176.810(b) were not available. Provide records.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2022
Resolved 18 February 2022
Resolution: The vessel provided records of servicing.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 January 2022 Resolved
The Rules concerning shapes shall be complied with by day. The lights and shapes specified in these Rules shall comply with the provisions of Annex I of these Rules (33 CFR part 84). Vessel was not carrying day shapes. Provide day shapes.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2022
Resolved 28 January 2022
Resolution: Vessel provided day shapes.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 January 2022 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly portable extinguisher inspections records not available. Conduct and record inspections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 28 January 2022
Resolution: Vessel provided records of inspections.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 January 2022 Resolved
Fire, abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Drill records only contained the date and general type of drill (fire, MOB, abandon ship). Conduct and log drills to include the above information.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 28 January 2022
Resolution: Vessel provided acceptable logs showing completion of drills.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 23 July 2021 Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. All vessels with overnight accommodations must be equipped with a general alarm system. The public address system required by §184.610 of this chapter may be used to sound the general alarm signal. Vessel's Public Address and General Alarm system was not sufficiently audible during normal operating conditions in the passenger bunk spaces. Demonstrate operation of Public Address and General Alarm of adequate volume in all accommodation spaces.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 12 August 2021
Resolution: Vessel installed additional public address speakers and demonstrated operation and volume via video.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 July 2021 Resolved
Each ring buoy on a vessel mus be approved in accordance with §160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Port forward ring buoy was found deteriorated and worn. Provide ring buoy meeting specifications of 46 CFR 160.050.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 5 August 2021
Resolution: Vessel provided pictures of replacement ring life buoy installed on vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 July 2021 Resolved
On a vessel on a voyage of more than 24 hours duration, passengers shall be requested to don life jackets and go to the appropriate embarkation station during the safety orientation. If only a small number of passengers embark at a port after the original muster has been held, these passengers must be given the passenger safety orientation required by paragraphs (a) or (b) of this section if another muster is not held. Vessel did not require passengers to don life jackets during the safety orientation for a three day voyage. After discussion between inspector and vessel master, passengers donned life jackets and deficiency was corrected.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 23 July 2021
Resolution: Vessel required donning after notification by attending inspector.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 11 February 2021 Resolved
Emergency instructions missing instructions for man overboard and rough weather. Provide additional instructions.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2021
Resolved 23 February 2021
Resolution: Vessel updated emergency instructions to include all scenarios required by regulation.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 11 February 2021 Resolved
Aft crew bunk room missing speaker for public address and general alarm. Provide speaker.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2021
Resolved 23 February 2021
Resolution: Vessel installed additional public address/GA speaker in crew berthing and demonstrated operation.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 March 2020 Resolved
Provide current and complete first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 April 2020
Resolution: New first aid kit provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 March 2020 Resolved
Provide fire hose nozzle capable of straight and wide spray.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 April 2020
Resolution: Fire nozzles replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 March 2020 Resolved
Provide spanner wrenches at all fire stations.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 April 2020
Resolution: Spanner wrenches provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2020 Resolved
Remove permanent extension cord powering bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 April 2020
Resolution: Pump rewired correctly.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 11 March 2020 Resolved
Provide plan to replace mattresses or demonstrate compliance with flammability standards.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 April 2020
Resolution: Recieved plan for mattress change out and proof of flammability standards.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2020 Resolved
Unground outlets found throughout Demonstrate proper grounding of outlets. Due by the end of next drydock.
Action required: 705 - Other - as specified
Resolved 30 December 2020
Resolution: Vessel repaired un-grounded outlets and replaced old outlets not making ground connection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2020 Resolved
Provide dead end covers on distribution panel in pilot house.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 April 2020
Resolution: Dead end covers installed.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 March 2020 Resolved
Provide log showing fire, MOB, abandon ship drills as well as epirb & fire ext. inspections.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2020
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 10 October 2019 Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously.
Action required: 10 - Deficiency Rectified
Due 10 October 2019
Resolved 10 October 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 October 2019 Resolved
Vessel required to have the appropriate number of independent modular smoke detection and alarm units in accommodation spaces that are in compliance with UL 217. Must install units in closed berthing spaces amidships of vessel to satisfaction of Coast Guard Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2019
Resolved 11 March 2020
Resolution: Vessel has the required detectors installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 October 2019 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from passenger and crew accommodation spaces below the main deck. Must install emergency lighting in forward sections of port and starboard fwd berthing spaces to satisfaction of CG Marine Inspections.
