MAURY USCG vessel records Sign in
← All vessels

OLD GLORY

OLD GLORY is a 1968 passenger vessel (inspected). The Coast Guard has recorded 102 inspections since 1985, most recently in July 2026, along with 269 deficiencies, 1 operational control and 8 casualty investigations between 2002 and 2023.

Records from 1985 to 2026. Most recent: inspection, 15 July 2026.

Built
1968
Last inspected
15 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH5594
Flag
UNITED STATES
367629440
Maury page id
psix-45910

Inspections, by type

…with no type recorded18
Years with a record 38 calendar years (1985–2026)
The 102 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)79.5 ft × 21.1 ft × 8.0 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA BOAT COMPANY · COSTA MESA, CA, UNITED STATES · built 1968
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 27 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ3765MMSI 367629440 · active · compulsorily equipped · granted 17 May 2025, expires 17 May 2035
WDH5594MMSI 367629440 · cancelled · compulsorily equipped · granted 25 June 2014, cancelled 2 April 2021
WDA8900MMSI 366859260 · expired · compulsorily equipped · granted 25 June 2002, cancelled 25 August 2012
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CORAL SEA Passenger (Inspected) · MISLE 44041 · 14 October 1995 · activity 150627

Inspection history · 102

15 July 2026 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8439538
13 May 2026 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8354257
1 May 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8127059
9 April 2025 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8108493
27 June 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7946360
13 June 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7713963
13 June 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7883557
22 April 2023 Drydock Exam · Deficiency Check · Damage Survey · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7674856
22 April 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7686287
29 April 2022 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7440871
26 January 2022 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7386298
1 December 2021 Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7360791
9 June 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7219745
9 October 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7115190
11 June 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6973777
27 December 2019 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6879115
18 December 2019 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6872845
1 October 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6825757
6 June 2019 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6705464
11 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6537789
6 June 2018 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6435836
5 December 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6318551
9 May 2017 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6131815
7 June 2016 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5900023
7 January 2016 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5792859
25 June 2014 Annual Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4899251
15 May 2012 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4312287
16 December 2009 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3651520
22 August 2008 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3306102
7 July 2008 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3263811
2 June 2008 Damage Survey · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3281163
1 June 2008 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3322808
2 April 2008 COI Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3171072
6 December 2007 Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3094727
10 October 2007 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3076910
18 September 2007 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3076809
11 July 2007 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2989847
22 May 2007 Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2877053
23 July 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2739284
15 March 2006 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2602957
25 January 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2568346
28 November 2005 Construction Oversight · Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2509191
24 February 2005 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2293658
15 April 2004 Deficiency Check · Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2026246
18 December 2003 Deficiency Check · Administrative Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1966495
18 November 2003 Deficiency Check · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1933140
19 February 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1746563
10 January 2003 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1728252
6 January 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1729759
23 May 2002 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1620053
17 May 2002 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1618094
15 May 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1719787
8 May 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1614608
15 April 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1604180
2 November 2001 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1444638
31 January 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1048100
9 December 1999 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1424848
17 November 1999 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1406602
26 August 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1461208
18 May 1999 Plan Review "T" Boat · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1467623
23 March 1999 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1111833
17 February 1999 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1128168
1 December 1998 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 811064
21 October 1998 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 803728
26 December 1997 Re-Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1364575
18 March 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 214263
11 December 1996 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1385857
20 October 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1413063
2 May 1996 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1385718
21 November 1995 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1394440
14 October 1995 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 150627
2 June 1995 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1392317
13 March 1995 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1173424
22 November 1994 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1396227
8 April 1994 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1394078
17 December 1993 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1420820
2 April 1993 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1362734
21 January 1993 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1136743
16 November 1992 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1467830
10 February 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1267769
22 January 1992 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1263122
12 April 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 901342
10 April 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1212359
22 March 1991 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1305095
24 January 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1225240
22 January 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 904984
15 January 1991 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1241432
5 January 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 930092
20 December 1989 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1214583
4 December 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1238259
15 December 1988 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 898718
7 December 1988 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 898506
25 May 1988 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1200032
7 January 1988 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1316487
17 December 1987 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1005098
14 May 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1332485
30 December 1986 Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1309582
20 May 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 988224
8 January 1986 COI Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 990705
12 June 1985 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 984858
25 January 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 978086
11 January 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 974956

Deficiency record · 269

02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 15 July 2026 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel hit a buoy which cause damage to the bow of the vessel. Submit repair plan to local OCMI for approval.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2026
Resolution: Vessel completed repairs in Santa Barbara. All SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2026 Resolved
Nothing in this subpart limits the marine inspector from conducting such tests or inspections he or she deems necessary to be assured of the vessel’s seaworthiness. During emergency dry-dock MI discovered excessive pitting on both props. Have props replaced or repaired in accordance with regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2026
Resolved 11 August 2026
Resolution: Received photos of new props installed. All SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2026 Resolved
On a vessel of not more that 65 feet in length carrying more than 49 passengers, and on a vessel of more than 65 feet in length, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure on not less than 60 PSI at the pump outlet. Fire pump was not putting out required pressure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2026
Resolution: Fire pump was capable of meeting required pressure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2026 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve was hard to operate due to cracked shielding.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2026
Resolution: Fuel Shutoff valve moved freely
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2026 Resolved
Electrical equipment on a vessel must be installed to protect the vessel from electrical hazards, including fire. Breaker box in E/R, Portside, FWD was not secured. Secure panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 1 June 2026
Resolution: MI attended vessel All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2026 Resolved
Electrical equipment on a vessel must be installed to protect the vessel from electrical hazards, including fire. Dead-end wires were found in main bunk room, A/C room, Main S/B plug socket, outside operating station and under wheel house. Remove or properly enclose them and update electrical drawing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 1 June 2026
Resolution: MI attended vessel All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2026 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Anchor light was inoperable. Provide navigation lights that are in compliance with the Navigation Rules.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 1 June 2026
Resolution: MI attended vessel All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2026 Resolved
Water lights should be serviceable and batteries replaced annually if not marked with an expiration date. Water light's were inoperable on 16 adult life jackets and 1 child's life jackets. Provide serviceable water light and replace battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 1 June 2026
Resolution: MI attended vessel All SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2025
Resolved 19 May 2025
Resolution: Received picture of the new station license.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 May 2025 Resolved
