OLD GLORY

OLD GLORY is a 1968 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 2016, most recently in July 2026, along with 82 deficiencies, 1 operational control and 8 casualty investigations between 2002 and 2023.

Records from 2002 to 2026. Most recent: inspection, 15 July 2026.

Built
1968
Last inspected
15 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 July 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH5594
Flag
UNITED STATES
Maury page id
psix-45910

Documentation record

Registered dimensions (L × B × D)79.5 ft × 21.1 ft × 8.0 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA BOAT COMPANY · COSTA MESA, CA, UNITED STATES · built 1968
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 27 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 25

15 July 2026 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8439538
13 May 2026 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8354257
1 May 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8127059
9 April 2025 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8108493
27 June 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7946360
13 June 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7713963
13 June 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7883557
22 April 2023 Drydock Exam · Deficiency Check · Damage Survey · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7674856
22 April 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7686287
29 April 2022 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7440871
26 January 2022 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7386298
1 December 2021 Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7360791
9 June 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7219745
9 October 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7115190
11 June 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6973777
27 December 2019 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6879115
18 December 2019 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6872845
1 October 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6825757
6 June 2019 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6705464
11 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6537789
6 June 2018 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6435836
5 December 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6318551
9 May 2017 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6131815
7 June 2016 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5900023
7 January 2016 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5792859

