Records from 1985 to 2019. Most recent: inspection, 22 October 2019.
Inspection history · 62
22 October 2019
Attraction Vessel Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6839353
16 October 2019
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6835376
15 January 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6610394
1 October 2018
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6552040
22 January 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6341571
17 January 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6069745
5 July 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5930391
30 March 2016
Drydock Extension
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5843665
15 October 2015
Examination of Repairs · COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5742351
7 May 2014
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4852271
1 May 2014
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4848241
19 March 2014
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4819566
19 July 2012
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4383811
26 February 2010
DAPI Audit
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3687720
21 January 2010
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3667276
23 October 2008
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3350131
18 October 2007
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3082116
4 June 2007
Hull Examination · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2951388
28 September 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2789290
26 October 2005
Re-Inspection · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2522658
25 May 2005
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2367646
14 October 2004
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2220614
2 July 2003
Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1833289
9 June 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1850185
14 May 2003
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1792424
9 August 2001
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1440525
18 July 2001
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1070799
26 March 2001
Plan Review "T" Boat
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1427993
20 June 1997
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 778309
10 December 1996
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1097674
29 May 1996
Deficiency Check · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1189795
24 May 1996
Deficiency Check · MARPOL Annex V Examination · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1188586
6 October 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 877899
11 July 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 883370
31 May 1995
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1187200
14 June 1994
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1326438
2 June 1994
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 860506
9 May 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 858618
16 March 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 105288
10 August 1993
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 848522
2 July 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 659503
18 June 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 53415
18 June 1993
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1153654
25 June 1992
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1268012
12 June 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 957616
3 April 1992
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1264737
27 June 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1252840
7 May 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 941882
4 June 1990
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1215440
17 May 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 934820
12 May 1989
Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1346058
26 April 1989
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1034220
18 August 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1345227
18 August 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1352972
14 April 1988
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1205715
13 January 1988
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1318734
18 November 1987
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1024299
17 April 1987
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1007995
22 April 1986
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1003221
14 April 1986
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1307713
25 February 1985
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 975432
16 January 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1284219
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 January 2019
Resolved
At each initial and subsequent inspection for certification, the Marine Inspector shall view the vessel afloat and shall satisfy himself as to the condition of the hull structure.
- 4"x6" cutout located on the deck in the port side of the lazarette
- 10"x2" cutout located on the deck on the outboard side of the stbd hull in the lazarette
- hole exists on the forward hull of the forepeak rubrail
- waste tank discharge piping penetrating the deck in the lazarette does not have a proper coupling
- hole exists in the deck separating the stbd engine room void and the bar.
46 CFR 176.25-5
Action required: 60 - Rectify deficiencies prior to movement
Due 15 January 2019
Resolved 26 February 2019
Resolution: All cutouts properly cropped and renewed. New coupling installed for waste tank discharge piping.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 15 January 2019
Resolved
Outlet boxes shall be securely fastened. Outlet box in bar area not securely fastened, 46 CFR 111.75-35
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2019
Resolved 29 January 2019
Resolution: Outlet box permanently secured to the bulkhead
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 15 January 2019
Resolved
All electrical installations shall be to the satisfaction of the [name withheld] end cable coming off subpanel in engine room to be removed or in junction box, 46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2019
Resolved 29 January 2019
Resolution: Dead-ended wires removed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 January 2019
Resolved
Drills will be held as specified by the inspector at each inspection. Man overboard and firefighting drills not conducted. Drills must ve conducted prior to carrying passengers, 46 CFR 176.808(g)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2019
Resolution: Conducted sat fire and MOB drills
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 January 2019
Resolved
All vessels shall be provided with not less than two avenues of escape from all areas where the crew may be normally employed. Emergency escape hatch for the engine room was frozen, 46CFR177.15-1
Action required: 10 - Deficiency Rectified
Due 15 January 2019
Resolved 15 January 2019
Resolution: Hatch worked free
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 January 2019
Resolved
Penetrations in watertight bulkheads must have means to make them watertight. Penetrations near the watertight door between the engine room and shaft space were not watertight. 46 CFR 171.114
Action required: 10 - Deficiency Rectified
Due 15 January 2019
Resolved 15 January 2019
Resolution: Penetrations filled with Fire Stop.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 January 2019
Resolved
Visual and audible alarm must be provided at the operating station to indicate a high water level in each of the spaces listed: lazarette, shaft void, engine room, and forepeak. High water alarms in the shaft void and engine room were not operating. 46 CFR 182.530
Action required: 10 - Deficiency Rectified
Due 15 January 2019
Resolved 15 January 2019
Resolution: Bilge alarm connections repaired; alarms operational
Engineering › Sea-water System (primary cooling) › Pump
Issued 22 January 2018
Resolved
Repair wasted section of SSDG raw water overboard in wing ballast port side engine room prior to carrying passengers, 46CFR182.710.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2018
Resolution: 01FEB18: Attended VSL to clear the reaming outstanding 835s from annual inspection. New section of SSDG raw water pipe installed. Through hull had metallic pipe plug installed. Engine room egress was labeled properly.