Action required: 705 - Other - as specified
Due 10 January 2020
Resolved 11 March 2020
Resolution: Emergency lighting installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 October 2019 Resolved
All major appliances on board vessels must be hard wired to the outlet. Freezer in aft accommodation space was plugged into an extension cord. Must rectify to satisfaction of CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2019
Resolved 4 November 2019
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 13 February 2018 Resolved
Provide pre-employment test results for crew member prior to working on board with PAX.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 21 February 2018
Resolution: Crew member decided not to work for the vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 February 2018 Resolved
Hard wire freezer in aft space or provide an outlet so that extention cords are not used.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 February 2018
Resolved 13 February 2018
Resolution: Freezer moved to use existing outlet.
Construction/Loadline › Hull › Transverse Frame
Issued 29 November 2017 Resolved
Repair frames in the bow area as indicated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 10 January 2018
Resolution: All frames in the bow area we fixed as indicated.
Construction/Loadline › Hull › Hull Plating
Issued 21 December 2016 Resolved
Due to water ingress at port chine just aft of the collision bulkhead; open area up for further inspection, make proper repairs, and complete a post repair sea-trial prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 December 2016
Resolved 27 December 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 December 2016 Resolved
Prove proper operation of the port nav light; restricted to daylight ops only.
Action required: 705 - Other - as specified
Due 21 January 2017
Resolved 27 December 2016
Lifesaving › Lifebuoys › Stowage
Issued 21 December 2016 Resolved
Properly mount aft lifering and light.
Action required: 705 - Other - as specified
Due 21 January 2017
Resolved 27 December 2016
Construction/Loadline › Structures › Superstructure
Issued 21 December 2016 Resolved
Replace cracked port fwd berthing window.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 14 February 2017
Resolution: Window replaced.
Fire Fighting › Fire Hoses › Location
Issued 21 December 2016 Resolved
Properly mount fire hoses P/S at fire hydrant stations to be always connected.
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 27 January 2017
Resolution: Fire hoses properly mounted and connected at fire hydrants.
Construction/Loadline › Hull › Hull Plating
Issued 1 December 2016 Resolved
Caulk seam IVO keel scarf joint between shafts.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 7 December 2016
Construction/Loadline › Hull › Hull Plating
Issued 1 December 2016 Resolved
Caulk wood joint IVO port rudder.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 7 December 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 December 2016 Resolved
Remove dead end wires in berthing area.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 1 December 2016
Resolution: Dead end wires removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 December 2016 Resolved
Remove extention cord in fwd berthing and/or hard wire.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 1 December 2016
Resolution: Extention cord removed.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 1 December 2016 Resolved
Label electrcial panel IVO premium berthing area.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 21 December 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 December 2016 Resolved
Adjust wires and replace cover for junction box IVO premium berthing void.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 21 December 2016
Engineering › Feedwater/Condensate Water System › Piping
Issued 1 December 2016 Resolved
Prove proper operation of bait pump piping during sea-trial.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 21 December 2016
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 1 December 2016 Resolved
Reattach chain to fwd hatch cover.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 1 December 2016
Resolution: Chain reattached.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 December 2016 Resolved
Properly mark P/S liferings.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 1 December 2016
Resolution: Liferings properly marked.
Operations/Management › Vessel Activity › Underway
Issued 1 December 2016 Resolved
Make vessel available for post drydock check ride.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 21 December 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 May 2016 Resolved
Prove proper operation of the bilge high level alarm in the midship void, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2016
Resolved 27 May 2016
Resolution: Bilge alarm tested sat.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 25 May 2016 Resolved
Install fire dampeners for ventilation to E/R.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 2 June 2016
Resolution: Fire dampers installed.
Fire Fighting › Fire Main › Valves
Issued 25 May 2016 Resolved
Replace fire station portside valve handle.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 27 May 2016
Resolution: New handle installed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 May 2016 Resolved
Prove proper operation of stbd E-light in fwd salon.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 27 May 2016
Resolution: E-light working properly.