Vessel's rescue ladder is too short. Replace or modify the vessel's rescue ladder so that it is long enough to account for the vessel's maximum freeboard, to the satisfaction of the attending USCG marine inspector. Cite: 46 CFR 180.210.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2025
Resolved 16 May 2025
Resolution: A rung was added to the bottom of the ladder using heavy line and an aluminum step.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 May 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. STBD generator was leaking oil from oil filter. Replace or prove oil leak has been corrected. Cite: 46 CFR 182.100.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2025
Resolved 16 May 2025
Resolution: Leak was corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. STBD shaft seal was leaking excessively into bilge. Cite: 46 CFR 182.100.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2025
Resolved 16 May 2025
Resolution: Seal was tightened. A minor leak still exists but is within acceptable limits.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Batteries in aft engine room on portside showed corrosion on the battery terminal. Clean battery terminal back to original state. Cite: 46 CFR 183.200.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2025
Resolved 16 May 2025
Resolution: Battery terminals were cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found on portside in engine room compartment. Remove dead end wiring and update electrical plans. Cite: 46 CFR 183.200(c).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2025
Resolved 16 May 2025
Resolution: Dead end wire was removed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 May 2025 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Laz bilge alarm light is not operational at operating station. Fix light at operating station. Cite: 46 CFR 182.530(a).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2025
Resolved 19 May 2025
Resolution: Received picture of the bilge alarm light operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 May 2025 Resolved
As stated in letter dated 21MAR2024, vessel must comply with Fire Safety of Small Passenger Vessels Interim Final Rule requirements by the next scheduled dry dock or 01JAN2026, whichever comes first. Vessel does not yet meet requirements. When carrying more than 6 passengers, vessel is restricted from carrying overnight passengers or allowing passengers in the bunk rooms. National Defense Authorization Act for Fiscal Year 2024 (H.R. 2670), Section 3531(b)
Action required: 705 - Other - as specified
Resolved 13 May 2025
Resolution: Witnessed satisfactory egress drills. Final IFR compliance letter to be issued shortly.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 June 2024 Resolved
One of the vessel's integrated fire detectors is making false alarms. Repair/replace the affected detector and complete a satisfactory test in front of a USCG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2024
Resolution: Detector was replaced and tested all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2024 Resolved
Steering ram connection bolt was found to be excessively loose. Tighten the affected bolt.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2024
Resolution: Bolt was tightened.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 June 2024 Resolved
Vessel's liferafts hydrostatic releases are expired. Acquire and install new hydrostatic releases for the rafts.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2024
Resolution: New hydros were acquired and installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 June 2024 Resolved
Vessel does not have evidence of a valid FCC Radiotelephony Safety Certificate or FCC Station Licese. Provide evidence of the valid certificates. This deficiency is to be rectified by 11 July 2024.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 16 July 2024
Resolution: Received scan of new certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2023 Resolved
Distribution panel IWO port side Lazarette space found to be missing blanks. Install blanks in panel to prevent shock hazard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 June 2023
Resolution: Installed Blanks
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 June 2023 Resolved
Vessel found to be missing servicing records for Gaylord extinguishing system in the galley. Provide proof of annual service to Coast Guard inspectors.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 June 2023
Resolution: Provided service records
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 April 2023 Resolved
Vessel's starboard shaft snapped while underway. Replace damaged shaft, and draw port shaft for examination by USCG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2023
Resolution: Newly fabricated shafts were installed and satisfactory sea trials were conducted on this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2022 Resolved
Exhaust gas must not leak from the piping or any connections. Observed wet exhaust leak on starboard main wet exhaust piping. Must repair to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 15 June 2022
Resolution: Picture emailed to MI...[name withheld]
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 April 2022 Resolved
Each distribution panel or switchboard must be totally enclosed. Observed two (2) inch opening on the right side of the main switchboard. Must repair to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 15 June 2022
Resolution: Picture sent to MI...[name withheld]
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 April 2022 Resolved
High Pressure CO2 fixed gas system piping, valves, and fittings must be securely supported, and where necessary, protected against damage. Observed unsupported four (4) foot un-supported section of CO2 piping in engine space. Must repair to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 15 June 2022
Resolution: Picture sent to MI...[name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 April 2022 Resolved
The fire pump outlet must be fitted with a pressure gauge. Observed pressure gauge without protected cover over analog reader. Must repair to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 15 June 2022
Resolution: Picture sent to MI...[name withheld]
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 29 April 2022 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. No flamescreen was installed on the vent pipe end from the fuel tank. Must repair to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 15 June 2022
Resolution: Picture sent to MI...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 29 April 2022 Resolved
All observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Observed missing ladder rung from 01 nav bridge deck to flying bridge. Must repair to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 15 June 2022
Resolution: Picture emailed to MI...[name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2022 Resolved
All fuel lines not in service must be capped in addition to be closed. Observed one fuel line from old fuel tank not in service that was not properly capped. Must repair to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 15 June 2022
Resolution: Picture emailed to MI...[name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 June 2021 Resolved
01 Ring Life Buoy found unserviceable. Provide new Ring Life Buoy onboard.
Action required: 10 - Deficiency Rectified
Resolved 9 June 2021
Resolution: Vessel rep emailed pictures of rectified def.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 June 2021 Resolved
Navigation Anchor & STBD Light found inoperable. Show Proper operation of all Nav Lights.
Action required: 10 - Deficiency Rectified
Resolved 9 June 2021
Resolution: Vessel rep emailed pictures of rectified def.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 9 June 2021 Resolved
02 recirculation pumps were found unmounted in the Laz, properly mount both pumps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 5 July 2021
Resolution: Vessel rep emailed pictures of rectified def.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 9 June 2021 Resolved
The uppermost step to enter the Laz was found loose and unstable, properly fasten the upper step.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 5 July 2021
Resolution: Vessel rep emailed pictures of rectified def.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 June 2021 Resolved
The secondary bait pump in the engine room was wired with non-approved boat cable, re-wire pump with properly rated approved boat cable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 5 July 2021
Resolution: Vessel rep emailed pictures of rectified def.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 9 June 2021 Resolved
The sewage overboard plumbing was found with a broken hose clamp, provide flexible hose with operable hose clamp
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 5 July 2021
Resolution: Vessel rep emailed pictures of rectified def.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 9 June 2021 Resolved
The ladder to the upper deck was found loose and not properly mounted, provide ladder with properly sized fasteners and secured in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 5 July 2021
Resolution: Vessel rep emailed pictures of rectified def.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 9 June 2021 Resolved
The stbd wet exhaust penetrating the the engine room to laz bulkhead was found not to be vapor tight, make bulkhead vapor tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 5 July 2021
Resolution: Vessel rep emailed pictures of rectified def.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 June 2020 Resolved
Replace 01 condemned lifejacket found during inspection. Reduce max persons allowed to 49 until replaced and onboard.
Action required: 705 - Other - as specified
Resolved 13 July 2020
Resolution: replaced life jacket
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2020 Resolved
Vessel does not have spanner wrenches for fire stations. ensure wrenches are onboard and ready for use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2020
Resolved 13 July 2020
Resolution: Procured wrenches
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 11 June 2020 Resolved
LIFERAFT HYDROSTATIC RELEASE WAS INSTALLED INCORRECTLY.
Action required: 10 - Deficiency Rectified
Resolved 11 June 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 December 2019 Resolved
The firefighting equipment of all vessels shall be inspected & all deficiencies found shall be corrected. (02) Portable fire extinguishers found to be expended; (01) fwd berthing & (01) aft berthing port side. Vessel to have (02) extinguishers serviced, as indicated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 December 2019
Resolved 27 December 2019
Resolution: 02 fire extinguishers were replaced in-kind and serviced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 December 2019 Resolved
The MI shall examine all accessible parts of the vessel's hull, machinery, & equipment to be assured that they are in a satisfactory condition. Vessel to conduct post dry dock sea trial, as indicated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 December 2019
Resolved 27 December 2019
Resolution: Completed underway sea trial, vessel was not actively making water in any compartments. Inspected machinery while underway, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 1 February 2020
Resolved 6 February 2020
Resolution: Attended vessel to conduct spot check of A/C electrical one-line drawing, all sat. Drawing was reviewed by Sector San Diego and placed in electronic and permanent files.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 1 October 2019 Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously. Vessel has been instructed to operate with a look-out and watchman while conducting drift operations.
Action required: 10 - Deficiency Rectified
Due 1 October 2019
Resolved 1 October 2019
Resolution: Educated owner, operator, captain, and crew of the requirement to have separate watchmen and look-out while conducting drift operations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2019 Resolved
All electrical equipment must be clearly labeled marked and identified. Label all breakers on all panels for what circuit they feed.