Deficiency record · 82

02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 15 July 2026 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel hit a buoy which cause damage to the bow of the vessel. Submit repair plan to local OCMI for approval.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2026
Resolution: Vessel completed repairs in Santa Barbara. All SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2026 Resolved
Nothing in this subpart limits the marine inspector from conducting such tests or inspections he or she deems necessary to be assured of the vessel’s seaworthiness. During emergency dry-dock MI discovered excessive pitting on both props. Have props replaced or repaired in accordance with regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2026
Resolved 11 August 2026
Resolution: Received photos of new props installed. All SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2026 Resolved
On a vessel of not more that 65 feet in length carrying more than 49 passengers, and on a vessel of more than 65 feet in length, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure on not less than 60 PSI at the pump outlet. Fire pump was not putting out required pressure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2026
Resolution: Fire pump was capable of meeting required pressure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2026 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve was hard to operate due to cracked shielding.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2026
Resolution: Fuel Shutoff valve moved freely
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2026 Resolved
Electrical equipment on a vessel must be installed to protect the vessel from electrical hazards, including fire. Breaker box in E/R, Portside, FWD was not secured. Secure panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 1 June 2026
Resolution: MI attended vessel All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2026 Resolved
Electrical equipment on a vessel must be installed to protect the vessel from electrical hazards, including fire. Dead-end wires were found in main bunk room, A/C room, Main S/B plug socket, outside operating station and under wheel house. Remove or properly enclose them and update electrical drawing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 1 June 2026
Resolution: MI attended vessel All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2026 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Anchor light was inoperable. Provide navigation lights that are in compliance with the Navigation Rules.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 1 June 2026
Resolution: MI attended vessel All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2026 Resolved
Water lights should be serviceable and batteries replaced annually if not marked with an expiration date. Water light's were inoperable on 16 adult life jackets and 1 child's life jackets. Provide serviceable water light and replace battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 1 June 2026
Resolution: MI attended vessel All SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2025
Resolved 19 May 2025
Resolution: Received picture of the new station license.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 May 2025 Resolved
Vessel's rescue ladder is too short. Replace or modify the vessel's rescue ladder so that it is long enough to account for the vessel's maximum freeboard, to the satisfaction of the attending USCG marine inspector. Cite: 46 CFR 180.210.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2025
Resolved 16 May 2025
Resolution: A rung was added to the bottom of the ladder using heavy line and an aluminum step.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 May 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. STBD generator was leaking oil from oil filter. Replace or prove oil leak has been corrected. Cite: 46 CFR 182.100.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2025
Resolved 16 May 2025
Resolution: Leak was corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. STBD shaft seal was leaking excessively into bilge. Cite: 46 CFR 182.100.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2025
Resolved 16 May 2025
Resolution: Seal was tightened. A minor leak still exists but is within acceptable limits.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Batteries in aft engine room on portside showed corrosion on the battery terminal. Clean battery terminal back to original state. Cite: 46 CFR 183.200.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2025
Resolved 16 May 2025
Resolution: Battery terminals were cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found on portside in engine room compartment. Remove dead end wiring and update electrical plans. Cite: 46 CFR 183.200(c).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2025
Resolved 16 May 2025
Resolution: Dead end wire was removed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 May 2025 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Laz bilge alarm light is not operational at operating station. Fix light at operating station. Cite: 46 CFR 182.530(a).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2025
Resolved 19 May 2025
Resolution: Received picture of the bilge alarm light operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 May 2025 Resolved
As stated in letter dated 21MAR2024, vessel must comply with Fire Safety of Small Passenger Vessels Interim Final Rule requirements by the next scheduled dry dock or 01JAN2026, whichever comes first. Vessel does not yet meet requirements. When carrying more than 6 passengers, vessel is restricted from carrying overnight passengers or allowing passengers in the bunk rooms. National Defense Authorization Act for Fiscal Year 2024 (H.R. 2670), Section 3531(b)
Action required: 705 - Other - as specified
Resolved 13 May 2025
Resolution: Witnessed satisfactory egress drills. Final IFR compliance letter to be issued shortly.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 June 2024 Resolved
One of the vessel's integrated fire detectors is making false alarms. Repair/replace the affected detector and complete a satisfactory test in front of a USCG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2024
Resolution: Detector was replaced and tested all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 June 2024 Resolved
Steering ram connection bolt was found to be excessively loose. Tighten the affected bolt.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2024
Resolution: Bolt was tightened.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 June 2024 Resolved
Vessel's liferafts hydrostatic releases are expired. Acquire and install new hydrostatic releases for the rafts.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2024
Resolution: New hydros were acquired and installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 June 2024 Resolved
Vessel does not have evidence of a valid FCC Radiotelephony Safety Certificate or FCC Station Licese. Provide evidence of the valid certificates. This deficiency is to be rectified by 11 July 2024.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 16 July 2024
Resolution: Received scan of new certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2023 Resolved
Distribution panel IWO port side Lazarette space found to be missing blanks. Install blanks in panel to prevent shock hazard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 June 2023
Resolution: Installed Blanks
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 June 2023 Resolved
Vessel found to be missing servicing records for Gaylord extinguishing system in the galley. Provide proof of annual service to Coast Guard inspectors.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 June 2023
Resolution: Provided service records
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 April 2023 Resolved
Vessel's starboard shaft snapped while underway. Replace damaged shaft, and draw port shaft for examination by USCG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2023
Resolution: Newly fabricated shafts were installed and satisfactory sea trials were conducted on this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2022 Resolved
Exhaust gas must not leak from the piping or any connections. Observed wet exhaust leak on starboard main wet exhaust piping. Must repair to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 15 June 2022
Resolution: Picture emailed to MI...[name withheld]