Communications › Radio Communications › VHF Radiotelephone
Issued 25 May 2016 Resolved
Properly connect GPS to VHF-DSC radio.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 27 May 2016
Resolution: Installed VHF-DSC with built in GPS.
Documentation › Certificates/Documents › FCC SSL
Issued 25 May 2016 Resolved
Renew FCC SSL.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 2 June 2016
Resolution: New FCC SSL provided.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 25 May 2016 Resolved
Label electrical panels on bridge and E/R.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 2 June 2016
Resolution: Panels labeled.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 May 2016 Resolved
Secure deck board near stbd MDE.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 27 May 2016
Resolution: Deck board secured.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 25 May 2016 Resolved
Raise CO2 bottles 2" of the deck at next service.
Action required: 705 - Other - as specified
Due 11 February 2017
Resolved 21 December 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 May 2016 Resolved
Install UL1104 mast head light and stern light.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 2 June 2016
Resolution: UL1104 lights installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 May 2016 Resolved
Install UL1104 anchor light prior to COI inspection due 28FEB17.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 21 December 2016
Fire Fighting › Fixed Fire Detection System › Approval
Issued 26 October 2007 Resolved
Provide proposal for installation of Coast Guard approved fire detection system per 46 CFR 180.400(c) NLT 04NOV07 to the satisfaction of the OCMI.
Due 28 December 2007
Resolved 8 February 2008
Resolution: Ansul Checkfire installed to manufactured approval and 46 CFR 180.400(c).
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 21 April 2006 Resolved
Noted apparent lack of random testing of crew. Investigation pending.
Due 21 April 2006
Resolved 29 August 2006
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 3 June 2005 Resolved
Renew retroreflective material as needed on lifefloats. Retroreflective tape renewed prior to the completion of the inspection.
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 3 June 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 June 2005 Resolved
Reduce length of lanyard for attached waterlight on ring buoy and properly install with releasing clip. Lanyard properly installed prior to the completion of the inspection.
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 3 June 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 3 June 2005 Resolved
Clean corrosion from battery terminals on main battery bank. Corrosion cleaned prior to the completion of the inspection.
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 3 June 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 May 2004 Resolved
Prove proper operation of NAV lights.
Action required: 705 - Other - as specified
Due 27 June 2004
Resolved 27 May 2004
Resolution: Proved proper operation of NAV lights.
Fire Fighting › Fire Pumps › Pressure
Issued 27 May 2004 Resolved
Prove proper operation of fire pump discharge pressure gauge.
Action required: 705 - Other - as specified
Due 27 June 2004
Resolved 27 May 2004
Resolution: Proved proper operation of fire pump discharge pressure gauge.
Fire Fighting › Remote Fuel Shutoff
Issued 27 May 2004 Resolved
Label fuel shut off valves.
Action required: 705 - Other - as specified
Due 27 June 2004
Resolved 27 May 2004
Resolution: Labeled fuel shut off valves.
Communications › Radio Communications › EPIRB
Issued 16 May 2003 Resolved
406 MHz EPIRB hydrostatic release unit past expiration date. Vsl operator purchased new HRU and installed prior to the completion of the inspection.
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 16 May 2003
Fire Fighting › Grease Extraction Hood › General
Issued 16 May 2003 Resolved
Install grease extraction hood above galley griddle in accordance with 46 CFR 181.400(d).
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 3 June 2005
Pollution Prevention/Response › Prevention Equipment
Issued 16 May 2003 Resolved
Install locking device for MSD overboard discharge valve. LEGACY COMPONENT DESC: Sewage System Valve
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 4 December 2003
Fire Fighting › Fire Pumps
Issued 16 May 2003 Resolved
Replace fire pump discharge pressure gauge. Pump delivered adequate volume and pressure but discharge gauge did not register. LEGACY COMPONENT DESC: Pressure
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 4 December 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 16 May 2003 Resolved
Clean or renew flame screens for fuel oil tank vents. Vents were partially clogged with dust and paint. LEGACY COMPONENT DESC: Ventilation
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 4 December 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 16 May 2003 Resolved
Replace expired items in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 4 December 2003
Communications › Visual Communication
Issued 16 May 2003 Resolved
Stencil emergency exit from forward berthing space.