Action required: 705 - Other - as specified
Due 1 January 2020
Resolved 27 December 2019
Resolution: All circuits were properly labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2019 Resolved
All electrical equipment should be installed to protect vessel from fire and electrical hazards. Remove 02 power strips under bridge console and supply loads with appropriate outlets.
Action required: 705 - Other - as specified
Due 1 January 2020
Resolved 27 December 2019
Resolution: Power strips were removed and outlets wired in.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2019 Resolved
Vessel must have adequate emergency lighting fitted along the line of escape for all passenger and crew accommodation spaces. Forward crew bunk room requires an additional emergency light.
Action required: 705 - Other - as specified
Due 1 January 2020
Resolved 27 December 2019
Resolution: Additional emergency lighting fixtures were installed in each stateroom.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 June 2019 Resolved
Renew wasted forward life ring.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: Life ring was replaced in-kind.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2019 Resolved
Removed dead-ended cable IWO galley fan.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: Dead ended cable was pulled back and terminated at source.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 June 2019 Resolved
Provide vessel with current version of Coast Pilot.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: Vessel was provided with current version of Coast Pilot.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 June 2019 Resolved
Properly mount fire pump, correct chafed wiring, and repair leak on piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: All corrections were made to the fire pump.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2019 Resolved
Make CO2 shut-down switch water-tight at cable penetration.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: Sealant was provided on the cable penetration.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2019 Resolved
Replace unauthorized cable for fresh water pump/motor with adequately sized boat cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: Cable was replaced proper sized boat cable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2019 Resolved
Provide missing breaker with cover in galley electrical panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: Cover was provided for electrical panel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2019 Resolved
Provide bilge pump with a guard to cover rotating parts.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: Motor was provided with cover.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 6 June 2019 Resolved
Terminate unused fuel tank piping as close to cutoff valve as possible.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: Unused fuel piping was removed and terminated after the cut-off valve.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 6 June 2019 Resolved
Provide cap for opened piping thru-hull valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: Pipe was provided with cap.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 6 June 2019 Resolved
Replace cover on electrical solenoid and remove dead ended wires in aft accommodation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: Cover was installed and wires were terminated in j-box.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 6 June 2019 Resolved
Replace missing light cover and outlet cover in aft accommodation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: Light was removed and electrical box cover was added.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2019 Resolved
Renew wasted cooling pipe on port generator.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 June 2019
Resolution: Vessel's crew removed pipe from starboard generator and installed it on port. Vessel's route reduced to zone 1 operations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2019 Resolved
Repair fuel leak on starboard generator priming pump. Do not use generator until repaired. Vessel is restricted to a zone one route until two generators are fully operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: New water pipe was installed, pipe was removed to repair wasted pipe on the port generator. New fuel priming pump was installed. Operationally tested generator, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2019 Resolved
Make generator interlock device operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: The generator interlock switch was adjusted and functioned properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2019 Resolved
Provide both main engine exhausts with proper lagging on all areas of dry piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: New lagging was professionally installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2019 Resolved
Repair cracked exhaust support bracket on port main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: Brackets were re-welded.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 6 June 2019 Resolved
Prove proper operation of lazarette bilge alarm.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 June 2019
Resolution: Vessel's crew corrected wiring issue with alarm, and proved operation.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018 Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 June 2019
Resolution: Verified in VIVS
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 June 2018 Resolved
Porvide proper mouting for for the following loosley installed items: PW head tank & piping, steering piping, helium bottle, F/O strainers, battery boxes, and bait pump.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 5 July 2018
Construction/Loadline › Structures › Manhole
Issued 6 June 2018 Resolved
Provide a keeper chain for the WTHs on deck
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 July 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 June 2018 Resolved
Provide proper install for loose/unsupported/open ended electrical wiring in the lazerette, engineroom, fwd bunkroom, storage closet fwd.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 5 July 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 May 2017 Resolved
Pneumatic switch outside of engine compartment would not shut down engine room machinery. Switch was corroded causing failure.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 9 May 2017
Resolution: New switch installed by fire technician Sergio.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 May 2017 Resolved
Provide current light list.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 13 July 2017
Resolution: Current light list provided.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 9 May 2017 Resolved
Provide current tide tables and currents
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 13 July 2017
Resolution: Tide tables provided.
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 May 2017 Resolved
Provide lids for batteries.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 9 May 2017
Resolution: Provides lids for batteries.
Fire Fighting › Fire Pumps › Capacity
Issued 9 May 2017 Resolved
Provide working gauge for fire pump.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 13 July 2017
Resolution: Gauge provided.
Documentation › Certificates/Documents › Permit, Other
Issued 7 June 2016 Resolved
Provide marine radio operators permit for each licensed master onboar.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 28 June 2016
Resolution: Marine operators permits onboard
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 June 2016 Resolved
Provide radio safetey certificate onboard the vessel
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 28 June 2016
Resolution: Radio Safety Certificate is now onboard.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 June 2016 Resolved
Renew buoyant lifeline on upper portside life ring buoy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 28 June 2016
Resolution: Life line renewed
Navigation › Piloting/Steering › Marine Charts
Issued 7 June 2016 Resolved
Provide updated charts for the operating area of the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 28 June 2016
Resolution: Updated charts provided
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 June 2016 Resolved
Provide current copy or extracts of the U.S. Coast Pilot
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 28 June 2016
Resolution: Current copy of coast pilot now onboard.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 June 2016 Resolved
Provide current copy or extracts of the Coast Light list for operating area.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 28 June 2016
Resolution: light list now onboard
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 June 2016 Resolved
Provide tide/tidal current table for the vessel's operating area.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 28 June 2016
Resolution: Tidal currents tables now onboard
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 June 2014 Resolved
Replace expired items in the first aid kit; ammonia, iodine, and burn cream.
Action required: 705 - Other - as specified
Due 1 August 2014
Resolved 9 September 2014
Resolution: Items in first aid kit were replaced
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 June 2014 Resolved
Replace masthead & stern light with UL listed lights for vessels >65'.
Action required: 705 - Other - as specified
Due 1 August 2014
Resolved 9 September 2014
Resolution: Stern light replaced and tested
Lifesaving › Lifebuoys › Serviceable
Issued 25 June 2014 Resolved
Replace forward life ring buoy
Action required: 705 - Other - as specified
Due 1 August 2014
Resolved 9 September 2014
Resolution: Forward life ring replaced
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 June 2014 Resolved
Prove proper operation of the below deck emergency lighting. (prior to overnight accommodations)
Action required: 705 - Other - as specified
Resolved 26 June 2014
Resolution: Witnessed operation of the below deck emergency lighting.
Engineering › Bilge Water Management System › Strainer
Issued 25 June 2014 Resolved
Install strainer on forward berthing bilge piping.
Action required: 705 - Other - as specified
Due 1 August 2014
Resolved 9 September 2014
Resolution: Installed strainer and tested
Engineering › Fuel Oil Service System › Valve
Issued 25 June 2014 Resolved
Provide non combustible shielding around fuel cutout valve handle in the engine room.
Action required: 705 - Other - as specified
Due 1 August 2014
Resolved 9 September 2014
Resolution: Installed non combustible shielding
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 25 June 2014 Resolved
Make fixed fire fighting system in E/R capable of automatic discharge and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2014
Resolution: Witnessed proper operation of the automatic heat detection on the fixed fire fighting system
Electrical › Electrical Distribution System (service) › Conductor
Issued 25 June 2014 Resolved
Remove all dead ended wires underneath pilothouse console.