New section of SSDG raw water pipe
Construction/Loadline › Penetrations › Pipe Flange
Issued 22 January 2018
Resolved
Repair or cap overboard overboard pipe port side engine room prior to carrying passengers; 46CFR176.610.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2018
Resolution: Through hull had metallic pipe plug installed.
Construction/Loadline › Structures › Scuttle
Issued 22 January 2018
Resolved
Escape hatch was frozen and needs to be marked do not block, hatch was opened corrected on the spot but still needs to be marked by 05FEB18; 46CFR185.30-15.
Action required: 705 - Other - as specified
Due 5 February 2018
Resolved 1 February 2018
Resolution: Engine room egress was labeled properly.
Lifesaving › Lifejacket/PFD (Type III) › Condition
Issued 22 January 2018
Resolved
Found (01) kapok jacket leaking, replaced on the spot with type III; 46CFR180.71.
Action required: 705 - Other - as specified
Due 22 January 2018
Resolved 22 January 2018
Resolution: corrected on the spot
Lifesaving › Lifejacket/PFD (Type III) › Marking
Issued 22 January 2018
Resolved
Name of vessel on life jackets, (06) needed names and corrected on the spot; 46CFR185.604.
Action required: 705 - Other - as specified
Due 22 January 2018
Resolved 22 January 2018
Resolution: corrected on the spot.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 January 2017
Resolved
Found two wasted rails on second deck port side FWD near pilot house. Repair or replace.
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 24 February 2017
Resolution: Deck rails were welded Satisfactorily.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 January 2017
Resolved
Found window on main deck port side cracked. Replace.
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 24 February 2017
Resolution: Window was replaced on port side.
Construction/Loadline › Hull › Hull Plating
Issued 15 October 2015
Resolved
Make temp repair to hole in hull on port bow. Permanent repairs to be made at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 26 October 2015
Resolution: Section was cropped and renewed and tested to satisfaction of attending MI.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 May 2014
Resolved
Sea-water pipe from generator cooling is wasted and leaking excessive water. Make repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2014
Resolution: repaired pipe, tested sat.
Engineering › Bilge Water Management System › Piping
Issued 7 May 2014
Resolved
Bilge piping in Void #2 is wasted. Repair and demonstrate proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2014
Resolution: Repaired bilge, tested sat.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 7 May 2014
Resolved
Multiple holes in sewage tank. Make repairs
Due 21 May 2014
Resolved 16 June 2014
Resolution: Repaired, tested.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 19 July 2012
Resolved
Repair or replace inoperative "E" lights iwo engine room stairs.
Due 26 July 2012
Resolved 20 July 2012
Resolution: "E" light replaced sat.
Engineering › Steering Gear System › Cable
Issued 19 July 2012
Resolved
grease sheves for rudder cable.
Due 26 July 2012
Resolved 20 July 2012
Resolution: Sheeves greased sat.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 July 2012
Resolved
Place open wires for main engine start button into an approved junction box.
Due 26 July 2012
Resolved 20 July 2012
Resolution: Start button wires were plced in a correct electrical junction box.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 26 February 2010
Resolved
Results of pre-employment tests are not confirmed as negative prior to entry into safety sensitive positions as required by 46 CFR 16.210(a). All future tests must be confirmed negative. In addition pre-employment drug test results were not available for inspection. Pre-employment results for all employees (or proof that employees have worked for the company longer than 5 years) shall be provided.
Action required: 705 - Other - as specified
Due 28 March 2010
Resolved 30 March 2010
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 26 February 2010
Resolved
Drug testing background checks have not been completed as required by 49 CFR 40.25. All background checks for the upcoming summer season shall be provided.
Action required: 705 - Other - as specified
Due 28 March 2010
Resolved 30 March 2010
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 26 February 2010
Resolved
Company policy is not displayed as required by 46 CFR 16.410(a). Company policy will be displayed (or stored in a binder in pilothouse if display is not practical) on all vessels. No follow up is required.
Action required: 705 - Other - as specified
Due 26 February 2010
Resolved 26 February 2010
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 26 February 2010
Resolved
Crewmembers and supervisors have not received Employee Assistance Program training as required by 46 CFR 16.401(b). Plan for completing training with all crewmembers and supervisors will be submitted by 5 March 2010.
Action required: 705 - Other - as specified
Due 28 March 2010
Resolved 17 June 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 23 October 2008
Resolved
Replace bungee cord with proper mounting bracket
Action required: 705 - Other - as specified
Due 30 November 2008
Resolved 23 October 2008
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 23 October 2008
Resolved
Replace faulty float switch
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 October 2008
Resolved 10 November 2008
Construction/Loadline › Structures › Superstructure
Issued 23 October 2008
Resolved
Repair wasted hand rail, stbd side, aft on fan tail.
