FORT HAMILTON is a 1949 passenger vessel (inspected). The Coast Guard has recorded 8 inspections since 2016, most recently in October 2019, along with 14 deficiencies and 2 casualty investigations between 2011 and 2013.
Records from 2011 to 2019. Most recent: inspection, 22 October 2019.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)70.0 ft × 36.1 ft × 6.2 ft
Registered tonnagegross 99 / net 77
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTATEN ISLAND, NY, UNITED STATES · built 1949
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton 77 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 8
22 October 2019Attraction Vessel Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6839353
16 October 2019Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6835376
15 January 2019Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6610394
1 October 2018Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6552040
22 January 2018Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6341571
17 January 2017Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6069745
5 July 2016Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5930391
30 March 2016Drydock Extension
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5843665
At each initial and subsequent inspection for certification, the Marine Inspector shall view the vessel afloat and shall satisfy himself as to the condition of the hull structure.
- 4"x6" cutout located on the deck in the port side of the lazarette
- 10"x2" cutout located on the deck on the outboard side of the stbd hull in the lazarette
- hole exists on the forward hull of the forepeak rubrail
- waste tank discharge piping penetrating the deck in the lazarette does not have a proper coupling
- hole exists in the deck separating the stbd engine room void and the bar.
46 CFR 176.25-5
Action required: 60 - Rectify deficiencies prior to movement
Due 15 January 2019
Resolved 26 February 2019
Resolution: All cutouts properly cropped and renewed. New coupling installed for waste tank discharge piping.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 15 January 2019Resolved
Outlet boxes shall be securely fastened. Outlet box in bar area not securely fastened, 46 CFR 111.75-35
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2019
Resolved 29 January 2019
Resolution: Outlet box permanently secured to the bulkhead
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 15 January 2019Resolved
All electrical installations shall be to the satisfaction of the [name withheld] end cable coming off subpanel in engine room to be removed or in junction box, 46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2019
Resolved 29 January 2019
Resolution: Dead-ended wires removed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 January 2019Resolved
Drills will be held as specified by the inspector at each inspection. Man overboard and firefighting drills not conducted. Drills must ve conducted prior to carrying passengers, 46 CFR 176.808(g)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2019
Resolution: Conducted sat fire and MOB drills
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 January 2019Resolved
All vessels shall be provided with not less than two avenues of escape from all areas where the crew may be normally employed. Emergency escape hatch for the engine room was frozen, 46CFR177.15-1
Action required: 10 - Deficiency Rectified
Due 15 January 2019
Resolved 15 January 2019
Resolution: Hatch worked free
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 January 2019Resolved
Penetrations in watertight bulkheads must have means to make them watertight. Penetrations near the watertight door between the engine room and shaft space were not watertight. 46 CFR 171.114
Action required: 10 - Deficiency Rectified
Due 15 January 2019
Resolved 15 January 2019
Resolution: Penetrations filled with Fire Stop.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 January 2019Resolved
Visual and audible alarm must be provided at the operating station to indicate a high water level in each of the spaces listed: lazarette, shaft void, engine room, and forepeak. High water alarms in the shaft void and engine room were not operating. 46 CFR 182.530
Action required: 10 - Deficiency Rectified
Due 15 January 2019
Resolved 15 January 2019
Resolution: Bilge alarm connections repaired; alarms operational
Engineering › Sea-water System (primary cooling) › Pump
Issued 22 January 2018Resolved
Repair wasted section of SSDG raw water overboard in wing ballast port side engine room prior to carrying passengers, 46CFR182.710.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2018
Resolution: 01FEB18: Attended VSL to clear the reaming outstanding 835s from annual inspection. New section of SSDG raw water pipe installed. Through hull had metallic pipe plug installed. Engine room egress was labeled properly.
New section of SSDG raw water pipe
Repair or cap overboard overboard pipe port side engine room prior to carrying passengers; 46CFR176.610.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2018
Resolution: Through hull had metallic pipe plug installed.
Construction/Loadline › Structures › Scuttle
Issued 22 January 2018Resolved
Escape hatch was frozen and needs to be marked do not block, hatch was opened corrected on the spot but still needs to be marked by 05FEB18; 46CFR185.30-15.
Action required: 705 - Other - as specified
Due 5 February 2018
Resolved 1 February 2018
Resolution: Engine room egress was labeled properly.
7 November 2011Routine · role: Involved in a Marine Casualty · activity 4189759
24 July 2013Routine · role: Suspected to be in Violation of Law or Reg · activity 4664499
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
FORT WARREN (2011–2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.