Action required: 705 - Other - as specified
Due 1 August 2014
Resolved 9 September 2014
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 15 May 2012 Resolved
Prove proper operation of STBD generator shutdown with CO2 system activation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2012
Resolved 24 May 2012
Resolution: Proved engine will shutdown with CO2 system activation.
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 May 2012 Resolved
Conduct underway drills with CGMI.
Due 18 June 2012
Resolved 24 May 2012
Resolution: Conducted satifactory underway drills.
Electrical › Electric Supply System (service) › Cable
Issued 15 May 2012 Resolved
Provided approved wiring for fuel transfer pump.
Condition: Placed in Improper Service
Due 18 June 2012
Resolved 24 May 2012
Resolution: Installed approved wiring for fuel transfer pump.
Fire Fighting › Fire Main › Pressure
Issued 15 May 2012 Resolved
Provide working PSI guage for fire pump.
Condition: Improper/Lack of Maintenance
Due 18 June 2012
Resolved 24 May 2012
Resolution: Installed new guage.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 15 May 2012 Resolved
Provide UL approved smoke detectors for both bunk rooms.
Due 18 June 2012
Resolved 24 May 2012
Resolution: Installed new smoke detectors in both bunk rooms.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 May 2012 Resolved
Provide 36 additional Type I lifejackets to be in compliance with correct quantity required by the COI.
Due 18 June 2012
Resolved 24 May 2012
Resolution: Provide sufficient number of lifejackets to be in compliance with the COI.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 December 2009 Resolved
Drydock expired on 06 December 2009. Make vessel available for drydock and internal structural examination.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2010
Resolved 19 April 2010
Resolution: DD exam conducted, see activity # 3742137
Construction/Loadline › Hull › Hull Plating
Issued 3 June 2008 Resolved
Provide written repair proposal for damage to stem/bow area sustained on 02June2008.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 5 June 2008
Construction/Loadline › Hull › Bottom Plating
Issued 3 June 2008 Resolved
Upon completion fo repairs, have repairs inspected to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 5 June 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Connecting Rod
Issued 3 June 2008 Resolved
Replace wasted Morse Cable connection where throttle arm attaches to transmission on both P&S MDEs.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 5 June 2008
Documentation › Logs/Records › Drug Test Records
Issued 2 May 2008 Resolved
Prove crew enrollment in random drug testing program, and provide pre-enrollment test results for new crew members.
Action required: 705 - Other - as specified
Due 20 May 2008
Resolved 27 May 2008
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 14 April 2008 Resolved
Replace damaged shore tie cable.
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 2 May 2008
Engineering › Generator (propulsion-electric) › Winding
Issued 14 April 2008 Resolved
Prove proper operation of port generator.
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 2 May 2008
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 14 April 2008 Resolved
Provide flame screens for all fuel tank vents.
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 2 May 2008
Fire Fighting › Fire Pumps › Pressure
Issued 14 April 2008 Resolved
Replace fire pump pressure gauge.
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 2 May 2008
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 14 April 2008 Resolved
Renew lagging for both MDEs.
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 2 May 2008
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 April 2008 Resolved
Label remote fuel shut-off valves to indicate which fuel tanks are operated by each remote pull (due to 3 pulls at same location).
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 2 May 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 14 April 2008 Resolved
Ensure controls for fixed CO2 F/F system (pressure switches) are located outside the space protected (E/R).
Action required: 705 - Other - as specified
Due 14 October 2008
Resolved 23 December 2009
Resolution: Deficiency was duplicated and closed in activity # 3458491.
Documentation › Logs/Records › Drug Test Records
Issued 2 April 2008 Resolved
Provide current drug testing documentation.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 2 May 2008
Navigation › Piloting/Steering › US Coast Pilot
Issued 2 April 2008 Resolved
Provide current tide tables, US Coast Pilot [name withheld], and tidal current tables, or extracts.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 14 April 2008
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 2 April 2008 Resolved
Rejected (12) PFDs. Provide an additional (12) adult Type-1 PFDs.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 14 April 2008
Documentation › Certificates/Documents › Stability Letter
Issued 2 April 2008 Resolved
Post Stability Letter on bridge.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 14 April 2008
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 2 April 2008 Resolved
Post Station Bill.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 14 April 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 April 2008 Resolved
Repair high-water bilge alarm for Laz.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 14 April 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 April 2008 Resolved
Conduct and log Fire and MOB drills in presence of CG inspector.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 14 April 2008
Operations/Management › Equipment Service/Testing › EPIRB
Issued 2 April 2008 Resolved
Log EPIRB tests monthly.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 14 April 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 April 2008 Resolved
Repair mast head light, stern light, and anchor light.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 2 May 2008
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 2 April 2008 Resolved
Mark vessel name on stern.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 14 April 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 April 2008 Resolved
Remove or properly terminate exposed electrical wires on bridge.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 14 April 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 2 April 2008 Resolved
Repair/replace light cover on bridge.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 14 April 2008
Communications › Radio Communications › Satellite Communications Capability
Issued 2 April 2008 Resolved
Repair/replace NAVTEX receiver.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 14 April 2008
Fire Fighting › Structural - B Class Divisions › Windows
Issued 2 April 2008 Resolved
Replace cracked stbd side (fwd) window on bridge.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 14 May 2008
Fire Fighting › Ventilation Systems › Ducts
Issued 2 April 2008 Resolved
Provide dampers for E/R ventilation ducts.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 14 April 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 2 April 2008 Resolved
Label remote pull for E/R fixed F/F system (on deck).
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 2 May 2008
Lifesaving › Lifefloat › Markings
Issued 2 April 2008 Resolved
Re-mark vessel name and capacity on lifefloats.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 2 May 2008
Lifesaving › Lifefloat › Serviceable
Issued 2 April 2008 Resolved
Repair or replace lifefloats (where damaged) as identified.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 2 May 2008
Construction/Loadline › Structures › End Bulkhead
Issued 4 January 2008 Resolved
Repair busted shelf over rudder posts/linkage.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2008
Resolved 14 April 2008
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 4 January 2008 Resolved
Remove piping/materials stored on exhaust pipes in laz.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2008
Resolved 14 April 2008
Fire Fighting › Grease Extraction Hood › General
Issued 4 January 2008 Resolved
Install and/or modify existing grease extraction hood to meet Sector San [name withheld] Policy Ltr #20. Correct prior to using griddle and/or cooking grease laden foods onboard.
Due 4 January 2008
Resolved 1 April 2008
Construction/Loadline › Structures › Air Pipe
Issued 6 December 2007 Resolved
Replace/repair slammer tank overboard piping supports in laz.
Due 18 January 2008
Resolved 14 April 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 6 December 2007 Resolved
Repair port M/E exhaust leaks and supports, and stbd M/E exhaust lagging.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 January 2008
Resolved 14 April 2008
Construction/Loadline › Structures › Machinery Space Opening
Issued 6 December 2007 Resolved
Make fwd E/R bulkhead upper penetrations vapor/water tight.
Due 18 January 2008
Resolved 14 April 2008
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 18 September 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 13 July 2010
Resolution: Verified resolved during attendance on 12Jul10.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 18 September 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 13 July 2010
Resolution: Verified resolved during attendance on 13Jul10.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 18 September 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 13 July 2010
Resolution: Verified resolved during attendance on 13Jul10.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 11 July 2007 Resolved
CO2 line was unhooked at the tank while vessel was replacing the aft deck. Noted for operator to reinstall the system.