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 April 2022 Resolved
Each distribution panel or switchboard must be totally enclosed. Observed two (2) inch opening on the right side of the main switchboard. Must repair to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 15 June 2022
Resolution: Picture sent to MI...[name withheld]
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 April 2022 Resolved
High Pressure CO2 fixed gas system piping, valves, and fittings must be securely supported, and where necessary, protected against damage. Observed unsupported four (4) foot un-supported section of CO2 piping in engine space. Must repair to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 15 June 2022
Resolution: Picture sent to MI...[name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 April 2022 Resolved
The fire pump outlet must be fitted with a pressure gauge. Observed pressure gauge without protected cover over analog reader. Must repair to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 15 June 2022
Resolution: Picture sent to MI...[name withheld]
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 29 April 2022 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. No flamescreen was installed on the vent pipe end from the fuel tank. Must repair to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 15 June 2022
Resolution: Picture sent to MI...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 29 April 2022 Resolved
All observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Observed missing ladder rung from 01 nav bridge deck to flying bridge. Must repair to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 15 June 2022
Resolution: Picture emailed to MI...[name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2022 Resolved
All fuel lines not in service must be capped in addition to be closed. Observed one fuel line from old fuel tank not in service that was not properly capped. Must repair to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 15 June 2022
Resolution: Picture emailed to MI...[name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 June 2021 Resolved
01 Ring Life Buoy found unserviceable. Provide new Ring Life Buoy onboard.
Action required: 10 - Deficiency Rectified
Resolved 9 June 2021
Resolution: Vessel rep emailed pictures of rectified def.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 June 2021 Resolved
Navigation Anchor & STBD Light found inoperable. Show Proper operation of all Nav Lights.
Action required: 10 - Deficiency Rectified
Resolved 9 June 2021
Resolution: Vessel rep emailed pictures of rectified def.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 9 June 2021 Resolved
02 recirculation pumps were found unmounted in the Laz, properly mount both pumps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 5 July 2021
Resolution: Vessel rep emailed pictures of rectified def.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 9 June 2021 Resolved
The uppermost step to enter the Laz was found loose and unstable, properly fasten the upper step.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 5 July 2021
Resolution: Vessel rep emailed pictures of rectified def.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 June 2021 Resolved
The secondary bait pump in the engine room was wired with non-approved boat cable, re-wire pump with properly rated approved boat cable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 5 July 2021
Resolution: Vessel rep emailed pictures of rectified def.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 9 June 2021 Resolved
The sewage overboard plumbing was found with a broken hose clamp, provide flexible hose with operable hose clamp
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 5 July 2021
Resolution: Vessel rep emailed pictures of rectified def.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 9 June 2021 Resolved
The ladder to the upper deck was found loose and not properly mounted, provide ladder with properly sized fasteners and secured in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 5 July 2021
Resolution: Vessel rep emailed pictures of rectified def.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 9 June 2021 Resolved
The stbd wet exhaust penetrating the the engine room to laz bulkhead was found not to be vapor tight, make bulkhead vapor tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 5 July 2021
Resolution: Vessel rep emailed pictures of rectified def.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 June 2020 Resolved
Replace 01 condemned lifejacket found during inspection. Reduce max persons allowed to 49 until replaced and onboard.
Action required: 705 - Other - as specified
Resolved 13 July 2020
Resolution: replaced life jacket
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2020 Resolved
Vessel does not have spanner wrenches for fire stations. ensure wrenches are onboard and ready for use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2020
Resolved 13 July 2020
Resolution: Procured wrenches
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 11 June 2020 Resolved
LIFERAFT HYDROSTATIC RELEASE WAS INSTALLED INCORRECTLY.
Action required: 10 - Deficiency Rectified
Resolved 11 June 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 December 2019 Resolved
The firefighting equipment of all vessels shall be inspected & all deficiencies found shall be corrected. (02) Portable fire extinguishers found to be expended; (01) fwd berthing & (01) aft berthing port side. Vessel to have (02) extinguishers serviced, as indicated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 December 2019
Resolved 27 December 2019
Resolution: 02 fire extinguishers were replaced in-kind and serviced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 December 2019 Resolved
The MI shall examine all accessible parts of the vessel's hull, machinery, & equipment to be assured that they are in a satisfactory condition. Vessel to conduct post dry dock sea trial, as indicated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 December 2019
Resolved 27 December 2019
Resolution: Completed underway sea trial, vessel was not actively making water in any compartments. Inspected machinery while underway, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 1 February 2020
Resolved 6 February 2020
Resolution: Attended vessel to conduct spot check of A/C electrical one-line drawing, all sat. Drawing was reviewed by Sector San Diego and placed in electronic and permanent files.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 1 October 2019 Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously. Vessel has been instructed to operate with a look-out and watchman while conducting drift operations.
Action required: 10 - Deficiency Rectified
Due 1 October 2019
Resolved 1 October 2019
Resolution: Educated owner, operator, captain, and crew of the requirement to have separate watchmen and look-out while conducting drift operations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2019 Resolved
All electrical equipment must be clearly labeled marked and identified. Label all breakers on all panels for what circuit they feed.
Action required: 705 - Other - as specified
Due 1 January 2020
Resolved 27 December 2019
Resolution: All circuits were properly labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2019 Resolved
All electrical equipment should be installed to protect vessel from fire and electrical hazards. Remove 02 power strips under bridge console and supply loads with appropriate outlets.
Action required: 705 - Other - as specified
Due 1 January 2020
Resolved 27 December 2019
Resolution: Power strips were removed and outlets wired in.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2019 Resolved
Vessel must have adequate emergency lighting fitted along the line of escape for all passenger and crew accommodation spaces. Forward crew bunk room requires an additional emergency light.
Action required: 705 - Other - as specified
Due 1 January 2020
Resolved 27 December 2019
Resolution: Additional emergency lighting fixtures were installed in each stateroom.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 June 2019 Resolved
Renew wasted forward life ring.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: Life ring was replaced in-kind.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2019 Resolved
Removed dead-ended cable IWO galley fan.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: Dead ended cable was pulled back and terminated at source.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 June 2019 Resolved
