Records from 2013 to 2026. Most recent: inspection, 13 August 2026.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 September 2024
Resolved
Vessel rep reported to SSD that the vessel impacted a rouge wave and caused damage to the stbd forward Bulwark. No water ingress was reported, the vessel ended the voyage and safely returned to San Diego. Verbal no sail was issued to vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2024
Resolution: Vessel made temporary repairs as approved by Sector San Diego.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 March 2024
Resolved
On vessels described by 46 CFR 175.110(d) of this chapter, a passenger safety bill must be posted by the master in each cabin or stateroom, and in passenger accommodation spaces. Vessel did not have the passenger safety bill posted in passenger accommodation spaces. Post passenger safety bill to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 3 April 2024
Resolution: Vessel posted Passenger Safety Bill.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 March 2024
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows:
(1) Spaces storing carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.”.
(2)Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” The reference to wintergreen scent may be omitted for carbon dioxide systems not required to have odorizing units and not equipped with such units. Vessel was missing required CO2 warning signs. Install CO2 warning signs for aft compartment and machinery space entrance to satisfaction of attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 3 April 2024
Resolution: Vessel posted CO2 warning signs outside of machinery space and CO2 storage room.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 March 2023
Resolved
Emergency egress training for each member of the crew, to occur for all members of the crew - (i) At least monthly while such members are employed on board the vessels; and (ii) Each time a crew member joins the crew of such vessel. Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information. (1) Date of the training; and (2) General description of the training topics. Egress training records were not available. Conduct and log monthly egress training.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 27 March 2023
Resolution: Vessel provided log of training and drill.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2023
Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. An electrical receptacle was found behind the forward berthing stairs unmounted and hanging by the cables. Properly mount electrical receptacle and install cable supports.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2023
Resolved 31 March 2023
Resolution: Vessel re-mounted electrical receptical.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 December 2022
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel did not install an interconnected fire detection system by 27DEC2022.
Vessel is restricted to a LIMITED COASTWISE route and is prohibited from allowing passengers to utilize overnight accomodations until it's compliance with the interconnected fire detection requirements of 46 CFR 181.405 have been verified by a USCG marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 31 March 2023
Resolution: Vessel installed interconnected fire detection and roving watch monitoring devices which were satisfactorily tested.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 28 November 2022
Resolved
All passenger accommodations must be arranged and equipped to provide for the safety of the passengers in consideration of the route, modes of operation, and speed of the vessel. The deck in the forward passenger bunk room was found to be constructed of general plywood and with areas of severe delamination, warping and soft areas due to chronic moisture damage. Owner plans to replace after dry dock but prior to using the space for passenger accomodation. Replace floor to the satisfaction of the attending marine inspector prior to using for passengers but no later than 01APR2023.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 April 2023
Resolved 9 March 2023
Resolution: Vessel replaced decking.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 November 2022
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended in this section. Portable 2-A fire extignuisher located in the forward passenger berthing area was found with a depleted charge. Service or replace fire extinguisher.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2022
Resolved 28 November 2022
Resolution: Vessel had fire extinguisher serviced.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 November 2022
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. One deckhand had taken his preemployment test but had not received results at the time of inspection. Vessel was manned above the minimum required by the COI. Provide documentation of negative test prior to employment in a safety sensitive position.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2022
Resolved 28 November 2022
Resolution: Vessel provided updated covered crew list showing full compliance for the identified crew member.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 January 2022
Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. The carbon dioxide fixed fire suppression system activation pressure switch did not shut down either generator located in the engine room. Install and demonstrate operation of engine shut downs.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 5 April 2022
Resolution: Vessel installed and tested engine shut downs.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 12 January 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2022
Resolved 25 February 2022
Resolution: Vessel provided current FCC certificates.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 12 January 2022
Resolved
Except when in the judgment of the cognizant OCMI the operation of a vessel does not present one of the hazards listed, the emergency instruction placard should contain at least the applicable portions of the “Emergency Instructions” listed in § 185.512. The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Vessel's emergency instructions were not vessel specific. Provide vessel specific emergency instructions.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2022
Resolved 28 January 2022
Resolution: Vessel provided revised emergency instructions.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 January 2022
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Records of tests and inspections required by 46 CFR 176.810(b) were not available. Provide records.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2022
Resolved 18 February 2022
Resolution: The vessel provided records of servicing.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 January 2022
Resolved
The Rules concerning shapes shall be complied with by day. The lights and shapes specified in these Rules shall comply with the provisions of Annex I of these Rules (33 CFR part 84). Vessel was not carrying day shapes. Provide day shapes.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2022
Resolved 28 January 2022
Resolution: Vessel provided day shapes.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 January 2022
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly portable extinguisher inspections records not available. Conduct and record inspections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 28 January 2022
Resolution: Vessel provided records of inspections.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 January 2022
Resolved
Fire, abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Drill records only contained the date and general type of drill (fire, MOB, abandon ship). Conduct and log drills to include the above information.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 28 January 2022
Resolution: Vessel provided acceptable logs showing completion of drills.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 23 July 2021
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members.