Condition: Improper Installation
Due 11 July 2007
Resolved 12 July 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 July 2007 Resolved
Make emergency light operable.
Condition: Improper/Lack of Maintenance
Due 11 July 2007
Resolved 12 July 2007
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 11 July 2007 Resolved
Test single side band radio to test operability.
Due 11 July 2007
Resolved 12 July 2007
Documentation › Logs/Records › Drug Test Records
Issued 11 July 2007 Resolved
Provide drug documentation for vessel crew.
Due 11 August 2007
Resolved 18 October 2007
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 11 July 2007 Resolved
Conduct and log manoverboard, fire drill and epirb test.
Due 11 August 2007
Resolved 18 October 2007
Documentation › Certificates/Documents › FCC SSL
Issued 11 July 2007 Resolved
Provide FCC station license and operator license.
Condition: Unknown
Due 11 August 2007
Resolved 18 October 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 July 2007 Resolved
Repair compass light.
Condition: Improper/Lack of Maintenance
Due 11 August 2007
Resolved 18 October 2007
Lifesaving › Buoyant Apparatus › Serviceable
Issued 11 July 2007 Resolved
For lifefloats: Fasten oars, supporting plates, capacity, holes on LF, new painter lines.
Condition: Improper/Lack of Maintenance
Due 11 August 2007
Resolved 18 October 2007
Lifesaving › Lifebuoys › Serviceable
Issued 11 July 2007 Resolved
Patch minor tear in aft ring buoy.
Due 11 August 2007
Resolved 18 October 2007
Fire Fighting › Means of Escape › Escape Route Signs
Issued 11 July 2007 Resolved
Label means of escapes and fuel shutoff.
Due 11 August 2007
Resolved 18 October 2007
Construction/Loadline › Structures › Machinery Space Opening
Issued 11 July 2007 Resolved
Provide bolts for supprting pole to overhead in ER near entry.
Due 11 August 2007
Resolved 18 October 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 July 2007 Resolved
Make all gaps at penetration in ER forward tranverse bulhead watertight.
Due 11 August 2007
Resolved 18 October 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 July 2007 Resolved
Enroll vessel captain into the vessel drug program and to provide proof of drug program enrollment in prior to sailing with passengers.
Due 11 July 2007
Resolved 12 July 2007
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 22 May 2007 Resolved
Old fuel tanks removed and new tanks being constructed. Upon completion of construction of new fuel tanks, conduct satisfactory hydro-testing prior to installation.
Action required: 705 - Other - as specified
Resolved 22 May 2007
Resolution: Conducted satisfactory hydro-testing of fuel tanks.
Stability › Incline Test › General
Issued 25 January 2006 Resolved
Post stability letter
Due 10 February 2006
Resolved 8 February 2006
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 25 January 2006 Resolved
Label aft fuel shut off.
Due 10 February 2006
Resolved 8 February 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 25 January 2006 Resolved
Provide E/R vent closures for CO2 system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2006
Resolved 8 February 2006
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 25 January 2006 Resolved
Provide list of all crewmembers enrolled in drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2006
Resolution: Operator faxed proof of drug program enrolled certification.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 25 January 2006 Resolved
Blanked off open circuit breaker bays on bridge and E/R panels.
Due 10 February 2006
Resolved 8 February 2006
Navigation › Piloting/Steering › Marine Charts
Issued 25 January 2006 Resolved
Provide currently corrected charts.
Due 8 February 2006
Resolved 8 February 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 January 2006 Resolved
Clean or replace port, stbd, and stern nav lights lens.
Due 10 February 2006
Resolved 8 February 2006
Lifesaving › Buoyant Apparatus › Lifeline
Issued 25 January 2006 Resolved
Replace water light line (3 ft.) on ring buoy. Ensure light and line are not attached on the same buoy.
Due 8 February 2006
Resolved 8 February 2006
Communications › Radio Communications › EPIRB
Issued 25 January 2006 Resolved
Conduct and log EPIRB test monthly.
Due 8 February 2006
Resolved 8 February 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 January 2006 Resolved
Provide cover for overhead light and switch in cabin A3.
Due 10 February 2006
Resolved 8 February 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 January 2006 Resolved
Removed dead ended wires under helm. Cleanup, support, and protect electrical wires under helm.
Due 10 February 2006
Resolved 16 February 2006
Stability › Watertight Integrity › General
Issued 25 January 2006 Resolved
Label bilge alarm light for forepeak and fwd berthing.
Due 10 February 2006
Resolved 8 February 2006
Construction/Loadline › Penetrations › Pipe Flange
Issued 25 January 2006 Resolved
Install metallic shut off valves on new bait tank bulkhead penetrations, both sides of the bulkheads. At the metallic bulkhead penetration, PVC pipe used on both sides. old subchapter T 46CFR 182.40-1.
Due 10 February 2006
Resolved 8 February 2006
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 25 January 2006 Resolved
Repair overhead beam on stbd side in E/R.
Due 10 February 2006
Resolved 8 February 2006
Construction/Loadline › Hull › Hull Plating
Issued 28 November 2005 Resolved
Repair/replace 7' x 4' inset on the starboardside forward section just below the waterline. Submit repair proposal after inspection by boatyard wood repair expert for review.
Action required: 705 - Other - as specified
Resolved 12 January 2006
Resolution: Repairs completed. Replaced damaged planks & re-inforced frames & stiffeners internally.
Construction/Loadline › Hull › Keel
Issued 28 November 2005 Resolved
Replace/replace sections of the worm-shoe damaged by woodborers.
Action required: 705 - Other - as specified
Resolved 12 January 2006
Resolution: Damaged sections were cut out, filled and sealed.
Construction/Loadline › Hull › Keel
Issued 28 November 2005 Resolved
Repair/re-caulk areas of the keel where cracks in the seams are exposed.
Action required: 705 - Other - as specified
Resolved 12 January 2006
Resolution: Re-caulked seems.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 15 March 2005 Resolved
Post emergency instruction placard
Due 15 April 2005
Resolved 17 March 2005
Navigation › Piloting/Steering › Marine Charts
Issued 15 March 2005 Resolved
Provide current charts, Coast Pilot [name withheld], and tide tables for area transited.
Due 15 April 2005
Resolved 12 April 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 March 2005 Resolved
Re-stock first aid kit so it meets 46CFR184.710
Due 15 April 2005
Resolved 12 April 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 15 March 2005 Resolved
Replace exhaust lagging on stbd main engine and port generator.
Due 15 April 2005
Resolved 12 April 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 March 2005 Resolved
Re-label or place a total of 10 child lifejackets in upper deck storage.
Due 15 April 2005
Resolved 17 March 2005
Fire Fighting › Fire Pumps › Gland Sealing
Issued 24 February 2005 Resolved
Repair leaking seal on fire pump.
Due 15 April 2005
Resolved 12 April 2005
Communications › Radio Communications › EPIRB
Issued 15 April 2004 Resolved
Renew hydrostatic release on EPIRB.
Due 15 May 2004
Resolved 13 May 2004
Engineering
Issued 15 April 2004 Resolved
Install guard on ventilation fans in laz.
Due 15 May 2004
Resolved 13 May 2004
Electrical › Electrical Distribution System (service) › Switch
Issued 15 April 2004 Resolved
Replace switch on brine pump control box in lazaret.