Action required: 705 - Other - as specified
Due 30 November 2008
Resolved 10 November 2008
Operations/Management › Passenger Operations › Safety Orientation
Issued 23 October 2008
Resolved
Install max passengers allowed placard for top deck
Action required: 705 - Other - as specified
Due 30 November 2008
Resolved 10 November 2008
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 18 October 2007
Resolved
Replace two adult life jackets.
Due 18 October 2007
Resolved 1 November 2007
Resolution: Replaced sat.
Electrical › Electric Generation Source (service) › Panelboard
Issued 18 October 2007
Resolved
replace power light on control panel.
Due 18 October 2007
Resolved 1 November 2007
Resolution: replaced sat.
Construction/Loadline › Structures › Door
Issued 28 September 2006
Resolved
Replace broken and rotted window frames to forward main deck doors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 27 October 2006
Construction/Loadline › Structures › Deck Plating
Issued 26 October 2005
Resolved
Make permanent repairs to cracked deck plating on fantail.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2006
Resolved 2 May 2006
Resolution: Work completed and tested, sat.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 26 October 2005
Resolved
Provide locking device on sewage overboard valves (2).
Action required: 705 - Other - as specified
Due 10 November 2005
Resolved 7 November 2005
Resolution: Corrected
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 26 October 2005
Resolved
Provide 17 new adult PFD's. Passenger carriage reduced accordingly until completed.
Action required: 705 - Other - as specified
Due 10 November 2005
Resolved 7 November 2005
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 October 2005
Resolved
Repair inop/unused water heater or disconnect electrical power and remove wire.
Action required: 705 - Other - as specified
Due 10 November 2005
Resolved 7 November 2005
Resolution: Corrected
Construction/Loadline › Structures › Deck Plating
Issued 26 October 2005
Resolved
Make permanent repairs in the forward void to properly tie in all overhead structural members to adjacent deck plating. Repairs shall be to the satisfaction of attending CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2006
Resolved 2 May 2006
Resolution: Work completed as per proposal submitted 15 Feb 2006.
Construction/Loadline › Penetrations › Weld
Issued 25 May 2005
Resolved
Reweld aft sink overboard thru hull located on the starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 1 June 2005
Construction/Loadline › Hull › Transverse Frame
Issued 25 May 2005
Resolved
Crop and renew wasted section of #2 bottom frame in the forward peak compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 1 June 2005
Construction/Loadline › Penetrations › Valve Flange
Issued 25 May 2005
Resolved
Secure valve handle for generator inlet sea valve located in the engine room.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 1 June 2005
Construction/Loadline › Hull › Longitudinal Frame
Issued 25 May 2005
Resolved
Crop and renew two sections of longitudinal stiffeners in the lazarette as marked..
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 1 June 2005
Construction/Loadline › Hull › Bottom Plating
Issued 25 May 2005
Resolved
Gauge bottom plating in the lazarette along the port side.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 1 June 2005
Resolution: Reviewed gauging of bottom plating in the lazarette and found satisfactory.
Construction/Loadline › Hull › Transverse Frame
Issued 25 May 2005
Resolved
Crop and renew wasted section of bottom frame #2 next to the MSD holding tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 1 June 2005
Construction/Loadline › Hull › Bottom Plating
Issued 25 May 2005
Resolved
Install insert bottom plating in the engine room port side as marked (3' x 4' section).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 1 June 2005
Resolution: Examined of newly installed insert plate in the engine room. Found fit up welding satisfactory. Also witnessed a satisfactory hose test.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 14 October 2004
Resolved
Secure electrical panel box located in the wheel house.
Due 28 October 2004
Resolved 28 October 2004
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 October 2004
Resolved
Secure electrical junction box feeding the power for the fish tank.
Due 28 October 2004
Resolved 28 October 2004
Documentation › Certificates/Documents › Stability Letter
Issued 9 June 2003
Resolved
Provide stability letter and post it under glass.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 20 June 2003
Resolution: Posted stability letter on bridge under glass.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 9 June 2003
Resolved
Remove invalid station bill.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 20 June 2003
Resolution: Invalid station bill has been removed.
Communications › Internal Communications System
Issued 9 June 2003
Resolved
Provide comms between pilothouse and emergency steering station.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 20 June 2003
Resolution: Provided and tested comms between pilothouse and emergency steering station.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 9 June 2003
Resolved
Prior to carrying passengers provide proper portable fire extinguishers as per COI.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 20 June 2003
Resolution: Provided proper number of portable fire extinguishers as per COI.
Fire Fighting › Fire Pumps › Power Source
Issued 9 June 2003
Resolved
Prior to carrying passengers repair electric fire pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 20 June 2003
Resolution: Tested Fire pump, tested sat.
Fire Fighting › Fire Main › Valves
Issued 9 June 2003
Resolved
Prior to carrying passengers repair fire pump discharge valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 20 June 2003
Resolution: Tested fire pump discharge valve, test sat.