All vessels with overnight accommodations must be equipped with a general alarm system. The public address system required by §184.610 of this chapter may be used to sound the general alarm signal.
Vessel's Public Address and General Alarm system was not sufficiently audible during normal operating conditions in the passenger bunk spaces. Demonstrate operation of Public Address and General Alarm of adequate volume in all accommodation spaces.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 12 August 2021
Resolution: Vessel installed additional public address speakers and demonstrated operation and volume via video.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 July 2021
Resolved
Each ring buoy on a vessel mus be approved in accordance with §160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Port forward ring buoy was found deteriorated and worn. Provide ring buoy meeting specifications of 46 CFR 160.050.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 5 August 2021
Resolution: Vessel provided pictures of replacement ring life buoy installed on vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 July 2021
Resolved
On a vessel on a voyage of more than 24 hours duration, passengers shall be requested to don life jackets and go to the appropriate embarkation station during the safety orientation. If only a small number of passengers embark at a port after the original muster has been held, these passengers must be given the passenger safety orientation required by paragraphs (a) or (b) of this section if another muster is not held. Vessel did not require passengers to don life jackets during the safety orientation for a three day voyage. After discussion between inspector and vessel master, passengers donned life jackets and deficiency was corrected.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 23 July 2021
Resolution: Vessel required donning after notification by attending inspector.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 11 February 2021
Resolved
Emergency instructions missing instructions for man overboard and rough weather. Provide additional instructions.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2021
Resolved 23 February 2021
Resolution: Vessel updated emergency instructions to include all scenarios required by regulation.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 11 February 2021
Resolved
Aft crew bunk room missing speaker for public address and general alarm. Provide speaker.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2021
Resolved 23 February 2021
Resolution: Vessel installed additional public address/GA speaker in crew berthing and demonstrated operation.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 March 2020
Resolved
Provide current and complete first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 April 2020
Resolution: New first aid kit provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 March 2020
Resolved
Provide fire hose nozzle capable of straight and wide spray.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 April 2020
Resolution: Fire nozzles replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 March 2020
Resolved
Provide spanner wrenches at all fire stations.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 April 2020
Resolution: Spanner wrenches provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2020
Resolved
Remove permanent extension cord powering bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 April 2020
Resolution: Pump rewired correctly.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 11 March 2020
Resolved
Provide plan to replace mattresses or demonstrate compliance with flammability standards.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 April 2020
Resolution: Recieved plan for mattress change out and proof of flammability standards.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2020
Resolved
Unground outlets found throughout Demonstrate proper grounding of outlets.
Due by the end of next drydock.
Action required: 705 - Other - as specified
Resolved 30 December 2020
Resolution: Vessel repaired un-grounded outlets and replaced old outlets not making ground connection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2020
Resolved
Provide dead end covers on distribution panel in pilot house.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 April 2020
Resolution: Dead end covers installed.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 March 2020
Resolved
Provide log showing fire, MOB, abandon ship drills as well as epirb & fire ext. inspections.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2020
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 10 October 2019
Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously.
Action required: 10 - Deficiency Rectified
Due 10 October 2019
Resolved 10 October 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 October 2019
Resolved
Vessel required to have the appropriate number of independent modular smoke detection and alarm units in accommodation spaces that are in compliance with UL 217. Must install units in closed berthing spaces amidships of vessel to satisfaction of Coast Guard Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2019
Resolved 11 March 2020
Resolution: Vessel has the required detectors installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 October 2019
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from passenger and crew accommodation spaces below the main deck. Must install emergency lighting in forward sections of port and starboard fwd berthing spaces to satisfaction of CG Marine Inspections.
Action required: 705 - Other - as specified
Due 10 January 2020
Resolved 11 March 2020
Resolution: Emergency lighting installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 October 2019
Resolved
All major appliances on board vessels must be hard wired to the outlet. Freezer in aft accommodation space was plugged into an extension cord. Must rectify to satisfaction of CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2019
Resolved 4 November 2019
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 13 February 2018
Resolved
Provide pre-employment test results for crew member prior to working on board with PAX.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 21 February 2018
Resolution: Crew member decided not to work for the vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 February 2018
Resolved
Hard wire freezer in aft space or provide an outlet so that extention cords are not used.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 February 2018
Resolved 13 February 2018
Resolution: Freezer moved to use existing outlet.
