Records from 2000 to 2020. Most recent: inspection, 8 October 2020.
Inspection history · 61
8 October 2020
COC-CHEM & TVE Renew · MARPOL Annex VI Survey · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7073692
2 February 2019
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6618960
29 June 2018
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6459528
6 June 2018
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6436216
6 June 2018
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6436510
25 May 2018
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6423278
25 May 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6450327
4 March 2018
Administrative Inspection · ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6362393
3 February 2012
VRP Review
Administrative · Commandant (CG-CVC) · Activity 4237674
1 August 2011
COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4098481
28 January 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3934716
27 January 2011
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3938872
27 January 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3945922
25 January 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3930924
13 November 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3890342
16 September 2010
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3851571
27 March 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3699940
18 January 2010
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3665518
18 January 2010
COE-Offshore
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3665684
18 January 2010
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3673180
14 July 2009
Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3534569
11 May 2009
COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3472038
18 April 2009
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3455653
31 July 2008
ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3283432
24 July 2007
MARPOL Annex II Examination · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · COC-CHEM Annual · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3005621
12 July 2007
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2992513
12 June 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2959065
3 June 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2950195
22 May 2007
MARPOL Annex II Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2937408
22 August 2006
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2756221
27 July 2006
Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2726773
26 May 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2659685
18 May 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2652871
16 May 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2650579
27 September 2005
ISPS II Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2502541
16 May 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2363981
28 April 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2344825
8 March 2005
COC-CHEM Annual
Type not classified · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2306039
8 March 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2306092
2 January 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2269910
2 August 2004
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2153873
4 June 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2089447
2 June 2004
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2088351
3 September 2003
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1895824
14 July 2003
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1844634
25 March 2003
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1762824
18 November 2002
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1706940
4 November 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1701186
1 November 2002
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1699425
24 August 2002
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1667163
1 August 2002
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1655524
28 June 2002
Security Inspection · Certificate of Compliance
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1639228
15 April 2002
Security Inspection · In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1604980
25 January 2002
In-Service Inspection · Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1492567
21 November 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 295606
28 September 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 294263
17 July 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 291984
12 March 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 288249
9 August 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 171754
8 August 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 280911
8 August 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1053525
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 2 February 2019
Resolved
Chemical tankers and gas carriers carrying cargoes emitting toxic vapors or gases shall carry in lieu of totally enclosed lifeboats complying with the requirements of section 4.8 of the code. PSCO observed air supply hose holed on P/S lifeboat, rendering the lifeboat air support system inoperative.
SOLAS 74a (2001) Cons III/ 31.1.6 LSA code 4.8
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 February 2019
Resolution: Crew replaced hose, witnessed sat pressure test.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 6 June 2018
Resolved
The company should ensure that the policy is implemented and maintained at all levels of the organization, both ship-based and shore-based. Vsl has had inoperable fuel tank high level alarm since Aug 2017 and was reported to the company but has not received a replacement. Vsl did not have an alternate procedure during internal transfer for the crew when fuel tank hi lvl alarm or a critical equipment is inoperable. These factors may have prevented the spill incident. ISM 2.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 June 2018
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 6 June 2018
Resolved
In addition to the requirements in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration. Vessel has had inoperable fuel tank high-level alarm since Aug 2017. 74 SOLAS (2004) CH II-1/3.1
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 June 2018
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 25 May 2018
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to...other hazards.
The vessel experienced an equipment failure while transiting the navigable waters of the United States which adversely affected its maneuverability and posed a hazard to vessels and infrastructure along the Houston Ship Channel.
Submit for review a Classification Society report to [email withheld] attesting to the cause of the equipment failure, that authorized temporary or permanent repairs have been completed, and that the vessel's full and normal maneuverability has been restored. 74SOLAS (2004 CONS) II-1/26
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2018
Resolution: Received satisfactory Class Report rectifying the deficiency.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 25 May 2018
Resolved
The company should identify equipment and technical systems the sudden operational failure of which may result in hazardous situations. The safety management system should provide for specific measures aimed at promoting the reliability of such equipment or systems.
The vessel experienced an equipment failure while transiting the navigable waters of the United States which adversely impacted its fitness and capability to safely maneuver the Houston Ship Channel.
Submit evidence to [email withheld] detailing how this hazardous situation was reported to the company, investigated, and analyzed with the objective of improving safety, including the implementation of corrective action and measures intended to prevent recurrence (as detailed and required in ISM A/9). 74SOLAS (2014 CONS.) IX/3.1 REF. ISM A/9 & 10.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2018
Resolved 31 May 2018
Resolution: Received satisfactory Class Report rectifying the deficiency.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 1 August 2011
Resolved
0330 Water closets shall be provided with ample flush of water, available at all times and independently controlled. Toilets did not flush upon several attempts.