Communications › Alarms/Indicators
Issued 9 June 2003
Resolved
Prior to carrying passengers label bilge alarm system. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 20 June 2003
Resolution: Properly labeled bilge alarm system and tested sat.
Stability › Watertight Integrity
Issued 9 June 2003
Resolved
Remove sluice valve from lazarette to tank space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 20 June 2003
Resolution: Removed sluice valve from lazarette to tank space.
Engineering › Bilge Water Management System
Issued 9 June 2003
Resolved
Install high level bilge sensor in lazarette.
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 20 June 2003
Resolution: Tested high level bilge sensor in lazarett, tested sat.
Navigation › Piloting/Steering › Magnetic Compass
Issued 9 June 2003
Resolved
Repair magnetic compass.
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 20 June 2003
Resolution: Repaired magnetic compass.
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 June 2003
Resolved
Properly install battery on bridge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 20 June 2003
Resolution: Properly installed battery on bridge.
Navigation › Collision/Grounding Avoidance
Issued 9 June 2003
Resolved
Provide 12" bell onboard the vessel.
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 20 June 2003
Resolution: Provided 12" bell.
Communications › Audible Communications
Issued 9 June 2003
Resolved
Install P.A. system on bridge.
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 20 June 2003
Resolution: Installed and tested P.A. system on bridge.
Communications › Visual Communication
Issued 9 June 2003
Resolved
Provide RPM gauge for MDE.
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 20 June 2003
Resolution: Provided RPM gauge for MDE.
Navigation › Collision/Grounding Avoidance
Issued 9 June 2003
Resolved
Make up anchor ready for letting go.
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 20 June 2003
Resolution: Anchor is ready for letting go.
Engineering › Fuel Oil Service System › Valve
Issued 9 June 2003
Resolved
Label emergency fuel shutoff valves.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 20 June 2003
Resolution: Labeled emergency fuel shutoff valves.
Construction/Loadline › Structures › Deck Plating
Issued 14 May 2003
Resolved
Crop extensive wastage areas in overhead in forepeak and lazarette to allow thorough inspection of doubled weather-deck plating. Topside of plating not accessible for inspection due to application of a permanent deck coating similar to concrete.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2005
Resolved 25 May 2005
Construction/Loadline › Structures › Rake
Issued 14 May 2003
Resolved
Crop and renew extensive wastage areas in old sumps located in overheads in forward end of forepeak and aft end of aftpeak to allow thorough inspection of hidden bulkheads
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2005
Resolved 25 May 2005
Lifesaving
Issued 9 August 2001
Resolved
Prove proper operation of light on life ring buoy.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Construction/Loadline
Issued 9 August 2001
Resolved
Label bilge alarms in pilothouse.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Electrical
Issued 9 August 2001
Resolved
Remove or replace all broken neon lighting.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Accommodation/Occupational Safety
Issued 9 August 2001
Resolved
Make proper repairs to pilothouse windows.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Electrical
Issued 9 August 2001
Resolved
Remove or end in junction box all dead-end wires including those aft of pilothouse, on pilothouse dash, and in engine room.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Accommodation/Occupational Safety
Issued 9 August 2001
Resolved
Properly secure rail door on door rail.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Navigation
Issued 9 August 2001
Resolved
Provide deviation table for magnetic compass.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Electrical
Issued 9 August 2001
Resolved
Provide light fixture for light above main diesel engine.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Construction/Loadline
Issued 9 August 2001
Resolved
Provide check valve for bilge system in aft lazarette.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Lifesaving
Issued 9 August 2001
Resolved
Properly stencile or placard emergency escape route in engine room.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Accommodation/Occupational Safety
Issued 9 August 2001
Resolved
Prove proper operation of men's and ladies' bathroom facilities.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Electrical
Issued 9 August 2001
Resolved
Prove proper operation of emergency lighting.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Engineering
Issued 9 August 2001
Resolved
Provide additional clamp for raw water suction on generator.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Unknown
Issued 9 August 2001
Resolved
Properly secure all refrigeration machinery in engine room.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Lifesaving
Issued 9 August 2001
Resolved
Complete man overboard drill to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Electrical
Issued 9 August 2001
Resolved
Properly blank open breakers in kitchen electrical panel.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Electrical
Issued 9 August 2001
Resolved
Properly pack or blank open holes in panel above HVAC disconnect, aft engine room bulkhead wire penetrations, and deck in aft lazarette along stbd side.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Unknown
Issued 9 August 2001
Resolved
Clear emergency escape passage from engine room.
Condition: Unknown
Due 15 August 2001
Resolved 10 August 2001
Construction/Loadline
Issued 9 August 2001
Resolved
Prove proper operation of both bilge pumps.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Construction/Loadline
Issued 9 August 2001
Resolved
Provide accesible metallic valves on all through hulls below main deck.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Navigation
Issued 9 August 2001
Resolved
Make proper repairs to steering gear.