Due 15 May 2004
Resolved 13 May 2004
Electrical › Electrical Distribution System (service)
Issued 18 November 2003 Resolved
Electrical box in Stbd side lazarette was improperly used to power permanent ventilation fan allowing corrosion to build up. LEGACY COMPONENT DESC: Outlet Box
Condition: Placed in Improper Service
Due 19 December 2003
Resolved 18 December 2003
Electrical › Electrical Distribution System (service)
Issued 18 November 2003 Resolved
Non marine grade outlet box was installed in lazarette centerline resulting in heavy corosion. Box needs to be renewed with marine grade materials (with protective covering.) LEGACY COMPONENT DESC: Outlet Box
Condition: Design Flaw
Due 19 December 2003
Resolved 18 December 2003
Electrical › Electrical Distribution System (service)
Issued 18 November 2003 Resolved
There is no cover on the junction box in the lazarette centerline overhead. LEGACY COMPONENT DESC: Junction Box
Condition: Design Flaw
Due 19 December 2003
Resolved 18 December 2003
Construction/Loadline › Penetrations
Issued 18 November 2003 Resolved
there is currently a PVC pipe penetration through the watertight bulkhead. Penetration must be removed and a metal through fitting installed with metal valves on both sides prior to resuming PVC piping. LEGACY COMPONENT DESC: Pipe Flange
Condition: Design Flaw
Due 19 December 2003
Resolved 2 February 2004
Resolution: Approved waiver request
Electrical › Electric Generation Source (service)
Issued 10 January 2003 Resolved
Port generator windings need to be cleaned. IAW 46 CFR 183.200 LEGACY COMPONENT DESC: Generator
Due 24 January 2003
Resolved 14 February 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 10 January 2003 Resolved
Galley hood needs to be cleaned. IAW 46 CFR 183.200
Due 24 January 2003
Resolved 14 February 2003
Lifesaving › Buoyant Apparatus
Issued 10 January 2003 Resolved
stacked life floats require spacers to seperate floats. IAW 46 CFR 180.137 (f) LEGACY COMPONENT DESC: Life Floats
Due 24 January 2003
Resolved 14 February 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 10 January 2003 Resolved
Emergency escape hatches must be marked as such, and each hatch must have a handle. IAW 46 CFR 177.500 and 185.606
Due 24 January 2003
Resolved 14 February 2003
Operations/Management › Passenger Operations
Issued 10 January 2003 Resolved
Windows which are cracked/broken on Bridge and in accomodation space Fwd. and Amidships Port side must be replaced. IAW 46 CFR 177.1020 and 1030 LEGACY COMPONENT DESC: Broken windows
Due 24 January 2003
Resolved 14 February 2003
Lifesaving › Rescue Boat
Issued 10 January 2003 Resolved
Provide suitable rescue boat or rescue ladder with stand offs or to the satisfaction of the Coast Guard Inspector. IAW 46 CFR 180.210 LEGACY COMPONENT DESC: Rescue boat or ladder
Due 24 January 2003
Resolved 14 February 2003
Construction/Loadline › Structures
Issued 23 May 2002 Resolved
Submit detailed repair proposal for repairs to vessel. these are to include materials, work processes and a time line to complete repairs. Any new systems that are to be installed are to include drawings. Plans and repairs are to be approved by the MSO San Diego inspections department.
Condition: Damaged By Earlier Event
Due 15 July 2002
Resolved 15 July 2002
Documentation › Certificates/Documents
Issued 15 April 2002 Resolved
Provide FCC station license IAW 47CFR 80.13 LEGACY COMPONENT DESC: FCC SSL
Due 1 May 2002
Resolved 29 April 2002
Navigation › Collision/Grounding Avoidance
Issued 15 April 2002 Resolved
Provide operational anchor light that works independent of navigation lights. LEGACY COMPONENT DESC: Navigation Lights
Due 1 May 2002
Resolved 29 April 2002
Lifesaving › Lifejacket/PFD (General)
Issued 15 April 2002 Resolved
Replace retro on adult PFD's as necessary IAW 46 CFR 185.604 (h). LEGACY COMPONENT DESC: Retroreflective Material
Due 1 May 2002
Resolved 29 April 2002
Electrical › Lighting (service)
Issued 15 April 2002 Resolved
Remove light/electrical fixtures not in use in lazarette, bunk room and forepeak. LEGACY COMPONENT DESC: Lighting Fixture
Due 1 May 2002
Resolved 29 April 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 15 April 2002 Resolved
Replace expired items in first aid kit. LEGACY COMPONENT DESC: First Aid Kit
Due 1 May 2002
Resolved 29 April 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 15 April 2002 Resolved
Clean galley exhaust vents LEGACY COMPONENT DESC: Exhaust Vents
Due 1 May 2002
Resolved 29 April 2002
Construction/Loadline › Structures
Issued 15 April 2002 Resolved
Provide water tight integrity for water tight bulkhead between bunk rooms. LEGACY COMPONENT DESC: Transverse Bulkhead
Due 1 May 2002
Resolved 29 April 2002
Electrical › Electrical Distribution System (service)
Issued 15 April 2002 Resolved
Provide covers for circuit breaker panels and mark circuit breakers with corresponding use. LEGACY COMPONENT DESC: Circuit Breaker
Due 1 May 2002
Resolved 15 April 2002
Electrical › Electrical Distribution System (service)
Issued 15 April 2002 Resolved
Remove twist-on electrical connectors and provide correct butt connectors IAW 46 CFR 183.432 LEGACY COMPONENT DESC: Wiring
Due 1 May 2002
Resolved 29 April 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 15 April 2002 Resolved
Provide serviced portable fire extinguishers IAW 46 CFR 176.810, NFPA 10 Chap 4. LEGACY COMPONENT DESC: Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2002
Resolved 29 April 2002
Stability › Unintentional Flooding
Issued 15 April 2002 Resolved
Provide audible alarm on bridge for forepeak bilge alarm. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2002
Resolved 29 April 2002
Engineering › Fuel Oil Service System
Issued 15 April 2002 Resolved
Provide proposal for aft fuel tank (gauging, material used, original thickness, possible removal from service, etc.). LEGACY COMPONENT DESC: Tank
Due 1 May 2002
Resolved 29 April 2002
Documentation › Certificates/Documents
Issued 15 April 2002 Resolved
Remove expired COI from being posted. LEGACY COMPONENT DESC: Certificate of Inspection
Due 1 May 2002
Resolved 29 April 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 15 April 2002 Resolved
Provide Ultra-Sonic test results of metal thickness on aft fuel tank. Provide at least three shots, top, middle and bottom, and side if possible. The results will determine if repair proposal is sufficient. LEGACY COMPONENT DESC: Tank
Condition: Unknown
Due 10 May 2002
Resolved 8 May 2002
Documentation
Issued 9 December 1999 Resolved
Comply w/ chemical (drug) testing program and demonstrate to inspector.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Lifesaving
Issued 9 December 1999 Resolved
Prior to taking on passengers, provide proper number of life jackets per COI. All life jackets to be properly marked and stowed.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Engineering
Issued 9 December 1999 Resolved
Label remotely operated fuel valves prior to 24 DEC 99.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Navigation
Issued 17 November 1999 Resolved
NOTIFY MARINE INSPECTION OFFICE WHEN STEERING GEAR IS INSTALLED, REQUIRES EXAMINATION OF STEERING SYSTEM.
Condition: Unknown
Due 1 December 1999
Resolved 22 November 1999
Construction/Loadline
Issued 17 November 1999 Resolved
REPLACE DECK PLYWOOD AND SUPPORTS IN WAY OF STARBOARD SIDE EMBARKATION AREA, MAIN DECK.
