MAURY USCG vessel records
← All vessels

BOW CLIPPER

BOW CLIPPER is a 1995 tank ship. The Coast Guard has recorded 19 inspections since 2016, most recently in February 2024, along with 7 deficiencies and 2 operational controls.

Records from 2016 to 2024. Most recent: inspection, 3 February 2024.

Built
1995
Last inspected
3 February 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9047518
V7A5039
426833
Flag
MARSHALL ISLANDS
Maury page id
psix-426833

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 8 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it23197 - Convention (Subpart B), Gross Ton
12176 - Convention (Subpart B), Net Ton
37221 - Dead Weight, Metric Ton
48264 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 19

3 February 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7856595
23 October 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7812708
2 December 2022 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7603059
2 July 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7242454
23 June 2021 Special
Type not classified · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7234115
25 February 2021 Special
Type not classified · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7146478
19 January 2021 PSC B · COC-CHEM Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7125052
24 May 2019 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6692796
24 April 2019 ISPS II Exam · PII Safety Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6669138
17 April 2019 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6664302
7 May 2018 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6404070
12 May 2017 COC-CHEM & TVE Renew · ISPS II Exam · Administrative Inspection · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6138188
10 January 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6068523
27 September 2016 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6010990
24 July 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5956624
21 July 2016 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5943307
16 May 2016 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5876272
9 February 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5812015
3 February 2016 ISPS III Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5808675

Deficiency record · 7

11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 19 January 2021 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Rescue boat davit manual fast and slow hoisting mechanism not working as designed. SOLAS III/20, 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2021
Resolution: Received class report stating satisfactory repairs and testing were made. Tested manual hoisting, hydraulic power, and accumulator (pressure verified).
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 19 January 2021 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Lifeboat engine was unable to start when inspected by [name withheld] were found to have low voltage. Batteries charged to working order. SOLAS 74 III/20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 January 2021
Resolution: Batteries charged and placed in proper service. New batteries were also ordered.
Pollution Prevention/Response › Response Equipment › Protective Clothing
Issued 12 May 2017 Resolved
One out of three chemical suits showed sign of deterioration around face seal-area; failing to produce adequate protection.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2017
Resolved 16 May 2017
Resolution: Received class report from DNV. Vessel replaced worn chemical suit with a new one.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 12 May 2017 Resolved
Incinerator electrical door interlock switch failure
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 16 May 2017
Resolution: Received class report from DNV. Vessel repaired interlock system on the incinerator. Vessel conducted operational test and was successful.
Electrical › Electric Generation Source (service) › Generator
Issued 16 May 2016 Resolved
A main source of electrical power shall be sufficient for all services required by SOLAS II-1/40 and the main soruces of electrical power shall consist of two generating sets. The starboard generator is inoperable. 74 SOLAS (97) II-1/41.1.1 60ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2016
Resolution: Received Class report, technician report, and attestation from Master and Chief Engineer attesting to the repairs.
Engineering › Fuel Oil Service System › Pump
Issued 3 February 2016 Resolved
Precautions shall be taken to prevent any oil that may escape under pressure from any pump, filter, or heater from coming into contact with heated surfaces. The number 2 and 4 cylinders fuel oil pumps were leaking fuel from seals. 74SOLAS(97)II-2/15.2.4
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2016
Resolved 8 February 2016
Resolution: Received DNV GL Class report attesting to the proper repairs. See attached doc.
Lifesaving › Lifeboat Equipment › Radar Transponder
Issued 3 February 2016 Resolved
Before the ship leaves port, and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. Both SARTs batteries have passed expiration date. 74SOLAS(14)III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2016
Resolved 8 February 2016
Resolution: Received DNV GL Class report attesting to new batteries in SART. See attached doc.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.