Condition: Unknown
Due 15 August 2001
Resolved 10 August 2001
Accommodation/Occupational Safety
Issued 9 August 2001
Resolved
Mount automatic door closer on engine room door.
Condition: Unknown
Due 15 August 2001
Resolved 10 August 2001
Unknown
Issued 9 August 2001
Resolved
Prove proper operation of public address and hailing system.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Construction/Loadline
Issued 29 May 1996
Resolved
CROP OUT AND RENEW SECTION OF TRANSVERSE FRAME WHERE WASTED, IN LAZARETTE ABOVE STEERING GEAR POST.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Accommodation/Occupational Safety
Issued 29 May 1996
Resolved
PROPERLY SECURE BOW LOADING DOOR THAT IS NO LONGER IN USE.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Accommodation/Occupational Safety
Issued 29 May 1996
Resolved
CROP OUT AND RENEW BOTTOM SILL OF BOW LOADING DOOR WHERE WASTED.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Accommodation/Occupational Safety
Issued 29 May 1996
Resolved
REPLACE BROKEN WINDOW ON THE MAIN DECK, STARBOARD SIDE.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Construction/Loadline
Issued 29 May 1996
Resolved
PROVIDE PROPER STRAINER ON BILGE PIPE SUCTION IN STARBOARD VOID SPACE ADJACENT TO ENGINE SPACE.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Fire Fighting
Issued 24 May 1996
Resolved
REMOVE FROM VESSEL CO2 EXTINGUISHER THAT HAS BROKEN NOZZLE HANDLE AND EXPIRED HYDROTEST DATE.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Electrical
Issued 24 May 1996
Resolved
PROVE PROPER OPERATION OF LIGHTING IN FOREPEAK COMPARTMENT.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Documentation
Issued 24 May 1996
Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 24 May 1996
Resolved 12 June 1996
Documentation
Issued 24 May 1996
Resolved
PROVIDE VALID FCC CERTIFICATES INCLUDING STATION LICENSE, RADIOTELEPHONY CERT. AND OPERATOR'S LICENSE.
Condition: Unknown
Due 24 May 1996
Resolved 12 June 1996
Documentation
Issued 24 May 1996
Resolved
REMOVE ALL OLD INSPECTION DECALS FROM PILOT HOUSE WINDOW.
Condition: Unknown
Due 24 May 1996
Resolved 12 June 1996
Fire Fighting
Issued 24 May 1996
Resolved
PROVIDE AN ADDITIONAL BII HAND PORTABLE FIRE EXTINGUISHER ON THE SECOND DECK ACCOMMODATION SPACE, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 24 May 1996
Resolved 12 June 1996
Fire Fighting
Issued 24 May 1996
Resolved
PROVIDE SPANNER WRENCHES AT EACH FIRE FIGHTING STATION PRIOR TO OPERATION.
Condition: Unknown
Due 24 May 1996
Resolved 12 June 1996
Lifesaving
Issued 24 May 1996
Resolved
PROVIDE RETROREFLECTIVE TAPE ON ALL 3 RING LIFE BUOYS.
Condition: Unknown
Due 24 May 1996
Resolved 12 June 1996
Lifesaving
Issued 24 May 1996
Resolved
PROVIDE A PROPERLY PAINTED AND LABELED CONTAINER FOR THE DISTRESS SIGNALS.
Condition: Unknown
Due 24 May 1996
Resolved 12 June 1996
Navigation
Issued 24 May 1996
Resolved
PROVE PROPER OPERATION, REMOVE FROM VESSEL OR REPLACE INOPERABLE VHF-FM RADIO STARBOARD SIDE IN PILOT HOUSE.
Condition: Unknown
Due 24 May 1996
Resolved 12 June 1996
Electrical
Issued 24 May 1996
Resolved
PROPERLY REPAIR EXPOSED WIRING IN PILOT HOUSE ON THE AFT BULKHEAD - CENTERLINE.
Condition: Unknown
Due 24 May 1996
Resolved 12 June 1996
Fire Fighting
Issued 24 May 1996
Resolved
PROFESSIONALLY SERVICE ALL HAND PORTABLE FIRE EXTINGUISHERS, PRIOR TO OPERATION.
Condition: Unknown
Due 24 May 1996
Resolved 12 June 1996
Lifesaving
Issued 24 May 1996
Resolved
RENEW RING BUOY GRAB LINES, PRIOR TO OPERATION.
Condition: Unknown
Due 24 May 1996
Resolved 12 June 1996
Lifesaving
Issued 24 May 1996
Resolved
RENEW RETROREFLECTIVE TAPE ON ADULT AND CHILD JACKETS AS NOTED DURING EXAMINATION.
Condition: Unknown
Due 24 May 1996
Resolved 12 June 1996
Accommodation/Occupational Safety
Issued 24 May 1996
Resolved
PROVIDE LIGHT IN OUTLET AT AFT LADDER LEADING TO UPPER DECK.