33USC 1223(b)
Action required: 705 - Other - as specified
Due 8 August 2011
Resolved 16 October 2011
Resolution: Received, reviewed and accepted class report from ABS stating water closets are in working order.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 August 2011
Resolved
0950 All electrical apparatus shall be so constructed and installed to not cause injury when handled or touched. Galley electrical outlet was supplied with power from a spliced extension cord plugged into another outlet.
SOLAS 2001 CH II-1 REG 45.1.3
Due 1 August 2011
Resolved 1 August 2011
Resolution: Spliced extension cord was removed and outlet was placed into normal/correct condition.
Lifesaving › Lifeboat › Propulsion Engine
Issued 1 August 2011
Resolved
0610 Vessel's crew was unable to start the port lifeboat engine. All lifesaving appliances shall be in working order and ready for immediate use.
SOLAS 2009 CH III REG 20.2
LSA CH IV 4.4.6.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2011
Resolution: The port lifeboat boat engine was started after cleaning of battery terminals.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 1 August 2011
Resolved
0710 As per fire control plan, various doors enclosing spaces of Class "A" divisions shall be self-closing. Multiple doors required to be self-closing did not self close.
SOLAS 2001 CH II-2 Reg 20.1
Due 1 August 2011
Resolved 1 August 2011
Resolution: Non self-closing fire doors were made shelf-closing.
Deck/Cargo › Cargo Stowage › General
Issued 1 August 2011
Resolved
2199 Harmful substances shall be properly stored and secured to minimize the hazards to ship’s crew and marine environment. Vessel had multiple tank cleaning chemicals stored on deck in a non-designated stowage location.
Due 1 August 2011
Resolved 1 August 2011
Resolution: The tank cleaning chemicals stored on deck was removed and placed in proper locations.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1.1-Documentation Routine Vessel Inspection
Issued 1 August 2011
Resolved
Vessels crew did not properly record routine inspections as required by EPA vessel general permit. the last entry found was Januarty 2011. VGP 4.1.1.1
[name withheld] [phone withheld]
MSU Texas City, Texas
Action required: 705 - Other - as specified
Resolved 16 October 2011
Resolution: Received, reviewed and accepted VGP inspection reports from vessel.
Construction/Loadline › Hull › Bottom Plating
Issued 27 January 2011
Resolved
Vessel experienced a grounding while in the Mississippi River.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2011
Resolved 28 January 2011
Resolution: Received, reviewed and accepted class report from ABS stating the underwater hull plating remains to be examined. All tanks and bilges were sounded and compared to previous report and no ingress was noted.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 14 July 2009
Resolved
0610 - 7 portside lifeboat rations and 9 starboard side lifeboat rations were not in airtight packaging as required by code. SOLAS 97 Consol Ed Chpt III 8.12 & LSA Chpt III 4.4.8.12.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 15 July 2009
Resolution: 15 Jul 2009 - Received Captains attestation and Receipt for delivery of 20 replacement lifeboat food rations.
01 Deficiency Cleared 00 Deficiencies remain outstanding
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 31 July 2008
Resolved
Vessel was found with three fire or explosion hazards in engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2008
Resolved 1 August 2008
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 24 July 2007
Resolved
The emergency generator failed to operate as required. During the course of the inspection the vessel's crew was unable to start the emergency generator. After trying for 20 minutes the emergency generator started but could not be restarted on a regular basis.
Action required: 705 - Other - as specified
Resolved 26 July 2007
Resolution: Received class report from ABS satisfying requirement.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 July 2006
Resolved
Fire [name withheld] indicates that life rings fitted with buoyant lifeline, also must be fitted with self ignition light. There were no self igniting lights.
Action required: 705 - Other - as specified
Due 27 August 2006
Resolved 22 August 2006
Resolution: Received email with attachment of class report attesting to corrective action taken.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 27 July 2006
Resolved
The nonmetallic cargo hoses for hazardous materials were not marked properly.
Action required: 705 - Other - as specified
Due 27 August 2006
Resolved 10 December 2006
Resolution: Found to be corrected.
Navigation › Piloting/Steering › Gyro Compass
Issued 16 May 2005
Resolved
Vessel request inbound deviation for inoperable Gyro Compass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2005
Resolution: Received report from technician attesting to proper operation of vessel Gyro.
Electrical › Electrical Distribution System (service)
Issued 28 June 2002
Resolved
Vessel ground detection system, cant not be tested. Conduct operational test of system and provided test procedures. Have the issuing authority of the safety equipment certificate send a report attesting to system operation to Coast Guard. LEGACY COMPONENT DESC: Ground Detection
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 July 2002
Resolved 1 August 2002
Resolution: Received class report attesting to installation of the test buttons, for the Ground Detection System for the ship''s main electrical switchboards.