CORAL SEA

CORAL SEA is a 1961 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in February 2025, along with 18 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 21 February 2025.

Built
1961
Last inspected
21 February 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 February 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH9770
Flag
UNITED STATES
Maury page id
psix-44041

Documentation record

Registered dimensions (L × B × D)48.9 ft × 17.4 ft × 8.1 ft
Registered tonnagegross 51 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCRUIZON BOAT WORKS · SURFSIDE, CA, UNITED STATES · built 1961
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSANTA BARBARA, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 January 2026 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

21 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 21

21 February 2025 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8081886
3 February 2025 Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8076357
31 July 2024 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7981087
22 March 2024 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7887320
22 December 2023 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7841830
2 March 2023 In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7638092
12 January 2023 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7618240
6 December 2022 Plan Review "T" Boat · Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7605282
26 August 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7540245
15 February 2022 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7396154
24 August 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7313714
24 February 2021 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7137571
8 January 2021 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7118699
24 February 2020 COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6906224
4 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6817085
9 April 2019 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6658896
4 January 2019 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6604969
3 May 2018 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6389934
27 February 2017 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6095997
6 January 2017 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6066687
24 February 2016 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5820575

Deficiency record · 18

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 15 February 2022 Resolved
Vessel must meet survival craft requirements as per the table in 46 CFR 180.200(c). Vessel is currently missing 01 (30 person) IBA as required on the vessel's COI due to it being found un-serviceable at a servicing facility. Vessel has satisfactorily installed 01 (25 person) loaned IBA on board. Due to vessel operating in cold water months for its operating area as dictated in NVIC 07-91, the vessel is limited to 25 total persons allowed (this number includes crew), while current IBA is on-board. During cold water months, January 1st to February 28th, and from March 1st through May 31st when operating North of a line drawn 255 degrees true from the San Mateo Point Light at latitude 33-23 north, the vessel is limited to 25 total persons while the (25 person) IBA is on board. This CG-835 will remain in effect until such time that the vessel is able to prove satisfactory primary lifesaving for additional persons.
Action required: 705 - Other - as specified
Resolved 25 February 2022
Resolution: Vessel has satisfactorily installed 01 30 person IBA.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 February 2021 Resolved
Pre-engineered fixed firefighting system (Fireboy) does not prevent engine restart after shutdown. Demonstrate proper operation of interlock.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 5 March 2021
Resolution: Vessel had new fireboy installed and provided video to MI demonstrating function test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 February 2021 Resolved
Ring lifebuoy water light inoperable. Demonstrate proper operation.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 March 2021
Resolved 24 February 2021
Resolution: Vessel replaced battery and demonstrated operation.
09 - Working and Living Conditions › 091 - Living Conditions › Berth dimensions, etc.
Issued 4 October 2019 Resolved
Each bunk shall be immediately adjacent to an aisle leading to a means of escape from the lounge area. Vessel has double occupancy bunks installed which does not allow rapid egress in an emergency. Reduce number of overnight passengers to 21 so that bunks are single occupancy only. **705 C, Prior to carrying more than one person in double bunks.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 October 2019
Resolved 18 January 2020
Resolution: COI amended to reflect reduced numbers.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 October 2019 Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets. The required 2.5 gallon fire buckets were not onboard the vessel. Provide 03, 2.5 gallon fire buckets with lanyards to be kept ready for use aboard the vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2019
Resolved 18 January 2020
Resolution: Fire buckets provided.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 October 2019 Resolved
The existing mattresses used in the passenger sleeping bunks were not flame retardant. Provide flame retardant treatment to the mattresses or provide new mattress's that meet the flame retardant requirements of new subchapter "T".
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2019
Resolved 18 January 2020
Resolution: Vessel applied No-Burn to existing mattresses (see attached letter from owner).
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 9 April 2019 Resolved
EPIRB hydrostatic release expired. Vessel restricted to 3 NM from land until corrected.
Action required: 10 - Deficiency Rectified
Due 9 April 2019
Resolved 9 April 2019
Resolution: Vessel purchased and installed new hydrostatic release.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 May 2018 Resolved
Properly mark lifejacket storage locations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2018
Resolved 8 May 2018
Resolution: Location marked.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 3 May 2018 Resolved
Properly mark fwd escape hatch.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2018
Resolved 8 May 2018
Resolution: Hatch marked.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 27 February 2017 Resolved
Properly mount IBA.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 27 February 2017
Resolution: Corrected on the spot.
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 February 2017 Resolved
Update coast pilot, light list and chart.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 27 February 2017
Resolution: Corrected on the spot.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 February 2017 Resolved
Install blanks in electrical panel in stbd berthing.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 27 February 2017
Resolution: Corrected on the spot.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 27 February 2017 Resolved
Properly mount fire extinguisher on the bridge.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 27 February 2017
Resolution: Corrected on the spot.
Communications › Radio Communications › VHF Radiotelephone
Issued 27 February 2017 Resolved
Connect GPS to VHF-DSC radio.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 27 February 2017
Resolution: Corrected on the spot.
Communications › Alarms/Indicators › High Water Alarm
Issued 6 January 2017 Resolved
Replace & re-mount bilge high-water alarm.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 24 January 2017
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 6 January 2017 Resolved
Forepeak: Make bilge pipe penetration of collision bulkhead watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 24 January 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 January 2017 Resolved
Port stateroom: Re-route cable to breaker box to protect inner wires.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 24 January 2017
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 24 February 2016 Resolved
Properly connect IBA painter to the hydrostatic release.
Action required: 705 - Other - as specified
Due 24 February 2016
Resolved 24 February 2016
Resolution: Corrected prior to completion of inspection.