Condition: Unknown
Due 1 December 1999
Resolved 22 November 1999
Construction/Loadline
Issued 17 November 1999 Resolved
PREPARE WRITTEN REPAIR PROPOSAL FOR ENSURING STRUCTURAL INTEGRITY OF E/R OVERHEAD BEAM/SUPPORT (IN VICINITY OF EXHAUST).
Condition: Unknown
Due 1 December 1999
Resolved 22 November 1999
Electrical
Issued 26 August 1999 Resolved
Bilge pump controller in engine room, cover not installed.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Fire Fighting
Issued 26 August 1999 Resolved
Fire pump pressure gauge not operational, replace gauge & test to the satisfaction of [name withheld] diego
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Fire Fighting
Issued 26 August 1999 Resolved
lable remote fire pump controller.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Fire Fighting
Issued 26 August 1999 Resolved
Lable remote pull station for engine room fixed system
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Fire Fighting
Issued 26 August 1999 Resolved
Install ventilation ducts closers for engine room air intakes, to the satisfaction of [name withheld].
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Fire Fighting
Issued 26 August 1999 Resolved
Fire extinguisher in engine room not mounted in holding bracket.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Fire Fighting
Issued 26 August 1999 Resolved
Complete Installation & conduct final inspection & test of sysytem to the satisfaction of [name withheld].
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Engineering
Issued 18 May 1999 Resolved
Renew Morrris control cable for MDE (cable broken on Port Bridge Control Station).
Condition: Unknown
Due 1 June 1999
Resolved 13 August 1999
Documentation
Issued 18 May 1999 Resolved
Provide a copy of EPIRB registration.
Condition: Unknown
Due 1 June 1999
Resolved 13 August 1999
Accommodation/Occupational Safety
Issued 18 May 1999 Resolved
Renew STBD Head window (main deck).
Condition: Unknown
Due 1 June 1999
Resolved 13 August 1999
Accommodation/Occupational Safety
Issued 18 May 1999 Resolved
Renew Exhaust Vent Covers in FWD Bunk Rooms A-2 - A-3.
Condition: Unknown
Due 1 June 1999
Resolved 13 August 1999
Fire Fighting
Issued 18 May 1999 Resolved
Install Fixed Fire Fighting System in Engine Room.
Condition: Unknown
Due 1 June 1999
Resolved 13 August 1999
Fire Fighting
Issued 18 May 1999 Resolved
Test Fixed Fire fighting system in Engineroom.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Lifesaving
Issued 18 May 1999 Resolved
Install Bilge Alarm in FWD Peak Tank.
Condition: Unknown
Due 1 June 1999
Resolved 13 August 1999
Engineering
Issued 18 May 1999 Resolved
Provide Report addressing condition of Port Gear Drive High Transmission Temperature from Technical Rep.
Condition: Unknown
Due 1 June 1999
Resolved 13 August 1999
Electrical
Issued 18 May 1999 Resolved
Provide weight specifications for old & new Diesel Generator.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Electrical
Issued 18 May 1999 Resolved
Perform operational Test of STBD Ship Service Diesel Generator.
Condition: Unknown
Due 1 June 1999
Resolved 13 August 1999
Engineering
Issued 20 October 1996 Resolved
PROPERLY REMOVE DIESEL OIL FROM AFT VOID BILGE AND LOCATE AND PROPERLY REPAIR FUEL OIL LEAK.
Condition: Unknown
Due 24 October 1996
Resolved 24 October 1996
Construction/Loadline
Issued 20 October 1996 Resolved
PROPERLY REMOVE EXCESSIVE BILGE OIL IN THE BILGES LOCATED IN WAY OF MAIN ENGINE COMPARTMENT.
Condition: Unknown
Due 24 October 1996
Resolved 24 October 1996
Engineering
Issued 20 October 1996 Resolved
SHOW PROPER OPERATION OF PORT MAIN DIESEL ENGINE.
Condition: Unknown
Due 24 October 1996
Resolved 24 October 1996
Lifesaving
Issued 20 October 1996 Resolved
SHOW PROPER OPERATION OF ALL FIVE WATERLIGHTS LOCATED ABOVE THE PILOTHOUSE FOR THE LIFE FLOATS.
Condition: Unknown
Due 24 October 1996
Resolved 24 October 1996
Lifesaving
Issued 21 November 1995 Resolved
Conduct satisfactory underway man overboard drill in the presence of a USCGmarine inspector.
Condition: Unknown
Due 21 December 1995
Resolved 29 December 1995
Construction/Loadline
Issued 21 November 1995 Resolved
Complete repairs/installation of bilge pump & piping system and demonstratesatisfactory operation to a USCG inspector. _x001C_
Condition: Unknown
Due 21 December 1995
Resolved 29 December 1995
Documentation
Issued 22 November 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 November 1994
Resolved 22 November 1994
Electrical
Issued 22 November 1994 Resolved
INSUFFICIENT EMERGENCY LIGHTING IN BERTHING AREAS.
Condition: Unknown
Due 22 November 1994
Resolved 22 November 1994
Construction/Loadline
Issued 17 December 1993 Resolved
ISSUED REQMNT TO EFFECT PERM REPAIRS IN WAY OF STBD SIDE, MIDHIPS, TO ALL UNDER DECK FRAMING AND SUPPORTS. BUTCH HARRIS, MASTER SUBMITTED LIMITED ROUTE AND REPAIR PROPOSAL TO BE EFFECTED YARD AVAILABILITY APRIL 94.
Condition: Unknown
Due 17 December 1993
Resolved 17 December 1993
Lifesaving
Issued 17 December 1993 Resolved
17 ITEM WORKLIST ISSUED FOR VESSEL 16 DEC 93. VESSEL CLEARED 16 ITEMS AND WAS ISSUED CG 835 FOR 17TH. THIS DESCREPANCY DRAFTED TO DOCUMENT WORKLIST. DETAILS ARE IN V-FILE.
Condition: Unknown
Due 28 December 1993
Resolved 28 December 1993
Construction/Loadline
Issued 22 January 1992 Resolved
REPLACE BROKEN WINDOWS IN PILOT HOUSE
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Navigation
Issued 22 January 1992 Resolved
RE-ATTACH STARBOARD RADIO ANTENNA.
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Lifesaving
Issued 22 January 1992 Resolved
REPLACE LIFE FLOAT GRAB LINES 100%
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Accommodation/Occupational Safety
Issued 22 March 1991 Resolved
REPAIR DAMAGED TRANSOM RAIL AS ORIGINAL BEFORE CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 March 1991
Resolved 22 March 1991
Unknown
Issued 22 January 1991 Resolved
CLEAN ENGINEROOM BILGES FREE OF FUEL OIL, OIL AND WATER MIXTURES PRIOR _x001C_ TO CARRYING PASSENGERS ON BOARD. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Engineering
Issued 22 January 1991 Resolved
REPAIR INOPERABLE PORT MAIN PROPULSION ENGINE. ENGINE HAS CRACKED CYLINDER_x001C_HEAD AND THREE PISTON HOLED CAUSED BY A FAULTY EXHAUST VALVES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Electrical
Issued 15 January 1991 Resolved
REPAIR STARBOARD GENERATOR AND CONDUCT SATISFACTORY OPERATIONAL TESTING _x001C_ WITH LOAD. VESSEL RESTRICTED FOR OPERATING ON OCEAN ROUTE UNTIL GENERATOR _x001C_IS SATISFACTORY OPERATING. _x001C_ _x001C_
Condition: Unknown
Due 15 January 1991
Resolved 15 January 1991
Electrical
Issued 15 January 1991 Resolved
REPAIR INOPERABLE VOLTMETER, AMP METER AND FREQUENCY METER FOR THE SHIP _x001C_ SERVICE GENERATORS. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 January 1991
Resolved 15 January 1991
Fire Fighting
Issued 15 January 1991 Resolved
REPLACE INOPERABLE DISCHARGE PRESSURE GAUGE FOR THE FIRE PUMP. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 January 1991
Resolved 15 January 1991
Lifesaving
Issued 20 December 1989 Resolved
PROVIDE ONE ADDITIONAL CHILD-SIZE LIFE PRESERVER WITH LIGHT.