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 27 May 2004
Resolution: Stenciled emergency exit from forward berthing space.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 May 2003 Resolved
Forward mast head light did not operate during operational test. Vsl operator repaired prior to the completion of the inspection.
Action required: 705 - Other - as specified
Due 16 May 2003
Resolved 16 May 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2003 Resolved
Noted wire nuts on electrical wires beneath console in pilot house. Vsl operator removed and install proper crimp connection prior to the completion of the inspection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 May 2003
Resolved 16 May 2003
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 16 May 2003 Resolved
Renewed 4 PFD lights during inspection of PFD's.
Action required: 705 - Other - as specified
Due 16 May 2003
Resolved 16 May 2003
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 March 2002 Resolved
Plug hole penetration between #2 bunkroom and engine room.
Condition: Unknown
Due 11 March 2002
Resolved 11 March 2002
Resolution: Repairs made and sealed.
Electrical › Electric Generation Source (service) › Neutral Ground
Issued 11 March 2002 Resolved
Repair broken bonding strap in bilge in #2 bunkroom.
Condition: Improper/Lack of Maintenance
Due 11 March 2002
Resolved 11 March 2002
Resolution: Broken piece replaced by crew.
Engineering › Bilge Water Management System
Issued 11 March 2002 Resolved
Prove proper operation of visual portion of bilge high water alarm for engine room and lazarette.
Condition: Unknown
Due 11 March 2002
Resolved 11 March 2002
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 11 March 2002 Resolved
Renew missing hose clamp on exhaust cooling water line for starboard main engine.
Condition: Unknown
Due 11 March 2002
Resolved 11 March 2002
Electrical › Electrical Distribution System (service) › Cable
Issued 11 March 2002 Resolved
Remove portable electrical cord to fan in forward bunkroom.
Due 11 March 2002
Resolved 11 March 2002
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 11 March 2002 Resolved
Label PFD stowage locker in pilothouse.
Due 11 March 2002
Resolved 11 March 2002
Fire Fighting › Fire Hoses
Issued 11 March 2002 Resolved
Label fire hoses with vessel name.
Due 11 March 2002
Resolved 11 March 2002
Fire Fighting
Issued 31 October 2000 Resolved
INSTALL SMOKE DETECTORS IN ALL ACCOMODATION SPACES AS REQUIRED BY 46 CFR 181.400(C) VESSEL IS RESTRICTED FROM CARRYING PASSENGERS OVERNIGHT UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Navigation
Issued 21 June 2000 Resolved
Replace aft, port broken wheelhouse window.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Fire Fighting
Issued 21 June 2000 Resolved
Install UL approved grease extraction hood or propose alternative inspection and maintenance plan.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Lifesaving
Issued 21 June 2000 Resolved
Provide complete and current first aid kit per 46 CFR 184.710.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Construction/Loadline
Issued 21 June 2000 Resolved
Make bulkhead where starboard main exhaust passes through the aft engine room bulkhead watertight.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Lifesaving
Issued 21 June 2000 Resolved
Install machine guard on starboard main generator.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Fire Fighting
Issued 21 June 2000 Resolved
Provide placard and labels for fixed CO2 system per 46 CFR 185.612 for instructions at primary and alternate station, schematic diagram and label for system.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Fire Fighting
Issued 21 June 2000 Resolved
Provide means of closing port and starboard aft natural vents in engine room.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Lifesaving
Issued 16 March 1999 Resolved
Mark lifefloat paddles with vessels name as per 46 CFR 185.604
Condition: Unknown
Due 16 March 1999
Resolved 30 March 1999
Lifesaving
Issued 16 March 1999 Resolved
Provide proper stowage of lifefloats as per 46 CFR 180.130
Condition: Unknown
Due 16 March 1999
Resolved 30 March 1999
Construction/Loadline
Issued 16 March 1999 Resolved
Repair rotted deck under starboard head. Provide MSO with written plan proposal.
Condition: Unknown
Due 16 March 1999
Resolved 16 March 1999
Lifesaving
Issued 16 March 1999 Resolved
Relace painters on 3 aluminum lifefloats and all weaklinks_x001C_
Condition: Unknown
Due 16 March 1999
Resolved 30 March 1999
Electrical
Issued 27 May 1998 Resolved
Owner is to remove non-approved wiring to Fan in forward passenger area_x001C_ and replace it with approved marine grade wire.