Provide vessel with current version of Coast Pilot.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: Vessel was provided with current version of Coast Pilot.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 June 2019 Resolved
Properly mount fire pump, correct chafed wiring, and repair leak on piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: All corrections were made to the fire pump.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2019 Resolved
Make CO2 shut-down switch water-tight at cable penetration.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: Sealant was provided on the cable penetration.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2019 Resolved
Replace unauthorized cable for fresh water pump/motor with adequately sized boat cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: Cable was replaced proper sized boat cable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2019 Resolved
Provide missing breaker with cover in galley electrical panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: Cover was provided for electrical panel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2019 Resolved
Provide bilge pump with a guard to cover rotating parts.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: Motor was provided with cover.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 6 June 2019 Resolved
Terminate unused fuel tank piping as close to cutoff valve as possible.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: Unused fuel piping was removed and terminated after the cut-off valve.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 6 June 2019 Resolved
Provide cap for opened piping thru-hull valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: Pipe was provided with cap.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 6 June 2019 Resolved
Replace cover on electrical solenoid and remove dead ended wires in aft accommodation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: Cover was installed and wires were terminated in j-box.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 6 June 2019 Resolved
Replace missing light cover and outlet cover in aft accommodation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: Light was removed and electrical box cover was added.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2019 Resolved
Renew wasted cooling pipe on port generator.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 June 2019
Resolution: Vessel's crew removed pipe from starboard generator and installed it on port. Vessel's route reduced to zone 1 operations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2019 Resolved
Repair fuel leak on starboard generator priming pump. Do not use generator until repaired. Vessel is restricted to a zone one route until two generators are fully operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: New water pipe was installed, pipe was removed to repair wasted pipe on the port generator. New fuel priming pump was installed. Operationally tested generator, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2019 Resolved
Make generator interlock device operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: The generator interlock switch was adjusted and functioned properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2019 Resolved
Provide both main engine exhausts with proper lagging on all areas of dry piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: New lagging was professionally installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2019 Resolved
Repair cracked exhaust support bracket on port main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: Brackets were re-welded.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 6 June 2019 Resolved
Prove proper operation of lazarette bilge alarm.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 June 2019
Resolution: Vessel's crew corrected wiring issue with alarm, and proved operation.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018 Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 June 2019
Resolution: Verified in VIVS
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 June 2018 Resolved
Porvide proper mouting for for the following loosley installed items: PW head tank & piping, steering piping, helium bottle, F/O strainers, battery boxes, and bait pump.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 5 July 2018
Construction/Loadline › Structures › Manhole
Issued 6 June 2018 Resolved
Provide a keeper chain for the WTHs on deck
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 July 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 June 2018 Resolved
Provide proper install for loose/unsupported/open ended electrical wiring in the lazerette, engineroom, fwd bunkroom, storage closet fwd.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 5 July 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 May 2017 Resolved
Pneumatic switch outside of engine compartment would not shut down engine room machinery. Switch was corroded causing failure.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 9 May 2017
Resolution: New switch installed by fire technician Sergio.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 May 2017 Resolved
Provide current light list.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 13 July 2017
Resolution: Current light list provided.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 9 May 2017 Resolved
Provide current tide tables and currents
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 13 July 2017
Resolution: Tide tables provided.
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 May 2017 Resolved
Provide lids for batteries.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 9 May 2017
Resolution: Provides lids for batteries.
Fire Fighting › Fire Pumps › Capacity
Issued 9 May 2017 Resolved
Provide working gauge for fire pump.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 13 July 2017
Resolution: Gauge provided.
Documentation › Certificates/Documents › Permit, Other
Issued 7 June 2016 Resolved
Provide marine radio operators permit for each licensed master onboar.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 28 June 2016
Resolution: Marine operators permits onboard
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 June 2016 Resolved
Provide radio safetey certificate onboard the vessel
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 28 June 2016
Resolution: Radio Safety Certificate is now onboard.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 June 2016 Resolved
Renew buoyant lifeline on upper portside life ring buoy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 28 June 2016
Resolution: Life line renewed
Navigation › Piloting/Steering › Marine Charts
Issued 7 June 2016 Resolved
Provide updated charts for the operating area of the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 28 June 2016
Resolution: Updated charts provided
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 June 2016 Resolved
Provide current copy or extracts of the U.S. Coast Pilot
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 28 June 2016
Resolution: Current copy of coast pilot now onboard.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 June 2016 Resolved
Provide current copy or extracts of the Coast Light list for operating area.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 28 June 2016
Resolution: light list now onboard
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 June 2016 Resolved
Provide tide/tidal current table for the vessel's operating area.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 28 June 2016
Resolution: Tidal currents tables now onboard

Casualty record · 8

15 May 2002Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 1719787
23 July 2006Routine · role: Involved in a Marine Investigation (non-casualty) · 1 injured · activity 2739284
1 June 2008Routine · role: Involved in a Marine Casualty · activity 3322808
7 July 2008Routine · role: Involved in a Marine Casualty · activity 3263811
7 August 2013Routine · role: Involved in a Marine Casualty · activity 4745077
21 August 2013Routine · role: Involved in a Marine Casualty · activity 4693541
9 October 2020Routine · role: Involved in a Marine Casualty · activity 7115190
22 April 2023Routine · role: Involved in a Marine Casualty · activity 7686287
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CHEROKEE GEISHA (2002–2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.