Condition: Unknown
Due 24 May 1996
Resolved 12 June 1996
Construction/Loadline
Issued 24 May 1996
Resolved
PROPERLY LABEL FOREPEAK ISOLATION VALVE.
Condition: Unknown
Due 24 May 1996
Resolved 12 June 1996
Construction/Loadline
Issued 24 May 1996
Resolved
MAKE PERMANENT REPAIRS TO AFT LADDER RAILING.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Lifesaving
Issued 24 May 1996
Resolved
PROVIDE APPROVED AND PROPER WATERLIGHT FOR RING BUOY, PRIOR TO OPERATION.
Condition: Unknown
Due 24 May 1996
Resolved 12 June 1996
Electrical
Issued 24 May 1996
Resolved
PROVIDE ADEQUATE GLOBE LIGHT COVERS ON UPPER DECK LIGHTING.
Condition: Unknown
Due 24 May 1996
Resolved 12 June 1996
Fire Fighting
Issued 24 May 1996
Resolved
PROVE PROPER OPERATION OF ENGINE DRIVEN JABSCO FIRE/BILGE PUMP, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 24 May 1996
Resolved 12 June 1996
Construction/Loadline
Issued 24 May 1996
Resolved
REMOVE ALL OIL FROM ENGINE ROOM BILGES.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Construction/Loadline
Issued 31 May 1995
Resolved
REINSTALL LOWER KEEPERS FOR PORT AND STARBOARD LOADING DOORS.
Condition: Unknown
Due 31 May 1995
Resolved 31 May 1995
Accommodation/Occupational Safety
Issued 31 May 1995
Resolved
REPLACE TWO FRACTURED WINDOWS AT STARBOARD AFT END ACCOMMODATION SPACE.
Condition: Unknown
Due 31 May 1995
Resolved 31 May 1995
Accommodation/Occupational Safety
Issued 31 May 1995
Resolved
PROVE PROPER OPERATION OF MSD FEED PUMP.
Condition: Unknown
Due 31 May 1995
Resolved 31 May 1995
Lifesaving
Issued 2 June 1994
Resolved
LABEL LIFE PRESERVER STOWAGE AREA FOR ADULT AND CHILD LIFE PRESERVERS, INDICATING TYPE (I.E. ADULT OR CHILD) AND AMOUNT.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Engineering
Issued 2 June 1994
Resolved
REPLACE MAIN ENGINE TEMPERATURE GAUGE ON BRIDGE.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Accommodation/Occupational Safety
Issued 2 June 1994
Resolved
REPLACE 2 BROKEN SEATS ON UPPER DECK.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Accommodation/Occupational Safety
Issued 2 June 1994
Resolved
REPLACE CRACKED WINDOW ON STARBOARD SIDE MAIN DECK.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Engineering
Issued 2 June 1994
Resolved
INSTALL LAGGING ON MAIN ENGINE STARBOARD EXHAUST WHERE MISSING._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 June 1994
Resolved 3 June 1994
Engineering
Issued 2 June 1994
Resolved
INSTALL PROPER WIRE CONNECTORS ON MAIN ENGINE START SWITCH WIRING IN WAY OFWIRE NUTS.
Condition: Unknown
Due 2 June 1994
Resolved 3 June 1994
Engineering
Issued 2 June 1994
Resolved
INSTALL FLAME SCREENS ON PORT AND STARBOARD FUEL TANK VENTS.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Engineering
Issued 2 June 1994
Resolved
LABEL EMERGENCY FUEL SHUTOFF STATION.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Accommodation/Occupational Safety
Issued 2 June 1994
Resolved
REPLACE CRACKED WINDOW PORT SIDE MAIN DECK.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Construction/Loadline
Issued 18 June 1993
Resolved
PRIOR TO OPERATION, PROVE THE ABILITY TO DEWATER THE FOREPEAK AND STORAGE COMPARTMENT FORWARD OF THE ENGINE ROOM.
Condition: Unknown
Due 18 June 1993
Resolved 22 June 1993
Documentation
Issued 18 June 1993
Resolved
PRIOR TO OPERATING MORE THAN 1000 FEET FROM LAND, PROVIDE A VALID FCC RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 19 June 1993
Resolved 6 August 1993
Lifesaving
Issued 18 June 1993
Resolved
THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION AND ABANDON SHIP IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 18 August 1993
Resolved 6 August 1993
Construction/Loadline
Issued 18 June 1993
Resolved
REPLACE MISSING BILGE STRAINER IN SHAFT ROOM.
Condition: Unknown
Due 2 July 1993
Resolved 6 August 1993
Construction/Loadline
Issued 18 June 1993
Resolved
ON OR BEFORE NEXT DRYDOCK BUT NO LATER THAN 31 OCT 93, INSTALL HULL MARKINGS IN ACCORDANCE WITH 46 CFR 185.30-3.
Condition: Unknown
Due 18 June 1993
Resolved 18 June 1993
Navigation
Issued 18 June 1993
Resolved
PRIOR TO OPERATION, PROVIDE AN ANCHOR LIGHT IN ACCORDANCE WITH THE NAVIGATIONAL RULES OF THE ROAD.