Condition: Unknown
Due 27 May 1998
Resolved 27 May 1998
Electrical
Issued 27 May 1998 Resolved
Owner is to remove non-approved wiring to vent fan in galley ang replace itwith approved marine grade wire.
Condition: Unknown
Due 27 May 1998
Resolved 27 May 1998
Construction/Loadline
Issued 27 May 1998 Resolved
Vessel's owner is to remove temp patch on the port deck and repair or replace deck and members as needed. Owner is to call local OCMI to have marine inspector come out and inspect the deck area prior to doing any workafter the deck patch is removed.
Condition: Unknown
Due 27 May 1998
Resolved 27 May 1998
Electrical
Issued 27 May 1998 Resolved
Owner is to remove non-approved wiring in aft passenger area and replace itwith approved marine grade wiring.
Condition: Unknown
Due 27 May 1998
Resolved 27 May 1998
Electrical
Issued 27 May 1998 Resolved
Owner is to remove wiring to blower in forward passenger area and replace with approved marine grade wire. replacement is to be done NLT 28JUN98.
Condition: Unknown
Due 27 May 1998
Resolved 27 May 1998
Navigation
Issued 15 March 1995 Resolved
UPDATE CHARTS AND PROVIDE AN UPDATED LIGHT LIST
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Documentation
Issued 16 March 1994 Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING WITHIN THE LAST TWELVE MONTHS.
Condition: Unknown
Due 30 March 1994
Resolved 1 April 1994
Engineering
Issued 18 March 1993 Resolved
REPLACE DETIORATED FUEL VENT HOSES ON 4 ENINE ROOM FUEL OIL TANKS WITH VENTLINES MADE OF METALIC PIPE.
Condition: Unknown
Due 7 June 1993
Resolved 7 June 1993
Accommodation/Occupational Safety
Issued 18 March 1993 Resolved
CONNECT ALL TOILETS TO TYPE III MSD HOLDING TANK
Condition: Unknown
Due 7 June 1993
Resolved 7 June 1993
Lifesaving
Issued 19 March 1992 Resolved
REPLACE 1 WATERLIGHT ON FWD LIFEFLOAT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 20 March 1992
Resolved 20 March 1992
Accommodation/Occupational Safety
Issued 19 March 1992 Resolved
REPAIR WINDOW ON STBD SIDE PASSENGER SPACE.
Condition: Unknown
Due 24 March 1992
Resolved 24 March 1992
Construction/Loadline
Issued 12 December 1990 Resolved
INSTALL SEA VALVE ON THROUGH HULL FITTING PORT SIDE, MID SHIPS.
Condition: Unknown
Due 12 December 1990
Resolved 12 December 1990
Electrical
Issued 12 December 1990 Resolved
INSTALL COVER FOR FLORESCENT LIGHT FIXTURES IN ENGINE ROOM
Condition: Unknown
Due 12 December 1990
Resolved 12 December 1990
Accommodation/Occupational Safety
Issued 12 December 1990 Resolved
PROVIDE LOCKING MECHANISM FOR HEAD OVER BOARD-SEA VALVES.
Condition: Unknown
Due 12 December 1990
Resolved 12 December 1990
Engineering
Issued 12 December 1990 Resolved
REMOVE LINE HOLDING THROTTLE CABELS FOR BOTH MAIN ENGINES AND REPLACE WITH APPROPRIATE SUPPORTS.
Condition: Unknown
Due 12 December 1990
Resolved 12 December 1990
Construction/Loadline
Issued 12 December 1990 Resolved
MAKIE ENGINE ROOM HATCH WATERTIGHT VESSEL IS RESTRICED TO LAKES BAYS AND SOUNDS. UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 12 December 1990
Resolved 12 December 1990
Construction/Loadline
Issued 12 December 1990 Resolved
SCRAPE AND TREAT FURRING WOOD ABOVE PORT FUEL TANK IN ENGINE ROOM.