Condition: Unknown
Due 20 December 1989
Resolved 20 December 1989
Navigation
Issued 20 December 1989 Resolved
PROVIDE SIX ORANGE HAND HELD FLARES.
Condition: Unknown
Due 20 December 1989
Resolved 20 December 1989
Navigation
Issued 20 December 1989 Resolved
PROVIDE THREE BLACK BALL DAY SHAPES.
Condition: Unknown
Due 20 December 1989
Resolved 20 December 1989
Unknown
Issued 20 December 1989 Resolved
PUMP DOWN/REMOVE EXCESSIVE OIL IN THE ENGINEROOM BILGES PRIOR TO PLACING VESSEL IN OPERATION.
Condition: Unknown
Due 20 December 1989
Resolved 20 December 1989
Electrical
Issued 20 December 1989 Resolved
REPAIR AND CONDUCT OPERATIONAL TEST TO PORT GENERATOR PRIOR TO PLACING VESSEL IN OPERATION.
Condition: Unknown
Due 20 December 1989
Resolved 20 December 1989
Engineering
Issued 20 December 1989 Resolved
REPAIR TACHOMETER FOR THE PORT MAIN PROPULSION ENGINE.
Condition: Unknown
Due 20 December 1989
Resolved 20 December 1989
Construction/Loadline
Issued 20 December 1989 Resolved
PROVIDE CAPTURE CHAIN FOR EACH OF THE DECK HATCHES.
Condition: Unknown
Due 20 December 1989
Resolved 20 December 1989
Fire Fighting
Issued 20 December 1989 Resolved
REPAIR LEAKING CUT-OFF VALVE TO PORT FIRE MAIN STATION.
Condition: Unknown
Due 20 December 1989
Resolved 20 December 1989
Fire Fighting
Issued 20 December 1989 Resolved
TEST STARBOARD FIRE MAIN STATION PRIOR TO PLACING VESSEL IN OPERATION.
Condition: Unknown
Due 20 December 1989
Resolved 20 December 1989
Fire Fighting
Issued 20 December 1989 Resolved
INSTALL A DISCHARGE PRESSURE GAUGE ON THE FIRE PUMP.
Condition: Unknown
Due 20 December 1989
Resolved 20 December 1989
Fire Fighting
Issued 7 December 1988 Resolved
PROVIDE VENT COVERS TO NATURAL VENTILATION EXHAUST AND INTAKE OF THE ENGINE ROOM IN WAY OF MAIN DECK.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Navigation
Issued 7 December 1988 Resolved
PROVIDE CURRENT TIDE TABLES ON BOARD.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Unknown
Issued 7 December 1988 Resolved
PROVIDE FLAME SCREEN TO FUEL OIL VENT STARBOARD SIDE AMIDSHIP.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Unknown
Issued 7 December 1988 Resolved
PROVIDE SAFETY RELIEF VALVE TO HOT WATER HEATER TANK.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Unknown
Issued 7 December 1988 Resolved
PROVIDE METALLIC TRASH CANS WITH COVER IN WAY OF LOUNGE AREA BELOW THE MAINDECK TO REPLACE PLASTIC TRASH CONTAINERS.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Unknown
Issued 7 December 1988 Resolved
PROVE PROPER OPERATION OF THE VALVE TO THE BILGE PIPING AFT OF COLLISION BULKHEAD.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Engineering
Issued 17 December 1987 Resolved
INSTALL PROTECTIVE GUARDS ON ROTATING COUPLING ON TWO (2) ELECTRIC BILGE PUMPS.
Condition: Unknown
Due 17 December 1987
Resolved 17 December 1987
Electrical
Issued 17 December 1987 Resolved
REPLACE MISSING COVER ON MAIN ELECTRICAL DISTRIBUTION PANEL.
Condition: Unknown
Due 17 December 1987
Resolved 17 December 1987
Navigation
Issued 17 December 1987 Resolved
COMPLETE INSTALLATION OF THE NEW MANUAL HYDRAULIC STEERING SYSTEM AND TEST FOR SATISFACTORY OPERATION IN THE PRESENCE OF A CG MARINE INSPECTOR PRIOR TO PLACING VESSEL IN OPERATION.
Condition: Unknown
Due 17 December 1987
Resolved 17 December 1987
Navigation
Issued 17 December 1987 Resolved
REPAIR INOPERABLE RADAR PRIOR TO PLACING VESSEL IN OPERATION.
Condition: Unknown
Due 17 December 1987
Resolved 17 December 1987
Engineering
Issued 30 December 1986 Resolved
INSTALL LOW LUBE OIL ALARMS IN BRIDGE FOR PORT AND STARBOARD MAIN ENGINES.
Condition: Unknown
Due 30 December 1986
Resolved 30 December 1986
Lifesaving
Issued 30 December 1986 Resolved
INSTALL WEAKLINK FOR LIFEFLOAT CAPACITY OF 21 PERSONS OR MORE; LIFEFLOAT LOCATED ON ROOF BRIDGE.
Condition: Unknown
Due 30 December 1986
Resolved 30 December 1986
Accommodation/Occupational Safety
Issued 25 January 1985 Resolved
INSTALL TWO MSD HOLDING TANKS OF PROPER TYPE IN EXISTING SYSTEM AT NEXT DRYDOCK EXAM IN FEB 85.
Condition: Unknown
Due 25 January 1985
Resolved 25 January 1985
Fire Fighting
Issued 11 January 1985 Resolved
REPAIR FIRE PUMP.
Condition: Unknown
Due 11 January 1985
Resolved 11 January 1985
Electrical
Issued 11 January 1985 Resolved
REPAIR EMERGENCY LIGHTING SYSTEM.
Condition: Unknown
Due 11 January 1985
Resolved 11 January 1985
Construction/Loadline
Issued 11 January 1985 Resolved
MAKE FORWARD ER BULKHEAD WATERTIGHT INBILGE AREA.
Condition: Unknown
Due 11 January 1985
Resolved 11 January 1985
Engineering
Issued 11 January 1985 Resolved
INSTALL ONE ADDITIONAL POWER BILGE PUMP.
Condition: Unknown
Due 11 January 1985
Resolved 11 January 1985

Casualty record · 8

15 May 2002Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 1719787
23 July 2006Routine · role: Involved in a Marine Investigation (non-casualty) · 1 injured · activity 2739284
1 June 2008Routine · role: Involved in a Marine Casualty · activity 3322808
7 July 2008Routine · role: Involved in a Marine Casualty · activity 3263811
7 August 2013Routine · role: Involved in a Marine Casualty · activity 4745077
21 August 2013Routine · role: Involved in a Marine Casualty · activity 4693541
9 October 2020Routine · role: Involved in a Marine Casualty · activity 7115190
22 April 2023Routine · role: Involved in a Marine Casualty · activity 7686287
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CHEROKEE GEISHA (2002–2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.