Condition: Unknown
Due 24 June 1993
Resolved 24 June 1993
Construction/Loadline
Issued 18 June 1993
Resolved
REPLACE MISSING BILGE STRAINER IN FORE PEAK.
Condition: Unknown
Due 2 July 1993
Resolved 6 August 1993
Construction/Loadline
Issued 18 June 1993
Resolved
REMOVE OIL FROM ENGINE ROOM BILGE.
Condition: Unknown
Due 24 June 1993
Resolved 24 June 1993
Lifesaving
Issued 18 June 1993
Resolved
PROVIDE AN ADDITIONAL 10 ADULT AND 4 CHILD'S PFD'S.
Condition: Unknown
Due 2 July 1993
Resolved 6 August 1993
Lifesaving
Issued 25 June 1992
Resolved
PROVIDE THIRD 24" ORANGE RING BUOY AS PER 46 CFR 180.30.5._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 June 1992
Resolved 25 June 1992
Lifesaving
Issued 25 June 1992
Resolved
CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, AND ABANDONSHIP PRIOR TO CARRYING PASSENGERS. DRILL TO BE CONDUCTED IN THE PRESENCE OF A U.S. COAST GUARD INSPECTOR._x001C_ _x001C_
Condition: Unknown
Due 25 June 1992
Resolved 25 June 1992
Construction/Loadline
Issued 25 June 1992
Resolved
REMOVE DIESEL FUEL FROM STARBOARD MIDSHIPS WING/BALLAST TANK AND REPAIR LEAK TO STARBOARD FUEL TANK VENT PIPE WITHIN STARBOARD MIDSHIPS WING/BALLAST TANK._x001C_ _x001C_
Condition: Unknown
Due 25 June 1992
Resolved 25 June 1992
Construction/Loadline
Issued 25 June 1992
Resolved
REMOVE AND PLUG UNUSED/OLD SEA STRAINER IN ENGINE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 June 1992
Resolved 25 June 1992
Electrical
Issued 25 June 1992
Resolved
PROVE OPERATION OR REMOVE 32 VOLT D.C. 2.5 KW BATTERY CHARGER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 June 1992
Resolved 25 June 1992
Accommodation/Occupational Safety
Issued 25 June 1992
Resolved
PROVIDE PUBLIC ADDRESS SYSTEM FOR PROPER CREW COMMUNICATIONS AND EMERGENCY SITUATIONS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 June 1992
Resolved 25 June 1992
Accommodation/Occupational Safety
Issued 25 June 1992
Resolved
PROVIDE EMERGENCY CHECKOFF LISTS FOR MAN OVERBOARD, ABANDONSHIP, FIRE AS PER 46 CFR 185.25.1._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 June 1992
Resolved 25 June 1992
Fire Fighting
Issued 25 June 1992
Resolved
HYDROSTATICLY TEST ONE BII FIRE EXTINQUISHER LOCATED IN BAR AREA OF MAIN DECK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 June 1992
Resolved 25 June 1992
Fire Fighting
Issued 25 June 1992
Resolved
PROVE PROPER OPERATION OF BOTH FIRE/BILGE PUMPS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 June 1992
Resolved 25 June 1992
Construction/Loadline
Issued 3 April 1992
Resolved
CROP AND RENEW DAMAGED/HOLED RUBRAIL AS NEEDED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 April 1992
Resolved 1 June 1992
Construction/Loadline
Issued 3 April 1992
Resolved
INSTALL STOP VALVE IN BILGE PIPING TO FORE PEAK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Accommodation/Occupational Safety
Issued 3 April 1992
Resolved
PROVIDE PLUG FOR SLUICE PIPE FROM AFTER STEERING COMPARTMENT INTO SHAFT ALLEY COMPARTMENT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Accommodation/Occupational Safety
Issued 3 April 1992
Resolved
REPLACE PVC PIPING IN MSD OVERBOARD DISCHARGE PIPING IN WAY OF EXHAUST SYSTEM IN LAZARETTE. PIPING NEEDS TO METALLIC IN WAY OF EXHAUST PIPE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Construction/Loadline
Issued 3 April 1992
Resolved
REMOVE EXCESS OIL FROM BILGES IN ENGINE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1992
Resolved 25 June 1992
Construction/Loadline
Issued 3 April 1992
Resolved
VEE OUT AND REWELD HOLE IN WELD IN WAY OF STEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 April 1992
Resolved 1 June 1992
Construction/Loadline
Issued 3 April 1992
Resolved
CROP AND RENEW HOLED BULWARK IN AFT STARBOARD SIDE MAIN DECK AREA._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Construction/Loadline
Issued 3 April 1992
Resolved
CROP AND RENEW SIDE SHELL PLATING STARBOARD SIDE AFT APPROX 30"X72" IN THE LAZARETTE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 April 1992
Resolved 1 June 1992
Construction/Loadline
Issued 3 April 1992
Resolved
CONDUCT HULL GUAGINGS OF BOX KEEL, TRANSOM, AND RANDOM AREAS OF REMAINING ORIGINAL HULL PLATING. PROVIDE RESULTS/REPORT OF GUAGINGS FOR DETERMINATIONOF EXTENT OF HULL PLATE RENEWAL REQUIRED._x001C_ _x001C_
Condition: Unknown
Due 3 April 1992
Resolved 1 June 1992
Construction/Loadline
Issued 3 April 1992
Resolved
REPAIR/REPLACE BILGE PIPING WHERE WASTED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Construction/Loadline
Issued 27 June 1991
Resolved
INSTALL A WARNING LIGHT IN THE PILOT HOUSE TO INDICATE IF EACH OF THE 3 DOORS IN WATERTIGHT BULKHEADS ARE OPEN OR CLOSED. THIS REQUIREMENT TO BE COMPLETED TO THE SATISFACTION OF [name withheld] PRIOR TO 27 JUNE 1991.