Construction/Loadline › Hull › Transverse Frame
Issued 29 November 2017
Resolved
Repair frames in the bow area as indicated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 10 January 2018
Resolution: All frames in the bow area we fixed as indicated.
Construction/Loadline › Hull › Hull Plating
Issued 21 December 2016
Resolved
Due to water ingress at port chine just aft of the collision bulkhead; open area up for further inspection, make proper repairs, and complete a post repair sea-trial prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 December 2016
Resolved 27 December 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 December 2016
Resolved
Prove proper operation of the port nav light; restricted to daylight ops only.
Action required: 705 - Other - as specified
Due 21 January 2017
Resolved 27 December 2016
Lifesaving › Lifebuoys › Stowage
Issued 21 December 2016
Resolved
Properly mount aft lifering and light.
Action required: 705 - Other - as specified
Due 21 January 2017
Resolved 27 December 2016
Construction/Loadline › Structures › Superstructure
Issued 21 December 2016
Resolved
Replace cracked port fwd berthing window.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 14 February 2017
Resolution: Window replaced.
Fire Fighting › Fire Hoses › Location
Issued 21 December 2016
Resolved
Properly mount fire hoses P/S at fire hydrant stations to be always connected.
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 27 January 2017
Resolution: Fire hoses properly mounted and connected at fire hydrants.
Construction/Loadline › Hull › Hull Plating
Issued 1 December 2016
Resolved
Caulk seam IVO keel scarf joint between shafts.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 7 December 2016
Construction/Loadline › Hull › Hull Plating
Issued 1 December 2016
Resolved
Caulk wood joint IVO port rudder.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 7 December 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 December 2016
Resolved
Remove dead end wires in berthing area.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 1 December 2016
Resolution: Dead end wires removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 December 2016
Resolved
Remove extention cord in fwd berthing and/or hard wire.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 1 December 2016
Resolution: Extention cord removed.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 1 December 2016
Resolved
Label electrcial panel IVO premium berthing area.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 21 December 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 December 2016
Resolved
Adjust wires and replace cover for junction box IVO premium berthing void.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 21 December 2016
Engineering › Feedwater/Condensate Water System › Piping
Issued 1 December 2016
Resolved
Prove proper operation of bait pump piping during sea-trial.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 21 December 2016
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 1 December 2016
Resolved
Reattach chain to fwd hatch cover.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 1 December 2016
Resolution: Chain reattached.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 December 2016
Resolved
Properly mark P/S liferings.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 1 December 2016
Resolution: Liferings properly marked.
Operations/Management › Vessel Activity › Underway
Issued 1 December 2016
Resolved
Make vessel available for post drydock check ride.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 21 December 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 May 2016
Resolved
Prove proper operation of the bilge high level alarm in the midship void, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2016
Resolved 27 May 2016
Resolution: Bilge alarm tested sat.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 25 May 2016
Resolved
Install fire dampeners for ventilation to E/R.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 2 June 2016
Resolution: Fire dampers installed.
Fire Fighting › Fire Main › Valves
Issued 25 May 2016
Resolved
Replace fire station portside valve handle.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 27 May 2016
Resolution: New handle installed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 May 2016
Resolved
Prove proper operation of stbd E-light in fwd salon.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 27 May 2016
Resolution: E-light working properly.
Communications › Radio Communications › VHF Radiotelephone
Issued 25 May 2016
Resolved
Properly connect GPS to VHF-DSC radio.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 27 May 2016
Resolution: Installed VHF-DSC with built in GPS.
Documentation › Certificates/Documents › FCC SSL
Issued 25 May 2016
Resolved
Renew FCC SSL.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 2 June 2016
Resolution: New FCC SSL provided.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 25 May 2016
Resolved
Label electrical panels on bridge and E/R.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 2 June 2016
Resolution: Panels labeled.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 May 2016
Resolved
Secure deck board near stbd MDE.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 27 May 2016
Resolution: Deck board secured.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 25 May 2016
Resolved
Raise CO2 bottles 2" of the deck at next service.
Action required: 705 - Other - as specified
Due 11 February 2017
Resolved 21 December 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 May 2016
Resolved
Install UL1104 mast head light and stern light.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 2 June 2016
Resolution: UL1104 lights installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 May 2016
Resolved
Install UL1104 anchor light prior to COI inspection due 28FEB17.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 21 December 2016