Condition: Unknown
Due 12 December 1990
Resolved 12 December 1990
Accommodation/Occupational Safety
Issued 12 December 1990 Resolved
CROP AND RENEW ROTTED SHEET OF PLYWOOD MOUNTED VERTICAL AS FWD WATER MAKER BASE
Condition: Unknown
Due 12 December 1990
Resolved 12 December 1990
Construction/Loadline
Issued 12 December 1990 Resolved
FIT GRAVING PIECE IN STARBOARD GARBOARD STRAKE, FIT UP TO BE WITNESSED BY COAST GUARD INSPECTOR PRIOR TO LEAVING DRYDOCK.
Condition: Unknown
Due 12 December 1990
Resolved 12 December 1990
Engineering
Issued 22 March 1990 Resolved
CLEAN PORT AND STARBOARD FUEL TANK FLAME SCREENS AND REPLACE AFT FUEL TANK FLAME SCREEN WITH 30X30 MESH SCREEN.
Condition: Unknown
Due 22 March 1990
Resolved 22 March 1990
Engineering
Issued 22 March 1990 Resolved
PROVIDE FLAME GUARDS FOR PORT AND STARBOARD OUTBOARD FUEL TANK EMERGENCY SHUT OFF HANDLES.
Condition: Unknown
Due 22 March 1990
Resolved 22 March 1990
Navigation
Issued 22 March 1990 Resolved
REPAIR STARBOARD RUNNING LIGHT TO MATCH INTENSITY OF PORT RUNNING LIGHT, UNTIL CORRECTED VESSEL IS RESTRICTED TO DAYLIGHT OPERATION.
Condition: Unknown
Due 22 March 1990
Resolved 22 March 1990
Engineering
Issued 22 March 1990 Resolved
PROVIDE VESSEL WITH A SECOND POWER BILGE PUMP.
Condition: Unknown
Due 22 March 1990
Resolved 22 March 1990
Documentation
Issued 22 March 1990 Resolved
PROVIDE VESSEL WITH A CURRENT FCC RADIOTELEPHONY SAFETY CERTIFICATE.
Condition: Unknown
Due 22 March 1990
Resolved 22 March 1990
Construction/Loadline
Issued 22 March 1990 Resolved
REMOVE AND TREAT ROT FROM ALL OVERHEAD AREAS, UNDERDECK AREAS, AND UPPER SECTIONS OF SIDE FRAMING IN ENGINEROOM.
Condition: Unknown
Due 22 March 1990
Resolved 22 March 1990
Construction/Loadline
Issued 22 March 1990 Resolved
REMOVE AND TREAT ROT FROM UPPER SECTIONS OF FRAMES 2 THROUGH 6 PORT AND STARBOARD IN FOREPEAK.
Condition: Unknown
Due 22 March 1990
Resolved 22 March 1990
Electrical
Issued 22 March 1990 Resolved
REPLACE 110V OUTLET IN FOREPEAK WITH OUTLET SUITABLE FOR USE IN WET LOCATIONS.
Condition: Unknown
Due 22 March 1990
Resolved 22 March 1990
Electrical
Issued 22 March 1990 Resolved
REMOVE DEAD-END WIRING AND REPLACE BROKEN WIRE HANGERS IN FOREPEAK.
Condition: Unknown
Due 22 March 1990
Resolved 22 March 1990
Construction/Loadline
Issued 22 March 1990 Resolved
COMPLETE CREDIT DRYDOCK BY 31 MAY 1990.
Condition: Unknown
Due 22 March 1990
Resolved 22 March 1990
Fire Fighting
Issued 22 March 1990 Resolved
PROVIDE VESSEL WITH FIRE PUMP IN ACCORDANCE WITH 46 CFR 181.10.
Condition: Unknown
Due 22 March 1990
Resolved 22 March 1990
Fire Fighting
Issued 22 March 1990 Resolved
PROVIDE MOUNTS FOR HOSE ADJACENT TO FIRE STATIONS.
Condition: Unknown
Due 22 March 1990
Resolved 22 March 1990
Fire Fighting
Issued 22 March 1990 Resolved
PROVIDE ONE ADDITIONAL B-II FIRE EXTINGUISHER FOR A TOTAL OF 5 B-II'S.
Condition: Unknown
Due 22 March 1990
Resolved 22 March 1990

Casualty record · 1

4 April 2013Routine · role: Involved in a Marine Casualty · activity 4724398
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.