Condition: Unknown
Due 27 June 1991
Resolved 27 June 1991
Electrical
Issued 26 April 1989
Resolved
A GLOBE AND LIGHT BULB WERE MISSING FROM A LIGHT FIXTURE LEAVING A BARE SOCKET.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Fire Fighting
Issued 26 April 1989
Resolved
DURING THE OPERATION OF THE FIRE MAIN SYSTEM THE FIRE HOSE ON THE UPPER DECK BURST.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Unknown
Issued 26 April 1989
Resolved
POLLUTION PLACARD WAS MISSING.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Fire Fighting
Issued 14 April 1988
Resolved
REPLACE BROKEN VALVE MARKED NO. 5 UNDER PRESSURE GUAGE IN FIRE MAIN . ALSO REPAIR LEAKING 45 DEGREE FITTING IN FIRE MAIN AT FRONT OF MAIN ENGINE.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Fire Fighting
Issued 17 April 1987
Resolved
MAKE PERMANENT REPAIR TO THE HOLED SECTION OF THE FIREMAIN AT THE FIRST PIPING CONNECTION DOWNSTREAM OF THE PUMP DISCHARGE.
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Engineering
Issued 17 April 1987
Resolved
LABEL THE EMERGENCY FUEL SHUTOFFS.
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Navigation
Issued 17 April 1987
Resolved
MAKE PERMANENT REPAIRS TO STEERING CABLE FAIRLEAD PULLEYS AND REMOVE SLACK FROM QUADRANT CABLES.
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Electrical
Issued 17 April 1987
Resolved
INSTALL ANTI-VIBRATION BRACING ON BATTERY CHARGING GENERATOR F.O. DROP PIPEAND REPLACE UNACCEPTABLE FUEL OIL SUPPLY AND RETURN HOSES ON GENERATOR WITHAPPROVED HOSES.
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Construction/Loadline
Issued 14 April 1986
Resolved
CAP DRAIN LEADING FROM AFT STEERING TO THE ENGINEROOM
Condition: Unknown
Due 14 April 1986
Resolved 14 April 1986
Fire Fighting
Issued 14 April 1986
Resolved
REPAIR GUAGE AND GASKET ON FIRE PUMP
Condition: Unknown
Due 14 April 1986
Resolved 14 April 1986
Construction/Loadline
Issued 14 April 1986
Resolved
PROVIDE AN ADDITIONAL FIXED BILGE PUMP
Condition: Unknown
Due 14 April 1986
Resolved 14 April 1986
Lifesaving
Issued 14 April 1986
Resolved
PROVIDE 6 RED AND 6 ORANGE DISTRESS FLARES
Condition: Unknown
Due 14 April 1986
Resolved 14 April 1986
Fire Fighting
Issued 14 April 1986
Resolved
PROVIDE 2 PROPERLY SERVICED B-II FIRE EXTINGUISHERS
Condition: Unknown
Due 14 April 1986
Resolved 14 April 1986
Lifesaving
Issued 14 April 1986
Resolved
PROVIDE 45 COAST GUARD APPROVED ADULT PFDS, PASSENGERS REDUCED BY 45 UNTIL JACKETS ARE PROVIDED
Condition: Unknown
Due 14 April 1986
Resolved 14 April 1986
Lifesaving
Issued 14 April 1986
Resolved
PROVIDE 3 COAST GUARD APPROVED RING BUOYS
Condition: Unknown
Due 14 April 1986
Resolved 14 April 1986
Construction/Loadline
Issued 14 April 1986
Resolved
REPAIR DOGS ON AFT WATER TIGHT DOOR
Condition: Unknown
Due 14 April 1986
Resolved 14 April 1986
Construction/Loadline
Issued 14 April 1986
Resolved
FREE-UP ESCAPE HATCH LEADING FROM ENGINEROOM
Condition: Unknown
Due 14 April 1986
Resolved 14 April 1986